S02 - ATTACHMENT 11 - Combined Drawings 1 of 6 - EHRM Upgrades Chicago.pdf

PDF 23 MB Posted

Attached to
EHRM Infrastructure Upgrades West Campus – North Chicago - Construction Federal contract opportunity
Solicitation number
36C77623B0019
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This file is an attachment to a solicitation for construction services. The Department of Veterans Affairs Technology Acquisition Center Austin is seeking offers for EHRM Infrastructure Upgrades at the West Campus facility in North Chicago, Illinois. The solicitation number is 36C77623B0019 and offers are being accepted for construction to upgrade infrastructure at the specified VA location, as depicted in the attached drawings. Interested parties should review the drawings and respond with pricing by the deadline indicated on the solicitation to be considered for award. Relevant details such as response date, award date, pricing terms, and set-asides are not provided in this attachment but may be specified in the solicitation document.

View the file

Other files for this federal contract opportunity

Other files attached to EHRM Infrastructure Upgrades West Campus – North Chicago - Construction, newest first.
File Type Posted
36C77623B0019 0010 - EHRM N Chicago West - Conference Line_Wage Rates_52.204-27.pdf PDF
Updated Wage Rates - Lake County - 06.30.23.pdf PDF
36C77623B0019 0009 - Note and Site Visit 2 Sign In Sheet.pdf PDF
Site Visit 2 Sign-In Sheet - 556-21-701 EHRM West Campus.pdf PDF
S02 - 36C77623B0019 0008 - Extension and Additional Site Visit.pdf PDF
556-21-701 EHRM West PreBid RFIs 20JUN23.pdf PDF
36C77623B0019 0007 - EHRM North Chicago (West) - Revised RFI Responses.pdf PDF
Revised Drawing Sheet GS007 - Item 133.pdf PDF
36C77623B0019 0006 - EHRM North Chicago (West) - Technical Questions.pdf PDF
36C77623B0019 0005 - EHRM North Chicago (West) - Extension 6.26.23.pdf PDF
36C77623B0019 0004 - EHRM North Chicago (West) - Extension 3.16.23.pdf PDF
36C77623B0019 0003 - EHRM North Chicago (West) - Extension.pdf PDF
36C77623B0019 0003 - Updated Wage Rates - Lake County - 05.12.23.pdf PDF
36C77623B0019 0002 - Site Visit Sign-In Sheet - North Chicago (West).pdf PDF
West Campus Site Visit sign in sheet May 15 2023.pdf PDF
01 45 29 Testing Laboratory Services.pdf PDF
36C77623B0019 0001 - EHRM North Chicago (West) - Addendum 01.pdf PDF
Addendum 001.pdf PDF
00 01 10- Table of Contents.pdf PDF
01 35 26 Safety Requirements.pdf PDF
01 35 33 Infection Control Requirements.pdf PDF
26 05 33 Raceway and Boxes for Electrical Systems.pdf PDF
27 51 16 Public Address and Mass Notification.pdf PDF
01 00 00 General Requirements.pdf PDF
01 33 23 Shop Drawings Product Data and Samples.pdf PDF
01 91 00 General Commissioning Requirements.pdf PDF
27 05 33 Raceways and Boxes for Communication Systems.pdf PDF
27 52 23 Nurse call.pdf PDF
S02 - ATTACHMENT 3 - EHRM North Chicago-100 Cost Narrative.pdf PDF
S02 - ATTACHMENT 18 - Limitations on Subcontracting - Jan 2023.pdf PDF
S02 - ATTACHMENT 19 - Contractor Safety - Environmental Form.pdf PDF
S02 - ATTACHMENT 20 - Wage Rates - Lake County - 01.20.23.pdf PDF
S02 - ATTACHMENT 4 - Environmental Comb - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 5 - 01 35 33 Infection Control Requirements FHCC 15NOV22.pdf PDF
S02 - ATTACHMENT 8 - Mechanical Calculations - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 16 - Combined Drawings 6 of 6 - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 22 - Illinois Tax Memo - 1.26.2023.pdf PDF
S02 - ATTACHMENT 7 - Mechanical Equipment - EHRM Upgrade Chicago.pdf PDF
S02 - ATTACHMENT 9 - ICRA Form - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 10 - 556-21-701 EHRM West Const SOW 20 DEC22.pdf PDF
S02 - ATTACHMENT 12 - Combined Drawings 2 of 6 - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 13 - Combined Drawings 3 of 6 - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 15 - Combined Drawings 5 of 6 - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 21 - Site Visit Instructions.pdf PDF
S02 - SOLICITATION - 36C77623B0019_1 North Chicago EHRM (West Campus).pdf PDF
S02 - ATTACHMENT 1 - 556-21-701 Bid Specifications - Final.pdf PDF
S02 - ATTACHMENT 2 - Chicago EHRM - Design Narratives.pdf PDF
S02 - ATTACHMENT 6 - Safety Requirements.pdf PDF
S02 - ATTACHMENT 14 - Combined Drawings 4 of 6 - EHRM Upgrades Chicago.pdf PDF
S02 - ATTACHMENT 17 - Brand Name Justification - Redacted.pdf PDF
Show all 50

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing #

U.S. DEPARTMENT OF VETERANS AFFAIRS

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023

MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023

ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023

CIVIL ENGINEER

OLSSON

550 E. ST. LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

2517 MADISON AVE. STE 100

KANSAS CITY, MO 64108

(913) 369-7200

STRUCTURAL ENGINEER

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST., STE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.,

OLATHE, KANSAS 66062

(913) 829-8690

/6

/2

:4

:5

A

M

COVER SHEET

BAB 1 OF 348AJS

ISSUE FOR BID & CONSTRUCTION

EHRM INFRASTRUCTURE UPGRADES,

WEST CAMPUS - NORTH CHICAGO

VA PROJECT NUMBER: 556-21-701

EHRM INFRASTRUCTURE

UPGRADES, WEST CAMPUS -

NORTH CHICAGO

12/08/2022

556-21-701

3001 GREEN BAY ROAD

NORTH CHICAGO, ILLINOIS 60064

CAPTAIN JAMES A. LOVELL FEDERAL HEALTH CARE CENTER

3001 GREEN BAY ROAD

NORTH CHICAGO, ILLINOIS 60064

ISSUE FOR BID & CONSTRUCTION

GI000

SPUR #: 2113

PROJECT LOCATION

LOCATION

PLAN

AREA

PLAN

NN

No. REVISION DESCRIPTION DATE th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023

MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023

ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023

CIVIL ENGINEER

OLSSON

550 E. ST. LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

2517 MADISON AVE. STE 100

KANSAS CITY, MO 64108

(913) 369-7200

STRUCTURAL ENGINEER

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST., STE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.,

OLATHE, KANSAS 66062

(913) 829-8690

/6

/2

:4

:5

A

M

SHEET INDEX

BAB 2 OF 348AJS

ISSUE FOR BID & CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES, WEST CAMPUS -

NORTH CHICAGO

12/08/2022

556-21-701

3001 GREEN BAY ROAD

NORTH CHICAGO, ILLINOIS 60064

GI001

SPUR #: 2113

SHEET INDEX

SEQUENCE NUMBER SHEET NAME

327 T-312 TECHNOLOGY ENLARGED PLAN - BLDG 133

328 T-313 TECHNOLOGY ENLARGED PLAN - BLDG 133

329 T-314 TECHNOLOGY ENLARGED PLAN - BLDG 133

330 T-315 TECHNOLOGY ENLARGED PLAN - BLDG 133

331 T-316 TECHNOLOGY ENLARGED PLAN - BLDG 133

332 T-317 TECHNOLOGY ENLARGED PLAN - BLDG 133

333 T-318 TECHNOLOGY ENLARGED PLAN - BLDG 133

334 T-319 TECHNOLOGY ENLARGED PLAN - BLDG 133

335 T-320 TECHNOLOGY ENLARGED PLAN - BLDG 133

336 T-321 TECHNOLOGY ENLARGED PLAN - BLDG 134

337 T-322 TECHNOLOGY ENLARGED PLAN - BLDG 134

338 T-323 TECHNOLOGY ENLARGED PLAN - BLDG 135

339 T-324 TECHNOLOGY ENLARGED PLAN - BLDG 138 & 140

340 T-325 TECHNOLOGY ENLARGED PLAN - BLDG 187

341 T-326 TECHNOLOGY ENLARGED PLAN - BLDG 188 & 195

342 T-327 TECHNOLOGY ENLARGED PLAN - BLDG 201, 202, 205 & 206

343 T-400 TECHNOLOGY DETAILS

344 T-401 TECHNOLOGY DETAILS

345 T-402 TECHNOLOGY DETAILS

346 T-403 TECHNOLOGY DETAILS

347 T-500 TECHNOLOGY RISER DIAGRAM

348 T-501 TECHNOLOGY RISER DIAGRAM

TOTAL SHEETS: 348

SHEET INDEX

SEQUENCE NUMBER SHEET NAME

[08] TELECOMMUNICATION

239 T-000 TECHNOLOGY LEGEND & ABBREVIATIONS

240 T-100 TECHNOLOGY FLOOR PLAN - BLDG 1 - LVL 1

241 T-101 TECHNOLOGY FLOOR PLAN - BLDG 1 - LVL 2

242 T-102 TECHNOLOGY FLOOR PLAN - BLDG 1 - LVL 3

243 T-103 TECHNOLOGY FLOOR PLAN - BLDG 3 - BASEMENT

244 T-104 TECHNOLOGY FLOOR PLAN - BLDG 3 - LVL 1

245 T-105 TECHNOLOGY FLOOR PLAN - BLDG 3 - LVL 2

246 T-106 TECHNOLOGY FLOOR PLAN - BLDG 4 - LVL 1

247 T-107 TECHNOLOGY FLOOR PLAN - BLDG 4 - LVL 2

248 T-108 TECHNOLOGY FLOOR PLAN - BLDG 6 - BASEMENT

249 T-109 TECHNOLOGY FLOOR PLAN - BLDG 6 - LVL1

250 T-110 TECHNOLOGY FLOOR PLAN - BLDG 7 - BASEMENT

251 T-111 TECHNOLOGY FLOOR PLAN - BLDG 7 - LVL1

252 T-112 TECHNOLOGY FLOOR PLAN - BLDG 7 - LVL2

253 T-113 TECHNOLOGY FLOOR PLAN - BLDG 9 - BASEMENT

254 T-114 TECHNOLOGY FLOOR PLAN - BLDG 9 - LVL 1

255 T-115 TECHNOLOGY FLOOR PLAN - BLDG 9 - LVL 2

256 T-116 TECHNOLOGY FLOOR PLAN - BLDG 11 - LVL 1

257 T-117 TECHNOLOGY FLOOR PLAN - BLDG 11 - LVL 2

258 T-118 TECHNOLOGY FLOOR PLAN - BLDG 32, 36, 37 - LVL 1

259 T-119 TECHNOLOGY FLOOR PLAN - BLDG 46 - BASEMENT

260 T-120 TECHNOLOGY FLOOR PLAN - BLDG 46 - LVL 1

261 T-121 TECHNOLOGY FLOOR PLAN - BLDG 46 - LVL 2

262 T-122 TECHNOLOGY FLOOR PLAN - BLDG 66 - BASEMENT

263 T-123 TECHNOLOGY FLOOR PLAN - BLDG 66 - LVL 1

264 T-124 TECHNOLOGY FLOOR PLAN - BLDG 66 - LVL 2

265 T-125 TECHNOLOGY FLOOR PLAN - BLDG 92, 138, 140-LVL 1

266 T-126 TECHNOLOGY FLOOR PLAN - BLDG 131 - BASEMENT

267 T-127 TECHNOLOGY FLOOR PLAN - BLDG 131 - LVL 1

268 T-128 TECHNOLOGY FLOOR PLAN - BLDG 131 - LVL 2

269 T-129 TECHNOLOGY FLOOR PLAN - BLDG 131 - LVL 3

270 T-130 TECHNOLOGY FLOOR PLAN - BLDG 131 - LVL 4

271 T-131 TECHNOLOGY FLOOR PLAN - BLDG 132 - BASEMENT

272 T-132 TECHNOLOGY FLOOR PLAN - BLDG 132 - LVL 1

273 T-133 TECHNOLOGY FLOOR PLAN - BLDG 133 - BASEMENT - AREA A

274 T-134 TECHNOLOGY FLOOR PLAN - BLDG 133 & 133EF - BASEMENT - AREA B

275 T-135 TECHNOLOGY FLOOR PLAN - BLDG 133 - LVL 1 - AREA A

276 T-136 TECHNOLOGY FLOOR PLAN - BLDG 133 & 133EF - LVL 1 - AREA B

277 T-137 TECHNOLOGY FLOOR PLAN - BLDG 133 - LVL 2 - AREA A

278 T-138 TECHNOLOGY FLOOR PLAN - BLDG 133 & 133EF - LVL 2 - AREA B

279 T-139 TECHNOLOGY FLOOR PLAN - BLDG 133 - LVL 3 - AREA A

280 T-140 TECHNOLOGY FLOOR PLAN - BLDG 133 & 133EF - LVL 3 - AREA B

281 T-141 TECHNOLOGY FLOOR PLAN - BLDG 133 - LVL 4

282 T-142 TECHNOLOGY FLOOR PLAN - BLDG 134 - BASEMENT

283 T-143 TECHNOLOGY FLOOR PLAN - BLDG 134 - LVL 1

284 T-144 TECHNOLOGY FLOOR PLAN - BLDG 134 - LVL 2

285 T-145 TECHNOLOGY FLOOR PLAN - BLDG 134 - LVL 3

286 T-146 TECHNOLOGY FLOOR PLAN - BLDG 135 - BASEMENT

287 T-147 TECHNOLOGY FLOOR PLAN - BLDG 135 - LVL 1

288 T-148 TECHNOLOGY FLOOR PLAN - BLDG 135 - LVL 2

289 T-149 TECHNOLOGY FLOOR PLAN - BLDG 187 & 188 - LVL 1

290 T-150 TECHNOLOGY FLOOR PLAN - BLDG 195 - LVL 1

291 T-151 TECHNOLOGY FLOOR PLAN - BLDG 201, 202, 205 & 206 - LVL 1

292 T-200 TECHNOLOGY SITE PLAN - REDUNDANT FIBER OPTIC PATHWAYS

293 T-201 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 1 & 3

294 T-202 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 4 & 46

295 T-203 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 5 & 6

296 T-204 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 7

297 T-205 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 9 & 11

298 T-206 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 32 & 36

299 T-207 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 37

300 T-208 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 48

301 T-209 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 66

302 T-210 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 92

303 T-211 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 131 & 132

304 T-212 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 134

305 T-213 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 135

306 T-214 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 138

307 T-215 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 140

308 T-216 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 187 & 188

309 T-217 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 195 & 196

310 T-218 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 201

311 T-219 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 202

312 T-220 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 205

313 T-221 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 206

314 T-222 TECHNOLOGY REDUNDANT FIBER PLAN - GUARDSHACKS

315 T-300 TECHNOLOGY ENLARGED PLAN - BLDG 1 & 3

316 T-301 TECHNOLOGY ENLARGED PLAN - BLDG 3 & 4

317 T-302 TECHNOLOGY ENLARGED PLAN - BLDG 6 & 7

318 T-303 TECHNOLOGY ENLARGED PLAN - BLDG 9, 11 & 32

319 T-304 TECHNOLOGY ENLARGED PLAN - BLDG 37

320 T-305 TECHNOLOGY ENLARGED PLAN - BLDG 36 & 46

321 T-306 TECHNOLOGY ENLARGED PLAN - BLDG 66 & 92

322 T-307 TECHNOLOGY ENLARGED PLAN - BLDG 131

323 T-308 TECHNOLOGY ENLARGED PLAN - BLDG 131, 132 & 133

324 T-309 TECHNOLOGY ENLARGED PLAN - BLDG 133

325 T-310 TECHNOLOGY ENLARGED PLAN - BLDG 133

326 T-311 TECHNOLOGY ENLARGED PLAN - BLDG 133

SHEET INDEX

SEQUENCE NUMBER SHEET NAME

[07] ELECTRICAL

152 E-000 ELECTRICAL LEGEND AND ABBREVIATIONS

153 ES101 ELECTRICAL SITE PLAN - OVERALL

154 ES401 ENLARGED ELECTRICAL SITE PLANS

155 ES402 GENERATOR BUILDING FLOOR PLANS

156 E-101 BLDG 1, 3, 4 - ELECTRICAL REFERENCE PLANS

157 E-102 BLDG 6, 7, 9 - ELECTRICAL REFERENCE PLANS

158 E-103 BLDG 11, 32, 36, 37 - ELECTRICAL REFERENCE PLANS

159 E-104 BLDG 46, 66, 92 - ELECTRICAL REFERENCE PLANS

160 E-105 BLDG 131 & 132 - ELECTRICAL REFERENCE PLANS

161 E-106 BLDG 133 - BASEMENT - ELECTRICAL REFERENCE PLANS

162 E-107 BLDG 133 - LEVEL ONE - ELECTRICAL REFERENCE PLANS

163 E-108 BLDG 133 - LEVEL TWO - ELECTRICAL REFERENCE PLANS

164 E-109 BLDG 133 - LEVEL THREE & FOUR - ELECTRICAL REFERENCE PLANS

165 E-110 BLDG 134 - BASEMENT, LEVEL ONE, TWO, & THREE - ELECTRICAL REFERENCE

PLANS

166 E-111 BLDG 135, 138, 140, 187, 188 - ELECTRICAL REFERENCE PLANS

167 E-112 BLDG 195, 201, 202, 205, 206 - ELECTRICAL REFERENCE PLANS

168 E-201 BLDG 3, 4, 6, 36, & 131 - ROOF PLANS

169 E-202 BLDG 133 - ROOF PLAN

170 E-203 BLDG 134 & 135 - ROOF PLANS

171 E-401 BLDG 1 & 3 - ELECTRICAL ENLARGED PLANS

172 E-402 BLDG 3 & 4 - ELECTRICAL ENLARGED PLANS

173 E-403 BLDG 6 & 7 - ELECTRICAL ENLARGED PLANS

174 E-404 BLDG 9, 11, & 32 - ELECTRICAL ENLARGED PLANS

175 E-405 BLDG 36, 37, & 46 - ELECTRICAL ENLARGED PLANS

176 E-406 BLDG 66, & 92 - ELECTRICAL ENLARGED PLANS

177 E-407 BLDG 131 - ELECTRICAL ENLARGED PLANS

178 E-408 BLDG 131 & 133 - ELECTRICAL ENLARGED PLANS

179 E-409 BLDG 133 - BASEMENT - ELECTRICAL ENLARGED PLANS

180 E-410 BLDG 133 - BASEMENT - ELECTRICAL ENLARGED PLANS

181 E-411 BLDG 133 - BASEMENT & LEVEL ONE - ELECTRICAL ENLARGED PLANS

182 E-412 BLDG 133 - LEVEL ONE - ELECTRICAL ENLARGED PLANS

183 E-413 BLDG 133 - LEVEL ONE - ELECTRICAL ENLARGED PLANS

184 E-414 BLDG 133 - LEVEL TWO - ELECTRICAL ENLARGED PLANS

185 E-415 BLDG 133 - LEVEL TWO - ELECTRICAL ENLARGED PLANS

186 E-416 BLDG 133 - LEVEL TWO & THREE - ELECTRICAL ENLARGED PLANS

187 E-417 BLDG 133 - LEVEL THREE - ELECTRICAL ENLARGED PLANS

188 E-418 BLDG 133 - LEVEL THREE & FOUR - ELECTRICAL ENLARGED PLANS

189 E-419 BLDG 134 - BASEMENT - ELECTRICAL ENLARGED PLANS

190 E-420 BLDG 134 - LEVEL ONE, TWO, & THREE - ELECTRICAL ENLARGED PLANS

191 E-421 BLDG 134 - LEVEL ONE & TWO - ELECTRICAL ENLARGED PLANS

192 E-422 BLDG 135 - BASEMENT, LEVEL ONE & TWO - ELECTRICAL ENLARGED PLANS

193 E-423 BLDG 138, 140, & 187 - ELECTRICAL ENLARGED PLANS

194 E-424 BLDG 188 & 195 - ELECTRICAL ENLARGED PLANS

195 E-425 BLDG 201, 202, 205, & 206 - ELECTRICAL ENLARGED PLANS

196 E-426 BLDG 1, 3, 5, 7, 9, 11, & 46 - ENLARGED ELECTRICAL ROOMS

197 E-427 BLDG 131, 133 - ENLARGED ELECTRICAL ROOMS

198 E-428 BLDG 133 - ENLARGED ELECTRICAL ROOMS

199 E-429 BLDG 133 - ENLARGED ELECTRICAL ROOMS

200 E-430 BLDG 134, 135, 187, 188, 201, 202, 205, 206 - ENLARGED ELECTRICAL ROOMS

201 E-431 BLDG 1, 3, 4, 6, 7, 9, & 11 MECHANICAL EQUIPMENT ENLARGED POWER PLANS

202 E-432 BLDG 4, 46, 66, 131, & 133 MECHANICAL EQUIPMENT ENLARGED POWER PLANS

203 E-433 BLDG 133 MECHANICAL EQUIPMENT ENLARGED POWER PLANS

204 E-434 BLDG 133, 134, & 135 MECHANICAL EQUIPMENT ENLARGED POWER PLANS

205 E-501 ELECTRICAL DETAILS

206 E-502 ELECTRICAL DETAILS

207 E-503 ELECTRICAL DETAILS

208 E-504 BLDG 1, 3, 4, 6, & 7 GROUNDING DIAGRAMS

209 E-505 BLDG 9, 11, 46, & 66 GROUNDING DIAGRAMS

210 E-506 BLDG 133 & 133CA GROUNDING DIAGRAM

211 E-507 BLDG 133EF GROUNDING DIAGRAM

212 E-508 BLDG 131, 134, & 135 GROUNDING DIAGRAMS

213 E-509 BLDG 201, 202, 205, & 206 GROUNDING DIAGRAMS

214 E-601 BLDG 1 & 3 ELECTRICAL ONE-LINE DIAGRAMS

215 E-602 BLDG 4, 5 & 6 ELECTRICAL ONE-LINE DIAGRAM

216 E-603 BLDG 7 & 9 ELECTRICAL ONE-LINE DIAGRAMS

217 E-604 BLDG 11, 32, 36, 37, 46, 92, & 138 ELECTRICAL ONE-LINE DIAGRAMS

218 E-605 BLDG 66 ELECTRICAL ONE-LINE DIAGRAM

219 E-606 BLDG 131 - ELECTRICAL ONE-LINE DIAGRAM

220 E-607 BLDG 133 - ELECTRICAL ONE-LINE DIAGRAM

221 E-608 BLDG 133CA - ELECTRICAL ONE-LINE DIAGRAM

222 E-609 BLDG 133EF - ELECTRICAL ONE-LINE DIAGRAM

223 E-610 BLDG 134 - ELECTRICAL ONE-LINE DIAGRAM

224 E-611 BLDG 135 - ELECTRICAL ONE-LINE DIAGRAM

225 E-612 BLDG 187, 188 & 195 - ELECTRICAL ONE-LINE DIAGRAM

226 E-613 BLDG 201 & 202 - ELECTRICAL ONE-LINE DIAGRAM

227 E-614 BLDG 205 & 206 - ELECTRICAL ONE-LINE DIAGRAM

228 E-615 ELECTRICAL SCHEDULES

229 E-616 BLDG 1, 3 & 4 - PANEL SCHEDULES

230 E-617 BLDG 6, 7, 9 & 11 - PANEL SCHEDULES

231 E-618 BLDG 32, 46, 66 & 92 - PANEL SCHEDULES

232 E-619 BLDG 131, 132 & 133 - PANEL SCHEDULES

233 E-620 BLDG 133 - PANEL SCHEDULES

234 E-621 BLDG 133 - PANEL SCHEDULES

235 E-622 BLDG 133 - PANEL SCHEDULES

236 E-623 BLDG 133 & 134 - PANEL SCHEDULES

237 E-624 BLDG 138, 140, 187, 195, 201, 202, 205, & 206 - PANEL SCHEDULES

238 E-625 BLDG 135, BBLN3 & CP-2-K18 - PANEL SCHEDULES

SHEET INDEX

SEQUENCE NUMBER SHEET NAME

[05] FIRE PROTECTION

79 FA101 OVERALL FIRE ALARM PLANS

80 FA102 OVERALL FIRE ALARM PLANS

81 FA103 OVERALL FIRE ALARM PLANS

82 FA104 OVERALL FIRE ALARM PLANS

83 FA105 OVERALL FIRE ALARM PLANS

84 FA106 OVERALL FIRE ALARM PLANS

85 FA107 OVERALL FIRE ALARM PLANS

86 FA401 ENLARGED FIRE ALARM PLANS

87 FA402 ENLARGED FIRE ALARM PLANS

88 FA403 ENLARGED FIRE ALARM PLANS

89 FA404 ENLARGED FIRE ALARM PLANS

90 FA405 ENLARGED FIRE ALARM PLANS

91 FA406 ENLARGED FIRE ALARM PLANS

92 FA407 ENLARGED FIRE ALARM PLANS

93 FA408 ENLARGED FIRE ALARM PLANS

94 FA409 ENLARGED FIRE ALARM PLANS

95 FA410 ENLARGED FIRE ALARM PLANS

96 FX101 OVERALL FIRE SUPPRESSION PLANS

97 FX102 OVERALL FIRE SUPPRESSION PLANS

98 FX103 OVERALL FIRE SUPPRESSION PLANS

99 FX104 OVERALL FIRE SUPPRESSION PLANS

100 FX105 OVERALL FIRE SUPPRESSION PLANS

101 FX106 OVERALL FIRE SUPPRESSION PLANS

102 FX107 OVERALL FIRE SUPPRESSION PLANS

103 FX401 ENLARGED FIRE SUPPRESSION PLANS

104 FX402 ENLARGED FIRE SUPPRESSION PLANS

105 FX403 ENLARGED FIRE SUPPRESSION PLANS

106 FX404 ENLARGED FIRE SUPPRESSION PLANS

107 FX405 ENLARGED FIRE SUPPRESSION PLANS

108 FX406 ENLARGED FIRE SUPPRESSION PLANS

109 FX407 ENLARGED FIRE SUPPRESSION PLANS

110 FX408 ENLARGED FIRE SUPPRESSION PLANS

111 FX409 ENLARGED FIRE SUPPRESSION PLANS

112 FX410 ENLARGED FIRE SUPPRESSION PLANS

[06] MECHANICAL

113 M-000 LEGEND AND ABBREVIATIONS

114 M-101 BLDG 1, 3, 4 - REFERENCE PLANS

115 M-102 BLDG 6, 7, 9 - REFERENCE PLANS

116 M-103 BLDG 11, 32, 36, 37 - REFERENCE PLANS

117 M-104 BLDG 46, 66, 92 - REFERENCE PLANS

118 M-105 BLDG 131, 132 - REFERENCE PLANS

119 M-106 BLDG 133 - BASEMENT - REFERENCE PLANS

120 M-107 BLDG 133 - LEVEL ONE - REFERENCE PLANS

121 M-108 BLDG 133 - LEVEL TWO - REFERENCE PLANS

122 M-109 BLDG 133 - LEVEL THREE & FOUR - REFERENCE PLANS

123 M-110 BLDG 134 - BASEMENT, LEVEL ONE, TWO & THREE - REFERENCE PLANS

124 M-111 BLDG 135, 138, 140, 187, 188 - REFERENCE PLANS

125 M-112 BLDG 195, 201, 202, 205, 206 - REFERENCE PLANS

126 M-201 BLDG 3, 4, 6, & 131 - ROOF PLANS

127 M-202 BLDG 133 - ROOF PLAN

128 M-203 BLDG 134 & 135 - ROOF PLANS

129 M-401 BLDG 1, 3, & 4 - ENLARGED PLANS

130 M-402 BLDG 6 & 7 - ENLARGED PLANS

131 M-403 BLDG 9, 11, & 32 - ENLARGED PLANS

132 M-404 BLDG 36, 37, & 46 - ENLARGED PLANS

133 M-405 BLDG 66 & 92 - ENLARGED PLANS

134 M-406 BLDG 131 - ENLARGED PLANS

135 M-407 BLDG 132 & 133 - ENLARGED PLANS

136 M-408 BLDG 133 - BASEMENT - ENLARGED PLANS

137 M-409 BLDG 133 - LEVEL ONE - ENLARGED PLANS

138 M-410 BLDG 133 - LEVEL ONE - ENLARGED PLANS CONT.

139 M-411 BLDG 133 - LEVEL TWO - ENLARGED PLANS

140 M-412 BLDG 133 - LEVEL TWO - ENLARGED PLANS CONT.

141 M-413 BLDG 133 - LEVEL THREE - ENLARGED PLANS

142 M-414 BLDG 133 - LEVEL THREE & FOUR - ENLARGED PLANS

143 M-415 BLDG 134 - BASEMENT - ENLARGED PLAN

144 M-416 BLDG 134 - LEVEL ONE, TWO, & THREE - ENLARGED PLANS

145 M-417 BLDG 135 - ENLARGED PLANS

146 M-418 BLDG 138, 140, & 187 - ENLARGED PLANS

147 M-419 BLDG 188, 195, 201, 202, 205, & 206 - ENLARGED PLANS

148 M-501 MECHANICAL DETAILS

149 M-502 MECHANICAL DETAILS CONT.

150 M-601 MECHANICAL SCHEDULES

151 M-701 MECHANICAL CONTROLS

SHEET INDEX

SEQUENCE NUMBER SHEET NAME

[01] GENERAL

1 GI000 COVER SHEET

2 GI001 SHEET INDEX

3 GI002 GENERAL INFORMATION

[02] CIVIL

4 GS001 GENERAL LAYOUT

5 GS002 EXISTING CONDITIONS WITH EXISTING DUCT BANK ROUTES (VA)

6 GS003 EXISTING CONDITIONS WITH NEW DUCT BANK ROUTES (GIS)

7 GS004 OVERALL SITE AND DEMOLITION PLAN

8 GS005 ENLARGED SITE AND DEMOLITION PLAN 1

9 GS006 ENLARGED SITE AND DEMOLITION PLAN 2

10 GS007 ENLARGED SITE AND DEMOLITION PLAN 3

11 GS008 ENLARGED SITE AND DEMOLITION PLAN 4

12 GS009 ENLARGED SITE AND DEMOLITION PLAN 5

13 GS010 ENLARGED SITE AND DEMOLITION PLAN 6

14 GS011 ENLARGED SITE AND DEMOLITION PLAN 7

15 GS012 ENLARGED SITE AND DEMOLITION PLAN 8

16 GS013 UTILITY PLAN NW QUADRANT

17 GS014 UTILITY PLAN NE QUADRANT

18 GS015 UTILITY PLAN SW QUADRANT

19 GS016 UTILITY PLAN SE QUADRANT

20 GS017 EROSION CONTROL PLAN NW QUADRANT

21 GS018 EROSION CONTROL PLAN NE QUADRANT

22 GS019 EROSION CONTROL PLAN SW QUADRANT

23 GS020 EROSION CONTROL PLAN SE QUADRANT

24 GS021 EROSION CONTROL DETAILS

25 GS022 DETAILS

[03] STRUCTURAL

26 S-001 STRUCTURAL GENERAL NOTES

27 S-201 BLDG 3, 4, 5, 6, & 131 - ROOF PLANS

28 S-202 BLDG 133 - ROOF PLAN

29 S-203 BLDG 134 & 135 - ROOF PLANS

[04] ARCHITECTURAL

30 A-101 BLDG 1, 3, 4 - REFERENCE PLANS

31 A-102 BLDG 6, 7, 9 - REFERENCE PLANS

32 A-103 BLDG 11, 32, 36, 37 - REFERENCE PLANS

33 A-104 BLDG 46, 66, 92 - REFERENCE PLANS

34 A-105 BLDG 131 & 132 - REFERENCE PLANS

35 A-106 BLDG 133 - BASEMENT - REFERENCE PLANS

36 A-107 BLDG 133 - LEVEL ONE - REFERENCE PLANS

37 A-108 BLDG 133 - LEVEL TWO - REFERENCE PLANS

38 A-109 BLDG 133 - LEVEL THREE, & FOUR - REFERENCE PLANS

39 A-110 BLDG 134 - BASEMENT, LEVEL ONE, TWO, & THREE - REFERENCE PLANS

40 A-111 BLDG 135, 138, 140, 187, 188 - REFERENCE PLANS

41 A-112 BLDG 195, 201, 202, 205, 206 - REFERENCE PLANS

42 AE101 BLDG 1 & 3 - ENLARGED PLANS

43 AE102 BLDG 3 & 4 - ENLARGED PLANS

44 AE103 BLDG 6 - LEVEL ONE - ENLARGED PLANS

45 AE104 BLDG 7 - LEVEL ONE & TWO - ENLARGED PLANS

46 AE105 BLDG 9 - ENLARGED PLANS

47 AE106 BLDG 11 & 32 - ENLARGED VIEWS

48 AE107 BLDG 36 & 37 - ENLARGED PLANS

49 AE108 BLDG 46 & 66 - ENLARGED PLANS

50 AE109 BLDG 66, 92, & 131 - ENLARGED PLANS

51 AE110 BLDG 131 - LEVEL ONE, TWO, THREE, & FOUR - ENLARGED PLANS

52 AE111 BLDG 132 & 133 - ENLARGED PLANS

53 AE112 BLDG 133 - BASEMENT - ENLARGED PLANS

54 AE113 BLDG 133 - BASEMENT - ENLARGED PLANS

55 AE114 BLDG 133 - BASEMENT - ENLARGED PLANS

56 AE115 BLDG 133 - LEVEL ONE - ENLARGED PLANS

57 AE116 BLDG 133 - LEVEL ONE - ENLARGED PLANS

58 AE117 BLDG 133 - LEVEL ONE - ENLARGED PLANS

59 AE118 BLDG 133 - LEVEL ONE - ENLARGED PLANS

60 AE119 BLDG 133 - LEVEL TWO - ENLARGED PLANS

61 AE120 BLDG 133 - LEVEL TWO - ENLARGED PLANS

62 AE121 BLDG 133 - LEVEL TWO - ENLARGED PLANS

63 AE122 BLDG 133 - LEVEL THREE - ENLARGED PLANS

64 AE123 BLDG 133 - LEVEL THREE - ENLARGED PLANS

65 AE124 BLDG 133 - LEVEL THREE - SERVER ROOM - ENLARGED PLANS

66 AE125 BLDG 133 - LEVEL THREE - SERVER ROOM - ENLARGED PLANS

67 AE126 BLDG 133 - LEVEL THREE & FOUR - ENLARGED PLANS

68 AE127 BLDG 134 - BASEMENT - ENLARGED PLANS

69 AE128 BLDG 134 - BASEMENT - ENLARGED PLANS

70 AE129 BLDG 134 - LEVEL ONE & TWO - ENLARGED PLANS

71 AE130 BLDG 134 & 135 - ENLARGED PLANS

72 AE131 BLDG 135 - LEVEL ONE & TWO - ENLARGED PLANS

73 AE132 BLDG 135, 138, & 140 - ENLARGED PLANS

74 AE133 BLDG 187 - LEVEL ONE - ENLARGED PLANS

75 AE134 BLDG 188 & 195 - ENLARGED PLANS

76 AE135 BLDG 201, 202, 205, & 206 - ENLARGED PLANS

77 AE601 DOOR SCHEDULE

78 AF711 PARTITION, FINISH SCHEDULES & DETAILS

EHRM INFRASTRUCTURE UPGRADES,

WEST CAMPUS - NORTH CHICAGO

VA PROJECT NUMBER: 556-221-701

VOLUME 1 VOLUME 2

ABBREVIATIONS CODES STANDARDS AND EXECUTIVE ORDERS

4' -0

M

A X

4' -0

M

A X

2' -1

0" M

A X

2' -3

M

IN

1'-6" MIN

1. GENERAL CONTRACTOR TO PROVIDE METAL SUPPORT

BLOCKING FOR ALL WALL MOUNTED ACCESSORIES,

FIXTURES, AND EQUIPMENT.

2. PROVIDE ADA SUPPORT BRACKETS PLACED AT ALL OPEN

COUNTERTOPS @ 36"-48" MAX ON CENTER.

3. SPECIFIED MAXIMUMS ARE MEASURED FROM AFTER

FINISHED FLOOR TO THE OPERABLE PART OF THE FIXTURE.

4. FIXTURES SHOWN ARE REPRESENTATIONAL ONLY. NOT ALL

FIXTURES MAY BE USED. REFER TO SPECIFICATIONS FOR

FIXTURE TYPES USED IN THIS PROJECT.

5. FIXTURES MAY OVERLAP WAINSCOT. WHERE APPLICABLE,

BACKING TO BE PROVIDED AS SHIM FOR FLUSH

APPLICATION. SHIM TO MATCH SCHEDULED WALL FINISH.

6" MAX

9" M

IN

SHOWER

VA TOILET ROOM

TURNING RADIUS

DRINKING

FOUNTAIN

PAPER TOWEL

DISPENSER

SANITARY

NAPKIN

DISPENSER

4' -0

"M A

X

WASTE

RECEPTACLE

LAVATORY

WITH MIRROR

ON CENTER

WALL

4' -0

M

A X

SOAP

DISPENSER

2' -1

0" M

A X

T O

B .O

. R E

F

LE

C T

IV

E

S U

R F

A C

E

3' -4

"M A

X

17 MIN

2' -3

M

IN

3' -0

M

A X

1'-6" MIN

WALL

2' -9

3' -1

/3 2"

M

IN

2'-0" MIN

8" MIN

WALL

LAVATORY

WITH APRON

1' -5

M

A X

1'-6" MIN

URINAL

WALL

1'-5" - 1'-7" (AMBULATORY)

1'-4" - 1'-6" (WHEELCHAIR)

CLEAR FLOOR

5'-6"

CLEAR FLOOR

6'-0"

3'-0" MIN

2' -9

3' -0

1'-0" MIN

3'-6" MIN 1'-0"MAX

4'-6" MIN

1' -5

'-7

1' -6

M

IN

A N

S I I

C C

A

7.

1)

1' -3

M

IN

A D

A /A

B A

2' -9

'-0

WALL

WALL

4' -0

M

A X

WALL HOOK

7' -0

CLOCK

WALL

FINISHED FLOOR

FIRE EXTINGUISHER

CABINET

WEIGHT > 40LBS

FIRE EXTINGUISHER

CABINET

WEIGHT < 40LBS

3' -1

1/

6" M

A X

4' -0

M

A X

TOILET SEAT

COVER

DISPENSER

BABY

CHANGING

STATION

CLEAR FLOOR SPACE

@ WATER CLOSET

5'-6"

2'-6"

4' -0

2'-6"

4' -0

HANDRAILS AND

BUMPERGUARDS

FIXTURE MOUNTING HEIGHTS AND CLEARANCES

18" MIN

M

IN

FRONT APPROACH,

PULL SIDE

36" MIN

M

IN

HINGE APPROACH,

PULL SIDE

HINGE APPROACH,

PULL SIDE

*12" MIN48

M

IN

FRONT APPROACH,

PUSH SIDE

M

IN

HINGE APPROACH,

PUSH SIDE

22" MIN 24" MIN*4

8"

M

IN

LATCH APPROACH,

PULL SIDE

24" MIN*4

2"

M

IN

LATCH APPROACH,

PUSH SIDE

*IF BOTH CLOSER

AND LATCH ARE

PROVIDED

*54" MIN IF CLOSER

IS PROVIDED

*48" IF CLOSER IS

PROVIDED

FRONT APPROACH,

PUSH SIDE

M

IN

42" MIN

DOOR AND FIXTURE CLEARANCES

MATERIALS LEGEND

PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN

VOLUNTARY STANDARD BODIES.

GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS

SPECIFY OTHER CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:

• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL

INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).

• 2021 INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)

• 2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC) (IF APPLICABLE)

• 2021 NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)

• 2021 NATIONAL FIRE CODES (NFPA)

• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.

• 2020 VA SEISMIC DESIGN REQUIREMENTS, H-18-8

• 2021 VA PHYSICAL SECURITY & RESILIENCY DESIGN MANUAL

• 2021 INTERNATIONAL MECHANICAL CODE

• 2020 NATIONAL ELECTRICAL CODE (NEC), NFPA 70

• 2021 INTERNATIONAL PLUMBING CODE (IPC)

• 2016 SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.

• 2015 ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS INCLUDING VA SUPPLEMENT, VA BARRIER FREE DESIGN STANDARD (PG-18-13)

• 2017 ANSI ICC A117.1 ACCESIBLE AND USABLE BUILDINGS AND FACILITIES

• 2019 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318-19)

• 2017 STEEL CONSTRUCTION MANUAL (15TH EDITION), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)

• ENERGY POLICY ACT OF 2005 (EPACT)

• 2007 DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND

NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.

• 2006 FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)

• 2018 EXECUTIVE ORDER 13834: EFFICIENT FEDERAL OPERATIONS

• 2021 THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 010000 OF THE VA MASTER CONSTRUCTION

SPECIFICATION.

• 2019 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1

• 2019 SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15

LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.

NOTES:

1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT

NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN.

DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES

EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).

2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.

ASHRAE 90.1 - 2019 EDITION

BUILDING LOCATION: CHICAGO, ILLINOIS

CLIMATE ZONE (TABLE ANNEX 1-1): ZONE 5A

INTERIOR DESIGN CONDITIONS:

THE INTERIOR DESIGN TEMPERATURES FOR HEATING AND COOLING AS DEPICTED IN THE PROJECT DESIGN CONDITIONS SCHEDULE IN THE MECHANICAL CONTROL DRAWINGS SHALL BE THE MAXIMUM

AND MINIMUM VALUES FOR THE ASSOCIATED TEMPERATURE CONTROL ZONES.

BUILDING ENVELOPE REQUIREMENTS (5.5 )

BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 4 (A,B,C)

ROOFS REQUIRED DESIGNED

INSULATION: R-30 c.i. EXISTING METAL BUILDINGS: R-19 + R-11 Ls or R-25 + R-8 Ls EXISTING

ATTIC AND OTHER: R-49 EXISTING

WALLS, ABOVE GRADE

MASS: R-9.5 c.i. EXISTING METAL BUILDING: R-0 + R-15.8 c.i. EXISTING STEEL-FRAMED: R-13 + R-7.5 c.i. EXISTING WOOD-FRAMED AND OTHER: R-13 + R-3.8 c.i. or R-20 EXISTING

WALL, BELOW GRADE

BELOW-GRADE WALL: R-7.5 c.i. EXISTING

FLOORS

MASS: R-14.6 c.i. EXISTING

STEEL-FRAMED: R-30 EXISTING

WOOD-FRAMED AND OTHER: R-30 EXISTING

SLAB-ON-GRADE FLOORS

UNHEATED SLABS: R-15 for 24 in. EXISTING HEATED SLABS: R-20 for 24 in. EXISTING

OPAQUE DOORS

SWINGING: U-0.370 EXISTING

NONSWINGING: U-0.310 EXISTING

FENESTRATION (TABLE 5.5-4):

VERTICAL FENESTRATION, U-FACTOR

FIXED: U-0.36 EXISTING

OPERABLE: U-0.45 EXISTING

ENTRANCE DOOR: U-0.63 EXISTING

DEFINITIONS

c.i = CONTINUOUS INSULATION Ls = LINEAR SYSTEM

NR = NO (INSULATION) REQUIREMENT

NO EXTERIOR IMPROVEMENTS INCLUDED IN THE SCOPE OF THIS PROJECT.

ENERGY REQUIREMENTS

N

1. DRAWINGS ARE PART OF A COMPLETE DOCUMENTS SET. CONTRACTOR SHALL

CONFIRM ALL ITEMS REQUIRED BASED UPON THE OVERALL DESIGN INTENT OF THE

ENTIRE DOCUMENT SET.

2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, PRIOR TO BEGINNING ANY

WORK, TO CONFIRM THE ACCURACY OF THE DRAWINGS AND REPORT ANY

DISCREPANCIES TO THE ARCHITECT. DO NOT SCALE THE DRAWINGS. FIELD VERIFY

ALL DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.

3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS PROJECT SHALL BE KEPT

CLEAN AND FREE OF OBSTRUCTIONS AT ALL TIMES.

4. ERECT BARRICADES AND WARNING SIGNS TO DIVERT AND WARN PASSERS-BY OF THE

CONSTRUCTION WORK. PROVIDE DUST PROOFING ENCLOSURES TO SEPARATE WORK

AREAS FROM THE EXISTING FACILITIES.

5. ALL TRASH AND DEBRIS TO BE REMOVED ON A DAILY BASIS.

6. PROVIDE PROTECTION FOR ALL EXISTING SURFACES AND CONDITIONS TO REMAIN IN

PLACE DURING THE SCOPE OF WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND

REPAIR ANY DAMAGE TO ADJACENT FINISHES TO MATCH EXISTING.

7. ANY DAMAGE CAUSED TO THE BUILDING OR OWNER EQUIPMENT SHALL BE REPAIRED

OR REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL COST TO THE

OWNER.

8. COVER ALL RETURN AIR GRILLES WITHIN THE AREA OF CONSTRUCTION TO PREVENT

PARTICULATE MATERIAL FROM EXHAUSTING INTO SURROUNDING SPACES.

9. APPROPRIATE LIGHT FIXTURES SHALL BE TEMPORARILY SUSPENDED TO PROVIDE

ADEQUATE LIGHTING LEVELS FOR CONSTRUCTION.

10. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO COORDINATE WITH OTHER

DISCIPLINES TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS. DRAWINGS, AS A

WHOLE, REPRESENT A COMPLETE SET AND DEPICT REQUIREMENTS FOR COMPLETE

AND OPERATIONAL SYSTEMS. INDIVIDUAL DRAWINGS MAY NOT DEPICT COMPLETE AND

ACCURATE INFORMATION TO COORDINATE COMPLETE AND OPERATIONAL SYSTEMS,

BUT DO SO AS AN ENTIRE DOCUMENT TO BE REFERENCED WITH OTHER INDIVIDUAL

DRAWINGS. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO REFERENCE

OTHER SHEETS AND SPECIFICATIONS AS AN ENTIRE SET OF CONSTRUCTION

DOCUMENTS THAT REFLECT WORK REQUIRED TO ACHIEVE A COMPLETE AND

OPERATIONAL GOAL. LACK OF COORDINATION AND REVIEW OF DRAWINGS AND

SPECIFICATIONS AS AN ENTIRE DOCUMENT TO INSTALL COMPLETE AND OPERATIONAL

SYSTEMS, BEING OBVIOUS AND TYPICAL INDUSTRY STANDARD, IDENTIFIED IN THE

DRAWINGS AND SPECIFICATIONS, SHALL NOT BE IN ANY WAY AN ADDITIONAL COST TO

THE GOVERNMENT.

11. CONTRACTOR SHALL SUBMIT A REQUEST, IN WRITING, TO INTERRUPT ANY SUCH

SERVICES TO COR (CONTRACTING OFFICER’S REPRESENTATIVE) 48 HOURS IN

ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE,

EXACT TIME OF, AND APPROXIMATE DURATION OF SUCH INTERRUPTION. MAJOR

INTERRUPTIONS OF ANY SYSTEM MUST BE REQUESTED, IN WRITING, AT LEAST 60

CALENDAR DAYS PRIOR TO THE DESIRED TIME AND SHALL BE PERFORMED AS

DIRECTED BY THE COR. MAJOR INTERRUPTIONS SHALL BE COORDINATED WITH OTHER

MAJOR INTERRUPTIONS AND MAY NOT BE SCHEDULED FOR ONE DISCIPLINE MORE

THAN TWICE THROUGHOUT THE OVERALL CONSTRUCTION SCHEDULE UNLESS

REQUESTED IN WRITING AND APPROVED BY THE COR. CONTRACTOR WILL BE ADVISED,

IN WRITING, OF APPROVAL OF REQUEST, OR OF WHICH OTHER DATE AND/OR TIME

SUCH INTERRUPTION WILL CAUSE THE LEAST INCONVENIENCE TO OPERATIONS OF

THE MEDICAL CENTER. INTERRUPTION TIME APPROVED BY THE MEDICAL CENTER MAY

OCCUR AT TIMES OTHER THAN CONTRACTOR'S NORMAL WORKING HOURS. SCHEDULE

INTERRUPTION MAY BE ON WEEKENDS OR LATE HOURS AND MAY NOT BE AN

ADDITIONAL COST TO THE GOVERNMENT. COORDINATE ALL INTERRUPTIONS THAT MAY

AFFECT THE NORMAL OPERATION OF THE FACILITY WITH THE COR WHEN SUBMITTING

THE CONSTRUCTION SCHEDULE OR UPDATES TO THE CONSTRUCTION SCHEDULE.

12. NO ASBESTOS CONTAINING MATERIALS ARE TO BE USED ON THIS PROJECT. SPUR

DESIGN, THE A/E OF RECORD, CAN CERTIFY THAT NO ASBESTOS CONTAINING

BUILDING MATERIALS (ACBM) OR LEAD BASED PAINT (LBP) PRODUCTS WERE

DESIGNED/SPECIFIED AS BUILDING MATERIAL IN ANY OF THE CONSTRUCTION

DOCUMENTS.

13. PROVIDE A CLEAN AGENT FIRE EXTINGUISHER LOCATED IN A CABINET AND INSTALLED

AT EACH TELECOMMUNICATION ROOM (TR) AT A LOCATION NO GREATER THAN 75 FEET

AWAY. PROVIDE ADDITIONAL SIGNAGE TO INDICATE THAT FIRE EXTINGUISHER IS TO BE

USED FOR TR ONLY.

GENERAL NOTES

AREA NAME

150 SF

A101

A101

SIM

A

00.0

A101

1 1

A101

LEVEL NAME

00'-00"

00'-00" 4B

3A

FIBERGLASS BATT

INSULATION

RIGID INSULATION

CONCRETE / PRECAST

CONCRETE

EARTH / SOIL

SAND, EIFS FINISH, OR

PLASTER FINISH

GYPSUM BOARD FINISH

BRICK

CONCRETE MASONRY

UNIT

STONE / CAST STONE

GYPSUM BOARD SECTION

EXTERIOR SHEATHING

BOARD SECTION

PLYWOOD SECTION

ROOM NAME

000A150 SF/

PROGRAMMED

AREA

/1 A101

X0000

6"

3' -0

M

A X

ROOM TAG

AREA TAG

SPECIALTY EQUIPMENT TAG

DOOR TAG

KEYED NOTE TAG

WALL TAG

WINDOW TAG

A101

SIM

A101

SIM

A

ACB ACOUSTIC CEILING BAFFLE

ACP ACOUSTIC CEILING PANEL

ACST ACOUSTIC

ADA AMERICANS WITH DISABILITIES ACT

ACT ACOUSTICAL CEILING TILE

ADDL ADDITIONAL

ADDN ADDITION

ADJ ADJACENT, ADJOINING, OR

ADJUSTABLE

ADMIN ADMINISTRATION

AE ARCHITECT/ENGINEER

AF ACCESS FLOORING

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AHJ AUTHORITY HAVING JURISDICTION

AIA AMERICAN INSTITUTE OF

ARCHITECTS

ALT ALTERNATE

ALT NO ALTERNATE NUMBER

ALUM ALUMINIUM (TRIM)

AMT AMOUNT

APPROX APPROXIMATE

ARCH ARCHITECT

ASC ABOVE SUSPENDED CEILING

AT ACOUSTIC CEILING TILE

AVG AVERAGE

B

BD BOARD

BLDG BUILDING

BLKG BLOCKING

BLT IN BUILT-IN

BOS BOTTOM OF STEEL

BOT BOTTOM

BRKT BRACKET

BTWN BETWEEN

C

CAB CABINET

CAV CAVITY

CBB CONCRETE BACKER BOARD

CD CONSTRUCTION DOCUMENTS

CFM CUBIC FEET PER MINUTE

CFS CUBIC FEET PER SECOND

CG CORNER GUARD

CH BD CHALK BOARD

CIP CAST-IN-PLACE

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLG HT CEILING HEIGHT

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CO CONTRACTING OFFICER

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONT CONTINUOUS

COORD COORDINATE

COR CONTRACTING OFFICER'S

REPRESENTATIVE

CP CONTRACTOR PROVIDED

CP/CI CONTRACTOR PROVIDED /

CONTRACTOR INSTALLED

CPT CAROET/CARPET TILE

CS CONCRETE SEALED

CSWK CASEWORK

CT CERAMIC TILE

CTB CERAMIC TILE BASE

CTR CENTER

CU FT CUBIC FEET

D

DBL DOUBLE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DIA DIAMETER

DIR DIRECTION

DIST DISTANCE

DOC DOCUMENT

DR DOOR

DS DOWNSPOUT

DWG DRAWING

DWP DIMENSIONAL WALL PANEL

E

EA EACH

EJ EXPANSION JOINT

EL ELEVATION

ELEV ELEVATOR

ENTR ENTRANCE

EPY EPXOY FLOORING

EQ EQUAL

ETR EXISTING TO REMAIN

EX EXISTING

EXP EXPOSED

EXT EXTERIOR

F

FAB FABRIC

FED FEDERAL

FF FINISH FACE

FF EL FINISH FLOOR ELEVATION

FIN FINISH

FIN BS FINISH BOTH SIDES

FIN FLR FINISH FLOOR

FIN GR FINISH GRADE

FIXT FIXTURE

FLDG FOLDING

FLEX FLEXIBLE

FLG FLOORING

FLMT FLUSH MOUNT

FLR FLOOR

FOC FACE OF CONCRETE

FOM FACE OF MASONRY

FP FIRE PROTECTION

FR FIRE RESISTANT

FRP FIRE RATED PLYWOOD

FT FEET

FTG FOOTING

FV FIELD VERIFY

FWC FABRIC WALL COVERING

G

GDR GUARDRAIL

GL GLASS/GLAZING

GRAN GRANITE

GR FL GROUND FLOOR

GT GROUT

GSM GALVANIZED SHEET METAL

GYP BD GYPSUM BOARD

H

HDW HARDWARE

HEPA HIGH EFFICIENCY

PARTICULATE AIR (FILTER)

HM HOLLOW METAL

HORIZ HORIZONTAL

HR HANDRAIL

HT HEIGHT

I

IBC INTERNATIONAL BUILDING CODE

INSUL INSULATION

INT INTERIOR

ILO IN LIEU OF

J

J-BOX JUNCTION BOX

L

LAV LAVATORY

LBS POUND

LDG LANDING

LF LINEAR FEET (FOOT)

LIN LINEAR

LN LINOLEUM

LOC LOCATION

LT LIGHT

LVR LOUVER

LVT LUXURY VINYL TILE

M

MAT CARPET MAT / WALK-OFF MAT

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MEMB MEMBRANE

MFR MANUFACTURER

MID MIDDLE

MIL STD MILITARY STANDARD

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MOD MODIFY

MTG MOUNTING

MTL METAL

MVBL MOVABLE

N

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

O

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER

OPNG OPENING

OPP OPPOSITE

OPR OPERABLE

ORD OVERFLOW ROOF DRAIN

ORIG ORIGINAL

OTS OPEN TO STRUCTURE

P

P PAINT

PA PUBLIC ADDRESS

PBD PARTICLE BOARD

PCF POUNDS PER CUBIC FOOT

PCT PERCENT

PERF PERFORATED

PERIM PERIMETER

PERP PERPENDICULAR

PL PROPERTY LINE

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PNL PANEL

PR PAIR

PRB PROFILE BASE

PRKG PARKING

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PORCELAIN TILE

PWR POWER

Q

QA QUALITY ASSURANCE

QC QUALITY CONTROL

QTY QUANTITY

REFERENCE SYMBOLS IDENTIFICATION TAGS

NOTE: NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR THIS PROJECT.

GRID HEAD AND

LINE

LEVEL INDICATOR

MATCH LINE AND

VIEW REFERENCE

NORTH ARROW W/

PROJECT NORTH

SPOT ELEVATION

DETAIL

SECTION

**48" MIN IF BOTH CLOSER

AND LATCH PROVIDED

WALL

SECTION

BUILDING

SECTION

DETAIL

ELEVATION

INTERIOR

ELEVATION

BUILDING

ELEVATION

1 1

6'- 0"

5'- 6"

BARIATRIC TOILET ROOM

TURNING RADIUS

CLEAR FLOOR SPACE

@ ADA LAVATORY

CLEAR FLOOR SPACE @ ADA

DRINKING FOUNTAIN

4 7/256"

6 1/32"

3"

7/

6"

1' -6

/3

2"

6" MAX

7" - 9" 11" MIN

17" - 25"

M

IN

6' -0

(ANSI ICC A117.1)

39"- 41"

(A N

S I I

C C

A

7.

1)

M

IN

(A N

S I I

C C

A

7.

1)

1"

3' -5

/2

M

A X

4' -1

1/

6" M

A X

R

RAF RESILIENT ATHETIC FLOORING

RB RUBBER BASE/RESILIENT BASE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REC RECESSED

REF REFERENCE

REM REMOVABLE

REP REPAIR

REPL REPLACE

REQ REQUIRE

REQD REQUIRED

RES RESINOUS FLOORING

RES-W RESINOUS / EPOXY WALL / CEILING

RF RUBBER FLOORING

RFG ROOFING

RM ROOM

RO ROUGH OPENING

RP RESIN PANEL

RSF RESILIENT SHEET FLOORING

RV ROOF VENT

RWC RIGID VINYL WALLCOVERING

S

SC SEALED CONCRETE

SDT STATIC DISSIPATIVE FLOORING/TILE

SCHED SCHEDULE

SECT SECTION

SF SQUARE FOOT (FEET)

SGL SINGLE

SIM SIMILAR

SJ SCORED JOINT

SLNT SEALANT

SM SHEET METAL

SPEC SPECIFICATION

SQ SQUARE

SQ IN SQUARE INCH

SQ YD SQUARE YARD

SS SOLID SURFACE

ST STONE

STD STANDARD

STOR STORAGE

SV SHEET VINYL (ROLLED OR TILE)

T

TEL TELEPHONE

TEMP TEMPORARY

TER TERRAZO

TOF TOP OF FOOTING/ FOUNDATION

TOM TOP OF MASONRY

TOS TOP OF SLAB/ STEEL

TE TELECOMMUNICATIONS ENCLOSURE

TR TELECOMMUNICATIONS ROOM

U

UNO UNLESS NOTED OTHERWISE

UTIL UTILITY

V

VAR VARIES

VC VA PROVIDED / CONTRACTOR

INSTALLED

VCT VINYL COMPOSITION TILE

VFAT VINYL FACED ACOUSTICLAL TILE

VP VENEERED PLASTER

VT VINYL TILE

VV VA PROVIDED / VA INSTALLED

VWC VINYL WALLCOVERING

VWF VINYL WALL FABRIC

W

W/ WITH

W/O WITHOUT

W/C WATER CLOSET

WC WHEELCHAIR

WD WOOD

WFAB WALL FABRIC

WPM WATERPROOF MEMBRANE

WSF WELDED SHEET FLOOR

X

X BRACE CROSS BRACE

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023

MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023

ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023

CIVIL ENGINEER

OLSSON

550 E. ST. LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

2517 MADISON AVE. STE 100

KANSAS CITY, MO 64108

(913) 369-7200

STRUCTURAL ENGINEER

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST., STE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.,

OLATHE, KANSAS 66062

(913) 829-8690

/6

/2

:4

:5

A

M

GENERAL INFORMATION

BAB 3 OF 348AJS

ISSUE FOR BID & CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES, WEST CAMPUS -

NORTH CHICAGO

12/08/2022

556-21-701

3001 GREEN BAY ROAD

NORTH CHICAGO, ILLINOIS 60064

GI002

SPUR #: 2113

ISSUED FOR BID & CONSTRUCTION

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

FULLY SPRINKLERED

STAMP:

Drawing Number

Building Number

/1

/2

1:

P

M

AMA 348CRW

EHRM INFRASTRUCTURE

UPGRADES, WEST CAMPUS -

NORTH CHICAGO

12/08/2022

556-221-701

CAPTAIN JAMES A. LOVELL FHCC

3001 GREEN BAY ROAD

NORTH CHICAGO, ILLINOIS 60064

SPUR #: 2113

No. REVISION DESCRIPTION DATE

CIVIL ENGINEER

OLSSON

550 E. ST. LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

2519 MADISON AVE. STE 100

KANSAS CITY, MO 64108

(913) 369-7200

STRUCTURAL ENGINEER

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST., STE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.,

OLATHE, KANSAS 66062

(913) 829-8690

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

C O

N

TR

O

LL

E D

U N

C

LA

S S

IF

IE

D

IN

FO

R

M A

TI

O

N (C

U I)

ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023

MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023

ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023

www.olsson.comTEL 417.890.8802

550 St. Louis St.

Springfield, MO 65806 Olsson # 021-06005

Olsson, Inc. Engineering IL State Cert. of Authority 184.003968-0010

GIS PROVIDED BACKGROUND

SHOWN ON THIS SHEET

GS001

GENERAL LAYOUT PLAN

DEMOLITION NOTES: PAVEMENT MARKING NOTES:

GENERAL NOTES:

CALL 811 SEVENTY-TWO HOURS PRIOR TO

DIGGING, GRADING OR EXCAVATING FOR THE

MARKING OF UNDERGROUND MEMBER UTILITIES.

Know what's below.

before you dig.CallR

LEGEND

BUILDING SCOPE TABLE:

SURVEY NOTES:

exp. 11/30/2023

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

FULLY SPRINKLERED

STAMP:

Drawing Number

Building Number

/1

/2

1:

P

M

AMA 348CRW

EHRM INFRASTRUCTURE

UPGRADES, WEST CAMPUS -

NORTH CHICAGO

12/08/2022

556-221-701

CAPTAIN JAMES A. LOVELL FHCC

3001 GREEN BAY ROAD

NORTH CHICAGO, ILLINOIS 60064

SPUR #: 2113

No. REVISION DESCRIPTION DATE

CIVIL ENGINEER

OLSSON

550 E. ST. LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

2519 MADISON AVE. STE 100

KANSAS CITY, MO 64108

(913) 369-7200

STRUCTURAL ENGINEER

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST., STE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.,

OLATHE, KANSAS 66062

(913) 829-8690

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

C O

N

TR

O

LL

E D

U N

C

LA

S S

IF

IE

D

IN

FO

R

M A

TI

O

N (C

U I)

ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023

MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023

ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023

www.olsson.comTEL 417.890.8802

550 St. Louis St.

Springfield, MO 65806 Olsson # 021-06005

Olsson, Inc. Engineering IL State Cert. of Authority 184.003968-0010

GS002

EXISTING CONDITIONS WITH EXISTING

DUCT BANK ROUTES (VA)

GENERAL NOTES:

CALL 811 SEVENTY-TWO HOURS PRIOR TO

DIGGING, GRADING OR EXCAVATING FOR THE

MARKING OF UNDERGROUND MEMBER UTILITIES.

Know what's below.

before you dig.CallR

(VA PROVIDED SURVEY)

VA PROVIDED BACKGROUND

SHOWN ON THIS SHEET

LEGEND

GENERAL NOTES:

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

FULLY SPRINKLERED

STAMP:

Drawing Number

Building Number

/1

/2

1:

P

M

AMA 348CRW

EHRM INFRASTRUCTURE

UPGRADES, WEST CAMPUS -

NORTH CHICAGO

12/08/2022

556-221-701

CAPTAIN JAMES A. LOVELL FHCC

3001 GREEN BAY ROAD

NORTH CHICAGO, ILLINOIS 60064

SPUR #: 2113

No. REVISION DESCRIPTION DATE

CIVIL ENGINEER

OLSSON

550 E. ST. LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

2519 MADISON AVE. STE 100

KANSAS CITY, MO 64108

(913) 369-7200

STRUCTURAL ENGINEER

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST., STE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.,

OLATHE, KANSAS 66062

(913) 829-8690

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

C O

N

TR

O

LL

E D

U N

C

LA

S S

IF

IE

D

IN

FO

R

M A

TI

O

N (C

U I)

ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023

MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023

ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023

www.olsson.comTEL 417.890.8802

550 St. Louis St.

Springfield, MO 65806 Olsson # 021-06005

Olsson, Inc. Engineering IL State Cert. of Authority 184.003968-0010

GIS PROVIDED BACKGROUND

SHOWN ON THIS SHEET

GS003

EXISTING CONDITIONS WITH NEW

DUCT BANK ROUTES (GIS)

CALL 811 SEVENTY-TWO HOURS PRIOR TO

DIGGING, GRADING OR EXCAVATING FOR THE

MARKING OF UNDERGROUND MEMBER UTILITIES.

Know what's below.

before you dig.CallR

(GIS SURVEY PLUS GIS AERIAL)

LEGEND

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

FULLY SPRINKLERED

STAMP:

Drawing Number

Building Number

/1

/2

1:

P

M

AMA 348CRW

EHRM INFRASTRUCTURE

UPGRADES, WEST CAMPUS -

NORTH CHICAGO

12/08/2022

556-221-701

CAPTAIN JAMES A. LOVELL FHCC

3001 GREEN BAY ROAD

NORTH CHICAGO, ILLINOIS 60064

SPUR #: 2113

No. REVISION DESCRIPTION DATE

CIVIL ENGINEER

OLSSON

550 E. ST. LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

2519 MADISON AVE. STE 100

KANSAS CITY, MO 64108

(913) 369-7200

STRUCTURAL ENGINEER

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST., STE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.,

OLATHE, KANSAS 66062

(913) 829-8690

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

C O

N

TR

O

LL

E D

U N

C

LA

S S

IF

IE

D

IN

FO

R

M A

TI

O

N (C

U I)

ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023

MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023

ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023

www.olsson.comTEL 417.890.8802

550 St. Louis St.

Springfield, MO 65806 Olsson # 021-06005

Olsson, Inc. Engineering IL State Cert. of Authority 184.003968-0010

GIS PROVIDED BACKGROUND

SHOWN ON THIS SHEET

GS004

OVERALL SITE AND DEMOLITION PLAN

CALL 811 SEVENTY-TWO HOURS PRIOR TO

DIGGING, GRADING OR EXCAVATING FOR THE

MARKING OF UNDERGROUND MEMBER UTILITIES.

Know what's below.

before you dig.CallR

SURVEY NOTES:

SEE ENLARGED SITE

AND DEMOLITION PLAN 8

(SHEET GS012)

SEE ENLARGED SITE

AND DEMOLITION PLAN 7

(SHEET GS011)

SEE ENLARGED SITE

AND DEMOLITION PLAN 6

(SHEET GS010)

SEE ENLARGED SITE

AND DEMOLITION PLAN 5

(SHEET GS009

SEE ENLARGED SITE

AND DEMOLITION PLAN 1

(SHEET GS005)

SEE ENLARGED SITE

AND DEMOLITION PLAN 2

(SHEET GS006)

SEE ENLARGED SITE

AND DEMOLITION PLAN 3

(SHEET GS007)

SEE ENLARGED SITE

AND DEMOLITION PLAN 4

(SHEET GS008)

ENLARGED SITE AND DEMOLITION PLAN 1

GS005

ISSUED FOR BID & CONSTRUCTION

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

FULLY SPRINKLERED

STAMP:

Drawing Number

Building Number

/1

/2

1:

P

M

AMA 348CRW

EHRM INFRASTRUCTURE

UPGRADES, WEST CAMPUS -

NORTH CHICAGO

12/08/2022

556-221-701

CAPTAIN JAMES A. LOVELL FHCC

3001 GREEN BAY ROAD

NORTH CHICAGO, ILLINOIS 60064

SPUR #: 2113

No. REVISION DESCRIPTION DATE

CIVIL ENGINEER

OLSSON

550 E. ST. LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

2519 MADISON AVE. STE 100

KANSAS CITY, MO 64108

(913) 369-7200

STRUCTURAL ENGINEER

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST., STE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.,

OLATHE, KANSAS 66062

(913) 829-8690

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

C O

N

TR

O

LL

E D

U N

C

LA

S S

IF

IE

D

IN

FO

R

M A

TI

O

N (C

U I)

ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023

MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023

ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023

www.olsson.comTEL 417.890.8802

550 St. Louis St.

Springfield, MO 65806 Olsson # 021-06005

Olsson, Inc. Engineering IL State Cert. of Authority 184.003968-0010

GIS PROVIDED BACKGROUND

SHOWN ON THIS SHEET

CALL 811 SEVENTY-TWO HOURS PRIOR TO

DIGGING, GRADING OR EXCAVATING FOR THE

MARKING OF UNDERGROUND MEMBER UTILITIES.

Know what's below.

before you dig.CallR

FOR LEGEND

SEE SHEET GS008

SURVEY NOTES:

CAUTION REGARDING EXISTING UTILITIES

LEGEND

GENERAL NOTES:

KEYNOTES:

ENLARGED SITE AND DEMOLITION PLAN 2

GS006

ISSUED FOR BID & CONSTRUCTION

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

FULLY SPRINKLERED

STAMP:

Drawing Number

Building Number

/1

/2

1:

P

M

AMA 348CRW

EHRM INFRASTRUCTURE

UPGRADES, WEST CAMPUS -

NORTH CHICAGO

12/08/2022

556-221-701

CAPTAIN JAMES A. LOVELL FHCC

3001 GREEN BAY ROAD

NORTH CHICAGO, ILLINOIS 60064

SPUR #: 2113

No. REVISION DESCRIPTION DATE

CIVIL ENGINEER

OLSSON

550…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .