SOW OPTION 4 Non Resident Chambers 233 CD DWGS 2021 03 17 (1).pdf
PDF 3 MB Posted
- Solicitation number
- 47PE0221R0011
About this file
This solicitation seeks general construction services for renovations to resident and non-resident judges' chambers at the Elbert P. Tuttle Federal Building in Atlanta, Georgia. The General Services Administration intends to award a firm-fixed-price contract to a single contractor through competitive negotiation using lowest price technically acceptable procedures. Renovations include two resident judges' chambers and four non-resident judges' chambers for the Court of Appeals. The estimated price range for construction is between $1 million and $5 million. The contract is set aside for small businesses only.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Room name
1t
A101
SIM
ROOM INDICATOR
DETAIL INDICATOR
TO BE REMOVED (DEMO SHEETS)
EXISTING TO REMAIN
NEW
HIDDEN FEATURES LINE
CENTER LINE
2 HOUR RATED WALL
1 HOUR RATED WALL
PATH OF EGRESS
EGRESS DOOR
EXIT EXIT SIGN
NORTH INDICATOR
BUILDING SECTION INDICATOR
WALL SECTION INDICATOR BREAK LINE INDICATOR
WINDOW TYPE TAG INDICATOR
2 41 8
GRAPHIC SCALE, 1/8" = 1'-0"
DOOR TAG INDICATOR
ELEVATION INDICATOR
CENTER LINE
06 41 00.PL KEYNOTE INDICATOR
(SEE PROJECT MANUAL)
0 GRID LINE
A101
SIM
INTERIOR ELEVATION INDICATOR
CALLOUT INDICATOR
DRAWING TITLE
DIMENSION LINE
1 View Name A101 1/8" = 1'-0"
A101
SIM
A101
SIM
A101
1 Ref
Re f
Re f
1 Ref
2ND FL
CALLED
NORTH
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
CIVIL ENGINEER:
MEP ENGINEER:STRUCTURAL ENGINEER:
ARCHITECT:
Occupancy Type:
Construction Type:
Fire Suppression:
Project Name:Key Plan: Project Information:
Project Team:
Drawing List:
C:\Users\HWA17\Documents\1855_Tuttle 233 _ R20_octavian@houserwalker.com.rvt
11/16/2020 3:33:36 PM
G001
11/18/20 100% Construction Documents
COVER SHEET
OT
GW
Johnson Spellman & Assoc.
350 Research Court Suite 130 Peachtree Corners, GA 30092 678.336.5427
Westside Engineering 5525 Interstate North Parkway- Suite 200 Atlanta, GA 30328 404.965.1287
Houser Walker Architecture 1819 Peachtree Rd NE Suite 102 Atlanta, GA 30309 404.633.4264
Nonresident Chambers Renovation - Ch. 233 Elbert P. Tuttle Court of Appeals 56 Forsyth Street NW Atlanta, GA
Existing, Business
Existing 2B (IBC) ; Type II (LSC)
Existing, Sprinklered
56 Forsyth Street Atlanta, Georgia
NXXXXXXX
Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Nonresident Chambers Renovations
Nonresident Chambers 233
Number Sheet Name 11 /1
8/
C
D s
C ur re nt
R ev isi on
G GENERAL
G001 COVER SHEET O
G002 GENERAL NOTES, LIFE SAFETY & KEYNOTE LIST O
A ARCHITECTURAL
A020 DOOR, WINDOW TYPES AND SCHEDULES O
A100 CHAMBER 233 - DEMO AND NEW O
A300 ENLARGED PLANS AND DETAILS O
A400 CHAMBER 233 CEILING PLAN O
A510 MILLWORK DETAILS O
AI ARCHITECTURAL INTERIORS
AI100 CHAMBER 233 - RCP + FURNITURE COORDINATION O
M MECHANICAL AND PLUMBING
MP001 HVAC LEGENDS AND ABBREVIATIONS O
MP100 HVAC DEMO PLAN O
MP200 HVAC NEW WORK PLAN O
MP400 HVAC DETAILS O
MP500 HVAC SCHEDULES, CONTROL SEQUENCES AND I/O SUMMARY O
E ELECTRICAL
E001 NOTES DETAILS AND LEGEND O
E100 RISER DIAGRAMS O
E101 PANEL SCHEDULES O
E200 ELECTRICAL PLAN 233 O
ED100 DEMOLITION PLAN 233 O
FP FIRE PROTECTION
FP200 FIRE PROTECTION O
Key: O = Current Issued NOT for Construction P = Previously Issued = Not Issued (blank) i = For Information Only
MPFP ENGINEER:ELECTRICAL ENGINEER :
Legend:
100% Construction Documents
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
05/06/19
Revision Number
Revision Date Revision Description
2ND FL KEY PLAN
CALLED
NORTH
DRINKING
FOUNTAIN
(EXIST.)
Law Clerk 233A
Law Clerk 233B
LIBRARY
Judges Chambers
Toilet 231A
40'-0" COMMON
PATH OF TRAVEL
63'-0" COMMON
PATH OF TRAVEL
EXISTING TO REMAIN
PATH OF EGRESS
EGRESS DOOR
EXIT EXIT SIGN
AREA OF NO WORK
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
C:\Users\HWA17\Documents\1855_Tuttle 233 _ R20_octavian@houserwalker.com.rvt
11/16/2020 3:33:40 PM
G002
11/18/20 100% Construction Documents
GENERAL NOTES, LIFE SAFETY & KEYNOTE
LIST
OT
GW
56 Forsyth Street Atlanta, Georgia
NXXXXXXX
Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Nonresident Chambers Renovations
Nonresident Chambers 233
1. THE CONTRACTOR SHALL MAINTAIN AT THE SITE FOR THE OWNER ONE COPY OF THE DRAWINGS, SPECIFICATIONS, ADDENDA, CHANGE ORDERS AND OTHER MODIFICATIONS, IN GOOD ORDER AND MARKED CURRENTLY TO INDICATE FIELD CHANGES AND SELECTIONS MADE DURING CONSTRUCTION, AND ONE COPY OF APPROVED SHOP DRAWINGS, PRODUCT DATA, SAMPLES, AND
SIMILAR REQUIRED SUBMITTALS.
2. THE CONTRACTOR SHALL PERFORM WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
3. THE DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY AND ARE TO BE UNDERSTOOD COMPREHENSIVELY.
ORGANIZATION AND ARRANGEMENT OF THE DRAWINGS AND/ OR SPECIFICATIONS INTO DIVISIONS, SECTIONS AND ARTICLES SHALL NOT CONTROL THE CONTRACTOR IN DIVIDING THE WORK AMONG SUBCONTRACTORS OR IN ESTABLISHING THE EXTENT OF WORK TO
BE PERFORMED BY ANY TRADE.
4. BECAUSE THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, THE CONTRACTOR SHALL, BEFORE STARTING EACH PORTION OF THE WORK, CAREFULLY STUDY AND COMPARE THE VARIOUS CONTRACT DOCUMENTS RELATIVE TO THAT PORTION OF THE WORK, SHALL TAKE FIELD MEASUREMENTS OF ANY EXISTING CONDITIONS RELATED TO THAT PORTION OF THE WORK, AND SHALL OBSERVE ANY CONDITION AT THE SITE AFFECTING IT. THESE OBLIGATIONS ARE FOR THE PURPOSE OF FACILITATING COORDINATION AND CONSTRUCTION BY THE CONTRACTOR AND ARE NOT FOR THE PURPOSE OF DISCOVERING ERRORS, OMISSIONS, OR INCONSISTENCIES IN THE CONTRACT DOCUMENTS. HOWEVER, THE CONTRACTOR SHALL PROMPTLY REPORT TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES OR OMISSIONS DISCOVERED BY OR MADE KNOWN TO THE CONTRACTOR AS REQUEST FOR INFORMATION.
5. DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION.
Contract Documents
Existing Conditions
1. EXISTING ADJACENT PORTIONS OF THE BUILDING ARE TO REMAIN OPERATIONAL THROUGHOUT CONSTRUCTION.
COORDINATE CONSTRUCTION ACTIVITIES AND PHASING WITH ARCHITECT, GSA COR, AND TENANT REPRESENTATIVE TO MINIMIZE
DISRUPTIONS TO OWNER’S OPERATIONS AND ACCESS, AND TO ENSURE SAFETY OF OCCUPANTS.
