S02 - ATTACHMENT 11 - Combined Drawings 1 of 6 - EHRM Upgrades Chicago.pdf
PDF 23 MB Posted
- Attached to
- EHRM Infrastructure Upgrades West Campus – North Chicago - Construction Federal contract opportunity
- Solicitation number
- 36C77623B0019
About this file
This file is an attachment to a solicitation for construction services. The Department of Veterans Affairs Technology Acquisition Center Austin is seeking offers for EHRM Infrastructure Upgrades at the West Campus facility in North Chicago, Illinois. The solicitation number is 36C77623B0019 and offers are being accepted for construction to upgrade infrastructure at the specified VA location, as depicted in the attached drawings. Interested parties should review the drawings and respond with pricing by the deadline indicated on the solicitation to be considered for award. Relevant details such as response date, award date, pricing terms, and set-asides are not provided in this attachment but may be specified in the solicitation document.
View the file
Other files for this federal contract opportunity
Show all 50
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
U.S. DEPARTMENT OF VETERANS AFFAIRS
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023
MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023
ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023
CIVIL ENGINEER
OLSSON
550 E. ST. LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2517 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
STRUCTURAL ENGINEER
STAND (SEI)
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT (RSH)
1139 OLIVE ST., STE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATION
ASPEN COMMUNICATIONS
7 KIJI-DAVA CIRCLE, STE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FIRE PROTECTION ENGR
POOLE FIRE PROTECTION
19910 WEST 161ST ST.,
OLATHE, KANSAS 66062
(913) 829-8690
/6
/2
:4
:5
A
M
COVER SHEET
BAB 1 OF 348AJS
ISSUE FOR BID & CONSTRUCTION
EHRM INFRASTRUCTURE UPGRADES,
WEST CAMPUS - NORTH CHICAGO
VA PROJECT NUMBER: 556-21-701
EHRM INFRASTRUCTURE
UPGRADES, WEST CAMPUS -
NORTH CHICAGO
12/08/2022
556-21-701
3001 GREEN BAY ROAD
NORTH CHICAGO, ILLINOIS 60064
CAPTAIN JAMES A. LOVELL FEDERAL HEALTH CARE CENTER
3001 GREEN BAY ROAD
NORTH CHICAGO, ILLINOIS 60064
ISSUE FOR BID & CONSTRUCTION
GI000
SPUR #: 2113
PROJECT LOCATION
LOCATION
PLAN
AREA
PLAN
NN
No. REVISION DESCRIPTION DATE th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023
MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023
ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023
CIVIL ENGINEER
OLSSON
550 E. ST. LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2517 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
STRUCTURAL ENGINEER
STAND (SEI)
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT (RSH)
1139 OLIVE ST., STE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATION
ASPEN COMMUNICATIONS
7 KIJI-DAVA CIRCLE, STE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FIRE PROTECTION ENGR
POOLE FIRE PROTECTION
19910 WEST 161ST ST.,
OLATHE, KANSAS 66062
(913) 829-8690
/6
/2
:4
:5
A
M
SHEET INDEX
BAB 2 OF 348AJS
ISSUE FOR BID & CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES, WEST CAMPUS -
NORTH CHICAGO
12/08/2022
556-21-701
3001 GREEN BAY ROAD
NORTH CHICAGO, ILLINOIS 60064
GI001
SPUR #: 2113
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
327 T-312 TECHNOLOGY ENLARGED PLAN - BLDG 133
328 T-313 TECHNOLOGY ENLARGED PLAN - BLDG 133
329 T-314 TECHNOLOGY ENLARGED PLAN - BLDG 133
330 T-315 TECHNOLOGY ENLARGED PLAN - BLDG 133
331 T-316 TECHNOLOGY ENLARGED PLAN - BLDG 133
332 T-317 TECHNOLOGY ENLARGED PLAN - BLDG 133
333 T-318 TECHNOLOGY ENLARGED PLAN - BLDG 133
334 T-319 TECHNOLOGY ENLARGED PLAN - BLDG 133
335 T-320 TECHNOLOGY ENLARGED PLAN - BLDG 133
336 T-321 TECHNOLOGY ENLARGED PLAN - BLDG 134
337 T-322 TECHNOLOGY ENLARGED PLAN - BLDG 134
338 T-323 TECHNOLOGY ENLARGED PLAN - BLDG 135
339 T-324 TECHNOLOGY ENLARGED PLAN - BLDG 138 & 140
340 T-325 TECHNOLOGY ENLARGED PLAN - BLDG 187
341 T-326 TECHNOLOGY ENLARGED PLAN - BLDG 188 & 195
342 T-327 TECHNOLOGY ENLARGED PLAN - BLDG 201, 202, 205 & 206
343 T-400 TECHNOLOGY DETAILS
344 T-401 TECHNOLOGY DETAILS
345 T-402 TECHNOLOGY DETAILS
346 T-403 TECHNOLOGY DETAILS
347 T-500 TECHNOLOGY RISER DIAGRAM
348 T-501 TECHNOLOGY RISER DIAGRAM
TOTAL SHEETS: 348
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[08] TELECOMMUNICATION
239 T-000 TECHNOLOGY LEGEND & ABBREVIATIONS
240 T-100 TECHNOLOGY FLOOR PLAN - BLDG 1 - LVL 1
241 T-101 TECHNOLOGY FLOOR PLAN - BLDG 1 - LVL 2
242 T-102 TECHNOLOGY FLOOR PLAN - BLDG 1 - LVL 3
243 T-103 TECHNOLOGY FLOOR PLAN - BLDG 3 - BASEMENT
244 T-104 TECHNOLOGY FLOOR PLAN - BLDG 3 - LVL 1
245 T-105 TECHNOLOGY FLOOR PLAN - BLDG 3 - LVL 2
246 T-106 TECHNOLOGY FLOOR PLAN - BLDG 4 - LVL 1
247 T-107 TECHNOLOGY FLOOR PLAN - BLDG 4 - LVL 2
248 T-108 TECHNOLOGY FLOOR PLAN - BLDG 6 - BASEMENT
249 T-109 TECHNOLOGY FLOOR PLAN - BLDG 6 - LVL1
250 T-110 TECHNOLOGY FLOOR PLAN - BLDG 7 - BASEMENT
251 T-111 TECHNOLOGY FLOOR PLAN - BLDG 7 - LVL1
252 T-112 TECHNOLOGY FLOOR PLAN - BLDG 7 - LVL2
253 T-113 TECHNOLOGY FLOOR PLAN - BLDG 9 - BASEMENT
254 T-114 TECHNOLOGY FLOOR PLAN - BLDG 9 - LVL 1
255 T-115 TECHNOLOGY FLOOR PLAN - BLDG 9 - LVL 2
256 T-116 TECHNOLOGY FLOOR PLAN - BLDG 11 - LVL 1
257 T-117 TECHNOLOGY FLOOR PLAN - BLDG 11 - LVL 2
258 T-118 TECHNOLOGY FLOOR PLAN - BLDG 32, 36, 37 - LVL 1
259 T-119 TECHNOLOGY FLOOR PLAN - BLDG 46 - BASEMENT
260 T-120 TECHNOLOGY FLOOR PLAN - BLDG 46 - LVL 1
261 T-121 TECHNOLOGY FLOOR PLAN - BLDG 46 - LVL 2
262 T-122 TECHNOLOGY FLOOR PLAN - BLDG 66 - BASEMENT
263 T-123 TECHNOLOGY FLOOR PLAN - BLDG 66 - LVL 1
264 T-124 TECHNOLOGY FLOOR PLAN - BLDG 66 - LVL 2
265 T-125 TECHNOLOGY FLOOR PLAN - BLDG 92, 138, 140-LVL 1
266 T-126 TECHNOLOGY FLOOR PLAN - BLDG 131 - BASEMENT
267 T-127 TECHNOLOGY FLOOR PLAN - BLDG 131 - LVL 1
268 T-128 TECHNOLOGY FLOOR PLAN - BLDG 131 - LVL 2
269 T-129 TECHNOLOGY FLOOR PLAN - BLDG 131 - LVL 3
270 T-130 TECHNOLOGY FLOOR PLAN - BLDG 131 - LVL 4
271 T-131 TECHNOLOGY FLOOR PLAN - BLDG 132 - BASEMENT
272 T-132 TECHNOLOGY FLOOR PLAN - BLDG 132 - LVL 1
273 T-133 TECHNOLOGY FLOOR PLAN - BLDG 133 - BASEMENT - AREA A
274 T-134 TECHNOLOGY FLOOR PLAN - BLDG 133 & 133EF - BASEMENT - AREA B
275 T-135 TECHNOLOGY FLOOR PLAN - BLDG 133 - LVL 1 - AREA A
276 T-136 TECHNOLOGY FLOOR PLAN - BLDG 133 & 133EF - LVL 1 - AREA B
277 T-137 TECHNOLOGY FLOOR PLAN - BLDG 133 - LVL 2 - AREA A
278 T-138 TECHNOLOGY FLOOR PLAN - BLDG 133 & 133EF - LVL 2 - AREA B
279 T-139 TECHNOLOGY FLOOR PLAN - BLDG 133 - LVL 3 - AREA A
280 T-140 TECHNOLOGY FLOOR PLAN - BLDG 133 & 133EF - LVL 3 - AREA B
281 T-141 TECHNOLOGY FLOOR PLAN - BLDG 133 - LVL 4
282 T-142 TECHNOLOGY FLOOR PLAN - BLDG 134 - BASEMENT
283 T-143 TECHNOLOGY FLOOR PLAN - BLDG 134 - LVL 1
284 T-144 TECHNOLOGY FLOOR PLAN - BLDG 134 - LVL 2
285 T-145 TECHNOLOGY FLOOR PLAN - BLDG 134 - LVL 3
286 T-146 TECHNOLOGY FLOOR PLAN - BLDG 135 - BASEMENT
287 T-147 TECHNOLOGY FLOOR PLAN - BLDG 135 - LVL 1
288 T-148 TECHNOLOGY FLOOR PLAN - BLDG 135 - LVL 2
289 T-149 TECHNOLOGY FLOOR PLAN - BLDG 187 & 188 - LVL 1
290 T-150 TECHNOLOGY FLOOR PLAN - BLDG 195 - LVL 1
291 T-151 TECHNOLOGY FLOOR PLAN - BLDG 201, 202, 205 & 206 - LVL 1
292 T-200 TECHNOLOGY SITE PLAN - REDUNDANT FIBER OPTIC PATHWAYS
293 T-201 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 1 & 3
294 T-202 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 4 & 46
295 T-203 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 5 & 6
296 T-204 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 7
297 T-205 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 9 & 11
298 T-206 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 32 & 36
299 T-207 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 37
300 T-208 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 48
301 T-209 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 66
302 T-210 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 92
303 T-211 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 131 & 132
304 T-212 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 134
305 T-213 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 135
306 T-214 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 138
307 T-215 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 140
308 T-216 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 187 & 188
309 T-217 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 195 & 196
310 T-218 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 201
311 T-219 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 202
312 T-220 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 205
313 T-221 TECHNOLOGY REDUNDANT FIBER PLAN - BLDG 206
314 T-222 TECHNOLOGY REDUNDANT FIBER PLAN - GUARDSHACKS
315 T-300 TECHNOLOGY ENLARGED PLAN - BLDG 1 & 3
316 T-301 TECHNOLOGY ENLARGED PLAN - BLDG 3 & 4
317 T-302 TECHNOLOGY ENLARGED PLAN - BLDG 6 & 7
318 T-303 TECHNOLOGY ENLARGED PLAN - BLDG 9, 11 & 32
319 T-304 TECHNOLOGY ENLARGED PLAN - BLDG 37
320 T-305 TECHNOLOGY ENLARGED PLAN - BLDG 36 & 46
321 T-306 TECHNOLOGY ENLARGED PLAN - BLDG 66 & 92
322 T-307 TECHNOLOGY ENLARGED PLAN - BLDG 131
323 T-308 TECHNOLOGY ENLARGED PLAN - BLDG 131, 132 & 133
324 T-309 TECHNOLOGY ENLARGED PLAN - BLDG 133
325 T-310 TECHNOLOGY ENLARGED PLAN - BLDG 133
326 T-311 TECHNOLOGY ENLARGED PLAN - BLDG 133
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[07] ELECTRICAL
152 E-000 ELECTRICAL LEGEND AND ABBREVIATIONS
153 ES101 ELECTRICAL SITE PLAN - OVERALL
154 ES401 ENLARGED ELECTRICAL SITE PLANS
155 ES402 GENERATOR BUILDING FLOOR PLANS
156 E-101 BLDG 1, 3, 4 - ELECTRICAL REFERENCE PLANS
157 E-102 BLDG 6, 7, 9 - ELECTRICAL REFERENCE PLANS
158 E-103 BLDG 11, 32, 36, 37 - ELECTRICAL REFERENCE PLANS
159 E-104 BLDG 46, 66, 92 - ELECTRICAL REFERENCE PLANS
160 E-105 BLDG 131 & 132 - ELECTRICAL REFERENCE PLANS
161 E-106 BLDG 133 - BASEMENT - ELECTRICAL REFERENCE PLANS
162 E-107 BLDG 133 - LEVEL ONE - ELECTRICAL REFERENCE PLANS
163 E-108 BLDG 133 - LEVEL TWO - ELECTRICAL REFERENCE PLANS
164 E-109 BLDG 133 - LEVEL THREE & FOUR - ELECTRICAL REFERENCE PLANS
165 E-110 BLDG 134 - BASEMENT, LEVEL ONE, TWO, & THREE - ELECTRICAL REFERENCE
PLANS
166 E-111 BLDG 135, 138, 140, 187, 188 - ELECTRICAL REFERENCE PLANS
167 E-112 BLDG 195, 201, 202, 205, 206 - ELECTRICAL REFERENCE PLANS
168 E-201 BLDG 3, 4, 6, 36, & 131 - ROOF PLANS
169 E-202 BLDG 133 - ROOF PLAN
170 E-203 BLDG 134 & 135 - ROOF PLANS
171 E-401 BLDG 1 & 3 - ELECTRICAL ENLARGED PLANS
172 E-402 BLDG 3 & 4 - ELECTRICAL ENLARGED PLANS
173 E-403 BLDG 6 & 7 - ELECTRICAL ENLARGED PLANS
174 E-404 BLDG 9, 11, & 32 - ELECTRICAL ENLARGED PLANS
175 E-405 BLDG 36, 37, & 46 - ELECTRICAL ENLARGED PLANS
176 E-406 BLDG 66, & 92 - ELECTRICAL ENLARGED PLANS
177 E-407 BLDG 131 - ELECTRICAL ENLARGED PLANS
178 E-408 BLDG 131 & 133 - ELECTRICAL ENLARGED PLANS
179 E-409 BLDG 133 - BASEMENT - ELECTRICAL ENLARGED PLANS
180 E-410 BLDG 133 - BASEMENT - ELECTRICAL ENLARGED PLANS
181 E-411 BLDG 133 - BASEMENT & LEVEL ONE - ELECTRICAL ENLARGED PLANS
182 E-412 BLDG 133 - LEVEL ONE - ELECTRICAL ENLARGED PLANS
183 E-413 BLDG 133 - LEVEL ONE - ELECTRICAL ENLARGED PLANS
184 E-414 BLDG 133 - LEVEL TWO - ELECTRICAL ENLARGED PLANS
185 E-415 BLDG 133 - LEVEL TWO - ELECTRICAL ENLARGED PLANS
186 E-416 BLDG 133 - LEVEL TWO & THREE - ELECTRICAL ENLARGED PLANS
187 E-417 BLDG 133 - LEVEL THREE - ELECTRICAL ENLARGED PLANS
188 E-418 BLDG 133 - LEVEL THREE & FOUR - ELECTRICAL ENLARGED PLANS
189 E-419 BLDG 134 - BASEMENT - ELECTRICAL ENLARGED PLANS
190 E-420 BLDG 134 - LEVEL ONE, TWO, & THREE - ELECTRICAL ENLARGED PLANS
191 E-421 BLDG 134 - LEVEL ONE & TWO - ELECTRICAL ENLARGED PLANS
192 E-422 BLDG 135 - BASEMENT, LEVEL ONE & TWO - ELECTRICAL ENLARGED PLANS
193 E-423 BLDG 138, 140, & 187 - ELECTRICAL ENLARGED PLANS
194 E-424 BLDG 188 & 195 - ELECTRICAL ENLARGED PLANS
195 E-425 BLDG 201, 202, 205, & 206 - ELECTRICAL ENLARGED PLANS
196 E-426 BLDG 1, 3, 5, 7, 9, 11, & 46 - ENLARGED ELECTRICAL ROOMS
197 E-427 BLDG 131, 133 - ENLARGED ELECTRICAL ROOMS
198 E-428 BLDG 133 - ENLARGED ELECTRICAL ROOMS
199 E-429 BLDG 133 - ENLARGED ELECTRICAL ROOMS
200 E-430 BLDG 134, 135, 187, 188, 201, 202, 205, 206 - ENLARGED ELECTRICAL ROOMS
201 E-431 BLDG 1, 3, 4, 6, 7, 9, & 11 MECHANICAL EQUIPMENT ENLARGED POWER PLANS
202 E-432 BLDG 4, 46, 66, 131, & 133 MECHANICAL EQUIPMENT ENLARGED POWER PLANS
203 E-433 BLDG 133 MECHANICAL EQUIPMENT ENLARGED POWER PLANS
204 E-434 BLDG 133, 134, & 135 MECHANICAL EQUIPMENT ENLARGED POWER PLANS
205 E-501 ELECTRICAL DETAILS
206 E-502 ELECTRICAL DETAILS
207 E-503 ELECTRICAL DETAILS
208 E-504 BLDG 1, 3, 4, 6, & 7 GROUNDING DIAGRAMS
209 E-505 BLDG 9, 11, 46, & 66 GROUNDING DIAGRAMS
210 E-506 BLDG 133 & 133CA GROUNDING DIAGRAM
211 E-507 BLDG 133EF GROUNDING DIAGRAM
212 E-508 BLDG 131, 134, & 135 GROUNDING DIAGRAMS
213 E-509 BLDG 201, 202, 205, & 206 GROUNDING DIAGRAMS
214 E-601 BLDG 1 & 3 ELECTRICAL ONE-LINE DIAGRAMS
215 E-602 BLDG 4, 5 & 6 ELECTRICAL ONE-LINE DIAGRAM
216 E-603 BLDG 7 & 9 ELECTRICAL ONE-LINE DIAGRAMS
217 E-604 BLDG 11, 32, 36, 37, 46, 92, & 138 ELECTRICAL ONE-LINE DIAGRAMS
218 E-605 BLDG 66 ELECTRICAL ONE-LINE DIAGRAM
219 E-606 BLDG 131 - ELECTRICAL ONE-LINE DIAGRAM
220 E-607 BLDG 133 - ELECTRICAL ONE-LINE DIAGRAM
221 E-608 BLDG 133CA - ELECTRICAL ONE-LINE DIAGRAM
222 E-609 BLDG 133EF - ELECTRICAL ONE-LINE DIAGRAM
223 E-610 BLDG 134 - ELECTRICAL ONE-LINE DIAGRAM
224 E-611 BLDG 135 - ELECTRICAL ONE-LINE DIAGRAM
225 E-612 BLDG 187, 188 & 195 - ELECTRICAL ONE-LINE DIAGRAM
226 E-613 BLDG 201 & 202 - ELECTRICAL ONE-LINE DIAGRAM
227 E-614 BLDG 205 & 206 - ELECTRICAL ONE-LINE DIAGRAM
228 E-615 ELECTRICAL SCHEDULES
229 E-616 BLDG 1, 3 & 4 - PANEL SCHEDULES
230 E-617 BLDG 6, 7, 9 & 11 - PANEL SCHEDULES
231 E-618 BLDG 32, 46, 66 & 92 - PANEL SCHEDULES
232 E-619 BLDG 131, 132 & 133 - PANEL SCHEDULES
233 E-620 BLDG 133 - PANEL SCHEDULES
234 E-621 BLDG 133 - PANEL SCHEDULES
235 E-622 BLDG 133 - PANEL SCHEDULES
236 E-623 BLDG 133 & 134 - PANEL SCHEDULES
237 E-624 BLDG 138, 140, 187, 195, 201, 202, 205, & 206 - PANEL SCHEDULES
238 E-625 BLDG 135, BBLN3 & CP-2-K18 - PANEL SCHEDULES
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[05] FIRE PROTECTION
79 FA101 OVERALL FIRE ALARM PLANS
80 FA102 OVERALL FIRE ALARM PLANS
81 FA103 OVERALL FIRE ALARM PLANS
82 FA104 OVERALL FIRE ALARM PLANS
83 FA105 OVERALL FIRE ALARM PLANS
84 FA106 OVERALL FIRE ALARM PLANS
85 FA107 OVERALL FIRE ALARM PLANS
86 FA401 ENLARGED FIRE ALARM PLANS
87 FA402 ENLARGED FIRE ALARM PLANS
88 FA403 ENLARGED FIRE ALARM PLANS
89 FA404 ENLARGED FIRE ALARM PLANS
90 FA405 ENLARGED FIRE ALARM PLANS
91 FA406 ENLARGED FIRE ALARM PLANS
92 FA407 ENLARGED FIRE ALARM PLANS
93 FA408 ENLARGED FIRE ALARM PLANS
94 FA409 ENLARGED FIRE ALARM PLANS
95 FA410 ENLARGED FIRE ALARM PLANS
96 FX101 OVERALL FIRE SUPPRESSION PLANS
97 FX102 OVERALL FIRE SUPPRESSION PLANS
98 FX103 OVERALL FIRE SUPPRESSION PLANS
99 FX104 OVERALL FIRE SUPPRESSION PLANS
100 FX105 OVERALL FIRE SUPPRESSION PLANS
101 FX106 OVERALL FIRE SUPPRESSION PLANS
102 FX107 OVERALL FIRE SUPPRESSION PLANS
103 FX401 ENLARGED FIRE SUPPRESSION PLANS
104 FX402 ENLARGED FIRE SUPPRESSION PLANS
105 FX403 ENLARGED FIRE SUPPRESSION PLANS
106 FX404 ENLARGED FIRE SUPPRESSION PLANS
107 FX405 ENLARGED FIRE SUPPRESSION PLANS
108 FX406 ENLARGED FIRE SUPPRESSION PLANS
109 FX407 ENLARGED FIRE SUPPRESSION PLANS
110 FX408 ENLARGED FIRE SUPPRESSION PLANS
111 FX409 ENLARGED FIRE SUPPRESSION PLANS
112 FX410 ENLARGED FIRE SUPPRESSION PLANS
[06] MECHANICAL
113 M-000 LEGEND AND ABBREVIATIONS
114 M-101 BLDG 1, 3, 4 - REFERENCE PLANS
115 M-102 BLDG 6, 7, 9 - REFERENCE PLANS
116 M-103 BLDG 11, 32, 36, 37 - REFERENCE PLANS
117 M-104 BLDG 46, 66, 92 - REFERENCE PLANS
118 M-105 BLDG 131, 132 - REFERENCE PLANS
119 M-106 BLDG 133 - BASEMENT - REFERENCE PLANS
120 M-107 BLDG 133 - LEVEL ONE - REFERENCE PLANS
121 M-108 BLDG 133 - LEVEL TWO - REFERENCE PLANS
122 M-109 BLDG 133 - LEVEL THREE & FOUR - REFERENCE PLANS
123 M-110 BLDG 134 - BASEMENT, LEVEL ONE, TWO & THREE - REFERENCE PLANS
124 M-111 BLDG 135, 138, 140, 187, 188 - REFERENCE PLANS
125 M-112 BLDG 195, 201, 202, 205, 206 - REFERENCE PLANS
126 M-201 BLDG 3, 4, 6, & 131 - ROOF PLANS
127 M-202 BLDG 133 - ROOF PLAN
128 M-203 BLDG 134 & 135 - ROOF PLANS
129 M-401 BLDG 1, 3, & 4 - ENLARGED PLANS
130 M-402 BLDG 6 & 7 - ENLARGED PLANS
131 M-403 BLDG 9, 11, & 32 - ENLARGED PLANS
132 M-404 BLDG 36, 37, & 46 - ENLARGED PLANS
133 M-405 BLDG 66 & 92 - ENLARGED PLANS
134 M-406 BLDG 131 - ENLARGED PLANS
135 M-407 BLDG 132 & 133 - ENLARGED PLANS
136 M-408 BLDG 133 - BASEMENT - ENLARGED PLANS
137 M-409 BLDG 133 - LEVEL ONE - ENLARGED PLANS
138 M-410 BLDG 133 - LEVEL ONE - ENLARGED PLANS CONT.
139 M-411 BLDG 133 - LEVEL TWO - ENLARGED PLANS
140 M-412 BLDG 133 - LEVEL TWO - ENLARGED PLANS CONT.
141 M-413 BLDG 133 - LEVEL THREE - ENLARGED PLANS
142 M-414 BLDG 133 - LEVEL THREE & FOUR - ENLARGED PLANS
143 M-415 BLDG 134 - BASEMENT - ENLARGED PLAN
144 M-416 BLDG 134 - LEVEL ONE, TWO, & THREE - ENLARGED PLANS
145 M-417 BLDG 135 - ENLARGED PLANS
146 M-418 BLDG 138, 140, & 187 - ENLARGED PLANS
147 M-419 BLDG 188, 195, 201, 202, 205, & 206 - ENLARGED PLANS
148 M-501 MECHANICAL DETAILS
149 M-502 MECHANICAL DETAILS CONT.
150 M-601 MECHANICAL SCHEDULES
151 M-701 MECHANICAL CONTROLS
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[01] GENERAL
1 GI000 COVER SHEET
2 GI001 SHEET INDEX
3 GI002 GENERAL INFORMATION
[02] CIVIL
4 GS001 GENERAL LAYOUT
5 GS002 EXISTING CONDITIONS WITH EXISTING DUCT BANK ROUTES (VA)
6 GS003 EXISTING CONDITIONS WITH NEW DUCT BANK ROUTES (GIS)
7 GS004 OVERALL SITE AND DEMOLITION PLAN
8 GS005 ENLARGED SITE AND DEMOLITION PLAN 1
9 GS006 ENLARGED SITE AND DEMOLITION PLAN 2
10 GS007 ENLARGED SITE AND DEMOLITION PLAN 3
11 GS008 ENLARGED SITE AND DEMOLITION PLAN 4
12 GS009 ENLARGED SITE AND DEMOLITION PLAN 5
13 GS010 ENLARGED SITE AND DEMOLITION PLAN 6
14 GS011 ENLARGED SITE AND DEMOLITION PLAN 7
15 GS012 ENLARGED SITE AND DEMOLITION PLAN 8
16 GS013 UTILITY PLAN NW QUADRANT
17 GS014 UTILITY PLAN NE QUADRANT
18 GS015 UTILITY PLAN SW QUADRANT
19 GS016 UTILITY PLAN SE QUADRANT
20 GS017 EROSION CONTROL PLAN NW QUADRANT
21 GS018 EROSION CONTROL PLAN NE QUADRANT
22 GS019 EROSION CONTROL PLAN SW QUADRANT
23 GS020 EROSION CONTROL PLAN SE QUADRANT
24 GS021 EROSION CONTROL DETAILS
25 GS022 DETAILS
[03] STRUCTURAL
26 S-001 STRUCTURAL GENERAL NOTES
27 S-201 BLDG 3, 4, 5, 6, & 131 - ROOF PLANS
28 S-202 BLDG 133 - ROOF PLAN
29 S-203 BLDG 134 & 135 - ROOF PLANS
[04] ARCHITECTURAL
30 A-101 BLDG 1, 3, 4 - REFERENCE PLANS
31 A-102 BLDG 6, 7, 9 - REFERENCE PLANS
32 A-103 BLDG 11, 32, 36, 37 - REFERENCE PLANS
33 A-104 BLDG 46, 66, 92 - REFERENCE PLANS
34 A-105 BLDG 131 & 132 - REFERENCE PLANS
35 A-106 BLDG 133 - BASEMENT - REFERENCE PLANS
36 A-107 BLDG 133 - LEVEL ONE - REFERENCE PLANS
37 A-108 BLDG 133 - LEVEL TWO - REFERENCE PLANS
38 A-109 BLDG 133 - LEVEL THREE, & FOUR - REFERENCE PLANS
39 A-110 BLDG 134 - BASEMENT, LEVEL ONE, TWO, & THREE - REFERENCE PLANS
40 A-111 BLDG 135, 138, 140, 187, 188 - REFERENCE PLANS
41 A-112 BLDG 195, 201, 202, 205, 206 - REFERENCE PLANS
42 AE101 BLDG 1 & 3 - ENLARGED PLANS
43 AE102 BLDG 3 & 4 - ENLARGED PLANS
44 AE103 BLDG 6 - LEVEL ONE - ENLARGED PLANS
45 AE104 BLDG 7 - LEVEL ONE & TWO - ENLARGED PLANS
46 AE105 BLDG 9 - ENLARGED PLANS
47 AE106 BLDG 11 & 32 - ENLARGED VIEWS
48 AE107 BLDG 36 & 37 - ENLARGED PLANS
49 AE108 BLDG 46 & 66 - ENLARGED PLANS
50 AE109 BLDG 66, 92, & 131 - ENLARGED PLANS
51 AE110 BLDG 131 - LEVEL ONE, TWO, THREE, & FOUR - ENLARGED PLANS
52 AE111 BLDG 132 & 133 - ENLARGED PLANS
53 AE112 BLDG 133 - BASEMENT - ENLARGED PLANS
54 AE113 BLDG 133 - BASEMENT - ENLARGED PLANS
55 AE114 BLDG 133 - BASEMENT - ENLARGED PLANS
56 AE115 BLDG 133 - LEVEL ONE - ENLARGED PLANS
57 AE116 BLDG 133 - LEVEL ONE - ENLARGED PLANS
58 AE117 BLDG 133 - LEVEL ONE - ENLARGED PLANS
59 AE118 BLDG 133 - LEVEL ONE - ENLARGED PLANS
60 AE119 BLDG 133 - LEVEL TWO - ENLARGED PLANS
61 AE120 BLDG 133 - LEVEL TWO - ENLARGED PLANS
62 AE121 BLDG 133 - LEVEL TWO - ENLARGED PLANS
63 AE122 BLDG 133 - LEVEL THREE - ENLARGED PLANS
64 AE123 BLDG 133 - LEVEL THREE - ENLARGED PLANS
65 AE124 BLDG 133 - LEVEL THREE - SERVER ROOM - ENLARGED PLANS
66 AE125 BLDG 133 - LEVEL THREE - SERVER ROOM - ENLARGED PLANS
67 AE126 BLDG 133 - LEVEL THREE & FOUR - ENLARGED PLANS
68 AE127 BLDG 134 - BASEMENT - ENLARGED PLANS
69 AE128 BLDG 134 - BASEMENT - ENLARGED PLANS
70 AE129 BLDG 134 - LEVEL ONE & TWO - ENLARGED PLANS
71 AE130 BLDG 134 & 135 - ENLARGED PLANS
72 AE131 BLDG 135 - LEVEL ONE & TWO - ENLARGED PLANS
73 AE132 BLDG 135, 138, & 140 - ENLARGED PLANS
74 AE133 BLDG 187 - LEVEL ONE - ENLARGED PLANS
75 AE134 BLDG 188 & 195 - ENLARGED PLANS
76 AE135 BLDG 201, 202, 205, & 206 - ENLARGED PLANS
77 AE601 DOOR SCHEDULE
78 AF711 PARTITION, FINISH SCHEDULES & DETAILS
EHRM INFRASTRUCTURE UPGRADES,
WEST CAMPUS - NORTH CHICAGO
VA PROJECT NUMBER: 556-221-701
VOLUME 1 VOLUME 2
ABBREVIATIONS CODES STANDARDS AND EXECUTIVE ORDERS
4' -0
M
A X
4' -0
M
A X
2' -1
0" M
A X
2' -3
M
IN
1'-6" MIN
1. GENERAL CONTRACTOR TO PROVIDE METAL SUPPORT
BLOCKING FOR ALL WALL MOUNTED ACCESSORIES,
FIXTURES, AND EQUIPMENT.
2. PROVIDE ADA SUPPORT BRACKETS PLACED AT ALL OPEN
COUNTERTOPS @ 36"-48" MAX ON CENTER.
3. SPECIFIED MAXIMUMS ARE MEASURED FROM AFTER
FINISHED FLOOR TO THE OPERABLE PART OF THE FIXTURE.
4. FIXTURES SHOWN ARE REPRESENTATIONAL ONLY. NOT ALL
FIXTURES MAY BE USED. REFER TO SPECIFICATIONS FOR
FIXTURE TYPES USED IN THIS PROJECT.
5. FIXTURES MAY OVERLAP WAINSCOT. WHERE APPLICABLE,
BACKING TO BE PROVIDED AS SHIM FOR FLUSH
APPLICATION. SHIM TO MATCH SCHEDULED WALL FINISH.
6" MAX
9" M
IN
SHOWER
VA TOILET ROOM
TURNING RADIUS
DRINKING
FOUNTAIN
PAPER TOWEL
DISPENSER
SANITARY
NAPKIN
DISPENSER
4' -0
"M A
X
WASTE
RECEPTACLE
LAVATORY
WITH MIRROR
ON CENTER
WALL
4' -0
M
A X
SOAP
DISPENSER
2' -1
0" M
A X
T O
B .O
. R E
F
LE
C T
IV
E
S U
R F
A C
E
3' -4
"M A
X
17 MIN
2' -3
M
IN
3' -0
M
A X
1'-6" MIN
WALL
2' -9
3' -1
/3 2"
M
IN
2'-0" MIN
8" MIN
WALL
LAVATORY
WITH APRON
1' -5
M
A X
1'-6" MIN
URINAL
WALL
1'-5" - 1'-7" (AMBULATORY)
1'-4" - 1'-6" (WHEELCHAIR)
CLEAR FLOOR
5'-6"
CLEAR FLOOR
6'-0"
3'-0" MIN
2' -9
3' -0
1'-0" MIN
3'-6" MIN 1'-0"MAX
4'-6" MIN
1' -5
'-7
1' -6
M
IN
A N
S I I
C C
A
7.
1)
1' -3
M
IN
A D
A /A
B A
2' -9
'-0
WALL
WALL
4' -0
M
A X
WALL HOOK
7' -0
CLOCK
WALL
FINISHED FLOOR
FIRE EXTINGUISHER
CABINET
WEIGHT > 40LBS
FIRE EXTINGUISHER
CABINET
WEIGHT < 40LBS
3' -1
1/
6" M
A X
4' -0
M
A X
TOILET SEAT
COVER
DISPENSER
BABY
CHANGING
STATION
CLEAR FLOOR SPACE
@ WATER CLOSET
5'-6"
2'-6"
4' -0
2'-6"
4' -0
HANDRAILS AND
BUMPERGUARDS
FIXTURE MOUNTING HEIGHTS AND CLEARANCES
18" MIN
M
IN
FRONT APPROACH,
PULL SIDE
36" MIN
M
IN
HINGE APPROACH,
PULL SIDE
HINGE APPROACH,
PULL SIDE
*12" MIN48
M
IN
FRONT APPROACH,
PUSH SIDE
M
IN
HINGE APPROACH,
PUSH SIDE
22" MIN 24" MIN*4
8"
M
IN
LATCH APPROACH,
PULL SIDE
24" MIN*4
2"
M
IN
LATCH APPROACH,
PUSH SIDE
*IF BOTH CLOSER
AND LATCH ARE
PROVIDED
*54" MIN IF CLOSER
IS PROVIDED
*48" IF CLOSER IS
PROVIDED
FRONT APPROACH,
PUSH SIDE
M
IN
42" MIN
DOOR AND FIXTURE CLEARANCES
MATERIALS LEGEND
PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN
VOLUNTARY STANDARD BODIES.
GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS
SPECIFY OTHER CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL
INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
• 2021 INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)
• 2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC) (IF APPLICABLE)
• 2021 NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)
• 2021 NATIONAL FIRE CODES (NFPA)
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
• 2020 VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• 2021 VA PHYSICAL SECURITY & RESILIENCY DESIGN MANUAL
• 2021 INTERNATIONAL MECHANICAL CODE
• 2020 NATIONAL ELECTRICAL CODE (NEC), NFPA 70
• 2021 INTERNATIONAL PLUMBING CODE (IPC)
• 2016 SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.
• 2015 ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS INCLUDING VA SUPPLEMENT, VA BARRIER FREE DESIGN STANDARD (PG-18-13)
• 2017 ANSI ICC A117.1 ACCESIBLE AND USABLE BUILDINGS AND FACILITIES
• 2019 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318-19)
• 2017 STEEL CONSTRUCTION MANUAL (15TH EDITION), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
• ENERGY POLICY ACT OF 2005 (EPACT)
• 2007 DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND
NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.
• 2006 FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
• 2018 EXECUTIVE ORDER 13834: EFFICIENT FEDERAL OPERATIONS
• 2021 THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 010000 OF THE VA MASTER CONSTRUCTION
SPECIFICATION.
• 2019 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1
• 2019 SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT
NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN.
DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES
EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
ASHRAE 90.1 - 2019 EDITION
BUILDING LOCATION: CHICAGO, ILLINOIS
CLIMATE ZONE (TABLE ANNEX 1-1): ZONE 5A
INTERIOR DESIGN CONDITIONS:
THE INTERIOR DESIGN TEMPERATURES FOR HEATING AND COOLING AS DEPICTED IN THE PROJECT DESIGN CONDITIONS SCHEDULE IN THE MECHANICAL CONTROL DRAWINGS SHALL BE THE MAXIMUM
AND MINIMUM VALUES FOR THE ASSOCIATED TEMPERATURE CONTROL ZONES.
BUILDING ENVELOPE REQUIREMENTS (5.5 )
BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 4 (A,B,C)
ROOFS REQUIRED DESIGNED
INSULATION: R-30 c.i. EXISTING METAL BUILDINGS: R-19 + R-11 Ls or R-25 + R-8 Ls EXISTING
ATTIC AND OTHER: R-49 EXISTING
WALLS, ABOVE GRADE
MASS: R-9.5 c.i. EXISTING METAL BUILDING: R-0 + R-15.8 c.i. EXISTING STEEL-FRAMED: R-13 + R-7.5 c.i. EXISTING WOOD-FRAMED AND OTHER: R-13 + R-3.8 c.i. or R-20 EXISTING
WALL, BELOW GRADE
BELOW-GRADE WALL: R-7.5 c.i. EXISTING
FLOORS
MASS: R-14.6 c.i. EXISTING
STEEL-FRAMED: R-30 EXISTING
WOOD-FRAMED AND OTHER: R-30 EXISTING
SLAB-ON-GRADE FLOORS
UNHEATED SLABS: R-15 for 24 in. EXISTING HEATED SLABS: R-20 for 24 in. EXISTING
OPAQUE DOORS
SWINGING: U-0.370 EXISTING
NONSWINGING: U-0.310 EXISTING
FENESTRATION (TABLE 5.5-4):
VERTICAL FENESTRATION, U-FACTOR
FIXED: U-0.36 EXISTING
OPERABLE: U-0.45 EXISTING
ENTRANCE DOOR: U-0.63 EXISTING
DEFINITIONS
c.i = CONTINUOUS INSULATION Ls = LINEAR SYSTEM
NR = NO (INSULATION) REQUIREMENT
NO EXTERIOR IMPROVEMENTS INCLUDED IN THE SCOPE OF THIS PROJECT.
ENERGY REQUIREMENTS
N
1. DRAWINGS ARE PART OF A COMPLETE DOCUMENTS SET. CONTRACTOR SHALL
CONFIRM ALL ITEMS REQUIRED BASED UPON THE OVERALL DESIGN INTENT OF THE
ENTIRE DOCUMENT SET.
2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, PRIOR TO BEGINNING ANY
WORK, TO CONFIRM THE ACCURACY OF THE DRAWINGS AND REPORT ANY
DISCREPANCIES TO THE ARCHITECT. DO NOT SCALE THE DRAWINGS. FIELD VERIFY
ALL DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS PROJECT SHALL BE KEPT
CLEAN AND FREE OF OBSTRUCTIONS AT ALL TIMES.
4. ERECT BARRICADES AND WARNING SIGNS TO DIVERT AND WARN PASSERS-BY OF THE
CONSTRUCTION WORK. PROVIDE DUST PROOFING ENCLOSURES TO SEPARATE WORK
AREAS FROM THE EXISTING FACILITIES.
5. ALL TRASH AND DEBRIS TO BE REMOVED ON A DAILY BASIS.
6. PROVIDE PROTECTION FOR ALL EXISTING SURFACES AND CONDITIONS TO REMAIN IN
PLACE DURING THE SCOPE OF WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND
REPAIR ANY DAMAGE TO ADJACENT FINISHES TO MATCH EXISTING.
7. ANY DAMAGE CAUSED TO THE BUILDING OR OWNER EQUIPMENT SHALL BE REPAIRED
OR REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL COST TO THE
OWNER.
8. COVER ALL RETURN AIR GRILLES WITHIN THE AREA OF CONSTRUCTION TO PREVENT
PARTICULATE MATERIAL FROM EXHAUSTING INTO SURROUNDING SPACES.
9. APPROPRIATE LIGHT FIXTURES SHALL BE TEMPORARILY SUSPENDED TO PROVIDE
ADEQUATE LIGHTING LEVELS FOR CONSTRUCTION.
10. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO COORDINATE WITH OTHER
DISCIPLINES TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS. DRAWINGS, AS A
WHOLE, REPRESENT A COMPLETE SET AND DEPICT REQUIREMENTS FOR COMPLETE
AND OPERATIONAL SYSTEMS. INDIVIDUAL DRAWINGS MAY NOT DEPICT COMPLETE AND
ACCURATE INFORMATION TO COORDINATE COMPLETE AND OPERATIONAL SYSTEMS,
BUT DO SO AS AN ENTIRE DOCUMENT TO BE REFERENCED WITH OTHER INDIVIDUAL
DRAWINGS. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO REFERENCE
OTHER SHEETS AND SPECIFICATIONS AS AN ENTIRE SET OF CONSTRUCTION
DOCUMENTS THAT REFLECT WORK REQUIRED TO ACHIEVE A COMPLETE AND
OPERATIONAL GOAL. LACK OF COORDINATION AND REVIEW OF DRAWINGS AND
SPECIFICATIONS AS AN ENTIRE DOCUMENT TO INSTALL COMPLETE AND OPERATIONAL
SYSTEMS, BEING OBVIOUS AND TYPICAL INDUSTRY STANDARD, IDENTIFIED IN THE
DRAWINGS AND SPECIFICATIONS, SHALL NOT BE IN ANY WAY AN ADDITIONAL COST TO
THE GOVERNMENT.
11. CONTRACTOR SHALL SUBMIT A REQUEST, IN WRITING, TO INTERRUPT ANY SUCH
SERVICES TO COR (CONTRACTING OFFICER’S REPRESENTATIVE) 48 HOURS IN
ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE,
EXACT TIME OF, AND APPROXIMATE DURATION OF SUCH INTERRUPTION. MAJOR
INTERRUPTIONS OF ANY SYSTEM MUST BE REQUESTED, IN WRITING, AT LEAST 60
CALENDAR DAYS PRIOR TO THE DESIRED TIME AND SHALL BE PERFORMED AS
DIRECTED BY THE COR. MAJOR INTERRUPTIONS SHALL BE COORDINATED WITH OTHER
MAJOR INTERRUPTIONS AND MAY NOT BE SCHEDULED FOR ONE DISCIPLINE MORE
THAN TWICE THROUGHOUT THE OVERALL CONSTRUCTION SCHEDULE UNLESS
REQUESTED IN WRITING AND APPROVED BY THE COR. CONTRACTOR WILL BE ADVISED,
IN WRITING, OF APPROVAL OF REQUEST, OR OF WHICH OTHER DATE AND/OR TIME
SUCH INTERRUPTION WILL CAUSE THE LEAST INCONVENIENCE TO OPERATIONS OF
THE MEDICAL CENTER. INTERRUPTION TIME APPROVED BY THE MEDICAL CENTER MAY
OCCUR AT TIMES OTHER THAN CONTRACTOR'S NORMAL WORKING HOURS. SCHEDULE
INTERRUPTION MAY BE ON WEEKENDS OR LATE HOURS AND MAY NOT BE AN
ADDITIONAL COST TO THE GOVERNMENT. COORDINATE ALL INTERRUPTIONS THAT MAY
AFFECT THE NORMAL OPERATION OF THE FACILITY WITH THE COR WHEN SUBMITTING
THE CONSTRUCTION SCHEDULE OR UPDATES TO THE CONSTRUCTION SCHEDULE.
12. NO ASBESTOS CONTAINING MATERIALS ARE TO BE USED ON THIS PROJECT. SPUR
DESIGN, THE A/E OF RECORD, CAN CERTIFY THAT NO ASBESTOS CONTAINING
BUILDING MATERIALS (ACBM) OR LEAD BASED PAINT (LBP) PRODUCTS WERE
DESIGNED/SPECIFIED AS BUILDING MATERIAL IN ANY OF THE CONSTRUCTION
DOCUMENTS.
13. PROVIDE A CLEAN AGENT FIRE EXTINGUISHER LOCATED IN A CABINET AND INSTALLED
AT EACH TELECOMMUNICATION ROOM (TR) AT A LOCATION NO GREATER THAN 75 FEET
AWAY. PROVIDE ADDITIONAL SIGNAGE TO INDICATE THAT FIRE EXTINGUISHER IS TO BE
USED FOR TR ONLY.
GENERAL NOTES
AREA NAME
150 SF
A101
A101
SIM
A
00.0
A101
1 1
A101
LEVEL NAME
00'-00"
00'-00" 4B
3A
FIBERGLASS BATT
INSULATION
RIGID INSULATION
CONCRETE / PRECAST
CONCRETE
EARTH / SOIL
SAND, EIFS FINISH, OR
PLASTER FINISH
GYPSUM BOARD FINISH
BRICK
CONCRETE MASONRY
UNIT
STONE / CAST STONE
GYPSUM BOARD SECTION
EXTERIOR SHEATHING
BOARD SECTION
PLYWOOD SECTION
ROOM NAME
000A150 SF/
PROGRAMMED
AREA
/1 A101
X0000
6"
3' -0
M
A X
ROOM TAG
AREA TAG
SPECIALTY EQUIPMENT TAG
DOOR TAG
KEYED NOTE TAG
WALL TAG
WINDOW TAG
A101
SIM
A101
SIM
A
ACB ACOUSTIC CEILING BAFFLE
ACP ACOUSTIC CEILING PANEL
ACST ACOUSTIC
ADA AMERICANS WITH DISABILITIES ACT
ACT ACOUSTICAL CEILING TILE
ADDL ADDITIONAL
ADDN ADDITION
ADJ ADJACENT, ADJOINING, OR
ADJUSTABLE
ADMIN ADMINISTRATION
AE ARCHITECT/ENGINEER
AF ACCESS FLOORING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIA AMERICAN INSTITUTE OF
ARCHITECTS
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINIUM (TRIM)
AMT AMOUNT
APPROX APPROXIMATE
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
AT ACOUSTIC CEILING TILE
AVG AVERAGE
B
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BOS BOTTOM OF STEEL
BOT BOTTOM
BRKT BRACKET
BTWN BETWEEN
C
CAB CABINET
CAV CAVITY
CBB CONCRETE BACKER BOARD
CD CONSTRUCTION DOCUMENTS
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CH BD CHALK BOARD
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CP CONTRACTOR PROVIDED
CP/CI CONTRACTOR PROVIDED /
CONTRACTOR INSTALLED
CPT CAROET/CARPET TILE
CS CONCRETE SEALED
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTR CENTER
CU FT CUBIC FEET
D
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
DWG DRAWING
DWP DIMENSIONAL WALL PANEL
E
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPY EPXOY FLOORING
EQ EQUAL
ETR EXISTING TO REMAIN
EX EXISTING
EXP EXPOSED
EXT EXTERIOR
F
FAB FABRIC
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FP FIRE PROTECTION
FR FIRE RESISTANT
FRP FIRE RATED PLYWOOD
FT FEET
FTG FOOTING
FV FIELD VERIFY
FWC FABRIC WALL COVERING
G
GDR GUARDRAIL
GL GLASS/GLAZING
GRAN GRANITE
GR FL GROUND FLOOR
GT GROUT
GSM GALVANIZED SHEET METAL
GYP BD GYPSUM BOARD
H
HDW HARDWARE
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HANDRAIL
HT HEIGHT
I
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J
J-BOX JUNCTION BOX
L
LAV LAVATORY
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIN LINEAR
LN LINOLEUM
LOC LOCATION
LT LIGHT
LVR LOUVER
LVT LUXURY VINYL TILE
M
MAT CARPET MAT / WALK-OFF MAT
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODIFY
MTG MOUNTING
MTL METAL
MVBL MOVABLE
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
OTS OPEN TO STRUCTURE
P
P PAINT
PA PUBLIC ADDRESS
PBD PARTICLE BOARD
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PNL PANEL
PR PAIR
PRB PROFILE BASE
PRKG PARKING
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PORCELAIN TILE
PWR POWER
Q
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QTY QUANTITY
REFERENCE SYMBOLS IDENTIFICATION TAGS
NOTE: NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR THIS PROJECT.
GRID HEAD AND
LINE
LEVEL INDICATOR
MATCH LINE AND
VIEW REFERENCE
NORTH ARROW W/
PROJECT NORTH
SPOT ELEVATION
DETAIL
SECTION
**48" MIN IF BOTH CLOSER
AND LATCH PROVIDED
WALL
SECTION
BUILDING
SECTION
DETAIL
ELEVATION
INTERIOR
ELEVATION
BUILDING
ELEVATION
1 1
6'- 0"
5'- 6"
BARIATRIC TOILET ROOM
TURNING RADIUS
CLEAR FLOOR SPACE
@ ADA LAVATORY
CLEAR FLOOR SPACE @ ADA
DRINKING FOUNTAIN
4 7/256"
6 1/32"
3"
7/
6"
1' -6
/3
2"
6" MAX
7" - 9" 11" MIN
17" - 25"
M
IN
6' -0
(ANSI ICC A117.1)
39"- 41"
(A N
S I I
C C
A
7.
1)
M
IN
(A N
S I I
C C
A
7.
1)
1"
3' -5
/2
M
A X
4' -1
1/
6" M
A X
R
RAF RESILIENT ATHETIC FLOORING
RB RUBBER BASE/RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RES RESINOUS FLOORING
RES-W RESINOUS / EPOXY WALL / CEILING
RF RUBBER FLOORING
RFG ROOFING
RM ROOM
RO ROUGH OPENING
RP RESIN PANEL
RSF RESILIENT SHEET FLOORING
RV ROOF VENT
RWC RIGID VINYL WALLCOVERING
S
SC SEALED CONCRETE
SDT STATIC DISSIPATIVE FLOORING/TILE
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT (FEET)
SGL SINGLE
SIM SIMILAR
SJ SCORED JOINT
SLNT SEALANT
SM SHEET METAL
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SOLID SURFACE
ST STONE
STD STANDARD
STOR STORAGE
SV SHEET VINYL (ROLLED OR TILE)
T
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZO
TOF TOP OF FOOTING/ FOUNDATION
TOM TOP OF MASONRY
TOS TOP OF SLAB/ STEEL
TE TELECOMMUNICATIONS ENCLOSURE
TR TELECOMMUNICATIONS ROOM
U
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
V
VAR VARIES
VC VA PROVIDED / CONTRACTOR
INSTALLED
VCT VINYL COMPOSITION TILE
VFAT VINYL FACED ACOUSTICLAL TILE
VP VENEERED PLASTER
VT VINYL TILE
VV VA PROVIDED / VA INSTALLED
VWC VINYL WALLCOVERING
VWF VINYL WALL FABRIC
W
W/ WITH
W/O WITHOUT
W/C WATER CLOSET
WC WHEELCHAIR
WD WOOD
WFAB WALL FABRIC
WPM WATERPROOF MEMBRANE
WSF WELDED SHEET FLOOR
X
X BRACE CROSS BRACE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023
MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023
ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023
CIVIL ENGINEER
OLSSON
550 E. ST. LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2517 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
STRUCTURAL ENGINEER
STAND (SEI)
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT (RSH)
1139 OLIVE ST., STE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATION
ASPEN COMMUNICATIONS
7 KIJI-DAVA CIRCLE, STE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FIRE PROTECTION ENGR
POOLE FIRE PROTECTION
19910 WEST 161ST ST.,
OLATHE, KANSAS 66062
(913) 829-8690
/6
/2
:4
:5
A
M
GENERAL INFORMATION
BAB 3 OF 348AJS
ISSUE FOR BID & CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES, WEST CAMPUS -
NORTH CHICAGO
12/08/2022
556-21-701
3001 GREEN BAY ROAD
NORTH CHICAGO, ILLINOIS 60064
GI002
SPUR #: 2113
ISSUED FOR BID & CONSTRUCTION
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
FULLY SPRINKLERED
STAMP:
Drawing Number
Building Number
/1
/2
1:
P
M
AMA 348CRW
EHRM INFRASTRUCTURE
UPGRADES, WEST CAMPUS -
NORTH CHICAGO
12/08/2022
556-221-701
CAPTAIN JAMES A. LOVELL FHCC
3001 GREEN BAY ROAD
NORTH CHICAGO, ILLINOIS 60064
SPUR #: 2113
No. REVISION DESCRIPTION DATE
CIVIL ENGINEER
OLSSON
550 E. ST. LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2519 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
STRUCTURAL ENGINEER
STAND (SEI)
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
INDUSTRIAL HYGENIST
RIVERFRONT (RSH)
1139 OLIVE ST., STE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATION
ASPEN COMMUNICATIONS
7 KIJI-DAVA CIRCLE, STE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
FIRE PROTECTION ENGR
POOLE FIRE PROTECTION
19910 WEST 161ST ST.,
OLATHE, KANSAS 66062
(913) 829-8690
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C O
N
TR
O
LL
E D
U N
C
LA
S S
IF
IE
D
IN
FO
R
M A
TI
O
N (C
U I)
ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023
MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023
ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023
www.olsson.comTEL 417.890.8802
550 St. Louis St.
Springfield, MO 65806 Olsson # 021-06005
Olsson, Inc. Engineering IL State Cert. of Authority 184.003968-0010
GIS PROVIDED BACKGROUND
SHOWN ON THIS SHEET
GS001
GENERAL LAYOUT PLAN
DEMOLITION NOTES: PAVEMENT MARKING NOTES:
GENERAL NOTES:
CALL 811 SEVENTY-TWO HOURS PRIOR TO
DIGGING, GRADING OR EXCAVATING FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
Know what's below.
before you dig.CallR
LEGEND
BUILDING SCOPE TABLE:
SURVEY NOTES:
exp. 11/30/2023
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
FULLY SPRINKLERED
STAMP:
Drawing Number
Building Number
/1
/2
1:
P
M
AMA 348CRW
EHRM INFRASTRUCTURE
UPGRADES, WEST CAMPUS -
NORTH CHICAGO
12/08/2022
556-221-701
CAPTAIN JAMES A. LOVELL FHCC
3001 GREEN BAY ROAD
NORTH CHICAGO, ILLINOIS 60064
SPUR #: 2113
No. REVISION DESCRIPTION DATE
CIVIL ENGINEER
OLSSON
550 E. ST. LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2519 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
STRUCTURAL ENGINEER
STAND (SEI)
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
INDUSTRIAL HYGENIST
RIVERFRONT (RSH)
1139 OLIVE ST., STE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATION
ASPEN COMMUNICATIONS
7 KIJI-DAVA CIRCLE, STE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
FIRE PROTECTION ENGR
POOLE FIRE PROTECTION
19910 WEST 161ST ST.,
OLATHE, KANSAS 66062
(913) 829-8690
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C O
N
TR
O
LL
E D
U N
C
LA
S S
IF
IE
D
IN
FO
R
M A
TI
O
N (C
U I)
ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023
MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023
ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023
www.olsson.comTEL 417.890.8802
550 St. Louis St.
Springfield, MO 65806 Olsson # 021-06005
Olsson, Inc. Engineering IL State Cert. of Authority 184.003968-0010
GS002
EXISTING CONDITIONS WITH EXISTING
DUCT BANK ROUTES (VA)
GENERAL NOTES:
CALL 811 SEVENTY-TWO HOURS PRIOR TO
DIGGING, GRADING OR EXCAVATING FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
Know what's below.
before you dig.CallR
(VA PROVIDED SURVEY)
VA PROVIDED BACKGROUND
SHOWN ON THIS SHEET
LEGEND
GENERAL NOTES:
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
FULLY SPRINKLERED
STAMP:
Drawing Number
Building Number
/1
/2
1:
P
M
AMA 348CRW
EHRM INFRASTRUCTURE
UPGRADES, WEST CAMPUS -
NORTH CHICAGO
12/08/2022
556-221-701
CAPTAIN JAMES A. LOVELL FHCC
3001 GREEN BAY ROAD
NORTH CHICAGO, ILLINOIS 60064
SPUR #: 2113
No. REVISION DESCRIPTION DATE
CIVIL ENGINEER
OLSSON
550 E. ST. LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2519 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
STRUCTURAL ENGINEER
STAND (SEI)
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
INDUSTRIAL HYGENIST
RIVERFRONT (RSH)
1139 OLIVE ST., STE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATION
ASPEN COMMUNICATIONS
7 KIJI-DAVA CIRCLE, STE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
FIRE PROTECTION ENGR
POOLE FIRE PROTECTION
19910 WEST 161ST ST.,
OLATHE, KANSAS 66062
(913) 829-8690
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C O
N
TR
O
LL
E D
U N
C
LA
S S
IF
IE
D
IN
FO
R
M A
TI
O
N (C
U I)
ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023
MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023
ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023
www.olsson.comTEL 417.890.8802
550 St. Louis St.
Springfield, MO 65806 Olsson # 021-06005
Olsson, Inc. Engineering IL State Cert. of Authority 184.003968-0010
GIS PROVIDED BACKGROUND
SHOWN ON THIS SHEET
GS003
EXISTING CONDITIONS WITH NEW
DUCT BANK ROUTES (GIS)
CALL 811 SEVENTY-TWO HOURS PRIOR TO
DIGGING, GRADING OR EXCAVATING FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
Know what's below.
before you dig.CallR
(GIS SURVEY PLUS GIS AERIAL)
LEGEND
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
FULLY SPRINKLERED
STAMP:
Drawing Number
Building Number
/1
/2
1:
P
M
AMA 348CRW
EHRM INFRASTRUCTURE
UPGRADES, WEST CAMPUS -
NORTH CHICAGO
12/08/2022
556-221-701
CAPTAIN JAMES A. LOVELL FHCC
3001 GREEN BAY ROAD
NORTH CHICAGO, ILLINOIS 60064
SPUR #: 2113
No. REVISION DESCRIPTION DATE
CIVIL ENGINEER
OLSSON
550 E. ST. LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2519 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
STRUCTURAL ENGINEER
STAND (SEI)
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
INDUSTRIAL HYGENIST
RIVERFRONT (RSH)
1139 OLIVE ST., STE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATION
ASPEN COMMUNICATIONS
7 KIJI-DAVA CIRCLE, STE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
FIRE PROTECTION ENGR
POOLE FIRE PROTECTION
19910 WEST 161ST ST.,
OLATHE, KANSAS 66062
(913) 829-8690
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C O
N
TR
O
LL
E D
U N
C
LA
S S
IF
IE
D
IN
FO
R
M A
TI
O
N (C
U I)
ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023
MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023
ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023
www.olsson.comTEL 417.890.8802
550 St. Louis St.
Springfield, MO 65806 Olsson # 021-06005
Olsson, Inc. Engineering IL State Cert. of Authority 184.003968-0010
GIS PROVIDED BACKGROUND
SHOWN ON THIS SHEET
GS004
OVERALL SITE AND DEMOLITION PLAN
CALL 811 SEVENTY-TWO HOURS PRIOR TO
DIGGING, GRADING OR EXCAVATING FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
Know what's below.
before you dig.CallR
SURVEY NOTES:
SEE ENLARGED SITE
AND DEMOLITION PLAN 8
(SHEET GS012)
SEE ENLARGED SITE
AND DEMOLITION PLAN 7
(SHEET GS011)
SEE ENLARGED SITE
AND DEMOLITION PLAN 6
(SHEET GS010)
SEE ENLARGED SITE
AND DEMOLITION PLAN 5
(SHEET GS009
SEE ENLARGED SITE
AND DEMOLITION PLAN 1
(SHEET GS005)
SEE ENLARGED SITE
AND DEMOLITION PLAN 2
(SHEET GS006)
SEE ENLARGED SITE
AND DEMOLITION PLAN 3
(SHEET GS007)
SEE ENLARGED SITE
AND DEMOLITION PLAN 4
(SHEET GS008)
ENLARGED SITE AND DEMOLITION PLAN 1
GS005
ISSUED FOR BID & CONSTRUCTION
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
FULLY SPRINKLERED
STAMP:
Drawing Number
Building Number
/1
/2
1:
P
M
AMA 348CRW
EHRM INFRASTRUCTURE
UPGRADES, WEST CAMPUS -
NORTH CHICAGO
12/08/2022
556-221-701
CAPTAIN JAMES A. LOVELL FHCC
3001 GREEN BAY ROAD
NORTH CHICAGO, ILLINOIS 60064
SPUR #: 2113
No. REVISION DESCRIPTION DATE
CIVIL ENGINEER
OLSSON
550 E. ST. LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
2519 MADISON AVE. STE 100
KANSAS CITY, MO 64108
(913) 369-7200
STRUCTURAL ENGINEER
STAND (SEI)
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
INDUSTRIAL HYGENIST
RIVERFRONT (RSH)
1139 OLIVE ST., STE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATION
ASPEN COMMUNICATIONS
7 KIJI-DAVA CIRCLE, STE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
FIRE PROTECTION ENGR
POOLE FIRE PROTECTION
19910 WEST 161ST ST.,
OLATHE, KANSAS 66062
(913) 829-8690
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C O
N
TR
O
LL
E D
U N
C
LA
S S
IF
IE
D
IN
FO
R
M A
TI
O
N (C
U I)
ARCH REG. SETH CAVIN, #001.023503 EXP. 11/30/2023
MECH REG. ROSS MYLES, #062.071715 EXP. 11/30/2023
ELEC REG. BEN NOE, #062.072296 EXP. 11/30/2023
www.olsson.comTEL 417.890.8802
550 St. Louis St.
Springfield, MO 65806 Olsson # 021-06005
Olsson, Inc. Engineering IL State Cert. of Authority 184.003968-0010
GIS PROVIDED BACKGROUND
SHOWN ON THIS SHEET
CALL 811 SEVENTY-TWO HOURS PRIOR TO
DIGGING, GRADING OR EXCAVATING FOR THE
MARKING OF UNDERGROUND MEMBER UTILITIES.
Know what's below.
before you dig.CallR
FOR LEGEND
SEE SHEET GS008
SURVEY NOTES:
CAUTION REGARDING EXISTING UTILITIES
LEGEND
GENERAL NOTES:
KEYNOTES:
ENLARGED SITE AND DEMOLITION PLAN 2
GS006
ISSUED FOR BID & CONSTRUCTION
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
FULLY SPRINKLERED
STAMP:
Drawing Number
Building Number
/1
/2
1:
P
M
AMA 348CRW
EHRM INFRASTRUCTURE
UPGRADES, WEST CAMPUS -
NORTH CHICAGO
12/08/2022
556-221-701
CAPTAIN JAMES A. LOVELL FHCC
3001 GREEN BAY ROAD
NORTH CHICAGO, ILLINOIS 60064
SPUR #: 2113
No. REVISION DESCRIPTION DATE
CIVIL ENGINEER
OLSSON
550…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .