S02 - Att12 - Drawings 9of11 - Electrical.pdf
PDF 39 MB Posted
- Attached to
- Construct EHRM Infrastructure Upgrades - Philadelphia, PA Federal contract opportunity
- Solicitation number
- 36C77626R0063_1
About this file
This file is an electrical drawing set for a federal construction project. The document is part of the EHRM Infrastructure Upgrades project at the Philadelphia VA Medical Center (CMCVAMC), located at 3900 Woodland Avenue, Philadelphia, PA 19104. The project number is 642-22-700, issued on January 16, 2026, as 100% Bid Documents for a fully sprinklered facility. The drawings were prepared by the Architect of Record (INTROBA and HFS Company) and cover Building 1's electrical systems across multiple floors.
The electrical drawings establish comprehensive infrastructure requirements including security systems (access control, alarm systems, security cameras), fire alarm systems, power distribution equipment, lighting controls, telecommunications coordination, and equipment mounting specifications. Key systems include card readers and pin pads mounted at 48 inches above finished floor, fire alarm panels and devices, electrical distribution transformers, motor starters, variable frequency drives (VFDs), and surge protection devices. Device mounting heights are specified with precise standards for above-counter installations and bathroom receptacle placement with ground fault protection requirements. The drawings detail conduit routing from basement electrical rooms (A001E and B022A) serving as primary distribution points with vertical risers to upper floors. Telecommunications rooms (TRs) at A001D, B022B, A207, B228B, A361, B317A, A455A, A502, A601, A741, A843A, and A932 receive dedicated emergency and normal power feeds. The project incorporates phasing protocols for IT equipment installation and removal, requiring coordination with the owner and construction manager to minimize service disruption, particularly in patient care areas scheduled for premium-time work (nights/weekends). Demolition notes address removal of existing equipment, including outdated UPS systems and panels, with requirements for proper disposal of hazardous materials such as PCB-containing ballasts and mercury lamps.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CARD READER WITH PIN PAD WALL MOUNT AT +48" A.F.F.
SECURITY ALARM SYSTEMS
ACCESS CONTROL SYSTEMS
SECURITY CAMERA
PUSHBUTTON : +48" A.F.F. OR AS NOTED
KEYSWITCH : WALL MOUNT AT +48" A.F.F.
CARD READER : WALL MOUNT AT +48" A.F.F.
POWER SUPPLYPS
CR
CRP
KS
CAM 360 DEGREE SECURITY CAMERA
REX REQUEST TO EXIT
ELECTRICAL EQUIPMENT
DISCONNECT SWITCHT
NOTE: THE ACTUAL SIZE OF EQUIPMENT IS SHOWN ON THE DRAWINGS AND MAY
DIFFER FROM WHAT IS SHOWN BELOW.
ELECTRICAL DISTRIBUTION EQUIPMENT
TYPE AS INDICATED ON DRAWINGS
TRANSFORMER
FUSED DISCONNECT
SWITCH
MOTOR STARTER
VFD MOTOR STARTER
SPD SURGE PROTECTION DEVICE
M ELECTRICAL METER
START/STOP,
MOMENTARY CONTACT
PUSHBUTTON SWITCH
NOTE 4,5
NOTE 1 NOTE 2
SINK OR
BASIN
FINISHED FLOOR
DEVICE MOUNTING NOTES:
1.
2.
3.
4.
COORDINATE ABOVE COUNTER ("AC") WIRING DEVICES WITH
CASEWORK, COUNTERS AND BACKSPLASH SUCH THAT THE
DEVICES AND RECEPTACLES ARE LOCATED AT +42" AFF OR 6"
ABOVE THE COUNTERTOP OR BACKSPLASH, WHICHEVER IS
HIGHER. WIRING DEVICES IDENTIFIED AS "HZ" SHALL BE
HORIZONTALLY-INSTALLED WITHIN THE BACKSPLASH OR
APPLICABLE MOUNTING MEDIUM AND VERTICALLY-CENTERED.
ALL RECEPTACLES INSTALLED WITHIN 6'-0" OF THE EDGE OF ANY
SINK OF BASIN SHALL HAVE GFI PROTECTION. DO NOT INSTALL
RECEPTACLES WITHIN 12" OF THE EDGE OF A SINK OR BASIN.
COORDINATE WITH THE TELECOMMUNICATIONS DRAWINGS TO
ENSURE THAT A RECEPTACLE IS INSTALLED WITHIN 18"
HORIZONTAL TO ALL SIGNAL AND DATA DEVICE LOCATIONS.
SWITCHES AND OTHER FLUSH WALL-MOUNTED DEVICES SHALL BE
MOUNTED WITHIN 24" OF DOORFRAME. COORDINATE WITH
ARCHITECTURAL DRAWINGS FOR DOORS WITH SIDELITES. WHERE
DEVICES ARE TO BE INSTALLED ON A WALL ADJACENT- AND
PERPENDICULAR- TO THE DOORFRAME, MOUNT THE DEVICE 12"
BEYOND THE DOOR SWING EXTENT. COORDINATE ROUGH-IN
LOCATIONS WITH DIV. 27 AND 28 DEVICES.
NOTE 3
NOTE 6
C L
SEE FIRE ALARM GENERAL NOTES
C L
S T
U
O N
TV
FCR AA
HZM
F
TYPICAL DEVICE MOUNTING HEIGHTS:
A
DSP
FZ
REF
MW
VM
IM
ABOVE COUNTER
SEE "DEVICE MOUNTING NOTES" NOTE 1
DISPOSAL, +24" AFF
FREEZER, +24" AFF
REFRIGERATOR, +24" AFF
MICROWAVE, +6" ABOVE MICROWAVE SHELF
VENDING MACHINE, +24" AFF
ICE MACHINE, +24" AFF
DEVICE BACKBOXES SHOWN
FOR REFERENCE ONLY
5.
6.
COORDINATE MOUNTING LOCATION WITH OTHER TRADES
TO ENSURE A COMMON MOUNTING HEIGHT, UNIFORM
SPACING AND AESTHETICALLY-PLEASING APPEARANCE.
WIRING DEVICES MOUNTING HEIGHT INDICATED IN LEGEND
AND ON THE DRAWINGS SHALL BE THE DISTANCE
MEASURED FROM THE CENTER OF THE DEVICE TO THE
FINISHED FLOOR.
TYPICAL WIRING DEVICE MOUNTING DETAIL (NOT TO SCALE)
1. THE FIRE ALARM CONTENT SHOWN ON THE DRAWINGS REPRESENTS A
SCHEMATIC LAYOUT WITH CERTAIN SPECIFIC REQUIREMENTS IDENTIFIED.
PROVIDE ENGINEERED SHOP DRAWINGS (SIGNED AND SEALED) AND FINAL
INSTALLATION IN COMPLIANCE WITH THESE FIRE ALARM GENERAL NOTES,
THE SCHEMATIC FIRE ALARM CONTENT AND REQUIREMENTS SET FORTH BY
THESE DRAWINGS, AND ANY ADDITIONAL REQUIREMENTS ESTABLISHED BY
CODE, THE AUTHORITIES HAVING JURISDICTION, OR UNFORESEEN
CONDITIONS. FURNISH THESE ENGINEERED FIRE ALARM SHOP DRAWINGS
TO BOTH THE AUTHORITIES HAVING JURISDICTION (AHJ) AND THE
ARCHITECT FOR REVIEW.
2. PROVIDE ENGINEERED FIRE ALARM SHOP DRAWINGS THAT INCLUDE ALL
DEVICES, EQUIPMENT, AND APPURTENANCES AS REQUIRED BY APPLICABLE
CODES OR AS NECESSARY TO FOR A COMPLETE, FUNCTIONAL, FIRE ALARM
SYSTEM INCLUDING INTERFACES WITH OTHER SYSTEMS AS DESCRIBED IN
THE CONSTRUCTION DOCUMENTS.
3. SPECIAL REQUIREMENTS FOR CIRCUIT BREAKERS PROVIDING
OVERCURRENT PROTECTION TO FIRE ALARM SYSTEM CLASS I CIRCUITS:
PROVIDE VISUALLY-DISTINGUISHABLE RED CIRCUIT BREAKERS WITH LOCK-
ON DEVICE AND 'FIRE ALARM SYSTEM' LABEL.
FIRE ALARM SYSTEM
FIRE ALARM
CONTROL PANEL
FIRE ALARM
ANNUNCIATOR PANEL
MANUAL PULL STATION
GENERATOR
ANNUNCIATOR PANEL
HORN
WALL-MOUNTED
HORN/STROBE
WALL-MOUNTED
STROBE
WALL-MOUNTED
HEAT DETECTOR
FIXED TEMPERATURE
HEAT DETECTOR
RATE OF RISE
SMOKE DETECTOR
PHOTOELECTRIC TYPE
FACP
SD
FIRE ALARM BELL
SPRINKLER FLOW SWITCH
SPRINKLER TAMPER SWITCH
SPRINKLER SOLENOID VALVE
PRESSURE SWITCH
DOOR HOLDER
EOL RESISTOR
CONTROL RELAY
ADDRESSABLE
MONITOR MODULE
ADDRESSABLE
SMOKE DAMPER
DUCT-MOUNTED
SMOKE DETECTOR
PHOTOELECTRIC TYPE;
CLEAN AGENT HEAD;
DATA CENTER SMOKE
DETECTOR
FAAP
GAP
F
F
F#
F#
HF
HR
B
FW
FT
FV
FP
DH
FR
FM
SD
DS
F
CA
S
PLAN MARK
EQUIPMENT NUMBER
SHEET NUMBER
LINE TYPE LEGEND
DRAWING REFERENCES
NEW WORK BY THIS CONTRACTOR
(DARK, SOLID LINE)
EXISTING TO REMAIN OR NEW WORK BY OTHERS
(LIGHT, SOLID LINE)
EXISTING TO BE REMOVED BY THIS CONTRACTOR
(DARK, DASHED LINE, DEMOLITION PLANS)
NORTH ARROW
PLAN DETAIL REFERENCE TITLE
KEYED NOTE DESIGNATION
PLAN MARK
EQUIPMENT NUMBER
EQUIPMENT DESIGNATION REFER TO MEP
SCHEDULE FOR CIRCUITING AND DEVICE
REQUIREMENTS AND FLOOR PLANS FOR
LOCATIONS
NOTE: WHEN THIS SYMBOL IS USED, IT
MEANS REFER TO MEP SCHEDULE.
ENLARGED PLAN REFERENCE
PLAN MARK
SHEET NUMBER
A101
SIM
AHU
TITLE
SCALE
PLAN
NORTH
TRUE
NORTH
MATCHLINE
1 REVISION TAG
EQUIPMENT
TAG
1. REFER TO THE MEP COORDINATION SCHEDULE SHOWN ON
E6.11 FOR MECHANICAL EQUIPMENT AND PLUMBING
EQUIPMENT REQUIREMENTS. EQUIPMENT TYPE
EQUIPMENT NUMBER
SAMPLE
EQUIPMENT
MEP COORDINATION
AHU
WIRING DEVICES
RECEPTACLES (NEMA 5-20 R) - UNLESS OTHERWISE INDICATED,
ALL RECEPTACLES ARE TO BE UL LISTED AS HOSPITAL GRADE
RECESSED SIMPLEX GFI RECESSED DUPLEX
RECESSED DUPLEX RECESSED QUAD
OVERHEAD CEILING RECEPTACLE
REFER TO ELECTRICAL NEW WORK PLANS
FOR NEMA CONFIGURATION
RECESSED JBOX
TELEVISION RECEPTACLE
PROVIDE COMPARTMENTALIZED BACKBOX WITH
DUPLEX RECEPTACLE WITHIN ONE OF THE ISOLATED
COMPARTMENTS
DUPLEX CEILING RECEPTACLE
FLUSH-MOUNT WITHIN CEILING. REFER TO
TELECOMMUNICATIONS NEW WORK PLANS FOR
SIGNAL REQUIREMENTS
FLOORBOX
QUAD RECEPTACLE / SIGNAL MULTI-SERVICE FLOORBOX.
REFER TO TELECOMMUNICATIONS NEW WORK PLANS
FOR SIGNAL REQUIREMENTS
OVERHEAD JUNCTION BOX
ELECTRICAL CONNECTION
TV
J
J
E
JUNCTION AND PULL BOXES
PULL BOX
SHADING INDICATES EMERGENCY POWER
JUNCTION BOX : CEILING OR FLOOR MOUNTED. SIZE
PER N.E.C. REQUIREMENTS.
JUNCTION BOX : WALL MOUNTED. SIZE PER N.E.C.
REQUIREMENTS.J
J
P
RACEWAYS
CABLE TRAY : TYPE AS NOTED
LADDER TRAY
WIRE IN CONDUIT, CONCEALED
WIRE IN CONDUIT, EXPOSED
CONTINUATION
HANDHOLE MANHOLEHH MH
A AMPERES
AC ALTERNATING CURRENT
ACS ACCESS CONTROL SYSTEM
AIC AMPERES INTERRUPTING CAPACITY
AV AUDIO/VIDEO
AWG AMERICAN WIRE GAUGE
BAS BUILDING AUTOMATION SYSTEM
C CONDUIT
CAT CATEGORY
CATV CABLE TELEVISION
CCTV CLOSED CIRCUIT TELEVISION
CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
CPP COPPER HORIZONTAL PATCH PANEL
CT CABLE TRAY
CU COPPER
CUH CABINET UNIT HEATER
CO COPIER
CP EMERGENCY CRITICAL POWER
DC DIRECT CURRENT
DEMO REMOVE AS INDICATED
DPST DUAL POLE, SINGLE THROW
DW DISHWASHER
EC EMPTY CONDUIT
EF EXHAUST FAN
EGC EQUIPMENT GROUNDING CONDUCTOR
EIA ELECTRONICS INDUSTRIES ASSOCIATIONS
EMT ELECTRICAL METALLIC TUBING
EOC EMERGENCY OPERATIONS CENTER
EP EMERGENCY POWER
EPO EMERGENCY POWER OFF
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FBO FURNISHED BY OTHERS
FO FIBER OPTIC
FPD FLAT PANEL DISPLAY
FPP FIBER OPTIC PATCH PANEL
FT FEET OR FOOT
GFI OR GFCI GROUND FAULT CIRCUIT INTERRUPTER
GC GENERAL CONTRACTOR
G OR GND GROUND
GFR GROUND FAULT RELAY
GFP GROUND FAULT PROTECTION
HZ HERTZ
IG ISOLATED GROUND
INV INVERTER
JBOX JUNCTION BOX
K KILO
KCMIL THOUSAND CIRCULAR MILS
KVA KILOVOLT AMPERES
KWH KILOWATT HOURS
LC LIGHTING CONTACTOR
LPI LIGHTNING PROTECTION INSTITUTE
MAX MAXIMUM
MCB MAIN CIRCUIT BREAKER
MDP MAIN DISTRIBUTION PANEL
MLO MAIN LUGS ONLY
MM MULTIMODE
MTD MOUNTED
MW MICROWAVE
N NEUTRAL CONDUCTOR
N.C. NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURES ASSOCIATION
NP NORMAL POWER
MA MANUFACTURER'S ASSOCIATION
NIC NOT IN CONTRACT
NL NIGHT LIGHT
N.O. NORMALLY OPEN
NTS NOT TO SCALE
OC ON CENTER
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI OWNER FURNISHED,OWNER INSTALLED
ONT OPTICAL NETWORK TERMINAL
P POLE
PR PAIR
PVC POLYVINYL CHLORIDE
R RELAY
REF REFRIGERATOR
RGS RIGID GALVANIZED STEEL CONDUIT
RN REPLACE WITH NEW
RMC RIGID METAL CONDUIT
SCCR SHORT CIRCUIT CURRENT RATING
SCH SCHEDULE
SE SECURITY ELECTRONICS
SM SINGLE MODE
SPD SURGE PROTECTION DEVICE
SPECS CONTRACT SPECIFICATIONS
SPST SINGLE POLE SINGLE THROW
STR STRAND
SWBD SWITCHBOARD
T TRANSFORMER
TC TELECOMMUNICATIONS POWER CRITICAL
TN TELECOMMUNICATIONS POWER NORMAL
TR TELECOMMUNICATIONS ROOM
TYP TYPICAL
UHF ULTRA-HIGH FREQUENCY
UL UNDERWRITERS' LABORATORIES
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UTP UNSHIELDED TWISTED PAIR
V VOLTS
VA VOLT AMPERES
VFD VARIABLE FREQUENCY DRIVE
VHF VERY HIGH FREQUENCY
VM VENDING MACHINE
W WIRE OR WATT
WP WEATHERPROOF
WR WEATHER-RESISTANT
XFMR TRANSFORMER
Z IMPEDANCE
ABBREVIATIONS
HALF-SHADING:
LIFE SAFETY POWER
NO SHADING:
NORMAL POWER
LIGHTING FIXTURES
1. "NL" INDICATES UNSWITCHED LUMINAIRE
2. NOTE THAT THE SIZE AND SHAPE OF FIXTURES AND ASSOCIATED HALF-
SHADING VARY BY FIXTURE TYPE
3. PROVIDE UNSWITCHED HOT CONDUCTOR TO FIXTURES WITH BATTERY
BACK UP, ONBOARD UL 924. REFER TO UL 924 DETAILS FOR ADDITIONAL
REQUIREMENTS.
HALF-SHADING:
CRITICAL POWER
A 1c
UPPER CASE LETTER - FIXTURE MARK
LOWER CASE LETTER - FIXTURE SWITCH LEG
NUMBER - FIXTURE CIRCUIT NUMBER
INDUSTRIAL PENDANT
LED LIGHTING, VARIOUS
LENGTHS
LINE VOLTAGE LIGHTING CONTROLS
AREA CONTROL SCHEME TAG
REFER TO LIGHTING CONTROL SCHEDULE
OCCUPANCY DETECTOR
ASTRONOMICAL TIMER SWITCH
CEILING DUAL TECHNOLOGY OCCUPANCY DETECTION
LIGHTING SENSOR
DIMMER
DT
OD
X
LC0
ROOM NAME
LC#
ROOM TAG
CONTROL SCHEME TAG
SUBSCRIPT LEGEND:
3 : 3-WAY SWITCH
4 : 4-WAY SWITCH
P : PILOT LIGHT SWITCH
C : MOMENTARY CONTACT SWITCH
a, b, ... : LOWERCASE SUBSCRIPT INDICATES SWITCH LEG
OD : WALL OCCUPANCY DETECTION
OR : OVER-RIDE SWITCH
LV : LOW VOLTAGE SWITCH
TOGGLE SWITCH
OD
1. WHERE TWO OR MORE SWITCHES ARE SHOWN ADJACENT TO EACH
OTHER, PROVIDE A COMMON GANG BOX WITH A SINGLE, SEAMLESS
FACEPLATE.
2. PROVIDE NEUTRAL AND UNSWITCHED HOT TO LINE VOLTAGE CONTROL
DEVICE WHEN REQUIRED.
3. SEE LIGHT FIXTURE CONTROL SCHEDULE FOR UL 924 AND UL 1008
REQUIREMENTS. SEE UL 924 AND UL 1008 DETAIL.
LS
D
ELECTRICAL DEMOLITION NOTES
1. REMOVE, CAP AND RELOCATE EQUIPMENT, OUTLETS, CONDUIT, WIRE, ETC., AS SHOWN AND SPECIFIED ON DRAWINGS, AND AS MAY BECOME NECESSARY BECAUSE OF EXISTING FIELD CONDITIONS. VISIBLY EXAMINE ALL EXISTING WALLS DESIGNATED FOR REMOVAL TO DETERMINE THE CONDUIT AND THE WIRING THAT WILL REQUIRE CAPPING AND REMOVAL, WHETHER OR NOT SUCH CONDITIONS ARE INDICATED ON THE DRAWINGS. FAILURE TO VISIT THE SITE AND TO TAKE ALL EXISTING CONDITIONS INTO ACCOUNT WILL NOT ALLOW FOR CHANGES TO THE
SCOPE OF WORK.
2. MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING FIXTURES, EQUIPMENT, OUTLETS, ETC., TO REMAIN IN USE WHETHER NOTED ON THE PLANS OR NOT. FIELD VERIFY EXISTING ITEMS TO REMAIN IN USE. RECONNECT RACEWAYS AND WIRING FOR EXISTING CIRCUITS WHICH MUST BE RE-ROUTED OR WHICH ARE PARTIALLY
ABANDONED TO POWER THE REMAINING OUTLETS ON THE CIRCUIT.
3. REMOVE ALL UNUSED WIRING AND CABLES BACK TO THEIR SOURCE. REMOVE ALL UNUSED CONDUIT THAT IS EXPOSED OR ABOVE ACCESSIBLE CEILINGS WHICH IS AFFECTED BY OR IS IN THE AREA OF THE DEMOLITION WORK.
4. THE INTENTION OF THE ELECTRICAL DEMOLITION DRAWINGS IS TO DISCONNECT AND REMOVE ALL ELECTRICAL WORK MADE VOID BY THE SCOPE OF THE CONSTRUCTION AND ALTERATION. FIELD VERIFY EXACT MATERIAL
QUANTITIES REQUIRED TO BE REMOVED.
5. DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL EQUIPMENT, DEVICES, ASSOCIATED RACEWAYS, SUPPORTING HARDWARE, AND WIRING, WHICH HAVE BEEN MADE OBSOLETE BY THE WORK OR IS SHOWN DASHED ON THE ELECTRICAL DEMOLITION DRAWINGS, UNLESS OTHERWISE NOTED. ALTHOUGH AN ATTEMPT HAS BEEN MADE TO INDICATE ALL OF THIS WORK, TOTAL ACCURACY IS NOT GUARANTEED. VISIBLY EXAMINE ALL AREAS AND WALLS AND
CEILINGS SCHEDULED FOR REMOVAL TO DETERMINE EXISTING ELECTRICAL ITEMS TO REMAIN.
6. WHERE THE REMOVAL OF ELECTRICAL EQUIPMENT, CONDUIT, BOXES, AND SUPPORTING HARDWARE REQUIRES WALL PATCHING AND REFINISHING, REFER TO ARCHITECTURAL FRONT-END SPECIFICATIONS FOR PATCH AND FINISH
WORK.
7. WHERE BURIED CONDUITS EXTENDING OUT OF A CONCRETE SLAB BECOME ABANDONED, CUT AND GRIND THE CONDUITS OFF FLUSH WITH TOP OF SLAB AND PLUG WITH NON-SHRINK WATERPROOF GROUT FILL.
8. TAKE ALL REMOVED MATERIALS FROM THE PROJECT SITE, EXCEPT FOR THOSE TO BE RELOCATED, STORED, OR
TURNED OVER TO THE OWNER.
9. ACCEPTANCE OF CONTRACT MEANS INSTALLER ACCEPTS EXISTING CONDITIONS.
10. COORDINATE ALL DEMOLITION WORK WITH ALL OTHER TRADES.
11. PROVIDE A BLANK COVER OVER THE OUTLET WHERE A FLUSH DEVICE IS BEING REMOVED FROM FLOORS AND WALLS THAT ARE TO REMAIN. MATCH THE COLOR AND MATERIAL TO THE EXISTING REMAINING COVERS IN THE ROOM OR
SPACE.
12. WHEN HAVING TO DISPOSE OF HAZARDOUS MATERIALS INCLUDING REMOVAL OF FLUORESCENT LIGHT FIXTURES WHERE BALLASTS CONTAIN PCBS AND LAMPS CONTAIN MERCURY, REFER TO ARCHITECTURAL FRONT-END SPECIFICATIONS FOR HAZARDOUS MATERIAL DISPOSAL GUIDELINES, AND COMPLY WITH ALL FEDERAL, STATE, AND
LOCAL LAWS.
13. MODIFY EXISTING PANEL DIRECTORIES (OR REPLACE) FOR PANELBOARDS WHICH HAVE HAD ALTERATIONS TO THE CIRCUITS ORIGINATING THEREIN. DESCRIBE THE LOAD AND LOCATION. TYPE, DO NOT HAND LETTER NEW
PANELBOARD DIRECTORIES.
ELECTRICAL GENERAL NOTES
1. MAKE ALL INSTALLATIONS IN ACCORDANCE WITH THE ARCHITECTURAL BARRIERS ACT (ABA).
2. MOUNTING HEIGHTS INDICATED WITHIN PLANS AND SCHEDULES ARE DIMENSIONED TO THE CENTER LINE OF
THE DEVICE, EQUIPMENT, LUMINAIRE, ETC. UNLESS OTHERWISE NOTED.
3. COORDINATE EXACT EQUIPMENT LOCATIONS WITH OTHER TRADES. EQUIPMENT LOCATIONS SHOWN ON
ELECTRICAL PLANS ARE DIAGRAMMATICAL ONLY AND MIGHT NOT BE EXACT.
4. CIRCUIT IDENTIFICATION NUMBERS BESIDE ELECTRICAL DEVICES AND CONNECTION POINTS ON PLANS CORRESPOND TO AN OVERCURRENT DEVICE IN THE DESIGNATED PANELBOARD. NOTE ALL CIRCUIT NUMBER CHANGES MADE IN THE FIELD AT EACH ELECTRICAL DEVICE AND CONNECTION POINT. ALSO CORRECT THE DIRECTORIES AND DEVICE MARKINGS AT PANELBOARDS, SWITCHBOARDS AND SWITCHGEAR TO ACCURATELY
REFLECT THE AS-BUILT CONDITIONS.
5. INSTALL EMERGENCY AND EXIT LUMINAIRE WIRING IN A SEPARATE RACEWAY FROM THAT OF ANY NORMAL
POWER DEVICE.
6. CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, ABOVE CEILINGS, AND IN FLOOR SLABS, ETC. UNLESS OTHERWISE INDICATED ON THE PLANS OR IN THE SPECIFICATIONS. CONDUIT ROUTED IN MECHANICAL ROOMS, ELECTRICAL ROOMS, AND STORAGE ROOMS WITHOUT CEILINGS MAY BE ROUTED EXPOSED.
7. COORDINATE VERTICAL CONDUIT ROUTING TO WALL MOUNTED DEVICES TO ENSURE DEVICES LOCATED
WITHIN AN 18-INCH HORIZONTAL DIMENSION WILL BE CENTER-ALIGNED VERTICALLY.
8. FIELD COORDINATE ALL ELECTRICAL AND TELECOMMUNICATIONS EQUIPMENT MOUNTING LOCATIONS TO AVOID ENCROACHMENT OF OPERATION AND ACCESS TO EQUIPMENT FROM OTHER TRADES. COORDINATE THE APPROPRIATE MOUNTING LOCATION WITH THE AFFECTED DISCIPLINES WHEN EQUIPMENT IS SPECIFIED
TO BE MOUNTED ONTO THE SURFACE OF ANOTHER DISCIPLINE'S EQUIPMENT.
9. REPAIR ALL OPENINGS MADE IN EXISTING WALLS, PARTITIONS, ETC TO ACCOMMODATE WORK OF THIS DISCIPLINE TO MATCH THE SURROUNDING CONDITIONS, USING WORKERS QUALIFIED IN THE APPROPRIATE
TRADE. APPROPRIATELY GROUT OR SEAL ALL CONDUITS THROUGH WALLS.
10. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS MUST HAVE BEEN TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF THROUGH-PENETRATION
FIRESTOPS.
11. PERFORM ALL WELDING ACCORDING TO AMERICAN WELDING SOCIETY STANDARDS. FURNISH CERTIFICATES QUALIFYING EACH WELDER TO THE ARCHITECT OR ENGINEER PRIOR TO START OF WORK. THE ARCHITECT OR ENGINEER RESERVES THE RIGHT TO REQUIRE QUALIFYING DEMONSTRATION, AT NO ADDITIONAL EXPENSE, OF ANY WELDERS ASSIGNED TO THE JOB.
12. REPLACE OR REINSTALL ALL PORTIONS OF THE BUILDING (CEILING TILES, WALLS, ETC) REMOVED TO ACCOMMODATE THE INSTALLATION OF ANY ELECTRICAL DEVICE, EQUIPMENT, ETC., USING WORKERS
QUALIFIED IN THE APPROPRIATE TRADE.
13. COORDINATE LUMINAIRE LOCATIONS SUCH THAT LUMINAIRES RUN PARALLEL TO THE FACE OF THE EQUIPMENT AND OVER AISLES BETWEEN EQUIPMENT IN ALL MECHANICAL AND ELECTRICAL EQUIPMENT AREAS. INSTALL AT PROPER LOCATIONS AND HEIGHTS TO PROPERLY ILLUMINATE ALL GAGES, PANELS, ELECTRICAL EQUIPMENT, CONTROLS, VALVES, ETC. CHAIN HANGING, STEM HANGING, CHANNEL HANGING, ETC. ARE ACCEPTABLE METHODS.
14. PROVIDE FIRE RATED AND WEATHER SEALANT AS REQUIRED TO SEAL PENETRATIONS.
15. UNLESS OTHERWISE NOTED, CONTRACTOR SHALL ROUTE NEW CONDUIT AS HIGH AS POSSIBLE IN CEILING
SPACES. COORDINATE ROUTING WITH EXISTING SYSTEMS AND OWNER.
16. PROVIDE CABLE SUPPORTS FOR VERTICAL CONDUIT RISER AS NECESSARY TO MEET MOUNTING
REQUIREMENTS. SEE ELECTRICAL DETAILS FOR FURTHER INFORMATION.
17. RACEWAY ROUNTING SHOWN ON FLOOR PLANS ARE TO SHOW THE INTENT. PULL BOXES, JUNCTION BOXES, FLOOR AND WALL PENETRATIONS SHALL BE PROVIDED FOR A COMPLETE INSTALLATION.
ELECTRICAL PHASING NOTES
1. PRIOR TO STARTING CONSTRUCTION OF NEW TELECOM ROOM (TR) ROOMS AND DATA CENTER WORK, CONTRACTOR WILL PARTICIPATE IN PHASING MEETINGS WITH OWNER AND CONTRACTORS OF OTHER DISCIPLINES TO DISCUSS MEANS AND METHODS FOR PHASING THE INSTALLATION OF NEW IT EQUIPMENT AND THE REMOVAL OF OLD EQUIPMENT AFTER NEW EQUIPMENT IS RUNNING, VERIFIED, AND CIRCUITS CUT OVER. IT IS IMPORTANT THAT NEW IT EQUIPMENT BE INSTALLED AND TESTED PRIOR TO REMOVING OLD EQUIPMENT.
2. FOR NEW TELECOM ROOMS (TR’S) AND DATA CENTER, NEW DATA RACKS WILL BE CONSTRUCTED, POWERED, AND DATA CIRCUITS CUT OVER PRIOR TO REMOVAL OF EXISTING IT RACKS. NOTE THAT EXISTING AND NEW
RACKS WILL HAVE TO BOTH BE POWERED AT THE SAME TIME FOR CONSTRUCTION PHASING.
4. POWER OUTAGES WILL BE REQUESTED AND DISCUSSED A MINIMUM OF 4 WEEKS PRIOR TO SCHEDULING THE OUTAGE. EACH OUTAGE AND METHOD OF PROCEDURE WILL BE DISCUSSED IN DETAIL WITH THE OWNER AND ALL INVOLVED CONTRACTORS PRIOR TO OUTAGE. CONTRACTOR SHALL VERIFY WHAT EQUIPMENT OR CIRCUITS WILL BE IMPACTED IN ORDER THAT ALL PERTINENT STAFF CAN BE NOTIFIED IN TIMELY MANNER. VERIFY
OWNER’S OUTAGE TIMEFRAME CONSTRAINTS WHEN SCHEDULING OUTAGES.
5. MOST KEY WORK IN PATIENT CARE AREAS REQUIRING OUTAGES, CUT-OVERS, ETC. WILL BE PERFORMED DURING PREMIUM TIME, (NIGHTS OR WEEKENDS), WITHIN DESIGNATED ALLOWABLE TIME-FRAME DICTATED BY
THE OWNER.
6. FOR EXISTING ACTIVE CIRCUITS THAT NEED TO BE CUT-OVER TO NEW PANEL, ENSURE THAT CIRCUITS ARE CUT- OVER PRIOR TO REMOVING OLD PANEL. EC SHALL VERIFY ALL EXISTING ACTIVE CIRCUITS THAT REQUIRE NEW
FEED.
7. COORDINATE ALL ELECTRICAL WORK AFFECTING IT RACKS IN TR ROOMS AND DATA CENTER CLOSELY WITH
OWNER, CONSTRUCTION MANAGER, AND CONTRACTORS OF OTHER DISCIPLINES.
St. Louis
6 South Old Orchard t: +1 800.404.7677 St. Louis, MO 63119 e: hello@introba.com www.introba.com
8718 Botts Lane Phone: (210) 816-4784
San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project TitlePhaseDrawing Title
Approved:
ARCHITECT OF RECORDCONSULTANT
Revisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
FULLY SPRINKLERED
100% BID
DOCUMENTS
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
01/16/2026
642-22-700EHRM Infrastructure Upgrades -
CMCVAMC
3900 Woodland Avenue Philadelphia, PA 19104
ELECTRICAL SYMBOLS & ABBREVIATIONS
BKM MS
E-000
1, 2, 3, 21
1-16-26
BUILDING 1 - EXISTING A001
NOTE: PROPOSED ELECTRICAL SPACE WILL HOUSE PLAN EAST SIDE OF
BUILDING 1 TR DISTRIBUTION. EXISTING 2-ATS-12 AND ELECTRICAL
EQUIPMENT SHALL BE REMOVED. EXISTING (3) CONDUIT FEEDERS FED
IN CRAWL SPACE, BELOW RAISED FLOOR, CONNECTED TO EXISTING ATS
AND CONDUIT FEEDER CONNECTED TO PANEL PP1 SHALL REMAIN AND
BE UTILIZED IN NEW DISTRIBUTION. EXISTING UPS WITH NO BATTERIES
AND UPS PANEL SHALL BE REMOVED AFTER PHASING IS COMPLETE.
NOTE: LIEBERT CRAC UNIT AND IT EQUIPMENT IN A001 PROPOSED
ELECTRICAL ROOM SPACE WILL EVENTUALLY BE REMOVED.
NOTE: CONDUITS FROM BASEMENT LEVEL FEED UP OUTSIDE OF
BUILDING 1 TO ROOM A228 DISTRIBUTION BOARD MDP.
EXISTING ELECTRICAL ROOM SPACE IN A001 EXISTING SOUTH AREA OF A001 SPACE - LEFT
EXISTING PLAN NORTH AREA OF A001 SPACE - LOOKING TOWARDS TR A001D EXISTING CONDUITS FEEDING 2ND FLOOR MDP ELECTRICAL CLOSET TO BE USED FOR A001E TR RISER
NOTE: DOUBLE-DOOR ELECTRICAL CLOSET A001 ON BACK SIDE OF STAIR
#1. THESE ELECTRICAL CLOSETS STACK VERTICALLY FROM BSMT TO 9TH
FLOOR. OLD TELECOM PULL BOX AND EXISTING CONDUIT RISERS ON
RIGHT SIDE OF CLOSET SHALL BE REMOVED AND REPLACED WITH NEW
CONDUIT RISERS FOR TR DISTRIBUTION.
RISER LOCATION
PICTURE 1 PICTURE 2
PICTURE 6
PICTURE 5
EXISTING SOUTH AREA OF A001 SPACE - RIGHT
PICTURE 3
NOTE: EXISTING UPS HAS NO BATTERIES. POWER IS FEEDING THROUGH
VIA BYPASS FROM PANEL PP2 TO UPS PANELS.
T-MOBILE ANTENNA SYSTEM
PICTURE 4
NOTE: T-MOBILE ANTENNA SYSTEM SHALL REMAIN
IN PLACE. SYSTEM IS FED FROM PANEL PP2-17.
SEE PHASING NOTE AND LIMIT OUTAGE TIME
WHEN CUTTING T-MOBILE CIRCUIT OVER.
COORDINATE OUTAGE WITH FACILITIES.
PICTURE 7
St. Louis
6 South Old Orchard t: +1 800.404.7677 St. Louis, MO 63119 e: hello@introba.com www.introba.com
8718 Botts Lane Phone: (210) 816-4784
San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project TitlePhaseDrawing Title
Approved:
ARCHITECT OF RECORDCONSULTANT
Revisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
FULLY SPRINKLERED
100% BID
DOCUMENTS
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
01/16/2026
642-22-700EHRM Infrastructure Upgrades -
CMCVAMC
3900 Woodland Avenue Philadelphia, PA 19104
BLDG 1 PICTURE REFERENCES
BKM MS
1-E-010
BUILDING 1 - EXISTING B022A
NOTE: PROPOSED ELECTRICAL SPACE WILL HOUSE PLAN WEST SIDE OF
BUILDING 1 TR DISTRIBUTION. EXISTING ATS-6 AND ELECTRICAL
EQUIPMENT SHALL BE REMOVED, BUT CONDUIT FEEDERS TO ATS SHALL
REMAIN.
NOTE: EXISTING UPS SHALL BE REMOVED.
NOTE: EXISTING NORMAL POWER PANEL AND BREAKER FED
FROM BUS DUCT SHALL BE REPLACED. CONDUIT FEEDER TO
ATS NORMAL POWER INPUT SHALL BE REUSED.
NOTE: EXISTING NORMAL POWER BUS DUCT AND FEEDERS SHALL
REMAIN. PANEL HSB AND PANEL UPS-B SHALL BE REMOVED.
PROPOSED ELECTRICAL ROOM SPACE IN B022 (PLAN EAST SIDE - LEFT) PROPOSED ELECTRICAL ROOM SPACE IN BO22 (PLAN EAST SIDE - RIGHT) NORMAL POWER BREAKER FED FROM BUS DUCT TO ATS INPUT
EXISTING BUS DUCT AND PANELS (PLAN EAST SIDE - RIGHT)
NOTE: CLOSET RISES VERTICALLY IN PLACE. NEW CONDUIT SHALL
BE INSTALLED ON RIGHT SIDE OF EXISTING CLOSET.
CONDUIT RISER LOCATION FOR B022B TR RISER
RISER LOCATION
NOTE: PROVIDE NEW BUS DUCT FUSE SWITCHES AS
NECESSARY TO FEED NORMAL POWER TR-NP-BB AND
NORMAL POWER INPUT FOR TR-ATS-BB. SEE ONE-LINE.
BUS DUCT FUSE SWITCH IN CLOSET
PICTURE 8 PICTURE 9 PICTURE 10
PICTURE 11
PICTURE 12 PICTURE 13
St. Louis
6 South Old Orchard t: +1 800.404.7677 St. Louis, MO 63119 e: hello@introba.com www.introba.com
8718 Botts Lane Phone: (210) 816-4784
San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project TitlePhaseDrawing Title
Approved:
ARCHITECT OF RECORDCONSULTANT
Revisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
FULLY SPRINKLERED
100% BID
DOCUMENTS
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
01/16/2026
642-22-700EHRM Infrastructure Upgrades -
CMCVAMC
3900 Woodland Avenue Philadelphia, PA 19104
BLDG 1 PICTURE REFERENCES
1-E-011
TO TUNNEL & CHILLER
BUILDING (BLDG. #31)
SUB-BASEMENT
MECHANICAL ROOM
SB1
St. Louis
6 South Old Orchard t: +1 800.404.7677 St. Louis, MO 63119 e: hello@introba.com www.introba.com
8718 Botts Lane Phone: (210) 816-4784
San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project TitlePhaseDrawing Title
Approved:
ARCHITECT OF RECORDCONSULTANT
Revisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
FULLY SPRINKLERED
100% BID
DOCUMENTS
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
01/16/2026
642-22-700EHRM Infrastructure Upgrades -
CMCVAMC
3900 Woodland Avenue Philadelphia, PA 19104
KEYPLAN
BLDG
BLDG
BLDG
BLDG 1 OVERALL SUB-BASEMENT PLAN
BKM MS
1-E-100
1/8" = 1'-0"
BLDG 1 OVERALL SUB-BASEMENT PLAN
PLAN
NORTH
TRUE
NORTH
SHEET NOTES 1-E-100
GEN NOTES:
1 PLAN FOR REFERENCE ONLY, NO CURRENT ELECTRICAL SCOPE
IN THIS AREA.
STOR
A001B
TR
A001D
TR
B022B
ELECTRICAL
ROOM
B022A
ELECTRICAL
ROOM
A001E
FINANCE / FISCAL
MY HEALTHE VET
BIOMED
FACILITIES MANAGEMENT SHOPS
LIBRARY
MORGUE
Radiator
Radiator
Radiator RadiatorRadiator
STAIR #2
STAIR #3
STAIR #4
LOADING DOCK
STORAGE B002A
STORAGE
B035A
SYSTEMS
ENGINEER B033
ELECTRIC
SHOP
B026
M/R CHIEF
B032
ELECTRIC
SHOP A
B027 PLUMBING
SHOP
STORAGE
B031A
LOCK
SHOP
B038
OXYGEN
STOR.
B039
OXYGEN
STOR.
B040
PLUMBING
SHOP
B031
SOILED
LINEN
A027
A028
PASSENGER
ELEVATORS
SERVICE
ELEVATORS
A001A
MECH.
ROOM
A001C
OLD
COMPUTER
ROOM
A001
FIRE
ALARM
ROOM
A004A
SOILED
LINEN A006
ELECTRIC
ROOM
A009
PHONE
EQUIP.
A008D
ENGINEERING
MECHANICAL
ROOM
A005
MEN'S TOILET
ROOM
GC113
ELEVATOR
MACHINE
ROOM
GC112
O.R.
PREP RM.
A028C
UNIFORM
STORAGE
A028D
H.A.C.
GC110
WOMEN'S
TOILET ROOM
GC111
STORAGE
GC115
PC
VIEWING
GC129
CLERK
GC123
BOOK
PROCESSING &
STORAGE
GC122
CLERK
AREA
GC121
LIBRARIAN'S
OFFICE
GC125
ELECTRICAL
ROOM
GC128
STAIRS
GCS1
TO BUILDING 2
A/C MACH.
ROOM
B009
POLICE
TRAINING
ROOM
B007
ED
ELEVATOR
CANTEEN
OFFICE
B007A
JAN.
CLO.
B006
SOILED
LINEN
B005
CORRIDOR
CA-10
LOCKER
ROOM
B004
STORAGE
B003
STORAGE
B003A
CORRIDOR
CA-11
TO
RESEARCH
WING
STORAGE
B002
POLICE
SECURITY
STORAGE
A015A
POLICE
SECURITY
STORAGE
A015B
BIOMED
A015
MECHANICAL
A014
MECHANICAL
A014
FMS TLT &
LOCKER RM
A008E
IT/ MECHANICAL
A008C
IT/ MECHANICAL
A008B
MECHANICAL
A008A
PATIENT
CLOTHING
A007
CORRIDOR
CA-6
MECH
A004
ELEVATOR
LIBRARY
GC120 MY HEALTHE
VET
GC126
CORRIDOR
CA-5A
OFFICE
GC103
OFFICE
GC102
HR
OFFICE
GC101
HR
OFFICE
GC100
CORRIDOR
CA-3A
CORRIDOR
CA-4
SIGN ROOM
A019
CORRIDOR
CA-3
MEDICAL WASTE
ROOM
A018
EMS DIRTY
STORAGE
A017
EMS CLEAN
STORAGE
A017A
SERVICE
ELEVATOR
LOBBY
CA-2
CANTEEN STORAGE
A016B
ELEVATOR LOBBY
CA-1
IT CLO
A013C
IT CLO
A013B
CORRIDOR
CA-1A
POLICE
STOR
A016A
ELEC
CLO
A012
FMS CLO
A013A
STAIR #1
ELEC
CLO
A011
FAMILY
VIEWING
ROOM
B019
RADIATION
SAFETY
B020
SPS
STORAGE
B020
CORRIDOR
CA-12
CORRIDOR
CA-9
TO BUILDING 2
CARPENTER
SHOP
FOREMAN
B034
CORRIDOR
CA-13
PAINT
SHOP
B035
CORRIDOR
CA-15
TO BUILDING 2 CORRIDOR
CA-8
MASONRY
SHOP
B036
PAINT
SHOP
B037
CORRIDOR
CA-7
A016E
CORRIDOR
CA-14
EMS
STORAGE
A021
EMS
STORAGE
A020
TRASH ROOM
A022
MORGUE
ENTRANCE
A023
WASH RM
A023B
AUTOPSY AREA
A023C
MORGUE
BOX
A023D
EMS
OFFICE
A025
VAULT
A026A
VAULT
A026B
POLICE
LOCKER RM
A026
EMS LINEN ROOM
LINEN ROOM
A028B
ELEVATOR
CORRIDOR
CA-5
FINANCE
GC104
CANTEEN
A016H
CANTEEN
A016G
CANTEEN
A016E
ELEC CLO
A016J
CANTEEN
A016C
CANTEEN
A016D
MACH. RM.
A016K
EMS OFFICE
A024
A/C UNIT
A028A
OI&T
B022
TRANSFORMER
ROOM
A010
CARPENTER
SHOP
B035
MACHINE
SHOP
B030
A/C SHOP BO28
MECHANICAL
ROOM
BO29
E E
EEEE
EE
B022A
1-E-200
1-E-205
1-E-206
1-E-201
1-E-207
TR-EDP-BA
TR-NDP-BA
TR-EDP-BB
TR-NDP-BB
CPLIT-1-B022B
NPLIT-1-B022B
CPLIT-1-A001DNPLIT-1-A001D
1-E-105
1-E-105
TO A001E GROUND
TO B022A GROUND
TO A001E
GROUND
A010 GROUND BAR
A009 GROUND BAR
NORMAL POWER TR RISER
EMERGENCY POWER TR RISER
FEEDERS FROM TR-EDP-BB
FEEDERS FROM TR-NDP-BA
EXISTING ELECTRICAL PANELS ETR
NORMAL POWER TR RISER
EMERGENCY POWER TR RISER
FEEDERS FROM TR-EDP-BB
FEEDERS FROM TR-NDP-BB
St. Louis
6 South Old Orchard t: +1 800.404.7677 St. Louis, MO 63119 e: hello@introba.com www.introba.com
8718 Botts Lane Phone: (210) 816-4784
San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project TitlePhaseDrawing Title
Approved:
ARCHITECT OF RECORDCONSULTANT
Revisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
FULLY SPRINKLERED
100% BID
DOCUMENTS
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
01/16/2026
642-22-700EHRM Infrastructure Upgrades -
CMCVAMC
3900 Woodland Avenue Philadelphia, PA 19104
KEYPLAN
BLDG
BLDG
BLDG
BLDG 1 OVERALL BASEMENT PLAN
BKM MS
1-E-105
1/16" = 1'-0"
BLDG 1 OVERALL BASEMENT PLAN
SHEET NOTES 1-E-105
KEYED NOTES:
1 VERTICAL CONDUIT RISER LOCATION. (8) CONDUITS FOR
NORMAL POWER AND (8) CONDUITS FOR EMERGENCY POWER
ARE FED FROM ELECTRIC ROOM A001E. ROUTING INFORMATION
IS DIAGRAMATIC AND IS NOT INTEDED TO SHOW EXACT
CONDUIT ROUTES. SEE ENLARGED PLANS FOR FURTHER
DETAIL.
2 VERTICAL CONDUIT RISER LOCATION. (5) CONDUITS FOR
NORMAL POWER AND (5) CONDUITS FOR EMERGENCY POWER
ARE FED FROM ELECTRIC ROOM B022A. ROUTING INFORMATION
IS DIAGRAMATIC AND IS NOT INTEDED TO SHOW EXACT
CONDUIT ROUTES. SEE ENLARGED PLANS FOR FURTHER
DETAIL.
3 PROVIDE CONDUIT FEEDER FROM 2ND FLOOR A228 MDP TO
A001E TRANSFORMER. SEE ENLARGED PLAN.
5 DIVISION 27 WORK, SEE TECHNOLOGY DRAWINGS FOR
FURTHER DETAILS. PROVIDE GREEN INSULATED STRANDED
COPPER GROUND CONDUCTOR FROM BLDG 2 EXISTING
GROUND BARS IN A009 & A010 TO BOTH BASEMENT FLOOR
TELECOMMUNICATION ROOMS: A001D AND B022B (TR) SBB
GROUND BARS AS INDICATED FOR TELECOMMUNICATIONS
GROUND. ROUTE IN CONDUIT THROUGH CEILING SPACE;
COORDINATE WITH EXISTING SYSTEMS IN THE CEILING.
PROVIDE SUPPORTS AT 5-FOOT INTERVALS. SEE TECHNOLOGY
RISER DRAWING FOR GROUND CABLE CONNECTIONS BETWEEN
TR ROOMS. PROVIDE CORE-DRILLS AS NECESSARY. USE
COMPRESSION LUGS AND TERMINATE TO EACH GROUND BAR
WITH 2-HOLE LUGS. SEE GROUNDING DETAIL FOR FURTHER
DETAILS.
1/2" = 1'-0"
TR A001E RISER ENLARGED PLAN
1/2" = 1'-0"
TR B022B RISER ENLARGED PLAN
PLAN
NORTH
TRUE
NORTH
Family Toilet Rm
B101
Women's Toilet Rm
B102
Lactation Room B103
EXAM
#1
B137
EXAM #2
B138
STORAGE
B139
STAIR
NO 4
CORRIDOR
C1-15C
LAB
B136
TOUCH
DOWN
B135
CORRIDOR
C1-15
ISO
EXAM #3
B140
ISO
EXAM #4
B141
ISO
EXAM #5
B142
EXAM #7
B144
EXAM #6
B143
EXAM #9
B147
SOCIAL/
EXAM #8
B146
ELEC
CLO
B145
SOILED
HOLDING
B134
PHARM
OFFICE
B133
MEDS
B132
CORRIDOR
C1-15A EXAM #10
B148
EXAM #11
B149
EXAM #12
B150
MECHANICAL
ROOM
B151
TOUCH
DOWN
B131
TRIAGE
B130 CORRIDOR
C1-14
MOD E
RECEPTION
B134
MOD E
WAITING
B132
HAC
B124
CORRIDOR
C1-13
MEN
TLT
HC
B122
STAIR
NO 3
ELEC
B122FEC
GALLERY
B121
ACCESS
FROM B2ACCESS
FROM B2
CORRIDOR
C1-12
CORRIDOR
TO ED
SUICIDE
PREVENTION
B118
HAS
B117
ED AO
B116
NUTRITION
FUTURE ED
BREAK
B115
ELEVATOR
ED
EXAM
ROOM
B112
UNISEX
TOILET
B111
ED
EXAM
ROOM
B110
ED
EXAM
ROOM
B109
ED
EXAM
ROOM
B108
ED
EXAM
ROOM
B107
ED
EXAM
ROOM
B106
ED
EXAM
ROOM
B105
ED
EXAM
ROOM
B104
CORRIDOR
C1-11
CORRIDOR
C1-10
FOOD
COURT
A142
FOOD LINE
A142B
FOOD LINE
A142C
FOOD LINE
A142A
CANTEEN
DINING
AREA
A140
DISHWASHER
A144A
COOLERS
A143
KITCHEN
A144
CAGE
STORAGE
A146
CAGE
STORAGE
A145A
CANTEEN
DINING
AREA
A145
A148 A149 A150
ELE CLO
A151
SERVICE
ELEVATOR
C1-2
MEN
TOILET HC
A153
PRIVACY
OFFICE
A154
CONGRESSIONAL
LIASON
A154B
STAIR
NO 5
WOMEN
TOILET HC
A155
VISN 4
CONFERENCE
ROOM
A157
VISN
OFFICE
A157A
CORRIDOR
C1-4
ELEC
CLO
A158
CONFERENCE
ROOM
A160
OFFICE
A161
OFFICE
A162
OFFICE
A162A
OFFICE
A163
PATIENT
ADVOCATE
FUTURE
PCS
A159
DECEDENT AFFAIRS
AFFAIRS
A164
OFFICE
1C101
OFFICE
1C111
WORK
ROOM
1C110
OFFICE
1C109
OFFICE
1C108
OFFICE
1C107
OFFICE
1C106
OFFICE
1C105
OFFICE
1C104
OFFICE
1C103
PCS
1C100
WAITING
1C102
FUTURE
QUALITY
MANAGEMENT
1C122
1C127
OFFICE
1C126
PRIVACY
OFFICE
1C125
OFFICE
(FRONT OFFICE)
1C124
OCC
OFFICE
1C123
CONFERENCE
ROOM
1C138
CHIEF OF
STAFF
1C137
1C136
1C135
1C134
1C133
STAIR
NO 1
1C-S1
1C132
1C129A1C131
CHIEF OF
STAFF OFFICE
1C129
CORRIDOR
C1-5
STORAGE
1C121
ELEVATOR
P.
ELEC
CLO
1C118
TELE
CLO
1C120
A174F
A174E
A174DA174CA174B
ASSISTANT
DIRECTOR
A175
BOARD ROOM
VESTIBULE
A177A
DIRECTOR'S
SUITE
A174
WOMEN
STAFF
ONLY HC
1C117
MEN STAFF
ONLY HC
1C115
HAC
1C114
CLOSET
1C113
COMPLIANCE
OFFICER
A156
A174G
A174I
A174H
CORRIDOR
C1-3A
CORRIDOR
C1-3
BOARD ROOM
A177
CORRIDOR
C1-1A
VA POLICE
OPERATIONS
A101
STAFF
A101A
TELEPHONE
OPERATOR
A102
CORRIDOR
C1-6
TLT
A103
HAC
A104
COPY/ EQUIPMENT
ROOM
A105A
OFFICE
A105B
OFFICE
A105C
OFFICE
A105F
OFFICE
A105G
OFFICE
A105H
STUDIO
A105E
MEDICAL
MEDIA
PERSONNEL
A105D
CORRIDOR
C1-7
MEDICAL
MEDIA
A105
HOLDING
ROOM
A106A
HOLDING
ROOM
A106B
VA POLICE
HOLDING
ROOM
A106
STAFF
OFFICE
A107C
UNISEX
TLT RM
A107B
CONFERENCE
ROOM
A107D
STAFF
AREA
A107E
PRINTER
AREA
A107A
OFFICE
A107I
STORAGE
A107H
TELE
CLOSET
A107F
OFFICE
A107G
QM
OFFICE
A108B
QM
OFFICE
A108C
QM/ FUTURE
PATIENT ADVOCATE
A108
QM
OFFICE
A108A
QM
A107
QM
A108D
QM/ FUTURE
DECEEDENT
AFFAIRS
A109
ELEC
CLO
A119
CARD
SAFE
A111A
PIV
A111
VA POLICE
SERVICE
A112
CORRIDOR
C1-8
STAIR
NO 2
VA CRIMINAL
INVESTIGATOR
A113
ASSISTANT
CHIEF OF POLICE
A114
CHIEF
OF
POLICE
A115
VA POLICE
ADMINISTRATION
A116
STAIR
NO 1
ELEC
CLO
A135
ELEC
CLO
A136
TELE
CLO
A136A
FEC
STORAGE
A39B
ELEVATOR LOBBY
C1-1
MECHANICAL
ROOM
1D102
OFFICE
A139C
RETAIL STORE
A139A
CORRIDOR
C1-9
CORRIDOR
C1-15B
B113
B113A
LAUNDRY
CHUTE
B113D
TR
A154A
TR
B112A
CLOSET
A154B
F E
C
GATE
GATE
CONSTRUCTIONCONSTRUCTION
TO SOUTH BUILDING
(BUILDING 2)
TO SOUTH BUILDING
E E
E E
E E E E
EEEEEE
E E
1-E-210
1-E-211
CPLIT-1-A154A
NPLIT-1-A154A
CPLIT-1-B112A
NPLIT-1-B112A
St. Louis
6 South Old Orchard t: +1 800.404.7677 St. Louis, MO 63119 e: hello@introba.com www.introba.com
8718 Botts Lane Phone: (210) 816-4784
San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project TitlePhaseDrawing Title
Approved:
ARCHITECT OF RECORDCONSULTANT
Revisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
FULLY SPRINKLERED
100% BID
DOCUMENTS
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
01/16/2026
642-22-700EHRM Infrastructure Upgrades -
CMCVAMC
3900 Woodland Avenue Philadelphia, PA 19104
KEYPLAN
BLDG
BLDG
BLDG
BLDG 1 OVERALL FIRST FLOOR PLAN
BKM MS
1-E-110
1/16" = 1'-0"
BLDG 1 OVERALL FIRST FLOOR PLAN
SHEET NOTES 1-E-110
KEYED NOTES:
1 CONDUIT RISER FROM BASEMENT.
PLAN
NORTH
TRUE
NORTH
TR
A207
TR
B228A
WALL PASS THRU N.I.C.
TO BUILDING 2
ACCESS PANEL
21" HIGH
TO
RESEARCH
WING
INPATIENT PHARMACY
REHABILITATION
IMPACT, BH, PCS & HAS
REHABILITATION
Printer
PASS-THRU REFRIG.
PASS-THRU FREEZER
LF
HOOD
N.I.C.
LF
HOOD
N.I.C.
LF
HOOD
N.I.C.
RESEARCH
B228D
RESEARCH
B228E RESEARCH
B228F
STAIR #4
CORRIDOR
C2-15
B228GRESEARCH
B228C
RESEARCH
B228B
CL
B228H
CL.
B228J
OFFICE
POOL
B228
INTERVIEW
B227
INTERVIEW
B226
OFFICE
B225A
OFFICE
B225B
WAITING
B225
CORRIDOR
C2-14
CORRIDOR
C2-13
MEN'S
TOILET
B224
STAIR #3
ELEC
B223FEC
B222
BOARD RM/
CONFERENCE
B221
ELEC
CLO
B221A
CORRIDOR
C2-122
CONFERENCE
VESTIBULE
B220H.A.C.
B219
STORAGE
B220A
BEHAVIORAL
HEALTH
OFFICE
B218
BEHAVIORAL
HEALTH
OFFICE
B217
BEHAVIORAL
HEALTH
OFFICE
B216
BEHAVIORAL
HEALTH
OFFICE
B215
BEHAVIORAL
HEALTH
OFFICE
B214
BEHAVIORAL
HEALTH
OFFICE
B213
BEHAVIORAL
HEALTH
OFFICE
B212
ED
ELEVATOR
BEHAVIORAL
HEALTH
OFFICE
B210
BEHAVIORAL
HEALTH
OFFICE
B209
BEHAVIORAL
HEALTH
OFFICE
B208
ELEC
CLO
B207
CESATE
B206
BEHAVIORAL
HEALTH
B205B
BEHAVIORAL
HEALTH
B203
BEHAVIORAL
HEALTH
B202C
BEHAVIORAL
HEALTH
B202B
BEHAVIORAL
HEALTH
B202A
BEHAVIORAL
HEALTH
B201
EEO
B205A
EEO
B204
CORRIDOR
C2-10A
CORRIDOR
C2-10
BULK
STORAGE
A237
CORRIDOR
C2-9
STAGING
AREA
RECEIVING
AREA
FILL
AREA
A236I
SUPERVISOR
INPATIENT
PHARMACY
A236H
ANTE
ROOM
A236F
IV
SOLUTION
ROOM
A236G
RESEARCH
A236E
COMPOUNDING
ROOM
A236D
CONTROLLED
SUBSTANCE
VAULT
A236C
PROCUREMENT
TECH
A236B
WORK
ROOM
A236J
INPATIENT
PHARMACY
A236
DUMB
WAITER
HAC
A236A
STAIR
NO 1
FEC
A235E ELEC
CLO
A235D
ELEC
A235C
CORRIDOR
C2-1A
ELEVATOR
LOBBY
C2-1
ELEC
CLO
A253F
REHAB
WAITING
A202
OFFICE
A203
OFFICE
A204
OFFICE
A231
OFFICE
A230
BEHAVIORAL
HEALTH
TOUCHDOWN
A229
ELEC
A228 CL
A229A
IMPACT
EXAM
ROOM
A227
STAIR #2
IMPACT
PHYSICIAN
A226B
IMPACT
NURSING
A226A
IMPACT
NURSING
A225
IMPACT
TOUCH
DOWN
A224
ASST. NURSE
MANAGERS
A223
NURSE
RESEARCHERS
A222
NURSING
A221
NURSING
A220
SAFE PATIENT
HANDLING
A219
HAS
SUPERVISORS
A218
IMPACT
TOUCHDOWN
A217
CORRIDOR
C2-8
IMPACT
EXAM ROOM
A216
TOILET
A215
TOILET
A214
VACANT
A213
VACANT
A212
ISO
A211
BEHAVIORAL HEALTH
TOUCHDOWN
A210
HAS
A209
GI
STOR
A208
IMPACT
RECEPTION
A206
CORRIDOR
C2-7
CORRIDOR
C2-6A
IMPACT
WAITING
A205
CORRIDOR
C2-6
RECEPTION
A201
OFFICE
A200
REHAB
OFFICE
A262
6 PERSON
TOUCHDOWN
A260
ELEC
A261
LOW
VISION
A259A
LOW
VISION
A259
LOW
VISION
A258
CHIEF OF
REHAB-
ILITATION
A257
SCI
CLINIC
A256 REHAB
A255
REHAB
A255A
RESIDENT'S
OFFICE
A254
OFFICE
A253
OFFICE
A252
OFFICE
A251
CORRIDOR
C2-5
WOMEN
STAFF
TLT HC
A250
MEN
STAFF
TLT HC
A249
CORRIDOR
C2-3A
HAC
A248
EXAM
A247
EXAM
A246
EXAM
A245
EXAM
A244
OT
A243A
OCCUPATIONAL
THERAPY
A243
ELEC
CLO
A242
ADL
BATH
A243B
ADL
KITCHEN
A243C CORRIDOR
C2-4
STORAGE
A241
STAIR
NO 5
EXAM
A240D
EVALUATION
ROOM
A240C
STAFF
AREA
A240B
STORAGE
A240A
CORRIDOR
C2-3
PHYSICAL
THERAPY
A239
MEN
TLT HC
A237
WOMEN
TLT HC
A238
CLEAN
LINEN
A239A
SERVICE
ELEVATOR
LOBBY
C2-2
CLO
A239B
ELEC CLO
A239C
SERVICE
ELEVATORS
SIGNAL
A235B
DATA
A235A
PASSENGER
ELEVATORS
CHANGING
ROOM
A239E
CHANGING
ROOM
A239F
STORAGE
A239D
UTILITY
SUPPLY
A239G
PROSTHETICS
REPRESENTATIVES
B238G
PROSTHETICS
RECEPTION
B238
PROSTHETICS
REPRESENTATIVES
B238F
ORTHOTIST
EXAM
B238E
ORTHOTIST
SHOP
B238D
PROSTHETICS
CHIEF
B238C
PROSTHETICS
REPRESENTATIVES
B238B
PROSTHETICS
REPRESENTATIVES
B238A
FILES
B233A
RECEPTION/
WORK
B233
WOMEN'S
TOILET
B232
EXAM/
INTERVIEW
B231
SPECIMEN
B230
EXAM/
INTERVIEW
B229
CORRIDOR
C2-11
E E
E E
E E
EE
EE
EEEEEE
ROOF
ROOF
1-E-220
1-E-222
1-E-221
CPLIT-1-B228BNPLIT-1-B228B
CPLIT-1-A207
NPLIT-1-A207
St. Louis
6 South Old Orchard t: +1 800.404.7677 St. Louis, MO 63119 e: hello@introba.com www.introba.com
8718 Botts Lane Phone: (210) 816-4784
San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project TitlePhaseDrawing Title
Approved:
ARCHITECT OF RECORDCONSULTANT
Revisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
FULLY SPRINKLERED
100% BID
DOCUMENTS
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
01/16/2026
642-22-700EHRM Infrastructure Upgrades -
CMCVAMC
3900 Woodland Avenue Philadelphia, PA 19104
KEYPLAN
BLDG
BLDG
BLDG
BLDG 1 OVERALL SECOND FLOOR PLAN
BKM MS
1-E-120
1/16" = 1'-0"
BLDG 1 OVERALL SECOND FLOOR PLAN
SHEET NOTES 1-E-120 KEY
KEYED NOTES:
1 CONDUIT RISER FROM A228 MDP TO BASEMENT A001E
TRANSFORMER. SEE ENLARGED PLAN. ON A SEPARATE
PROJECT THE VA IS ADDING A NORMAL POWER MOTOR
CONTROL CENTER (MCC) IN THE BASEMENT. EC MAY ELECT TO
USE THIS NEW MCC FOR NORMAL POWER SOURCE INSTEAD OF
2ND FLOOR A228 MDP.
2 CONDUIT RISER FROM BASEMENT.
PLAN
NORTH
TRUE
HAS
B317
TR
B317A
TR
A361
TO BUILDING 2 CHAPLAIN SERVICES
TO RESEARCH
WING
EYE CLINIC
SURGERY CLINICS
DF
Hood
ELEVATORS
SERVICE
STAIR #1
DumbwaiterISO
OFFICE
B323
CHAPLAIN
OFFICE
B322
CHAPLAIN
OFFICE
B321
CHAPLAIN
RECEPTION/
SECRETARY
B320 CHAPLAIN
SERVICE
B319
ELEVATOR
CORRIDOR
C3-12
WOMEN'S
TOILET
B324
MEN'S
TOILET
B324A
EUCHARISTIC
ROOM
3B168
LAB
B316C CLOSET
B316D
B316
LAB
B316B
OFFICE
B315A
OFFICE
B315
OFFICE
B312
OFFICE
B311
CONFERENCE
ROOM
B310
OFFICE
B309
OFFICE
B308
CORRIDOR
C3-11
DENTAL
RECEPTION
B307
DENTAL
WAITING
B306
HAC
B313
STOR
B314
DENTAL
CORRIDOR
C3-10A
CORRIDOR
C3-10
STO
3B169A STO
3B168A
CHAPEL
VEST.
3B171
HAC
B325
CHAPEL
3B169B
CHANCEL
3B169B
STORAGE
3B168C
SACRISTY/
STORAGE
3B169D
INTERVIEW
3B170
STAIR #3
TOILET
B326
OR
B327
CLO
B328
STAFF
B329
CLOSET
B330
CLO
B331
EXAM
B332
DENTAL
EXAM
B333
CORRIDOR
C3-13
CLO
B334
EXAM
B335
EXAM
B336
CLO
B337
DENTAL
LAB
B338
PORCELAIN
ROOM
B339
STAFF
LOUNGE
B339A
LOCKER
AREA
B339C
TOILET
ROOM
B339B
STAIR #4
CLO
B340
EXAM
B341
EXAM
B343
EXAM
B344
EXAM
B346
EXAM
B348
EXAM
B349
CLO
B342
CLO
B345
CLO
B347
STAFF
B350
STAFF
B351
OR
B352
STORAGE
B354
CLO
B353
MEN'S
ROOM
B355
WOMEN'S
ROOM
B356
CORRIDOR
C3-9C
B383
EXAM
ROOM
B382
PHOTO-
GRAPHY
ROOM
B380
CORRIDOR
C3-9D
PROCEDURE/
LASER ROOM
B379
OFFICE
B378
OFFICE
B378A OFFICE
B376
OFFICE
B374
CORRIDOR
C3-9E
EXAM
ROOM
B372
EXAM
ROOM
B370
EXAM
ROOM
B369
EXAM
ROOM
B381
EXAM
ROOM
B377
EXAM
ROOM
B375
EXAM
ROOM
B373
EXAM
ROOM
B3759
EXAM
ROOM
B361
EXAM
ROOM
B363
EXAM
ROOM
B364 EXAM
ROOM
B365
VISUAL
FIELDS
B371
VISUAL
FIELDS
B368
VISUAL
FIELDS
B366
CORRIDOR
C3-9F
CORRIDOR
C3-9B
EXAM
ROOM
B357
EXAM
ROOM
B358
EXAM
ROOM
B360
EXAM
ROOM
B362
CORRIDOR
C3-9A
CORRIDOR
C3-9
CORRIDOR
C3-9G
PASSENGER
ELEVATORS
ELEVATOR
LOBBY
C3-1
ELECTRICAL
ROOM
B367
B367A
SERVICE
ELEVATOR
LOBBY
C3-2
UNISEX
TLT RM
A342
STAFF
TLT RM
A341
CORRIDOR
C3-3
3 WEST
WAITING ROOM
A343
3 WEST
RECEPTIONIST
A345
STAIR
#5 FEC
MECHANICAL
A346
MECHANICAL
A346A
CORRIDOR
C3-4 CLOSET
A346B
CORRIDOR
C3-3A
CLO
A346C SOILED
UTILITY
A347
MEDICINE
ROOM
A348
EXAM
ROOM
A349
EXAM
ROOM
A350
EXAM
ROOM
A351
EXAM
ROOM
A352
EXAM
ROOM
A353
EXAM
ROOM
A354
CORRIDOR
C3-5
EXAM
ROOM
A355
EXAM
ROOM
A356
EXAM
ROOM
A357
EXAM
ROOM
A358
EXAM
ROOM
A359
EXAM
ROOM
A360
CAST
ROOM
A362
IMPACT
EXAM ROOM
A363
IMPACT
EXAM ROOM
A364
IMPACT
EXAM ROOM
A365
RESIDENT'S
ROOM
A300
WOMENS
ROOM
A301B
MENS
ROOM
A301A
CORRIDOR
C3-1A
TELE
A336D
TELE
A336E
CLO
A336B
CLO
A336C
FEC
ELEC
A336A
OFFICE
B300OFFICE
B301
HAC
B302
CLOSET
B303
VESTIBULE
C3-1B
RECEPTIONIST
B304
EYE
CLINIC
WAITING
B305
3 EAST
WAITING
ROOM
A301
CORRIDOR
C3-6
COMMUNICATIONS
CENTER
COUNTER
A335
CLEAN
SUPPLY
ROOM
A334
CENTRAL
EXAM
A333
CORRIDOR
C3-6A
HAC
A302
UTIL/
ELEC
A303
PROCEDURE
ROOM
A304
PODIATRY
EXAM #1
A305
PODIATRY
EXAM #2
A306
PODIATRY
EXAM #3
A307
GRINDING
ORTHODICS
A308
PODIATRY
ATTENDINGS
A309
PODIATRY
RESIDENTS
A310
PODIATRY
CHIEF
A311
PODIATRY
EXAM #4
A312
PODIATRY
EXAM #5
A313
PODIATRY
EXAM #6
A314
NURSES
WORK
ROOM
A315
SOILED
LINEN
A317
ENT STAFF
A318
ENT EXAM
ROOM #1
A319
ENT EXAM
ROOM #2
A320
ENT EXAM
ROOM #5
A321
SHARED EXAM
ROOM
A322
VASCULAR
REC/ SUPP
A323
VASCULAR
EXAM
ROOM
A324
VASCULAR
EXAM
ROOM
A325
VASCULAR
TECH OFFICE
A326
EXAM
ROOM
A327
CORRIDOR
C3-8
STERILIZ
ROOM
A328
ENT EXAM
ROOM #3
A329
ENT EXAM
ROOM #4
A330
STAFF
RESTROOM
A332 ENT
SUPPLY
A331
CORRIDOR
C3-6B
STAIR
#2
EXIST
FEC
PENTHOUSE
3D100C
CORRIDOR
C3-7
CLOSET
A363A
R a d ia to r
R a d ia to r
R a d ia to r
R a d ia to r
R a d ia to r
R a d ia to r
E E
E E
EE
EEEE
EE
EEEE
1-E-231
1-E-230
CPLIT-1-A361
NPLIT-1-A361
CPLIT-1-B317ANPLIT-1-B317A 1
St. Louis
6 South Old Orchard t: +1 800.404.7677 St. Louis, MO 63119 e: hello@introba.com www.introba.com
8718 Botts Lane Phone: (210) 816-4784
San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project TitlePhaseDrawing Title
Approved:
ARCHITECT OF RECORDCONSULTANT
Revisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
FULLY SPRINKLERED
100% BID
DOCUMENTS
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
01/16/2026
642-22-700EHRM Infrastructure Upgrades -
CMCVAMC
3900 Woodland Avenue Philadelphia, PA 19104
KEYPLAN
BLDG
BLDG
BLDG
BLDG 1 OVERALL THIRD FLOOR PLAN
BKM MS
1-E-130
1/16" = 1'-0"
BLDG 1 OVERALL THIRD FLOOR PLAN
SHEET NOTES 1-E-130
KEYED NOTES:
1 CONDUIT RISER FROM BASEMENT.
PLAN
NORTH
TRUE
PASSENGER
ELEVATORS
SERVICE
ELEVATORS
MECHANICAL
ROOM
B446A
CORRIDOR
C4-13B
SOILED
UTILITY
B446
STAFF
TOILET
B445
ENDO
B444
SCOPE CLEAN/
STORAGE
B443
ENDO
B442
CLEAN
STORAGE
B441
TECH
WORKROOM
B440
EXAM
ROOM 5
B438
STOR
B439
EXAM
ROOM 4
B437
EXAM/
OFFICE
B435
HAC
B436
EXAM/
OFFICE
B434
TRIAGE
B433
STAIR #3
ELEC
B432
ELEC
B431
SHARED GI
PROVIDER
OFFICE
B4303 PERSON
OFFICE
B429
3 PERSON
OFFICE
B428
ELEC
B427
OFFICE
B426
OFFICE
B425
OFFICE
B424
OFFICE
B423
CORRIDOR
C4-12
GI
PROVIDER
OFFICE
B422
OFFICE
B421
OFFICE
B420
OFFICE
B419
ELEVATOR
GI NURSE
STAFF
B416
SOILED
UTILITY
B415
STAFF
B414
EXAM
ROOM
B413
EXAM
ROOM
B412
EXAM
ROOM
B411
EXAM
ROOM
B410
UNISEX
TOILET
B409
H.A.C.
B408
UROLOGY
RAMP UP
TLT/ DRESSING
ROOM
B407A
CYSTOSCOPY
ROOM
B407
EQUIPMENT
CLEANING
B406
MEDICATION
ROOM
B405
EXAM
ROOM
B404
EXAM
ROOM
B403
EXAM
ROOM
B402
GI/ UROLOGY
RECEPTION
B401
CORRIDOR
C4-10A
GI/ PULMONARY
WAITING AREA
B457
TLT
B456
EXAM/
OFFICE
B455
EXAM
ROOM 3
B454
EXAM
ROOM 2
B452
CORRIDOR
C4-13
STOR
B453
GI
EXAM
ROOM 1
B451
CODE
CART
B450
PREP/
RECOVERY
B448
CORRIDOR
C4-13A
TLT
B448B
DRESS
B448A
ERCP
B447
PULMONARY
RECEPTION
B457
TELEHEALTH
B458
NEUROLOGY
OFFICE
B459
NEUROLOGY
OFFICE
B432
CORRIDOR
C4-10
UROLOGY/ GI
WAITING AREA
B400
UNISEX
TLT
B400A
UNISEX
TLT
B400B
PFT
A431
CORRIDOR
C4-9
PFT
A430 SLEEP LAB
A429
CLINICAL
RESEARCH
A433
TOUCH
DOWN
A433A
TOUCH
DOWN
A433B
EXAM/
BLOOD
DRAW
A433C
INTERVIEW
A433D
INTERVIEW
A433I
MECH
A433E
TLT
A433F
ELEVATOR
LOBBY
C4-1
ELEC
A433H
STOR
A433G
SERVICE
ELEVATOR
LOBBY
C4-2
H.C.
TLT
A435
NEUROLOGY/
PADRECC
WAITING
A472
CORRIDOR
C4-3
NEUROLOGY/
PADRECC
WAITING
A436
OFFICE
A437
ADMIN
OFFICER
A438
STOR
A439
OFFICE
A440
H.C.
TLT
A441
CORRIDOR
C4-3A
CHARTS
A442
STAIR #5
CORR.
C4-4
STOR
A443B
WORK
ROOM
A443
ELEC CLO
A443A
LAB
A445A
H.C.
TLT
A444
LAB
A445
CORRIDOR
C4-4A
OFFICE
A446
OFFICE
A447
OFFICE
A448
CHIEF
NEUROLOGY
A449
OFFICE
A451
OFFICE
A452
ADMIN
ASSIST
A450
OFFICE
A453
OFFICE
A454
SOILED
LINEN
A456
HAC
A457
EXAM
A458
EXAM
A459 EXAM
A460
EXAM
A461
EXAM
A462
STORAGE
A463
INTERVIEW
A464
EXAM
ROOM
A465
EXAM
A466EXAM
A467
EMG
EXAM
A468
EEG
EXAM
A469
CLEAN
LINEN
A470
NEUROLOGY/
PADRECC
RECEPTION
A471
OFFICE
A473
HOPTEL
ROOM #1
A400
TELE
A427B
TELE
A427C
CORRIDOR
C4-1A
DUMB
WAITER
CREDIT
UNION
A428 STAIR #1
FEC
ELEC
A427A
ELEC
A426
ELEC
CLO
A425
TOILET
A400A
TOILET
A401A
ON CALL
ROOM #2
A401
WAITING
SLEEP
LAB
A402
TLT
A424
TLT
A423A
ON CALL
ROOM #1
A423
CORRIDOR
C4-2
HOPTEL
ROOM #2
A422
TLT
A422A
CLO
A422B
TLT
A421A CLO
A421B
HOPTEL
ROOM #3
A41
STAIR
#2
FEC
H.A.C A420
CORRIDOR
C4-8
MECHANICAL
ROOM
A419
MECHANICAL
ROOM
A419A
CLEAN
LINEN
A418
D/
UTILITY
A415
CLO
A417
S/
LINEN
A416
S.C.
NURSE
A414
OFFICE/
EXAM
A413
CPAP.
SET
UP
A412
SLEEP LAB
A411
SLEEP
LAB
A409
TLT
A410
CLO
SLEEP
LAB
A408
TLT
A407
SLEEP
LAB
A406
MONITOR
RM
A405
CLO
CORRIDOR
C4-7
STO/
LINEN
A404
CORRIDOR
C4-6A
COPY
ROOM
A403
ADMIN
A403A
CORRIDOR
C4-5
CLO
TR
B418
CONFERENCE
ROOM
A455
TR
A455A
FEC
SLEEP LAB
PADRECC
O N
C A
L L
H O
P T
E L
H O
P T
E L O
N C
A L L
TO BUILDING 2
TO ROOF
TO RESEARCH WING
PULMONARY
CLINICAL RESEARCH
Radiator
R a d ia to r
Radiator Radiator Radiator
HS
H S
HS
HS
UP
DNUP
E E
E E
EE
EEEE
EE
EE
EE
1-E-241
1-E-240
CPLIT-1-A455A
NPLIT-1-A455A
CPLIT-1-B418
NPLIT-1-B418
St. Louis
6 South Old Orchard t: +1 800.404.7677 St. Louis, MO 63119 e: hello@introba.com www.introba.com
8718 Botts Lane Phone: (210) 816-4784
San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project TitlePhaseDrawing Title
Approved:
ARCHITECT OF RECORDCONSULTANT
Revisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
FULLY SPRINKLERED
100% BID
DOCUMENTS
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
01/16/2026
642-22-700EHRM Infrastructure Upgrades -
CMCVAMC
3900 Woodland Avenue Philadelphia, PA 19104
KEYPLAN
BLDG
BLDG
BLDG
BLDG 1 OVERALL FOURTH FLOOR PLAN
BKM MS
1-E-140
1/16" = 1'-0"
BLDG 1 OVERALL FOURTH FLOOR PLAN
SHEET NOTES 1-E-140
KEYED NOTES:
1 CONDUIT RISER FROM BASEMENT.
PLAN
NORTH
TRUE
R A
D R
A D
R A
D R
A D
R A
D R
A D
R A
D R
A D
R A
D R
A D
R A
D R
A D
RAD RAD
H e a d w a ll
H e a d w a ll
H e a d w a ll
Headwall
Headwall Headwall
Headwall Headwall
Headwall
H e a d w a ll
H e a d w a ll
H e a d w a ll
H e a d w a ll
H e a d w a ll
H e a d w a ll
RAD RADRAD RAD
RADRAD
TR
A502
STOR
A502A
ROOF
5 SOUTH SWING WARD
TO BUILDING 2
SURGERY TOUCHDOWN
To Research Building
EWC
PASSENGER
ELEVATORS
SERVICE
ELEVATORS
1BED
B530
1 BED
B529
1BED
B527
TLT
RM
B528
TLT
RM
B531
TOUCH
DOWN
B526
1 BED
B524
NEW
TLT RM
B524A
CLEAN
LINEN
B523
TOILET
ROOM
B518A
SOILED
LINEN
B521
HAC
B520
CLO
B522
1 BED
B516
2 BEDS
B515
TOILET ROOM
B514
2 BEDS
B513
2 BEDS
B512
TOILET ROOM
B511
2 BEDS
B510
MEDICATION
ROOM
B508
TLT
B508A
STORAGE
B507
STORAGE
B506
TOILET
ROOM
B503A
NORISH-
MENT
KITCHEN
B505
2 BEDS
B503
TOUCH
DOWN
B502
QUALITY
MANAGEMENT
B501
CASE
MANAGERS
A534
SOCIAL
WORK
A533
PHARMACY
OFFICE
A532
DUMB
WAITER
STAIR # 1
A528
2 BEDS
CLO
A527
TLT
A528A
CL
A526
CL
A525
TLT
A524A
A524
SINGLE
BED
CLO
A523
STORAGE
A522A
STORAGE
A522B
CLO
A521
CL
A520
STORAGE
A522C TLT
A519A
2BED
A519
DAY
ROOM
A518
STAFF
LOCKER
ROOM
A517
A BED
ISOLATION
A516
ANTE
A516A
TLT
A516B
1 BED
ISOLATION
A515
TLT
A515B
ANTE
A515A
TLT
A514B
ANTE
A514A
1 BED
ISOLATION
A514
STOR
A513
SOILED
A512
CLEAN
A511
MED.
A510 2 BEDS
A509 TLT
A508A
TLT
A509A
2 BEDS
A508
STORAGE
A507
2BED
A506
TLT
A506A
TLT
A505A
2 BEDS
A505A504B5 EAST
NURSE STATION
A504
A504A
ANTE
ROOM
A503A
1 BED
ISOLATION
A503
TLT
A503B
HEAD NURSE
OFFICE
A571
NURSE'S
WORKROOM
A570
STAFF
ROOM
A569
REHAB
WORKROOM
A568
CHARTING
ROOM
A567
5 WEST
NURSE
STATION
A566
A566A SEMI- PRIVATE
A565
TLT
A565A
STORAGE
A564
TLT
A563A
RADIATION
TREATMENT
ROOM
A563
VESTIBULE
C5-9
RADIATION
TREATMENT
ROOM
A562
TLT
A562A
TLT
A560A
STORAGE
A561
SEMI-PRIVATE
A560
CORRIDOR
C5-8
CORRIDOR
C5-7
MED.
RM.
A559
NOURISH-
MENT
A558
DIRTY
UTILITY
A557LAUNDRY
CHUTE
ELEC.
A556
JAN.
A555
SEMI- PRIVATE
A554
TLT
A553A
TLT
A554A
SEMI-
PRIVATE
A553
TLT
A551
STOR
A552
SEMI-PRIVATE
A551STORAGE
A550
DAY
ROOM
A549
SEMI-
PRIVATE
A548
STOR
A545A
TLT
A548A
ELEC
A547
CORRIDOR
C5-10
STORAGE
A546
CONGREGATE
BATH
A545
STAIR
S5
PRIVATE
A544
TLT
A544A
CLEAN
LINEN
A543
CLEAN
LINEN
A542TLT
A541A
CORRIDOR
C5-6
SEMI-PRIVATE
A541
STAFF
TLT
A540
PATIENT
STORAGE
A539
TELEHEALTH
A538H
TLT RM
A538G
CLO
A538I
FMS
CLO
A538J
TELPHONE
A537C
TELEPHONE
A537BELEVATOR LOBBY
C5-1
TOUCH
DOWN
A538F
TOUCH
DOWN
A538E
MECH
A538DTOUCH
DOWN
A538C
MOD F
STORAGE
A538B
SURGERY
TOUCH
DOWN
A538
TOUCH
DOWN
A538A
SPS TEMP
CLEANING
B546
TLT RM
B546ASTAFF
ROOM
B545
CLEAN
STORAGE
B540B
PATIENT TLT
B544
5 SOUTH
NURSE STATION
B540A
STORAGE
B539
ELEC
B538
STAIR #3
ANTE-
ROOM
B535
OLD
TLT
B535B
CHEMO
CONTINGENCY
B535A
CONGREGATE
BATH
B534
ELE
B533
1 BED
B532
FAN ROOM
ELEC
A537
ELEC
A536
ELEC
A535
FEC
A537A
E E
EE
EE
EE
1-E-250
CPLIT-1-A502NPLIT-1-A502
St. Louis
6 South Old Orchard t: +1 800.404.7677 St. Louis, MO 63119 e: hello@introba.com www.introba.com
8718 Botts Lane Phone: (210) 816-4784
San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project TitlePhaseDrawing Title
Approved:
ARCHITECT OF RECORDCONSULTANT
Revisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
FULLY SPRINKLERED
100% BID
DOCUMENTS
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
01/16/2026
642-22-700EHRM Infrastructure Upgrades -
CMCVAMC
3900 Woodland Avenue Philadelphia, PA 19104
KEYPLAN
BLDG
BLDG
BLDG
BLDG 1 OVERALL FIFTH FLOOR PLAN
BKM MS
1-E-150
1/16" = 1'-0"
BLDG 1 OVERALL FIFTH FLOOR PLAN
SHEET NOTES 1-E-150
KEYED NOTES:
1 CONDUIT RISER FROM BASEMENT.
PLAN
NORTH
TRUE
R A
D R
A D
R A
D R
A D
R A
D R
A D
R A
D R
A D
R A
D R
A D
R A
D R
A D
RAD RAD
H e a d w a ll
H e a d w a ll
H e a d w a ll
FEC
EWC
PASSENGER
ELEVATORS
SERVICE
ELEVATORS
RENAL
EXAM
B624
B623A
RENAL
EXAM
B623
RENAL
LAB
B622
RENAL EXAM
NURSING
B621
HAC
B620
CLO
B619
SOILED
LINEN
B618
CORRIDOR
C6-10A
TLT RM
B617A
STORAGE
B617
SUPPLIES
B616
TLT
B616A
WORK
AREA
B615 TLT
B615A
CORRIDOR
C6-11
NURSE
STATION
B611A
HEMODIALYSIS
B611
ISOLATION
B610
TOUCH
DOWN
B609
TLT
B609A
OFFICE
B608
TLT
B608A
STORAGE
B607
TLT
B603A
NOURISH-
MENT
B606
CLEAN
LINEN
B605
RESPIRATORY
CARE
EQUIP.
B604
EPO
B603 CASE
MANAGERS
B602
PHARMACY
OFFICE
B601
CLINICAL
DIETITIONS
A635
DIALYSIS
OFFICE
A634
TLT
A634A
NURSING
OFFICE
A632
DUMB
WAITER
STAIR
#1 ELEC
A629
FEC
A631A
ELECTRIC
A631
CLO
A630
2 BEDROOM
PATIENT
ROOM
A628
TLT
A628A
TLT
A624A
STAFF
TLT
A627
CLEAN
LINEN
A626
CLEAN
UTILITY
A625
1 BEDROOM
PATIENT
ROOM
A624
STAIR
#2
FEC
TELE
CLO
A623
CONGREGATE
BATH
A622
STOR
CLO
A622
TLT
A619A
ELEC
A621
ELEC
A620
2 BEDROOM
PATIENT
ROOM
A619
HOSPITALISTS
A618
NEW DAY ROOM
A617
1 BEDROOM
ISOLATION
ROOM
A616
ANTE-
ROOM
A616A
TLT
A616A
1 BEDROOM
ISOLATION
ROOM
A615
TLT
A615B
ANTE-
ROOM
A615A
TLT
A614B
ANTE-
ROOM
A614A
1 BEDROOM
ISOLATION ROOM
A614
HAC
A613
SOILED
UTILITY
A612
NOURISH-
MENT
ROOM
A611
MEDICATION
ROOM
A610
2 BEDROOM
PATIENT ROOM
A609 TLT
A608A
TLT
A609A 2 BEDROOM
PATIENT ROOM
A608
STORAGE
ROOM
A607
2 BEDROOM
PATIENT ROOM
A606
TLT
A606A
TLT
A605A
2 BEDROOM
PATIENT ROOM
A605
A604B
NURSE
STATION
A604
NURSE
STATION
A604A
ANTE-
ROOM
A603A
CORRIDOR
C6-6
1 BEDROOM
ISOLATION ROOM
A603
TLT
A603B
NURSING
OFFICE
A602
HEAD NURSE
OFFICE
A669
NURSE
WORKROOM
A668
RESIDENT'S
ROUNDING ROOM
A667
NURSE
STATION
A666
A666A
2 BEDROOM
PATIENT ROOM
A665
TLT
A663A
TLT
A665A
2 BEDROOM
PATIENT ROOM
A663
ASST.
NURSE
MGR
A662
2 BEDROOM
PATIENT ROOM
A661
TLT
A661A
TLT
A660A
2 BEDROOM
PATIENT ROOM
A660
MEDICATION
ROOM
A659
NOURISH-
MENT
ROOM
A658
DIRTY
UTILITY
A657LAUNDRY
CHUTE
ELEC
A656
HAC
A655
2 BEDROOM
PATIENT ROOM
A654
TLT
A653A
TLT
A654A
2 BEDROOM
PATIENT ROOM
A653
STOR
ROOM
A652
TLT
A651A
2 BEDROOM
PATIENT ROOM
A651
STOR
ROOM
A650
DAY
ROOM
A649
2 BEDROOM
PATIENT ROOM
A648
STOR
ROOM
A645A
TLT
A648A ELEC
A647
STORAGE
ROOM
A646CONGREGATE
BATH
A645
STAIR
#5
1 BEDROOM
PATIENT ROOM
A644
TLT
A644A
CLEAN
LINEN
A643
TLT
A641A
TELE
ROOM
A642
2 BEDROOM
PATIENT ROOM
A641
STOR
A639
STAFF
TLT
A640
SERVICE
ELEVATORS
C6-2CLO
A638A
ELEC
A638B
RESIDENT'S
WORKROOM
A639B
OFFICE
A637B
VOLUNTARY
A637
OFFICE
A637A
ELEVATOR LOBBY
C6-1
TELEPHONE
A631C
TELEPHONE
A631B
CORRIDOR
C6-9
VOLUNTARY
STORAGE
A636
ESCORT
SERVICE
B639
TLT
B639ARENAL
NURSE
B638
CORRIDOR
C6-10
STAFF
TLT
B637
OFFICE
B636
DIALYSIS/
RENAL
RECEPTION
B634
DIALYSIS
STORAGE
B634A
MECHANICAL
ROOM
B633
ELEC
B632FEC
B631
STAIR #3
ANTE
B629
RENAL
EXAM ROOM
B629A
TLT
B629B
MEDICAL
STAFF
OFFICE
STORAGE
B628
CLO
B627
CORRIDOR
C6-12
RENAL
EXAM
B626B625A
RENAL
EXAM
B625
CORRIDOR
C6-1A
TR
A601
LIFT
TO BUILDING 2
ROOF
BUILT UP ROOF
Printer
H e a d w a ll
U n it
RadiatorRadiatorRadiatorRadiator
Radiator Radiator Radiator Capped Steam Pipes
E E
EE
EE
EE
1-E-260
CPLIT-1-A601NPLIT-1-A601
St. Louis
6 South Old Orchard t: +1 800.404.7677 St. Louis, MO 63119 e: hello@introba.com www.introba.com
8718 Botts Lane Phone: (210) 816-4784
San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project TitlePhaseDrawing Title
Approved:
ARCHITECT OF RECORDCONSULTANT
Revisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
FULLY SPRINKLERED
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .