S02 - ATTACHMENT 7 - Mechanical Equipment - EHRM Upgrade Chicago.pdf

PDF 32 MB Posted

Attached to
EHRM Infrastructure Upgrades West Campus – North Chicago - Construction Federal contract opportunity
Solicitation number
36C77623B0019
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document is a summary of an attachment to a federal contract solicitation. The attachment, S02 - ATTACHMENT 7 - Mechanical Equipment - EHRM Upgrade Chicago.pdf, relates to solicitation number 36C77623B0019 for EHRM Infrastructure Upgrades West Campus – North Chicago - Construction from the Department of Veterans Affairs Technology Acquisition Center Austin. The solicitation seeks construction services to upgrade mechanical equipment and infrastructure at the West Campus of the North Chicago VA medical center. It includes work on mechanical systems and requires adherence to specifications for materials and installation methods outlined in the attachment. The response due date and anticipated award date are not provided in this document.

View the file

Other files for this federal contract opportunity

Other files attached to EHRM Infrastructure Upgrades West Campus – North Chicago - Construction, newest first.
File Type Posted
36C77623B0019 0010 - EHRM N Chicago West - Conference Line_Wage Rates_52.204-27.pdf PDF
Updated Wage Rates - Lake County - 06.30.23.pdf PDF
Site Visit 2 Sign-In Sheet - 556-21-701 EHRM West Campus.pdf PDF
36C77623B0019 0009 - Note and Site Visit 2 Sign In Sheet.pdf PDF
S02 - 36C77623B0019 0008 - Extension and Additional Site Visit.pdf PDF
Revised Drawing Sheet GS007 - Item 133.pdf PDF
36C77623B0019 0007 - EHRM North Chicago (West) - Revised RFI Responses.pdf PDF
556-21-701 EHRM West PreBid RFIs 20JUN23.pdf PDF
36C77623B0019 0006 - EHRM North Chicago (West) - Technical Questions.pdf PDF
36C77623B0019 0005 - EHRM North Chicago (West) - Extension 6.26.23.pdf PDF
36C77623B0019 0004 - EHRM North Chicago (West) - Extension 3.16.23.pdf PDF
36C77623B0019 0003 - EHRM North Chicago (West) - Extension.pdf PDF
36C77623B0019 0003 - Updated Wage Rates - Lake County - 05.12.23.pdf PDF
36C77623B0019 0002 - Site Visit Sign-In Sheet - North Chicago (West).pdf PDF
West Campus Site Visit sign in sheet May 15 2023.pdf PDF
36C77623B0019 0001 - EHRM North Chicago (West) - Addendum 01.pdf PDF
Addendum 001.pdf PDF
00 01 10- Table of Contents.pdf PDF
01 35 26 Safety Requirements.pdf PDF
01 35 33 Infection Control Requirements.pdf PDF
26 05 33 Raceway and Boxes for Electrical Systems.pdf PDF
27 51 16 Public Address and Mass Notification.pdf PDF
27 05 33 Raceways and Boxes for Communication Systems.pdf PDF
27 52 23 Nurse call.pdf PDF
01 00 00 General Requirements.pdf PDF
01 33 23 Shop Drawings Product Data and Samples.pdf PDF
01 91 00 General Commissioning Requirements.pdf PDF
01 45 29 Testing Laboratory Services.pdf PDF
S02 - ATTACHMENT 5 - 01 35 33 Infection Control Requirements FHCC 15NOV22.pdf PDF
S02 - ATTACHMENT 8 - Mechanical Calculations - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 16 - Combined Drawings 6 of 6 - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 22 - Illinois Tax Memo - 1.26.2023.pdf PDF
S02 - SOLICITATION - 36C77623B0019_1 North Chicago EHRM (West Campus).pdf PDF
S02 - ATTACHMENT 1 - 556-21-701 Bid Specifications - Final.pdf PDF
S02 - ATTACHMENT 2 - Chicago EHRM - Design Narratives.pdf PDF
S02 - ATTACHMENT 6 - Safety Requirements.pdf PDF
S02 - ATTACHMENT 11 - Combined Drawings 1 of 6 - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 14 - Combined Drawings 4 of 6 - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 17 - Brand Name Justification - Redacted.pdf PDF
S02 - ATTACHMENT 9 - ICRA Form - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 10 - 556-21-701 EHRM West Const SOW 20 DEC22.pdf PDF
S02 - ATTACHMENT 12 - Combined Drawings 2 of 6 - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 13 - Combined Drawings 3 of 6 - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 15 - Combined Drawings 5 of 6 - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 21 - Site Visit Instructions.pdf PDF
S02 - ATTACHMENT 3 - EHRM North Chicago-100 Cost Narrative.pdf PDF
S02 - ATTACHMENT 18 - Limitations on Subcontracting - Jan 2023.pdf PDF
S02 - ATTACHMENT 19 - Contractor Safety - Environmental Form.pdf PDF
S02 - ATTACHMENT 20 - Wage Rates - Lake County - 01.20.23.pdf PDF
S02 - ATTACHMENT 4 - Environmental Comb - EHRM Upgrades Chicago.pdf PDF
Show all 50

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Job Name/Location:

Date:

PO No.:

Architect: GC:

Engr: Mech:

Rep:

(Company) (Project Manager)

For: File Resubmit Approval Other

Tag #:

For a complete list of available accessories, contact your LG representative.

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

Notes:

1. See Engineering Manual for sensible and latent capacities.

2. Max. power input is rated at maximum setting value.

3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.

4. All communication cable to be minimum 18 AWG, 2-conductor, twisted, stranded, shielded and must comply with applicable local and national codes. Ensure the communication cable is properly grounded at the main outdoor unit only. Do not ground the outdoor unit to indoor units / heat recovery units communication cable at any other point.

Wiring must comply with all applicable local and national codes.

5. Power wiring is field provided and must comply with the applicable local and national codes.

6. This unit comes with a dry nitrogen charge.

7. All capacities are net with a combination ratio between 95 – 105%.

8. Must follow installation instructions in the applicable LG installation manual.

Performance:

Total Cooling Capacity (Btu/h)1

Heating Capacity (Btu/h)1

Max Power Input (W)2

L / M / H Power Input at Factory Default (W)

Electrical:

Power Supply (V/Hz/Ø) Rated Amps

208-230/60/1

Piping:

Refrigerant Liquid Line (in., O.D.)

Vapor Line (in., O.D.)

Condensate Condensate Line (in., I.D.)

Factory Installed Pump

5/8 No

Controls Features:

Optional Accessories:

Unit Data:

Refrigerant Type Refrigerant Control Sound Pressure dB(A) (H/M/L)3

Primary Filter Type Unit Net Weight (lbs.)

Unit Shipping Weight (lbs.)

R410A

EEV

Washable

Fan:

Type Quantity Motor/Drive Motor Quantity Air Flow Rate H/M/L (CFM)

Cross Flow

Brushless Digitally Controlled/Direct

• Auto changeover (Heat Recovery only)

• Auto operation

• Auto restart

• Dual thermistor control

• Dual setpoint control

• Multiple auxillary heater applications

• Timer (on/off)

• Weekly schedule

• Auto direction/ swing (up/down)

• Fan speed control

• Jet cool (fast cooling)

• Filter life display

• Child lock

• Group control

• Hot start

• Self diagnostics

• External on/off control

• Wi-Fi compatible

• Auto Fan

• Leak Detection

Wireless Remote Controller - PQWRHQ0FDB MultiSITE™ CRC1 Controller - PREMTBVC0 MultiSITE™ CRC1+ Controller - PREMTBVC1 Simple Remote Controller - PREMTC00U Premium Remote Controller - PREMTA000 Remote Temperature Button Sensor - ZRTBS01 Simple Dry Contact (1 contact, 24 VAC external power) - PDRYCB100 Dry Contact for Third Party Thermostat - PDRYCB320 Dry Contact for Economizer - PDRYCB400 Auxillary Heater Kit - PRARS1

Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.

Multi V™ Standard Wall Mounted Unit

1/2 Flare

18.5

10,900 9,600

34 / 32 / 28

1/4 Flare

SB_MultiV_Standard_Wall_Mounted_ARNU093SJA4_2020_10_26_102952

275 / 254 / 208

9 / 12 / 13

ARNU093SJA4

9,600 Btu/h Indoor Unit

24.9

0.25 http://www.ahridirectory.org

Tag No.:

Date:

PO No.:

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

Multi V™ Standard Wall Mounted Unit

SB_MultiV_Standard_Wall_Mounted_ARNU093SJA4_2020_10_26_102952

ARNU093SJA4

9,600 Btu/h Indoor Unit

PO No.:

Architect: GC:

Engr: Mech:

Rep:

(Company) (Project Manager)

For: File Resubmit Approval Other

Tag #:

For a complete list of available accessories, contact your LG representative.

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

Notes:

1. See Engineering Manual for sensible and latent capacities.

2. Max. power input is rated at maximum setting value.

3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.

4. All communication cable to be minimum 18 AWG, 2-conductor, twisted, stranded, shielded and must comply with applicable local and national codes. Ensure the communication cable is properly grounded at the main outdoor unit only. Do not ground the outdoor unit to indoor units / heat recovery units communication cable at any other point.

Wiring must comply with all applicable local and national codes.

5. Power wiring is field provided and must comply with the applicable local and national codes.

6. This unit comes with a dry nitrogen charge.

7. All capacities are net with a combination ratio between 95 – 105%.

8. Must follow installation instructions in the applicable LG installation manual.

Performance:

Total Cooling Capacity (Btu/h)1

Heating Capacity (Btu/h)1

Max Power Input (W)2

L / M / H Power Input at Factory Default (W)

Electrical:

Power Supply (V/Hz/Ø) Rated Amps

208-230/60/1

Piping:

Refrigerant Liquid Line (in., O.D.)

Vapor Line (in., O.D.)

Condensate Condensate Line (in., I.D.)

Factory Installed Pump

5/8 No

Controls Features:

Optional Accessories:

Unit Data:

Refrigerant Type Refrigerant Control Sound Pressure dB(A) (H/M/L)3

Primary Filter Type Unit Net Weight (lbs.)

Unit Shipping Weight (lbs.)

R410A

EEV

Washable

Fan:

Type Quantity Motor/Drive Motor Quantity Air Flow Rate H/M/L (CFM)

Cross Flow

Brushless Digitally Controlled/Direct

• Auto changeover (Heat Recovery only)

• Auto operation

• Auto restart

• Dual thermistor control

• Dual setpoint control

• Multiple auxillary heater applications

• Timer (on/off)

• Weekly schedule

• Auto direction/ swing (up/down)

• Fan speed control

• Jet cool (fast cooling)

• Filter life display

• Child lock

• Group control

• Hot start

• Self diagnostics

• External on/off control

• Wi-Fi compatible

• Auto Fan

• Leak Detection

Wireless Remote Controller - PQWRHQ0FDB MultiSITE™ CRC1 Controller - PREMTBVC0 MultiSITE™ CRC1+ Controller - PREMTBVC1 Simple Remote Controller - PREMTC00U Premium Remote Controller - PREMTA000 Remote Temperature Button Sensor - ZRTBS01 Simple Dry Contact (1 contact, 24 VAC external power) - PDRYCB100 Dry Contact for Third Party Thermostat - PDRYCB320 Dry Contact for Economizer - PDRYCB400 Auxillary Heater Kit - PRARS1

Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.

Multi V™ Standard Wall Mounted Unit

1/2 Flare

18.5

13,600 12,300

37 / 34 / 30

1/4 Flare

SB_MultiV_Standard_Wall_Mounted_ARNU123SJA4_2020_10_26_102952

300 / 254 /240

11 / 13 / 15

ARNU123SJA4

12,300 Btu/h Indoor Unit

24.9

Date:

PO No.:

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

Multi V™ Standard Wall Mounted Unit

SB_MultiV_Standard_Wall_Mounted_ARNU123SJA4_2020_10_26_102952

ARNU123SJA4

12,300 Btu/h Indoor Unit

PO No.:

Architect: GC:

Engr: Mech:

Rep:

(Company) (Project Manager)

For: File Resubmit Approval Other

Tag #:

For a complete list of available accessories, contact your LG representative.

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

Notes:

1. See Engineering Manual for sensible and latent capacities.

2. Max. power input is rated at maximum setting value.

3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.

4. All communication cable to be minimum 18 AWG, 2-conductor, twisted, stranded, shielded and must comply with applicable local and national codes. Ensure the communication cable is properly grounded at the main outdoor unit only. Do not ground the outdoor unit to indoor units / heat recovery units communication cable at any other point.

Wiring must comply with all applicable local and national codes.

5. Power wiring is field provided and must comply with the applicable local and national codes.

6. This unit comes with a dry nitrogen charge.

7. All capacities are net with a combination ratio between 95 – 105%.

8. Must follow installation instructions in the applicable LG installation manual.

Performance:

Total Cooling Capacity (Btu/h)1

Heating Capacity (Btu/h)1

Max Power Input (W)2

L / M / H Power Input at Factory Default (W)

Electrical:

Power Supply (V/Hz/Ø) Rated Amps

208-230/60/1

Piping:

Refrigerant Liquid Line (in., O.D.)

Vapor Line (in., O.D.)

Condensate Condensate Line (in., I.D.)

Factory Installed Pump

5/8 No

Controls Features:

Optional Accessories:

Unit Data:

Refrigerant Type Refrigerant Control Sound Pressure dB(A) (H/M/L)3

Primary Filter Type Unit Net Weight (lbs.)

Unit Shipping Weight (lbs.)

R410A

EEV

Washable

Fan:

Type Quantity Motor/Drive Motor Quantity Air Flow Rate H/M/L (CFM)

Cross Flow

Brushless Digitally Controlled/Direct

• Auto changeover (Heat Recovery only)

• Auto operation

• Auto restart

• Dual thermistor control

• Dual setpoint control

• Multiple auxillary heater applications

• Timer (on/off)

• Weekly schedule

• Auto direction/ swing (up/down)

• Fan speed control

• Jet cool (fast cooling)

• Filter life display

• Child lock

• Group control

• Hot start

• Self diagnostics

• External on/off control

• Wi-Fi compatible

• Auto Fan

• Leak Detection

Wireless Remote Controller - PQWRHQ0FDB MultiSITE™ CRC1 Controller - PREMTBVC0 MultiSITE™ CRC1+ Controller - PREMTBVC1 Simple Remote Controller - PREMTC00U Premium Remote Controller - PREMTA000 Remote Temperature Button Sensor - ZRTBS01 Simple Dry Contact (1 contact, 24 VAC external power) - PDRYCB100 Dry Contact for Third Party Thermostat - PDRYCB320 Dry Contact for Economizer - PDRYCB400 Auxillary Heater Kit - PRARS1

Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.

Multi V™ Standard Wall Mounted Unit

1/2 Flare

18.5

17,100 15,400

42 / 39 / 32

1/4 Flare

SB_MultiV_Standard_Wall_Mounted_ARNU153SJA4_2020_10_26_102953

371 / 336 / 240

11 / 18 / 23

ARNU153SJA4

15,400 Btu/h Indoor Unit

24.9

Date:

PO No.:

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

Multi V™ Standard Wall Mounted Unit

SB_MultiV_Standard_Wall_Mounted_ARNU153SJA4_2020_10_26_102953

ARNU153SJA4

15,400 Btu/h Indoor Unit

PO No.:

Architect: GC:

Engr: Mech:

Rep:

(Company) (Project Manager)

For: File Resubmit Approval Other

Tag #:

For a complete list of available accessories, contact your LG representative.

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

Notes:

1. See Engineering Manual for sensible and latent capacities.

2. Max. power input is rated at maximum setting value.

3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.

4. All communication cable to be minimum 18 AWG, 2-conductor, twisted, stranded, shielded and must comply with applicable local and national codes. Ensure the communication cable is properly grounded at the main outdoor unit only. Do not ground the outdoor unit to indoor units / heat recovery units communication cable at any other point.

Wiring must comply with all applicable local and national codes.

5. Power wiring is field provided and must comply with the applicable local and national codes.

6. This unit comes with a dry nitrogen charge.

7. All capacities are net with a combination ratio between 95 – 105%.

8. Must follow installation instructions in the applicable LG installation manual.

Performance:

Total Cooling Capacity (Btu/h)1

Heating Capacity (Btu/h)1

Max Power Input (W)2

L / M / H Power Input at Factory Default (W)

Electrical:

Power Supply (V/Hz/Ø) Rated Amps

208-230/60/1

Piping:

Refrigerant Liquid Line (in., O.D.)

Vapor Line (in., O.D.)

Condensate Condensate Line (in., I.D.)

Factory Installed Pump

5/8 No

Controls Features:

Optional Accessories:

Unit Data:

Refrigerant Type Refrigerant Control Sound Pressure dB(A) (H/M/L)3

Primary Filter Type Unit Net Weight (lbs.)

Unit Shipping Weight (lbs.)

R410A

EEV

Washable

Fan:

Type Quantity Motor/Drive Motor Quantity Air Flow Rate H/M/L (CFM)

Cross Flow

Brushless Digitally Controlled/Direct

• Auto changeover (Heat Recovery only)

• Auto operation

• Auto restart

• Dual thermistor control

• Dual setpoint control

• Multiple auxillary heater applications

• Timer (on/off)

• Weekly schedule

• Auto direction/ swing (up/down)

• Fan speed control

• Jet cool (fast cooling)

• Filter life display

• Child lock

• Group control

• Hot start

• Self diagnostics

• External on/off control

• Wi-Fi compatible

• Auto Fan

• Leak Detection

Wireless Remote Controller - PQWRHQ0FDB MultiSITE™ CRC1 Controller - PREMTBVC0 MultiSITE™ CRC1+ Controller - PREMTBVC1 Simple Remote Controller - PREMTC00U Premium Remote Controller - PREMTA000 Remote Temperature Button Sensor - ZRTBS01 Simple Dry Contact (1 contact, 24 VAC external power) - PDRYCB100 Dry Contact for Third Party Thermostat - PDRYCB320 Dry Contact for Economizer - PDRYCB400 Auxillary Heater Kit - PRARS1

Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.