2. ATTENTION IS CALLED TO THE FACT THAT THIS PROJECT IS A RENOVATION OF AN EXISTING BUILDING. RENOVATION OF EXISTING BUILDINGS REQUIRE THOROUGH COORDINATION OF THE CONTRACT DOCUMENTS WITH THE EXISTING CONDITIONS. THE CONTRACTOR MUST VERIFY ALL RELEVANT EXISTING CONDITIONS, DIMENSIONS, AND DETAILS PRIOR TO BEGINNING
CONSTRUCTION.
3. ALL DRAWINGS AND DETAILS INCORPORATING EXISTING CONDITIONS ARE REPRESENTATIONS OF EXISTING CONDITIONS ONLY. THE CONTRACTOR SHALL VERIFY THE ACCURACY OF ACTUAL CONDITIONS AND COORDINATE WITH THE ARCHITECT ANY
DEVIATIONS OF THE DETAILS SO TO EXECUTE THE INTENT OF THE DRAWING OR DETAIL.
4. FIELD VERIFY EXISTING DIMENSIONS PRIOR TO ORDERING OR CUTTING MATERIALS.
5. CUTTING AND PATCHING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING, FITTING OR PATCHING REQUIRED TO COMPLETE THE WORK OR TO MAKE PARTS FIT TOGETHER PROPERLY. ALL AREAS REQUIRING CUTTING, FITTING AND PATCHING SHALL BE RESTORED TO THE CONDITION EXISTING PRIOR TO CUTTING, FITTING AND PATCHING.
6. REMOVE COMPLETELY MATERIALS AS INDICATED ON THE DRAWINGS AND AS REQUIRED FOR NEW CONSTRUCTION. EDGES AND FACES OF DEMOLISHED AREAS SHALL BE REPAIRED TO ACCEPT NEAT INSTALLATION OF NEW CONSTRUCTION OR FINISHES.
WHERE EXISTING MATERIALS ARE TO BE REPLACED, EXISTING MATERIALS, ADHESIVES, ETC. SHALL BE REMOVED AND EXPOSED SURFACES SHALL BE REPAIRED AS RECOMMENDED BY MANUFACTURER PRIOR TO INSTALLATION OF NEW MATERIALS.
7. PATCH ALL EXISTING HOLES AND VOIDS AND PATCH HOLES CAUSED BY THE REMOVAL OF EQUIPMENT, PIPING, CONDUIT, DUCT, GRILLS, ETC WITH MATERIALS MATCHING EXISTING.
8. WHERE FINISH SCHEDULE SHOWS EXISTING FINISHES TO REMAIN, THESE FINISHES TO BE REPAIRED AND/ OR EXTENDED TO BE
SEAMLESS WITH RENOVATED AREAS.
9. SURFACES OF NEW AND EXISTING FINISHES ARE TO MATCH IN COLOR, TEXTURE AND CONSISTENCY, UNLESS NOTED
OTHERWISE.
10. CONTRACTOR IS RESPONSIBLE FOR REROUTING ANY EXISTING CONDUITS, WIRING, PLUMBING AND PIPING AS REQUIRED TO ACHIEVE THE DESIRED LAYOUT AND DESIGN INTENT SHOWN. NEW REROUTING LOCATIONS SHALL BE CONCEALED WITHIN WALL. WHEN IT IS IMPOSSIBLE TO CONCEAL ITEMS, LOCATE ITEMS TIGHT AGAINST WALLS- ENCLOSE ITEMS WITH GYPSUM WALL
BOARD WITHOUT DISRUPTION OF SERVICE TO OTHER AREAS.
Other General Requirements
Modified Area:
1542 sf
Occupant Load: (LSC 7.3.1.2) Business: 100 gross sf/person Storage: NA
Second Floor Non-Resident: 1542 SF Business = 16 people
Sprinklers Present: Yes
Egress Capacity: (LSC 7.3.3) Stairs: 0.3" / person
Level components and ramps (Doors, etc..): 0.2"/per Maximum Travel Distance: (LSC 7.6.1)
Business: 300 ft Storage: NA
Maximum Dead End Limit: (LSC 7.6.1) Business: 50 ft Storage: NA
Maximum Common Path of Travel: (LSC 7.6.1) Business: 100 ft Storage: NA
Building Component Ratings:
Structural Frame: 0 hrs Bearing Walls: 0 hrs Nonbearing walls: 0 Floor Construction: 0 hrs Roof Construction: 0 hr
Rated Separations:
Shaft enclosure: 2 hr
Corridors: 2 hr Interior Finish Limitations:
Class A or B in all spaces, except Exits Class A in Exits
APPLICABLE CODES & STANDARDS
- INTERNATIONAL BUILDING CODE:
2018 EDITION
- NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
101 LIFE SAFETY CODE (LSC):
2018 EDITION
- INTERNATIONAL FUEL GAS CODE:
2018 EDITION
- INTERNATIONAL MECHANICAL CODE:
2018 EDITION
- INTERNATIONAL PLUMBING CODE:
2012 EDITION
- NATIONAL ELECTRICAL CODE (NEC):
2017 EDITION
- INTERNATIONAL FIRE CODE
2018 EDITION
- INTERNATIONAL ENERGY CONSERVATION CODE:
2015 EDITION
- FACILITIES STANDARDS FOR THE PUBLIC BUILDING
SERVICE- PBS-P100, 2018 EDITION.
- ARCHITECTURAL BARRIERS ACT ACCESSIBILITY
STANDARD (ABAAS), LATEST EDITION.
- US COURTS DESIGN GUIDE, LATEST EDITION.
1. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE CONTRACTOR’S BEST SKILL AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR, AND HAVE CONTROL OVER, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK. IF THE CONTRACT DOCUMENTS GIVE SPECIFIC INSTRUCTIONS CONCERNING CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, THE CONTRACTOR SHALL EVALUATE THE JOBSITE SAFETY THEREOF, AND SHALL BE FULLY RESPONSIBLE FOR THE JOBSITE SAFETY ASSOCIATED WITH SUCH INSTRUCTIONS. IF THE CONTRACTOR DETERMINES THAT SUCH INSTRUCTIONS MAY NOT BE SAFE, THE CONTRACTOR SHALL GIVE TIMELY WRITTEN NOTICE TO THE OWNER AND ARCHITECT AND SHALL NOT PROCEED WITH THAT
PORTION OF THE WORK WITHOUT FURTHER WRITTEN INSTRUCTIONS FROM THE ARCHITECT.
2. THE CONTRACTOR SHALL EMPLOY A COMPETENT SUPERINTENDENT AND NECESSARY ASSISTANTS WHO SHALL BE IN ATTENDANCE AT THE PROJECT SITE DURING PERFORMANCE OF THE WORK. THE SUPERINTENDENT SHALL REPRESENT THE CONTRACTOR AND COMMUNICATIONS GIVEN THE SUPERINTENDENT SHALL BE BINDING AS IF GIVEN TO THE CONTRACTOR.
3. DEMOLITION DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. CONTRACTOR SHALL CLEAN JOBSITE DAILY, MAINTAIN A CLEAN WORKPLACE AND KEEP CONSTRUCTION DEBRIS AND DUST AWAY FROM ADJACENT BUILDING OCCUPANTS.
4. INSTALL BLOCKING IN ALL WALLS INDICATED TO RECEIVE WALL MOUNTED DEVICES AND/ OR CABINETRY.
5. ALL WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED.
6. PROVIDE DOUBLE STUDS AT ALL OPENINGS IN WALLS.
7. NOT USED.
8. ALL VERTICAL RATED MECHANICAL CHASE ASSEMBLIES SHALL EXTEND FROM FLOOR FINISH TO STRUCTURE ABOVE.
10. ALL EXPOSED ELECTRICAL, FIRE PROTECTION, AND MECHANICAL DEVICES SHALL BE CENTERED ON OR ALIGN WITH
ARCHITECTURAL FEATURES AS SHOWN ON THE REFLECTED CEILING PLANS.
11. OPENINGS CREATED IN SLABS, SMOKE PARTITIONS, OR FIRE RATED PARTITIONS BY THIS WORK SHALL BE REPAIRED USING TECHNIQUES AND MATERIALS TO MAINTAIN THE RATING OF THE WALL, INCLUDING BUT NOT LIMITED TO SMOKE DAMPERS, FIRE DAMPERS, FIRESTOPPING, AND FIRE SAFING, PENETRATIONS OF MASONRY WALLS AND CONCRETE FLOORS SHALL BE STOPPED TO
MINIMUM 2 HOUR RATING.
12. CONTRACTOR IS TO COORDINATE WITH OWNER PROVIDED MATERIALS & SERVICES, INCLUDING: SECURITY EQUIPMENT AND
BREAKROOM APPLIANCES.
13. ALL DIMENSIONS ARE TO FACE OF FINISHED SURFACES, UNLESS NOTED OTHERWISE.
14. RELOCATE EXISTING FIRE SPRINKLER MAINS, BRANCHES, AND HEADS TO ACCOMODATE SPECIFIED CEILING HEIGHTS, CEILING CONFIGURATION, AND LIGHTING LAYOUT.
Keynote List:
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
05/06/19
09 91 23 INTERIOR PAINTING
10 28 00.PTD PAPER TOWEL DISPENSER
10 28 00.SD SOAP DISPENSER
10 28 00.TP TOILET PAPER DISPENSER
21 50 00 FIRE PROTECTION
21 50 00.SSH SS SPRINKLER HEAD
23 37 13.GRD GRILL, REGISTER OR DIFFUSER
23 80 00.D DUCTWORK
26 10 00 ELECTRICAL SERVICE AND
DISTRIBUTION
26 10 00.ED ELECTRICAL DEVICE
26 50 00.LF LIGHTING FIXTURE
06 20 00 FINISH CARPENTRY
06 20 00.CT CEILING TRIM
06 41 00.SS SOLID SURFACE COUNTERTOP
06 41 00.WVC WOOD VENEER CABINET
07 92 00 JOINT SEALERS
08 31 00.AP ACCESS PANEL
08 71 00.DH
08 71 00.SL SEAL
09 21 16 GYPSUM BOARD ASSEMBLIES
09 21 16.AI ACOUSTIC INSULATION
09 21 16.CL GYPSUM WALLBOARD-CEILING
09 21 16.GA GYPSUM BOARD ASSEMBLY
09 30 00 TILING
09 51 00 ACOUSTICAL CEILINGS
09 68 13 TILE CARPETING
09 72 00 WALL COVERINGS
Newly constructed elements and reconfigured systems shall comply with portions of the code applicable to new construction. The existing building undergoing renovation shall comply with the requirements of the existing portion of the business occupancy chapter. (LSC 43.4.3)
Life Safety Plan: Life Safety Notes: General Notes:
Legend:
Revision Number
TYPE "CW"
HISTORIC REFINISHED COPPER EXTERIOR WINDOW. STRIP EXISTING PAINT AND REFURBISH COPPER TO MATCH BUILDING STANDARD COPPER WINDOWS. CLEAR LACQUER FINISH OVER POLISHED COPPER.
REFINISH HISTORIC
WINDOW COPPER
EXISTING TRIM TO
REMAIN. PAINT PT-2
EXISTING DOOR
AND FRAME
08 71 00.SL
08 71 00.SL
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
MATERIAL KEYNOTES
GENERAL NOTES
SHEET SPECIFIC NOTES
C:\Users\HWA17\Documents\1855_Tuttle 233 _ R20_octavian@houserwalker.com.rvt
11/16/2020 3:33:09 PM
A020
11/18/20 100% Construction Documents
DOOR, WINDOW TYPES AND SCHEDULES
OT
GW
56 Forsyth Street Atlanta, Georgia
NXXXXXXX
Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Nonresident Chambers Renovations
Nonresident Chambers 233
Door Number Door Finish Frame Finish Hardware Set
207B 09 91 23.IP 09 91 23.IP HW-2
231A 09 91 23.IP 09 91 23.IP HW-2
232A 09 91 23.IP 09 91 23.IP Existing 232B 09 91 23.IP 09 91 23.IP Existing
232C 09 91 23.IP 09 91 23.IP HW-2
232D 09 91 23.IP 09 91 23.IP HW-2
232E Existing Transparent Finish Existing Transparent Finish HW-1
233A 09 91 23.IP 09 91 23.IP HW-2
233B 09 91 23.IP 09 91 23.IP HW-2
233C Existing Transparent Finish Existing Transparent Finish HW-1 233D Existing Transparent Finish Existing Transparent Finish HW-1
233E 09 91 23.IP 09 91 23.IP HW-2
Door Schedule:
A. SEE A100 FOR FINISH SCHEDULE
B. ALL DOORS ARE EXISTING TO REMAIN AND TO
BE REFINISHED AND RECEIVE NEW SEALS AS
SCHEDULED.
Copper Windows:
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
05/06/19
08 71 00.SL SEAL
09 91 23 INTERIOR PAINTING
Typical Door Seals:
Revision Number
Judge's Chambers
Vestibule 207B Toilet
231A
Law Clerk 233B
Library
Law Clerk 233A
A100P8
Law Clerk 233A
Law Clerk 233B
LIBRARY
Judges Chambers
Toilet 231A
Vestibule 207B
Electrical 232B
Closet 232A
A300
E4
A1
E1
F W
C B
D
CPT-1
PT, WC-1
ACT, GYP
EXISTING
DEV-1
F W
C B
D
CPT-1
PT, WC-1
ACT, GYP
EXISTING
DEV-1
F W
C B
D
CPT-1
PT, WC-1
GYP
EXISTING
DEV-1
F W
C B
D
CPT-1
PT, WC-1
GYP
EXISTING
DEV-1
F W
C B
D
CPT-1
PT,WC-1
GYP
EXISTING
DEV-1
CW
CW
CW CW
F W
C B
D
FT-1, FT-2
CT, WC-2
GYP
TB-1
DEV-1 A300
E7
NOTE 3
NOTE 3
NOTE 6
NOTE 6
NOTE 6 NOTE 6
A100P8
A100P8
233D
233A
233B 233C
2C
232E
7B
232D 231A
3E
2A
2B
A
LI
G N
N
O
TE
NOTE 7
NOTE 8
PT
-2
W C
-1
PT
-2
PT
-1
NOTE 5
2ND FL KEY PLAN
CALLED
NORTH
PRESUMED ASBESTOS CONTAINING
TILE UNDER EXISTING FINISH
UNKOWN UNDERLAYMENT
FILL PATTERN LEGEND
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
C:\Users\HWA17\Documents\1855_Tuttle 233 _Rev20_octavian@houserwalker.com.rvt
3/17/2021 7:12:56 PM
A100
11/18/20 100% Construction Documents
CHAMBER 233 - DEMO AND NEW
OT
GW
56 Forsyth Street Atlanta, Georgia
NXXXXXXX
Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Nonresident Chambers Renovations
Nonresident Chambers 233
06 20 00.CT CEILING TRIM
09 21 16 GYPSUM BOARD ASSEMBLIES
09 30 00 TILING
09 51 00 ACOUSTICAL CEILINGS
09 68 13 TILE CARPETING
09 72 00 WALL COVERINGS
09 91 23 INTERIOR PAINTING
26 10 00 ELECTRICAL SERVICE AND DISTRIBUTION
A100 3/16" = 1'-0"
A4 CH. 233 - FLOOR PLAN - DEMO
A100 3/16" = 1'-0"
H4 CH. 233 - FLOOR PLAN - NEW
FINISHES SCHEDULE:
TYPE MARK KEYNOTE DESCRIPTION PRODUCTDISTRIBUTOR / MANUF. COMMENTS
ACT ACOUSTICAL CEILING
CT-1 CERAMIC TILE
WC-2
CPT-1
CEILING
WALLS
FLOORING
FT-1
BASE
TB-1
WC-1 WALL COVERING
PT-3 PAINT
WALL COVERING
CERAMIC TILE BASE
CARPET
STONE TILE
CT-2 CERAMIC TILE
RENAISSANCE TILE & BATH GRANDVIEW FAIRMONT 4" X 1" FAIRMONT - PICKET - HONED SANDED GROUT COLOR 'FG-1' TO BE SELECTED BY
ARCHITECT FROM MERKRETE AND LATICRETE'S FULL
COLOR OFFERINGS. ONE FULL COURSE OF FT-2 BORDER AT
WALL. NOTE 8FT-2 STONE TILE RENAISSANCE TILE & BATH GRANDVIEW FAIRMONT 3" X 12" FAIRMONT - HONED
CT-3 CERAMIC TILE
PT-1 PAINT
PT-2 PAINT
DEVICES
COVERS AND DEVICESDEV
HEATH CLASSIC FIELD M3 PARCHMENT, 3" X 6"
ARMSTRONG ULTIMA WHITE, 24" X 24" X 3/4"
SHERWIN WILLIAMS CEILING BRIGHT WHITE, SW 7007, FLAT
FARROW & BALL ALL WHITE (TRIM), SEMIGLOSS
BENJAMIN MOORE OC-45, SWISS COFFEE, EGGSHELL
MELJAC CLASSIQUE
HEATH CIRCLE LINEAR TILE
HEATH STEP LINER
M3 PARCHMENT, 1" X 6"
M3 PARCHMENT, 6"
GROUT COLOR TO BE SELECTED BY ARCHITECT
1 COURSE, AS INDICATED
TOP COURSE, AS INDICATED
TARKETT ZONA II SAIL CLOTH, ROLL GLUED
FARROW & BALL DRAG WALLPAPER, DR 611, ROLL
MAHARAM LUCID, 399632-001 SIBERIA
HEATH COVE BASE TILE M3 PARCHMENT, 3" X 6" SET BOTTOM EDGE FLUSH TO FLOOR
09 51 00
09 91 23
09 91 23 09 91 23
09 30 00
09 30 00
09 30 00
09 72 00
09 72 00
09 68 13
BEVELED TEGULAR, NRC, 75
09 30 00
GWB GYPSUM CEILING09 21 16
MILLWORK
CTOP-1 SOLID SURFACE CORIAN
WVC-1
BRONZE MÉDAILLE, CLEAR, SCREWLESS
WOOD VENEER OPAQUE STAIN, COLOR TBD
STORM GREY LEATHERED, 2 CM THICKNESS06 41 00
06 41 00 WHITE OAK
ONE PUSH BUTTON, ORIENT TO EXISTING POSITION
CEILING PAINT
TRIM, DOOR, FRAME AND MILLWORK PAINT
TYPICAL PAINT
A100 1/2" = 1'-0"
P8 233 - TYPICAL WALL ELEVATION
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
05/06/19
1. LIMITED PRE-RENOVATION TESTING REVEALED ACM AND LEAD BASED / CONTAINING PAINT. INSPECT AND DETERMINE THE TOTAL QUANTITIES OF ACM AT ALL LOCATIONS WITHIN THE SCOPE, PRIOR TO DEMOLITION RELATED DISTURBANCE. ABATE ACM AND PREPARE LEAD BASED / CONTAINING PAINT FOR ENCAPSULATION. SPECIFICATION SECTIONS ‘02 4250 SELECTIVE DEMOLITION’ AND ’09 9020 ENCAPSULATION’. AT AREAS IDENTIFIED TO BE CONTAINING ACM FLOORING, CAREFULLY REMOVE EXISTING CARPET AND PADDING AND ABATE EXISTING TILE AND MASTIC, LEAVING EXISTING WOOD FLOOR IN PLACE. IF WOOD FLOORING IS DAMAGED, REPLACE WITH LIKE KIND AND PREP FOR NEW FLOOR FINISH. REMOVE WALL COVERING, ACT CEILING, LIGHTING, ALL ABANDONED PIPING AND ALL ABANDONED CONDUIT, AS THEY EXIST.
2. REMOVE EXISTING FIXTURES, SEE PLUMBING DRAWINGS. REMOVE FLOOR TILE, WALL TILE, TOILET ACCESSORIES, CEILINGS, LIGHTING AND TOILET PARTITIONS, AS NOTED.
3. PAINT BOOKCASES, PT-2
4. EXISTING BOOKCASE TO BE RELOCATED
5. EXISTING CHAIR RAIL, WHERE PRESENT. ADD NEW CHAIR RAIL TO MATCH, IN LAW CLERK 233A , 233B AND AT LIBRARY WALL EXPOSED BY THE RELOCATED BOOKCASE.
6. REFURBISH EXISTING COPPER WINDOWS TO MATCH BUILDING STANDARD.
7. RELOCATED BOOKCASE. ALIGN EDGE OF BOOKCASE WITH EDGE OF EXISTING DOOR FRAME. MODIFY CHAIR RAIL AS NEEDED TO MAINTAIN LIBRARY WIDTH THE SAME BEFORE AND AFTER RELOCATION.
8. INSTALL FLOOR TILE WALL TO WALL AND BELOW NEW FIXTURES AND CASEWORK
A. RELOCATE EXISTING FIRE SPRINKLER MAINS, BRANCHES, AND HEADS TO ACCOMODATE SPECIFIED CEILING HEIGHTS, CEILING CONFIGURATION, AND
LIGHTING LAYOUT.
B. CONTRACTOR TO SEAL, CAULK, AND IN-FILL ANY EXISTING AND NEW PENETRATIONS OR OPENINGS AT ALL WALLS LOCATED WITHIN THE SCOPE OF WORK AREA AS REQUIRED FOR A COMPLETELY ACOUSTICALLY SEALED CONDITION, BOTH SIDES, TYP.
C. CONTRACTOR IS RESPONSIBLE FOR REROUTING ANY EXISTING CONDUITS, WIRING, PLUMBING AND PIPING AS REQUIRED TO ACHIEVE THE DESIRED LAYOUT AND DESIGN INTENT SHOWN. NEW REROUTING LOCATIONS SHALL BE CONCEALED WITHIN WALL. WHEN IT IS IMPOSSIBLE TO CONCEAL ITEMS, LOCATE ITEMS TIGHT AGAINST WALLS- ENCLOSE ITEMS WITH GYPSUM WALL BOARD WITHOUT DISRUPTION OF SERVICE TO OTHER AREAS.
D. ALL ARCHITECTURAL WOODWORK, WINDOW TRIM, JAMBS AND SILLS TO REMAIN. PROTECT EXISTING WINDOWS AND DOORS TO REMAIN DURING
CONSTRUCTION.
E. SEE A020 DOOR SCHEDULE FOR DOORS AND FRAMES TO BE PAINTED.
09 30 00
09 30 00
26 10 00
MATERIAL KEYNOTES GENERAL NOTES SHEET SPECIFIC NOTES
Revision Number
Revision Date Revision Description
A. REMOVE AND ABATE ASBESTOS CONTAINING 9X9 TILE AND MASTIC, WHERE PRESENT, BELOW THE EXISTING CARPET AND PADDING. IT IS ESTIMATED THAT APPROXIMATELY 400 SQUARE FEET OF TILE ARE PRESENT BUT THE EXACT QUANTITY IS UNKNOWN. REPORT OF LIMITED PRE-RENOVATION ASBETOS CONTAINING MATERIAL AND LEAD BASED PAINT SAMPLING FOR TUTTLE BUILDING - SUITE 233 , NOVA PROJECT NO.3020073 09/01/20 IS AVAILABLE AS APPENDIX TO THESE CONTRACT DOCUMENTS.
B. HAZARDOUS MATERIAL SAMPLYING HAS IDENTIFIED LEAD BASED PAINT ON THE EXISTING PLASTER WALLS AND PLASTER CEILINGS. SCHEDULED REMOVAL OF WALLS SHOULD BE DONE IN ACCORDANCE WITH OSHA 1926.62 REGULATIONS GOVERNING LEAD-SAFE PRACTICES. LEAD BASED PAINT IN CEILINGS AND EXISTING TO REMAIN WALLS SHALL BE ABATED VIA ENCAPSULATING PAINT. THE CONTRACTOR SHALL PREPARE FOR ENCAPSULATION BY REMOVING LOOSE AND FLAKING PAINT BY WET
SCRAPING. REFER TO 09 9020.
C. FOR LBP ENCAPSULATION ABATEMENT, THE MEANS AND METHODS FOR WORKER PROTECTION AND MONITORING, ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
THE CONTRACTOR SHALL COMPLY WITH CURRENT OSHA 1926.62 LEAD REGULATIONS FOR LEAD SAFETY RELATED TO OCCUAPATIONAL HAZARDS.
D. ABATE ALL EXISTING PIPING WITHIN SCOPE OF WORK WRAPPED IN ASBESTOS CONTAINING MATERIALS, KNOWN AS THERMAL SYSTEM INSULATION (TSI).
ABATEMENT NOTES
TB-1
3/
4" 2"
1" 3'
1/ 8"C
T-
T
IL
E
C O
UR
SE
S
C T-
C
T-
C T-
C
O U
RS
E
C
O U
RS
E
C
O U
RS
E
, NOTE 107 92 00
N O
TE
O N
E
FU
LL
T
IL
E
HA
LF
T
IL
E
TB
-1
FT
-2
FT-1
FT
-1
J1
A300
ALIGN, NOTE 3
06 20 00
MIRROR
ALIGN,
NOTE 4
A4
A300
3' - 3"
06 41 00.WVC
WC-2,
TYP.
10 28 00.PTD
G1
A510
A1
A510
6" 2' - 8" 6"
OF MIRROR
AND CABINET
26 50 00.LF
TYP.
OF FIXTURE
OF FIXTURES
AND MIRROR
3'
1"
26 10 00.ED
OF FIXTURE
AND RECEPTACLE
OF
RECEPTACLE
RECEPTACLE
1' - 0 3/4"2'
CW
2ND FL KEY PLAN
CALLED
NORTH
PANEL MOULDING.
P&P PM-2149
3/4"
MIRROR SURFACE
ALIGN
1/
2"
WALL TILE,
BELOW
A300
E4
A1
E1
A300 J7
10 28 00.TP
OF WALL AND
MIRROR
ALIGN, NOTE 3
7'
0"
2' - 4"
A4
A300
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
MATERIAL KEYNOTES
GENERAL NOTES
SHEET SPECIFIC NOTES
C:\Users\HWA17\Documents\1855_Tuttle 233 _ R20_octavian@houserwalker.com.rvt
11/16/2020 3:33:18 PM
A300
11/18/20 100% Construction Documents
ENLARGED PLANS AND DETAILS
OT
GW
56 Forsyth Street Atlanta, Georgia
NXXXXXXX
Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Nonresident Chambers Renovations
Nonresident Chambers 233
06 20 00 FINISH CARPENTRY
06 41 00.WVC WOOD VENEER CABINET
07 92 00 JOINT SEALERS
10 28 00.PTD PAPER TOWEL DISPENSER
10 28 00.TP TOILET PAPER DISPENSER
26 10 00.ED ELECTRICAL DEVICE
26 50 00.LF LIGHTING FIXTURE
1. USE SEALANT INSTEAD OF GROUT WHERE TILE
BASE AND FLOOR TILE MEET. COLOR TO BE
SELECTED BY ARCHITECT
2. EXISTING TRANSITION TRIM TO REMAIN
3. ALIGN TOP OF MIRROR WITH TOP OF DOOR
FRAME
4. ALIGN BOTTOM OF MIRROR WITH TOP OF WALL
TILE
A300 12" = 1'-0"
J1 SECTION DETAIL AT WALL TILE
A300 3" = 1'-0"
J7 PLAN DETAIL AT FLOOR TILE
A300 1/2" = 1'-0"
E4 233 BATHROOM ELEVATION N
A300 1/2" = 1'-0"
E1 233 RESTROOM ELEVATION S
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
05/06/19
A300 3" = 1'-0"
A4 MIRROR FRAME DETAIL
A300 3/8" = 1'-0"
E7 CH. 233 - TOILET ENLARGED PLAN
A300 1/2" = 1'-0"
A1 233 RESTROOM ELEVATION W
A. SEE A100 FOR FINISH SCHEDULE
Revision Number
RECESSED
LIGHT FIXTURES
HVAC
SUPPLY
DIFFUSER
PENDANT
SPRINKLER
HEAD
ACCESS PANEL
SIDEWALL
SPRINKLER
HEAD
HVAC
RETURN
DIFFUSER
PENDANT
LIGHT FIXTURES
RECESSED TROFFER
LIGHT FIXTURES
EXIT SIGN
LIGHTING
ASSOCIATED
OCCUPANCY
SENSOR
Law Clerk 233A
Law Clerk 233B
LIBRARY
Judges Chambers
Toilet 231A
Vestibule 207B
Electrical 232B
Closet 232A
8' - 0"
8' - 0"
8' - 0"
9' - 7 1/2"
9' - 7 1/2"
8' - 0"
G6
A400
G2
A400
O F
FI
XT
U
RE
S A
N D
D O
O R
5'
1/
8" 5'
1/ 4"
1'
6" 1'
6"
EQ EQ
TY
P.
4'
0"
EQ EQ
EQ 'D' 2' - 6" 2' - 6" EQ 'D'
EQ
EQ
TY
P.
EQ
EQ
10" 10"
EQ
'A
EQ
'A
EQ
'B
EQ
'B
NOTE 2
G6
A400
SIM
G6
A400
SIM
NOTE 2
G6
A400
SIM
2'
0" 2'
0"
23 37 13.GRD
OF FIXTURES
, SPRINKLER HEADS
,DIFFUSER AND ROOM
OF FIXTURE
AND DOOR
OF FIXTURES
AND DOOR
EQ EQ
EQ EQ
NOTE 1
NOTE 4
9"
23 37 13.GRD
23 37 13.GRD
TYP.
NOTE 2
NOTE 7
G2
A400
SIM
10"
2' - 0" EQ 'C' 6' - 0" 6' - 0" EQ 'C' 2' - 0"
OF DIFFUSERS,
SPRINKLER
AND DEVICE
OF FIXTURES
AND EDGE OF
HIGH CEILING
OF FIXTURES OF FIXTURES,
SPRINKLER AND
DIFFUSERS
OF DIFFUSERS,
SPRINKLER
2' - 6" 2' - 6"
EQ EQ
OF FIXTURES
AND EDGE OF
HIGH CEILING
OF FIXTURES
2' - 0"
1' - 4"
OF FIXTURES
AND DEVICE
OF FIXTURES, SPRINKLERS
DEVICES AND DOOR
5'
4"
1'
3'
6" 8"
1'
4" 2'
2'
0"
OF FIXTURES AND DOOR
OF FIXTURES,
SPRINKLER
OF FIXTURES,
DEVICE
OF SPRINKLER
OF SPRINKLERS
N6
A400
EQ
EQ
1'
2"
10"
ALIGN W/
TOP OF
WINDOW
06 20 00.CT
1 1/4" BED MOULDING.
P&P PM-1186
09 51 00
IN JUDGES 09 21 16.CL
N6
A400
CHAMBERS 232
06 20 00.CT
IN JUDGES CHAMBERS 232
1 1/4" BED MOULDING.
P&P PM-1186
5" CROWN MOULDING.
P&P PM-1003,
06 20 00.CT
1/
4"
3 1/2"
09 21 16.GA
09 21 16.AI
8' - 0"
LOW CEILING
10' - 1"
UNDERSIDE OF DECK.
FIELD VERIFY
EXISTING BEAM, WHERE
PRESENT. FIELD VERIFY
HIGH CEILING
EQ
EQ
OF DIFFUSER AND
SIDWALL SPRINKLER AT
SIM
8' - 1 1/2"
UNDERSIDE OF EXISTING
WATER PIPING. FIELD VERIFY
23 80 00.D
AT SIM.
NOTE 5
EXISTING WATER PIPING
AT SIM
21 50 00
AT SIM
9' - 9"
9' - 6 7/8"
SIDWALL SPRINKLER AT
SIM
21 50 00.SSH
06 20 00.CT
A
LI
G N
N O
TE
EXISTING DOOR FRAME, BEYOND,
06 20 00.CT
2ND FL KEY PLAN
CALLED
NORTH
06 20 00.CT
06 20 00.CT
1 1/4" BED MOULDING.
P&P PM-1186
ALIGN. NOTE 6
EXISTING DOOR FRAME,
WHERE PRESENT
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES
C:\Users\HWA17\Documents\1855_Tuttle 233 _ R20_octavian@houserwalker.com.rvt
11/16/2020 3:33:20 PM
A400
11/18/20 100% Construction Documents
CHAMBER 233 CEILING PLAN
OT
GW
56 Forsyth Street Atlanta, Georgia
NXXXXXXX
Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Nonresident Chambers Renovations
Nonresident Chambers 233
06 20 00.CT CEILING TRIM
09 21 16.AI ACOUSTIC INSULATION
09 21 16.CL GYPSUM WALLBOARD-CEILING
09 21 16.GA GYPSUM BOARD ASSEMBLY
09 51 00 ACOUSTICAL CEILINGS
21 50 00 FIRE PROTECTION
21 50 00.SSH SS SPRINKLER HEAD
23 37 13.GRD GRILL, REGISTER OR DIFFUSER
23 80 00.D DUCTWORK
A. ALL DIMENSIONS ARE TO FACE OF FINISHED SURFACES, UNLESS OTHERWISE NOTED.
B. SURFACES INDICATED TO BE ALIGNED ARE TO HAVE FINISH SURFACES FLUSH WITH ONE ANOTHER.
C. COORDINATE ALIGNMENT OF FIRE SPRINKLERS WITH RECESSED LIGHT FIXTURES, AS INDICATED.
D. IT IS THE INTENT OF THE CEILING DESIGN TO MAXIMIZE CEILING HEIGHTS. MEPFP COMPONENTS SHALL BE INSTALLED
AS HIGH AS POSSIBLE TO ACHIEVE DESIGN INTENT. IF NOTED CEILING HEIGHTS CAN BE RAISED, COORDINATE WITH
ARCHITECT OR OWNER REPRESENTATIVE.
E. ALL RENOVATED SPACES ARE TO RECEIVE CROWN MOLDING. SEE A1/A510 FOR TYPICAL DETAIL.
CEILING LEGEND
1. CENTER ELEMENT OR DEVICE IN CEILING TILE. TYP.
2. PROVIDE FULL WIDTH WINDOW COVE, TYP.
3. MITER AND RETURN CROWN MOLDING TO WALL AT CORNER.
4. CENTER 24"X24" CEILING ACCESS PANEL IMMEDIATELY UNDERNEATH THE RETURN AIR CHASE OPENING TO FLOOR ABOVE.
5. MOUNT HVAC DUCTWORK TIGHT TO UNDERSIDE OF EXISTING BEAMS
6. SIZE TRIM SUCH THAT ITS BOTTOM ALIGNS WITH TOP OF DOOR FRAMES 233A, 233B, 233C. FACE OF TRIM TO ALIGN WITH FACE OF DOOR FRAMES.
7. ALIGN ENDS OF WINDOW COVE TO OUTSIDE OF WINDOW TRIM
A400 3/16" = 1'-0"
A3 CH.233 - RCP
A400 3" = 1'-0"
G6 TYP. CEILING DETAIL AT WINDOW
A400 3" = 1'-0"
G2 TYP. HIGH CEILING DETAIL
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
05/06/19
Revision Number
Revision Date Revision Description
A400 3" = 1'-0"
N6 TYP. LOW CEILING TRIM
2'
CTOP-1.
EASED EDGES
1/
8" 4"
1" 2'
0"
FACE
FRAME
INSET A.D.A.
DOOR
W 1/8"
RECESSED
PANEL, TYP.
AND
INTEGRAL TOE
KICK
3"
1/2"
2"
2' - 0"
2'
CTOP-1.
EASED EDGES
0"
TY
P.1"
FACE
FRAME
INSET DOOR
W 1/8"
RECESSED
PANEL, TYP.
3"
1/
8" 2'
3"
06 41 00.WVC
06 41 00.SS
10 28 00.PTD
A510 A5
TY
P
1/
4"
NOTE 1
EQ
EQ
1/8"
06 41 00.WVC
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
MATERIAL KEYNOTES
GENERAL NOTES
SHEET SPECIFIC NOTES
C:\Users\HWA17\Documents\1855_Tuttle 233 _ R20_octavian@houserwalker.com.rvt
11/16/2020 3:33:22 PM
A510
11/18/20 100% Construction Documents
MILLWORK DETAILS
OT
Approver
56 Forsyth Street Atlanta, Georgia
NXXXXXXX
Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Nonresident Chambers Renovations
Nonresident Chambers 233
06 41 00.SS SOLID SURFACE COUNTERTOP
06 41 00.WVC WOOD VENEER CABINET
10 28 00.PTD PAPER TOWEL DISPENSER
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
05/06/19
A. COORDINATE CASEWORK HARDWARE WITH
SECTION 06 4100 OF THE PROJECT MANUAL.
A510 1 1/2" = 1'-0"
A1 SINK BASE 1
A510 1 1/2" = 1'-0"
G1 TWO DRAWERS WITH TOWEL DISPENSER
A510 12" = 1'-0"
A5 TYP. DRAWER EDGE DETAIL
Revision Number
Revision Date Revision Description
1. OMMIT FACE FRAME AT BOTTOM TO
MATCH ADA DOORS
A1001
Law Clerk 233A
Law Clerk 233B
LIBRARY
Judges Chambers
Toilet 207A
Toilet 231A
Vestibule 207B
Vestibule 207C
Vestibule 207D
Electrical 232B
Closet 232A
A300
E4
A1
E1
2ND FL KEY PLAN
CALLED
NORTH
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES
C:\Users\HWA17\Documents\1855_Tuttle 233 _ R20_octavian@houserwalker.com.rvt
11/16/2020 3:41:01 PM
AI100
11/18/20 100% Construction Documents
CHAMBER 233 - RCP + FURNITURE
COORDINATION
OT
Approver
56 Forsyth Street Atlanta, Georgia
NXXXXXXX
Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Nonresident Chambers Renovations
Nonresident Chambers 233
AI100 3/16" = 1'-0"
A2
CH. 233 - RCP AND FURNITURE
COORDINATION
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
05/06/19
Revision Number
C
T
HVAC LEGEND & ABBREVIATIONS
SYMBOL DESCRIPTION
RECTANGULAR AIR DUCT - FIRST DIMENSION IS SIDE SHOWN00x00
DUCT TRANSITION, RECTANGULAR TO ROUND OR OVAL
ROUND DUCT (A"∅) OR FLAT OVAL
FIRE DAMPER
AIR DUCT FLEXIBLE CONNECTOR
SUPPLY OR OUTSIDE AIR RECTANGULAR DUCT RISE OR DROP
RETURN AIR RECTANGULAR DUCT RISE OR DROPOR
OR
45° BRANCH TAKE-OFF WITH SPLITTER DAMPER AND CONTROL ROD
SINGLE BLADE DAMPER
M.D.
SMOKE DAMPER
COMBINATION FIRE/SMOKE DAMPER
SQUARE ELBOW WITH TURNING VANES
DUCT TRANSITION, RECTANGULAR TO RECTANGULAR
RADIUS ELBOW TAKE-OFF
FLEX DUCT AT DIFFUSER
DUCT-MOUNTED STATIC PRESSURE SENSOR
MANUAL VOLUME DAMPER
MD
OR
CONCENTRIC REDUCER
LINED DUCTWORK, DIMENSIONS ARE OUTER METAL TO OUTER METAL
SMOKE DETECTOR
SDT
PIPE FLOW ARROW
GRADE ARROW-INDICATES RISE OR DROP IN DUCT OR PIPEUP DNOR
CONDENSATE DRAINC
ABOVE FINISHED FLOORAFF
BOTTOM OF STRUCTUREBOS
MOTOR OPERATED DAMPERMOD
TEMPERATURE SENSOR
BACKDRAFT DAMPER
OR EXHAUST AIR RECTANGULAR DUCT RISE OR DROP
CARBON DIOXIDE SENSOR
ECCENTRIC REDUCER FLAT SIDE ON
BOTTOM OR FLAT SIDE ON TOP
MOTOR OPERATED DAMPER SAME SIZE AS
DUCT UNLESS OTHERWISE NOTED
www.houserwalker.com
A B C D E F G H J K M N P R
Nonresident Chambers Renovations
Nonresident Chambers 233
BRANDY M. NABORS
ELBERT P. TUTTLE COURT OF APPEALS BLDG
56 FORSYTH STREET NW
ATLANTA GA
GA 00088ZZ
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
SHEET OF
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
NXXXXXXX
11/16/2020 5:34:09 PM
MP001
11/18/20 100% Construction Documents
HVAC & PLUMBING LEGEND AND
ABBREVIATIONS
GBP
TLN
1 EXISTING EQUIPMENT AND PIPING TO REMAIN, UNLESS NOTED TO BE REMOVED.
2 VERIFY LOCATIONS OF EXISTING PIPING AND EQUIPMENT PRIOR TO BEGINNING WORK.
5 PROVIDE INSULATED FLEXIBLE DUCT TO DIFFUSER SAME SIZE AS DIFFUSER NECK SIZE WITH SPIN-IN, SCOOP AND SINGLE
BLADE DAMPER AT DIFFUSER TAKE-OFF.
7 RUNOUTS TO DIFFUSERS SHALL BE SAME SIZE AS DIFFUSER NECK, UNLESS OTHERWISE NOTED.
8 ROUTE DUCTWORK AS TIGHT TO STRUCTURE AS POSSIBLE, UNLESS OTHERWISE NOTED,
9 MAXIMUM FLEXIBLE DUCT RUNOUT TO BE SEVEN FEET. USE GALVANIZED STEEL DUCT FOR INDIVIDUAL RUNOUTS OVER
SEVEN FEET.
10 BALANCE AIR DISTRIBUTION SYSTEMS AS NOTED.
11 UNLESS OTHERWISE NOTED, WALL MOUNTED THERMOSTATS AND SENSORS SHALL BE MOUNTED AT 4'-0" AFF.
12 COORDINATE ALL LAY-IN CEILING DIFFUSERS WITH ARCHITECTURAL REFLECTED CEILING PLAN.
13 PROTECT ALL MATERIALS AND EQUIPMENT FROM DAMAGE.
14 CONTRACTOR SHALL PAINT ALL DUCTWORK VISIBLE THROUGH SUPPLY AND RETURN AIR OPENINGS AND GRILLES FLAT
BLACK.
15 ALL RETURN AIR GRILLES TO BE R-1 TYPE UNLESS OTHERWISE NOTED.
16 ALL SUPPLY AIR DIFFUSERS SHALL BE TYPE S-1 UNLESS OTHERWISE NOTED.
17 ALL FLEX DUCT TO BE MECHANICALLY ATTACHED. CLAMP ONLY IS NOT SUFFICIENT. CONTRACTOR TO HAVE METHOD
APPROVED BY ENGINEER PRIOR TO INSTALLATION.
18 DUCT SIZES SHOWN ON DRAWINGS PROVIDE THE MINIMUM CROSS-SECTIONAL AREA REQUIRED. INCREASE OVERALL
DUCT DIMENSIONS AS NECESSARY TO ACCOMMODATE DUCT LINER THICKNESS.
HVAC GENERAL NOTES (APPLICABLE TO ALL HVAC SHEETS)
PLUMBING GENERAL NOTES (APPLICABLE TO ALL HVAC SHEETS)
1. DRAWINGS ARE DIAGRAMMATIC ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR BUILDING DIMENSIONS AND EXACT
LOCATIONS AND ELEVATIONS OF ALL FIXTURES AND EQUIPMENT.
2. VERIFY EXACT LOCATIONS AND REQUIREMENTS OF FIXTURES AND EQUIPMENT PRIOR TO PROCEEDING WITH THE WORK.
3. COORDINATE PIPING WITH DUCTWORK, LIGHTING FIXTURES, STRUCTURE, AND ARCHITECTURAL CEILING HEIGHTS.
4. WHERE STRUCTURE IS DAMAGED DURING CONSTRUCTION AND INSTALLATION OF EQUIPMENT OR FIXTURES, THE
CONTRACTOR SHALL REPAIR THE DAMAGED AREA TO MATCH THE PROPOSED CONDITION.
5. PENETRATIONS OF RATED ASSEMBLIES SHALL BE FIRE STOPPED AS SPECIFIED.
6. MAKE FINAL CONNECTIONS TO ALL FIXTURES AND EQUIPMENT, INCLUDING EQUIPMENT PROVIDED UNDER OTHER
DIVISIONS.
7. ALL PIPING DROPS IN WALLS AND CHASES SHALL BE SECURED TO THE WALLS.
8. CAP ALL PIPING ENDS DURING CONSTRUCTION TO PREVENT ENTRY OF DEBRIS.
9. PROVIDE AND INSTALL NEW TEES, WYES, OR ELLS AT EACH WATER AND SEWER POINT OF CONNECTION.
10. VERIFY EXACT LOCATIONS AND REQUIREMENTS OF FIXTURES AND EQUIPMENT PRIOR TO PROCEEDING WITH THE WORK.
11. PIPING AND SYSTEMS NOT SHOWN TO BE REMOVED SHALL REMAIN.
12. REMOVE EXISTING FIXTURES SHOWN AND DISPOSE.
13. CONCEAL ALL PIPING IN FINISHED PORTIONS OF THE BUILDING UNLESS NOTED OTHERWISE.
14. CONNECTIONS BETWEEN TWO DISSIMILAR METALS SHALL BE MADE WITH DIELECTRIC UNIONS.
15. NEW WASTE SYSTEM SHALL BE RODDED-OUT AND FLUSHED CLEAN PRIOR TO FINAL INSPECTION OR TURNING THE
BUILDING OVER TO THE OWNER.
16. FLUSH, CLEAN, AND DISINFECT THE ENTIRE DOMESTIC WATER PIPING SYSTEM AS SPECIFIED.
17. WHERE PIPING VISIBLY PENETRATES THE WALLS, INSTALL ESCUTCHEONS TO COVER SLEEVES AND/OR CAULKING
THROUGHOUT FINISHED AREAS.
18. ALL FIXTURES AND EQUIPMENT SHALL BE KEPT CLEAN DURING ALL CONSTRUCTION AND NOT USED DURING
CONSTRUCTION.
19. HOT AND COLD WATER PIPING SYSTEM SHALL BE INSULATED THROUGHOUT THE PROJECT.
20 ALL FIXTURE CONNECTIONS SHALL BE MADE WITH NEW FITTINGS.
EX. 10"ø UP
VAV-2-8
EXISTING RA OPENING
IN SLAB WITH FD.
Judges Chambers
Toilet
207A
Toilet
231A
Vestibule
207C
Vestibule
207D
Vestibule
207B
Law Clerk
233B
LIBRARY
Law Clerk
233A
EXISTING HWS&R, CHWS&R
PIPING TO REMAIN.
T www.houserwalker.com
A B C D E F G H J K M N P R
Nonresident Chambers Renovations
Nonresident Chambers 233
BRANDY M. NABORS
ELBERT P. TUTTLE COURT OF APPEALS BLDG
56 FORSYTH STREET NW
ATLANTA GA
GA 00088ZZ
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
SHEET OF
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
NXXXXXXX
11/16/2020 5:34:09 PM
MP100
11/18/20 100% Construction Documents
HVAC & PLUMBING DEMO PLAN
GBP
TLN
GENERAL NOTES KEY NOTES
EXISTING VARIABLE AIR VOLUME UNIT AND ASSOCIATED TEMPERATURE SENSOR TO BE
RELOCATED AS SHOWN ON SHEET M200. REMOVE ASSOCIATED DUCTWORK AND AIR TERMINALS.
EXISTING TRANSFER AIR OPENING TO BE REPLACED WITH A TRANSER AIR BOOT.
EXISTING RECIRCULATION FAN TO BE REPLACED WITH NEW.
EXISTING RECIRCULATION FAN TO REMAIN.
11. SEE SHEET M001 FOR HVAC GENERAL NOTES
0 2 4 8 FT
SCALE: 3/16" = 1'-0"MP100
1 Level 2 - HVAC Demolition Partial Plan - Chambers Suite 233
EX. 10"ø UP
8"ø S-2
8"ø S-2
EXISTING RA OPENING
IN SLAB WITH FD.
x1
6"ø 12x12 S-3
Judges Chambers
Toilet
207A
Toilet
231A
Vestibule
207C
Vestibule
207D
Vestibule
207B
Law Clerk
233B
LIBRARY
Law Clerk
233A
DN
6" ø
8"ø12x10
10x6
36x3 S-1
8x6
36x3 S-1 x3 x3
VAV-2-25
VAV-2-8
x1 x1
36x3 S-1
EXISTING HWS&R, CHWS&R
PIPING TO REMAIN.
24x24 R-2
24x24 R-2
36x3R R-1
TYP.4
T
T
WC1L1
6 TYP.
EXIST.
36x3 S-1
20x6
TEF-2-5
10"ø www.houserwalker.com
A B C D E F G H J K M N P R
Nonresident Chambers Renovations
Nonresident Chambers 233
BRANDY M. NABORS
ELBERT P. TUTTLE COURT OF APPEALS BLDG
56 FORSYTH STREET NW
ATLANTA GA
GA 00088ZZ
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
SHEET OF
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
NXXXXXXX
11/16/2020 5:34:10 PM
MP200
11/18/20 100% Construction Documents
HVAC & PLUMBING NEW WORK PLAN
GBP
TLN
GENERAL NOTES KEY NOTES
EXISTING VARIABLE AIR VOLUME UNIT AND ASSOCIATED TEMPERATURE SENSOR TO BE RELOCATED
AS SHOWN.
NEW LINED RETURN AIR TRANSFER AIR DUCT. REFER TO 4/MP400 FOR DETAILS.
NEW VARIABLE VOLUME WITH ELECTRIC RE-HEAT. SEE SCHEDULES AND DETAILS FOR MORE
INFORMATION.
PROVIDE 24"x24" ACCESS PANEL IN HARD CEILING TO PROVIDE ACCESS TO VAV CONTROL PANEL, ELECTRIC DUCT HEATER OR FIRE DAMPER.
PROVIDE NEW CEILING RECIRCULATION FAN WITH FILTER.
LINEAR SLOT DIFFUSERS TO BE INSTALLED ON VERTICAL FACE OF SOFFIT. SEE ARCHITECTURAL RCP
PLAN FOR SOFFIT OUTLINE.
REPLACE EXISTING PLUMBING FIXTURE. EXISTING WASTE, VENT AND WATER PIPING SHALL REMAIN
AND BE REUSED BY NEW FIXTURE.
EXISTING PLUMBING FIXTURES TO REMAIN.
CONTRACTOR TO FIELD VERIFY IF WALLS GO UP TO STRUCTURE. IF WALL IS NOT PRESENT ABOVE
CEILING, TRANSFER AIR DUCT IS NOT NEEDED.
11. SEE SHEET M001 FOR HVAC GENERAL NOTES
3. ALL FLEX DUCT TO BE MECHANICALLY ATTACHED. CLAMP ONLY IS NOT
SUFFICIENT. CONTRACTOR TO HAVE METHOD APPROVED BY ENGINEER PRIOR
TO INSTALLATION.
0 2 4 8 FT
SCALE: 3/16" = 1'-0"MP200
1 Level 2 - HVAC & Plumbing New Work Partial Plan - Chambers Suite 233
FL
OWAI
R
TYPICAL CONICAL SPIN IN FITTING WITH
DAMPER
AND STAND-OFF BRACKET.
TYPICAL FLEXIBLE
DUCTWORK (MAXIMUM
LENGTH 7 FEET.)
TYPICAL
CEILING
DIFFUSER
BRANCH DUCT
FLOW
AIR
STRAIGHT
MIN.
2'-0"HANG UNIT WITH RUBBER IN SHEAR
ISOLATORS AND THREADED RODS.
FLEX CONNECTOR.
ELECTRIC REHEAT COIL.
USE FOR ALL DUCT 90° TAPS AT MEDIUM PRESSURE RECTANGULAR DUCT.
AI
R
FL
OW
45°
*W
DD
RE
CT
AN
GU
LA
R
MA
IN
D
UC
T
1" FLANGE ALL SIDES AND ATTACH WITH #10
SHEET METAL SCREWS 4" O.C. AND DUCT
SEALER ALL SIDES *W=1/4D (MIN 6")
HEIGHT (H) = DIAMETER (D)
ROUND
BRANCH
USE FOR ALL DUCT 45° TAPS AT MEDIUM PRESSURE RECTANGULAR DUCT.
1.7 5 X
D
AIR
FLO
W
2 x D
D
ROUND
BRANCH
45°
HEIGHT (H) = DIAMETER (D)
1" FLANGE ALL SIDES AND
ATTACH WITH #10 SHEET
METAL SCREWS 4" O.C. ALL SIDES AND DUCT
SEALER
RECTANGULA
R MAIN DUCT
OPEN END
CEILING
DUCT ABOVE
MINIMUM LENGTH IS
1.5 x DUCT WIDTH
TRANSFER DUCT, SIZE
LINED RETURN AIR
(LINER TO LINER) AS
NOTED ON DWG.
INTERIOR WALL
DUCT WIDTH
OPEN END
ADJACENT CEILING
DUCT ABOVE
www.houserwalker.com
A B C D E F G H J K M N P R
Nonresident Chambers Renovations
Nonresident Chambers 233
BRANDY M. NABORS
ELBERT P. TUTTLE COURT OF APPEALS BLDG
56 FORSYTH STREET NW
ATLANTA GA
GA 00088ZZ
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
SHEET OF
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
NXXXXXXX
11/16/2020 5:34:11 PM
MP400
11/18/20 100% Construction Documents
HVAC DETAILS
GBP
TLN
SCALE: NO SCALEMP400
3 FLEXIBLE DUCT TAKE-OFF DETAIL
SCALE: NO SCALEMP400
VARIABLE VOLUME TERMINAL UNIT
WITH ELECTRIC RE-HEAT
SCALE: NO SCALEMP400
90° ROUND/RECTANGULAR
DUCT TAP (PLAN VIEW)
SCALE: NO SCALEMP400
45° ROUND/RECTANGULAR
DUCT TAP (PLAN VIEW) SCALE: NO SCALEMP400
7 TRANSFER AIR "U" DUCT DETAIL
VAV/PIU TERMINALS POINTS LIST
VARIABLE VOLUME TERMINAL UNIT SCHEMATIC
HEATING/COOLING AUTOCHANGEOVER SEQUENCE
AIR TEMP
SUPPLY
PRIMARY AIR VALVE
CEILING
CEILING DIFFUSER
C
H
ZN- TEMP
AIR
RETURN
CEILING RETURN GRILLE
ELECTRIC REHEAT
COIL
MAX. HEATING SUPPLY TEMP.
(+15°F ABOVE SETPOINT)
AIRFLOW
SUPPLY
TEMPERATURE
HEATING
SETPOINT
COOLING
SETPOINT
HEATING MAXIMUM
AIRFLOW (APPROX. 50%
OF COOLING MAXIMUM)
DEADBAND
COOLING SUPPLY TEMP.
(APPROX. 55°F)
COOLING MAXIMUM
AIRFLOW
1ST
STAGE
HEATING
2ND
STAGE
HEATING
SUPPLY
AIR
85°F
NOTES
INPUTS
DIGITAL ANALOG
HU
MI
DI
TY
PO
W
ER
(A
MP
S/
KW
/K
W H)
MO
TO
R
CU
RR
EN
T
CO
2 L
EV
EL
(P
PM
ST
AT
IC
P
RE
SS
UR
E
AI
RF
LO
W
(C
FM
ON
/O
FF
OP
EN
/C
LO
SE
C
ON
TA
CT
AL
AR
M
CO
NT
AC
T
TE
MP
ER
AT
UR
E
SOFTWARE
ANALOG
OUTPUTS
DIGITAL
DD
C
MO
DU
LA
TI
ON
DI
FF
. P
RE
SS
. S
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .