SOW OPTION 2 Resident Chambers 450 and Non Resident Chambers 442 CD DWGS 2021 03 17 (2).pdf
PDF 9 MB Posted
- Solicitation number
- 47PE0221R0011
About this file
This solicitation is for general construction services for the renovation of resident and non-resident judges' chambers at the Elbert P. Tuttle Federal Building in Atlanta, Georgia. The General Services Administration intends to award a firm-fixed-price contract using the lowest price technically acceptable selection process. Renovations are required for two resident judge chambers and four non-resident judge chambers to accommodate the needs of the Court of Appeals. The contract is set aside for small businesses only. The estimated price range for construction services is between $1 million and $5 million. The solicitation will include technical and price proposals that will be evaluated separately, with award going to a single offeror to provide all required construction and renovation work.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
KEY PLAN
CALLED
NORTH
Room name
1i
1t
A101
SIM
ROOM INDICATOR
SLOPE INDICATOR
DETAIL INDICATOR
KP
CR
SECURITY KEYPAD
SECURITY CAMERA
CARD READER ACCESS
TO BE REMOVED (DEMO SHEETS)
EXISTING TO REMAIN
NEW
HIDDEN FEATURES LINE
CENTER LINE
2 HOUR RATED WALL
1 HOUR RATED WALL
PATH OF EGRESS
EGRESS DOOR
# OF ROOM OCCUPANTS
ROOM OCCUPANCY TYPE
A #
OCC.
EXIT EXIT SIGN
NORTH INDICATOR
BUILDING SECTION INDICATOR
WALL SECTION INDICATOR
BREAK LINE INDICATOR
WALL TYPE TAG INDICATOR
WINDOW TYPE TAG INDICATOR
2 41 8
GRAPHIC SCALE, 1/8" = 1'-0"
DOOR TAG INDICATOR
ELEVATION INDICATOR
CENTER LINE
M
06 41 00.PL KEYNOTE INDICATOR
(SEE PROJECT MANUAL)
0 GRID LINE
A101
SIM
INTERIOR ELEVATION INDICATOR
A101 EXTERIOR ELEVATION INDICATOR
CALLOUT INDICATOR
DRAWING TITLE
DIMENSION LINE
FIRE/HORN STROBE
MOTION DETECTOR
1 View Name A101 1/8" = 1'-0"
A101
SIM
A101
SIM
A101
1 Ref
Re f
Re f
1 Ref
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
CIVIL ENGINEER:
MEP ENGINEER:STRUCTURAL ENGINEER:
ARCHITECT:
Occupancy Type:
Construction Type:
Fire Suppression:
Project Name:Image: Project Information:
Project Team:
Drawing List:
C:\Users\HWA17\Documents\1849_Tuttle 4th Floor central_R20_octavian@houserwalker.com.rvt
3/18/2021 1:21:06 AM
G001
01/29/21 100% CD Submission
Cover Sheet gb
GW
Johnson Spellman & Assoc.
350 Research Court Suite 130 Peachtree Corners, GA 30092 678.336.5427
Westside Engineering 5525 Interstate North Parkway- Suite 200 Atlanta, GA 30328 404.965.1287
Houser Walker Architecture 1819 Peachtree Rd NE Suite 102 Atlanta, GA 30309 404.633.4264
Judges' Chambers Renovation on Fourth Elbert P. Tuttle Court of Appeals 56 Forsyth Street NW Atlanta, GA
Existing, Business
Existing 1B (IBC) ; Type II (LSC)
Existing, Sprinklered
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1826380 Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Resident Judge’s Chambers on 4
Interior renovation of Court of Appeals Judge's Chambers on fourth floor
Number Sheet Name 01 /2
9/
C on so lid at ed
S et
C ur re nt
R ev isi on
P PLUMBING
P000 Plumbing Legend, Schedules and Notes O P200 FourthFloor Plumbing Plans O
FP FIRE PROTECTION
FP200 Fourth Floor Fire Protection Plans O
Number Sheet Name 01 /2
9/
C on so lid at ed
S et
C ur re nt
R ev isi on
G GENERAL
G001 Cover Sheet O G002 General Notes, Life Safety & Keynote List O
AD ARCHITECTURAL DEMOLITION
AD100 Architectural Demo Fourth Floor Plan O AD700 Demolition Elevations O
A ARCHITECTURAL
A020 Partition, Door, Window Types and Schedules O A100 Fourth Floor New Resident Chambers O A101 Fourth Floor Plan Non Resident Chambers O A300 Enlarged Bathroom Plans / Elevations O A400 Fourth Floor Resident Ceiling Plan O A401 Fourth Floor Nonresident Ceiling Plan O A500 Details O A501 Details O A510 Millwork Details O A511 Millwork Details O A700 Library Elevations O A701 Resident Judge Elevations O A702 Workroom Elevations O A703 Interior Elevations O A704 Interior Elevations O A705 Breakroom Elevations O A706 Interior Elevations O A707 Interior Elevations O
AI ARCHITECTURAL INTERIORS
AI001 Fourth Floor Finish Schedule and Plan O AI002 Fourth Floor Furniture Referance Plan O
M MECHANICAL
M001 HVAC Legends and Abbreviations O M100 Fourth Floor HVAC Demo Plan O M200 Fourth Floor HVAC New Work Plan O M201 Fourth Floor HVAC New Work Partial Plan South O M400 HVAC Details O M500 HVAC Schedules, Control Sequences and I/O Summary O
ED ELECTRICAL DEMO
ED200 Fourth Floor Demoltiion Plan O
E ELECTRICAL
E001 Notes Details and Legend O E002 Lighting Schedule and Control Panel O E003 Lighting Control Panel Riser O E100 Riser Diagrams O E101 Panel Schedules O E200 Fourth Floor Resident Lighting Plan O E201 Fourth Floor Nonresident Lighting Plan O E300 Fourth Floor Resident Power and Communications Plan O E301 Fourth Floor Nonresident Power and Communications Plan O E400 Fourth Floor Resident Systems Plan O E401 Fourth Floor Nonresident Systems Plan O
Key: O = Current Issued NOT for Construction P = Previously Issued = Not Issued (blank) i = For Information Only
MPFP ENGINEER:ELECTRICAL ENGINEER :
Legend:
Revision Number
Revision Date Revision Description
Consolidated Set RELEASED FOR CONSTRUCTION
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
05/06/19
F.
E.
C
CALLED
NORTH
LAW CLERK
LAW CLERK
LAW CLERK
STAFF
ATTORNEY
ENTRY
WORKROOM
JUDICIAL
ASSISTANT
JUDGE
BREAKROOM
VESTIBULE
STAFF TOILET
TOILET
VESTIBULE
LAW CLERKS
JUDICIAL
ASSISTANT
JUDGE
LAW CLERK
INTERN
JUDGE TOILET
CLOSET
451a
LIBRARY
86'-0" COMMON PATH OF TRAVEL
88'-0" COMMON PATH OF TRAVEL
EXIT
53'-2" COMMON PATH OF TRAVEL
EXIT
MAINTAIN 2-HOUR RATING, TYP
MAINTAIN FIRE
RATING
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
C:\Users\HWA17\Documents\1849_Tuttle 4th Floor central_R20_octavian@houserwalker.com.rvt
3/18/2021 1:21:15 AM
G002
01/29/21 100% CD Submission
General Notes, Life Safety & Keynote List gb
GW
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1826380 Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Resident Judge’s Chambers on 4
Interior renovation of Court of Appeals Judge's Chambers on fourth floor
1. The Contractor shall maintain at the site for the Owner one copy of the Drawings, Specifications, Addenda, Change Orders and other Modifications, in good order and marked currently to indicate field changes and selections made during construction, and one copy of approved Shop Drawings, Product Data, Samples, and similar required submittals.
2. The Contractor shall perform work in accordance with the Contract Documents.
3. The drawings and specifications are complimentary and are to be understood comprehensively. Organization and arrangement of the drawings and/ or specifications into divisions, sections and articles shall not control the Contractor in dividing the work among subcontractors or in establishing the extent of Work to be performed by any trade.
4. Because the Contract Documents are complementary, the Contractor shall, before starting each portion of the Work, carefully study and compare the various Contract Documents relative to that portion of the Work, shall take field measurements of any existing conditions related to that portion of the Work, and shall observe any condition at the site affecting it.
These obligations are for the purpose of facilitating coordination and construction by the Contractor and are not for the purpose of discovering errors, omissions, or inconsistencies in the Contract Documents. However, the Contractor shall promptly report to the Architect any errors, inconsistencies or omissions discovered by or made known to the Contractor as request for information.
5. Drawings are not to be scaled for information.
Contract Documents Existing Conditions
1. Existing adjacent portions of the building are to remain operational throughout construction. Coordinate construction activities and phasing with Architect, GSA COR, and Tenant Representative to minimize disruptions to owner’s operations and access, and to ensure safety of occupants.
2. Attention is called to the fact that this project is a renovation of an existing building. Renovation of existing buildings require thorough coordination of the contract documents with the existing conditions. The Contractor must verify all relevant existing conditions, dimensions, and details prior to beginning construction.
3. All drawings and details incorporating existing conditions are representations of existing conditions only. The Contractor shall verify the accuracy of actual conditions and coordinate with the Architect any deviations of the details so to execute the intent of the drawing or detail.
4. Field Verify existing dimensions prior to ordering or cutting materials.
5. Cutting and Patching: The Contractor shall be responsible for cutting, fitting or patching required to complete the Work or to make parts fit together properly. All areas requiring cutting, fitting and patching shall be restored to the condition existing prior to cutting, fitting and patching.
6. Remove completely materials as indicated on the drawings and as required for new construction. Edges and faces of demolished areas shall be repaired to accept neat installation of new construction or finishes. Where existing materials are to be replaced, existing materials, adhesives, etc. shall be removed and exposed surfaces shall be repaired as recommended by manufacturer prior to installation of new materials.
7. Patch all existing holes and voids and patch holes caused by the removal of equipment, piping, conduit, duct, grills, etc with materials matching existing.
8. Where Finish Schedule shows existing finishes to remain, these finishes to be repaired and/ or extended to be seamless with renovated areas.
9. Surfaces of new and existing finishes are to match in color, texture and consistency, unless noted otherwise.
10. Contractor is responsible for rerouting any existing conduits, wiring, plumbing and piping as required to achieve the desired layout and design intent shown. New rerouting locations shall be concealed within wall. When it is impossible to conceal items, locate items tight against walls- enclose items with gypsum wall board without disruption of service to other areas.
Other General Requirements
General Notes:
Keynote List:
10 44 00.2AS 2A FIRE EXT AND SEMI RECESSED
CABINET
12 22 16.DT DRAPERY & TRACK
12 24 00.WB WINDOW BLINDS
12 24 00.WS2 WINDOW SHUTTERS
21 50 00.CH CONCEALED SPRINKLER HEAD
21 50 00.FC FIRE PROTECTION COMPONENT
21 50 00.HS HORIZONTAL SIDEWALL SPRINKLER
22 40 00.LV LAVATORY
22 40 00.P PLUMBING COMPONENT
22 40 00.WC WATER CLOSET
23 37 13.DF HVAC DIFFUSER
23 80 00.D DUCTWORK
26 10 00.ED ELECTRICAL DEVICE
26 50 00.LF LIGHTING FIXTURE
08 80 00.S3 SINGLE SAFETY GLAZING
09 21 00.PR PLASTER REPAIR
09 21 16.AI ACOUSTIC INSULATION
09 21 16.CL GYPSUM WALLBOARD-CEILING
09 21 16.CM COVE MOULDING
09 21 16.GA GYPSUM BOARD ASSEMBLY
09 21 16.MC METAL CEILING FRAMING
09 21 16.MS METAL STUD WALL FRAMING
09 30 00.T2 FLOOR TILE
09 30 00.T3 WALL TILE
09 30 00.T4 BACKSPLASH TILE
09 51 00.ACT ACOUSTICAL CEILING TILE A
09 64 29.WF CHESTNUT WOOD FLOOR
09 68 13.CPT-1 CARPET
09 90 00.PT6 PAINT COLOR - MILLWORK
10 28 00.M MIRROR
10 28 00.TP TOILET PAPER HOLDER
06 20 00.PR WOOD PICTURE RAIL
06 20 00.REW REFINISH EXISTING WOOD
06 20 00.WB WOOD BASE
06 20 00.WDF WOOD DOOR FRAME
06 20 00.WS WOOD WAINSCOT
06 20 00.WW WOOD INTERIOR WINDOW
06 41 00.CAB WOOD CABINETS
06 41 00.EP END PANEL
06 41 00.POT PULL OUT TRASH
06 41 00.SAS ADJUSTABLE SHELF SUPPORTS
06 41 00.SS SOLID SURFACING COUNTERTOP
06 41 00.WC WOOD COUNTERTOP
06 41 00.WV1
07 84 00.FS FIRESTOPPING
08 14 33.HR HISTORIC REPLACEMENT WOOD DOORS
08 31 00.AP ACCESS PANEL
01 60 00.CO OSOI COPIER
01 60 00.OD OSCI DISHWASHER
01 60 00.OR OSCI REFRIGERATOR
01 70 00.PA PROTECTION OF ADJACENT
CONSTRUCTION
01 73 20.LPA LEAD PAINT ABATEMENT
01 73 20.SD SELECTIVE DEMOLITION
01 73 20.TA 9x9 ASBESTOS TILE ABATEMENT
04 43 01.MS MARBLE STONE TRIM AND
REFURBISHMENT
06 10 00.B BLOCKING
06 20 00.AM ANTIQUED MIRROR
06 20 00.CM WOOD CROWN MOLDING
06 20 00.HP1 PLYWOOD TYPE 1
06 20 00.HW1 HARDWOOD LUMBER 1
06 20 00.LT LIGHT TROUGH
06 20 00.M MIRROR
4 82 16
Renovated Area:
4668 sf
Occupant Load: (LSC 7.3.1.2) Business: 100 gross sf/person Storage: NA
Fourth Floor Resident: 3660 SF Business = 37 people
Fourth Floor Non-Resident: 1008 SF Business = 11 people
Egress Capacity: (LSC 7.3.3) Stairs: 0.3" / person
Level components and ramps: 0.2"/per Maximum Travel Distance: (LSC 7.6.1)
Business: 300 ft Storage: NA
Maximum Dead End Limit: (LSC 7.6.1) Business: 50 ft Storage: NA
Maximum Common Path of Travel: (LSC 7.6.1) Business: 100 ft Storage: NA
Building Component Ratings:
Structural Frame: 0 hrs Bearing Walls: 0 hrs Nonbearing walls: 0 Floor Construction: 0 hrs Roof Construction: 0 hr
Rated Separations:
Shaft enclosure: 2 hr
Corridors: 2 hr Interior Finish Limitations:
Class A or B in all spaces, except Exits Class A in Exits
APPLICABLE CODES & STANDARDS
- International Building Code:
2012 Edition, with Georgia Amendments
- National Fire Protection Association (NFPA) 101 Life Safety Code (LSC):
2018 Edition, with Georgia Amendments, as modified in 120-3-3
- Facilities Standards for the Public Building Service- PBS- P100, 2018 Edition.
- Architectural Barriers Act Accessibility Standard (ABAAS), Latest Edition.
- US Courts Design Guide, Latest Edition.
1. The Contractor shall supervise and direct the work, using the Contractor’s best skill and attention. The Contractor shall be solely responsible for, and have control over, construction means, methods, techniques, sequences, and procedures and for coordinating all portions of the Work. If the Contract Documents give specific instructions concerning construction means, methods, techniques, sequences, or procedures, the Contractor shall evaluate the jobsite safety thereof, and shall be fully responsible for the jobsite safety associated with such instructions. If the Contractor determines that such instructions may not be safe, the Contractor shall give timely written notice to the Owner and Architect and shall not proceed with that portion of the Work without further written instructions from the Architect.
2. The Contractor shall employ a competent superintendent and necessary assistants who shall be in attendance at the Project site during performance of the Work. The superintendent shall represent the Contractor and communications given the superintendent shall be binding as if given to the Contractor.
3. Demolition debris shall be removed from the site daily. Contractor shall clean jobsite daily, maintain a clean workplace and keep construction debris and dust away from adjacent building occupants.
4. Install blocking in all walls indicated to receive wall mounted devices and/ or cabinetry.
5. All wood blocking shall be fire retardant treated.
6. Provide double studs at all openings in walls.
7. Not used.
8. All vertical rated mechanical chase assemblies shall extend from floor finish to structure above.
10. All exposed electrical, fire protection, and mechanical devices shall be centered on or align with architectural features as shown on the Reflected Ceiling Plans.
11. Openings created in slabs, smoke partitions, or fire rated partitions by this work shall be repaired using techniques and materials to maintain the rating of the wall, including but not limited to smoke dampers, fire dampers, firestopping, and fire safing, penetrations of masonry walls and concrete floors shall be stopped to minimum 2 hour rating.
12. Contractor is to coordinate with Owner provided materials & services, including: Security equipment and Breakroom appliances.
13. All dimensions are to face of finished surfaces, unless noted otherwise.
14. Relocate existing Fire Sprinkler mains, branches, and heads to accomodate specified ceiling heights, ceiling configuration, and lighting layout.
G002 1/8" = 1'-0" A1 Fourth Floor- Life Safety Plan
Revision Number
Revision Date Revision Description
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
CALLED
NORTH
4" V
2" HW
3" CW
4" S
AD700
A6
AD700 A2STAIR
1 1
1 1
1 1 1 1 1 1
1 1
6 6 6 6
88887
A5
01 73 20.TA
01 73 20.LPA
01 73 20.LPA
01 73 20.LPA
01 73 20.LPA
04 43 01.MS
01 70 00.PA01 70 00.PA
01 73 20.SD
01 73 20.TA
01 73 20.TA
01 73 20.LPA01 73 20.LPA
01 73 20.LPA
01 73 20.LPA
01 70 00.PA
10 8 10 8 10 8 10 8 10
A511
F6
A511
A7
A511
A5
Mosaic Tile
Presumed Asbestos Containing Tile Under Existing Finish
Marble Under Existing Finish
Unkown Underlayment
FILL PATTERN LEGEND
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
C:\Users\HWA17\Documents\1849_Tuttle 4th Floor central_R20_octavian@houserwalker.com.rvt
3/18/2021 1:20:40 AM
AD100
01/29/21 100% CD Submission
Architectural Demo Fourth Floor Plan gb
GW
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1826380 Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Resident Judge’s Chambers on 4
Interior renovation of Court of Appeals Judge's Chambers on fourth floor
01 70 00.PA PROTECTION OF ADJACENT CONSTRUCTION
01 73 20.LPA LEAD PAINT ABATEMENT
01 73 20.SD SELECTIVE DEMOLITION
01 73 20.TA 9x9 ASBESTOS TILE ABATEMENT
04 43 01.MS MARBLE STONE TRIM AND REFURBISHMENT
AD100 3/16" = 1'-0"
A2 Fourth Floor-Demolition
1. Remove existing carpet/wood flooring, padding, plywood underlayment, and abate 9x9 asbestos tile/mastic if present. See fill pattern legend for pre-renovation presumed extents of tile. Remove original hardwood floor back to existing concrete slab. Original wood sleepers embedded in slab to remain.
Remove wall covering, wood base/chairrail, ACT ceiling, lighting, all abandoned piping and all abandoned conduit, as exists. Report of Limited Pre- Renovation Asbetos Containing Material and Lead Based Paint Sampling for Tuttle Fourth Floor Renovations, Nova Project No. 3018010 12/4/18 is available as Appendix to these Contract Documents.
2. Remove existing carpet, padding and other layers to expose existing marble underlayment. In areas to receive new carpet, investigate suitability of marble as carpet underlayment. Review findings with Architect and Owner while uncovered. Remove unsuitable marble as directed. Bid to include removal of up to 200sf of area of marble flooring. Remove ACT ceiling, lighting, all abandoned piping and all abandoned conduit, as exists.
3. Existing Electrical Panel to be relocated, refer to Electrical drawings for details.
4. Protect existing door to remain during construction.
5. Existing electrical conduit, data and security equipment to remain. Protect equipment from dust and debris, in coordination with the Tenants IT department representative.
6. Existing drawings/prior renovations indicate wall at area shown may be composed of 2 masonry walls with an opening through floor between. Walls not believed to be structural. Contractor to perform only investigative demolition and coordinate with Owner, building managers and architect prior to undertaking demolition in this area. Demolish all existing vertical chase ducts.
7. Remove existing fixtures, see Plumbing Drawings. Remove floor tile, wall tile, toilet accessories, ceilings, lighting, and walls as noted.
8. Remove and salvage existing doors to be refurbished and reinstalled as part of the new work. Protect during construction existing wood casings to remain.
9. Carefully remove existing marble door casings, chairrail, wainscotting, wall base and wall panels, as noted on AD700. Marble to be reinstalled as part of new work.
10. Cut masonry openings above doors up to the structure for mechanical diffusers. Coordinate with Mechanical drawings for rough opening sizes.
A. Relocate existing Fire Sprinkler mains, branches, and heads to accomodate specified ceiling heights, ceiling configuration, and lighting layout.
B. Contractor to seal, caulk, and in-fill any existing and new penetrations or openings at all walls located within the scope of work area as required for completely acoustically sealed condition both sides, typ.
C. Contractor is responsible for rerouting any existing conduits, wiring, plumbing and piping as required to achieve the desired layout and design intent shown. New rerouting locations shall be concealed within wall. When it is impossible to conceal items, locate items tight against walls-enclose items with gypsum wall board without disruption of service to other areas.
D. At all exterior walls or where existing perpendicular walls or trim are removed, scrape plaster only to the extent needed to stabilize for reskim-coating plaster finish or furring as required by new construction.
E. All Window Trim, Jambs and Sills to remain.
A. Remove and abate asbestos containing 9x9 tile and mastic, where present, below the existing carpet and padding. It is estimated that approximately 3300 square feet of tile are present but the exact quantity is unknown.
B. Hazardous material samplying has identified lead based paint on the existing plaster walls and plaster ceilings. Scheduled removal of walls should be done in accordance with OSHA 1926.62 regulations governing lead-safe practices. Lead based paint in ceilings and existing to remain walls shall be abated via encapsulating paint. The contractor shall prepare for encapsulation by removing loose and flaking paint by wet scraping. Refer to 09 9020.
C. For LBP encapsulation abatement, the means and methods for worker protection and monitoring, are the sole responsibility of the contractor.
The contractor shall comply with current OSHA 1926.62 Lead regulations for lead safety related to occuapational hazards.
D. Abate all existing piping within scope of work wrapped in asbestos containing materials, known as Thermal System Insulation (TSI).
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
05/06/19
Revision Number
Revision Date Revision Description
ABATEMENT NOTES
SHEET SPECIFIC NOTES
MATERIAL KEYNOTES
GENERAL NOTES
MARBLE DOOR TRIM QUANTITY TAKEOFF
79" Trim=12 pieces (948") 47" Trim= 6 pieces (282") total=1230" or 102'-0" LINEAR FEET OF MARBLE
SALVAGE EXISTING
MARBLE BASE, TYP
SALVAGE EXISTING
MARBLE WALL
PANEL TYP
SALVAGE EXISTING
MARBLE CHAIRRAIL
TYP
SALVAGE EXISTING
MARBLE DOOR
TRIM, TYP
PROTECT EXISTING MARBLE TRIM,
WAINSCOTTING AND BASE AT ENTRY
SALVAGE EXISTING
MARBLE DOOR
TRIM, TYP
7' - 2 1/2"
SALVAGE EXISTING
MARBLE BASE
SALVAGE EXISTING
MARBLE WALL
PANEL
SALVAGE EXISTING
MARBLE CHAIRRAIL
SALVAGE EXISTING
MARBLE DOOR
TRIM
04 43 01.MS
SALVAGE EXISTING
MARBLE DOOR
TRIM, TYP
PROTECT EXISTING MARBLE TRIM,
WAINSCOTTING AND BASE04 43 01.MS
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES
C:\Users\HWA17\Documents\1849_Tuttle 4th Floor central_R20_octavian@houserwalker.com.rvt
3/18/2021 1:20:42 AM
AD700
01/29/21 100% CD Submission
Demolition Elevations
Author Approver
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1826380 Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Resident Judge’s Chambers on 4
Interior renovation of Court of Appeals Judge's Chambers on fourth floor
AD700 3/8" = 1'-0"
A6 Salvaged Marble North Elevation
AD700 3/8" = 1'-0"
A2 Salvaged Marble West Elevation
Revision Number
Revision Date Revision Description
AD700 3/8" = 1'-0"
A5 Salvaged Marble South Elevation
04 43 01.MS MARBLE STONE TRIM AND REFURBISHMENT
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
TYPE SR
HISTORIC
REPLACEMENT STILE &
RAIL DOOR
TRIM/ MOLDING
PROFILE TO
MATCH HISTORIC
DOORS
DOOR HARDWARE,
SEE 08 7100
TYPE SRG
SALVAGED / REFURBISHED
STILE & RAIL GLASS DOOR
SINGLE SAFETY 'GLUE
CHIP' GLAZING
REFURBISH
EXISTING DOORS,
SEE AI001 FOR
WDF FINISH
DOOR HARDWARE,
SEE 08 7100
STILE, RAIL, &
PROFILE TO MATCH
HISTORIC DOORS
RAISED PANEL TO
MATCH HISTORIC
DOORS
SHOP FINISHED,
SEE AI001 FOR
WDF FINISH
TYPE SR2
HISTORIC
REPLACEMENT STILE &
RAIL PAIR OF DOORS.
TYPE SR NOTES APPLY
STILE AND RAIL DOOR08 14 33
WOOD DOOR FRAME06 20 00
COLD-FORMED METAL FRAMING05 40 00
Box Beam Header
GYPSUM BOARD ASSEMBLIES09 21 16
Typ. Ea. Side
BLANKET INSULATION07 21 00
COLD-FORMED METAL FRAMING05 40 00
3 5/8" Mtl. Stud Wall
TYPICAL HEAD / JAMB DETAIL @ WOOD FRAME
TYPE
PER WALL
WOOD BLOCKING06 10 00
WOOD DOOR CASING06 46 00
See Door Schedule for Casing Type
TYPE CW
Historic Refinished Copper Exterior Window
TYPE WD
Wood Window, See typical Interior Jamb, Head, and Sill details this sheet.
08 80 00.S3
EXISTING TRIM TO REMAIN
REFINISH
HISTORIC
WINDOW
COPPER
PAINT EXISTING
TRIM PT-6
BLANK
RA
TI
N G
(IF
A N
Y)
M
S
F
H
D i
BLANK
TY
PE
O F
W A
LL
SI
ZE
O
F U
IT
(M
A
SO
RY
O
R
ST
U D
SP
EC
IA
L
NO SPECIAL
PROPERTIES
ACCOUSTIC
8" STUD OR 8" BLOCK
6" STUD OR 6" BLOCK
3-5/8" STUD
2-1/2" STUD
7/8" HAT CHANNEL
DOUBLE STUD
SHAFT
FURRING
STUD
MASONRY
3 HOUR
2 HOUR
1 HOUR
NO RATING
M A
TC
H
W A
LL
MATCH WALL
See H2/A500 for Window Casing
See H2/A500 for Window Casing
See H2/A500 for Window Casing
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
MATERIAL KEYNOTES
GENERAL NOTES
SHEET SPECIFIC NOTES
C:\Users\HWA17\Documents\1849_Tuttle 4th Floor central_R20_octavian@houserwalker.com.rvt
3/18/2021 1:19:18 AM
A020
01/29/21 100% CD Submission
Partition, Door, Window Types and Schedules gb
GW
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1826380 Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Resident Judge’s Chambers on 4
Interior renovation of Court of Appeals Judge's Chambers on fourth floor
Door Number Type
Door Frame Casing Type Hardware Set Access
Control Comments Width Height Material Material
442 SR 3' - 0" 7' - 5" Existing Refurbished Existing DC HW-2 Electric Strike Add electric strike per hardware set 442b SR 3' - 0" 7' - 5" 08 1433.HR 06 20 00.WDF DC HW-8 443 SR 3' - 0" 7' - 5" 08 1433.HR 06 20 00.WDF DC HW-4 Acoustic Rating STC 55. 180 Degrees Hinges 445 SR 3' - 0" 7' - 5" 08 1433.HR 06 20 00.WDF DC HW-4 Acoustic Rating STC 55.
446a SR 3' - 0" 7' - 5" 08 1433.HR 06 20 00.WDF DC HW-3 Acoustic Rating STC 55.
446b SR 3' - 0" 7' - 5" 08 1433.HR 06 20 00.WDF DC HW-5 450 SR 3' - 0" 7' - 5" Existing Refurbished Existing DC HW-1 Electric Stike Add electric strike per hardware set
451a SR 3' - 0" 7' - 5" 08 1433.HR 06 20 00.WDF DC HW-3 452a SR 2' - 0" 7' - 5" 08 1433.HR Existing DC HW-7 Field Verify existing door frame for new door.
452b SR2 4' - 0" 7' - 5" 08 1433.HR Existing DC HW-9 Field Verify existing door frame for new pair of doors 453 SRG 3' - 0" 7' - 4" Existing Refurbished 06 20 00.WDF DC HW-8 New Glue Chip Glazing to match historic glazing.
454 SRG 3' - 0" 7' - 4" Existing Refurbished 06 20 00.WDF DC HW-8 New Glue Chip Glazing to match historic glazing.
455 SRG 3' - 0" 7' - 4" Existing Refurbished 06 20 00.WDF DC HW-8 New Glue Chip Glazing to match historic glazing.
456 SRG 3' - 0" 7' - 4" Existing Refurbished 06 20 00.WDF DC HW-8 New Glue Chip Glazing to match historic glazing.
457 SRG 3' - 0" 7' - 4" Existing Refurbished 06 20 00.WDF DC HW-8 New Glue Chip Glazing to match historic glazing.
458 SR 3' - 0" 7' - 5" 08 1433.HR 06 20 00.WDF DC HW-6 Acoustic Rating STC 55.
462 SR 3' - 0" 7' - 5" 08 1433.HR 06 20 00.WDF DC HW-4 Acoustic Rating STC 55. 180 Degrees Hinges
462a SR 3' - 0" 7' - 5" 08 1433.HR 06 20 00.WDF DC HW-3 465 SR 3' - 0" 7' - 5" 08 1433.HR 06 20 00.WDF DC HW-4 Acoustic Rating STC 55.
466 SR 3' - 0" 7' - 5" 08 1433.HR 06 20 00.WDF DC HW-6 Acoustic Rating STC 55.
467 SR 3' - 0" 7' - 5" 08 1433.HR 06 20 00.WDF DC HW-6 Acoustic Rating STC 55.
Door Schedule:
Door Types: A. Hardware shown on door types are for location purposes. See specifications for required hardware.
B. See Door Schedule for material of door types.
C. See Finish Schedule for finish of door frames.
D. See AI002 for Door Casing / Frame Types. For Casing Profiles, refer to AI001 and AI001 for finish.
E. All CW Windows to receive Wood Shutters. All WD Window to receive Wood Blinds.
F. Door Type SRG are to be salvaged existing doors to be refurbished. Salvaged doors are to be selected by architect or Courts Representative. Refurbished doors shall be stripped of all existing door hardware and glazing. Existing holes from removed hardware are to be patched. Door shall be sanded to natural white oak, restained and finished to match casework finish.
See AI001 for wood door finish.
Typical Door Details:
Type Mark Window Material Height Width Finish Glazing
CommentsType CW 5' - 8 1/2" Strip existing paint and reburbish copper to match building standard copper windows
Existing Lacquer finish over refurbished copper.
W1 06 20 00.WW 4' - 11" 2' - 0" Stained to Match Historic Doors Type 1 Float, per 08 8000 Refer to AI001 for WoodFinish W2 06 20 00.WW 4' - 10" 3' - 0" Stained to Match Historic Doors Type 1 Float, per 08 8000 Refer to AI001 for WoodFinish
Window Schedule:
08 14 33.HR HISTORIC REPLACEMENT
WOOD DOORS
08 31 00.AP ACCESS PANEL
08 80 00.S3 SINGLE SAFETY GLAZING
Window Types
Partition Schedule:
Type Mark Width Graphic Rating UL# Description Comments
EX
F1 1 1/2" Interior: 7/8" 20 gauge metal hat channel @ 16" o.c. w/ 1 layer of
5/8" gypsum board. See Wall Finish Schedule for finish material.
F2 3 1/8" Interior: 2 1/2" 20 gauge metal stud @ 16" o.c w/ 1 layer of 5/8" gypsum board. See Wall Finish Schedule for finish material
S3 4 7/8" Interior: 3 5/8" 20 gauge metal stud @ 16" o.c. fill cavity 3" S.A.B, w/ 1 layer of 5/8" gypsum board on EACH side. See Wall Finish Schedule for finish material.
S3i 6 1/8" Interior: 3 5/8" 20 gauge metal stud @ 16" o.c. fill cavity 3" S.A.B, w/ 2 layers of 5/8" gypsum board on EACH side. Wall shall extend up to underside of existing slab above, where not required to provide opening for return air per M200. STC 35 rated acoustic insulation. See Wall Finish Schedule for finish material.
VARIES
Wall Type Legend:
Interior Window Jamb
Interior Window Head / Sill
VARIES
Revision Number
Revision Date Revision Description
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
C
KEY PLAN
CALLED
NORTH
A700
A7
LAW CLERK
LAW CLERK
LAW CLERK
STAFF
ATTORNEY
STAIR
ENTRY
WORKROOM
JUDICIAL
ASSISTANT
JUDGE
BREAKROOM
VESTIBULE
STAFF TOILET
JUDGE
LAW CLERK
7'
3"
12' - 7"15' - 1".15' - 0" F.V. 31' - 6"
CLOSET
451a
JUDGE TOILET
DATA
452b
ELEC
452a
INTERN
1a
REFER TO A101 FOR
NON-RESIDENT CHAMBERS
LIBRARY
A700
A5
A700 A2
A705
G7
A702
G7
A703
H7
A701
A7
A300
A4
A300
H4
A1
A4
A4
A7 A7 A4
A703
F1
A1A704
G7
G4A7
A4
A700
J2
A700
F2
A704
A1
G1
6'
0" F
.V
G1
A4
A300 A7
A300 H7
CLOSET
462a
462a
F4 A7
G4
452b
452a W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W2W2 W2
CW CW CW CW
CW
CW
CW
CWCWCWCWCWCW
15' - 2" 15' - 3".15' - 0" 16' - 6" F.V.
/4
1 1 1 1
A705
K4
A705 G4
9'
6"
10' - 7"
A704
A1SIM.
4' - 3"
8'
7/
8" 3'
6"
J1
A702A1
A702 D1
A702
G1
A702
K1
8' - 0" 2' - 0" 2' - 5" 6' - 0" 6' - 0" 3' - 11" 6' - 0" 6' - 0" 4' - 2" 6' - 0" 6' - 0" 1' - 4" 2' - 0" 3' - 1" F.V.
3'
0"
3'
0"
7'
9"
S3i
S3
S3
S3
S3i
S3i
S3i S3i
S3i
S3iS3i
S3
S3 S3 S3
S3
S3
S3i
S3S3S3S3
CP CP
CDZ
CDZ CDZ
CWR
CWJ
CDZ
LBC
VS
VS
CWJCBR CWR
CWJ
CBR
CWR
CWR
CWR
4' - 6"
6'
2"
4' - 6"
6'
2"
A511 F7
H2
A500
04 43 01.MS04 43 01.MS04 43 01.MS 04 43 01.MS
04 43 01.MS
A705
A1
1'
0"
06 20 00.REW 06 20 00.REW 06 20 00.REW
10 44 00.2AS
12 24 00.WS2
12 24 00.WB
12 24 00.WS2
12 24 00.WS212 24 00.WS2 12 24 00.WS2 12 24 00.WS2
12 24 00.WS212 24 00.WS212 24 00.WS2
12 24 00.WS2
10' - 5". 4' - 10"
CDZ
A511
F6
NOTE 2, TYP.
F2
F2
F2
09 21 00.PR
09 21 00.PR09 21 00.PR
.P R
09 21 00.PR
LBC
A511
A7
A511
A5
12 24 00.WS2
12 24 00.WS212 24 00.WS212 24 00.WS212 24 00.WS212 24 00.WS2
CWJ
SD
SD
7' - 0"
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES
C:\Users\HWA17\Documents\1849_Tuttle 4th Floor central_R20_octavian@houserwalker.com.rvt
3/18/2021 1:19:33 AM
A100
01/29/21 100% CD Submission
Fourth Floor New Resident Chambers gb
GW
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1826380 Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Resident Judge’s Chambers on 4
Interior renovation of Court of Appeals Judge's Chambers on fourth floor
04 43 01.MS MARBLE STONE TRIM AND REFURBISHMENT
06 20 00.REW REFINISH EXISTING WOOD
09 21 00.PR PLASTER REPAIR
10 44 00.2AS 2A FIRE EXT AND SEMI RECESSED CABINET
12 24 00.WB WINDOW BLINDS
12 24 00.WS2 WINDOW SHUTTERS
2 41 8
A. COORDINATE LOCATIONS OF GROMMETS FOR CASEWORK WITH OWNER'S REPRESENTATIVE.
B. REFURBISH MARBLE WALL PANELS AND TRIM TO REMAIN IN ENTRY AND LIBRARY.
1. REFURBISH EXISTING WOOD DOOR CASINGS, SHALL BE STRIPPED OF ALL EXISTING DOOR HARDWARE. EXISTING HOLES FROM REMOVED HARDWARE ARE TO BE PATCHED. DOOR SHALL BE SANDED TO NATURAL WHITE OAK, STAINED AND FINISHED TO MATCH CASEWORK FINISH. SEE AI001 FOR
WOOD DOOR CASING FINISH.
2. APPROXIMATE EXTENT OF EXISTING CHASE REQUIRING FLOOR INFILL. SEE DEMO PLAN
Revision Number
Revision Date Revision Description
Resident Chambers Casework Types Type Mark Description Finish Keynote Comments
CBR Casework Breakroom Refer to Casework Schedule 06 4100 06 41 00.CAB CDZ Credenzas and Wall Shelves Refer to Casework Schedule 06 4100 06 41 00.CAB CP Column Panels Refer to Casework Schedule 06 4100 06 20 00.HP1
CWJ Casework Judge Refer to Casework Schedule 06 4100 06 41 00.CAB CWR Casework Workroom Refer to Casework Schedule 06 4100 06 41 00.CAB LBC Library Bookcase Refer to Casework Schedule 06 4100 06 20 00.HP1 SD Standing Desk Top Refer to Casework Schedule 06 4100 06 41 00.WC 30" X 84" Desk top to be fastened by contractor to owner provided standing desk base.
VS Vanity Judge and Staff Refer to Casework Schedule 06 4100 06 41 00.CAB
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
C
STAIR
TOILET
VESTIBULE
LAW CLERKS
JUDICIAL
ASSISTANT
440 JUDGE
16' - 0" F.V.6' - 0"15' - 8"10' - 4" F.V.
2b
6b
6a
A300 A1
A300 F1
A706 K1
A706
H6
A6
A707
G1
A707
A4
A3
A7
A2
CW CW CW
06 41 00.CAB
NRV
NRW
S3i
S3 S3
S3
S3i
S3 S3
ALIGN
S3i
12 24 00.WS212 24 00.WS212 24 00.WS2
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES
C:\Users\HWA17\Documents\1849_Tuttle 4th Floor central_R20_octavian@houserwalker.com.rvt
3/18/2021 1:19:36 AM
A101
01/29/21 100% CD Submission
Fourth Floor Plan Non Resident Chambers
Author Approver
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1826380 Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Resident Judge’s Chambers on 4
Interior renovation of Court of Appeals Judge's Chambers on fourth floor
A101 1/4" = 1'-0" A2 Fourth Floor- New Non-Resident
Revision Number
Revision Date Revision Description
Non-Resident Chambers Casework Types Type Mark Description Finish Keynote Comments
NRV Non Resident Vanity PT-6 06 41 00.CAB NRW Non Resident Wardrobe PT-6 06 41 00.CAB
06 41 00.CAB WOOD CABINETS
12 24 00.WS2 WINDOW SHUTTERS
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
GFI
GFI GFI
G
FI
1 1/2" 2' - 0" 1' - 10" 1' - 4" 1' - 4" 1' - 10" 1' - 10"
26 50 00.LF
06 41 00.CAB
10 28 00.TP22 40 00.WC
09 30 00.T3
2'
5"
NOTE 3
1' - 6" M1
A511 H1
A511 F1
A511 C1
A511
NOTE 1
06 20 00.M
2' - 6"
4'
0"
06 41 00.SS
ADA
NOTE 4
26 10 00.ED
11"
26 10 00.ED
J1
A300
HERRINGBONE
PATTERN, NOTE 5
09 30 00.T4
09 30 00.T4
HERRINGBONE
PATTERN, NOTE 5
1' - 3" 1' - 4" 1' - 4" 1' - 3"
4'
0"
2' - 6"
06 20 00.M
06 41 00.SS
06 41 00.CAB
26 50 00.LF
22 40 00.WC10 28 00.TP
C1
A511
SIM
F1
A511
SIM
NOTE 1 ADA
NOTE 4
J1
A300
A300 F1
6' - 0"
TOILET
22 40 00.WC
10 28 00.TP
22 40 00.LV
06 41 00.SS7'
1"
1'
7"
NOTE 2
A300
A4
7'
3"
10' - 3" F.V. 4' - 10 1/8"
JUDGE TOILET
22 40 00.WC10 28 00.TP26 50 00.LF26 50 00.LF 10 28 00.M
08 14 33.HR09 30 00.T3
09 30 00.T4
06 41 00.CAB
S3i
S3i
09 30 00.T2
04 43 01.MS
.P R
NOTE 2
A300
H4 STAFF TOILET
6'
3/
8"
1' - 7"
10 28 00.M 26 50 00.LF26 50 00.LF 22 40 00.WC
10 28 00.TP
09 30 00.T3 09 30 00.T2
06 41 00.SS06 41 00.CAB
08 14 33.HR
10' - 7"
NOTE 2
2' - 6"
4'
0"
1' - 4" 1' - 4"
06 41 00.SS
10 28 00.M
06 41 00.CAB
22 40 00.WC
C1
A511
SIM
09 30 00.T3
7' - 1"
ADA
3' - 10"
NOTE 4
ADJACENT FINISH
WHERE PRESENT
3/4"PANEL MOULDING.
P&P PM-2149
MIRROR SURFACE ALIGN
06 20 00.M
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
MATERIAL KEYNOTES
GENERAL NOTES
SHEET SPECIFIC NOTES
C:\Users\HWA17\Documents\1849_Tuttle 4th Floor central_R20_octavian@houserwalker.com.rvt
3/18/2021 1:19:45 AM
A300
01/29/21 100% CD Submission
Enlarged Bathroom Plans / Elevations gb
GW
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1826380 Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Resident Judge’s Chambers on 4
Interior renovation of Court of Appeals Judge's Chambers on fourth floor
1 2 4
04 43 01.MS MARBLE STONE TRIM AND REFURBISHMENT
06 20 00.M MIRROR
06 41 00.CAB WOOD CABINETS
06 41 00.SS SOLID SURFACING COUNTERTOP
08 14 33.HR HISTORIC REPLACEMENT WOOD DOORS
09 21 00.PR PLASTER REPAIR
09 30 00.T2 FLOOR TILE
09 30 00.T3 WALL TILE
09 30 00.T4 BACKSPLASH TILE
10 28 00.M MIRROR
10 28 00.TP TOILET PAPER HOLDER
22 40 00.LV LAVATORY
22 40 00.WC WATER CLOSET
26 10 00.ED ELECTRICAL DEVICE
26 50 00.LF LIGHTING FIXTURE
A300 1/2" = 1'-0" A4 Judge Vestibule North Elevation
A300 1/2" = 1'-0" H4 Staff Toilet Elevation
A300 1/2" = 1'-0" A1 Nonresident Judge Toilet Enlarged Plan
A300 1/2" = 1'-0" A7 Judge Toilet Enlarged Plan
A300 1/2" = 1'-0" H7 Staff Attorney Enlarged Plan
A300 1/2" = 1'-0" F1 Nonresident Toilet East Elevation
Revision Number
Revision Date Revision Description
1. PROVIDE CABINET POWER OUTLET
IN REAR OF CASEWORK DRAWER.
2. REFURBISHED MARBLE OR NEW TILE
TO EXTEND WALL TO WALL AND
BELOW NEW FIXTURES AND
CASEWORK.
3. DIMENSION IS BETWEEN CENTERLINE
OF TOILET AND FACE OF WINDOW
TRIM
4. BLOCKING FOR FUTURE ADA GRAB
BAR AT 35" AFF
5. TO BE INSTALLED IN A
HERRINGBONE PATTERN
THROUGHOUT BACKSPLASH AREA.
PATTERN SHOWN FOR REFERENCE,
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
05/06/19
A300 3" = 1'-0"
J1 MIRROR FRAME DETAIL
GFI GFI
G
FI
KEY PLAN
CALLED
NORTH
RECESSED
LIGHT FIXTURES
HVAC
CONVENTIONAL
SUPPLY DIFFUSER
PENDANT
SPRINKLER
HEAD
ACCESS PANEL
CASEWORK
SIDEWALL
SPRINKLER
HEAD
HVAC
CONVENTIONAL
RETURN DIFFUSER
PENDANT
LIGHT FIXTURES
RECESSED TROFFER
LIGHT FIXTURES
EXIT SIGN
HVAC SLOT
SUPPLY DIFFUSER
HVAC RETURN
SLOT DIFFUSER
A7
A500
E7
A500
LAW CLERK
LAW CLERK
LAW CLERK
STAFF
ATTORNEY
ENTRY
BREAKROOM
WORKROOM
JUDICIAL
ASSISTANT
JUDGE
VESTIBULE
STAFF TOILET
LAW CLERK
INTERN
JUDGE TOILET
CLOSET
451a
9' - 4"
9' - 2 1/2"
10' - 5"
H6
A501
10' - 0"
8' - 6"
8' - 6"
4'
3" 4'
3"
5'
8' - 6"
9' - 9"
9' - 9"
8' - 6" 8' - 6"
9' - 9"
10' - 5"
9' - 2 1/2" 9' - 2 1/2"
8' - 6"
9' - 0"
8' - 6"
8' - 6"
9' - 10"
8' - 6"9' - 10"
8' - 6"
9' - 10"9' - 10"
8' - 6" 8' - 6"
9' - 10"
8' - 6"
10' - 0"
9' - 2"
9' - 2"10' - 0"
8' - 6"
8' - 6" A4
A500
H2
A500
E7
A500
SIM
M7
A500
08 31 00.AP
A6
A501
06 20 00.HP1 06 20 00.LT04 43 01.MS
5'
2' - 0" 2' - 0"
1' - 0" 10' - 0" 1' - 0"
1'
1"
1'
1"
06 20 00.LT 06 20 00.LT
5' - 11"
2'
6"
3'
6"
1/
4"
2' - 2" 2' - 2" 6 1/2"
3/
4"
6"
21 50 00.CH 21 50 00.HS
21 50 00.HS
6'
4" 6'
4"
EQ EQ
OF SOFFIT AND FIXTURES
3' - 0" 3' - 0"
3' - 0" 3' - 0"
OF WINDOW
AND FIXTURES
EQ EQEQ EQ
3' - 0" 3' - 0"
1'
2"
EQ EQ
2' - 0"2' - 0"
1' - 1"
8' - 6"
8' - 6"
8' - 6"
8' - 6"
8' - 6"
1'
2"
1'
0"
OF COLUMNS
AND PENDANTS
EQ
EQ
OF ENTRY 450 ,
FIXTURES AND
SPRINKLER
HEADS
3'
0"
3'
1/
2"OF FIXTURES
AND SPRINKLER
HEADS
EQ
EQ
1'
1'
OF SOFFIT ,
FIXTURES AND
SPRINKLER
HEADS
EQ
EQ
OF FIXTURES
OF FIXTURES
EQ
EQ
OF FIXTURES
AND SPRINKLER
HEADS
EQ
EQ
EQ
EQ
1'
2"
1'
4"
EQ EQ
2'
/2
2'
/2
2'
9"
EQ EQ
EQ
EQ
EQ EQ
1' - 0"
EQ EQ3' - 8 1/2"
2' - 10" 5' - 0"
EQ
EQ
NOTE X,
TYP.
EQ EQ
3' - 6" 3' - 6"
EQ EQ
3' - 8" 3' - 8"
EQ EQ
3' - 8" 3' - 8" 3' - 8" 3' - 8"
3' - 6" 3' - 6"EQ EQ
5' - 0" 5' - 0" 3' - 9" 3' - 9" 3' - 9" 2' - 3"2' - 3"
09 21 16.AI
09 21 16.AI
NOTE 2
NOTE 2
09 21 16.AI
NOTE 2
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES
C:\Users\HWA17\Documents\1849_Tuttle 4th Floor central_R20_octavian@houserwalker.com.rvt
3/18/2021 1:19:52 AM
A400
01/29/21 100% CD Submission
Fourth Floor Resident Ceiling Plan gb
GW
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1826380 Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Resident Judge’s Chambers on 4
Interior renovation of Court of Appeals Judge's Chambers on fourth floor
21 50 00.CH CONCEALED SPRINKLER HEAD
21 50 00.HS HORIZONTAL SIDEWALL SPRINKLER
04 43 01.MS MARBLE STONE TRIM AND REFURBISHMENT
06 20 00.HP1 PLYWOOD TYPE 1
06 20 00.LT LIGHT TROUGH
08 31 00.AP ACCESS PANEL
09 21 16.AI ACOUSTIC INSULATION
A. ALL DIMENSIONS ARE TO FACE OF FINISHED SURFACES, UNLESS OTHERWISE NOTED.
B. SURFACES INDICATED TO BE ALIGNED ARE TO HAVE FINISH SURFACES FLUSH WITH ONE ANOTHER.
C. COORDINATE ALIGNMENT OF FIRE SPRINKLERS WITH RECESSED LIGHT FIXTURES, AS INDICATED.
D. IT IS THE INTENT OF THE CEILING DESIGN TO MAXIMIZE CEILING HEIGHTS. MEPFP COMPONENTS
SHALL BE INSTALLED AS HIGH AS POSSIBLE TO ACHIEVE DESIGN INTENT. IF NOTED CEILING
HEIGHTS CAN BE RAISED, COORDINATE WITH ARCHITECT OR OWNER REPRESENTATIVE.
Ceiling Legend A400 1/4" = 1'-0" A2 Fourth Floor-New Resident
Revision Number
Revision Date Revision Description
ST
ATE OF GEORGI A
REGI S T E RED A RCHI T EC
T
GREGORY WALKER
LICENSE NO. RA010
05/06/19
1. CENTERLINE OF FIXTURES AND DOOR OR WINDOW OPENING.
2. INSTALL ACOUSTIC INSULATION DIRECTLY BELOW AND IN FRONT OF TRANSFER DUCT AND WALL
OPENING, INSIDE PLENUM. SEE M200 FOR DUCT AND TRASFER DETAILS.
STAIR
JUDICIAL
ASSISTANT
LAW CLERKS
TOILET
VESTIBULE
JUDGE
2'
0" 5'
9' - 3"
10' - 0"
8' - 0"
9' - 0"
9' - 8"9' - 8"
8' - 6" 8' - 6"
7' - 6"
07 84 00.FS
26 50 00.LF
06 20 00.CM
09 21 16.CL
09 51 00.ACT 09 51 00.ACT
09 51 00.ACT
4'
3' - 0" 1' - 0"
2'
2'
0"
OF FIXTURES
AND CEILING
INSET
2' - 0"
EQ EQ
OF FIXTURES AND
CEILING INSET
EQ
EQ
3'
5" 3'
5"
4' - 0" 4' - 0"
EQ
EQ
KEY PLAN
CALLED
NORTH
RECESSED
LIGHT FIXTURES
HVAC
CONVENTIONAL
SUPPLY DIFFUSER
PENDANT
SPRINKLER
HEAD
ACCESS PANEL
CASEWORK
SIDEWALL
SPRINKLER
HEAD
HVAC
CONVENTIONAL
RETURN DIFFUSER
PENDANT
LIGHT FIXTURES
RECESSED TROFFER
LIGHT FIXTURES
EXIT SIGN
HVAC SLOT
SUPPLY DIFFUSER
HVAC RETURN
SLOT DIFFUSER
XX0000XX XX0000XX XX0000XX
XX0000XX XX0000XX XX0000XX
XXXX
HOUSER WALKER ARCHITECTURE, LLC.
C
ER
TIF
IC
AT
IO
NS
KE
Y
PL
AN
RE
VI
SIO
N
NO
TE
S
SHEET SIZE:
DISCIPLINE SHEET NUMBER
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
DR
AW
IN
G
PR
O
JE
C
T
BU
ILD
IN
G
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
NT
RA
C
TO
RS
MARK DATE DESCRIPTION
FLOOR NO.
CONSTR. CON.
FACILITY CODE
PROJECT
A/E TASK NO.
CONS. WORK
22 X 34
GENERAL SERVICES ADMINISTRATION
Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303
VALID ONLY FOR 22" x 34" SHEET SIZE.
WRITTEN SCALES AT DRAWING TITLE(S) ARE
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
H O U S E R W A L K E R A R C H I T E C T U R E
1819 PEACHTREE ROAD, NE
SUITE 102
ATLANTA, GA 30309
T. 4 0 4 . 6 3 3 . 4 2 6 4
F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com
A B C D E F G H J K M N P R
GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES
C:\Users\HWA17\Documents\1849_Tuttle 4th Floor central_R20_octavian@houserwalker.com.rvt
3/18/2021 1:19:55 AM
A401
01/29/21 100% CD Submission
Fourth Floor Nonresident Ceiling Plan
Author Approver
56 Forsyth Street Atlanta, Georgia
GA00088ZZ
N1826380 Brandy Nabors
Elbert P Tuttle Court of Appeals Building
Resident Judge’s Chambers on 4
Interior renovation of Court of Appeals Judge's Chambers on fourth floor
A401 1/4" = 1'-0" A2 Fourth Floor-New NonResident
A. ALL DIMENSIONS ARE TO FACE OF FINISHED SURFACES, UNLESS OTHERWISE NOTED.
B. SURFACES INDICATED TO BE ALIGNED ARE TO HAVE FINISH SURFACES FLUSH WITH ONE ANOTHER.
C. COORDINATE ALIGNMENT OF FIRE SPRINKLERS WITH RECESSED LIGHT FIXTURES, AS INDICATED.
D. IT IS THE INTENT OF THE CEILING DESIGN TO MAXIMIZE CEILING HEIGHTS. MEPFP COMPONENTS
SHALL BE INSTALLED AS HIGH AS POSSIBLE TO ACHIVE DESIGN INTENT. IF NOTED CEILING
HIEIGHTS CAN BE RAISED, COORDINATE WITH ARCHITECT OR…