This solicitation is for general construction services for renovations to resident and non-resident judges' chambers at the Elbert P. Tuttle Federal Building in Atlanta, Georgia. The General Services Administration intends to award a firm-fixed-price contract to a single offeror to renovate two resident judge chambers and four non-resident judge chambers. The estimated construction price range is between $1,000,000 to $5,000,000. This opportunity is set aside for small businesses only. Offerors should submit technical and price proposals, which will be evaluated separately according to Federal Acquisition Regulation Part 15. The solicitation is prepared in accordance with FAR Part 15 and will use the Lowest Price Technically Acceptable selection procedure.

View the file

Other files

File Type Posted
Solicitation Amendment 47PE0221R0011 0002.pdf PDF
solicitation 24 August 2021.pdf PDF
solicitation 24 August 2021.pdf PDF
Solicitation Amendment 47PE0221R0011 0002.pdf PDF
Solicitation Amendment 47PE0221R0011 0002.pdf PDF
solicitation 24 August 2021.pdf PDF
Answered RFIs 15 June 2021.xlsx XLSX spreadsheet
Amendment 1442 15 June 2021.pdf PDF
Tab 5 Wage Determination 26 April 2021.pdf PDF
SOW OPTION 2 Resident Chambers 450 and Non Resident Chambers 442 CD DWGS 2021 03 17 (2).pdf PDF
Agreement 19 April 2021.docx DOCX document
Reps and Certs 19 April 2021.docx DOCX document
Site Visit Registration.docx DOCX document
solicitation 19 april 2021.docx DOCX document
1442 soliciation 5 May 2021.pdf PDF
1442 soliciation 5 May 2021.pdf PDF
SOW OPTION 3 Non Resident Chambers 216 CD PM 2021 03 17.pdf PDF
solicitation 19 april 2021.docx DOCX document
Bid Summary Sheet 5 May 2021.docx DOCX document
SOW OPTION 1 Resident Chambers 270 CD PM 2021 03 17 (3).pdf PDF
Agreement 19 April 2021.docx DOCX document
SOW COVER AND DIVISION 1 2021 03 14.pdf PDF
Reps and Certs 19 April 2021.docx DOCX document
SOW OPTION 1 Resident Chambers 270 CD DWGS 2021 03 17 (1).pdf PDF
SOW OPTION 2 Resident Chambers 450 and Non Resident Chambers 442 CD PM 2021 03 17 (1).pdf PDF
SOW OPTION 4 Non Resident Chambers 233 CD DWGS 2021 03 17 (1).pdf PDF
Site Visit Registration.docx DOCX document
SOW OPTION 4 Non Resident Chambers 233 CD PM 2021 03 17.pdf PDF
SOW OPTION 3 Non Resident Chambers 216 CD DWGS 2021 03 17 (1).pdf PDF
SOW OPTION 4 Non Resident Chambers 233 Pre-Renovation ACM and LBP Sampling Report 2021 03 17 (1).pdf PDF
SOW BASE Non Resident Chambers 238 and 434 CD PM 2021 03 17 (1).pdf PDF
SOW BASE Non Resident Chambers 216 and 238 and 434 Pre-Renovation ACM and LBP Survey Report (1).pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Room name

1i

1t

A101

SIM

ROOM INDICATOR

SLOPE INDICATOR

DETAIL INDICATOR

KP

CR

SECURITY KEYPAD

SECURITY CAMERA

CARD READER ACCESS

TO BE REMOVED (DEMO SHEETS)

EXISTING TO REMAIN

NEW

HIDDEN FEATURES LINE

CENTER LINE

2 HOUR RATED WALL

1 HOUR RATED WALL

PATH OF EGRESS

EGRESS DOOR

# OF ROOM OCCUPANTS

ROOM OCCUPANCY TYPE

A #

OCC.

EXIT EXIT SIGN

NORTH INDICATOR

BUILDING SECTION INDICATOR

WALL SECTION INDICATOR

BREAK LINE INDICATOR

WALL TYPE TAG INDICATOR

WINDOW TYPE TAG INDICATOR

2 41 8

GRAPHIC SCALE, 1/8" = 1'-0"

DOOR TAG INDICATOR

ELEVATION INDICATOR

CENTER LINE

M

06 41 00.PL KEYNOTE INDICATOR

(SEE PROJECT MANUAL)

0 GRID LINE

A101

SIM

INTERIOR ELEVATION INDICATOR

A101 EXTERIOR ELEVATION INDICATOR

CALLOUT INDICATOR

DRAWING TITLE

DIMENSION LINE

FIRE/HORN STROBE

MOTION DETECTOR

1 View Name A101 1/8" = 1'-0"

A101

SIM

A101

SIM

A101

1 Ref

Re f

Re f

1 Ref

2ND FL 4TH FL

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

CIVIL ENGINEER:

MEP ENGINEER:STRUCTURAL ENGINEER:

ARCHITECT:

Occupancy Type:

Construction Type:

Fire Suppression:

Project Name:Key Plan: Project Information:

Project Team:

Drawing List:

W:\Projects\1855_GSA DB Goldbold and Tuttle\cadd\1855_Tuttle 238 434 _ Revit 2020.rvt

6/12/2020 6:09:21 PM

G001

05/21/20

CONSTRUCTION DOCUMENTS

COVER SHEET

gb

GW

Johnson Spellman & Assoc.

350 Research Court Suite 130 Peachtree Corners, GA 30092 678.336.5427

Westside Engineering 5525 Interstate North Parkway- Suite 200 Atlanta, GA 30328 404.965.1287

Houser Walker Architecture 1819 Peachtree Rd NE Suite 102 Atlanta, GA 30309 404.633.4264

Nonresident Chambers Renov. - Ch. 238, 434 Elbert P. Tuttle Court of Appeals 56 Forsyth Street NW Atlanta, GA

Existing, Business

Existing 2B (IBC) ; Type II (LSC)

Existing, Sprinklered

56 Forsyth Street Atlanta, Georgia

N1697519 Brandy Nabors

Elbert P Tuttle Court of Appeals Building

Nonresident Chambers Renovations

Nonresident Chambers 238 and 434

Number Sheet Name 05 /2

1/

C

D S

C ur re nt

R ev isi on

G GENERAL

G001 COVER SHEET O

G002 GENERAL NOTES, KEYNOTES LIST O

AD ARCHITECTURAL DEMOLITION

AD100 NON RESIDENT CHAMBERS - DEMO PLAN O

A ARCHITECTURAL

A100 NON RESIDENT CHAMBERS – PLAN O

A300 ENLARGED BATHROOM PLANS / ELEVATIONS O

A400 NON-RESIDENT CHAMBERS – RCP O

A510 MILLWORK DETAILS O

AI100 FURNITURE AND RCP COORDINATION O

M MECHANICAL

M001 HVAC LEGENDS AND ABBREVIATIONS O

M100 HVAC DEMO PLAN O

M200 HVAC NEW WORK PLAN O

M400 HVAC DETAILS O

M500 HVAC SCHEDULES, CONTROL SEQUENCES AND I/O SUMMARY O

E ELECTRICAL

E001 NOTES DETAILS AND LEGEND O

E100 RISER DIAGRAMS O

E101 PANEL SCHEDULES O

E200 ELECTRICAL PLAN 238 AND 434 O

ED100 DEMOLITION PLAN O

P PLUMBING

P000 PLUMBING LEGEND, SCHEDULES AND NOTES O

P100 Plumbing Demolition O

P200 PLUMBING PLANS O

FP FIRE PROTECTION

FP200 FIRE PROTECTION PLANS O

O = Current Issued NOT for Construction P = Previously Issued = Not Issued (blank) i = For Information Only

MPFP ENGINEER:ELECTRICAL ENGINEER :

Legend:

100% Construction Documents

ST

ATE OF GEORGI A

REGI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

05/06/19

Revision Number

Revision Date Revision Description

Key:

2ND FL KEY PLAN4TH FL KEY PLAN

TYPE CW

HISTORIC REFINISHED COPPER EXTERIOR WINDOW. STRIP EXISTING PAINT AND

REFURBISH COPPER TO MATCH BUILDING STANDARD COPPER WINDOWS. CLEAR

LACQUER FINISH OVER POLISHED COPPER.

REFINISH HISTORIC

WINDOW COPPER

EXISTING TRIM TO

REMAIN. PAINT PT-2

TYPE WD

EXISTING REFINISHED WOOD WINDOW. STRIP EXISTING PAINT FROM TRIM AND

GLASS AND REFINISH TRIM.

PAINT PT-2

STRIP EXISTING

PAINT FROM

GLASS SURFACE

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

W:\Projects\1855_GSA DB Goldbold and Tuttle\cadd\1855_Tuttle 238 434 _ Revit 2020.rvt

6/12/2020 6:09:27 PM

G002

05/21/20

CONSTRUCTION DOCUMENTS

GENERAL NOTES, KEYNOTES LIST

gb

GW

56 Forsyth Street Atlanta, Georgia

N1697519 Brandy Nabors

Elbert P Tuttle Court of Appeals Building

Nonresident Chambers Renovations

Nonresident Chambers 238 and 434

1. THE CONTRACTOR SHALL MAINTAIN AT THE SITE FOR THE OWNER ONE COPY OF THE DRAWINGS, SPECIFICATIONS, ADDENDA, CHANGE ORDERS AND OTHER MODIFICATIONS, IN GOOD ORDER AND MARKED CURRENTLY TO INDICATE FIELD CHANGES AND SELECTIONS MADE DURING CONSTRUCTION, AND ONE COPY OF APPROVED SHOP DRAWINGS, PRODUCT DATA, SAMPLES, AND SIMILAR

REQUIRED SUBMITTALS.

2. THE CONTRACTOR SHALL PERFORM WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.

3. THE DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY AND ARE TO BE UNDERSTOOD COMPREHENSIVELY. ORGANIZATION AND ARRANGEMENT OF THE DRAWINGS AND/ OR SPECIFICATIONS INTO DIVISIONS, SECTIONS AND ARTICLES SHALL NOT CONTROL THE CONTRACTOR IN DIVIDING THE WORK AMONG SUBCONTRACTORS OR IN ESTABLISHING THE EXTENT OF WORK TO BE PERFORMED BY

ANY TRADE.

4. BECAUSE THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, THE CONTRACTOR SHALL, BEFORE STARTING EACH PORTION OF THE WORK, CAREFULLY STUDY AND COMPARE THE VARIOUS CONTRACT DOCUMENTS RELATIVE TO THAT PORTION OF THE WORK, SHALL TAKE FIELD MEASUREMENTS OF ANY EXISTING CONDITIONS RELATED TO THAT PORTION OF THE WORK, AND SHALL OBSERVE ANY CONDITION AT THE SITE AFFECTING IT. THESE OBLIGATIONS ARE FOR THE PURPOSE OF FACILITATING COORDINATION AND CONSTRUCTION BY THE CONTRACTOR AND ARE NOT FOR THE PURPOSE OF DISCOVERING ERRORS, OMISSIONS, OR INCONSISTENCIES IN THE CONTRACT DOCUMENTS. HOWEVER, THE CONTRACTOR SHALL PROMPTLY REPORT TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES OR OMISSIONS DISCOVERED BY OR MADE KNOWN TO THE CONTRACTOR AS REQUEST FOR INFORMATION.

5. DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION.

Contract Documents

Existing Conditions

1. EXISTING ADJACENT PORTIONS OF THE BUILDING ARE TO REMAIN OPERATIONAL THROUGHOUT CONSTRUCTION. COORDINATE CONSTRUCTION ACTIVITIES AND PHASING WITH ARCHITECT, GSA COR, AND TENANT REPRESENTATIVE TO MINIMIZE DISRUPTIONS TO

OWNER’S OPERATIONS AND ACCESS, AND TO ENSURE SAFETY OF OCCUPANTS.

2. ATTENTION IS CALLED TO THE FACT THAT THIS PROJECT IS A RENOVATION OF AN EXISTING BUILDING. RENOVATION OF EXISTING BUILDINGS REQUIRE THOROUGH COORDINATION OF THE CONTRACT DOCUMENTS WITH THE EXISTING CONDITIONS. THE CONTRACTOR MUST VERIFY ALL RELEVANT EXISTING CONDITIONS, DIMENSIONS, AND DETAILS PRIOR TO BEGINNING CONSTRUCTION.

3. ALL DRAWINGS AND DETAILS INCORPORATING EXISTING CONDITIONS ARE REPRESENTATIONS OF EXISTING CONDITIONS ONLY.

THE CONTRACTOR SHALL VERIFY THE ACCURACY OF ACTUAL CONDITIONS AND COORDINATE WITH THE ARCHITECT ANY DEVIATIONS OF

THE DETAILS SO TO EXECUTE THE INTENT OF THE DRAWING OR DETAIL.

4. FIELD VERIFY EXISTING DIMENSIONS PRIOR TO ORDERING OR CUTTING MATERIALS.

5. CUTTING AND PATCHING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING, FITTING OR PATCHING REQUIRED TO COMPLETE THE WORK OR TO MAKE PARTS FIT TOGETHER PROPERLY. ALL AREAS REQUIRING CUTTING, FITTING AND PATCHING SHALL BE

RESTORED TO THE CONDITION EXISTING PRIOR TO CUTTING, FITTING AND PATCHING.

6. REMOVE COMPLETELY MATERIALS AS INDICATED ON THE DRAWINGS AND AS REQUIRED FOR NEW CONSTRUCTION. EDGES AND FACES OF DEMOLISHED AREAS SHALL BE REPAIRED TO ACCEPT NEAT INSTALLATION OF NEW CONSTRUCTION OR FINISHES. WHERE EXISTING MATERIALS ARE TO BE REPLACED, EXISTING MATERIALS, ADHESIVES, ETC. SHALL BE REMOVED AND EXPOSED SURFACES SHALL BE

REPAIRED AS RECOMMENDED BY MANUFACTURER PRIOR TO INSTALLATION OF NEW MATERIALS.

7. PATCH ALL EXISTING HOLES AND VOIDS AND PATCH HOLES CAUSED BY THE REMOVAL OF EQUIPMENT, PIPING, CONDUIT, DUCT, GRILLS, ETC WITH MATERIALS MATCHING EXISTING.

8. WHERE FINISH SCHEDULE SHOWS EXISTING FINISHES TO REMAIN, THESE FINISHES TO BE REPAIRED AND/ OR EXTENDED TO BE

SEAMLESS WITH RENOVATED AREAS.

9. SURFACES OF NEW AND EXISTING FINISHES ARE TO MATCH IN COLOR, TEXTURE AND CONSISTENCY, UNLESS NOTED OTHERWISE.

10. CONTRACTOR IS RESPONSIBLE FOR REROUTING ANY EXISTING CONDUITS, WIRING, PLUMBING AND PIPING AS REQUIRED TO ACHIEVE THE DESIRED LAYOUT AND DESIGN INTENT SHOWN. NEW REROUTING LOCATIONS SHALL BE CONCEALED WITHIN WALL. WHEN IT IS IMPOSSIBLE TO CONCEAL ITEMS, LOCATE ITEMS TIGHT AGAINST WALLS- ENCLOSE ITEMS WITH GYPSUM WALL BOARD WITHOUT

DISRUPTION OF SERVICE TO OTHER AREAS.

Other General Requirements

General Notes: Renovated Area:

2858 sf

Occupant Load: (LSC 7.3.1.2) Business: 100 gross sf/person Storage: NA

Second Floor Non-Resident: 1850 SF Business = 19 people

Fourth Floor Non-Resident: 1008 SF Business = 11 people

Egress Capacity: (LSC 7.3.3) Stairs: 0.3" / person

Level components and ramps: 0.2"/per Maximum Travel Distance: (LSC 7.6.1)

Business: 300 ft Storage: NA

Maximum Dead End Limit: (LSC 7.6.1) Business: 50 ft Storage: NA

Maximum Common Path of Travel: (LSC 7.6.1) Business: 100 ft Storage: NA

Building Component Ratings:

Structural Frame: 0 hrs Bearing Walls: 0 hrs Nonbearing walls: 0 Floor Construction: 0 hrs Roof Construction: 0 hr

Rated Separations:

Shaft enclosure: 2 hr

Corridors: 2 hr Interior Finish Limitations:

Class A or B in all spaces, except Exits Class A in Exits

APPLICABLE CODES & STANDARDS

APPLICABLE CODES & STANDARDS

- INTERNATIONAL BUILDING CODE:

2018 EDITION

- NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101

LIFE SAFETY CODE (LSC):

2018 EDITION

- INTERNATIONAL FUEL GAS CODE:

2018 EDITION

- INTERNATIONAL MECHANICAL CODE:

2018 EDITION

- INTERNATIONAL PLUMBING CODE:

2012 EDITION

- NATIONAL ELECTRICAL CODE (NEC):

2017 EDITION

- INTERNATIONAL FIRE CODE

2018 EDITION

- INTERNATIONAL ENERGY CONSERVATION CODE:

2015 EDITION

- FACILITIES STANDARDS FOR THE PUBLIC BUILDING

SERVICE- PBS-P100, 2018 EDITION.

- ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD

(ABAAS), LATEST EDITION.

- US COURTS DESIGN GUIDE, LATEST EDITION.

1. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE CONTRACTOR’S BEST SKILL AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR, AND HAVE CONTROL OVER, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK. IF THE CONTRACT DOCUMENTS GIVE SPECIFIC INSTRUCTIONS CONCERNING CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, THE CONTRACTOR SHALL EVALUATE THE JOBSITE SAFETY THEREOF, AND SHALL BE FULLY RESPONSIBLE FOR THE JOBSITE SAFETY ASSOCIATED WITH SUCH INSTRUCTIONS. IF THE CONTRACTOR DETERMINES THAT SUCH INSTRUCTIONS MAY NOT BE SAFE, THE CONTRACTOR SHALL GIVE TIMELY WRITTEN NOTICE TO THE OWNER AND ARCHITECT AND SHALL NOT PROCEED WITH THAT PORTION OF THE WORK WITHOUT

FURTHER WRITTEN INSTRUCTIONS FROM THE ARCHITECT.

2. THE CONTRACTOR SHALL EMPLOY A COMPETENT SUPERINTENDENT AND NECESSARY ASSISTANTS WHO SHALL BE IN ATTENDANCE AT THE PROJECT SITE DURING PERFORMANCE OF THE WORK. THE SUPERINTENDENT SHALL REPRESENT THE CONTRACTOR AND COMMUNICATIONS GIVEN THE SUPERINTENDENT SHALL BE BINDING AS IF GIVEN TO THE CONTRACTOR.

3. DEMOLITION DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. CONTRACTOR SHALL CLEAN JOBSITE DAILY, MAINTAIN A CLEAN WORKPLACE AND KEEP CONSTRUCTION DEBRIS AND DUST AWAY FROM ADJACENT BUILDING OCCUPANTS.

4. INSTALL BLOCKING IN ALL WALLS INDICATED TO RECEIVE WALL MOUNTED DEVICES AND/ OR CABINETRY.

5. ALL WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED.

6. PROVIDE DOUBLE STUDS AT ALL OPENINGS IN WALLS.

7. NOT USED.

8. ALL VERTICAL RATED MECHANICAL CHASE ASSEMBLIES SHALL EXTEND FROM FLOOR FINISH TO STRUCTURE ABOVE.

10. ALL EXPOSED ELECTRICAL, FIRE PROTECTION, AND MECHANICAL DEVICES SHALL BE CENTERED ON OR ALIGN WITH

ARCHITECTURAL FEATURES AS SHOWN ON THE REFLECTED CEILING PLANS.

11. OPENINGS CREATED IN SLABS, SMOKE PARTITIONS, OR FIRE RATED PARTITIONS BY THIS WORK SHALL BE REPAIRED USING TECHNIQUES AND MATERIALS TO MAINTAIN THE RATING OF THE WALL, INCLUDING BUT NOT LIMITED TO SMOKE DAMPERS, FIRE DAMPERS, FIRESTOPPING, AND FIRE SAFING, PENETRATIONS OF MASONRY WALLS AND CONCRETE FLOORS SHALL BE STOPPED TO

MINIMUM 2 HOUR RATING.

12. CONTRACTOR IS TO COORDINATE WITH OWNER PROVIDED MATERIALS & SERVICES, INCLUDING: SECURITY EQUIPMENT AND

BREAKROOM APPLIANCES.

13. ALL DIMENSIONS ARE TO FACE OF FINISHED SURFACES, UNLESS NOTED OTHERWISE.

14. RELOCATE EXISTING FIRE SPRINKLER MAINS, BRANCHES, AND HEADS TO ACCOMODATE SPECIFIED CEILING HEIGHTS, CEILING

CONFIGURATION, AND LIGHTING LAYOUT.

ST

ATE OF GEORGI A

REGI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

05/06/19

Revision Number

Revision

Window Types and Schedule:

JUDGE'S

CHAMBERS

CLOSET

247B

TOILET

247ABREAK RM.

JUDICIAL

ADMIN

LAW CLERK

LAW CLERK

LIBRARY

NOTE 1

NOTE 1

NOTE 1

NOTE 1

NOTE 1

NOTE 1,2

NOTE 1

NOTE 1

NOTE 3

TOILET

JUDGE'S

CHAMBERS

JUDICIAL

ADMIN

LAW CLERKS

VESTIBULE

NOTE 1 NOTE 1 NOTE 1

NOTE 1

NOTE 1, 2

2ND FL KEY PLAN4TH FL KEY PLAN

To Be Removed

Existing To Remain

PRESUMED ASBESTOS CONTAINING

TILE UNDER EXISTING FINISH

UNKOWN UNDERLAYMENT

FILL PATTERN LEGEND

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES

C:\Users\HWA17\Documents\1855_Tuttle 238 434 _ Rev 2020_octavian@houserwalker.com.rvt

3/17/2021 7:07:46 PM

AD100

05/21/20

CONSTRUCTION DOCUMENTS

NON RESIDENT CHAMBERS - DEMO PLAN

gb

GW

56 Forsyth Street Atlanta, Georgia

N1697519 Brandy Nabors

Elbert P Tuttle Court of Appeals Building

Nonresident Chambers Renovations

Nonresident Chambers 238 and 434

1. REMOVE EXISTING CARPET AND PADDING. AT AREAS IDENTIFIED TO BE CONTAINING ACM FLOORING, REMOVE EXISTING TILE AND MASTIC, LEAVING EXISTING WOOD FLOOR IN PLACE. IF WOOD FLOORING IS DAMAGED, REPLACE WITH LIKE KIND AND PREP FOR NEW FLOOR FINISH. REMOVE WALL COVERING, ACT CEILING, LIGHTING, ALL ABANDONED PIPING AND ALL ABANDONED CONDUIT, AS EXISTS.

2. REMOVE EXISTING FIXTURES, SEE PLUMBING DRAWINGS. REMOVE FLOOR TILE, WALL TILE, TOILET ACCESSORIES, CEILINGS, LIGHTING, AND WALLS AS NOTED.

3. REMOVE AND SALVAGE EXISTING DOOR TO BE REFURBISHED AND REINSTALLED AS PART OF THE NEW WORK. PROTECT DURING CONSTRUCTION EXISTING

WOOD CASINGS TO REMAIN.

4. REPAIR EXTERIOR PLASTER WALLS WHERE EXISTING WALLS HAVE BEEN DEMOLISHED AND WHERE DAMAGE IN FINISH OCCURS.

A. RELOCATE EXISTING FIRE SPRINKLER MAINS, BRANCHES, AND HEADS TO ACCOMODATE SPECIFIED CEILING HEIGHTS, CEILING CONFIGURATION, AND LIGHTING

LAYOUT.

B. CONTRACTOR TO SEAL, CAULK, AND IN-FILL ANY EXISTING AND NEW PENETRATIONS OR OPENINGS AT ALL WALLS LOCATED WITHIN THE SCOPE OF WORK AREA AS

REQUIRED FOR COMPLETELY ACOUSTICALLY SEALED CONDITION BOTH SIDES, TYP.

C. CONTRACTOR IS RESPONSIBLE FOR REROUTING ANY EXISTING CONDUITS, WIRING, PLUMBING AND PIPING AS REQUIRED TO ACHIEVE THE DESIRED LAYOUT AND DESIGN INTENT SHOWN. NEW REROUTING LOCATIONS SHALL BE CONCEALED WITHIN WALL. WHEN IT IS IMPOSSIBLE TO CONCEAL ITEMS, LOCATE ITEMS TIGHT AGAINST WALLS- ENCLOSE ITEMS WITH GYPSUM WALL BOARD WITHOUT DISRUPTION OF SERVICE TO OTHER AREAS.

D. ALL WINDOW TRIM, JAMBS AND SILLS TO REMAIN. PROTECT EXISTING WINDOWS AND DOORS TO REMAIN DURING CONSTRUCTION.

ST

ATE OF GEORGI A

REGI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

05/06/19

AD100 3/16" = 1'-0"

H2 SECOND FLOOR - CH 238 - DEMO

AD100 3/16" = 1'-0"

A6 FORTH FLOOR - CH 434 - DEMO

Revision Number

Revision Date Revision Description

ABATEMENT NOTES A. REMOVE AND ABATE ASBESTOS CONTAINING 9X9 TILE AND MASTIC, WHERE PRESENT, BELOW THE EXISTING CARPET AND PADDING. IT IS ESTIMATED THAT APPROXIMATELY 600 SQUARE FEET OF TILE ARE PRESENT IN EACH OF THE CHAMBERS BUT THE EXACT QUANTITY IS UNKNOWN. REPORT OF LIMITED PRE-RENOVATION ASBETOS CONTAINING MATERIAL AND LEAD BASED PAINT SAMPLING FOR TUTTLE / GODBOLD RENOVATIONS, NOVA PROJECT NO.3019150 10/25/19 IS AVAILABLE AS APPENDIX TO THESE CONTRACT DOCUMENTS.

B. HAZARDOUS MATERIAL SAMPLYING HAS IDENTIFIED LEAD BASED PAINT ON THE EXISTING PLASTER WALLS AND PLASTER CEILINGS. SCHEDULED REMOVAL OF WALLS SHOULD BE DONE IN ACCORDANCE WITH OSHA 1926.62 REGULATIONS GOVERNING LEAD-SAFE PRACTICES. LEAD BASED PAINT IN CEILINGS AND EXISTING TO REMAIN WALLS SHALL BE ABATED VIA ENCAPSULATING PAINT. THE CONTRACTOR SHALL PREPARE FOR ENCAPSULATION BY REMOVING LOOSE AND FLAKING PAINT BY WET SCRAPING. REFER TO 09 9020.

C. FOR LBP ENCAPSULATION ABATEMENT, THE MEANS AND METHODS FOR WORKER PROTECTION AND MONITORING, ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL COMPLY WITH CURRENT OSHA 1926.62 LEAD REGULATIONS FOR LEAD SAFETY RELATED TO OCCUAPATIONAL HAZARDS.

D. ABATE ALL EXISTING PIPING WITHIN SCOPE OF WORK WRAPPED IN ASBESTOS CONTAINING MATERIALS, KNOWN AS THERMAL SYSTEM INSULATION (TSI).

FILL PATTERN LEGEND

A300 D1

F W

C B

D

CPT-1

PT, WC-1

GWB

EXISTING

F W

C B

D

CPT-1

PT, WC-1

GWB, ACT

EXISTING

F W

C B

D

CPT-1

PT, WC-1

GWB, ACT

EXISTING

F W

C B

D

FT-1

CT-1, WC-2

GWB

TB-1

F W

C B

D

CPT-1

PT, WC-1

ACT

EXISTING

A100

E2

NOTE 3

NOTE 3 NOTE 3, 6 NOTE 3

CW

CW CW CW

CW

DEV DEV DEV

DEV

DEV

LAW CLKS

JUDICIAL

ADMIN

JUDGE'S

CHAMBERS

TOILET

VESTIBULE

NOTE 3

F W

C B

D

CPT-1

PT, WC-1

GWB

EXISTING

F W

C B

D

FT-2

PT, WC-1

GWB, ACT

EXISTING

F W

C B

D

CPT-1

PT, WC-1

GWB, ACT

EXISTING

F W

C B

D

CPT-1

PT, WC-1

ACT

EXISTING

F W

C B

D

CPT-1

PT,WC-1

ACT

EXISTING

F W

C B

D

CPT-1

PT, WC-1

GWB

EXISTING

F W

C B

D

FT-1

CT-1, WC-2

GWB

TB-1

CLOSET

247B

A100 A2

A300 D5

A300H5

A100E2

A5

01 10 00.OOE

01 10 00.OOE

NOTE 3 NOTE 3

NOTE 3

NOTE 3

C5

F W B C D

FLOOR FINISH

WALL FINISH

BASE FINISH

CEILING FINISH

DEVICE COLOR

DEV

DEV

DEV

DEV

DEV

DEV

DEV

LAW CLK

LAW CLK

LIBRARY

JUDICIAL

ADMINISTRATOR

BREAK RM

TOILET

247A

JUDGE'S

CHAMBERS

LEGEND

NOTE 3

A100 E2

A100 E2

NOTE 4,

TYP.

NOTE 1 2' - 6" NOTE 1

NOTE 2

CTOP-1

BACKSPLASH,

CTOP-1

2'

J4

A510

J7

A510

J1

A510

06 41 00.SS

06 41 00.SS

06 41 00.WVC

W C

-1

PT

-2

PT

-1

PT

-2

NOTE 5

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

W:\Projects\1855_GSA DB Goldbold and Tuttle\cadd\1855_Tuttle 238 434 _ Revit 2020.rvt

6/12/2020 6:08:58 PM

A100

05/21/20

CONSTRUCTION DOCUMENTS

NON RESIDENT CHAMBERS – PLAN

gb

GW

56 Forsyth Street Atlanta, Georgia

N1697519 Brandy Nabors

Elbert P Tuttle Court of Appeals Building

Nonresident Chambers Renovations

Nonresident Chambers 238 and 434

01 10 00.OOE OSOI EQUIPMENT

06 41 00.SS SOLID SURFACE

COUNTERTOP

06 41 00.WVC WOOD VENEER CABINET

2 41 8

ST

ATE OF GEORGI A

REGI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

05/06/19

A100 3/16" = 1'-0"

A6 FOURTH FLOOR - CH. 434

A100 3/16" = 1'-0"

H2 SECOND FLOOR - CH. 238

A100 1/2" = 1'-0"

A2 BREAKROOM ELEVATION

A100 1/2" = 1'-0"

E2 TYPICAL ELEVATION

FINISHES SCHEDULE:

TYPE MARK KEYNOTE DESCRIPTION DISTRIBUTOR / MANUF. PRODUCT COMMENTS

ACT ACOUSTICAL CEILING TILE

CT-1 CERAMIC TILE

WC-2

CPT-1

CEILING

WALLS / FLOORING / BASE

FT-1

TB-1

WC-1 WALL COVERING

PT-1 PAINT

WALL COVERING

CERAMIC TILE BASE

CARPET

STONE TILE

FT-2 STONE TILE

CT-2 CERAMIC TILE

PT-2 PAINT

CEILING PAINT

TRIM PAINT

PT-3 PAINT TYPICAL PAINT

ELECTRICAL DEVICES

COVERS AND DEVICES MELJAC CLASSIQUE

1. MAINTAIN DOOR CLEARANCE. FIELD VERIFY

2. ALIGN TOP OF BACKSPLASH WITH TOP OF EXISTING CHAIR RAIL. FIELD VERIFY

3. REFURBISH EXISTING COPPER WINDOWS TO MATCH BUILDING STANDARD

4. PAINT EXISTING BOOKCASE PT-2

5. EXISTING CHAIR RAIL, WHERE PRESENT. ADD NEW CHAIR RAIL TO MATCH, IN LAW CLK 236, 237

6. THE SILL AND BASE EXHIBIT WATER DAMAGE.

A. OBTAIN CLOSE-UP IMAGERY OF THE WINDOW, BEFORE AND DURING A RAIN EVENT. IF RAIN FORECASTS ARE NOT FORTHCOMING DURING THE SCHEDULED PERIOD, USE WATER SPRAY TO INDUCE A LEAK.

B. AFTER A LEAK IS OBSERVED OR INDUCED, PERFORM MOISTURE TESTING AT THE SILL, BASE AND THE VERTICAL AREA IN-BETWEEN.

C. PERFORM DESTRUCTIVE TESTING FROM THE INSIDE, AT AREAS WITH HIGH MOISTURE READINGS, TO UNCOVER EXTENTS OF DAMAGE INSIDE THE WALL.

D. ENGAGE THE SERVICES OF A BUILDING ENVELOPE CONSULTING FIRM FOR FURTHER RECOMMENDATIONS BASED ON THE RESULTS. GC, CONSULTING FIRM AND ARCHITECT WILL COORDINATE A SET OF REMEDIATION ACTIONS THAT THE

ARCHITECT WILL ISSUE AS PART OF AN ADDENDUM.

SEPARATELY, PERFORM A MOLD SURVEY ON THE DEBRIS CURRENTLY PRESENT AROUND THE CRACKS IN THE WINDOW SILL. NOVA ENGINEERING IS BASIS OF DESIGN FOR MOLD SURVEYING AND ENVELOPE CONSULTING.

ARCHITECTURAL CASEWORK

SOLID SURFACECTOP-1 CORIAN

WVC-1 WOOD VENEER

ARMSTRONG ULTIMA

SHERWIN WILLIAMS

09 30 00

09 30 00

09 51 00

09 91 23

09 91 23

09 91 23

09 72 00

09 72 00

09 68 13

09 30 00

06 41 00

06 41 00

WHITE, 24" X 24" X 3/4" BEVELED TEGULAR, NRC 75

M3 PARCHMENT, 3" X 6"HEATH COVE BASE TILE SET BOTTOM EDGE FLUSH TO FLOOR

CEILING BRIGHT WHITE, SW 7007, FLAT

ALL WHITE, SEMIGLOSS

OC-45, SWISS COFFEE, EGGSHELL

FARROW & BALL

BENJAMIN MOORE

FARROW & BALL DRAGGED PAPER, DR 611, ROLL

LUCID, 399632-001 SIBERIAMAHARAM

SAIL CLOTH, ROLLTARKETT ZONA II

M3 PARCHMENT, 3" X 6"

BRONZE MÉDAILLE, CLEAR, SCREWLESS

STORM GREY LEATHERED, 2 CM THICKNESS

GWB GYPSUM CEILING09 21 16

CT-3 CERAMIC TILE09 30 00

HEATH CLASSIC FIELD

HEATH CIRCLE LINEAR TILE

HEATH STEP LINER

M3 PARCHMENT, 1" X 6"

M3 PARCHMENT, 6"

RENAISSANCE TILE & BATH

RENAISSANCE TILE & BATH

GRANDVIEW FAIRMONT 4" X 1" FAIRMONT - PICKET - HONED

GRANDVIEW FAIRMONT 3" X 12" FAIRMONT - HONED

SANDED GROUT COLOR 'FG-1' TO BE SELECTED BY

ARCHITECT FROM MERKRETE AND LATICRETE'S FULL

COLOR OFFERINGS. ONE FULL COURSE OF FT-2

BORDER AT WALL.

GLUED

GROUT COLOR TO BE SELECTED BY ARCHITECT

1 COURSE, AS INDICATED

TOP COURSE, AS INDICATED

ONE PUSH BUTTON, ORIENT TO EXISTING POSITION

WHITE OAK, OPAQUE STAIN, COLOR TBD

DEV

MATERIAL KEYNOTES SHEET SPECIFIC NOTES

Revision Number

Revision

ALIGN TOP W/ TOP

OF DOOR FRAME

WC-2

A7

A300

2' - 6"

2' - 0"

3'

0"

J4

A510 J7

A510

VIF 1' - 9" 1' - 2 1/2"

J1

A510

10 28 00.PTD

10 28 00.M

06 41 00.WVC

10 28 00.SD

A300H5

A5

SOAP DISPENSER

A300 K7

C5

J4

A510

J7

A510

J1

A510

10 28 00.TP

CW

2' - 5"

OF WALL AND MIRROR

ALIGN TOP OF MIRROR

W/ TOP OF DOOR

ALIGN W TILE

COURSING

D4

A300

10 28 00.M

A300H1

A300 A1

A3

A300 K7

10 28 00.TP

WC-2

ARCHITECTURAL

WOODWORK

CTOP-1

A7

A300

06 41 00.WVC

06 41 00.SS

2ND FL KEY PLAN4TH FL KEY PLAN

TB-1

3/

4" 2"

1" 3'

1/ 8"C

T-

T

IL

E

C O

UR

SE

S

C T-

C

T-

C T-

C

O U

RS

E

C

O U

RS

E

C

O U

RS

E

, NOTE 107 92 00

TB-1

FT-2 FT-1

FT

-2

NOTE 2

ONE FULL TILE

HALF TILE

ALIGN W/ TILE

COURSING

6"1' - 10"

ALIGN W/ TOP

OF DOOR FRAME

D4

A300

10 28 00.M

3/4"

PANEL MOULDING.

P&P PM-2149

MIRROR SURFACE

ALIGN

3' - 0"

VIF

EQ

VIF

EQ

3'

0"

3' - 0"

OF WALL, MIRROR, SINK AND CABINET

ALIGN,

NOTE 3

10 28 00.M

06 41 00.SS

06 41 00.WVC

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

MATERIAL KEYNOTES

GENERAL NOTES

SHEET SPECIFIC NOTES

C:\Users\HWA17\Documents\1855_Tuttle 238 434 _ Rev 2020_octavian@houserwalker.com.rvt

3/17/2021 7:03:52 PM

A300

05/21/20

CONSTRUCTION DOCUMENTS

ENLARGED BATHROOM PLANS /

ELEVATIONS

gb

GW

56 Forsyth Street Atlanta, Georgia

N1697519 Brandy Nabors

Elbert P Tuttle Court of Appeals Building

Nonresident Chambers Renovations

Nonresident Chambers 238 and 434

1 2 4

ST

ATE OF GEORGI A

REGI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

05/06/19

A300 1/2" = 1'-0"

H5 CH. 238 - TOILET EAST ELEVATION

A300 1/2" = 1'-0"

D5 CH. 238 - TOILET ENLARGED PLAN

A300 1/2" = 1'-0"

H1 CH.434 TOILET EAST ELEVATION

A300 1/2" = 1'-0"

D1 CH. 434 - TOILET ENLARGED PLAN

A300 1/2" = 1'-0"

A1 CH. 434 - TOILET WEST ELEV

A300 1/2" = 1'-0"

A5 CH. 238 - TOILET NORTH ELEVATION

Revision Number

Revision Date Revision Description

A300 12" = 1'-0"

A7 TYP. SECTION DETAIL AT WALL TILE

1. USE SEALANT INSTEAD OF GROUT

WHERE TILE BASE AND FLOOR TILE

MEET. COLOR TO BE SELECTED BY

ARCHITECT

2. EXISTING TRANSITION TRIM TO

REMAIN

3. ALIGN TOP OF MIRROR WITH TOP OF

DOOR FRAME.

A300 3" = 1'-0"

K7 TYP. PLAN DETAIL AT FLOOR TILE

A300 1/2" = 1'-0"

C5 CH.238 - TOILET SOUTH ELEV

A300

D4 MIRROR FRAME DETAIL

A300 1/2" = 1'-0"

A3 CH. 434 - TOILET NORTH ELEV

RECESSED

LIGHT FIXTURES

HVAC

SUPPLY

DIFFUSER

PENDANT

SPRINKLER

HEAD

ACCESS PANELCASEWORK

SIDEWALL

SPRINKLER

HEAD

HVAC

RETURN

DIFFUSER

PENDANT

LIGHT FIXTURES

RECESSED TROFFER

LIGHT FIXTURES

EXIT SIGN

EQ EQ

JUDGE'S

CHAMBERS

JUDICIAL

ADMIN

LAW CLKS

EQ

EQ

8' - 6"

9' - 11"

9' - 7 1/2"

, TYP.

AREA OF NO WORK

EQ EQ

A2

A400

TOILET

8' - 6"

09 21 16.CL

09 51 00 , TYP.09 21 16.CL , TYP.

A1

A510

8' - 6"

08 31 00.AP08 31 00.AP

A1

A510

TYP.

A1

A510 TYP.

9' - 8" 9' - 8"

09 21 16.CL, TYP.

EQ

EQ

EQ

EQ5'

1/ 2"

EQ EQ

2' - 4"

EQ "B1" 12' - 0"

EQ "B1"

/2

EQ

EQ "B2" EQ "B2"

BREAK RM

JUDICIAL

ADMINISTRATOR

CLOSET

247B

TOILET

247A

LAW CLK

LAW CLK

LIBRARY

JUDGE'S

CHAMBERS

EQ EQ

EQ

EQ

10' - 0"

10' - 4 1/2"

7" 7"EQ EQ EQ EQ

7"

1'

7" 1'

7"

EQ

EQ

,TYP.

, TYP.A

RE

A O

F N

O W

O

RK

8' - 6"

8' - 6"

8' - 6"

8' - 6"

9' - 0"

8' - 6"

EQ EQ EQ

09 21 16.CL

09 51 00

A2

A400

08 31 00.AP

A1

A510

TYP

8' - 0" EQ "A2"EQ "A2"

EQ "A1" 8' - 0" EQ "A1"

EQ "A3" 8' - 0" EQ "A3"

EQ

EQ

EQ

EQ

EQ

EQ

ALIGN

A1

A510

TYP

A1

A510

A1

A510

EQ

EQ

EQ "A"EQ "A" 8' - 10"

1 1/4" BED MOULDING.

P&P PM-1186

5" CROWN MOULDING.

P&P PM-1003

4" CROWN MOULDING.

P&P PM-1100

PICTURE RAIL

5/ 8"

3 1/2"

1/

4"

3 1/2"

ALIGN BOTTOM OF TRIM WITH TOP

OF EXISTING WINDOW FRAME.

A510 D1

1/ 4"

06 20 00.CT

06 20 00.CT

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES

W:\Projects\1855_GSA DB Goldbold and Tuttle\cadd\1855_Tuttle 238 434 _ Revit 2020.rvt

6/12/2020 6:09:09 PM

A400

05/21/20

CONSTRUCTION DOCUMENTS

NON-RESIDENT CHAMBERS – RCP

OT

GW

56 Forsyth Street Atlanta, Georgia

N1697519 Brandy Nabors

Elbert P Tuttle Court of Appeals Building

Nonresident Chambers Renovations

Nonresident Chambers 238 and 434

06 20 00.CT CEILING TRIM

08 31 00.AP ACCESS PANEL

09 21 16.CL GYPSUM WALLBOARD-CEILING

09 51 00 ACOUSTICAL CEILINGS

A. ALL DIMENSIONS ARE TO FACE OF FINISHED SURFACES, UNLESS OTHERWISE NOTED.

B. SURFACES INDICATED TO BE ALIGNED ARE TO HAVE FINISH SURFACES FLUSH WITH ONE ANOTHER.

C. COORDINATE ALIGNMENT OF FIRE SPRINKLERS WITH RECESSED LIGHT FIXTURES, AS INDICATED.

D. IT IS THE INTENT OF THE CEILING DESIGN TO MAXIMIZE CEILING HEIGHTS. MEPFP COMPONENTS

SHALL BE INSTALLED AS HIGH AS POSSIBLE TO ACHIEVE DESIGN INTENT. IF NOTED CEILING

HEIGHTS CAN BE RAISED, COORDINATE WITH ARCHITECT OR OWNER REPRESENTATIVE.

Ceiling Legend

ST

ATE OF GEORGI A

REGI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

05/06/19

A400 3/16" = 1'-0"

A6 FOURTH FLOOR - CH 434 - RCP

A400 3/16" = 1'-0"

H2 SECOND FL - CH 238 - RCP

A400 3" = 1'-0"

A2 SOFFIT DETAIL

Revision Number

2' - 0"

3'

0"

CTOP-1.

EASED EDGES

FACE

FRAME

3"

2'

/8

1/

4" 4"

1"

3/ 8"

1"

3/ 8"

1"

3/ 8"

1"

3/ 8"

1/

4" 3"

CENTER PULL ON

DRAWER, TYP.

1/2"

A510 F1

06 41 00.DP

06 41 00.SS

06 41 00.WVC

3'

0"

CTOP-1.

EASED EDGES

1/

4" 4"

1"

1/ 4"

2'

5/

8"

TY

P.

1/

4"

FACE

FRAME

INSET DOOR

W 1/8"

RECESSED

PANEL, TYP.

3"3"

1/2"

06 41 00.WVC

06 41 00.SS

2' - 0"

3'

0"

CTOP-1.

EASED EDGES

1/

4" 1"

/8

/8

TY

P.

1/

4"

FACE

FRAME

INSET DOOR

W 1/8"

RECESSED

PANEL, TYP.

3"3"

1/

4" 4"

1"

2'

/8

10 28 00.PTD

06 41 00.SS

06 41 00.WVC

1/8"

06 41 00.WVC

3/4"

1/

2"

5/16"

3/8"

7/

8"

06 20 00.CT

SEE PLAN

1 1/4" BED MOULDING.

P&P PM-1186

5" CROWN MOULDING.

P&P PM-1003

06 20 00.CT

ACT IN ROOMS 236, 237,

238, 246, 433, 435, GYP IN

ROOMS 247 AND 431

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

MATERIAL KEYNOTES

GENERAL NOTES

SHEET SPECIFIC NOTES

W:\Projects\1855_GSA DB Goldbold and Tuttle\cadd\1855_Tuttle 238 434 _ Revit 2020.rvt

6/12/2020 6:09:11 PM

A510

05/21/20

CONSTRUCTION DOCUMENTS

MILLWORK DETAILS

Author Approver

56 Forsyth Street Atlanta, Georgia

N1697519 Brandy Nabors

Elbert P Tuttle Court of Appeals Building

Nonresident Chambers Renovations

Nonresident Chambers 238 and 434

06 20 00.CT CEILING TRIM

06 41 00.DP DRAWER OR DOOR PULL

06 41 00.SS SOLID SURFACE COUNTERTOP

06 41 00.WVC WOOD VENEER CABINET

10 28 00.PTD PAPER TOWEL DISPENSER

ST

ATE OF GEORGI A

REGI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

05/06/19

A. COORDINATE CASEWORK

HARDWARE WITH SECTION 06 4100 OF

THE PROJECT MANUAL.

Revision Number

Revision Date Revision Description

A510 1 1/2" = 1'-0"

J7 FIVE DRAWERS

A510 1 1/2" = 1'-0"

J4 SINK BASE

A510 1 1/2" = 1'-0"

J1 TWO DRAWERS WITH TOWEL DISPENSER

A510 12" = 1'-0"

F1 TYP. DRAWER EDGE DETAIL

A510 12" = 1'-0"

D1 PICTURE RAIL DETAIL

A510 3" = 1'-0"

A1 TYPICAL CROWN MOLDING DETAIL

A100

E2

LAW CLKS

JUDICIAL

ADMIN

JUDGE'S

CHAMBERS

TOILET

VESTIBULE

CLOSET

247B

LAW CLK

LAW CLK

LIBRARY

JUDICIAL

ADMINISTRATOR

BREAK RM

TOILET

247A

JUDGE'S

CHAMBERS

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

GENERAL NOTES SHEET SPECIFIC NOTESMATERIAL KEYNOTES

C:\Users\Chuck\Documents\1855_Tuttle 238 434 _ 2020 _ workshared2_mtulu8RH8Z.rvt

6/3/2020 11:00:58 AM

AI100

05/28/20

CONSTRUCTION DOCUMENTS

FURNITURE AND RCP COORDINATION

Author Approver

56 Forsyth Street Atlanta, Georgia

N1697519 Brandy Nabors

Elbert P Tuttle Court of Appeals Building

Nonresident Chambers Renovations

Nonresident Chambers 238 and 434

2 41 8

ST

ATE OF GEORGI A

RE GI S T E RED A RCHI T EC

T

GREGORY WALKER

LICENSE NO. RA010

05/06/19

Revision Number

Revision Date Revision Description

AI100 3/16" = 1'-0"

A6 CH. 434 RCP AND FURNITURE COORDINATION

AI100 3/16" = 1'-0"

H3 CH. 238 RCP AND COORDINATION

C

T

HVAC LEGEND & ABBREVIATIONS

SYMBOL DESCRIPTION

RECTANGULAR AIR DUCT - FIRST DIMENSION IS SIDE SHOWN00x00

DUCT TRANSITION, RECTANGULAR TO ROUND OR OVAL

ROUND DUCT (A"∅) OR FLAT OVAL

FIRE DAMPER

AIR DUCT FLEXIBLE CONNECTOR

SUPPLY OR OUTSIDE AIR RECTANGULAR DUCT RISE OR DROP

RETURN AIR RECTANGULAR DUCT RISE OR DROPOR

OR

45° BRANCH TAKE-OFF WITH SPLITTER DAMPER AND CONTROL ROD

SINGLE BLADE DAMPER

M.D.

SMOKE DAMPER

COMBINATION FIRE/SMOKE DAMPER

SQUARE ELBOW WITH TURNING VANES

DUCT TRANSITION, RECTANGULAR TO RECTANGULAR

RADIUS ELBOW TAKE-OFF

FLEX DUCT AT DIFFUSER

DUCT-MOUNTED STATIC PRESSURE SENSOR

MANUAL VOLUME DAMPER

MD

OR

CONCENTRIC REDUCER

LINED DUCTWORK, DIMENSIONS ARE OUTER METAL TO OUTER METAL

SMOKE DETECTOR

SDT

PIPE FLOW ARROW

GRADE ARROW-INDICATES RISE OR DROP IN DUCT OR PIPEUP DNOR

CONDENSATE DRAINC

ABOVE FINISHED FLOORAFF

BOTTOM OF STRUCTUREBOS

MOTOR OPERATED DAMPERMOD

TEMPERATURE SENSOR

BACKDRAFT DAMPER

OR EXHAUST AIR RECTANGULAR DUCT RISE OR DROP

CARBON DIOXIDE SENSOR

ECCENTRIC REDUCER FLAT SIDE ON

BOTTOM OR FLAT SIDE ON TOP

MOTOR OPERATED DAMPER SAME SIZE AS

DUCT UNLESS OTHERWISE NOTED

www.houserwalker.com

A B C D E F G H J K M N P R

Nonresident Chambers Renovations

Nonresident Chambers 238 and 434

BRANDY M. NABORS

ELBERT P. TUTTLE COURT OF APPEALS BLDG

56 FORSYTH STREET NW

ATLANTA GA

GA 00088ZZ

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

GS-04P-13-BV-D-009

GS-P-04-17-EX-0073

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

SHEET OF

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

N1697519

5/22/2020 12:16:29 PM

M001

05/21/20 Construction Documents

HVAC LEGEND AND ABBREVIATIONS

GBP

TLN

1 EXISTING EQUIPMENT AND PIPING TO REMAIN, UNLESS NOTED TO BE REMOVED.

2 VERIFY LOCATIONS OF EXISTING PIPING AND EQUIPMENT PRIOR TO BEGINNING WORK.

5 PROVIDE INSULATED FLEXIBLE DUCT TO DIFFUSER SAME SIZE AS DIFFUSER NECK SIZE WITH SPIN-IN, SCOOP AND SINGLE

BLADE DAMPER AT DIFFUSER TAKE-OFF.

7 RUNOUTS TO DIFFUSERS SHALL BE SAME SIZE AS DIFFUSER NECK, UNLESS OTHERWISE NOTED.

8 ROUTE DUCTWORK AS TIGHT TO STRUCTURE AS POSSIBLE, UNLESS OTHERWISE NOTED,

9 MAXIMUM FLEXIBLE DUCT RUNOUT TO BE SEVEN FEET. USE GALVANIZED STEEL DUCT FOR INDIVIDUAL RUNOUTS OVER

SEVEN FEET.

10 BALANCE AIR DISTRIBUTION SYSTEMS AS NOTED.

11 UNLESS OTHERWISE NOTED, WALL MOUNTED THERMOSTATS AND SENSORS SHALL BE MOUNTED AT 4'-0" AFF.

12 COORDINATE ALL LAY-IN CEILING DIFFUSERS WITH ARCHITECTURAL REFLECTED CEILING PLAN.

13 PROTECT ALL MATERIALS AND EQUIPMENT FROM DAMAGE.

14 CONTRACTOR SHALL PAINT ALL DUCTWORK VISIBLE THROUGH SUPPLY AND RETURN AIR OPENINGS AND GRILLES FLAT

BLACK.

15 ALL RETURN AIR GRILLES TO BE R-1 TYPE UNLESS OTHERWISE NOTED.

16 ALL SUPPLY AIR DIFFUSERS SHALL BE TYPE S-1 UNLESS OTHERWISE NOTED.

17 ALL FLEX DUCT TO BE MECHANICALLY ATTACHED. CLAMP ONLY IS NOT SUFFICIENT. CONTRACTOR TO HAVE METHOD

APPROVED BY ENGINEER PRIOR TO INSTALLATION.

18 DUCT SIZES SHOWN ON DRAWINGS PROVIDE THE MINIMUM CROSS-SECTIONAL AREA REQUIRED. INCREASE OVERALL

DUCT DIMENSIONS AS NECESSARY TO ACCOMMODATE DUCT LINER THICKNESS.

GENERAL NOTES (APPLICABLE TO ALL HVAC SHEETS)

A

A

A.3

A.3

B

B

B.3

B.3

B.6

B.6

C

C

JUDICIAL ADMIN

8x6 10x8 14x8

18x8

"ø

VAV-4-5

JUDGE'S CHAMBERS

LAW CLKS

T

D.9

D.9

B.3

B.3

B.6

B.6

C

C

D

D

JUDICIAL

ADMINISTRATOR

LAW CLK

LAW CLK

BREAK RM

25 JUDGE'S CHAMBERS

TOILET

CLOSET

T www.houserwalker.com

A B C D E F G H J K M N P R

Nonresident Chambers Renovations

Nonresident Chambers 238 and 434

BRANDY M. NABORS

ELBERT P. TUTTLE COURT OF APPEALS BLDG

56 FORSYTH STREET NW

ATLANTA GA

GA 00088ZZ

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

GS-04P-13-BV-D-009

GS-P-04-17-EX-0073

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

SHEET OF

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

N1697519

5/22/2020 12:16:33 PM

M100

05/21/20 Construction Documents

HVAC DEMO PLAN

GBP

TLN

GENERAL NOTES KEY NOTES

EXISTING VARIABLE AIR VOLUME UNIT AND ASSOCIATED TEMPERATURE SENSOR TO BE

RELOCATED AS SHOWN ON SHEET M200. REMOVE ASSOCIATED DUCTWORK AND AIR TERMINALS.

EXISTING VARIABLE AIR VOLUME UNIT SHALL BE SHIFTED AS REQUIRED TO ACCOMODATE NEW

CEILING.

EXISTING TRANSFER AIR OPENING TO REMAIN.

EXISTING RECIRCULATION FAN TO BE REPLACED WITH NEW.

11. SEE SHEET M001 FOR HVAC GENERAL NOTES

SCALE: 3/16" = 1'-0"M100

Level 4 - HVAC Demolition Partial Plan - Chambers Suite

SCALE: 3/16" = 1'-0"M100

Level 2 - HVAC Demolition Partial Plan - Chambers Suite 238

JUDICIAL ADMIN

JUDGE'S CHAMBERS

41 LAW CLKS

A

A

A.3

A.3

B

B

B.3

B.3

B.6

B.6

C

C

VAV-4-19

VAV-4-20

T T

TEF-4-4

96x4 S-1

96x4 S-1

96x4 S-1 x4 x4

12x10

6648x46 x1

6"ø 12"ø

10"ø

28x4 16x6

D.9

D.9

B.3

B.3

B.6

B.6

C

C

D

D

JUDICIAL

ADMINISTRATOR

LAW CLK

LAW CLK

BREAK RM

JUDGE'S CHAMBERS

TOILET

CLOSET

T

T x1 x1

VAV-2-23

TEF-2-3

6"ø S-2

6"ø S-2

96x4 S-1

VAV-2-24

48x4 S-1

48x4

6 36 x4

36x4

18x12

96x4 S-1 180 14 x1 x1 x1

48x4R R-1 www.houserwalker.com

A B C D E F G H J K M N P R

Nonresident Chambers Renovations

Nonresident Chambers 238 and 434

BRANDY M. NABORS

ELBERT P. TUTTLE COURT OF APPEALS BLDG

56 FORSYTH STREET NW

ATLANTA GA

GA 00088ZZ

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

GS-04P-13-BV-D-009

GS-P-04-17-EX-0073

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

SHEET OF

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

N1697519

5/22/2020 12:16:34 PM

M200

05/21/20 Construction Documents

HVAC NEW WORK PLAN

GBP

TLN

GENERAL NOTES KEY NOTES

EXISTING VARIABLE AIR VOLUME UNIT AND ASSOCIATED TEMPERATURE SENSOR TO BE RELOCATED

AS SHOWN.

NEW TRANSFER AIR DUCT.

NEW VARIABLE VOLUME WITH ELECTRIC RE-HEAT. SEE SCHEDULES AND DETAILS FOR MORE

INFORMATION.

24"x24" ACCESS PANEL IN HARD CEILING TO PROVIDE ACCESS TO VAV CONTROL PANEL, ELECTRIC

DUCT HEATER OR FIRE DAMPER, TYPICAL.

PROVIDE NEW CEILING RECIRCULATION FAN WITH FILTER.

OUTLET LENGTH x HEIGHT VALUE FOR SUPPLY PORTION OF CONTINUOUS LINEAR DIFFUSER.

REMAINING OPENING IS FOR RETURN AIR.

OVERALL LENGTH x HEIGHT AND CFM VALUE FOR CONTINOUS LINEAR SLOT DIFFUSER.

EXISTING VAV SHALL BE RAISED AS REQUIRED TO ACCOMDATE NEW CEILING. TEMPERATURE SENSOR

TO BE RELOCATED AS SHOWN.

11. SEE SHEET M001 FOR HVAC GENERAL NOTES

2. LINEAR SLOT DIFFUSERS TO BE INSTALLED ON VERTICAL FACE OF SOFFIT.

SEE ARCHITECTURAL RCP PLAN FOR SOFFIT OUTLINE.

3. ALL FLEX DUCT TO BE MECHANICALLY ATTACHED. CLAMP ONLY IS NOT

SUFFICIENT. CONTRACTOR TO HAVE METHOD APPROVED BY ENGINEER PRIOR

TO INSTALLATION.

SCALE: 3/16" = 1'-0"M200

Level 4 - HVAC New Work Partial Plan - Chambers Suite

SCALE: 3/16" = 1'-0"M200

Level 2 - HVAC New Work Partial Plan - Chambers Suite 238

FL

OWAI

R

TYPICAL CONICAL SPIN IN FITTING WITH

DAMPER

AND STAND-OFF BRACKET.

TYPICAL FLEXIBLE

DUCTWORK (MAXIMUM

LENGTH 7 FEET.)

TYPICAL

CEILING

DIFFUSER

BRANCH DUCT

FLOW

AIR

STRAIGHT

MIN.

2'-0"HANG UNIT WITH RUBBER IN SHEAR

ISOLATORS AND THREADED RODS.

FLEX CONNECTOR.

ELECTRIC REHEAT COIL.

USE FOR ALL DUCT 90° TAPS AT MEDIUM PRESSURE RECTANGULAR DUCT.

AI

R

FL

OW

45°

*W

DD

RE

CT

AN

GU

LA

R

MA

IN

D

UC

T

1" FLANGE ALL SIDES AND ATTACH WITH #10

SHEET METAL SCREWS 4" O.C. AND DUCT

SEALER ALL SIDES *W=1/4D (MIN 6")

HEIGHT (H) = DIAMETER (D)

ROUND

BRANCH

USE FOR ALL DUCT 45° TAPS AT MEDIUM PRESSURE RECTANGULAR DUCT.

1.7 5 X

D

AIR

FLO

W

2 x D

D

ROUND

BRANCH

45°

HEIGHT (H) = DIAMETER (D)

1" FLANGE ALL SIDES AND

ATTACH WITH #10 SHEET

METAL SCREWS 4" O.C. ALL SIDES AND DUCT

SEALER

RECTANGULA

R MAIN DUCT

SEAL ALL JOINTS AND

SEAMS, AS SPECIFIED

SIZE OF CONNECTING

DUCT PLUS 2"

CEILING

ALTERNATE CONNECTION LOCATION

FOR EXHAUST DUCT RUNOUT.

TYPE R-2

EXHAUST GRILLE

PROVIDE EXHAUST DUCT

RUNOUT TO PLENUM, SIZE AS

NOTED.

PROVIDE PLENUM, FULL-

SIZE OF GRILLE DUCT

COLLAR CONNECTIONS POSITION MOTOR IN

ACCESSIBLE POSITION OR AS

INDICATED ON DRAWINGS

MOUNTED BRACKET (TYP)

FLEXIBLE CONNECTION (TYP)

THREADED STEEL RODS FROM

BUILDING STRUCTURE

TYPE 5 ISOLATORS

MOTOR GUARD

DUCT

TRANSITION (AS

REQUIRED)

DUCTDUCT

OPEN END

CEILING

DUCT ABOVE

MINIMUM LENGTH IS

1.5 x DUCT WIDTH

TRANSFER DUCT, SIZE

LINED RETURN AIR

(LINER TO LINER) AS

NOTED ON DWG.

INTERIOR WALL

DUCT WIDTH

OPEN END

ADJACENT CEILING

DUCT ABOVE

www.houserwalker.com

A B C D E F G H J K M N P R

Nonresident Chambers Renovations

Nonresident Chambers 238 and 434

BRANDY M. NABORS

ELBERT P. TUTTLE COURT OF APPEALS BLDG

56 FORSYTH STREET NW

ATLANTA GA

GA 00088ZZ

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

GS-04P-13-BV-D-009

GS-P-04-17-EX-0073

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

SHEET OF

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA, GA 30309

T. 4 0 4 . 6 3 3 . 4 2 6 4

F. 4 0 4 . 8 7 0 . 7 3 3 7 www.houserwalker.com

A B C D E F G H J K M N P R

N1697519

5/22/2020 12:16:39 PM

M400

05/21/20 Construction Documents

HVAC DETAILS

GBP

TLN

SCALE: NO SCALEM400

3 FLEXIBLE DUCT TAKE-OFF DETAIL

SCALE: NO SCALEM400

VARIABLE VOLUME TERMINAL UNIT

WITH ELECTRIC RE-HEAT

SCALE: NO SCALEM400

90° ROUND/RECTANGULAR

DUCT TAP (PLAN VIEW)

SCALE: NO SCALEM400

45° ROUND/RECTANGULAR

DUCT TAP (PLAN VIEW)

SCALE: NO SCALEM400

5 EXHAUST GRILLE DETAIL

SCALE: NO SCALEM400

6 IN-LINE FAN DETAIL

SCALE: NO SCALEM400

7 TRANSFER AIR "U" DUCT DETAIL

VAV/PIU TERMINALS POINTS LIST

VARIABLE VOLUME TERMINAL UNIT SCHEMATIC

HEATING/COOLING AUTOCHANGEOVER SEQUENCE

AIR TEMP

SUPPLY

PRIMARY AIR VALVE

CEILING

CEILING DIFFUSER

C

H

ZN- TEMP

AIR

RETURN

CEILING RETURN GRILLE

ELECTRIC REHEAT

COIL

MAX. HEATING SUPPLY TEMP.

(+15°F ABOVE SETPOINT)

AIRFLOW

SUPPLY

TEMPERATURE

HEATING

SETPOINT

COOLING

SETPOINT

HEATING MAXIMUM

AIRFLOW (APPROX. 50%

OF COOLING MAXIMUM)

DEADBAND

COOLING SUPPLY TEMP.

(APPROX. 55°F)

COOLING MAXIMUM

AIRFLOW

1ST

STAGE

HEATING

2ND

STAGE

HEATING

SUPPLY

AIR

85°F

NOTES

INPUTS

DIGITAL ANALOG

HU

MI

DI

TY

PO

W

ER

(A

MP

S/

KW

/K

W H)

MO

TO

R

CU

RR

EN

T

CO

2 L

EV

EL

(P

PM

ST

AT

IC

P

RE

SS

UR

E

AI

RF

LO

W

(C

FM

ON

/O

FF

OP

EN

/C

LO

SE

C

ON

TA

CT

AL

AR

M

CO

NT

AC

T

TE

MP

ER

AT

UR

E

SOFTWARE

ANALOG

OUTPUTS

DIGITAL

DD

C

MO

DU

LA

TI

ON

DI

FF

. P

RE

SS

. S

W

IT

CH

SE

TP

OI

NT

A

DJ

US

T

OC

CU

PI

ED

/U

NO

CC

UP

IE

D

OP

EN

/C

LO

SE

EN

AB

LE

/D

IS

AB

LE

ST

AR

T/

ST

OP

CU

RR

EN

T

SW

IT

CH

HI

/LO

LI

MI

T

ST

AT

US

A

LA

RM

TE

MP

ER

AT

UR

E

CO

NT

RO

L

RU

N

TI

ME

TR

EN

D

LO

GG

IN

G

OP

TI

MU

M

ST

AR

T

ENERGY MANAGEMENTALARM

OV

ER

RI

DE

P

RO

GR

AM

TI

ME

S

CH

ED

UL

E/

SE

TB

AC

K

PRIMARY AIR VALVE

VARIABLE AIR VOLUME TERMINAL UNITS X

X X

SPACE TEMPERATURE

UNOCCUPIED SETBACK OPERATION

SUPPLY TEMPERATURE

ELECTRIC REHEAT COIL

X

X

X

X

X XXXX

M-500 NO SCALE

M-500 NO SCALE

CONTROL SEQUENCES

A. VARIABLE AIR VOLUME TERMINAL UNITS:

a. Units shall be enabled/disabled by the DDC system based on a time schedule.

b. Units shall provide airflows as scheduled.

c. Units shall modulate airflow based on room temperature sensors to maintain a cooling setpoint of 75°F (adjustable).

d. Upon a drop in temperature below 70°F (adjustable) as sensed by the space temperature sensor, the primary air valve shall modulate to its maximum position as scheduled and the electric heater shall stage to maintain the setpoint temperature.

e. Supply air temperature shall be monitored by the DDC system.

f. Primary airflow shall be monitored by the DDC system.

g. During Unoccupied hours, the cooling setpoint shall be 80°F (adjustable) and 55°F (adjustable) for heating if applicable.

B. EXHAUST FAN CONTROL:

a. All exhaust fans serving single user restrooms shall be interlocked with light switch in corresponding room.

SCALE:

SCALE:

INPUT/

OUTPUT

SUMMARY

EXHAUST FANS X

www.houserwalker.com

A B C D E F G H J K M N P R

Nonresident Chambers Renovations

Nonresident Chambers 238 and 434

BRANDY M. NABORS

ELBERT P. TUTTLE COURT OF APPEALS BLDG

56 FORSYTH STREET NW

ATLANTA GA

GA 00088ZZ

XX0000XX XX0000XX XX0000XX

XX0000XX XX0000XX XX0000XX

XXXX

HOUSER WALKER ARCHITECTURE, LLC.

GS-04P-13-BV-D-009

GS-P-04-17-EX-0073

C

ER

TIF

IC

AT

IO

NS

KE

Y

PL

AN

RE

VI

SIO

N

NO

TE

S

SHEET SIZE:

SHEET OF

DISCIPLINE SHEET NUMBER

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

O

JE

C

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

C O

NT

RA

C

TO

RS

MARK DATE DESCRIPTION

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

22 X 34

GENERAL SERVICES ADMINISTRATION

Region 4 (Southeast - Sunbelt) 77 Forsyth Street Suite # G40 Atlanta, GA 30303

VALID ONLY FOR 22" x 34" SHEET SIZE.

WRITTEN SCALES AT DRAWING TITLE(S) ARE

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

H O U S E R W A L K E R A R C H I T E C T U R E

1819 PEACHTREE ROAD, NE

SUITE 102

ATLANTA,…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .