SOW OPTION 1 Resident Chambers 270 CD DWGS 2021 03 17 (1).pdf

PDF 9 MB Posted

Attached to
11th Circuit US Court of Appeals- Tuttle Chambers Renovation
Solicitation number
47PE0221R0011
Issued by

About this file

This solicitation is for general construction services for the renovation of resident and non-resident judges' chambers at the Elbert P. Tuttle Federal Building in Atlanta, Georgia. The General Services Administration intends to award a firm-fixed-price contract between $1 million and $5 million through a competitive negotiation process using the Lowest Price Technically Acceptable selection procedure. The work includes renovations to two resident judge chambers and four non-resident judge chambers to accommodate the Court of Appeals. The contract is set aside for small businesses. Offerors must submit technical and price proposals, which will be evaluated separately. At the conclusion of the solicitation phase, GSA intends to award a single contract to one offeror for all construction services.

View the file

Other files

File Type Posted
Solicitation Amendment 47PE0221R0011 0002.pdf PDF
solicitation 24 August 2021.pdf PDF
solicitation 24 August 2021.pdf PDF
Solicitation Amendment 47PE0221R0011 0002.pdf PDF
Solicitation Amendment 47PE0221R0011 0002.pdf PDF
solicitation 24 August 2021.pdf PDF
Answered RFIs 15 June 2021.xlsx XLSX spreadsheet
Amendment 1442 15 June 2021.pdf PDF
Tab 5 Wage Determination 26 April 2021.pdf PDF
SOW OPTION 2 Resident Chambers 450 and Non Resident Chambers 442 CD DWGS 2021 03 17 (2).pdf PDF
Agreement 19 April 2021.docx DOCX document
Reps and Certs 19 April 2021.docx DOCX document
Site Visit Registration.docx DOCX document
solicitation 19 april 2021.docx DOCX document
1442 soliciation 5 May 2021.pdf PDF
1442 soliciation 5 May 2021.pdf PDF
SOW OPTION 3 Non Resident Chambers 216 CD PM 2021 03 17.pdf PDF
solicitation 19 april 2021.docx DOCX document
Bid Summary Sheet 5 May 2021.docx DOCX document
SOW OPTION 1 Resident Chambers 270 CD PM 2021 03 17 (3).pdf PDF
Agreement 19 April 2021.docx DOCX document
SOW COVER AND DIVISION 1 2021 03 14.pdf PDF
Reps and Certs 19 April 2021.docx DOCX document
SOW OPTION 2 Resident Chambers 450 and Non Resident Chambers 442 CD PM 2021 03 17 (1).pdf PDF
SOW BASE Non Resident Chambers 238 and 434 CD DWGS 2021 03 17 (1).pdf PDF
SOW OPTION 4 Non Resident Chambers 233 CD DWGS 2021 03 17 (1).pdf PDF
Site Visit Registration.docx DOCX document
SOW OPTION 4 Non Resident Chambers 233 CD PM 2021 03 17.pdf PDF
SOW OPTION 3 Non Resident Chambers 216 CD DWGS 2021 03 17 (1).pdf PDF
SOW OPTION 4 Non Resident Chambers 233 Pre-Renovation ACM and LBP Sampling Report 2021 03 17 (1).pdf PDF
SOW BASE Non Resident Chambers 238 and 434 CD PM 2021 03 17 (1).pdf PDF
SOW BASE Non Resident Chambers 216 and 238 and 434 Pre-Renovation ACM and LBP Survey Report (1).pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

KEY PLAN

CALLED

NORTH

Room name

1i

1t

A101

SIM

ROOM INDICATOR

SLOPE INDICATOR

DETAIL INDICATOR

KP

CR

SECURITY KEYPAD

SECURITY CAMERA

CARD READER ACCESS

TO BE REMOVED (DEMO SHEETS)

EXISTING TO REMAIN

NEW

HIDDEN FEATURES LINE

CENTER LINE

2 HOUR RATED WALL

1 HOUR RATED WALL

PATH OF EGRESS

EGRESS DOOR

# OF ROOM OCCUPANTS

ROOM OCCUPANCY TYPE

A #OCC.

EXIT EXIT SIGN

NORTH INDICATOR

BUILDING SECTION INDICATOR

WALL SECTION INDICATOR

BREAK LINE INDICATOR

WALL TYPE TAG INDICATOR

WINDOW TYPE TAG INDICATOR

2 41 8

GRAPHIC SCALE, 1/8" = 1'-0"

DOOR TAG INDICATOR

ELEVATION INDICATOR

CENTER LINE

M

06 41 00.PL KEYNOTE INDICATOR

(SEE PROJECT MANUAL)

0 GRID LINE

A101

SIM

INTERIOR ELEVATION INDICATOR

A101 EXTERIOR ELEVATION INDICATOR

CALLOUT INDICATOR

DRAWING TITLE

DIMENSION LINE

FIRE/HORN STROBE

MOTION DETECTOR

1 View Name A101 1/8" = 1'-0"

A101

SIM

A101

SIM

A101

1 Ref

Re f

Re f

1 Ref

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

CIVIL ENGINEER:

MEP ENGINEER:STRUCTURAL ENGINEER:

ARCHITECT:

Occupancy Type:

Construction Type:

Fire Suppression:

Project Name:Image: Project Information:

Project Team:

Drawing List:

C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt

3/18/2021 1:16:31 AM

G001

01/29/21 Consolidated Set

Cover Sheet gb

GW

Johnson Spellman & Assoc.

350 Research Court Suite 130 Peachtree Corners, GA 30092 678.336.5427

Westside Engineering 5525 Interstate North Parkway- Suite 200 Atlanta, GA 30328 404.965.1287

Houser Walker Architecture 1819 Peachtree Rd NE Suite 102 Atlanta, GA 30309 404.633.4264

Resident Judges Chambers on 2 Elbert P. Tuttle Court of Appeals 56 Forsyth St. NW Atlanta, GA

Existing, Business

Existing 1B (IBC) ; Type II (LSC)

Existing, Sprinklered

GS-04-P-15-BV-D-7018

GS-04P-13-BV-D-0009/47PE0218F0142

56 Forsyth Street Atlanta, Georgia

GA00088ZZ

N1696691 Brandy Nabors

Resident Judge’s Chambers on 2

Interior renovation of Court of Appeals Judge's Chambers on second floor

Number Sheet Name 01 /2

9/

C on so lid at et

S et

C ur re nt

R ev isi on

G GENERAL

G001 Cover Sheet O G002 General Notes, Life Safety & Keynote List O

AD ARCHITECTURAL DEMOLITION

AD100 Second Floor Demolition Plan O

A ARCHITECTURAL

A020 Partition, Door, Window Types and Schedules O A100 Second Floor New Plan O A300 Enlarged Bathroom Plans / Elevations O A400 Second Floor Ceiling Plan O A500 Ceiling Details O A501 Details O A510 Millwork Details O A511 Millwork Details O A512 Millwork Details O A700 Library Elevations O A701 Judge Elevations O A702 Workroom/Breakroom Elevations O A703 Interior Elevations O A704 Interior Elevations O

AI ARCHITECTURAL INTERIORS

AI001 Second Floor Finish Schedule and Plan O AI002 Second Floor Interiors Details O AI003 Second Floor Furniture Reference Plan O

M MECHANICAL

M001 HVAC Legends and Abbreviations O M100 Second Floor HVAC Demolition Plan O M200 Second Floor HVAC New Work Plan O M400 HVAC Details O M500 HVAC Schedules, Control Sequences and I/O Summary O

ED ELECTRICAL DEMOLITION

ED200 Second Floor Demolition Plan O

E ELECTRICAL

E001 Notes Details Legend O E002 Lighting Schedule and Control Panel Riser O E100 Riser Diagram O E101 Panel Schedules O E200 Second Floor - Lighting Plan O E300 Second Floor - Power and Communications Plan O E400 Second Floor - Systems Plan O

P PLUMBING

P000 Plumbing Legend, Schedules and Notes O P200 Second Floor Plumbing Plans O

FP FIRE PROTECTION

FP200 Second Floor Fire Protection Plans O

Key: O = Current Issued NOT for Construction P = Previously Issued = Not Issued (blank) i = For Information Only

MPFP ENGINEER:ELECTRICAL ENGINEER :

Legend:

Revision Number

Revision Date Revision Description

ST

ATE OF GEORGI A

REGI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

03/26/19

F.E.C.

Judge

Judicial Assistant

Breakroom

Workroom

Law Clerk

Law Clerk

Law Clerk

Staff Attorney

Law Clerk

Mechanical

Judge Toilet

Toilet

Library

Intern

Stair

AREA NOT IN

SCOPE

200c

EX

IT

FIRE

EXTINGUISHER

CABINET

CALLED

NORTH

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt

3/18/2021 1:16:33 AM

G002

01/29/21 Consolidated Set

General Notes, Life Safety & Keynote List

GB

GW

GS-04-P-15-BV-D-7018

GS-04P-13-BV-D-0009/47PE0218F0142

56 Forsyth Street Atlanta, Georgia

GA00088ZZ

N1696691 Brandy Nabors

Resident Judge’s Chambers on 2

Interior renovation of Court of Appeals Judge's Chambers on second floor

1. The Contractor shall maintain at the site for the Owner one copy of the Drawings, Specifications, Addenda, Change Orders and other Modifications, in good order and marked currently to indicate field changes and selections made during construction, and one copy of approved Shop Drawings, Product Data, Samples, and similar required submittals.

2. The Contractor shall perform work in accordance with the Contract Documents.

3. The drawings and specifications are complimentary and are to be understood comprehensively. Organization and arrangement of the drawings and/ or specifications into divisions, sections and articles shall not control the Contractor in dividing the work among subcontractors or in establishing the extent of Work to be performed by any trade.

4. Because the Contract Documents are complementary, the Contractor shall, before starting each portion of the Work, carefully study and compare the various Contract Documents relative to that portion of the Work, shall take field measurements of any existing conditions related to that portion of the Work, and shall observe any condition at the site affecting it. These obligations are for the purpose of facilitating coordination and construction by the Contractor and are not for the purpose of discovering errors, omissions, or inconsistencies in the Contract Documents. However, the Contractor shall promptly report to the Architect any errors, inconsistencies or omissions discovered by or made known to the Contractor as request for information.

5. Drawings are not to be scaled for information.

Contract Documents Existing Conditions

1. Existing adjacent portions of the building are to remain operational throughout construction. Coordinate construction activities and phasing with Architect, GSA COR, and Tenant Representative to minimize disruptions to owner’s operations and access, and to ensure safety of occupants.

2. Attention is called to the fact that this project is a renovation of an existing building.

Renovation of existing buildings require thorough coordination of the contract documents with the existing conditions. The Contractor must verify all relevant existing conditions, dimensions, and details prior to beginning construction.

3. All drawings and details incorporating existing conditions are representations of existing conditions only. The Contractor shall verify the accuracy of actual conditions and coordinate with the Architect any deviations of the details so to execute the intent of the drawing or detail.

4. Field Verify existing dimensions prior to ordering or cutting materials.

5. Cutting and Patching: The Contractor shall be responsible for cutting, fitting or patching required to complete the Work or to make parts fit together properly. All areas requiring cutting, fitting and patching shall be restored to the condition existing prior to cutting, fitting and patching.

6. Remove completely materials as indicated on the drawings and as required for new construction. Edges and faces of demolished areas shall be repaired to accept neat installation of new construction or finishes. Where existing materials are to be replaced, existing materials, adhesives, etc. shall be removed and exposed surfaces shall be repaired as recommended by manufacturer prior to installation of new materials.

7. Patch all existing holes and voids and patch holes caused by the removal of equipment, piping, conduit, duct, grills, etc with materials matching existing.

8. Where Finish Schedule shows existing finishes to remain, these finishes to be repaired and/ or extended to be seamless with renovated areas.

9. Surfaces of new and existing finishes are to match in color, texture and consistency, unless noted otherwise.

10. Contractor is responsible for rerouting any existing conduits, wiring, plumbing and piping as required to achieve the desired layout and design intent shown. New rerouting locations shall be concealed within wall. When it is impossible to conceal items, locate items tight against walls- enclose items with gypsum wall board without disruption of service to other areas.

Other General Requirements

General Notes:

Keynote List:

09 90 00.PT6 PAINT COLOR - MILLWORK

10 28 00.BH BATH DOUBLE HOOK

10 28 00.TP TOILET PAPER HOLDER

10 44 00.2AS 2A FIRE EXT AND SEMI RECESSED

CABINET

12 24 00.WB WINDOW BLINDS

12 24 00.WS2 WINDOW SHUTTERS

21 50 00.CH CONCEALED SPRINKLER HEAD

21 50 00.FC FIRE PROTECTION COMPONENT

21 50 00.HS HORIZONTAL SIDEWALL SPRINKLER

22 40 00.LV LAVATORY

22 40 00.P PLUMBING COMPONENT

22 40 00.WC WATER CLOSET

23 37 13.DF HVAC DIFFUSER

23 80 00.D DUCTWORK

26 10 00.ED ELECTRICAL DEVICE

26 50 00.LF LIGHTING FIXTURE

08 14 33.HR HISTORIC REPLACEMENT WOOD DOORS

08 31 00.AP ACCESS PANEL

08 71 00 DOOR HARDWARE

08 80 00.S3 SINGLE SAFETY GLAZING

09 21 00.PR PLASTER REPAIR

09 21 16.AI ACOUSTIC INSULATION

09 21 16.CL GYPSUM WALLBOARD-CEILING

09 21 16.CM COVE MOULDING

09 21 16.GA GYPSUM BOARD ASSEMBLY

09 21 16.MC METAL CEILING FRAMING

09 21 16.MS METAL STUD WALL FRAMING

09 21 16.SM GYPSUM STEP MOULDING

09 30 00.T3 WALL TILE

09 30 00.T4 BACKSPLASH TILE

09 51 00.ACT ACOUSTICAL CEILING TILE A

09 64 29.WF CHESTNUT WOOD FLOOR

06 20 00.LT LIGHT TROUGH

06 20 00.M MIRROR

06 20 00.PR WOOD PICTURE RAIL

06 20 00.WB WOOD BASE

06 20 00.WDF WOOD DOOR FRAME

06 20 00.WS WOOD WAINSCOT

06 20 00.WW WOOD INTERIOR WINDOW

06 41 00 ARCHITECTURAL WOOD CASEWORK

06 41 00.G GROMMET

06 41 00.POT PULL OUT TRASH

06 41 00.SAS ADJUSTABLE SHELF SUPPORTS

06 41 00.SB SUPPORT BRACKET

06 41 00.SS SOLID SURFACING COUNTERTOP

06 41 00.WC WOOD COUNTERTOP

06 41 00.WOC WOOD CABINETS

07 90 05.S SEALANT

01 60 00.OD OSCI DISHWASHER

01 60 00.OM OSCI MICROWAVE

01 60 00.OR OSCI REFRIGERATOR

01 60 00.OSC OSOI SECURITY DEVICE

01 73 20.SD SELECTIVE DEMOLITION

01 73 20.TA 9x9 ASBESTOS TILE ABATEMENT

04 43 01.MS MARBLE STONE TRIM AND

REFURBISHMENT

05 91 00.CW HISTORIC TREAMENT OF ORNAMENTAL

METALS

06 10 00.B BLOCKING

06 20 00.CM WOOD CROWN MOLDING

06 20 00.CR WOOD CHAIR RAILS

06 20 00.DC WOOD DOOR CASINGS

06 20 00.HP1 PLYWOOD TYPE 1

06 20 00.HW1 HARDWOOD LUMBER 1

4 82 16

Renovated Area:

3175 sf

Occupant Load: (LSC 7.3.1.2) Business: 100 gross sf/person Storage: NA

Fifth Floor:

Business = 32 people

Egress Capacity: (LSC 7.3.3) Stairs: 0.3" / person

Level components and ramps: 0.2"/per Maximum Travel Distance: (LSC 7.6.1)

Business: 300 ft Storage: NA

Maximum Dead End Limit: (LSC 7.6.1) Business: 50 ft Storage: NA

Maximum Common Path of Travel: (LSC 7.6.1) Business: 100 ft Storage: NA

Building Component Ratings:

Structural Frame: 0 hrs Bearing Walls: 0 hrs Nonbearing walls: 0 Floor Construction: 0 hrs Roof Construction: 0 hr

Rated Separations:

Shaft enclosure: 2 hr

Corridors: 2 hr Interior Finish Limitations:

Class A or B in all spaces, except Exits Class A in Exits

APPLICABLE CODES & STANDARDS

- International Building Code, 2018 Edition

- National Fire Protection Association (NFPA) 101 Life Safety Code (LSC), Latest Edition

- Facilities Standards for the Public Building Service- PBS-P100, 2018 Edition.

- Architectural Barriers Act Accessibility Standard (ABAAS), Latest Edition.

- US Courts Design Guide, Latest Edition.

1. The Contractor shall supervise and direct the work, using the Contractor’s best skill and attention.

The Contractor shall be solely responsible for, and have control over, construction means, methods, techniques, sequences, and procedures and for coordinating all portions of the Work. If the Contract Documents give specific instructions concerning construction means, methods, techniques, sequences, or procedures, the Contractor shall evaluate the jobsite safety thereof, and shall be fully responsible for the jobsite safety associated with such instructions. If the Contractor determines that such instructions may not be safe, the Contractor shall give timely written notice to the Owner and Architect and shall not proceed with that portion of the Work without further written instructions from the Architect.

2. The Contractor shall employ a competent superintendent and necessary assistants who shall be in attendance at the Project site during performance of the Work. The superintendent shall represent the Contractor and communications given the superintendent shall be binding as if given to the Contractor.

3. Demolition debris shall be removed from the site daily. Contractor shall clean jobsite daily, maintain a clean workplace and keep construction debris and dust away from adjacent building occupants.

4. Install blocking in all walls indicated to receive wall mounted devices and/ or cabinetry.

5. All wood blocking shall be fire retardant treated.

6. Provide double studs at all openings in walls.

7. Not used.

8. All vertical rated mechanical chase assemblies shall extend from floor finish to structure above.

10. All exposed electrical, fire protection, and mechanical devices shall be centered on or align with architectural features as shown on the Reflected Ceiling Plans.

11. Openings created in slabs, smoke partitions, or fire rated partitions by this work shall be repaired using techniques and materials to maintain the rating of the wall, including but not limited to, smoke dampers, fire dampers, firestopping, and fire safing, penetrations of masonry walls and concrete floors shall be stopped to minimum 2 hour rating.

12. Contractor is to coordinate with Owner provided materials & services, including: Security equipment.

13. All dimensions are to face of finished surfaces, unless noted otherwise.

14. Relocate existing Fire Sprinkler mains, branches, and heads to accomodate specified ceiling heights, ceiling configuration, and lighting layout.

G002 1/8" = 1'-0" 2 Second Floor- Life Safety Plan

MAX COMMON PATH OF

TRAVEL: 100'-0"

ACTUAL COMMON PATH OF

TRAVEL: 95'-0"

DOOR CAPACITY: 180 PPL

DOOR LOAD: 32 PPL

Revision Number

Revision Date Revision Description

ST

ATE OF GEORGI A

REGI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

NORTH

4" V

2" HW

3" CW

4" S

3" EX STANDPIPE

3" V

5" V

2" S

DEMOLISH 2" S DEMOLISH 4" V

4" S ABOVE

4" V 2" S

Floor Drain

2" S

2" S

4" S Active

2" Wet Vent

TOILET

ABOVE

Demo Telephone Closet

EXISTING ELECTRICAL

PANEL

Law CLerk - 139sf Judge's Chambers - 468sf Judicial Assistant - 260sf

Law Clerk - 158sf

Judge's Toilet 26sf

Staff Attorney - 140sf

Closet - 29sf

Breakroom - 124sf Workroom - 91sf Law Clerk - 150sf Law Clerk - 118sf

Vestibule - 243sf

Hallway - 58sf

Library - 374sf

Staff Toilet 27sf

Staff Toilet 32sf

Closet 14sf

Closet 8sf

Closet 8sf

Closet 11sf

Closet - 13sf

Hallway - 400sf

Mechanical - 212sf

Replace Door, Keep Frame

REMOVE

BOOKSHELVES

NOTE 4 NOTE 5

REMOVE AND

SALVAGE FOR

REUSE EXISTING

MARBLE TRIM /

WALL PANELS

1 1

9 9888 8 8 8 8

10 10 10

COORDINATE WALL

DEMOLITION WITH

NEW WALL

INSTALLATION

04 43 01.MS

04 43 01.MS

11 11

Mosaic Tile

Presumed Asbestos Containing Tile Under Existing Finish

Marble Under Existing Finish

Unkown Underlayment

FILL PATTERN LEGEND

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt

3/18/2021 1:15:25 AM

AD100

01/29/21 Consolidated Set

Second Floor Demolition Plan

GB

GW

GS-04-P-15-BV-D-7018

GS-04P-13-BV-D-0009/47PE0218F0142

56 Forsyth Street Atlanta, Georgia

GA00088ZZ

N1696691 Brandy Nabors

Resident Judge’s Chambers on 2

Interior renovation of Court of Appeals Judge's Chambers on second floor

2 41 8

1. Remove existing carpet/wood flooring, padding, plywood underlayment, and abate 9x9 asbestos tile/mastic if present. Remove original hardwood floor back to existing concrete slab. Original wood sleepers embedded in slab to remain. Remove wall covering, ACT ceiling, lighting, all abandoned piping and all abandoned conduit, as exists.

2. Remove existing carpet, padding and other layers to expose existing marble underlayment. In areas to receive new carpet, investigate suitability of marble as carpet underlayment. Review findings with Architect and Owner while uncovered. Remove unsuitable marble as directed. Bid to include removal of up to 200sf of area of marble flooring. Remove ACT ceiling, lighting, all abandoned piping and all abandoned conduit, as exists.

3. Existing Electrical Panel to be relocated, refer to Electrical drawings for details.

4. Protect existing door to remain during construction. Remove card reader and intercom.

5. Existing electrical conduit, data and security equipment to remain. Protect equipment from dust and debris, in coordination with the Tenants IT department representative.

6. Existing drawings/prior renovations indicate wall at area shown may be composed of 2 masonry walls with an opening through floor between. Walls not believed to be structural. Contractor to perform only investigative demolition and coordinate with Owner, building managers and architect prior to undertaking demolition in this area. Demolish all existing vertical chase ducts.

7. Remove existing fixture, see Plumbing Drawings.

8. Remove existing wall base trim, chair rail, crown moulding, window trim, sills and door casings, unless otherwise noted.

9. Remove existing base cabinets, countertop and wall cabinets in the existing workroom and breakroom.

10. Existing Floor boxes in ceiling from 3rd Floor Chambers to remain. Reroute conduit to achieve new ceiling design intent.

11. Existing window trim, sills to remain.

12. Verify transfer air requirements described in note 11 / M200 are met. If minimum required free area is not available, review findings with Architect. Cut masonry openings above ceiling up to the structure, as directed.

04 43 01.MS MARBLE STONE TRIM AND REFURBISHMENT

A. Relocate existing Fire Sprinkler mains, branches, and heads to accomodate specified ceiling heights, ceiling configuration, and lighting layout.

B. Contractor to seal, caulk, and in-fill any existing and new penetrations or openings at all walls located within the scope of work area as required for completely acoustically sealed condition both sides, typ.

C. Contractor is responsible for rerouting any existing conduits, wiring, plumbing and piping as required to achieve the desired layout and design intent shown. New rerouting locations shall be concealed within wall. When it is impossible to conceal items, locate items tight against walls-enclose items with gypsum wall board without disruption of service to other areas.

D. At all exterior walls or where existing perpendicular walls or trim are removed, scrape plaster only to the extent needed to stabilize for reskim-coating plaster finish or furring as required by new construction.

E. Existing Ballistic Window Panels shall be removed, tagged for location, and salvaged for reinstallation. Existing window trim, jamb, sill and aprons to be removed at all windows.

A. Remove and abate asbestos containing 9x9 tile and mastic, where present, below the existing carpet and padding. It is estimated that approximately 2200 square feet of tile are present but the exact quantity is unknown. Report of Limited Pre-Renovation Asbetos Containing Material and Lead Based Paint Sampling for Tuttle Second Floor Renovations, Nova Project No.3018010 09/24/18 is available as Appendix to these Contract Documents.

B. Hazardous material samplying has identified lead based paint on the existing plaster walls and plaster ceilings. Scheduled removal of walls should be done in accordance with OSHA 1926.62 regulations governing lead-safe practices. Lead based paint in ceilings and existing to remain walls shall be abated via encapsulating paint. The contractor shall prepare for encapsulation by removing loose and flaking paint by wet scraping. Refer to 09 9020.

C. For LBP abatement, the means and methods for worker protection and monitoring, are the sole responsibility of the contractor. The contractor shall comply with current OSHA 1926.62 lead regulations for lead safety related to occuapational hazards.

D. Abate all existing piping within scope of work wrapped in asbestos containing materials, known as Thermal System Insulation (TSI).

ABATEMENT NOTES

AD100 1/4" = 1'-0"

1 Second Floor- Demolition

SHEET SPECIFIC NOTES

MATERIAL KEYNOTES

GENERAL NOTES

Revision Number

Revision Date Revision Description

TYPE SR

HISTORIC

REPLACEMENT STILE &

RAIL DOOR

TRIM/ MOLDING

PROFILE TO MATCH

HISTORIC DOORS

DOOR HARDWARE,

SEE 08 7100

TYPE SRG

HISTORIC REPLACEMENT

STILE & RAIL GLASS

DOOR

GLUE CHIP GLAZING

PROFILE TO

MATCH HISTORIC

DOORS

DOOR HARDWARE,

SEE 08 7100

PROFILE TO

MATCH HISTORIC

DOORS

PROFILE TO

MATCH HISTORIC

DOORS

RAISED PANEL TO

MATCH HISTORIC

DOORS

STILE AND RAIL DOOR08 14 33

WOOD DOOR FRAME06 20 00

COLD-FORMED METAL FRAMING05 40 00

Box Beam Header

GYPSUM BOARD ASSEMBLIES09 21 16

Typ. Ea. Side

BLANKET INSULATION07 21 00

COLD-FORMED METAL FRAMING05 40 00

3 5/8" Mtl. Stud Wall

TYPICAL HEAD / JAMB DETAIL @ WOOD FRAME

TYPE

PER WALL

WOOD BLOCKING06 10 00

WOOD DOOR CASING06 46 00

See Door Schedule for Casing Type

TYPE CW

Historic Refinished Copper Exterior Window. Window to receive new trim, jamb, sill and apron. Refer to AI001 for profiles and finish.

TYPE W

Wood Window, See typical Interior Jamb, Head, and Sill details this sheet. Refer to Schedule for Casing Type.

08 80 00.S3

TYPE CWT

Same as CW. Existing window trim, sills, jamb, apron to remain.

BLANK

RA

TI

N G

(IF

A N

Y)

M

S

F

H

D i

BLANK

TY

PE

O F

W A

LL

SI

ZE

O

F U

IT

(M

A

SO

RY

O

R

ST

U D

SP

EC

IA

L

NO SPECIAL PROPERTIES

ACCOUSTIC

8" STUD OR 8" BLOCK

6" STUD OR 6" BLOCK

3-5/8" STUD

2-1/2" STUD

7/8" HAT CHANNEL

DOUBLE STUD

SHAFT

FURRING

STUD

MASONRY

3 HOUR

2 HOUR

1 HOUR

NO RATING

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

GENERAL NOTES

SHEET SPECIFIC NOTES

MATERIAL KEYNOTES

C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt

3/18/2021 1:13:10 AM

A020

01/29/21 Consolidated Set

Partition, Door, Window Types and Schedules gb

GW

GS-04-P-15-BV-D-7018

GS-04P-13-BV-D-0009/47PE0218F0142

56 Forsyth Street Atlanta, Georgia

GA00088ZZ

N1696691 Brandy Nabors

Resident Judge’s Chambers on 2

Interior renovation of Court of Appeals Judge's Chambers on second floor

Door Number Type

Door Frame Casing Type

Fire Rating Hardware Set Access

Control CommentsWidth Height Material Material 270 SR 3' - 0" 7' - 6" Existing Existing Existing HW-1 271 SR 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-9 Yes 272 SR 3' - 0" 6' - 8" 08 1433.HR Existing Existing HW-2 Field Verify existing frame size to accomodate new door.

275 SRG 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-8

276 SRG 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-8

277 SRG 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-8

278 SRG 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-8

279 SRG 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-7

280 SR 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-6 Acoustic Rating STC 55.

281 SR 3' - 0" 7' - 6" Existing Existing Existing HW-3 Existing 283 SR 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-4 Acoustic Rating STC 55.

284 SR 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-4 Acoustic Rating STC 55.

285 SR 3' - 0" 7' - 6" 08 1433.HR 06 20 00.WDF DC HW-5 Acoustic Rating STC 55.

Door Schedule:

Door Types:

A. Hardware shown on door types are for location purposes. See specifications for required hardware.

B. See Door Schedule for material of door types.

C. See Finish Schedule for finish of door frames.

D. See AI002 for Door Casing / Frame Types. For Casing Profiles, refer to AI001 and AI001 for finish.

F. CW and CWT Windows to receive salvaged ballistic windows and new Wood Shutters, per Section 12 2400 and AI002. All other windows to receive wood blinds, per Section 12 2400.

Typical Door Details:

Type Mark Window Material Height Width Finish Glazing

CommentsType CW Refurbished to match building standard copper. Manufacture and install window shutter

Existing Strip existing paint and reburbish historic copper on inter ior side to match building standard on 3rd floor chambers.

CWT 05 91 00.CW 7' - 11" 4' - 5" Refurbished to match building standard copper. Manufacture and install window shutter

Existing Strip existing paint and reburbish historic copper on inter ior side to match building standard on 3rd floor chambers.

EX Existing 5' - 4" 4' - 5" Paint PT-6 Existing W1 06 20 00.WW 3' - 11" 4' - 6" Paint PT-6 Type 1 Float, per 08 8000 Fixed Picture Window, Window Casing Trim 1x3 Hardwood W21 06 20 00.WW 7' - 0" 3' - 0" Paint PT-6 Type 1 Float, per 08 8000 Hinged Picture Windows, Window Casing Trim, See WC-1 AI002

Window Schedule:

08 14 33.HR HISTORIC REPLACEMENT

WOOD DOORS

08 31 00.AP ACCESS PANEL

08 71 00 DOOR HARDWARE

08 80 00.S3 SINGLE SAFETY GLAZING

Window Types

Partition Schedule:

Type Mark Width Graphic Rating UL# Description Comments

EX

F1 1 1/2" Interior: 7/8" 20 gauge metal hat channel @ 16" o.c. w/ 1 layer of

5/8" gypsum board. See Wall Finish Schedule for finish material.

F1.5 2 1/8" Interior: 1 1/2" 20 gauge metal stud @ 16" o.c. w/ 1 layer of 5/8" gypsum board. See Wall Finish Schedule for finish material.

F2 3 1/8" Interior: 2 1/2" 20 gauge metal stud @ 16" o.c. w/ 1 layer of 5/8" gypsum board. See Wall Finish Schedule for finish material

S3 4 7/8" Interior: 3 5/8" 20 gauge metal stud @ 16" o.c. fill cavity 3" S.A.B, w/ 1 layer of 5/8" gypsum board on EACH side. See Wall Finish Schedule for finish material.

S3i 6 1/8" Interior: 3 5/8" 20 gauge metal stud @ 16" o.c. fill cavity 3" S.A.B, w/ 2 layers of 5/8" gypsum board on EACH side. Wall shall extend up to underside of existing slab above, where not required to provide opening for return air per M200. STC 35 rated acoustic insulation.

See Wall Finish Schedule for finish material.

Varies Varies

Wall Type Legend:

Interior Window Jamb

Interior Window Head / Sill

Revision Number

Revision Date Revision Description

ST

ATE OF GEORGI A

REGI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

03/26/19

PROVIDE

CASING AS

SCHEDULED IN

WINDOW

SCHEDULE

PROVIDE CASING AS

SCHEDULED IN

WINDOW SCHEDULE

F.E.C.

CALLED

NORTH

A702

G2

A702

F7

A703

G7

A701G7

A700

A7

A700

A2

A703

J2

A704F7

A700 K5

A700G5

A4

G4

A1

A7

M7

A7

M7

A4

K4

A2

G2

A7

A704 F4

A4 A704 A2

Judge

Judicial Assistant

Breakroom 281 Workroom

Law Clerk 276 Law Clerk

Law Clerk

Mechanical

Judge Toilet

Toilet

Library

Law Clerk 275 Staff Attorney

REF

D W

12' - 3" F.V. 14' - 10" 12' - 6" 20' - 6"

15' - 7" F.V.11' - 6"

Intern

6'

3"

11' - 6" F.V. 11' - 7" F.V.11' - 7"

Stair

AREA NOT IN

SCOPE

A4

EX

CWTCWCW

CWT

CWT

CW

W1 W1 W1W1

CW

W21W21

A300 A7

A300 A1

C.O.

3' - 0"

C.O.

3' - 0"

C .O

3'

0"

6' - 3" 3' - 6"

8'

9"A2

C.O.

3' - 0"

S3

S3

S3i

S3i

S3i

S3i

S3i

S3i

S3i

S3

S3

S3

S3

S3

S3

S3

S3

S3i

S3i

EX

EX

S3

F1.5

8'

3"

A702G4

4' - 7" 7' - 1 5/8"

2' - 0". 4' - 6" 1' - 6" 3' - 0" 1' - 6" 3' - 0" 2' - 0" 4' - 6" 3' - 9 7/8" 4' - 6" 2' - 0" 3' - 0" 1' - 6" 3' - 0" 2' - 0" 4' - 6" 3' - 8" 3' - 0" 1' - 6"

12' - 1" F.V.

2' - 9" A702

G5

A511 F2

A700

A5

K2

F2

A704F4

SI

M

A4SIM.

A704 F7

SI

M

A7SIM.

A7

A500

EX EX EX

A6

A501

35° 35

3' - 4 1/2" 3' - 4 1/2"

01 60 00.OR

01 60 00.OD

8' - 8" 1' - 0"

04 43 01.MS

04 43 01.MS

04 43 01.MS

04 43 01.MS

04 43 01.MS

5'

8"

NOTE 1

A501

E6

A501 E6

F2

F2

8"

8"

F2

F1

NOTE 1 A511K2

A511 F2

SI

M

A511F2

SI

M

A511K2

SI

M

A511 K2

SI

M

EQ EQ

6'

0"

A702

N2

A702 G4

SI

M

10 44 00.2AS

A6

A501

NOTE 2NOTE 2

8' - 10"

3'

9" 2' - 8"

4' - 0"

CDZ

CDZ

CDZ

BC

BC

CWR

CWJ

CWJ

CWJ

VJS

CBR

CBR

12 24 00.WB

12 24 00.WB

12 24 00.WB

12 24 00.WB

12 24 00.WB 12 24 00.WB 12 24 00.WB

.BC

.BC

BC

BC

Outer Vestibule

Inner Vestibule

S3i

F1

F1

S3

F1 F1

F1

F1

F1F1F1

F1 F1.5

2' - 2"

F1 F1.5

NOTE 3, TYP.

NOTE 3, TYP.

09 21 00.PR

AT REMOVED

DEVICES

04 43 01.MS

F1

09 21 00.PR09 21 00.PR

.P R

F2

F2

CBR

IC

CR

IC RR

IC

RR

CR (EXIST)

ALIGN

NOTE 4

12 24 00.WS2

12 24 00.WS2

12 24 00.WS2

12 24 00.WS212 24 00.WS212 24 00.WS212 24 00.WS2

NOTE 5

NOTE 5

A703

SECURITY SYMBOL LEGEND

IC

RR

CR CARD READER

DOOR LOCK REMOTE RELEASE BUTTON

INTERCOM TERMINAL

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES

C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt

3/18/2021 1:13:14 AM

A100

01/29/21 Consolidated Set

Second Floor New Plan

GB

GW

GS-04-P-15-BV-D-7018

GS-04P-13-BV-D-0009/47PE0218F0142

56 Forsyth Street Atlanta, Georgia

GA00088ZZ

N1696691 Brandy Nabors

Resident Judge’s Chambers on 2

Interior renovation of Court of Appeals Judge's Chambers on second floor

01 60 00.OD OSCI DISHWASHER

01 60 00.OR OSCI REFRIGERATOR

04 43 01.MS MARBLE STONE TRIM AND REFURBISHMENT

09 21 00.PR PLASTER REPAIR

10 44 00.2AS 2A FIRE EXT AND SEMI RECESSED CABINET

12 24 00.WB WINDOW BLINDS

12 24 00.WS2 WINDOW SHUTTERS

2 41 8

A. COORDINATE LOCATIONS OF GROMMETS FOR CASEWORK WITH OWNER'S REPRESENTATIVE.

B. REINSTALL EXISTING BALLISTIC WINDOWS IN ORIGINAL WINDOW OPENINGS. COORDINATE NEW WINDOW TRIM AND CASING WITH EXISTING

BALLISTIC WINDOW SIZES.

A100 1/4" = 1'-0" A2 Second Floor- New

Revision Number

Revision Date Revision Description

1. USE SALVAGED MARBLE PANELS AND TRIM FOR NEW MARBLE HEADER AND CASING. CUT SALVAGED

MARBLE AS NECESSARY TO ACHIEVE DESIGN INTENT.

2. SHARED WINDOWS TO BE HINGED PICTURE WINDOWS. WINDOWS TO RECEIVE 3 HINGES AND

CASEMENT LOCKING HARDWARE AT THE JAMBS.

3. APPROXIMATE EXTENT OF EXISTING CHASE REQUIRING FLOOR INFILL. SEE DEMO PLAN.

4. CENTER FIRE EXTINGUISHER CABINET ON WALL. TOP OF CABINET AT 48". CENTER POWER AND DATA

OUTLETS ON WALL AT 60"

5. VERIFY LOCATION WITH ARCHITECT BEFORE INSTALLING

ST

ATE OF GEORGI A

REGI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

03/26/19

Resident Chambers Casework Types Type Mark Description Finish Keynote Comments

BC Bookcases, Library Island Casework Refer to Casework Schedule 06 4100 CBR Casework Breakroom Refer to Casework Schedule 06 4100 06 41 00.WOC CDZ Credenzas and Wall Shelves Refer to Casework Schedule 06 4100 06 41 00.WOC CWJ Casework Judge Refer to Casework Schedule 06 4100 06 41 00.WOC CWR Casework Workroom Refer to Casework Schedule 06 4100 06 41 00.WOC VJS Vanity Judge and Staff Refer to Casework Schedule 06 4100 06 41 00.WOC

1' - 10"

MARBLE HALF

ROUND WALL

CAP, TYPICAL

2' - 0"

4'

0"06 20 00.M

A7

A512SIM.

K7

A300

ADA NOTE 4

1' - 4" 1' - 4" 1' - 4" 1' - 5"

5" 06 41 00.SS

26 50 00.LF

7'

6"

1' - 5" . 1' - 4"

A7

A512 K4

A512

D7

A512

TRASH

C4

A512

5' - 10"

PAPER

TOWEL

DISPENSER

K7

A300

TYP.

OF FIXTURE AND DEVICE

26 10 00.ED

TYP.

ADA

IN FACE OF

CABINET

8" 8"

06 20 00.M

6'

8"

2' - 0"

4'

0"

22 40 00.WC

10 28 00.TP

06 20 00.M

06 41 00.WOC

26 10 00.ED

06 20 00.CM

K7

A300

06 10 00.B

NOTE 4

22 40 00.WC

4'

0"

06 20 00.CM06 20 00.CM

CW

12 24 00.WS2

MARBLE HALF

ROUND WALL

CAP, TYPICAL

06 20 00.CM

EQEQ

10 28 00.BH

Judge Toilet

NOTE 3

1' - 7"

C O

UN

TE

R

5'

4"

22 40 00.WC

10 28 00.TP

06 20 00.M

26 10 00.ED

26 50 00.LF

04 43 01.MS

26 10 00.ED

26 10 00.ED

NOTE 1

NOTE 1

NOTE 2

Toilet

22 40 00.WC10 28 00.TP

1' - 4"

NOTE 2

ADJACENT FINISH

WHERE PRESENT

3/4"

PANEL MOULDING.

P&P PM-2149

MIRROR SURFACEALIGN

06 20 00.M

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

GENERAL NOTES

SHEET SPECIFIC NOTES

MATERIAL KEYNOTES

C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt

3/18/2021 1:13:27 AM

A300

01/29/21 Consolidated Set

Enlarged Bathroom Plans / Elevations gb

GW

GS-04-P-15-BV-D-7018

GS-04P-13-BV-D-0009/47PE0218F0142

56 Forsyth Street Atlanta, Georgia

GA00088ZZ

N1696691 Brandy Nabors

Resident Judge’s Chambers on 2

Interior renovation of Court of Appeals Judge's Chambers on second floor

1 2 4

04 43 01.MS MARBLE STONE TRIM AND

REFURBISHMENT

06 10 00.B BLOCKING

06 20 00.CM WOOD CROWN MOLDING

06 20 00.M MIRROR

06 41 00.SS SOLID SURFACING COUNTERTOP

06 41 00.WOC WOOD CABINETS

10 28 00.BH BATH DOUBLE HOOK

10 28 00.TP TOILET PAPER HOLDER

12 24 00.WS2 WINDOW SHUTTERS

22 40 00.WC WATER CLOSET

26 10 00.ED ELECTRICAL DEVICE

26 50 00.LF LIGHTING FIXTURE

A300 1/2" = 1'-0" E1 Toilet Elevation East

A300 1/2" = 1'-0" J1 Toilet Elevation South

A300 1/2" = 1'-0" G7 Judge's Toilet Elevation East

A300 1/2" = 1'-0" A4 Judge's Toilet Elevation North

A300 1/2" = 1'-0" E4 Judge's Toilet Elevation West

A300 1/2" = 1'-0" J4 Judge's Toilet Elevation South

A300 1/2" = 1'-0" A7 Judge's Bathroom Plan

A300 1/2" = 1'-0" A1 Enlarged Staff Toilet Plan

1. INSTALL ELECTRICAL RECEPTICLE

WITHIN MILLWORK AT 44" ABOVE

FINISHED FLOOR.

2. REFURBISHED MARBLE OR NEW TILE

TO EXTEND WALL TO WALL AND

BELOW NEW FIXTURES AND

CASEWORK.

3. DIMENSION IS BETWEEN CENTERLINE

OF TOILET AND FACE OF WINDOW

TRIM.

4. BLOCKING FOR FUTURE ADA GRAB

BAR AT 35" AFF

Revision Number

Revision Date Revision Description

ST

ATE OF GEORGI A

RE GI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

03/26/19

A300 3" = 1'-0"

K7 MIRROR FRAME DETAIL

NORTH

RECESSED

LIGHT FIXTURES

HVAC

SUPPLY

DIFFUSER

PENDANT

SPRINKLER

HEAD

ACCESS PANELCASEWORK

SIDEWALL

SPRINKLER

HEAD

HVAC

RETURN

DIFFUSER

PENDANT

LIGHT FIXTURES

SURFACE MOUNTED

LIGHT FIXTURES

EXIT SIGN

A4

A500

Breakroom

Workroom

Judicial Assistant

Judge

Library

Judge Toilet

Toilet

Staff Attorney

Law Clerk

Law Clerk

Law Clerk

Law Clerk

Mechanical

Intern

AREA NOT IN

SCOPE OF WORK

AREA NOT IN SCOPE OF WORK

AREA NOT IN

SCOPE

200c

A300 A7

10' - 3 1/2"

9' - 0"

8' - 6"

8' - 6"

10' - 3 1/2"

10' - 2 1/2" 9' - 8"

9' - 10"

8' - 6"

9' - 2" 9' - 1"

10' - 3 5/8"

10' - 4 1/2"

9' - 0"

9' - 0"

10' - 3 1/2"

9' - 3"

9' - 4"

8' - 6" 10' - 5"

8' - 6"

9' - 8"

8' - 6"

8' - 6"

9' - 6"

8' - 6"

9' - 6"

8' - 6"

9' - 6"

8' - 6"

9' - 0"

10' - 3 1/2"

9' - 8"

9' - 0"

7' - 9" 8' - 6"

9"

1' - 1"

9"

EQ EQ

A7

A500

F7

A500 M7

A500

A2

A500

J2

A500

8' - 6"

5'

3/

8"

6'

0"

EQ

EQ

EQ EQ EQ

A6

A501

9"

10' - 3 1/2"

4' - 0" EQ1EQ1

EQ

EQ

7'

2"

5'

1" 3'

6"

8' - 2" F.V. EQ2 4' - 0". EQ2

06 20 00.CM

04 43 01.MS

5'

0" 5'

0"

06 20 00.LT

06 20 00.LT

2' - 0" 1' - 0" F.V. 1' - 0" 2' - 0"

2'

0" F.

V

2'

0"

1' - 2" 3' - 0" 1' - 2"

2'

0"

5' - 3"

3'

6"

26 50 00.LF

EQ1 EQ1

9' - 8"9' - 8"

06 20 00.CM

06 20 00.CM

9' - 6"

9' - 6"

9' - 11"9' - 11"

8' - 2"

NOTE 1

09 21 16.CL

09 21 16.CL

09 21 16.CL

21 50 00.CH

21 50 00.HS

23 37 13.DF

8'

3"

EQ

EQ

1' - 2" 3' - 11"

12 24 00.WS2

12 24 00.WS2

12 24 00.WS212 24 00.WS212 24 00.WS212 24 00.WS2

12 24 00.WS2

08 31 00.AP

1'

2"

9' - 9"

9' - 11"

8' - 6"

8' - 2"

1'

0" 1' - 0"

8 3/4"

EQ

EQ

2'

6"

9' - 10"9' - 11" 8' - 6"

8' - 6"

EQ EQ

3' - 4" 8" 2' - 8"

3'

4'

1"

4' - 8" 3' - 11"

3' - 0" 2' - 10"

1'

2"

2' - 2"

3' - 0"

2' - 10" 2' - 10"

4'

1" 4'

1"3' - 4"

EQ

EQ

EQ

A

LI

G N

A

LI

G N

A

LI

G N

A

LI

G N

8"

8"

1'

1"

8' - 6"

2' - 8"

1' - 1"

09 21 16.AI

NOTE 2

09 21 16.AI

NOTE 2

OF

OPENING

09 21 16.AI

NOTE 2

2'

4" 2'

4"

2' - 4" 2' - 8"

OF

WINDOW

23 37 13.DF

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES

C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt

3/18/2021 1:13:35 AM

A400

01/29/21 Consolidated Set

Second Floor Ceiling Plan

GB

GW

GS-04-P-15-BV-D-7018

GS-04P-13-BV-D-0009/47PE0218F0142

56 Forsyth Street Atlanta, Georgia

GA00088ZZ

N1696691 Brandy Nabors

Resident Judge’s Chambers on 2

Interior renovation of Court of Appeals Judge's Chambers on second floor

09 21 16.AI ACOUSTIC INSULATION

09 21 16.CL GYPSUM WALLBOARD-CEILING

12 24 00.WS2 WINDOW SHUTTERS

21 50 00.CH CONCEALED SPRINKLER HEAD

21 50 00.HS HORIZONTAL SIDEWALL SPRINKLER

23 37 13.DF HVAC DIFFUSER

26 50 00.LF LIGHTING FIXTURE

04 43 01.MS MARBLE STONE TRIM AND

REFURBISHMENT

06 20 00.CM WOOD CROWN MOLDING

06 20 00.LT LIGHT TROUGH

08 31 00.AP ACCESS PANEL

A. ALL DIMENSIONS ARE TO FACE OF FINISHED SURFACES, UNLESS OTHERWISE NOTED.

B. SURFACES INDICATED TO BE ALIGNED OR INDICATE A CENTERLINE, ARE TO HAVE FINISH SURFACES FLUSH WITH

ONE ANOTHER.

C. COORDINATE ALIGNMENT OF FIRE SPRINKLERS WITH RECESSED LIGHT FIXTURES, AS INDICATED.

D. IT IS THE INTENT OF THE CEILING DESIGN TO MAXIMIZE CEILING HEIGHTS. MEPFP COMPONENTS SHALL BE

INSTALLED AS HIGH AS POSSIBLE TO ACHIVE DESIGN INTENT. IF NOTED CEILING HIEIGHTS CAN BE RAISED, COORDINATE WITH ARCHITECT OR OWNER REPRESENTATIVE.

Ceiling Legend

2 41 8

1. USE SALVAGED MARBLE PANELS AND TRIM FOR NEW HEADER AND CASING. CUT SALVAGED MARBLE AS

NECESSARY TO ACHIEVE DESIGN INTENT.

2. INSTALL ACOUSTIC INSULATION DIRECTLY BELOW AND IN FRONT OF TRANSFER DUCT AND WALL OPENING, INSIDE PLENUM. SEE M200 FOR DUCT AND TRASFER DETAILS.

A400 1/4" = 1'-0" A2 Second Floor RCP - New

Revision Number

Revision Date Revision Description

ST

ATE OF GEORGI A

REGI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

1' - 1 5/8" 5 7/8"1' - 0"1' - 0"

9' - 0"

9' - 7"

9' - 3"

1"

09 21 16.GA 09 21 16.CL

1' - 1"

9' - 0"

06 20 00.LT

1' - 0"

9' - 7"

3/ 8"

8"06 20 00.CM

09 21 16.GA

09 21 16.GA

8 7/8" 1' - 0".

9' - 0"

10' - 2 1/2"

8' - 2"

8' - 6"

1' - 0"

7' - 9"

1/

8"04 43 01.MS04 43 01.MS

5/

8"

9"

04 43 01.MS

04 43 01.MS04 43 01.MS

06 20 00.CM

04 43 01.MS

1' - 1 1/4"

10' - 5"

06 20 00.LT

9 1/8"

3' - 6"

9' - 0"

8' - 6"

9' - 6"06 20 00.CM

09 21 16.GA

06 20 00.WW

3' - 9"

06 20 00.CR

3' - 8 1/2"

23 37 13.DF

26 50 00.LF

1' - 2"

3' - 0" 1' - 2"

12 24 00.WS2

05 91 00.CW

06 20 00.LT09 21 16.CL

1' - 2"

1' - 2" 7 7/8" 8"

21 50 00.FC

09 21 16.MC

09 21 16.GA

06 20 00.LT 09 21 16.CL

9' - 1"

9' - 9"

7/ 8"

23 37 13.DF

NOTE 2

21 50 00.HS

23 37 13.DF

6' - 0"

8' - 6"

9' - 0"

1' - 9"

10' - 3 1/2"

09 21 16.GA

09 21 16.GA

09 21 16.AI

06 20 00.HP1

06 20 00.WDF

06 20 00.CM

23 37 13.DF

2 1/2" 2 5/8"

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES

C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt

3/18/2021 1:13:38 AM

A500

01/29/21 Consolidated Set

Ceiling Details

GB

GW

GS-04-P-15-BV-D-7018

GS-04P-13-BV-D-0009/47PE0218F0142

56 Forsyth Street Atlanta, Georgia

GA00088ZZ

N1696691 Brandy Nabors

Resident Judge’s Chambers on 2

Interior renovation of Court of Appeals Judge's Chambers on second floor

16''3''

09 21 16.AI ACOUSTIC INSULATION

09 21 16.CL GYPSUM WALLBOARD-CEILING

09 21 16.GA GYPSUM BOARD ASSEMBLY

09 21 16.MC METAL CEILING FRAMING

12 24 00.WS2 WINDOW SHUTTERS

21 50 00.FC FIRE PROTECTION COMPONENT

21 50 00.HS HORIZONTAL SIDEWALL SPRINKLER

23 37 13.DF HVAC DIFFUSER

26 50 00.LF LIGHTING FIXTURE

04 43 01.MS MARBLE STONE TRIM AND REFURBISHMENT

05 91 00.CW HISTORIC TREAMENT OF ORNAMENTAL METALS

06 20 00.CM WOOD CROWN MOLDING

06 20 00.CR WOOD CHAIR RAILS

06 20 00.HP1 PLYWOOD TYPE 1

06 20 00.LT LIGHT TROUGH

06 20 00.WDF WOOD DOOR FRAME

06 20 00.WW WOOD INTERIOR WINDOW

1. ELEVATION OF SOFFIT IS A MINIMUM OR 1/2" ABOVE TOP OF EXISITNG WINDOW TRIM, WHICHEVER IS

HIGHER.

2. CENTER DIFFUSER RUN ON WINDOW FRAME.

A500 1 1/2" = 1'-0" M7 Library Ceiling at Judges Door

A500 1 1/2" = 1'-0" F7 Library Ceiling at Column Detail

A500 1 1/2" = 1'-0" A7 Ceiling Transition at Entry Vestibule

A500 1 1/2" = 1'-0" J2 Typical Law Clerk Soffit Detail

A500 1 1/2" = 1'-0" A2 Judge's Ceiling Transition Detail

A500 1 1/2" = 1'-0" A4 Typical Soffit Detail

Revision Number

Revision Date Revision Description

ST

ATE OF GEORGI A

REGI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

W21

06 20 00.WW

09 21 16.CL

06 20 00.WB

06 41 00.WC

09 21 16.GA

09 21 16.CL

WINDOW HINGES

WINDOW HINGES

EX

9' - 6"

2'

6"

1'

0"

1' - 0"1/ 4"

1'

0"

F2

09 21 16.GA

SALVAGED

MARBLE

PANELS

04 43 01.MS

09 21 16.GA

OVERHEAD

MARBLE TRIM,

SEE A7/A500

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES

C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt

3/18/2021 1:13:40 AM

A501

01/29/21 Consolidated Set

Details

Author Approver

GS-04-P-15-BV-D-7018

GS-04P-13-BV-D-0009/47PE0218F0142

56 Forsyth Street Atlanta, Georgia

GA00088ZZ

N1696691 Brandy Nabors

Resident Judge’s Chambers on 2

Interior renovation of Court of Appeals Judge's Chambers on second floor

A501 3/4" = 1'-0" A6 Typ. Clerk Shared Window Detail

Revision Number

Revision Date Revision Description

A501 3" = 1'-0" E6 Typical Marble Jamb Detail

04 43 01.MS MARBLE STONE TRIM AND REFURBISHMENT

06 20 00.WB WOOD BASE

06 20 00.WW WOOD INTERIOR WINDOW

06 41 00.WC WOOD COUNTERTOP

09 21 16.CL GYPSUM WALLBOARD-CEILING

09 21 16.GA GYPSUM BOARD ASSEMBLY

ST

ATE OF GEORGI A

REGI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

2"

1/ 4"

1'

1/

8"

1"

1'

1/

4"

1"

1'

1/

4"

1/ 4"

4"

3'

9"

1' - 1"

06 20 00.HW1

06 41 00.WOC

06 20 00.HW1

3/4"

06 41 00.WOC

06 20 00.HW106 20 00.HW1

2' - 1"

3'

0" 2'

6"

2'

9"

8'

3"

EQ

EQ

2' - 1"

2' - 0"

2'

6" 6'

1/ 4"

06 20 00.HP1

06 20 00.HW1

06 20 00.CM

1/

2"

06 41 00.WC

1' - 0"

1/

4" 1/ 4"

4"3"

06 20 00.CM

06 20 00.HP1

FILE DRAWER

HARDWARE

1/ 4"

1/

4"

1/ 4"

N O

TE

/2

CABINET

LOCK

C

LE

A R, T

YP

1'

1"

06 20 00.HW1

06 20 00.HP1

2' - 1"

1'

6"

06 20 00.WB

1/

2"

1 1/4"

A

LI

G N

W

SI

LL

1'

6"

26 10 00.ED

1'

WOODWORK

BEYOND

EQ

'B

EQ

'B

SE

E

EL

EV

A

TIO

N

SE

E

EL

EV

A

TIO

N

3'

0"

1/

2" 1/

4"

1/

4" 1/

4"

EQ

1/ 4"

EQ

N O

TE

N O

TE

EQ

'A

EQ

'A

1/

2" T

YP

2' - 0"

1' - 1"

8'

/4

HE

IG

HT

A

D

JU

ST

A

BL

E

SH

EL

V

ES

06 20 00.HP1

TY

P

C

LE

A R

1'

3/ 4"

1' - 1 3/8"

06 41 00.SAS

1/ 4"

2' - 0"

1/

2" 1/

4"

1/

4"

SE

E

EL

EV

A

TIO

N

SE

E

EL

EV

A

TIO

N

3'

0"

2'

3/

4"

1/

2"

TY

P.4" 1'

1/ 2"

1/ 4"

1'

3/

8"

1/ 4"

1/ 4"

2" N

O

TE

N

O

TE

1"

1 1/4"

3'

8"

06 41 00.SS

06 20 00.HP1

SPACE FOR

OWNER PROVIDED

PAPER SHREDDER

26 10 00.ED

3' - 6"

1"

1 1/4"

4"

EQ

S H

EL

V

ES

2'

3/

4"

1/ 4"

2"

3'

8"

1' - 1" 06 20 00.HW1

06 20 00.HW1

06 41 00.WOC

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

GENERAL NOTES

SHEET SPECIFIC NOTES

MATERIAL KEYNOTES

C:\Users\HWA17\Documents\1830_Tuttle 2nd Floor_Revit20_octavian@houserwalker.com.rvt

3/18/2021 1:13:41 AM

A510

01/29/21 Consolidated Set

Millwork Details

Author Approver

GS-04-P-15-BV-D-7018

GS-04P-13-BV-D-0009/47PE0218F0142

56 Forsyth Street Atlanta, Georgia

GA00088ZZ

N1696691 Brandy Nabors

Resident Judge’s Chambers on 2

Interior renovation of Court of Appeals Judge's Chambers on second floor

A510 1" = 1'-0" C5 Half Bookcase, Library

A510 1" = 1'-0" E5 Workroom Desk, Typical

A510 1" = 1'-0" G5 Judge Hutch at Door Cabient

A510 1" = 1'-0" J5 Judge Hutch at Drawers

A510 1" = 1'-0" C8 Extended Sill Detail

A510 1" = 1'-0" E1 Workroom Base…

This is the start of the file's text. The full file is on GovTribe.