Lead_Report_Warehouse_22.pdf

PDF 68 KB Posted

Attached to
Paint the interior walls of offices and adjacent areas of Buildings
Solicitation number
SP330017B0014
Issued by

About this file

Lead Report Warehouse 22

View the file

Other files

File Type Posted
Amendment_0004_to_SP330017B0014.pdf PDF
Updated_Attachment_7_Drawings.pdf PDF
Updated_Attachment_6_Specifications.pdf PDF
Amendment_0003.pdf PDF
Lead_Report_Building_255.pdf PDF
Amendment_0002.pdf PDF
Lead_Report_Warehouse_16.pdf PDF
Lead_Report_Building_201.pdf PDF
Lead_Report_Warehouse_19.pdf PDF
Lead_Report_Warehouse_14.pdf PDF
Lead_Report_Building_247.pdf PDF
Lead_Report_Warehouse_21.pdf PDF
Lead_Report_Warehouse_28.pdf PDF
Updated_SF1449_Solicitation_SP330017B0014.pdf PDF
Lead_Report_Building_231.pdf PDF
Lead_Report_Warehouse_15.pdf PDF
Lead_Report_Warehouse_20.pdf PDF
Updated_Attachment_6_-_Specifications.pdf PDF
Lead_Report_Warehouse_13.pdf PDF
Site_Visit_Attendee_List.pdf PDF
Updated_Attachment_6_-_Specifications.pdf PDF
Updated_SF1449_Solicitation_SP330017B0014.pdf PDF
Amendment_0001.pdf PDF
Attachment_1_-__SF24_-_Bid_Bond.pdf PDF
Attachment_3_-__SF25A_(Payment_Bond).pdf PDF
Attachment_4_Construction_Wage_Determination.pdf PDF
Attachment_6_Specifications.pdf PDF
Attachment_5_Environmental_Checklist.pdf PDF
SF1442_Solicitation.pdf PDF
Attachment_8_Submittal_Register_.pdf PDF
Attachment_7_Drawings.pdf PDF
Attachment_2_-__SF25_(Performance_Bond).pdf PDF
synopsis.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

XRF Lead Report_WH-22_ p.1

Defense Logistics Agency - San Joaquin Tracy, California

XRF Lead Evaluation

Date: 06 July 2017 Subject: Field Analysis for Suspect Lead Paint Bulk Sample Collected from the DLASJ Tracy, Warehouse 22

Evaluation

On 06 July 2017, field testing for the presence of Lead was performed on the primary structural coatings (paints) identified on the surfaces of the building materials at the DLASJ, Tracy, Warehouse 22. Robert Miller, Certified Industrial Hygienist, and Lonny Jones, Industrial Hygiene Technician, performed the field sample analysis utilizing a handheld Innov-X Systems, Alpha Series, X-Ray Fluorescence (XRF) Spectrometer. Prior to this sampling event the calibration of the XRF instrument was verified by performing an analysis of a National Institute of Standards & Technology (NIST), Reference Material. The field testing data for Warehouse 22 is provided in Table 1 of this report.

Table 1 Sample Number

Coating / Paint Description Lead Concentration

0706-22-01 Exterior: Steel support for canopy Non-Detect (ND) 0706-22-02 Exterior: Light gray on concrete wall, Section 1 >1.0 mg/cm2 0706-22-03 Exterior: Yellow on handrail by stairs > 5.0 mg/cm2 0706-22-04 Exterior: Yellow on stairs to Box Shop entrance ND 0706-22-05 Exterior: Yellow on stair risers to dock ND 0706-22-06 Exterior: Blue on metal pedestrian door >5.0 mg/cm2 0706-22-07 Exterior: Blue on downspout 2.60 mg/cm2 0706-22-08 Exterior: Yellow on metal dock trim >5.0 mg/cm2 0706-22-09 Exterior: Yellow on wooden bumpers on dock >5.0 mg/cm2

0706-22-10 & 0706-22-33

Exterior: Yellow on floor around conveyors, on exterior dock and interior floor

1.17 mg/cm2

0706-22-11 Exterior: Blue on overhead door trim >5.0 mg/cm2 0706-22-12 Exterior: Light blue on concrete walls ND

-- Exterior: Blue paint on the steel beams at 450 angles located above canopy

Assumed Lead- Containing

-- Exterior: Gray coated steel I-beams beneath canopy, significant blistering

Assumed Lead- Containing

-- Exterior: Light gray throughout underside of canopy, significant blistering

Assumed Lead- Containing

0706-22-13 Bubble Interior: White on concrete walls ND 0706-22-14 Bubble Interior: Blue on concrete walls ND 0706-22-15 Bubble Interior: Blue on restroom door frames ND

XRF Lead Report_WH-22_ p.2

0706-22-16 Bubble Interior: White on interior downspouts ND 0706-22-17 Bubble Interior: Blue on metal pedestrian doors ND 0706-22-18 Bubble Interior: White on drywall in Breakroom ND 0706-22-19 Bubble Interior: White on concrete walls in Breakroom ND 0706-22-20 Bubble Interior: White on door frames in Offices ND 0706-22-21 Bubble Interior: White on walls in South Breakroom ND 0706-22-22 Bubble Interior: White on restroom walls ND 0706-22-23 Warehouse Interior: Coated steel I-Beams >5.0 mg/cm2 0706-22-24 Warehouse Interior: White on concrete walls 1.58 mg/cm2 0706-22-25 Warehouse Interior: Blue on concrete walls 2.60 mg/cm2 0706-22-26 Warehouse Interior: Fire red on concrete floors ND 0706-22-27 Warehouse Interior: Yellow on metal trims on former fire door frames >5.0 mg/cm2

0706-22-28 & 0706-22-31

Warehouse Interior: Black on concrete floors ND

0706-22-29 Warehouse Interior: Red on fire risers ND 0706-22-30 Warehouse Interior: Safety yellow on concrete floors ND 0706-22-32 Warehouse Interior: Green on concrete wall by former fire doors

ND

Discussion

The field testing of the coatings associated with the DLASJ Tracy, Warehouse 22, did identify Lead concentrations that are described in Table 1 of this report. The Federal OSHA 29 CFR

1926.62 and 29 CFR 1910.1025 Standards and California OSHA 8CCR 1532.1, and Title 17 CCR Standards regulate exposures to materials with any detectable amount of Lead.

Recommendations

• Any activity that may include the disturbance of Lead-containing materials must be performed within the regulations set forth in Federal OSHA 29 CFR 1926.62, 29 CFR

1910.1025 and California OSHA 8CCR 1532.1, and Title 17 CCR Standards.

• Disposal of any building materials that are coated with Lead-containing paint must be disposed of per the requirements of the DS-FJ Installation Support Environmental Office.

Robert Miller, CIH Certified Industrial Hygienist