This solicitation is for general construction services for the renovation of resident and non-resident judges' chambers at the Elbert P. Tuttle Federal Building in Atlanta, Georgia. The General Services Administration intends to award a firm-fixed-price contract between $1 million and $5 million through a competitive negotiation process using the Lowest Price Technically Acceptable selection procedure. The work includes renovations to two resident judge chambers and four non-resident judge chambers to accommodate the Court of Appeals. The contract is set aside for small businesses. Offerors must submit technical and price proposals, which will be evaluated separately. At the conclusion of the solicitation phase, GSA intends to award a single contract to one offeror for all construction services.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
KEY PLAN
CALLED
NORTH
Room name
1i
1t
A101
SIM
ROOM INDICATOR
SLOPE INDICATOR
DETAIL INDICATOR
KP
CR
SECURITY KEYPAD
SECURITY CAMERA
CARD READER ACCESS
TO BE REMOVED (DEMO SHEETS)
EXISTING TO REMAIN
NEW
HIDDEN FEATURES LINE
CENTER LINE
2 HOUR RATED WALL
1 HOUR RATED WALL
PATH OF EGRESS
EGRESS DOOR
# OF ROOM OCCUPANTS
ROOM OCCUPANCY TYPE
A #OCC.
EXIT EXIT SIGN
NORTH INDICATOR
BUILDING SECTION INDICATOR
WALL SECTION INDICATOR
BREAK LINE INDICATOR
WALL TYPE TAG INDICATOR
WINDOW TYPE TAG INDICATOR
2 41 8
GRAPHIC SCALE, 1/8" = 1'-0"
DOOR TAG INDICATOR
ELEVATION INDICATOR
CENTER LINE
M
06 41 00.PL KEYNOTE INDICATOR
(SEE PROJECT MANUAL)
0 GRID LINE
A101
SIM
INTERIOR ELEVATION INDICATOR
A101 EXTERIOR ELEVATION INDICATOR
CALLOUT INDICATOR
DRAWING TITLE
DIMENSION LINE
FIRE/HORN STROBE
MOTION DETECTOR
1 View Name A101 1/8" = 1'-0"
A101
SIM
A101
SIM
A101
1 Ref
Re f
Re f
1 Ref
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
CIVIL ENGINEER:
MEP ENGINEER:STRUCTURAL ENGINEER:
ARCHITECT:
Occupancy Type:
Construction Type:
Fire Suppression:
Project Name:Image: Project Information:
Project Team:
Drawing List:
C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt
3/18/2021 1:16:31 AM
G001
01/29/21 Consolidated Set
Cover Sheet gb
GW
Johnson Spellman & Assoc.
350 Research Court Suite 130 Peachtree Corners, GA 30092 678.336.5427
Westside Engineering 5525 Interstate North Parkway- Suite 200 Atlanta, GA 30328 404.965.1287
Houser Walker Architecture 1819 Peachtree Rd NE Suite 102 Atlanta, GA 30309 404.633.4264
Resident Judges Chambers on 2 Elbert P. Tuttle Court of Appeals 56 Forsyth St. NW Atlanta, GA
Existing, Business
Existing 1B (IBC) ; Type II (LSC)
Existing, Sprinklered
GS-04-P-15-BV-D-7018
GS-04P-13-BV-D-0009/47PE0218F0142
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1696691 Brandy Nabors
Resident Judge’s Chambers on 2
Interior renovation of Court of Appeals Judge's Chambers on second floor
Number Sheet Name 01 /2
9/
C on so lid at et
S et
C ur re nt
R ev isi on
G GENERAL
G001 Cover Sheet O G002 General Notes, Life Safety & Keynote List O
AD ARCHITECTURAL DEMOLITION
AD100 Second Floor Demolition Plan O
A ARCHITECTURAL
A020 Partition, Door, Window Types and Schedules O A100 Second Floor New Plan O A300 Enlarged Bathroom Plans / Elevations O A400 Second Floor Ceiling Plan O A500 Ceiling Details O A501 Details O A510 Millwork Details O A511 Millwork Details O A512 Millwork Details O A700 Library Elevations O A701 Judge Elevations O A702 Workroom/Breakroom Elevations O A703 Interior Elevations O A704 Interior Elevations O
AI ARCHITECTURAL INTERIORS
AI001 Second Floor Finish Schedule and Plan O AI002 Second Floor Interiors Details O AI003 Second Floor Furniture Reference Plan O
M MECHANICAL
M001 HVAC Legends and Abbreviations O M100 Second Floor HVAC Demolition Plan O M200 Second Floor HVAC New Work Plan O M400 HVAC Details O M500 HVAC Schedules, Control Sequences and I/O Summary O
ED ELECTRICAL DEMOLITION
ED200 Second Floor Demolition Plan O
E ELECTRICAL
E001 Notes Details Legend O E002 Lighting Schedule and Control Panel Riser O E100 Riser Diagram O E101 Panel Schedules O E200 Second Floor - Lighting Plan O E300 Second Floor - Power and Communications Plan O E400 Second Floor - Systems Plan O
P PLUMBING
P000 Plumbing Legend, Schedules and Notes O P200 Second Floor Plumbing Plans O
FP FIRE PROTECTION
FP200 Second Floor Fire Protection Plans O
Key: O = Current Issued NOT for Construction P = Previously Issued = Not Issued (blank) i = For Information Only
MPFP ENGINEER:ELECTRICAL ENGINEER :
Legend:
Revision Number
Revision Date Revision Description
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
03/26/19
F.E.C.
Judge
Judicial Assistant
Breakroom
Workroom
Law Clerk
Law Clerk
Law Clerk
Staff Attorney
Law Clerk
Mechanical
Judge Toilet
Toilet
Library
Intern
Stair
AREA NOT IN
SCOPE
200c
EX
IT
FIRE
EXTINGUISHER
CABINET
CALLED
NORTH
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt
3/18/2021 1:16:33 AM
G002
01/29/21 Consolidated Set
General Notes, Life Safety & Keynote List
GB
GW
GS-04-P-15-BV-D-7018
GS-04P-13-BV-D-0009/47PE0218F0142
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1696691 Brandy Nabors
Resident Judge’s Chambers on 2
Interior renovation of Court of Appeals Judge's Chambers on second floor
1. The Contractor shall maintain at the site for the Owner one copy of the Drawings, Specifications, Addenda, Change Orders and other Modifications, in good order and marked currently to indicate field changes and selections made during construction, and one copy of approved Shop Drawings, Product Data, Samples, and similar required submittals.
2. The Contractor shall perform work in accordance with the Contract Documents.
3. The drawings and specifications are complimentary and are to be understood comprehensively. Organization and arrangement of the drawings and/ or specifications into divisions, sections and articles shall not control the Contractor in dividing the work among subcontractors or in establishing the extent of Work to be performed by any trade.
4. Because the Contract Documents are complementary, the Contractor shall, before starting each portion of the Work, carefully study and compare the various Contract Documents relative to that portion of the Work, shall take field measurements of any existing conditions related to that portion of the Work, and shall observe any condition at the site affecting it. These obligations are for the purpose of facilitating coordination and construction by the Contractor and are not for the purpose of discovering errors, omissions, or inconsistencies in the Contract Documents. However, the Contractor shall promptly report to the Architect any errors, inconsistencies or omissions discovered by or made known to the Contractor as request for information.
5. Drawings are not to be scaled for information.
Contract Documents Existing Conditions
1. Existing adjacent portions of the building are to remain operational throughout construction. Coordinate construction activities and phasing with Architect, GSA COR, and Tenant Representative to minimize disruptions to owner’s operations and access, and to ensure safety of occupants.
2. Attention is called to the fact that this project is a renovation of an existing building.
Renovation of existing buildings require thorough coordination of the contract documents with the existing conditions. The Contractor must verify all relevant existing conditions, dimensions, and details prior to beginning construction.
3. All drawings and details incorporating existing conditions are representations of existing conditions only. The Contractor shall verify the accuracy of actual conditions and coordinate with the Architect any deviations of the details so to execute the intent of the drawing or detail.
4. Field Verify existing dimensions prior to ordering or cutting materials.
5. Cutting and Patching: The Contractor shall be responsible for cutting, fitting or patching required to complete the Work or to make parts fit together properly. All areas requiring cutting, fitting and patching shall be restored to the condition existing prior to cutting, fitting and patching.
6. Remove completely materials as indicated on the drawings and as required for new construction. Edges and faces of demolished areas shall be repaired to accept neat installation of new construction or finishes. Where existing materials are to be replaced, existing materials, adhesives, etc. shall be removed and exposed surfaces shall be repaired as recommended by manufacturer prior to installation of new materials.
7. Patch all existing holes and voids and patch holes caused by the removal of equipment, piping, conduit, duct, grills, etc with materials matching existing.
8. Where Finish Schedule shows existing finishes to remain, these finishes to be repaired and/ or extended to be seamless with renovated areas.
9. Surfaces of new and existing finishes are to match in color, texture and consistency, unless noted otherwise.
10. Contractor is responsible for rerouting any existing conduits, wiring, plumbing and piping as required to achieve the desired layout and design intent shown. New rerouting locations shall be concealed within wall. When it is impossible to conceal items, locate items tight against walls- enclose items with gypsum wall board without disruption of service to other areas.
Other General Requirements
General Notes:
Keynote List:
09 90 00.PT6 PAINT COLOR - MILLWORK
10 28 00.BH BATH DOUBLE HOOK
10 28 00.TP TOILET PAPER HOLDER
10 44 00.2AS 2A FIRE EXT AND SEMI RECESSED
CABINET
12 24 00.WB WINDOW BLINDS
12 24 00.WS2 WINDOW SHUTTERS
21 50 00.CH CONCEALED SPRINKLER HEAD
21 50 00.FC FIRE PROTECTION COMPONENT
21 50 00.HS HORIZONTAL SIDEWALL SPRINKLER
22 40 00.LV LAVATORY
22 40 00.P PLUMBING COMPONENT
22 40 00.WC WATER CLOSET
23 37 13.DF HVAC DIFFUSER
23 80 00.D DUCTWORK
26 10 00.ED ELECTRICAL DEVICE
26 50 00.LF LIGHTING FIXTURE
08 14 33.HR HISTORIC REPLACEMENT WOOD DOORS
08 31 00.AP ACCESS PANEL
08 71 00 DOOR HARDWARE
08 80 00.S3 SINGLE SAFETY GLAZING
09 21 00.PR PLASTER REPAIR
09 21 16.AI ACOUSTIC INSULATION
09 21 16.CL GYPSUM WALLBOARD-CEILING
09 21 16.CM COVE MOULDING
09 21 16.GA GYPSUM BOARD ASSEMBLY
09 21 16.MC METAL CEILING FRAMING
09 21 16.MS METAL STUD WALL FRAMING
09 21 16.SM GYPSUM STEP MOULDING
09 30 00.T3 WALL TILE
09 30 00.T4 BACKSPLASH TILE
09 51 00.ACT ACOUSTICAL CEILING TILE A
09 64 29.WF CHESTNUT WOOD FLOOR
06 20 00.LT LIGHT TROUGH
06 20 00.M MIRROR
06 20 00.PR WOOD PICTURE RAIL
06 20 00.WB WOOD BASE
06 20 00.WDF WOOD DOOR FRAME
06 20 00.WS WOOD WAINSCOT
06 20 00.WW WOOD INTERIOR WINDOW
06 41 00 ARCHITECTURAL WOOD CASEWORK
06 41 00.G GROMMET
06 41 00.POT PULL OUT TRASH
06 41 00.SAS ADJUSTABLE SHELF SUPPORTS
06 41 00.SB SUPPORT BRACKET
06 41 00.SS SOLID SURFACING COUNTERTOP
06 41 00.WC WOOD COUNTERTOP
06 41 00.WOC WOOD CABINETS
07 90 05.S SEALANT
01 60 00.OD OSCI DISHWASHER
01 60 00.OM OSCI MICROWAVE
01 60 00.OR OSCI REFRIGERATOR
01 60 00.OSC OSOI SECURITY DEVICE
01 73 20.SD SELECTIVE DEMOLITION
01 73 20.TA 9x9 ASBESTOS TILE ABATEMENT
04 43 01.MS MARBLE STONE TRIM AND
REFURBISHMENT
05 91 00.CW HISTORIC TREAMENT OF ORNAMENTAL
METALS
06 10 00.B BLOCKING
06 20 00.CM WOOD CROWN MOLDING
06 20 00.CR WOOD CHAIR RAILS
06 20 00.DC WOOD DOOR CASINGS
06 20 00.HP1 PLYWOOD TYPE 1
06 20 00.HW1 HARDWOOD LUMBER 1
4 82 16
Renovated Area:
3175 sf
Occupant Load: (LSC 7.3.1.2) Business: 100 gross sf/person Storage: NA
Fifth Floor:
Business = 32 people
Egress Capacity: (LSC 7.3.3) Stairs: 0.3" / person
Level components and ramps: 0.2"/per Maximum Travel Distance: (LSC 7.6.1)
Business: 300 ft Storage: NA
Maximum Dead End Limit: (LSC 7.6.1) Business: 50 ft Storage: NA
Maximum Common Path of Travel: (LSC 7.6.1) Business: 100 ft Storage: NA
Building Component Ratings:
Structural Frame: 0 hrs Bearing Walls: 0 hrs Nonbearing walls: 0 Floor Construction: 0 hrs Roof Construction: 0 hr
Rated Separations:
Shaft enclosure: 2 hr
Corridors: 2 hr Interior Finish Limitations:
Class A or B in all spaces, except Exits Class A in Exits
APPLICABLE CODES & STANDARDS
- International Building Code, 2018 Edition
- National Fire Protection Association (NFPA) 101 Life Safety Code (LSC), Latest Edition
- Facilities Standards for the Public Building Service- PBS-P100, 2018 Edition.
- Architectural Barriers Act Accessibility Standard (ABAAS), Latest Edition.
- US Courts Design Guide, Latest Edition.
1. The Contractor shall supervise and direct the work, using the Contractor’s best skill and attention.
The Contractor shall be solely responsible for, and have control over, construction means, methods, techniques, sequences, and procedures and for coordinating all portions of the Work. If the Contract Documents give specific instructions concerning construction means, methods, techniques, sequences, or procedures, the Contractor shall evaluate the jobsite safety thereof, and shall be fully responsible for the jobsite safety associated with such instructions. If the Contractor determines that such instructions may not be safe, the Contractor shall give timely written notice to the Owner and Architect and shall not proceed with that portion of the Work without further written instructions from the Architect.
2. The Contractor shall employ a competent superintendent and necessary assistants who shall be in attendance at the Project site during performance of the Work. The superintendent shall represent the Contractor and communications given the superintendent shall be binding as if given to the Contractor.
3. Demolition debris shall be removed from the site daily. Contractor shall clean jobsite daily, maintain a clean workplace and keep construction debris and dust away from adjacent building occupants.
4. Install blocking in all walls indicated to receive wall mounted devices and/ or cabinetry.
5. All wood blocking shall be fire retardant treated.
6. Provide double studs at all openings in walls.
7. Not used.
8. All vertical rated mechanical chase assemblies shall extend from floor finish to structure above.
10. All exposed electrical, fire protection, and mechanical devices shall be centered on or align with architectural features as shown on the Reflected Ceiling Plans.
11. Openings created in slabs, smoke partitions, or fire rated partitions by this work shall be repaired using techniques and materials to maintain the rating of the wall, including but not limited to, smoke dampers, fire dampers, firestopping, and fire safing, penetrations of masonry walls and concrete floors shall be stopped to minimum 2 hour rating.
12. Contractor is to coordinate with Owner provided materials & services, including: Security equipment.
13. All dimensions are to face of finished surfaces, unless noted otherwise.
14. Relocate existing Fire Sprinkler mains, branches, and heads to accomodate specified ceiling heights, ceiling configuration, and lighting layout.
G002 1/8" = 1'-0" 2 Second Floor- Life Safety Plan
MAX COMMON PATH OF
TRAVEL: 100'-0"
ACTUAL COMMON PATH OF
TRAVEL: 95'-0"
DOOR CAPACITY: 180 PPL
DOOR LOAD: 32 PPL
Revision Number
Revision Date Revision Description
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
NORTH
4" V
2" HW
3" CW
4" S
3" EX STANDPIPE
3" V
5" V
2" S
DEMOLISH 2" S DEMOLISH 4" V
4" S ABOVE
4" V 2" S
Floor Drain
2" S
2" S
4" S Active
2" Wet Vent
TOILET
ABOVE
Demo Telephone Closet
EXISTING ELECTRICAL
PANEL
Law CLerk - 139sf Judge's Chambers - 468sf Judicial Assistant - 260sf
Law Clerk - 158sf
Judge's Toilet 26sf
Staff Attorney - 140sf
Closet - 29sf
Breakroom - 124sf Workroom - 91sf Law Clerk - 150sf Law Clerk - 118sf
Vestibule - 243sf
Hallway - 58sf
Library - 374sf
Staff Toilet 27sf
Staff Toilet 32sf
Closet 14sf
Closet 8sf
Closet 8sf
Closet 11sf
Closet - 13sf
Hallway - 400sf
Mechanical - 212sf
Replace Door, Keep Frame
REMOVE
BOOKSHELVES
NOTE 4 NOTE 5
REMOVE AND
SALVAGE FOR
REUSE EXISTING
MARBLE TRIM /
WALL PANELS
1 1
9 9888 8 8 8 8
10 10 10
COORDINATE WALL
DEMOLITION WITH
NEW WALL
INSTALLATION
04 43 01.MS
04 43 01.MS
11 11
Mosaic Tile
Presumed Asbestos Containing Tile Under Existing Finish
Marble Under Existing Finish
Unkown Underlayment
FILL PATTERN LEGEND
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt
3/18/2021 1:15:25 AM
AD100
01/29/21 Consolidated Set
Second Floor Demolition Plan
GB
GW
GS-04-P-15-BV-D-7018
GS-04P-13-BV-D-0009/47PE0218F0142
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1696691 Brandy Nabors
Resident Judge’s Chambers on 2
Interior renovation of Court of Appeals Judge's Chambers on second floor
2 41 8
1. Remove existing carpet/wood flooring, padding, plywood underlayment, and abate 9x9 asbestos tile/mastic if present. Remove original hardwood floor back to existing concrete slab. Original wood sleepers embedded in slab to remain. Remove wall covering, ACT ceiling, lighting, all abandoned piping and all abandoned conduit, as exists.
2. Remove existing carpet, padding and other layers to expose existing marble underlayment. In areas to receive new carpet, investigate suitability of marble as carpet underlayment. Review findings with Architect and Owner while uncovered. Remove unsuitable marble as directed. Bid to include removal of up to 200sf of area of marble flooring. Remove ACT ceiling, lighting, all abandoned piping and all abandoned conduit, as exists.
3. Existing Electrical Panel to be relocated, refer to Electrical drawings for details.
4. Protect existing door to remain during construction. Remove card reader and intercom.
5. Existing electrical conduit, data and security equipment to remain. Protect equipment from dust and debris, in coordination with the Tenants IT department representative.
6. Existing drawings/prior renovations indicate wall at area shown may be composed of 2 masonry walls with an opening through floor between. Walls not believed to be structural. Contractor to perform only investigative demolition and coordinate with Owner, building managers and architect prior to undertaking demolition in this area. Demolish all existing vertical chase ducts.
7. Remove existing fixture, see Plumbing Drawings.
8. Remove existing wall base trim, chair rail, crown moulding, window trim, sills and door casings, unless otherwise noted.
9. Remove existing base cabinets, countertop and wall cabinets in the existing workroom and breakroom.
10. Existing Floor boxes in ceiling from 3rd Floor Chambers to remain. Reroute conduit to achieve new ceiling design intent.
11. Existing window trim, sills to remain.
12. Verify transfer air requirements described in note 11 / M200 are met. If minimum required free area is not available, review findings with Architect. Cut masonry openings above ceiling up to the structure, as directed.
04 43 01.MS MARBLE STONE TRIM AND REFURBISHMENT
A. Relocate existing Fire Sprinkler mains, branches, and heads to accomodate specified ceiling heights, ceiling configuration, and lighting layout.
B. Contractor to seal, caulk, and in-fill any existing and new penetrations or openings at all walls located within the scope of work area as required for completely acoustically sealed condition both sides, typ.
C. Contractor is responsible for rerouting any existing conduits, wiring, plumbing and piping as required to achieve the desired layout and design intent shown. New rerouting locations shall be concealed within wall. When it is impossible to conceal items, locate items tight against walls-enclose items with gypsum wall board without disruption of service to other areas.
D. At all exterior walls or where existing perpendicular walls or trim are removed, scrape plaster only to the extent needed to stabilize for reskim-coating plaster finish or furring as required by new construction.
E. Existing Ballistic Window Panels shall be removed, tagged for location, and salvaged for reinstallation. Existing window trim, jamb, sill and aprons to be removed at all windows.
A. Remove and abate asbestos containing 9x9 tile and mastic, where present, below the existing carpet and padding. It is estimated that approximately 2200 square feet of tile are present but the exact quantity is unknown. Report of Limited Pre-Renovation Asbetos Containing Material and Lead Based Paint Sampling for Tuttle Second Floor Renovations, Nova Project No.3018010 09/24/18 is available as Appendix to these Contract Documents.
B. Hazardous material samplying has identified lead based paint on the existing plaster walls and plaster ceilings. Scheduled removal of walls should be done in accordance with OSHA 1926.62 regulations governing lead-safe practices. Lead based paint in ceilings and existing to remain walls shall be abated via encapsulating paint. The contractor shall prepare for encapsulation by removing loose and flaking paint by wet scraping. Refer to 09 9020.
C. For LBP abatement, the means and methods for worker protection and monitoring, are the sole responsibility of the contractor. The contractor shall comply with current OSHA 1926.62 lead regulations for lead safety related to occuapational hazards.
D. Abate all existing piping within scope of work wrapped in asbestos containing materials, known as Thermal System Insulation (TSI).
ABATEMENT NOTES
AD100 1/4" = 1'-0"
1 Second Floor- Demolition
SHEET SPECIFIC NOTES
MATERIAL KEYNOTES
GENERAL NOTES
Revision Number
Revision Date Revision Description
TYPE SR
HISTORIC
REPLACEMENT STILE &
RAIL DOOR
TRIM/ MOLDING
PROFILE TO MATCH
HISTORIC DOORS
DOOR HARDWARE,
SEE 08 7100
TYPE SRG
HISTORIC REPLACEMENT
STILE & RAIL GLASS
DOOR
GLUE CHIP GLAZING
PROFILE TO
MATCH HISTORIC
DOORS
DOOR HARDWARE,
SEE 08 7100
PROFILE TO
MATCH HISTORIC
DOORS
PROFILE TO
MATCH HISTORIC
DOORS
RAISED PANEL TO
MATCH HISTORIC
DOORS
STILE AND RAIL DOOR08 14 33
WOOD DOOR FRAME06 20 00
COLD-FORMED METAL FRAMING05 40 00
Box Beam Header
GYPSUM BOARD ASSEMBLIES09 21 16
Typ. Ea. Side
BLANKET INSULATION07 21 00
COLD-FORMED METAL FRAMING05 40 00
3 5/8" Mtl. Stud Wall
TYPICAL HEAD / JAMB DETAIL @ WOOD FRAME
TYPE
PER WALL
WOOD BLOCKING06 10 00
WOOD DOOR CASING06 46 00
See Door Schedule for Casing Type
TYPE CW
Historic Refinished Copper Exterior Window. Window to receive new trim, jamb, sill and apron. Refer to AI001 for profiles and finish.
TYPE W
Wood Window, See typical Interior Jamb, Head, and Sill details this sheet. Refer to Schedule for Casing Type.
08 80 00.S3
TYPE CWT
Same as CW. Existing window trim, sills, jamb, apron to remain.
BLANK
RA
TI
N G
(IF
A N
Y)
M
S
F
H
D i
BLANK
TY
PE
O F
W A
LL
SI
ZE
O
F U
IT
(M
A
SO
RY
O
R
ST
U D
SP
EC
IA
L
NO SPECIAL PROPERTIES
ACCOUSTIC
8" STUD OR 8" BLOCK
6" STUD OR 6" BLOCK
3-5/8" STUD
2-1/2" STUD
7/8" HAT CHANNEL
DOUBLE STUD
SHAFT
FURRING
STUD
MASONRY
3 HOUR
2 HOUR
1 HOUR
NO RATING
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
GENERAL NOTES
SHEET SPECIFIC NOTES
MATERIAL KEYNOTES
C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt
3/18/2021 1:13:10 AM
A020
01/29/21 Consolidated Set
Partition, Door, Window Types and Schedules gb
GW
GS-04-P-15-BV-D-7018
GS-04P-13-BV-D-0009/47PE0218F0142
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1696691 Brandy Nabors
Resident Judge’s Chambers on 2
Interior renovation of Court of Appeals Judge's Chambers on second floor
Door Number Type
Door Frame Casing Type
Fire Rating Hardware Set Access
Control CommentsWidth Height Material Material 270 SR 3' - 0" 7' - 6" Existing Existing Existing HW-1 271 SR 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-9 Yes 272 SR 3' - 0" 6' - 8" 08 1433.HR Existing Existing HW-2 Field Verify existing frame size to accomodate new door.
275 SRG 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-8
276 SRG 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-8
277 SRG 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-8
278 SRG 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-8
279 SRG 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-7
280 SR 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-6 Acoustic Rating STC 55.
281 SR 3' - 0" 7' - 6" Existing Existing Existing HW-3 Existing 283 SR 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-4 Acoustic Rating STC 55.
284 SR 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-4 Acoustic Rating STC 55.
285 SR 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-5 Acoustic Rating STC 55.
Door Schedule:
Door Types:
A. Hardware shown on door types are for location purposes. See specifications for required hardware.
B. See Door Schedule for material of door types.
C. See Finish Schedule for finish of door frames.
D. See AI002 for Door Casing / Frame Types. For Casing Profiles, refer to AI001 and AI001 for finish.
F. CW and CWT Windows to receive salvaged ballistic windows and new Wood Shutters, per Section 12 2400 and AI002. All other windows to receive wood blinds, per Section 12 2400.
Typical Door Details:
Type Mark Window Material Height Width Finish Glazing
CommentsType CW Refurbished to match building standard copper. Manufacture and install window shutter
Existing Strip existing paint and reburbish historic copper on inter ior side to match building standard on 3rd floor chambers.
CWT 05 91 00.CW 7' - 11" 4' - 5" Refurbished to match building standard copper. Manufacture and install window shutter
Existing Strip existing paint and reburbish historic copper on inter ior side to match building standard on 3rd floor chambers.
EX Existing 5' - 4" 4' - 5" Paint PT-6 Existing W1 06 20 00.WW 3' - 11" 4' - 6" Paint PT-6 Type 1 Float, per 08 8000 Fixed Picture Window, Window Casing Trim 1x3 Hardwood W21 06 20 00.WW 7' - 0" 3' - 0" Paint PT-6 Type 1 Float, per 08 8000 Hinged Picture Windows, Window Casing Trim, See WC-1 AI002
Window Schedule:
08 14 33.HR HISTORIC REPLACEMENT
WOOD DOORS
08 31 00.AP ACCESS PANEL
08 71 00 DOOR HARDWARE
08 80 00.S3 SINGLE SAFETY GLAZING
Window Types
Partition Schedule:
Type Mark Width Graphic Rating UL# Description Comments
EX
F1 1 1/2" Interior: 7/8" 20 gauge metal hat channel @ 16" o.c. w/ 1 layer of
5/8" gypsum board. See Wall Finish Schedule for finish material.
F1.5 2 1/8" Interior: 1 1/2" 20 gauge metal stud @ 16" o.c. w/ 1 layer of 5/8" gypsum board. See Wall Finish Schedule for finish material.
F2 3 1/8" Interior: 2 1/2" 20 gauge metal stud @ 16" o.c. w/ 1 layer of 5/8" gypsum board. See Wall Finish Schedule for finish material
S3 4 7/8" Interior: 3 5/8" 20 gauge metal stud @ 16" o.c. fill cavity 3" S.A.B, w/ 1 layer of 5/8" gypsum board on EACH side. See Wall Finish Schedule for finish material.
S3i 6 1/8" Interior: 3 5/8" 20 gauge metal stud @ 16" o.c. fill cavity 3" S.A.B, w/ 2 layers of 5/8" gypsum board on EACH side. Wall shall extend up to underside of existing slab above, where not required to provide opening for return air per M200. STC 35 rated acoustic insulation.
See Wall Finish Schedule for finish material.
Varies Varies
Wall Type Legend:
Interior Window Jamb
Interior Window Head / Sill
Revision Number
Revision Date Revision Description
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
03/26/19
PROVIDE
CASING AS
SCHEDULED IN
WINDOW
SCHEDULE
PROVIDE CASING AS
SCHEDULED IN
WINDOW SCHEDULE
F.E.C.
CALLED
NORTH
A702
G2
A702
F7
A703
G7
A701G7
A700
A7
A700
A2
A703
J2
A704F7
A700 K5
A700G5
A4
G4
A1
A7
M7
A7
M7
A4
K4
A2
G2
A7
A704 F4
A4 A704 A2
Judge
Judicial Assistant
Breakroom 281 Workroom
Law Clerk 276 Law Clerk
Law Clerk
Mechanical
Judge Toilet
Toilet
Library
Law Clerk 275 Staff Attorney
REF
D W
12' - 3" F.V. 14' - 10" 12' - 6" 20' - 6"
15' - 7" F.V.11' - 6"
Intern
6'
3"
11' - 6" F.V. 11' - 7" F.V.11' - 7"
Stair
AREA NOT IN
SCOPE
A4
EX
CWTCWCW
CWT
CWT
CW
W1 W1 W1W1
CW
W21W21
A300 A7
A300 A1
C.O.
3' - 0"
C.O.
3' - 0"
C .O
3'
0"
6' - 3" 3' - 6"
8'
9"A2
C.O.
3' - 0"
S3
S3
S3i
S3i
S3i
S3i
S3i
S3i
S3i
S3
S3
S3
S3
S3
S3
S3
S3
S3i
S3i
EX
EX
S3
F1.5
8'
3"
A702G4
4' - 7" 7' - 1 5/8"
2' - 0". 4' - 6" 1' - 6" 3' - 0" 1' - 6" 3' - 0" 2' - 0" 4' - 6" 3' - 9 7/8" 4' - 6" 2' - 0" 3' - 0" 1' - 6" 3' - 0" 2' - 0" 4' - 6" 3' - 8" 3' - 0" 1' - 6"
12' - 1" F.V.
2' - 9" A702
G5
A511 F2
A700
A5
K2
F2
A704F4
SI
M
A4SIM.
A704 F7
SI
M
A7SIM.
A7
A500
EX EX EX
A6
A501
35° 35
3' - 4 1/2" 3' - 4 1/2"
01 60 00.OR
01 60 00.OD
8' - 8" 1' - 0"
04 43 01.MS
04 43 01.MS
04 43 01.MS
04 43 01.MS
04 43 01.MS
5'
8"
NOTE 1
A501
E6
A501 E6
F2
F2
8"
8"
F2
F1
NOTE 1 A511K2
A511 F2
SI
M
A511F2
SI
M
A511K2
SI
M
A511 K2
SI
M
EQ EQ
6'
0"
A702
N2
A702 G4
SI
M
10 44 00.2AS
A6
A501
NOTE 2NOTE 2
8' - 10"
3'
9" 2' - 8"
4' - 0"
CDZ
CDZ
CDZ
BC
BC
CWR
CWJ
CWJ
CWJ
VJS
CBR
CBR
12 24 00.WB
12 24 00.WB
12 24 00.WB
12 24 00.WB
12 24 00.WB 12 24 00.WB 12 24 00.WB
.BC
.BC
BC
BC
Outer Vestibule
Inner Vestibule
S3i
F1
F1
S3
F1 F1
F1
F1
F1F1F1
F1 F1.5
2' - 2"
F1 F1.5
NOTE 3, TYP.
NOTE 3, TYP.
09 21 00.PR
AT REMOVED
DEVICES
04 43 01.MS
F1
09 21 00.PR09 21 00.PR
.P R
F2
F2
CBR
IC
CR
IC RR
IC
RR
CR (EXIST)
ALIGN
NOTE 4
12 24 00.WS2
12 24 00.WS2
12 24 00.WS2
12 24 00.WS212 24 00.WS212 24 00.WS212 24 00.WS2
NOTE 5
NOTE 5
A703
SECURITY SYMBOL LEGEND
IC
RR
CR CARD READER
DOOR LOCK REMOTE RELEASE BUTTON
INTERCOM TERMINAL
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES
C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt
3/18/2021 1:13:14 AM
A100
01/29/21 Consolidated Set
Second Floor New Plan
GB
GW
GS-04-P-15-BV-D-7018
GS-04P-13-BV-D-0009/47PE0218F0142
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1696691 Brandy Nabors
Resident Judge’s Chambers on 2
Interior renovation of Court of Appeals Judge's Chambers on second floor
01 60 00.OD OSCI DISHWASHER
01 60 00.OR OSCI REFRIGERATOR
04 43 01.MS MARBLE STONE TRIM AND REFURBISHMENT
09 21 00.PR PLASTER REPAIR
10 44 00.2AS 2A FIRE EXT AND SEMI RECESSED CABINET
12 24 00.WB WINDOW BLINDS
12 24 00.WS2 WINDOW SHUTTERS
2 41 8
A. COORDINATE LOCATIONS OF GROMMETS FOR CASEWORK WITH OWNER'S REPRESENTATIVE.
B. REINSTALL EXISTING BALLISTIC WINDOWS IN ORIGINAL WINDOW OPENINGS. COORDINATE NEW WINDOW TRIM AND CASING WITH EXISTING
BALLISTIC WINDOW SIZES.
A100 1/4" = 1'-0" A2 Second Floor- New
Revision Number
Revision Date Revision Description
1. USE SALVAGED MARBLE PANELS AND TRIM FOR NEW MARBLE HEADER AND CASING. CUT SALVAGED
MARBLE AS NECESSARY TO ACHIEVE DESIGN INTENT.
2. SHARED WINDOWS TO BE HINGED PICTURE WINDOWS. WINDOWS TO RECEIVE 3 HINGES AND
CASEMENT LOCKING HARDWARE AT THE JAMBS.
3. APPROXIMATE EXTENT OF EXISTING CHASE REQUIRING FLOOR INFILL. SEE DEMO PLAN.
4. CENTER FIRE EXTINGUISHER CABINET ON WALL. TOP OF CABINET AT 48". CENTER POWER AND DATA
OUTLETS ON WALL AT 60"
5. VERIFY LOCATION WITH ARCHITECT BEFORE INSTALLING
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
03/26/19
Resident Chambers Casework Types Type Mark Description Finish Keynote Comments
BC Bookcases, Library Island Casework Refer to Casework Schedule 06 4100 CBR Casework Breakroom Refer to Casework Schedule 06 4100 06 41 00.WOC CDZ Credenzas and Wall Shelves Refer to Casework Schedule 06 4100 06 41 00.WOC CWJ Casework Judge Refer to Casework Schedule 06 4100 06 41 00.WOC CWR Casework Workroom Refer to Casework Schedule 06 4100 06 41 00.WOC VJS Vanity Judge and Staff Refer to Casework Schedule 06 4100 06 41 00.WOC
1' - 10"
MARBLE HALF
ROUND WALL
CAP, TYPICAL
2' - 0"
4'
0"06 20 00.M
A7
A512SIM.
K7
A300
ADA NOTE 4
1' - 4" 1' - 4" 1' - 4" 1' - 5"
5" 06 41 00.SS
26 50 00.LF
7'
6"
1' - 5" . 1' - 4"
A7
A512 K4
A512
D7
A512
TRASH
C4
A512
5' - 10"
PAPER
TOWEL
DISPENSER
K7
A300
TYP.
OF FIXTURE AND DEVICE
26 10 00.ED
TYP.
ADA
IN FACE OF
CABINET
8" 8"
06 20 00.M
6'
8"
2' - 0"
4'
0"
22 40 00.WC
10 28 00.TP
06 20 00.M
06 41 00.WOC
26 10 00.ED
06 20 00.CM
K7
A300
06 10 00.B
NOTE 4
22 40 00.WC
4'
0"
06 20 00.CM06 20 00.CM
CW
12 24 00.WS2
MARBLE HALF
ROUND WALL
CAP, TYPICAL
06 20 00.CM
EQEQ
10 28 00.BH
Judge Toilet
NOTE 3
1' - 7"
C O
UN
TE
R
5'
4"
22 40 00.WC
10 28 00.TP
06 20 00.M
26 10 00.ED
26 50 00.LF
04 43 01.MS
26 10 00.ED
26 10 00.ED
NOTE 1
NOTE 1
NOTE 2
Toilet
22 40 00.WC10 28 00.TP
1' - 4"
NOTE 2
ADJACENT FINISH
WHERE PRESENT
3/4"
PANEL MOULDING.
P&P PM-2149
MIRROR SURFACEALIGN
06 20 00.M
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
GENERAL NOTES
SHEET SPECIFIC NOTES
MATERIAL KEYNOTES
C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt
3/18/2021 1:13:27 AM
A300
01/29/21 Consolidated Set
Enlarged Bathroom Plans / Elevations gb
GW
GS-04-P-15-BV-D-7018
GS-04P-13-BV-D-0009/47PE0218F0142
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1696691 Brandy Nabors
Resident Judge’s Chambers on 2
Interior renovation of Court of Appeals Judge's Chambers on second floor
1 2 4
04 43 01.MS MARBLE STONE TRIM AND
REFURBISHMENT
06 10 00.B BLOCKING
06 20 00.CM WOOD CROWN MOLDING
06 20 00.M MIRROR
06 41 00.SS SOLID SURFACING COUNTERTOP
06 41 00.WOC WOOD CABINETS
10 28 00.BH BATH DOUBLE HOOK
10 28 00.TP TOILET PAPER HOLDER
12 24 00.WS2 WINDOW SHUTTERS
22 40 00.WC WATER CLOSET
26 10 00.ED ELECTRICAL DEVICE
26 50 00.LF LIGHTING FIXTURE
A300 1/2" = 1'-0" E1 Toilet Elevation East
A300 1/2" = 1'-0" J1 Toilet Elevation South
A300 1/2" = 1'-0" G7 Judge's Toilet Elevation East
A300 1/2" = 1'-0" A4 Judge's Toilet Elevation North
A300 1/2" = 1'-0" E4 Judge's Toilet Elevation West
A300 1/2" = 1'-0" J4 Judge's Toilet Elevation South
A300 1/2" = 1'-0" A7 Judge's Bathroom Plan
A300 1/2" = 1'-0" A1 Enlarged Staff Toilet Plan
1. INSTALL ELECTRICAL RECEPTICLE
WITHIN MILLWORK AT 44" ABOVE
FINISHED FLOOR.
2. REFURBISHED MARBLE OR NEW TILE
TO EXTEND WALL TO WALL AND
BELOW NEW FIXTURES AND
CASEWORK.
3. DIMENSION IS BETWEEN CENTERLINE
OF TOILET AND FACE OF WINDOW
TRIM.
4. BLOCKING FOR FUTURE ADA GRAB
BAR AT 35" AFF
Revision Number
Revision Date Revision Description
ST
ATE OF GEORGI A
RE GI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
03/26/19
A300 3" = 1'-0"
K7 MIRROR FRAME DETAIL
NORTH
RECESSED
LIGHT FIXTURES
HVAC
SUPPLY
DIFFUSER
PENDANT
SPRINKLER
HEAD
ACCESS PANELCASEWORK
SIDEWALL
SPRINKLER
HEAD
HVAC
RETURN
DIFFUSER
PENDANT
LIGHT FIXTURES
SURFACE MOUNTED
LIGHT FIXTURES
EXIT SIGN
A4
A500
Breakroom
Workroom
Judicial Assistant
Judge
Library
Judge Toilet
Toilet
Staff Attorney
Law Clerk
Law Clerk
Law Clerk
Law Clerk
Mechanical
Intern
AREA NOT IN
SCOPE OF WORK
AREA NOT IN SCOPE OF WORK
AREA NOT IN
SCOPE
200c
A300 A7
10' - 3 1/2"
9' - 0"
8' - 6"
8' - 6"
10' - 3 1/2"
10' - 2 1/2" 9' - 8"
9' - 10"
8' - 6"
9' - 2" 9' - 1"
10' - 3 5/8"
10' - 4 1/2"
9' - 0"
9' - 0"
10' - 3 1/2"
9' - 3"
9' - 4"
8' - 6" 10' - 5"
8' - 6"
9' - 8"
8' - 6"
8' - 6"
9' - 6"
8' - 6"
9' - 6"
8' - 6"
9' - 6"
8' - 6"
9' - 0"
10' - 3 1/2"
9' - 8"
9' - 0"
7' - 9" 8' - 6"
9"
1' - 1"
9"
EQ EQ
A7
A500
F7
A500 M7
A500
A2
A500
J2
A500
8' - 6"
5'
3/
8"
6'
0"
EQ
EQ
EQ EQ EQ
A6
A501
9"
10' - 3 1/2"
4' - 0" EQ1EQ1
EQ
EQ
7'
2"
5'
1" 3'
6"
8' - 2" F.V. EQ2 4' - 0". EQ2
06 20 00.CM
04 43 01.MS
5'
0" 5'
0"
06 20 00.LT
06 20 00.LT
2' - 0" 1' - 0" F.V. 1' - 0" 2' - 0"
2'
0" F.
V
2'
0"
1' - 2" 3' - 0" 1' - 2"
2'
0"
5' - 3"
3'
6"
26 50 00.LF
EQ1 EQ1
9' - 8"9' - 8"
06 20 00.CM
06 20 00.CM
9' - 6"
9' - 6"
9' - 11"9' - 11"
8' - 2"
NOTE 1
09 21 16.CL
09 21 16.CL
09 21 16.CL
21 50 00.CH
21 50 00.HS
23 37 13.DF
8'
3"
EQ
EQ
1' - 2" 3' - 11"
12 24 00.WS2
12 24 00.WS2
12 24 00.WS212 24 00.WS212 24 00.WS212 24 00.WS2
12 24 00.WS2
08 31 00.AP
1'
2"
9' - 9"
9' - 11"
8' - 6"
8' - 2"
1'
0" 1' - 0"
8 3/4"
EQ
EQ
2'
6"
9' - 10"9' - 11" 8' - 6"
8' - 6"
EQ EQ
3' - 4" 8" 2' - 8"
3'
4'
1"
4' - 8" 3' - 11"
3' - 0" 2' - 10"
1'
2"
2' - 2"
3' - 0"
2' - 10" 2' - 10"
4'
1" 4'
1"3' - 4"
EQ
EQ
EQ
A
LI
G N
A
LI
G N
A
LI
G N
A
LI
G N
8"
8"
1'
1"
8' - 6"
2' - 8"
1' - 1"
09 21 16.AI
NOTE 2
09 21 16.AI
NOTE 2
OF
OPENING
09 21 16.AI
NOTE 2
2'
4" 2'
4"
2' - 4" 2' - 8"
OF
WINDOW
23 37 13.DF
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES
C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt
3/18/2021 1:13:35 AM
A400
01/29/21 Consolidated Set
Second Floor Ceiling Plan
GB
GW
GS-04-P-15-BV-D-7018
GS-04P-13-BV-D-0009/47PE0218F0142
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1696691 Brandy Nabors
Resident Judge’s Chambers on 2
Interior renovation of Court of Appeals Judge's Chambers on second floor
09 21 16.AI ACOUSTIC INSULATION
09 21 16.CL GYPSUM WALLBOARD-CEILING
12 24 00.WS2 WINDOW SHUTTERS
21 50 00.CH CONCEALED SPRINKLER HEAD
21 50 00.HS HORIZONTAL SIDEWALL SPRINKLER
23 37 13.DF HVAC DIFFUSER
26 50 00.LF LIGHTING FIXTURE
04 43 01.MS MARBLE STONE TRIM AND
REFURBISHMENT
06 20 00.CM WOOD CROWN MOLDING
06 20 00.LT LIGHT TROUGH
08 31 00.AP ACCESS PANEL
A. ALL DIMENSIONS ARE TO FACE OF FINISHED SURFACES, UNLESS OTHERWISE NOTED.
B. SURFACES INDICATED TO BE ALIGNED OR INDICATE A CENTERLINE, ARE TO HAVE FINISH SURFACES FLUSH WITH
ONE ANOTHER.
C. COORDINATE ALIGNMENT OF FIRE SPRINKLERS WITH RECESSED LIGHT FIXTURES, AS INDICATED.
D. IT IS THE INTENT OF THE CEILING DESIGN TO MAXIMIZE CEILING HEIGHTS. MEPFP COMPONENTS SHALL BE
INSTALLED AS HIGH AS POSSIBLE TO ACHIVE DESIGN INTENT. IF NOTED CEILING HIEIGHTS CAN BE RAISED, COORDINATE WITH ARCHITECT OR OWNER REPRESENTATIVE.
Ceiling Legend
2 41 8
1. USE SALVAGED MARBLE PANELS AND TRIM FOR NEW HEADER AND CASING. CUT SALVAGED MARBLE AS
NECESSARY TO ACHIEVE DESIGN INTENT.
2. INSTALL ACOUSTIC INSULATION DIRECTLY BELOW AND IN FRONT OF TRANSFER DUCT AND WALL OPENING, INSIDE PLENUM. SEE M200 FOR DUCT AND TRASFER DETAILS.
A400 1/4" = 1'-0" A2 Second Floor RCP - New
Revision Number
Revision Date Revision Description
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
1' - 1 5/8" 5 7/8"1' - 0"1' - 0"
9' - 0"
9' - 7"
9' - 3"
1"
09 21 16.GA 09 21 16.CL
1' - 1"
9' - 0"
06 20 00.LT
1' - 0"
9' - 7"
3/ 8"
8"06 20 00.CM
09 21 16.GA
09 21 16.GA
8 7/8" 1' - 0".
9' - 0"
10' - 2 1/2"
8' - 2"
8' - 6"
1' - 0"
7' - 9"
1/
8"04 43 01.MS04 43 01.MS
5/
8"
9"
04 43 01.MS
04 43 01.MS04 43 01.MS
06 20 00.CM
04 43 01.MS
1' - 1 1/4"
10' - 5"
06 20 00.LT
9 1/8"
3' - 6"
9' - 0"
8' - 6"
9' - 6"06 20 00.CM
09 21 16.GA
06 20 00.WW
3' - 9"
06 20 00.CR
3' - 8 1/2"
23 37 13.DF
26 50 00.LF
1' - 2"
3' - 0" 1' - 2"
12 24 00.WS2
05 91 00.CW
06 20 00.LT09 21 16.CL
1' - 2"
1' - 2" 7 7/8" 8"
21 50 00.FC
09 21 16.MC
09 21 16.GA
06 20 00.LT 09 21 16.CL
9' - 1"
9' - 9"
7/ 8"
23 37 13.DF
NOTE 2
21 50 00.HS
23 37 13.DF
6' - 0"
8' - 6"
9' - 0"
1' - 9"
10' - 3 1/2"
09 21 16.GA
09 21 16.GA
09 21 16.AI
06 20 00.HP1
06 20 00.WDF
06 20 00.CM
23 37 13.DF
2 1/2" 2 5/8"
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES
C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt
3/18/2021 1:13:38 AM
A500
01/29/21 Consolidated Set
Ceiling Details
GB
GW
GS-04-P-15-BV-D-7018
GS-04P-13-BV-D-0009/47PE0218F0142
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1696691 Brandy Nabors
Resident Judge’s Chambers on 2
Interior renovation of Court of Appeals Judge's Chambers on second floor
16''3''
09 21 16.AI ACOUSTIC INSULATION
09 21 16.CL GYPSUM WALLBOARD-CEILING
09 21 16.GA GYPSUM BOARD ASSEMBLY
09 21 16.MC METAL CEILING FRAMING
12 24 00.WS2 WINDOW SHUTTERS
21 50 00.FC FIRE PROTECTION COMPONENT
21 50 00.HS HORIZONTAL SIDEWALL SPRINKLER
23 37 13.DF HVAC DIFFUSER
26 50 00.LF LIGHTING FIXTURE
04 43 01.MS MARBLE STONE TRIM AND REFURBISHMENT
05 91 00.CW HISTORIC TREAMENT OF ORNAMENTAL METALS
06 20 00.CM WOOD CROWN MOLDING
06 20 00.CR WOOD CHAIR RAILS
06 20 00.HP1 PLYWOOD TYPE 1
06 20 00.LT LIGHT TROUGH
06 20 00.WDF WOOD DOOR FRAME
06 20 00.WW WOOD INTERIOR WINDOW
1. ELEVATION OF SOFFIT IS A MINIMUM OR 1/2" ABOVE TOP OF EXISITNG WINDOW TRIM, WHICHEVER IS
HIGHER.
2. CENTER DIFFUSER RUN ON WINDOW FRAME.
A500 1 1/2" = 1'-0" M7 Library Ceiling at Judges Door
A500 1 1/2" = 1'-0" F7 Library Ceiling at Column Detail
A500 1 1/2" = 1'-0" A7 Ceiling Transition at Entry Vestibule
A500 1 1/2" = 1'-0" J2 Typical Law Clerk Soffit Detail
A500 1 1/2" = 1'-0" A2 Judge's Ceiling Transition Detail
A500 1 1/2" = 1'-0" A4 Typical Soffit Detail
Revision Number
Revision Date Revision Description
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
W21
06 20 00.WW
09 21 16.CL
06 20 00.WB
06 41 00.WC
09 21 16.GA
09 21 16.CL
WINDOW HINGES
WINDOW HINGES
EX
9' - 6"
2'
6"
1'
0"
1' - 0"1/ 4"
1'
0"
F2
09 21 16.GA
SALVAGED
MARBLE
PANELS
04 43 01.MS
09 21 16.GA
OVERHEAD
MARBLE TRIM,
SEE A7/A500
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES
C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt
3/18/2021 1:13:40 AM
A501
01/29/21 Consolidated Set
Details
Author Approver
GS-04-P-15-BV-D-7018
GS-04P-13-BV-D-0009/47PE0218F0142
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1696691 Brandy Nabors
Resident Judge’s Chambers on 2
Interior renovation of Court of Appeals Judge's Chambers on second floor
A501 3/4" = 1'-0" A6 Typ. Clerk Shared Window Detail
Revision Number
Revision Date Revision Description
A501 3" = 1'-0" E6 Typical Marble Jamb Detail
04 43 01.MS MARBLE STONE TRIM AND REFURBISHMENT
06 20 00.WB WOOD BASE
06 20 00.WW WOOD INTERIOR WINDOW
06 41 00.WC WOOD COUNTERTOP
09 21 16.CL GYPSUM WALLBOARD-CEILING
09 21 16.GA GYPSUM BOARD ASSEMBLY
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
2"
1/ 4"
1'
1/
8"
1"
1'
1/
4"
1"
1'
1/
4"
1/ 4"
4"
3'
9"
1' - 1"
06 20 00.HW1
06 41 00.WOC
06 20 00.HW1
3/4"
06 41 00.WOC
06 20 00.HW106 20 00.HW1
2' - 1"
3'
0" 2'
6"
2'
9"
8'
3"
EQ
EQ
2' - 1"
2' - 0"
2'
6" 6'
1/ 4"
06 20 00.HP1
06 20 00.HW1
06 20 00.CM
1/
2"
06 41 00.WC
1' - 0"
1/
4" 1/ 4"
4"3"
06 20 00.CM
06 20 00.HP1
FILE DRAWER
HARDWARE
1/ 4"
1/
4"
1/ 4"
N O
TE
/2
CABINET
LOCK
C
LE
A R, T
YP
1'
1"
06 20 00.HW1
06 20 00.HP1
2' - 1"
1'
6"
06 20 00.WB
1/
2"
1 1/4"
A
LI
G N
W
SI
LL
1'
6"
26 10 00.ED
1'
WOODWORK
BEYOND
EQ
'B
EQ
'B
SE
E
EL
EV
A
TIO
N
SE
E
EL
EV
A
TIO
N
3'
0"
1/
2" 1/
4"
1/
4" 1/
4"
EQ
1/ 4"
EQ
N O
TE
N O
TE
EQ
'A
EQ
'A
1/
2" T
YP
2' - 0"
1' - 1"
8'
/4
HE
IG
HT
A
D
JU
ST
A
BL
E
SH
EL
V
ES
06 20 00.HP1
TY
P
C
LE
A R
1'
3/ 4"
1' - 1 3/8"
06 41 00.SAS
1/ 4"
2' - 0"
1/
2" 1/
4"
1/
4"
SE
E
EL
EV
A
TIO
N
SE
E
EL
EV
A
TIO
N
3'
0"
2'
3/
4"
1/
2"
TY
P.4" 1'
1/ 2"
1/ 4"
1'
3/
8"
1/ 4"
1/ 4"
2" N
O
TE
N
O
TE
1"
1 1/4"
3'
8"
06 41 00.SS
06 20 00.HP1
SPACE FOR
OWNER PROVIDED
PAPER SHREDDER
26 10 00.ED
3' - 6"
1"
1 1/4"
4"
EQ
S H
EL
V
ES
2'
3/
4"
1/ 4"
2"
3'
8"
1' - 1" 06 20 00.HW1
06 20 00.HW1
06 41 00.WOC
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
GENERAL NOTES
SHEET SPECIFIC NOTES
MATERIAL KEYNOTES
C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt
3/18/2021 1:13:41 AM
A510
01/29/21 Consolidated Set
Millwork Details
Author Approver
GS-04-P-15-BV-D-7018
GS-04P-13-BV-D-0009/47PE0218F0142
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1696691 Brandy Nabors
Resident Judge’s Chambers on 2
Interior renovation of Court of Appeals Judge's Chambers on second floor
A510 1" = 1'-0" C5 Half Bookcase, Library
A510 1" = 1'-0" E5 Workroom Desk, Typical
A510 1" = 1'-0" G5 Judge Hutch at Door Cabient
A510 1" = 1'-0" J5 Judge Hutch at Drawers
A510 1" = 1'-0" C8 Extended Sill Detail
A510 1" = 1'-0" E1 Workroom Base…