Lead_Report_Warehouse_15.pdf

PDF 70 KB Posted

Attached to
Paint the interior walls of offices and adjacent areas of Buildings
Solicitation number
SP330017B0014
Issued by

About this file

Lead Report Warehouse 15

View the file

Other files

File Type Posted
Amendment_0004_to_SP330017B0014.pdf PDF
Updated_Attachment_7_Drawings.pdf PDF
Updated_Attachment_6_Specifications.pdf PDF
Amendment_0003.pdf PDF
Lead_Report_Building_255.pdf PDF
Amendment_0002.pdf PDF
Lead_Report_Warehouse_16.pdf PDF
Lead_Report_Building_201.pdf PDF
Lead_Report_Warehouse_19.pdf PDF
Lead_Report_Warehouse_22.pdf PDF
Lead_Report_Warehouse_14.pdf PDF
Lead_Report_Building_247.pdf PDF
Lead_Report_Warehouse_21.pdf PDF
Lead_Report_Warehouse_28.pdf PDF
Updated_SF1449_Solicitation_SP330017B0014.pdf PDF
Lead_Report_Building_231.pdf PDF
Lead_Report_Warehouse_20.pdf PDF
Updated_Attachment_6_-_Specifications.pdf PDF
Lead_Report_Warehouse_13.pdf PDF
Site_Visit_Attendee_List.pdf PDF
Updated_Attachment_6_-_Specifications.pdf PDF
Updated_SF1449_Solicitation_SP330017B0014.pdf PDF
Amendment_0001.pdf PDF
Attachment_1_-__SF24_-_Bid_Bond.pdf PDF
Attachment_3_-__SF25A_(Payment_Bond).pdf PDF
Attachment_4_Construction_Wage_Determination.pdf PDF
Attachment_6_Specifications.pdf PDF
Attachment_5_Environmental_Checklist.pdf PDF
SF1442_Solicitation.pdf PDF
Attachment_8_Submittal_Register_.pdf PDF
Attachment_7_Drawings.pdf PDF
Attachment_2_-__SF25_(Performance_Bond).pdf PDF
synopsis.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

XRF Lead Report_WH-15_ p.1

Defense Logistics Agency - San Joaquin Tracy, California

XRF Lead Evaluation

Date: 06 July 2017 Subject: Field Analysis for Suspect Lead Paint Bulk Sample Collected from the DLASJ Tracy, Warehouse 15

Evaluation

On 06 July 2017, field testing for the presence of Lead was performed on the primary structural coatings (paints) identified on the surfaces of the building materials at the DLASJ, Tracy, Warehouse 15. Robert Miller, Certified Industrial Hygienist, and Lonny Jones, Industrial Hygiene Technician, performed the field sample analysis utilizing a handheld Innov-X Systems, Alpha Series, X-Ray Fluorescence (XRF) Spectrometer. Prior to this sampling event the calibration of the XRF instrument was verified by performing an analysis of a National Institute of Standards & Technology (NIST), Reference Material. The field testing data for Warehouse 15 is provided in Table 1 of this report.

Table 1 Sample Number

Coating / Paint Description Lead Concentration

0706-15-01 Bubble Interior: White on concrete walls Non-Detect (ND) 0706-15-02 Bubble Interior: Blue on concrete walls ND 0706-15-03 Bubble Interior: White on interior downspouts ND 0706-15-04 Bubble Interior: Blue on metal pedestrian door frames >5.0 mg/cm2 0706-15-05 Bubble Interior: Blue on pedestrian door frames in Safety

Office

ND

0706-15-06 Bubble Interior: White on drywall in Safety Office ND 0706-15-07 Bubble Interior: White on walls in Breakroom ND 0706-15-08 Bubble Interior: White on walls in Supervisors Office >5.0 mg/cm2 0706-15-09 Bubble Interior: White on walls in restrooms ND 0706-15-10 Warehouse Interior: Coated steel I-Beams >5.0 mg/cm2 0706-15-11 Warehouse Interior: White on concrete walls ND 0706-15-12 Warehouse Interior: Blue on concrete walls ND 0706-15-13 Warehouse Interior: Yellow on steel barriers for former fire doors >5.0 mg/cm2

0706-15-14 Warehouse Interior: Yellow on metal trims on frames of former fire doors

>5.0 mg/cm2

0706-15-15 Warehouse Interior: Safety yellow on concrete floor near former fire doors

ND

0706-15-16 & 0706-15-19

Warehouse Interior: Safety yellow on concrete floor along east and west interior walls

ND

XRF Lead Report_WH-15_ p.2

0706-15-17 Warehouse Interior: Safety yellow on concrete floor around conveyors

ND

0706-15-18 Warehouse Interior: Yellow on handrails along stairs in Section 5

ND

0706-15-20 Exterior: Safety yellow on concrete docks >5.0 mg/cm2 0706-15-21 &

0706-15-30 Exterior: Yellow on handrails >5.0 mg/cm2

0706-15-22 Exterior: Gray on concrete walls ND 0706-15-23 Exterior: Gray on metal pedestrian door frames ND 0706-15-24 Exterior: Blue on square downspouts ND 0706-15-25 Exterior: Light blue on round steel downspouts 1.37 mg/cm2 0706-15-26 Exterior: Yellow on stair risers (significant blistering) 1.32 mg/cm2 0706-15-27 Exterior: Yellow on metal trim on docks >5.0 mg/cm2 0706-15-28 Exterior: Yellow on wood bumpers >5.0 mg/cm2 0706-15-29 Exterior: Yellow on metal trim on bumpers >5.0 mg/cm2 0706-15-31 Exterior: Blue on metal pedestrian doors >5.0 mg/cm2 0706-15-32 Exterior: Blue on metal pedestrian door frames ND 0706-15-33 Exterior: Safety yellow strip on concrete docks (significant blistering) >4.5 mg/cm2

0706-15-34 Exterior: Safety yellow on concrete dock around conveyors 2.50 mg/cm2 0706-15-35 Exterior: Blue on metal frames of overhead doors >5.0 mg/cm2

-- Exterior: Gray paint on steel beams at 45o angles located above canopies

Assumed Lead- Containing

-- Exterior: Gray coated steel I-beams beneath canopies Assumed Lead- Containing

-- Exterior: Blue trim along canopies Assumed Lead- Containing

-- Exterior: Light blue on fascia beneath gutters Assumed Lead- Containing

-- Exterior: Light blue on window frames Assumed Lead- Containing

Discussion

The field testing of the coatings associated with the DLASJ Tracy, Warehouse 22, did identify Lead concentrations that are described in Table 1 of this report. The Federal OSHA 29 CFR

1926.62 and 29 CFR 1910.1025 Standards and California OSHA 8CCR 1532.1, and Title 17 CCR Standards regulate exposures to materials with any detectable amount of Lead.

Recommendations

• Any activity that may include the disturbance of Lead-containing materials must be performed within the regulations set forth in Federal OSHA 29 CFR 1926.62, 29 CFR

1910.1025 and California OSHA 8CCR 1532.1, and Title 17 CCR Standards.

• Disposal of any building materials that are coated with Lead-containing paint must be disposed of per the requirements of the DS-FJ Installation Support Environmental Office.

Robert Miller, CIH Certified Industrial Hygienist