S02 Site Construction Layout Install Backflow B911.pdf

PDF 7 MB Posted

Attached to
Z1DA--36C26125R0047 | 36C261-25-AP-2824 | NRM 612A4-25-050 | Install Backflow Prevention Device MCC Bldg. 911
Solicitation number
36C26125R0047
Issued by

About this file

This is a site plan and construction documentation for installing a backflow prevention device at the McClellan VA Clinic in Mather, California. The project involves replacing existing water infrastructure components, including a Pressure Isolation Valve (PIV), domestic water (DW) and fire water (FW) valves, and installing a new backflow preventer. The site plans include detailed site layouts, Google Earth imagery, and actual photographs documenting the current infrastructure.

The federal contract opportunity (Solicitation Number 36C26125R0047) is a Request for Proposal issued by the Department of Veterans Affairs Veterans Health Administration, seeking a contractor to install the fire protection backflow prevention device at Building 911, located at 5443 Dudley Boulevard, McClellan, CA 95652. The proposal is due by 10:00 AM PST on June 12, 2025. Contractors must provide all necessary personnel, equipment, and expertise to complete the installation in compliance with local, state, and federal standards, specifically meeting Sacramento Suburban Water District regulatory requirements.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUILDING 911 SITE PLAN, McClellan VA Clinic, Mather CA

BUILDING 911 SITE PLAN, McClellan VA Clinic, Mather CA - Google Earth Image

BUILDING 911 SITE PLAN, McClellan VA Clinic, Mather CA - BUILDING Image Overlay

DW VALVE -

CONTRACTOR

SHALL VERIFY IF

THIS IS INDEED

THE DW VALVE

FW VALVE -

CONTRACTOR

SHALL VERIFY IF

THIS IS INDEED

THE FW VALVE

EXISTING PIV TO

BE REPLACED

WITH NEW ONE

BUILDING 911 SITE PLAN, McClellan VA Clinic, Mather CA - Close Up Images

FW VALVE -

CONTRACTOR

SHALL VERIFY IF

THIS IS INDEED

THE FW VALVE

DW VALVE -

CONTRACTOR

SHALL VERIFY IF

THIS IS INDEED

THE DW VALVE

FW VALVE -

CONTRACTOR

SHALL VERIFY IF

THIS IS INDEED

THE FW VALVE

DW VALVE -

CONTRACTOR

SHALL VERIFY IF

THIS IS INDEED

THE DW VALVE

EXISTING PIV TO

BE REPLACED

WITH NEW ONE

EXISTING PIV TO

BE REPLACED

WITH NEW ONE

LOCATION OF

NEW BACKFLOW

PREVENTOR

TRENCH FOR

TAMPER SWITCH

CONDUIT

EXISTING PIV TO

BE REPLACED

WITH NEW ONE

EXISTING DW

BACKFLOW

PREVENTOR TO

REMAIN

FW VALVEDW VALVE

LEGEND:

DW = DOMESTIC WATER

FW - FIRE WATER

BUILDING 911 SITE PLAN, McClellan VA Clinic, Mather CA - Actual Pictures

File details come from the government source that posted it. Updated .