Multi V™ Standard Wall Mounted Unit

1/2 Flare

26.9

21,500 19,100

43 / 39 / 34

1/4 Flare

SB_MultiV_Standard_Wall_Mounted_ARNU183SKA4_2020_10_26_102953

494 / 424 / 371

16 / 26 / 32

ARNU183SKA4

19,100 Btu/h Indoor Unit

35.3

0.52

Date:

PO No.:

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

Multi V™ Standard Wall Mounted Unit

SB_MultiV_Standard_Wall_Mounted_ARNU183SKA4_2020_10_26_102953

ARNU183SKA4

19,100 Btu/h Indoor Unit

PO No.:

Architect: GC:

Engr: Mech:

Rep:

(Company) (Project Manager)

For: File Resubmit Approval Other

Tag #:

For a complete list of available accessories, contact your LG representative.

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

Notes:

1. See Engineering Manual for sensible and latent capacities.

2. Max. power input is rated at maximum setting value.

3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.

4. All communication cable to be minimum 18 AWG, 2-conductor, twisted, stranded, shielded and must comply with applicable local and national codes. Ensure the communication cable is properly grounded at the main outdoor unit only. Do not ground the outdoor unit to indoor units / heat recovery units communication cable at any other point.

Wiring must comply with all applicable local and national codes.

5. Power wiring is field provided and must comply with the applicable local and national codes.

6. This unit comes with a dry nitrogen charge.

7. All capacities are net with a combination ratio between 95 – 105%.

8. Must follow installation instructions in the applicable LG installation manual.

Performance:

Total Cooling Capacity (Btu/h)1

Heating Capacity (Btu/h)1

Max Power Input (W)2

L / M / H Power Input at Factory Default (W)

Electrical:

Power Supply (V/Hz/Ø) Rated Amps

208-230/60/1

Piping:

Refrigerant Liquid Line (in., O.D.)

Vapor Line (in., O.D.)

Condensate Condensate Line (in., I.D.)

Factory Installed Pump

5/8 No

Controls Features:

Optional Accessories:

Unit Data:

Refrigerant Type Refrigerant Control Sound Pressure dB(A) (H/M/L)3

Primary Filter Type Unit Net Weight (lbs.)

Unit Shipping Weight (lbs.)

R410A

EEV

Washable

Fan:

Type Quantity Motor/Drive Motor Quantity Air Flow Rate H/M/L (CFM)

Cross Flow

Brushless Digitally Controlled/Direct

• Auto changeover (Heat Recovery only)

• Auto operation

• Auto restart

• Dual thermistor control

• Dual setpoint control

• Multiple auxillary heater applications

• Timer (on/off)

• Weekly schedule

• Auto direction/ swing (up/down)

• Fan speed control

• Jet cool (fast cooling)

• Filter life display

• Child lock

• Group control

• Hot start

• Self diagnostics

• External on/off control

• Wi-Fi compatible

• Auto Fan

• Leak Detection

Wireless Remote Controller - PQWRHQ0FDB MultiSITE™ CRC1 Controller - PREMTBVC0 MultiSITE™ CRC1+ Controller - PREMTBVC1 Simple Remote Controller - PREMTC00U Premium Remote Controller - PREMTA000 Remote Temperature Button Sensor - ZRTBS01 Simple Dry Contact (1 contact, 24 VAC external power) - PDRYCB100 Dry Contact for Third Party Thermostat - PDRYCB320 Dry Contact for Economizer - PDRYCB400 Auxillary Heater Kit - PRARS1

Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.

Multi V™ Standard Wall Mounted Unit

5/8 Flare

26.9

25,600 24,200

46 / 41 / 34

3/8 Flare

SB_MultiV_Standard_Wall_Mounted_ARNU243SKA4_2020_10_26_102953

537 / 449 /371

16 / 26 / 39

ARNU243SKA4

24,200 Btu/h Indoor Unit

35.3

0.52

Date:

PO No.:

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

Multi V™ Standard Wall Mounted Unit

SB_MultiV_Standard_Wall_Mounted_ARNU243SKA4_2020_10_26_102953

ARNU243SKA4

24,200 Btu/h Indoor Unit

� Low Ambient Wind Baffle (Cooling operation to 0°F) ‐ ZLABGP04A

� Simple Remote Controller ‐ PREMTC00U �Premium Remote Controller ‐ PREMTA000 �MultiSITE™ CRC1 ‐ PREMTBVC0 �MultiSITE CRC1+ ‐ PREMTBVC1

�MultiSITE Comm. Mgr. ‐ PBACNBTR0A

� PI‐485 ‐ PMNFP14A1

� Dry Contact ‐ PDRYCB100/300/400 � AC Smart 5 ‐ PACS5A000

� ACP 5 ‐ PACP5A000

Job Name/Location:

Date:

PO No.:

Architect: GC:

Engr: Mech:

Rep:

(Company) (Project Manager)

For: File Resubmit Approval Other

Tag No.:

For a complete list of available accessories, contact your LG representative.

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

1. Acceptable operating voltage: 187V‐253V.

2. Piping lengths are equivalent.

3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.

4. All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied and must be a minimum of four‐conductor, 14 AWG, stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes.

5. See Engineering Manual for sensible and latent capacities.

6. Power wiring cable size must comply with the applicable local and national code.

7. The indoor unit comes with a dry helium charge.

8. This data is rated 0 ft. above sea level, with 24.6 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor units.

9. Must follow installation instructions in the applicable LG installation manual.

Notes:

Performance:

Cooling:

Cooling Capacity (Min~Rated~Max) (Btu/h)

SEER

EER

Heating:

Cooling Nominal Test Conditions:

Indoor: 80°F DB / 67°F WB Outdoor: 95°F DB / 75°F WB

Heating Nominal Test Conditions:

Indoor: 70°F DB / 60°F WB Outdoor: 47°F DB / 43°F WB

Heating Capacity (Min~Rated~Max) (Btu/h)

HSPF

Max. Heating @ Indoor 70°F DB Outdoor 19°F DB / 17°F WB Outdoor 6°F DB / 5°F WB Outdoor ‐3°F DB / ‐4°F WB

SEER ‐ Seasonal Energy Efficiency Ratio EER ‐ Energy Efficiency Ratio

HSPF ‐ Heating Seasonal Performance Factor

Electrical:

Power Supply (V¹/Hz/Ø) 208‐230/60/1

Outdoor Unit:

MOP (A)

MCA (A)

Cooling / Heating Rated Amps (A) Compressor (A) Fan Motor (A)

MOP ‐ Maximum Overcurrent Protection MCA ‐ Minimum Circuit Ampacity

Total Power Input:

Cooling Power Input (kW) Heating Power Input (kW)

Piping:

Liquid Line (in., O.D.)

Vapor Line (in., O.D.)

Additional Refrigerant (oz./ft.)

Min. / Max. Pipe Length (ft.)² Piping Length (no add’l refrig., ft.)

Max. Elevation (ft.)

�3/8 Flare �5/8 Flare

0.38

9.8 / 164

24.6 98.4

Features:

• 24‐Hour on/off timer

• 4‐Way auto swing

• Auto changeover

• Auto restart

• Jet cool/Jet heat

• Built‐in low ambient standard, down to 14°F (cooling mode)

• Condensate Sensor Connection

• Inverter (variable speed compressor)

• Smart Diagnosis

• Washable Filter

• Self‐cleaning indoor coil

• Built‐in base pan heater

• Built‐in Wi‐Fi via Smart ThinQ app

Optional Accessories:

Cooling (°F DB) Heating (°F WB)

14 ~ 118 ‐4 ~ +65

Operating Range:

Outdoor Unit:

Indoor Unit:

Cooling (°F WB) Heating (°F DB)

53 ~ 75 64 ~ 86

System Data:

Refrigerant Type Refrigerant Control Refrigerant Charge (lbs.)

ODU Sound Pressure (Cooling / Heating) (±1 dB[A])³ IDU Sound Pressure Cooling (H/M/L/Sleep) (±1 dB[A])³ Heating (H/M/L) (±1 dB[A])³ ODU Net / Shipping Weight (lbs.)

IDU Net / Shipping Weight (lbs.)

Heat Exchanger Coating

R410A

EEV

GoldFin™

Fan:

ODU Type IDU Type Fan Speeds (Fan/Cool/Heat) Quantity (ODU + IDU) Motor/Drive ODU Max. Air Flow Rate (CFM) IDU Air Flow Cooling, Max/H/M/L (CFM) Heating, Max/H/M/L (CFM) Dehumidification (pts./hr.)

Propeller Cross Flow

6 / 6 / 6 1 + 1

Brushless Digitally Controlled/Direct

21,170 (81%)

3,070~26,000~36,200

27,360 (105%)

4.85

55 / 56

1.69

14.81

135.4 / 147.7

36.6 / 44.5

0.4

LS243HLV3

21.5

2,119

Single Zone Extended Piping Wall Mount

4.65

Outdoor Unit (ODU) - LSU243HLV3, Indoor Unit (IDU) - LSN243HLV3

3,070~22,000~30,000

49 / 44 / 40

2.08

14.41

23,700 (91%)

49 / 44 / 40 / 30

919 / 707 / 601 / 495

SB_SZ_WM_ExtendedPiping_LS243HLV3_2020_03_17_140319

813 / 601 / 495 / 389

Date:

PO No.:

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com Page 2 of 3

LS243HLV3

Single Zone Extended Piping Wall Mount Outdoor Unit (ODU) - LSU243HLV3, Indoor Unit (IDU) - LSN243HLV3

Date:

PO No.:

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com Page 3 of 3

LS243HLV3

Single Zone Extended Piping Wall Mount Outdoor Unit (ODU) - LSU243HLV3, Indoor Unit (IDU) - LSN243HLV3

Mounting Options After an installation area for the outdoor unit(s) is chosen, verify:

• The floor surface / chosen location has enough strength to support the weight of the unit(s) and base.

• There is enough space for piping and wiring (when installed through the bottom of the unit).

• There is sufficient slope for proper drainage away and between the units from the condensate drain connection(s) to the floor drain (if present).

• Run-off from defrost mode will not accumulate and freeze on sidewalks or driveways.

• Avoid placing the unit(s) in a low-lying area where water may accumulate.

• If Installing the outdoor unit on a roof, check the strength of the roof.

All four corners, as well as the center of the outdoor unit, must be supported properly. All four corners of the outdoor unit must be securely fastened to a:

• Supporting base.

• Concrete pad.

• Base rails.

• Mounting platform that is anchored to the building.

• Any acceptable support structure that is designed by a structural engineer.

Do not support the outdoor unit only by the corners.

Refer to the dimensional drawings of the unit(s), and always follow the applicable local and state codes for clearances, mounting, anchor, and vibration attenuation requirements.

• The outdoor unit supports must have a minimum height of 7-7/8 inches, and a minimum width of four (4) inches under the unit’s legs before being attached.

• Anchor bolts must be installed at least three (3) inches into the support.

• Include anti-vibration material chosen by the acous-tics engineer.

• Use a hexagon nut with a spring washer.

• I-Beams can be used as a base support.

At least 4 Inches

Center of the Unit Center of the Unit At least 4 Inches At least 4 Inches

At least 4 Inches

At least 4 Inches

At least 4 Inches

Outdoor Unit Mounting Methods.

Mounting Requirements and Options.

Nut

3"

Spring Washer Frame

Anti-Vibration Materials

Minimum Three (3) Thread Ridges I-Beam

Concrete Base Anti-Vibration

Materials

3"Anchor Bolt

Anchor Bolt

Concrete Base

7-7/8" 3-15/16"

7-7/8"

Tools

• Screw Drivers (JIS for terminal screws, Flat, Phillips)

• Pliers

• Wire Strippers, Cutters, and

Crimpers

• Hammer

• Adjustable Wrenches

• Drill and Bits

• Hole Saw

• Utility Knife

• Drop Cloth

• Pipe Cutter / Reamer

• Acetylene Brazing Outfit

• Brazing Material —15% silver only

• Digital Multimeter and Amp

Clamp

• R-410A Flaring Tool

• Torque Wrench Set

• Dedicated R-410A Refrigerant

Manifold Gauge

• Dedicated 5/16" Premium Hoses

• Nitrogen regulator (for 550# test)

• 1/4" to 5/16" Hose Adapters (if needed)

• Nitrogen Tank

• Electronic Leak Detector

• 5/16" Schrader Core Removal

Tool

• Vacuum Micron Gauge

• Good Quality Digital Charging

Scale

• Vacuum Pump and Fresh Oil

• Refrigerant Recovery Unit and

Tank

Verify the tools listed below are available for use at the installation site:

At least 7-7/8 Inches

Concrete Support I-Beam Support

Space for Bottom Install Wiring and Piping

Anti-Vibration Materials Between the Outdoor Unit and Support

WARNING

Outdoor Unit Mounting Bolt / Foundation• Install the outdoor unit to protect against extremely high winds and earthquakes. Any deficiency in installation may cause unit to fall, re-sulting in physical injury or death.

• The corners of the outdoor unit must be attached firmly to the support, otherwise, the bolts may bend, cause the outdoor unit to fall, which may result in physical injury or death.

• Attach the bolts tightly to ensure the outdoor unit will not fall due to earthquakes or strong wind gusts, causing physical injury or death.

• If the floor surface / chosen location is not strong enough to support the weight, the unit will fall and cause physical injury or death.

Anchoring the Outdoor Unit

Piping Piping Selection ACR-rated, seamless phosphorous deoxidized copper (UNS C12200 DHP class) is the only approved refrigerant pipe material for LG Multi V S products. Approved piping will be marked “R-410A rated” along the length of the tube.

• Drawn temper (rigid) ACR copper tubing is available in sizes 3/8 through 2-1/8 inches (ASTM B 280, clean, dry and capped).

• Annealed temper (soft) ACR copper tubing is available in sizes 1/4 through 2-1/8 inches (ASTM B 280, clean, dry, and capped).

• Wall thickness must meet local code requirements and be approved for a maximum operating pressure of 551 psi.

• LG recommends soft copper use to be limited to 1/2 inches. Use hard drawn for larger sizes to avoid sags and kinks that lead to oil trapping.

Outdoor Unit Mounting Options.

Job Name/Location

PO No.:

Architect: GC:

Engr: Mech:

Rep:

(Company) (Project Manager)

Tag #:

• Night Quiet Operation

• Fault Detection and Diagnosis

Standard Features:

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

1. For AHRI rating, refer to the AHRI website http://www.ahridirectory.org.

2. The combination ratio must be between 50 – 130%.

3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard

3745.

4. Communication cable between ODU, IDU(s), and Central Controller must be a minimum of 2‐conductor, 18 AWG, twisted, stranded, and shielded. Ensure the communication cable shield is properly grounded to the ODU chassis only. Do not ground the communication cable at any other point. Wiring must comply with all applicable local and national codes.

5. Nominal data is rated 0 ft above sea level, with 25 ft of refrigerant line per indoor unit and a 0 ft level difference between outdoor and indoor units. All capacities are net with a combination ratio between 95‐105%.

6. Power wiring cable size must comply with the applicable local and national codes.

7. The voltage tolerance is ± 10%.

Notes:

Optional Accessories:

For: File Resubmit Approval Other

Performance:

Cooling Mode:

Rated Capacity (Btu/h) Power Input1 (kW)

Heating Mode:

Rated Capacity (Btu/h) Power Input1 (kW)

Rated Capacity is based on the following conditions:

Cooling Indoor: 80°F DB / 67°F WB Outdoor: 95°F DB

Heating:

Indoor: 70°F DB Outdoor: 47°F DB / 43°F WB

Electrical:

Power Supply (V/Hz/Ø)

MOP (A)

MCA (A)

Rated Amps (A)

Compressor (A) Fan (A) x Qty.

208‐230V / 60 / 1

Refrigerant Charge (lbs) Liquid Line (in, OD) Vapor Line (in, OD)

Piping:

*Installation of an optional Low Ambient Wind Baffle Kit will allow operation down to ‐9.9°F in cooling mode.

Cooling (°F DB)* Heating (°F WB)

23 ‐ 122

Operating Range:

Refrigerant Type Refrigerant Control Max Number of Indoor Units2

Sound Pressure3 dB(A) Net Unit Weight (lbs) Shipping Weight (lbs) Communication Cable4 (No x AWG) Heat Exchanger Coating

R410A

EEV

2 x 18 GoldFin™

Unit Data:

Type Quantity Oil / Type

PVE/FVC68D

Compressor:

Type Quantity Motor / Drive Air Flow Rate (CFM)

Brushless Digitally Controlled/Direct

Fan:

Multi V™ S Heat Pump

Ø5/8 Flare

-4 to +61

1.52

27,000

0.5 x 1

Low Ambient Baffle Kit ‐ ZLABGP04A (1 required)

19.6

24,000

2,119

SB_MultiV_S_HP_ARUN024GSS4_2020_07_21_131516

DC Inverter Starting

Axial Flow Fan

2.02

2.0 Ton Outdoor Unit

15.3

ARUN024GSS4

Ø3/8 Flare

Drain Pan Heater ‐ PQSH1200

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com Page 2 of 3

Job Name/Location:

Tag No.:

Date:

PO No.:Multi V™ S Heat Pump

SB_MultiV_S_HP_ARUN024GSS4_2020_07_21_131516

2.0 Ton Outdoor Unit

ARUN024GSS4

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com Page 3 of 3

Job Name/Location:

Tag No.:

Date:

PO No.:

AHRI Certified Reference Number

Indoor Type

AHRI Certified Ratings ‐

Cooling Capacity (95°F)

AHRI Certified Ratings ‐ EER

(95°F)

AHRI Certified Ratings ‐ SEER

AHRI Certified Ratings ‐ High

Heating Capacity (47°F)

AHRI Certified Ratings ‐ Low

Heating Capacity (17°F)

AHRI Certified Ratings ‐ HSPF

Non‐Ducted Indoor Units

Ducted Indoor Units

Mixed Ducted and Non‐Ducted Indoor Units

AHRI Data:

27,000

Multi V™ S Heat Pump

16.40

10070563 17,000

10.00

27,000

27,000

18,00017.0010070562

17,50010271658 24,000 11.45

24,000

SB_MultiV_S_HP_ARUN024GSS4_2020_07_21_131516

9.30

24,000

2.0 Ton Outdoor Unit

ARUN024GSS4

8.6012.20 15.80

10.70

PO No.:

Architect: GC:

Engr: Mech:

Rep:

(Company) (Project Manager)

Tag #:

• Night Quiet Operation

• Fault Detection and Diagnosis

Standard Features:

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

1. For AHRI rating, refer to the AHRI website http://www.ahridirectory.org.

2. The combination ratio must be between 50 – 130%.

3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard

3745.

4. Communication cable between ODU, IDU(s), and Central Controller must be a minimum of 2‐conductor, 18 AWG, twisted, stranded, and shielded. Ensure the communication cable shield is properly grounded to the ODU chassis only. Do not ground the communication cable at any other point. Wiring must comply with all applicable local and national codes.

5. Nominal data is rated 0 ft above sea level, with 25 ft of refrigerant line per indoor unit and a 0 ft level difference between outdoor and indoor units. All capacities are net with a combination ratio between 95‐105%.

6. Power wiring cable size must comply with the applicable local and national codes.

7. The voltage tolerance is ± 10%.

Notes:

Optional Accessories:

For: File Resubmit Approval Other

Performance:

Cooling Mode:

Rated Capacity (Btu/h) Power Input1 (kW)

Heating Mode:

Rated Capacity (Btu/h) Power Input1 (kW)

Rated Capacity is based on the following conditions:

Cooling Indoor: 80°F DB / 67°F WB Outdoor: 95°F DB

Heating:

Indoor: 70°F DB Outdoor: 47°F DB / 43°F WB

Electrical:

Power Supply (V/Hz/Ø)

MOP (A)

MCA (A)

Rated Amps (A)

Compressor (A) Fan (A) x Qty.

208‐230V / 60 / 1

Refrigerant Charge (lbs) Liquid Line (in, OD) Vapor Line (in, OD)

Piping:

*Installation of an optional Low Ambient Wind Baffle Kit will allow operation down to ‐9.9°F in cooling mode.

Cooling (°F DB)* Heating (°F WB)

23 ‐ 122

Operating Range:

Refrigerant Type Refrigerant Control Max Number of Indoor Units2

Sound Pressure3 dB(A) Net Unit Weight (lbs) Shipping Weight (lbs) Communication Cable4 (No x AWG) Heat Exchanger Coating

R410A

EEV

2 x 18 GoldFin™

Unit Data:

Type Quantity Oil / Type

PVE/FVC68D

Compressor:

Type Quantity Motor / Drive Air Flow Rate (CFM)

Brushless Digitally Controlled/Direct

Fan:

Multi V™ S Heat Pump

Ø5/8 Braze

-4 to +61

2.77

6.6

42,000

0.5 x 2

Low Ambient Baffle Kit ‐ ZLABGP04A (2 required)

38,000

3,885

SB_MultiV_S_HP_ARUN038GSS4_2020_07_21_131516

DC Inverter Starting

Axial Flow Fan

3.22

3.0 Ton Outdoor Unit

19.5

ARUN038GSS4

Ø3/8 Braze

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com Page 2 of 3

Job Name/Location:

Tag No.:

Date:

PO No.:Multi V™ S Heat Pump

SB_MultiV_S_HP_ARUN038GSS4_2020_07_21_131516

3.0 Ton Outdoor Unit

ARUN038GSS4

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com Page 3 of 3

Job Name/Location:

Tag No.:

Date:

PO No.:

AHRI Certified Reference Number

Indoor Type

AHRI Certified Ratings ‐

Cooling Capacity (95°F)

AHRI Certified Ratings ‐ EER

(95°F)

AHRI Certified Ratings ‐ SEER

AHRI Certified Ratings ‐ High

Heating Capacity (47°F)

AHRI Certified Ratings ‐ Low

Heating Capacity (17°F)

AHRI Certified Ratings ‐ HSPF

Non‐Ducted Indoor Units

Ducted Indoor Units

Mixed Ducted and Non‐Ducted Indoor Units

AHRI Data:

42,000

Multi V™ S Heat Pump

17.00

8717932 26,000

9.00

42,000

42,000

26,00017.008717931

26,0008717933 38,000 11.50

38,000

SB_MultiV_S_HP_ARUN038GSS4_2020_07_21_131516

9.00

38,000

3.0 Ton Outdoor Unit

ARUN038GSS4

9.0011.50 17.00

11.50

PO No.:

Architect: GC:

Engr: Mech:

Rep:

(Company) (Project Manager)

Tag #:

• Night Quiet Operation

• Fault Detection and Diagnosis

Standard Features:

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

1. For AHRI rating, refer to the AHRI website http://www.ahridirectory.org.

2. The combination ratio must be between 50 – 130%.

3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard

3745.

4. Communication cable between ODU, IDU(s), and Central Controller must be a minimum of 2‐conductor, 18 AWG, twisted, stranded, and shielded. Ensure the communication cable shield is properly grounded to the ODU chassis only. Do not ground the communication cable at any other point. Wiring must comply with all applicable local and national codes.

5. Nominal data is rated 0 ft above sea level, with 25 ft of refrigerant line per indoor unit and a 0 ft level difference between outdoor and indoor units. All capacities are net with a combination ratio between 95‐105%.

6. Power wiring cable size must comply with the applicable local and national codes.

7. The voltage tolerance is ± 10%.

Notes:

Optional Accessories:

For: File Resubmit Approval Other

Performance:

Cooling Mode:

Rated Capacity (Btu/h) Power Input1 (kW)

Heating Mode:

Rated Capacity (Btu/h) Power Input1 (kW)

Rated Capacity is based on the following conditions:

Cooling Indoor: 80°F DB / 67°F WB Outdoor: 95°F DB

Heating:

Indoor: 70°F DB Outdoor: 47°F DB / 43°F WB

Electrical:

Power Supply (V/Hz/Ø)

MOP (A)

MCA (A)

Rated Amps (A)

Compressor (A) Fan (A) x Qty.

208‐230V / 60 / 1

Refrigerant Charge (lbs) Liquid Line (in, OD) Vapor Line (in, OD)

Piping:

*Installation of an optional Low Ambient Wind Baffle Kit will allow operation down to ‐9.9°F in cooling mode.

Cooling (°F DB)* Heating (°F WB)

23 ‐ 122

Operating Range:

Refrigerant Type Refrigerant Control Max Number of Indoor Units2

Sound Pressure3 dB(A) Net Unit Weight (lbs) Shipping Weight (lbs) Communication Cable4 (No x AWG) Heat Exchanger Coating

R410A

EEV

2 x 18 GoldFin™

Unit Data:

Type Quantity Oil / Type

PVE/FVC68D

Compressor:

Type Quantity Motor / Drive Air Flow Rate (CFM)

Brushless Digitally Controlled/Direct

Fan:

Multi V™ S Heat Pump

Ø5/8 Braze

-4 to +61

4.3

6.6

54,000

0.5 x 2

Low Ambient Baffle Kit ‐ ZLABGP04A (2 required)

48,000

3,885

SB_MultiV_S_HP_ARUN048GSS4_2020_07_21_131517

DC Inverter Starting

Axial Flow Fan

4.2

4.0 Ton Outdoor Unit

23.1

ARUN048GSS4

Ø3/8 Braze

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com Page 2 of 3

Job Name/Location:

Tag No.:

Date:

PO No.:Multi V™ S Heat Pump

SB_MultiV_S_HP_ARUN048GSS4_2020_07_21_131517

4.0 Ton Outdoor Unit

ARUN048GSS4

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com Page 3 of 3

Job Name/Location:

Tag No.:

Date:

PO No.:

AHRI Certified Reference Number

Indoor Type

AHRI Certified Ratings ‐

Cooling Capacity (95°F)

AHRI Certified Ratings ‐ EER

(95°F)

AHRI Certified Ratings ‐ SEER

AHRI Certified Ratings ‐ High

Heating Capacity (47°F)

AHRI Certified Ratings ‐ Low

Heating Capacity (17°F)

AHRI Certified Ratings ‐ HSPF

Non‐Ducted Indoor Units

Ducted Indoor Units

Mixed Ducted and Non‐Ducted Indoor Units

AHRI Data:

54,000

Multi V™ S Heat Pump

17.00

8717930 32,000

9.50

54,000

54,000

32,00017.008717929

32,0008717934 48,000 10.50

48,000

SB_MultiV_S_HP_ARUN048GSS4_2020_07_21_131517

9.50

48,000

4.0 Ton Outdoor Unit

ARUN048GSS4

9.5010.50 17.00

10.50

_combined_indoorDS
SB_MultiV_Standard_Wall_Mounted_ARNU093SJA4
SB_MultiV_Standard_Wall_Mounted_ARNU123SJA4
SB_MultiV_Standard_Wall_Mounted_ARNU153SJA4
SB_MultiV_Standard_Wall_Mounted_ARNU183SKA4
SB_MultiV_Standard_Wall_Mounted_ARNU243SKA4
_combined_outdoorDS
LG_LS243HLV
Mounting
SB_MultiV_S_HP_ARUN024GSS4
SB_MultiV_S_HP_ARUN038GSS4
SB_MultiV_S_HP_ARUN048GSS4
File: Off
Approval: Off
Resubmit: Off
Architect:
GC:
Engr:
Mech:
Company:
Project Manager:
Tag #:
Job Name/Location:
Date:
PO No:
Other Field:
Other: Off
File#1: Off
Approval#1: Off
Resubmit#1: Off
Architect#1:
GC#1:
Engr#1:
Mech#1:
Company#1:
Project Manager#1:
Tag ##1:
Job Name/Location#1:
Date#1:
PO No#1:
Other Field#1:
Other#1: Off
File#2: Off
Approval#2: Off
Resubmit#2: Off
Architect#2:
GC#2:
Engr#2:
Mech#2:
Company#2:
Project Manager#2:
Tag ##2:
Job Name/Location#2:
Date#2:
PO No#2:
Other Field#2:
Other#2: Off
File#3: Off
Approval#3: Off
Resubmit#3: Off
Architect#3:
GC#3:
Engr#3:
Mech#3:
Company#3:
Project Manager#3:
Tag ##3:
Job Name/Location#3:
Date#3:
PO No#3:
Other Field#3:
Other#3: Off
File#4: Off
Approval#4: Off
Resubmit#4: Off
Architect#4:
GC#4:
Engr#4:
Mech#4:
Company#4:
Project Manager#4:
Tag ##4:
Job Name/Location#4:
Date#4:
PO No#4:
Other Field#4:
Other#4: Off
File#5: Off
Approval#5: Off
Resubmit#5: Off
Architect#5:
GC#5:
Engr#5:
Mech#5:
Company#5:
Project Manager#5:
Tag ##5:
Job Name/Location#5:
Date#5:
PO No#5:
Other#5: Off
Other Field#5:
Architect#1#1:
GC#1#1:
Engr#1#1:
Mech#1#1:
Company#1#1:
Project Manager#1#1:
File#1#1: Off
Approval#1#1: Off
Resubmit#1#1: Off
Job Name/Location#1#1:
Tag ##1#1:
Date#1#1:
PO No#1#1:
Other Field#1#1:
Other#1#1: Off
Architect#2#1:
GC#2#1:
Engr#2#1:
Mech#2#1:
Company#2#1:
Project Manager#2#1:
File#2#1: Off
Approval#2#1: Off
Resubmit#2#1: Off
Job Name/Location#2#1:
Tag ##2#1:
Date#2#1:
PO No#2#1:
Other Field#2#1:
Other#2#1: Off
Architect#3#1:
GC#3#1:
Engr#3#1:
Mech#3#1:
Company#3#1:
Project Manager#3#1:
File#3#1: Off
Approval#3#1: Off
Resubmit#3#1: Off
Job Name/Location#3#1:
Tag ##3#1:
Date#3#1:
PO No#3#1:
Other Field#3#1:
Other#3#1: Off

File details come from the government source that posted it. Updated .