S02 - 892CM3036 - Binder 9 of 9 Miramar.pdf
PDF 13 MB Posted
- Solicitation number
- 36C78620B0015
About this file
This document provides details on a federal contract opportunity from the Department of Veterans Affairs National Cemetery Administration. The solicitation seeks bids for the Miramar National Cemetery Expansion project to provide columbarium niches and in-ground cremains. The project number is 892-036 with a solicitation number of 36C78620B0015. Bids are due by the response date to support expanding services at the Miramar National Cemetery in San Diego, California.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
0 38
390 379 379
Revisions Date
Approved: Director, Project Management Service
Approved: Director, Office of Construction Management
Drawing Title
OfDwg.
Building Number
Location
Project Title
Checked
DRAWING NO.
Project No.
Date
Drawn
892CM3036
Pl ott ed : 6
/4/ at
:30 pm
B y:
Ch els ea .A nd er ss on
Fil e:
S:
\A cti ve
Jo b F ile s\V
A Mi ra ma r N ati on al
Ce me ter y 1
A\
CA
D\
-C D\
RH
AA
\P lot
\LK
1-
LK
6 S ign ag e P lan
.dw g
ENGINEER OF RECORDCONSULTANTS
TERRACON
1421 EDINGER AVENUE, SUITE C
TUSTIN CA 92780
2 2 5 M i l l e r A v e n u e , M i l l V a l l e y , C A 9 4 9 4 1
T 415 383 7900 F 415 383 1433 www.rhaa.com
MIRAMAR NATIONAL CEMETERY
5795 NOBEL DRIVE
SAN DIEGO, CALIFORNIA 92122
COLUMBARIUM AND CREMAINS
EXPANSION
ENGINEERED WITH LAYTON
1490 S PRICE RD, SUITE 215
CHANDLER, AZ 85286
MARCH 2020
BID DOCUMENTS
NOT FOR CONSTRUCTION
LK104
S E
E
S
H E
E T
L
S E
E
S
H E
SIGNAGE PLAN 4
LK106 LK101
LK102
LK103
LK104 LK105
1"=600'
KEY MAP
DWG. 104 OF 127
1 381
2 37
3 37
6 37
7 37
Revisions Date
Approved: Director, Project Management Service
Approved: Director, Office of Construction Management
Drawing Title
OfDwg.
Building Number
Location
Project Title
Checked
DRAWING NO.
Project No.
Date
Drawn
892CM3036
Pl ott ed : 6
/4/ at
:31 pm
B y:
Ch els ea .A nd er ss on
Fil e:
S:
\A cti ve
Jo b F ile s\V
A Mi ra ma r N ati on al
Ce me ter y 1
A\
CA
D\
-C D\
RH
AA
\P lot
\LK
1-
LK
6 S ign ag e P lan
.dw g
ENGINEER OF RECORDCONSULTANTS
TERRACON
1421 EDINGER AVENUE, SUITE C
TUSTIN CA 92780
2 2 5 M i l l e r A v e n u e , M i l l V a l l e y , C A 9 4 9 4 1
T 415 383 7900 F 415 383 1433 www.rhaa.com
MIRAMAR NATIONAL CEMETERY
5795 NOBEL DRIVE
SAN DIEGO, CALIFORNIA 92122
COLUMBARIUM AND CREMAINS
EXPANSION
ENGINEERED WITH LAYTON
1490 S PRICE RD, SUITE 215
CHANDLER, AZ 85286
MARCH 2020
BID DOCUMENTS
NOT FOR CONSTRUCTION
LK105
S E
E
S
H E
SIGNAGE PLAN 5
LK106 LK101
LK102
LK103
LK104 LK105
1"=600'
DWG. 105 OF 127
N
O
P
A
R
K
I
N
G
Revisions Date
Approved: Director, Project Management Service
Approved: Director, Office of Construction Management
Drawing Title
OfDwg.
Building Number
Location
Project Title
Checked
DRAWING NO.
Project No.
Date
Drawn
892CM3036
Pl ott ed : 6
/4/ at
:31 pm
B y:
Ch els ea .A nd er ss on
Fil e:
S:
\A cti ve
Jo b F ile s\V
A Mi ra ma r N ati on al
Ce me ter y 1
A\
CA
D\
-C D\
RH
AA
\P lot
\LK
1-
LK
6 S ign ag e P lan
.dw g
ENGINEER OF RECORDCONSULTANTS
TERRACON
1421 EDINGER AVENUE, SUITE C
TUSTIN CA 92780
2 2 5 M i l l e r A v e n u e , M i l l V a l l e y , C A 9 4 9 4 1
T 415 383 7900 F 415 383 1433 www.rhaa.com
MIRAMAR NATIONAL CEMETERY
5795 NOBEL DRIVE
SAN DIEGO, CALIFORNIA 92122
COLUMBARIUM AND CREMAINS
EXPANSION
ENGINEERED WITH LAYTON
1490 S PRICE RD, SUITE 215
CHANDLER, AZ 85286
MARCH 2020
BID DOCUMENTS
NOT FOR CONSTRUCTION
LK106
SIGNAGE PLAN 6 (ADD ALT 3)
LK106 LK101
LK102
LK103
LK104 LK105
1"=600'
DWG. 106 OF 127
B F
B F
Revisions Date
Approved: Director, Project Management Service
Approved: Director, Office of Construction Management
Drawing Title
OfDwg.
Building Number
Location
Project Title
Checked
DRAWING NO.
Project No.
Date
Drawn
892CM3036
Pl ott ed : 6
/4/ at
:31 pm
B y:
Ch els ea .A nd er ss on
Fil e:
S:
\A cti ve
Jo b F ile s\V
A Mi ra ma r N ati on al
Ce me ter y 1
A\
CA
D\
-C D\
RH
AA
\P lot
\LK
1 S ign ag e E nla rg em en t P lan
.dw g
ENGINEER OF RECORDCONSULTANTS
TERRACON
1421 EDINGER AVENUE, SUITE C
TUSTIN CA 92780
2 2 5 M i l l e r A v e n u e , M i l l V a l l e y , C A 9 4 9 4 1
T 415 383 7900 F 415 383 1433 www.rhaa.com
MIRAMAR NATIONAL CEMETERY
5795 NOBEL DRIVE
SAN DIEGO, CALIFORNIA 92122
COLUMBARIUM AND CREMAINS
EXPANSION
ENGINEERED WITH LAYTON
1490 S PRICE RD, SUITE 215
CHANDLER, AZ 85286
MARCH 2020
BID DOCUMENTS
NOT FOR CONSTRUCTION
LK401
SIGNAGE PLAN -
COLUMBARIA ENLARGEMENT
DWG. 107 OF 127
Revisions Date
Approved: Director, Project Management Service
Approved: Director, Office of Construction Management
Drawing Title
OfDwg.
Building Number
Location
Project Title
Checked
DRAWING NO.
Project No.
Date
Drawn
892CM3036
Pl ott ed : 6
/4/ at
:32 pm
B y:
Ch els ea .A nd er ss on
Fil e:
S:
\A cti ve
Jo b F ile s\V
A Mi ra ma r N ati on al
Ce me ter y 1
A\
CA
D\
-C D\
RH
AA
\P lot
\LK
1-
LK
5 S ign ag e D eta ils .dw g
ENGINEER OF RECORDCONSULTANTS
TERRACON
1421 EDINGER AVENUE, SUITE C
TUSTIN CA 92780
2 2 5 M i l l e r A v e n u e , M i l l V a l l e y , C A 9 4 9 4 1
T 415 383 7900 F 415 383 1433 www.rhaa.com
MIRAMAR NATIONAL CEMETERY
5795 NOBEL DRIVE
SAN DIEGO, CALIFORNIA 92122
COLUMBARIUM AND CREMAINS
EXPANSION
ENGINEERED WITH LAYTON
1490 S PRICE RD, SUITE 215
CHANDLER, AZ 85286
MARCH 2020
BID DOCUMENTS
NOT FOR CONSTRUCTION
LK501
SIGNAGE DETAILS 1
DWG. 108 OF 127
Approved: Director, Office of Construction Management
Drawing Title
OfDwg.
Building Number
Location
Project Title
Checked
DRAWING NO.
Project No.
Date
Drawn
892CM3036
Pl ott ed : 6
/4/ at
:32 pm
B y:
Ch els ea .A nd er ss on
Fil e:
S:
\A cti ve
Jo b F ile s\V
A Mi ra ma r N ati on al
Ce me ter y 1
A\
CA
D\
-C D\
RH
AA
\P lot
\LK
1-
LK
5 S ign ag e D eta ils .dw g
ENGINEER OF RECORDCONSULTANTS
TERRACON
1421 EDINGER AVENUE, SUITE C
TUSTIN CA 92780
2 2 5 M i l l e r A v e n u e , M i l l V a l l e y , C A 9 4 9 4 1
T 415 383 7900 F 415 383 1433 www.rhaa.com
MIRAMAR NATIONAL CEMETERY
5795 NOBEL DRIVE
SAN DIEGO, CALIFORNIA 92122
COLUMBARIUM AND CREMAINS
EXPANSION
ENGINEERED WITH LAYTON
1490 S PRICE RD, SUITE 215
CHANDLER, AZ 85286
MARCH 2020
BID DOCUMENTS
NOT FOR CONSTRUCTION
LK502
SIGNAGE DETAILS 2
Speed Limit
One
Way
Committal Shelter C
Columbarium T-AAColumbarium T-AACommittal Shelter C
1 3
Corteges
All
Funerals
Wait Here
Cemetery
Vehicles
Only
DO NOT
ENTER
DO
NOT
DRINK
NO
BEBER
Committal Shelter C
Road X
M onsoor A venue
M onsoor A venue
DWG. 109 OF 127
Approved: Director, Office of Construction Management
Drawing Title
OfDwg.
Building Number
Location
Project Title
Checked
DRAWING NO.
Project No.
Date
Drawn
892CM3036
Pl ott ed : 6
/4/ at
:32 pm
B y:
Ch els ea .A nd er ss on
Fil e:
S:
\A cti ve
Jo b F ile s\V
A Mi ra ma r N ati on al
Ce me ter y 1
A\
CA
D\
-C D\
RH
AA
\P lot
\LK
1-
LK
5 S ign ag e D eta ils .dw g
ENGINEER OF RECORDCONSULTANTS
TERRACON
1421 EDINGER AVENUE, SUITE C
TUSTIN CA 92780
2 2 5 M i l l e r A v e n u e , M i l l V a l l e y , C A 9 4 9 4 1
T 415 383 7900 F 415 383 1433 www.rhaa.com
MIRAMAR NATIONAL CEMETERY
5795 NOBEL DRIVE
SAN DIEGO, CALIFORNIA 92122
COLUMBARIUM AND CREMAINS
EXPANSION
ENGINEERED WITH LAYTON
1490 S PRICE RD, SUITE 215
CHANDLER, AZ 85286
MARCH 2020
BID DOCUMENTS
NOT FOR CONSTRUCTION
LK503
SIGNAGE DETAILS 3
FLORAL
REGULATIONS
ENLARGEMENT FLORAL REGULATIONS
NTS
1. Fresh cut flowers may be placed on graves at any time. Temporary flower containers are available.
2. Floral items will be removed from graves as soon as they become faded or unsightly.
3. Artificial flowers may be placed on graves during the period of October 1 through April 1.
4. Plantings will not be permitted on graves at any time. potted plants will be permitted on graves only during the period 10 days before and 10 days after Easter Sunday, Memorial Day, Veterans Day, and Christmas.
5. Christmas wreaths or grave blankets are permitted on graves from December 15 through January 10 and will be removed not later than January 20 of each year. Grave floral blankets may not be larger than two by three feet.
6. During lawn mowing and ground maintenance season, all floral items will be removed from the graves on the 1st and 15th of each month, or sooner if necessary.
7. Statues, vigil lights, breakable objects of any nature, and similar commemorative items are not permitted on graves at any time.
8. Floral items and other types of decorations will not be secured to headstones or markers.
Flower Vases Flower Vases Flower Vases Flower Vases
Trash Trash Trash Trash
Recycle Recycle Recycle Recycle
Flow
DWG. 110 OF 127
Approved: Director, Office of Construction Management
Drawing Title
OfDwg.
Building Number
Location
Project Title
Checked
DRAWING NO.
Project No.
Date
Drawn
892CM3036
Pl ott ed : 6
/4/ at
:32 pm
B y:
Ch els ea .A nd er ss on
Fil e:
S:
\A cti ve
Jo b F ile s\V
A Mi ra ma r N ati on al
Ce me ter y 1
A\
CA
D\
-C D\
RH
AA
\P lot
\LK
1-
LK
5 S ign ag e D eta ils .dw g
ENGINEER OF RECORDCONSULTANTS
TERRACON
1421 EDINGER AVENUE, SUITE C
TUSTIN CA 92780
2 2 5 M i l l e r A v e n u e , M i l l V a l l e y , C A 9 4 9 4 1
T 415 383 7900 F 415 383 1433 www.rhaa.com
MIRAMAR NATIONAL CEMETERY
5795 NOBEL DRIVE
SAN DIEGO, CALIFORNIA 92122
COLUMBARIUM AND CREMAINS
EXPANSION
ENGINEERED WITH LAYTON
1490 S PRICE RD, SUITE 215
CHANDLER, AZ 85286
MARCH 2020
BID DOCUMENTS
NOT FOR CONSTRUCTION
LK504
SIGNAGE DETAILS 4
DO NOT
DRINK
Van Accessible Min Fine
$250
Parking Only
Min Fine $250
DWG. 111 OF 127
SERVICE ACCESS PATH
-SEE LANDSCAPE DRAWINGS
1 2 3 4
1 2 3 4
C
B
A
C
B
A
72'-0"
21'-0" 10'-0" 10'-0" 10'-0" 21'-0"
6' -1
0"
'-0
7' -2
'-1
0"
72'-0"
21'-0" 10'-0" 10'-0" 10'-0" 21'-0"
F5
F2
D5
F8
B5
D8
F1
D2
'-1
0"
6' -1
0"
'-0
7' -2
1' -2
1'
-2
13'-10" 1'-2" 1'-2"
1 2 3 4
1 2 3 4
C
B
A
C
B
A
10'-0" 10'-0" 10'-0"
6' -1
0"
'-0
10'-0" 10'-0" 10'-0"
F2
F8
'-1 0"
6' -1
0"
'-0
7' -2
EQ. EQ.
2' -4
1' -2
9' -1
0" 3'
-6
5'-0" 5'-0"
1'-2"
1'-2"
1' -2
2'
-4
NO RAIN CHAIN AT THIS
SPLASH BLOCK ONLY
-POSITION SPLASH BLOCK ON
GRADE BELOW SCUPPER
SB
SBSB
SB SB
ROOF OVERHANG
SLAB EDGE
BATTERED PILASTER
LOW WALL W/ BATTERED END
BIER, V V
6'-0" STEEL BENCH,
VICTOR STANLEY
MODEL RB-28
SPLASH BLOCK, TYP.
SEE DETAIL
COBBLE ON GRADE-TYPICAL
SEE LANDSCAPE DRAWINGS
SIDEWALK
SEE LANDSCAPE DRAWINGS
COMMITTAL
SHELTER
36x32 UNDER ROOF
7' -1
0" 1'
-2
6' -0
STORAGE
64 SF
1A
4803 4803
R21'-9"
6'-0" 6'-0"
B6
B3
FLOOR PLANE6 SCALE: 18" = 1'-0"
0 2' 4' 8' 16'
WOOD CEILING
STEEL BEAM-SEE
STRUCTURAL
PAINT EXPOSED
STEEL P-3
CEMENT PLASTER
SOFFIT & FASCIA
METAL SOFFIT
SIMILAR W/ WOOD
CEILING IN LIEU OF
METAL SOFFIT
NO
RTH
CEILING SURFACE
EXPOSED FLUORESCENT
STRIP LIGHTROOF ABOVE
3'-0" 3'-0"
36'-0"
4' -0
4'
-0
'-0
"35 '-8
3'-0" 3'-0"
36'-0"
4' -0
4'
-0
'-0
REFLECTED CEILING PLANE2 SCALE: 18" = 1'-0"
0 2' 4' 8' 16'
NO
RTH
1 2 3 4
1 2 3 4
C
B
A
C
B
A
10'-0" 10'-0" 10'-0"
6' -1
0"
'-0
10'-0" 10'-0" 10'-0"
F2
F8
6' -1
0"
'-0 "B2
ROOF PARAPET BELOW
(CUT STONE W/ BIRD WIRE)
TYPICAL CURVED
GABLE @ STANDING
SEAM METAL ROOF
TYPICAL DETAIL OF
CUT STONE CAP @
PCP WALL
3'-0" 3'-0"
36'-0"
4' -0
4'
-0
'-0
"35 '-8
3'-0" 3'-0"
36'-0"
4' -0
4' -0
'-0
ROOF PLANB6 SCALE: 18" = 1'-0"
0 2' 4' 8' 16'
NO
RTH
CUT STONE W/ BIRD WIRE, TYPICAL
MEMBRANE ROOFING
1/4"/FOOT SLOPE
LOW POINT
1.00" THICK RIGID INSULATION
SCUPPER-SEE D4/4803-501
GUTTER DRAIN W/ RAIN CHAIN
CUT STONE COLUMN CAP-TYPICAL
B8
HIGH POINT
GUTTER
HIGH POINT
2.92" THICK RIGID
INSULATION
B8
F4
F2
B8
4803 4803
HIGH POINT
3.08" THICK RIGID
INSULATION
TYPICAL DETAIL @
STANDING SEAM
METAL ROOF GUTTER
ROOF CREST
TYPICAL CURVED
GABLE @ STANDING
SEAM METAL ROOF
B2
B2
HIGH POINT
GUTTER
GUTTER DRAIN
W/ RAIN CHAIN
HIGH POINT
GUTTER
9"
'-0
1'-6"-TYP. SEAM
C U
R
VE
D
SL
O
PE
C U
R
VE
D
SL
O
PE
TYPICAL UP-SLOPE
COLUMN @ STANDING
SEAM METAL ROOF
TYPICAL SIDE
@ STANDING SEAM
METAL ROOF @ MFD
MASONRY COLUMN
GUTTER DRAIN
W/ RAIN CHAIN
HIGH POINT
GUTTER
GUTTER DRAIN
W/ RAIN CHAIN
HIGH POINT
GUTTER
'-0
HIGH POINT
GUTTER
APPLICABLE CODE: INTERNATIONAL BUILDING CODE 2018
BUILDING CODE REVIEW:
1.
OCCUPANCY CLASSIFICATION2.
2.1 ASSEMBLY
2.2 GROUP A-3
HEIGHT AND AREA LIMITATIONS3.
3.1 MAXIMUM ALLOWABLE HEIGHT: 1 STORY (40 FT.)
3.2 ACTUAL HEIGHT: 1 STORY (APPROX. 16 FT.)
3.3 MAXIMUM ALLOWABLE AREA: 6,000 S.F.
3.4 ACUTAL AREA: APPROX. 1,152 S.F.
TYPE OF CONSTRUCTION: TYPE VB CONSTRUCTION, BUILDING
ELEMENTS ARE ANY MATERIAL PERMITTED BY CODE.
4.
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING
ELEMENTS: NONE
5.
AUTOMATIC SPRINKLER SYSTEMS: NOT REQUIRED, NOT PROVIDED.6.
MEANS OF EGRESS7.
7.1 MAXIMUM FLOOR AREA ALLOWANCE PER OCCUPANT
7.1.1 INTENDED USE FOR 60 OCCUPANTS IN AN
UNENCLOSED, OPEN AIR PAVILION STRUCTURE.
CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND CONDITIONS
SHOWN AND REPORT ANY DISCREPENCIES TO THE RISIDENT
ENGINEER IMMEDIATELY FOR RESOLUTION PRIOR TO PROCEEDING.
GENERAL NOTES:
1.
SEE NOTES, THIS SHEET, FOR LEED-NC 2.2 SS CREDIT 7.2 HEAT
ISLAND EFFECT: ROOF
2.
FOR REFERENCE ONLY: RECYCLING COLLECTION AS RELATED TO
LEED-NC 2.2 CREDIT MR PREREQUISITE 1: STORAGE AND
COLLECTION OF RECYCLABLES, IS PROVIDED NEAR BUILDING 4803
PER LANDSCAPING SHEETS. REFER TO NOTE, THIS SHEET FOR
ADDITIONAL INFORMATION.
3.
SLOPE MEMBRANE ROOFING 1/4 " PER FOOT.4.
GUTTERS SHALL SLOPE TO GUTTER DRAIN 1/16" PER FOOT.
PROVIDE RAIN CHAIN AT EACH GUTTER DRAIN AND SPLASH BLOCKS
WHERE INDICATED BY ROOF PLAN AND FLOOR PLAN.
5.
ROOF PLAN LEGEND
CUT STONE SCUPPER
SEE DETAIL
DIRECTION OF SLOPE
DOOR
NUMBER
DOOR SCHEDULE
LOCATION DOOR TYPE DOOR SIZE DOOR FRAME HARDWARE
SET
NUMBER
REMARKS
101A 101 STORAGE C (2) 3'-0" X 7'-0" X 1 3/4"
MATERIAL FINISH
GALVANIZED
HOLLOW METAL
PAINT
MATERIAL
GALVANIZED
HOLLOW METAL
PAINT
FINISH FRAME
TYPE
HEAD
DETAIL
JAMB
DETAIL
2 B2/ 4803-504
B4 & D4 4803-504
NOTES:
1. SEE SHEET 4803-504 FOR DOOR AND FRAME TYPES
2. "PAINT" MEANS "PAINT TO MATCH ADJACENT WALL."
3. GALVANIZED HOLLOW METAL DOORS SHALL BE INSULATED.
4. SEE SECTION 08 71 00 FOR HARDWARE SETS.
ROOM FINISH SCHEDULE
ROOM FLOOR
WALLS
BASE WAINSCOT CEILING
FINISHES
100 COMMITTAL SHELTER
101 STORAGE
CONC.
CONC.
NORTH EAST SOUTH WEST
SEE ELEVATIONS ON SHEET 4803-200
EXPOSED PLYWOOD N/A N/A N/A
WD-2/STAIN; P-3
EXPOSED STEEL
FINISH LEGEND:
CPT CARPET TILE
P PAINT
CONC CONCRETE (SEALED)
N/A NOT APPLICABLE
VSF VINYL SHEET FLOORING
AT ACOUSTIC TILE
VB VINYL BASE
CT CERAMIC TILE
GWB GYPSUM WALL BOARD
WD WOOD
STN STAIN
Revisions Date
Approved: Director, Project Management Service
Approved: Director, Office of Construction Management
Drawing Title
OfDwg.
Building Number
Location
Project Title
Checked DRAWING NO.
Project No.
Date
Drawn
892CM3036
Pl ott ed : 5
/11 /20 at 9:
am
B y:
jsu nw oo Fil e:
L:\
1.0
Pr oje cts \20
-0
4 -
M ira ma r N
C Ph as e I
I\A
CA
D\ Pl an s\B id Do cs \A rch ite ctu ra l D wg s\4
3-
1-
CO
MM
IT
TA
L S
ER
VI
CE
S
HE
LT
ER
.dw g
ENGINEER OF RECORDCONSULTANTS
BID DOCUMENTS
TERRACON
1421 EDINGER AVENUE, SUITE C
TUSTIN CA 92780
(949) 383-1990
2 2 5 M i l l e r A v e n u e , M i l l V a l l e y , C A 9 4 9 4 1 T 415 383 7900 F 415 383 1433 www.rhaa.com
MAY 2020
MIRAMAR NATIONAL CEMETERY
5795 NOBEL DRIVE
SAN DIEGO, CALIFORNIA 92122
COLUMBARIUM AND CREMAINS
EXPANSION
ENGINEERED WITH LAYTON
1490 S PRICE RD, SUITE 215
CHANDLER, AZ 85286 NA NEL JHS
COMMITTAL SERVICE SHELTER
FLOOR PLAN, ROOF PLAN
& CEILING PLAN
A-101
DWG. 112 OF 127
CUT STONE CAP
BATTERED COLUMN
W/ MANUFACTURED
MASONRY
STANDING SEAM
METAL ROOF
BIRD WIRE
CUT STONE CAP
CUT STONE SCUPPER,
SEE D4/4803-501
PORTLAND CEMENT PLASTER
CUT STONE WATER TABLE
GRADE
CUT STONE BASE
CUT STONE CAP
R
'-9
CUT STONE BASE
CONTROL
JOINT
F2
TOP OF ROOF BEAM
TOP OF CAST STONE
16'-0"
BOTTOM OF GUTTER
12'-2"
TOP OF CUT STONE
9'-0"
TOP OF CUT STONE
3'-0"
TOP OF SLAB
0'-0"
ELEV. @ STORAGE RM.
@ BUILDING 4803 (REFER TO
GRADING PLANS
NOTE: ROOF RADIUS SHOWN
SHALL BE TAKEN AT TOP OF
STRUCTURAL ROOF BEAM
RIGHT SIDE ELEVATIOND8 SCALE: 18" = 1'-0"
0 2' 4' 8' 16'
F8
FRONT ELEVATIOND5 SCALE: 18" = 1'-0"
0 2' 4' 8' 16'
TOP OF ROOF BEAM
TOP OF CAST STONE
16'-0"
BOTTOM OF GUTTER
12'-2"
TOP OF CUT STONE
9'-0"
TOP OF CUT STONE
3'-0"
TOP OF SLAB
0'-0"
ELEV. @ STORAGE RM.
@ BUILDING 4803 (REFER TO
GRADING PLANS
CUT STONE CAP
GUTTERSTANDING SEAM
METAL ROOF
WOOD CEILING
RAIN CHAIN
PORTLAND CEMENT PLASTER
BATTERED COLUMN
W/ MANUFACTURED MASONRY
TYPICAL BATTERED LOW
WALL, FORM SLOPED
SUBSTRATE W/ CMU AND
CONCRETE-SIMILAR 1/S-503
SEE B5/4803-300 FOR
ADDITIONAL INFORMATION
SIDEWALK
CONCRETE SLAB
GRADE
MANUFACTURED MASONRY
ON CMU LOW WALL-TYP.
CUT STONE BASE
CONTROL
JOINTS
BIRD
WIRE
CUT STONE BASE
CUT STONE CAP
CUT STONE
CAP
R 35'-9"
CUT STONE BASE
CONTROL
JOINT
F2
TOP OF ROOF BEAM
TOP OF CAST STONE
16'-0"
BOTTOM OF GUTTER
10'-8"
TOP OF CUT STONE
9'-0"
TOP OF CUT STONE
3'-0"
TOP OF SLAB
0'-0"
ELEV. @ STORAGE RM.
@ BUILDING 4803 (REFER TO
GRADING PLANS
NOTE: ROOF RADIUS SHOWN
SHALL BE TAKEN AT TOP OF
STRUCTURAL ROOF BEAM
LEFT SIDE ELEVATIOND2 SCALE: 18" = 1'-0"
0 2' 4' 8' 16'
CUT STONE
CAP
BATTERED COLUMN
W/ MANUFACTURED MASONRY
STANDING SEAM
METAL ROOF
RAIN CHAIN
CUT STONE CAP
PORTLAND CEMENT
PLASTER
CUT STONE
WATER TABLE
GRADE
CONCRETE SLAB
CUT STONE
CAP
BIRD
WIRE
CUT STONE
BASE
F8
REAR ELEVATIONF5 SCALE: 18" = 1'-0"
0 2' 4' 8' 16'
CUT STONE CAP
GUTTERSTANDING SEAM
METAL ROOF
RAIN CHAIN
PORTLAND CEMENT PLASTER
BATTERED COLUMN
W/ MANUFACTURED MASONRY
SIDEWALK
CUT STONE BASE
CONTROL
JOINTS
BIRD
WIRE
CUT STONE BASE
CUT STONE CAP
CUT STONE
CAP
CONVENIENCE OUTLET AND DIGITAL REPEATER
SYSTEM ACTIVATION BUTTON
-SEE ELECTRICAL FOR ADDITIONAL
INFORMATION-SEE F8/4803-300 FOR LOCATION
OF SPEAKERS FOR DIGITAL REPEATER SYSTEM
TOP OF ROOF BEAM
TOP OF CAST STONE
16'-0"
BOTTOM OF GUTTER
10'-8"
TOP OF CUT STONE
9'-0"
TOP OF CUT STONE
3'-0"
TOP OF SLAB
0'-0"
ELEV. @ STORAGE RM.
@ BUILDING 4803 (REFER TO
GRADING PLANS
F8
CROSS SECTIONF2 SCALE: 18" = 1'-0"
0 2' 4' 8' 16'
STANDING SEAM METAL ROOF
STANDING SEAM
METAL ROOF
PORTLAND CEMENT PLASTER
BATTERED COLUMN
W/ MANUFACTURED MASONRY
SIDEWALK
CUT STONE WATER TABLE
CONTROL
JOINTS
BIRD
WIRE
CUT STONE BASE
CUT STONE CAP
CUT STONE
CAP
TOP OF ROOF BEAM
TOP OF CAST STONE
16'-0"
BOTTOM OF GUTTER
10'-8"
TOP OF CUT STONE
9'-0"
TOP OF CUT STONE
3'-0"
TOP OF SLAB
0'-0"
ELEV. @ STORAGE RM.
@ BUILDING 4803 (REFER TO
GRADING PLANS
WOOD CEILING
LONGITUDINAL SECTIONF8 SCALE: 18" = 1'-0"
0 2' 4' 8' 16'
CUT STONE CAP
BATTERED COLUMN
W/ MANUFACTURED
MASONRY
STANDING SEAM
METAL ROOF
MEMBRANE ROOFING, SLOPE 14"/FT.
CUT STONE CAP
HOLLOW METAL FRAME AND DOOR
CUT STONE WATER TABLE
GRADE
R
'-9
CUT STONE BASE
OUTDOOR
SPEAKERS
F2
TOP OF ROOF BEAM
TOP OF CAST STONE
16'-0"
BOTTOM OF GUTTER
12'-2"
TOP OF CUT STONE
9'-0"
TOP OF CUT STONE
3'-0"
TOP OF SLAB
0'-0"
ELEV. @ STORAGE RM.
@ BUILDING 4803 (REFER TO
GRADING PLANS
NOTE: ROOF RADIUS SHOWN
SHALL BE TAKEN AT TOP OF
STRUCTURAL ROOF BEAM
COMMITTAL
SHELTER
F5
F8
Revisions Date
Approved: Director, Project Management Service
Approved: Director, Office of Construction Management
Drawing Title
OfDwg.
Building Number
Location
Project Title
Checked DRAWING NO.
Project No.
Date
Drawn
892CM3036
Pl ott ed : 5
/11 /20 at 9:
am
B y:
jsu nw oo Fil e:
L:\
1.0
Pr oje cts \20
-0
4 -
M ira ma r N
C Ph as e I
I\A
CA
D\ Pl an s\B id Do cs \A rch ite ctu ra l D wg s\4
3-
0-
CO
MM
IT
TA
L S
ER
VI
CE
S
HE
LT
ER
.dw g
ENGINEER OF RECORDCONSULTANTS
BID DOCUMENTS
TERRACON
1421 EDINGER AVENUE, SUITE C
TUSTIN CA 92780
(949) 383-1990
2 2 5 M i l l e r A v e n u e , M i l l V a l l e y , C A 9 4 9 4 1 T 415 383 7900 F 415 383 1433 www.rhaa.com
MAY 2020
MIRAMAR NATIONAL CEMETERY
5795 NOBEL DRIVE
SAN DIEGO, CALIFORNIA 92122
COLUMBARIUM AND CREMAINS
EXPANSION
ENGINEERED WITH LAYTON
1490 S PRICE RD, SUITE 215
CHANDLER, AZ 85286 NA NEL JHS
COMMITTAL SHELTER
ELEVATIONS & BUILDING
SECTIONS
A-102
DWG. 113 OF 127
MANUFACTURED MASONRY @ PORTLAND CEMENT WALLB2 SCALE: 3" = 1'-0"
0 1" 2" 4" 8"
2" 3" 6 12"
5 8"
PORTLAND CEMENT PLASTER
ON METAL LATH ON (2) LAYERS
15# ASPHALT FELT ON 1/2"
PLYWOOD ON 2X6 WOOD FRAMING
CASING BEAD, LAP ASPHALT
FELT OVER BEAD FLANGE
CUT STONE WATER TABLE
WITH DRIP EDGE
METAL FLASHING WITH
1/4" HEMMED DRIP
MANUFACTURED MASONRY
ON MORTAR BED ON METAL
LATH ON (2) LAYERS 15#
ASPHALT FELT ON 1/2" PLYWOOD
ON 2X6 WOOD FRAMING
-LAP ASPHALT FELT UNDER
FLASHING ABOVE
SEALANT WITH BACKER ROD
PIN ANCHOR-SIMILAR
TO B9/300
-SEALANT @ PIN
WOOD BLOCKING
1/2" PLYWOOD
-NO FINISH
STORAGE
TYPICAL BIRD SPIKE DETAIL @ LEDGEB4 SCALE: 3" = 1'-0"
SECTION
8"
5/
8"
1. PROVIDE BIRD-B-GONE INC., BIRD-X INC., OR NIXALITE OF AMERICA
INC. PRODUCTS INSTALLED BY MANUFACTURER'S PUBLISHED
INC. RECOMMENDATIONS.
2. INSTALL USING NON-SILICONE CONSTRUCTION ADHESIVE ON CLEAN
SUBSTRATE.
3. INSTALL AT ALL LEDGES AND PROJECTIONS, PIPES, CREVICES,
WHERE SHOWN, AND AS REQUIRED, TO PREVENT NESTING AND
EXTENDED ROOSTING. GENERALLY ONLY IN PROTECTED LOCATIONS,
BENEATH OVERHANGING ROOFS.
STAINLESS STEEL ROD
UV STABILIZED
POLYCARBONATE
BOTTOM VIEW
WALL SECTIONB5 SCALE: 3/4" = 1'-0"
TOP OF CUT STONE
3'-0"
TOP OF SLAB
0'-0"
B
METAL THRU WALL FLASHING
W/ 1/4" HEMMED DRIP EACH SIDE
PIN ANCHOR TYP.
SEE B9/300 SEALANT
AT PIN
CUT STONE CAP
W/ FORMED DRIP
2'-10"
2" 2'-4" 2"
MANUFACTURED
MASONRY ON CMU
CMU W/ #4 REBAR @
16" O.C., E.W.E.F., GROUT SOLID
SEALANT W/ BACKER ROD
CUT STONE BASE
LANDSCAPE TREATMENT-
SEE LANDSCAPE DRAWINGS
FINISH GRADE
-SEE CIVIL DRAWINGS
CONCRETE SLAB
SEE CIVIL DWGS.
FILL UNDER SLAB
-SEE STRUCTURAL
PAD ELEV.-
SEE CIVIL
3" 11" 11" 3"
4" M
IN
VA
R
IE
S
4" 1'-0" 1'-0" 4"
SEALANT W/
BACKER ROD
PIN ANCHOR
SIM TO 5/S502
SEALANT @ PIN
CONCRETE FOOTING
SEE STRUCTURAL
0 1" 2" 4" 8" 0 4" 8" 16" 32" 0 1" 2" 4" 8"
METAL ROOF FASCIA DETAIL AT GUTTERB8 SCALE: 3/4" = 1'-0"
1.
GENERAL NOTES:
ALL FRAMING LUMBER SHALL COMPLY WITH STRUCTURAL
TIMBER NOTES.
2. SEE STRUCTURAL DRAWINGS FOR CONCRETE SLAB AND
FOOTINGS
3. SLOPE ALL SIDEWALKS AND GRADING AWAY FROM BUILDING
MINIMUM 1/4" PER FOOT UNLESS NOTED OTHERWISE BY
CIVIL OR LANDSCAPE DRAWINGS.
4. PROVIDE WOOD BLOCKING FOR ALL WALL AND CEILING
MOUNTED FIXTURES, ACCESSORIES, ETC.
STANDING SEAM METAL ROOF
30# ASPHALT FELT ON 5/8" PLYWOOD
ALUMINUM Z-RECEIVER
SET IN SEALANT
GUTTER STRAP
ALUMINUM GUTTER
W/ 1/16"/12" SLOPE
2X WOOD BLOCKING
WOOD CEILING ON FURRING
TUBE STEEL AT CURVED
ROOF-SEE STRUCTURAL
CUT BETWEEN HORIZONTAL
2X6 WOOD FRAMING
ALUMINUM FASCIA ON
BOTTOM AND INTERIOR
FACES OF WOOD FRAMING
ALUMINUM FLASHING WITH
DRIP EDGE
ALUMINUM GUTTER
SUPPORT
ALUMINUM
GUTTER DRAIN
ALUMINUM RAIN
CHAIN TO SPLASHBLOCK
5 7/8"
6"
NOTE: SOFFIT, GUTTER,
ACCESSORIES AND
FLASHINGS TO MATCH
FINISH OF ROOF
C
WALL SECTIONF1 SCALE: 3/4" = 1'-0"
0 4" 8" 16" 32"
F4
TOP OF ROOF BEAM
13'-3"
ELEV. @ STORAGE RM.
@ BUILDING 4803 (REFER TO
GRADING PLANS
BOTTOM OF
GUTTER
12'-2"
T/SLAB
0'-0"
B2
FLASHING AT LOW POINT-
SEE DETAIL D4/4803-500
TOP OF CUT STONE
16'-0"
STANDING SEAM
METAL ROOF ON
WEATHER BARRIER
ON PLYWOOD
CUT STONE CAP SIMILAR
TO D6/4803-502
2'-8"
2'-8" 2" 1'-2" 1'-2" 2"
6"
6"
4" 8"
4" 6"
1'-0" 1'-0" 7"
2'-4" 1'-2" 1"1"
4"
FLASHING AT HIGH POINT
-SEE D2/4803-500
WOOD CEILING
ON FURRING
STEEL BEAM-
SEE STRUCTURAL
PAINT EXPOSED STEEL P-3
GUTTER
MANUFACTURED MASONRY
ON METAL LATH ON (2) LAYERS
OF WEATHER BARRIER ON
PLYWOOD
STEEL COLUMN
-SEE STRUCTURAL
SPLASH BLOCK SEE
DTL. D8/4803-500 (TYP.)
COBBLE-SEE
LANDSCAPING
FINISH
GRADE-
SEE CIVIL
WEEP SCREED
CUT STONE
CONC. SLAB
SEE STRUCTURAL
FILL UNDER SLAB
SEE STRUCTURAL
PAD ELEVATION
SEE CIVIL
CONC. FOOTING
SEE STRUCTURAL
C
WALL SECTIONF5 SCALE: 3/4" = 1'-0"
0 4" 8" 16" 32"
TOP OF ROOF BEAM
13'-3"
BOTTOM OF
GUTTER
12'-2"
BOTTOM OF
T/SLAB
0'-0"
FLASHING AT LOW POINT-
SEE DETAIL D4/4803-500
TOP OF CUT STONE
16'-0"
STANDING SEAM METAL
ROOF ON WEATHER BARRIER
ON PLYWOOD
CUT STONE CAP SIMILAR
TO D6/4803-502
2'-8"
2'-8" 2" 1'-2" 1'-2" 2"
6"
6"
4"
2'-4" 1'-2" 1"1"
4"
FLASHING AT HIGH POINT
-SEE D2/4803-500
WOOD CEILING
ON FURRING
STEEL BEAM-
SEE STRUCTURAL
PAINT EXPOSED STEEL P-3GUTTER AND
RAINCHAIN
MANUFACTURED MASONRY
BEYOND
CUT STONE
CONC. SLAB
SEE STRUCTURAL
ELEV. @ STORAGE RM.
@ BUILDING 4803 (REFER TO
GRADING PLANS
B8
TYP. GUTTER DTL-SIM.
W/ METAL SOFFIT
FLASHING AT SIDE POINT-
SEE DETAIL D6/4803-500
WHERE STEEL BEAM PENETRATES
MANUFACTURED MASONRY, PROVIDE
2" JOINT ALL AROUND STEEL, AND
FILL JOINT WITH BACKER ROD AND
SEALANT TO MATCH MORTAR COLOR
FILL UNDER SLAB-
SEE STRUCTURAL
PAD ELEV.
-SEE CIVIL
6"
B
4'-0"
6"
B2
B8
4803 CUT STONE
B4
4803 BIRD SPIKE
8" M
IN
TOP OF CUT STONE
16'-0"
FLASHING AT HIGH POINT-
SEE DETAIL D2/4803-500
FLASHING AT SIDE POINT-
SEE DETAIL D6/4803-500
FLASHING AT LOW POINT-
SEE DETAIL D4/4803-500
2" 1'-2" 1'-2" 2" CUT STONE CAP SIMILAR
TO D6/4803-502
2'-8"
MANUFACTURED MASONRY
BEYOND
STANDING SEAM METAL
ROOF ON WEATHER BARRIER
ON PLYWOOD
GUTTER AND
RAINCHAIN
MEMBRANE ROOFING ON
COVER BOARD ON TAPERED
INSULATION ON PLYWOOD
CUT STONE CAP W/
BIRD SPIKE BEYOND
PORTLAND CEMENT
PLASTER ON METAL LATH
ON (2) LAYERS OF WEATHER
BARRIER ON PLYWOOD
WOOD HEADER-
SEE STRUCTURAL
TOP OF PAVING-
SEE CIVIL
HOLLOW METAL FRAME
AND DOOR W/ VENT
CUT STONE WATER
TABLE BEYOND
MANUFACTURED
MASONRY BEYOND
CUT STONE BASE
TYPICAL SEALANT WITH
COMPRESSIBLE FILLER
FINISH GRADE
SEE CIVIL
BOTTOM OF GUTTER
10'-8"
TOP OF CUT STONE
9'-0"
BOTTOM OF DECK
7'-7 12"
C.J.
7'-4"
CONTROL JOINT
4'-4"
TOP OF CUT STONE
3'-0"
TOP OF SLAB
0'-0"
STEEL BEAM-
SEE STRUCTURAL
PAINT EXPOSED STEEL P-3
BIRD SPIKE
WOOD CEILING
ON FURRING
CUT STONE CAP
FIRE BLOCKING
PORTLAND CEMENT
PLASTER ON METAL LATH
ON (2) LAYERS OF WEATHER
BARRIER ON PLYWOOD
CONTROL
JOINT
CONTROL
JOINT
CUT STONE
WATER TABLE
MANUFACTURED MASONRY ON
METAL LATH ON (2) LAYERS
WEATHER BARRIER ON PLYWOOD
WEEP SCREED
CUT STONE BASE
CONCRETE SLAB
-SEE STRUCTURAL
4"
ELEV. @ STORAGE RM.
@ BUILDING 4803 (REFER TO
GRADING PLANS
ELEV. @ STORAGE RM.
@ BUILDING 4803 (REFER TO
GRADING PLANS
FILL UNDER SLAB-
SEE STRUCTURAL
PAD ELEV.
-SEE CIVIL
1'-8"
WALL SECTIONF8 SCALE: 3/4" = 1'-0"
0 4" 8" 16" 32"
STORAGE
PLYWOOD SHEATHING ALL
INTERIOR WALLS, NO FINISH
VAPOR BARRIER & FILL
UNDER SLAB-
SEE STRUCTURAL
LIGHT FIXTURE
ON WOOD BLOCKING
FLASHING
DIGITAL REPEATER SYSTEM,
SEE ELECTRICAL.
POSITION SPEAKERS TO
OPTIMIZE SOUND REFLECTION
OFF WOOD CEILING
A
B8
RAINCHAIN
B9 TYPICAL STONE TO STRUCT. CONNECTION
SCALE: -- = 1'-0"
1 2"
M
IN
1 2" M
AX
1 2" M
IN
STONE CAP
#4 BAR X 6" HOT DIPPED
GALVANIZED EPOXIED INTO
8" DIA. HOLES (2) PER
PIECE-TYP.-UNLESS OTHERWISE
NOTED
SPECIAL INSPECTION
REQUIRED
STRUCTURE PER
PLAN
Revisions Date
Approved: Director, Project Management Service
Approved: Director, Office of Construction Management
Drawing Title
OfDwg.
Building Number
Location
Project Title
Checked DRAWING NO.
Project No.
Date
Drawn
892CM3036
Pl ott ed : 5
/11 /20 at
:02 am
B y:
jsu nw oo Fil e:
L:\
1.0
Pr oje cts \20
-0
4 -
M ira ma r N
C Ph as e I
I\A
CA
D\ Pl an s\B id Do cs \A rch ite ctu ra l D wg s\4
3-
0-
CO
MM
IT
TA
L S
ER
VI
CE
S
HE
LT
ER
R
EV
.dw g
ENGINEER OF RECORDCONSULTANTS
BID DOCUMENTS
TERRACON
1421 EDINGER AVENUE, SUITE C
TUSTIN CA 92780
(949) 383-1990
2 2 5 M i l l e r A v e n u e , M i l l V a l l e y , C A 9 4 9 4 1 T 415 383 7900 F 415 383 1433 www.rhaa.com
MAY 2020
MIRAMAR NATIONAL CEMETERY
5795 NOBEL DRIVE
SAN DIEGO, CALIFORNIA 92122
COLUMBARIUM AND CREMAINS
EXPANSION
ENGINEERED WITH LAYTON
1490 S PRICE RD, SUITE 215
CHANDLER, AZ 85286 NA NEL JHS
COMMITTAL SHELTER
ELEVATIONS & BUILDING
SECTIONS
A-103
DWG. 114 OF 127
COL
0 1" 2" 4" 8"
MANUFACTURED MASONRY DETAIL @ BATTERED WALLB2 SCALE: 3" = 1'-0"
±3"
SEE WALL SECTION FOR
TOP OF WALL DIMENSION
MANUFACTURED MASONRY
MORTAR BED
METAL LATH
(2) LAYERS OF #15
ASPHALT FELT
2" PLYWOOD ON 2X6
WOOD STUDS
NOTE:
INSTALL MANUFACTURED MASONRY
PIECES SUCH THAT FACES ARE
PLUMB BY APPLYING A GREATER
AMOUNT OF MORTAR AT THE TOP OF
STONE THAN AT BOTTOM. ENSURE
BACKS COMPLETELY BUTTERED WITH
A MORTAR BOND COAT OF MINIMUM
THICKNESS PER MFR. INSTRUCTIONS
3" ±
SEE WALL SECTION
FOR BOTTOM OF WALL
DIMENSION
ANGLE VARIES PER TOP
AND BOTTOM DIMENSIONS
COL
0 1" 2" 4" 8"
CUT STONE BASE DETAIL @ GRADEB4 SCALE: 3" = 1'-0"
9" ±3" 1"
4"
4" 4"
MANUFACTURED MASONRY
ON MORTAR BED ON METAL
LATH ON (2) LAYERS 15#
ASPHALT FELT ON 12" PLYWOOD
ON 2X6 WOOD FRAMING
WEEP SCREED
CUT STONE W/ 12" CHAMFER
AND 2% SLOPED TOP ON
MORTAR BED
PIN ANCHOR SIM. TO B9/300
SEALANT @ PIN
FLASHING ON SEALANT BED
W/ WEEPS @ 4'-0" O.C. &
EXTEND FLASHING UP AND
BEHIND WEEP SCREED
COBBLE-
SEE LANDSCAPE
COLUMN BEYOND
-SEE STRUCTURAL
CONCRETE SLAB
-SEE STRUCTURAL
COL
0 1" 2" 4" 8"
CUT STONE BASE DETAIL @ SIDEWALKB6 SCALE: 3" = 1'-0"
9" ±3" 1"
4"
4" 4"
MANUFACTURED MASONRY ON MORTAR BED ON
METAL LATH ON (2) LAYERS 15# ASPHALT FELT ON 12"
PLYWOOD ON 2X6 WOOD FRAMING
WEEP SCREED
CUT STONE W/ 12" CHAMFER
AND 2% SLOPED TOP ON
MORTAR BED
PIN ANCHOR SIM. TO B9/300
COMPRESSIBLE JOINT FILLER
W/ SEALANT
FLASHING ON SEALANT BED
W/ WEEPS @ 4'-0" O.C. &
EXTEND FLASHING UP AND
BEHIND WEEP SCREED
COLUMN BEYOND
-SEE STRUCTURAL
CONCRETE SLAB
-SEE STRUCTURAL
SEALANT @ PIN
PAVING-SEE STRUCTURAL
0 1" 2"
4"
8"
CUT STONE CAP DETAIL AT PORTLAND CEMENT PLASTER
B8 SCALE: 3" = 1'-0"
2 12" 6 12" 1" 2"
1'-0"
EQ. EQ.
8"
8"
CUT STONE
METAL FLASHING,
PAINT TO MATCH
CUT STONE
SEALANT @ PIN
TYPICAL PIN ANCHOR
SEE B9/300
WRAP ASPHALT FELT
OVER MEMBRANE
ROOFING
MEMBRANE ROOFING
WRAP OVER TOP
OF STUD
METAL FLASHING W/
4" HEMMED DRIP
PORTLAND CEMENT PLASTER
ON METAL LATH ON (2) LAYERS
15# ASPHALT FELT ON 12"
PLYWOOD
2" PLYWOOD ON WOOD STUD
FRAMING
0 1" 2" 4" 8"
CUT STONE SCUPPER PLAN DETAILD2
SCALE: 3" = 1'-0"
1 2"
3"
1" 4"
8" 2" 6"
8"
4" 1"
MEMBRANE ROOFING
WRAP AROUND CUT STONE
2" PLYWOOD ON
2X6 WOOD FRAMING
CENTER LINE
OF CUT STONE
2" 2 5 8" 6"
PIN ANCHOR-TYPICAL
BY CUT STONE MFR.
-PIN AND SEALANT TO
CUT STONE BELOW
SEALANT
CUT STONE
SEALANT
& KERF
MANUFACTURED MASONRY
ON MORTAR BED ON METAL
LATH ON (2) LAYERS 15#
ASPHALT FELT ON 12" PLYWOOD
-WRAP ASPHALT FELT AROUND
WOOD
COL
6' -0
6"
8"
3"
2 5 8" 1'-0"
1'-5 14"
8" 3"
8"
D2
D6
0 1" 2" 4" 8"
CUT STONE SCUPPER ELEVATION DETAILD4
SCALE: 3" = 1'-0"
CUT STONE HEAD
PIN ANCHOR-TYP.
BY CUT STONE MFR.
CUT STONE SPOUT
SEALANT W/
BACKER ROD-TYP.
COL
0 1" 2" 4" 8"
CUT STONE SCUPPER DETAIL (SIM. @ PLASTER WALL)D6
SCALE: 3" = 1'-0"
4" 6"
8"
8" 3/
8"
3"
8" 7 5 8"
3"
1" 3" ± 6 12"
MANUFACTURED MASONRY
ON MORTAR BED ON METAL
LATH ON (2) LAYERS 15#
ASPHALT FELT ON 12" PLYWOOD
-WRAP ASPHALT FELT AROUND
WOOD
WEEP SCREED
SEALANT W/
BACKER ROD
DRIP EDGE
KERF &
SEALANT
1"
MEMBRANE ROOFING
WRAP 15# ASPHALT FELT
AROUND WOOD FRAMING
-FASTEN AT PLYWOOD SIDES ONLY
SEALANT
CUT STONE HEAD
ANCHOR TO SUBRAME
SEALANT AT
END OF
MEMBRANE
ROOFING
SEALANT W/
BACKER ROD
DRIP EDGE
METAL FLASHING OVER
15# ASPHALT FELT
OVER WOOD FRAMING
MEMBRANE ROOFING
ON COVER BD. ON
TAPERED INSUL.
-MIN. 3" R-15
SEALANT & TYPICAL
PIN ANCHOR-SEE B9/300
8" PLYWOOD
WOOD FRAMING-
SEE STRUCTURAL
0 1" 2" 4" 8"
RAIN CHAIN DETAIL AT SPLASHBLOCKD8
SCALE: 3" = 1'-0"
ALIGN W/ CENTER OF
GUTTER LEADER ABOVE
-RAIN CHAIN SHALL BE
VERTICALLY PLUMB
CL
FACE OF BUILDING
ALUMINUM RAINCHAIN
COBBLE,
SEE LANDSCAPE
ALUMINUM EYE-HOOK
CAST INTO CONCRETE
W/ 2 12" EMBED
CONCRETE
SPLASHBLOCK
(2) #5 REBAR
EACH WAY
EXTENT OF COBBLE AT SIDEWALK,
EARTH UNDER SIDEWALK
NOTE: CONCRETE SPLASHBLOCK MAY BE SITE CAST CONCRETE,
BUT SHALL BE ISOLATED FROM BONDING WITH ADJACENT
MATERIALS, AND SHALL BE ABLE TO BE REPOSITIONED TO
ENSURE RAINCHAIN IS VERTICALLY PLUMB.
4" 8"
8"
EQ
EQ
4"
1 12" TYP.
8"
3"
0 1" 2" 4" 8"
STANDING SEAM METAL ROOF DETAIL @ COLUMN (HIGH)F2
SCALE: 3" = 1'-0"
MANUFACTURED MASONRY
ON MORTAR BED ON METAL
LATH ON (2) LAYERS 15#
ASPHALT FELT ON 12" PLYWOOD
ON 2X6 WOOD FRAMING
WEEP SCREED
FLASHING
STANDING SEAM
METAL ROOF
ALUM Z-RECEIVER
SET IN SEALANT
30# ASPHALT FELT
ON 5 8" PLYWOOD
T&G WOOD CEILING
ON WOOD FRAMING
COL
2" 3" ± 9"
1 2"
0 1" 2" 4" 8"
STANDING SEAM METAL ROOF DETAIL @ COLUMN (LOW)F4 SCALE: 3" = 1'-0"
T&G WOOD CEILING
ON WOOD FRAMING
COL
SEE WALL SECTIONS
FOR DIMENSIONS
FROM CENTER LINE AT
TOP & BOTTOM OF
INCLINED WALL
3" ±
MANUFACTURED MASONRY ON MORTAR BED ON METAL
LATH ON (2) LAYERS 15# ASPHALT FELT ON 12" PLYWOOD
ON 2X6 WOOD FRAMING
WEEP SCREED
FLASHING
ALUM Z CLIP AT
VERTICAL LEG
& UNDER Z
4" TURN-UP
STANDING SEAM METAL
ROOF ON 30# ASPHALT FELT
ON 5 8" PLYWOOD
COL
9" 3" ± SEE ROOF PLAN
1 4"
0 1" 2" 4" 8"
STANDING SEAM METAL ROOF DETAIL @ RAKE WALLF6 SCALE: 3" = 1'-0"
T&G WOOD CEILING
ON WOOD FRAMING
MANUFACTURED MASONRY
ON MORTAR BED ON METAL
LATH ON (2) LAYERS 15#
ASPHALT FELT ON 12" PLYWOOD
ON 2X6 WOOD FRAMING
WEEP SCREED
FLASHING & J-CLOSURE
MECHANICALLY FASTENED
SEAM
STANDING SEAM METAL
ROOF ON 30# ASPHALT FELT
ON 5 8" PLYWOOD
2X3 WOOD BLOCKING
SEALANT
0 1" 2" 4" 8"
HOLLOW METAL DOOR FRAME-JAMBF8 SCALE: 3" = 1'-0"
MANUFACTURED MASONRY
ON MORTAR BED ON METAL
LATH ON (2) LAYERS 15#
ASPHALT FELT ON 12" PLYWOOD
ON 2X6 WOOD FRAMING
SEALANT W/ BACKER ROD
HOLLOW METAL FRAME
SCHEDULED DOOR
2" EXPOSED PLYWOOD
SEALANT ALL AROUND
±6 5 8"
Revisions Date
Approved: Director, Project Management Service
Approved: Director, Office of Construction Management
Drawing Title
OfDwg.
Building Number
Location
Project Title
Checked DRAWING NO.
Project No.
Date
Drawn
892CM3036
Pl ott ed : 5
/11 /20 at
:18 am
B y:
jsu nw oo Fil e:
L:\
1.0
Pr oje cts \20
-0
4 -
M ira ma r N
C Ph as e I
I\A
CA
D\ Pl an s\B id Do cs \A rch ite ctu ra l D wg s\4
3-
1-
CO
MM
IT
TA
L S
ER
VI
CE
S
HE
LT
ER
.dw g
ENGINEER OF RECORDCONSULTANTS
BID DOCUMENTS
TERRACON
1421 EDINGER AVENUE, SUITE C
TUSTIN CA 92780
(949) 383-1990
2 2 5 M i l l e r A v e n u e , M i l l V a l l e y , C A 9 4 9 4 1 T 415 383 7900 F 415 383 1433 www.rhaa.com
MAY 2020
MIRAMAR NATIONAL CEMETERY
5795 NOBEL DRIVE
SAN DIEGO, CALIFORNIA 92122
COLUMBARIUM AND CREMAINS
EXPANSION
ENGINEERED WITH LAYTON
1490 S PRICE RD, SUITE 215
CHANDLER, AZ 85286 NA NEL JHS
A-501
COMMITTAL SHELTER
DETAILS
DWG. 115 OF 127
SB
SBSB
SB SB
COMMITTAL
SHELTER
36x32 UNDER ROOF
NOTES: SCALE:1/8"=1'-0"
REFERENCE
NORTH
H S S8x
8x 1/
2H S S8x8x1/2
H S S8x
8x 1/
H S S8x
8x 1/
-1.50'F8.0
-1.50'F8.0
-1.50'F8.0
S S
4. ALL FOOTINGS SHALL BE CENTERED UNDER WALLS OR COLUMNS UNLESS NOTED OTHERWISE.
5. INDICATES STEPPED FOOTINGS. SEE DETAIL 3/S502
6. TYPICAL STUD WALLS SHALL BE AS FOLLOW, UNLESS NOTED OTHERWISE:
4" NOMINAL WALL
INTERIOR NON-BEARING STUD WALLS................2x4 @ 16"o.c.
BEARING AND SHEAR WALLS................................4x4 @ 16"o.c. D.F.#1
6" NOMINAL WALL
EXTERIOR STUD WALLS........................................2x6 @ 16"o.c.
BEARING AND SHEAR WALLS...............................2x6 @ 16"o.c.
7. INDICATES WALL ABOVE.
8. INDICATES SIDE OF SHEAR WALL PLYWOOD IS TO BE NAILED.
9. INDICATES WOOD SHEAR WALL REFERENCE ELEVATION.
INDICATES MINIMUM LENGTH OF SHEAR WALL REQUIRED.
13. MINIMUM PLYWOOD SHEATHING WIDTH OF SHEAR WALL TO BE 48".
14. SEE ARCHITECTURAL DRAWINGS FOR ELEVATION TOP OF CONCRETE SLAB, DEPRESSIONS, SLOPES, OPENINGS, CURBS, DRAINS, TRENCHES, SLAB EDGE LOCATIONS, ALL OVERALL DIMENSIONS AND
LOCATION OF OPENINGS NOT INDICATED ON STRUCTURAL DRAWINGS.
15. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND LOCATING ALL OPENINGS THROUGH
THE SLAB INCLUDING BUT NOT LIMITED TO ELECTRICAL, MECHANICAL, PLUMBING, SPRINKLER AND
TELEPHONE. SUBMIT TO THE STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO SUBMITTAL OF
REINFORCING STEEL SHOP DRAWINGS.
0'-0"
C. 4" OF AGGREGATE BASE BELOW THE VAPOR BARRIER
A. 5" CONCRETE SLAB WITH #4@16"o.c. CENTERED EACH WAY. U.N.O.
2. TYPICAL SLAB ON GRADE CONSTRUCTION SHALL BE AS FOLLOWS: (REF. GEOTECHNICAL REPORT)
1. ELEVATION TOP OF CONCRETE SLAB SHALL BE DATUM +XX.XX'= +0.00' UNLESS NOTED
D. COMPACTED ENGINEERING FILL BELOW THE AGGREGATE BASE
B. 10 MIL CLASS A VAPOR BARRIER BELOW SLAB
E. SUBGRADE PER SOILS REPORT.
10. INDICATES GRADE BEAM MARK. 18"WIDEx18"DEEP w/(4)#6 T&B.
OTHERWISE THUS (+0.00')
INDICATES TOP OF FOOTING ELEVATION BELOW DATUM. TOP OF CONTINUOUS WALL
FOOTING SHALL BE AT 0.00' FROM LOWEST ADJACENT TOP OF CONCRETE
3. INDICATES FOOTING TYPE. SEE DETAIL X/SX FOR SIZE AND REINFORCING.
SLAB ON GRADE UNLESS NOTED OTHERWISE.
0.00'F1
11. INDICATES WOOD POST.
6x6
12. INDICATES STEEL COLUMN.HSSx
16. FRAME OPENINGS FOR DOOR AND WINDOWS PER DETAIL x/Sx UNLESS NOTED OTHERWISE.
SHALL BE 8d @ 6"o.c. AT ALL EDGES AND 8d @ 12"o.c. AT ALL INTERMEDIATE SUPPORTS MINIMUM.
17. SHEATH ALL EXTERIOR WALLS WITH 1/2" CDX PLYWOOD, UNLESS NOTED OTHERWISE. PLYWOOD NAILING
TYPICAL SOUND WALL (SEE DETAIL x/Sx)
MINIMUM.................................................................4x4 @ 8"o.c. STAGGERED
18. ALL SILL PLATE ANCHORS SHALL BE EMBEDDED 10" MINIMUM INTO CONCRETE FOOTING
...................................2x8 @ 16"o.c. D.F.#1
CORRIDOR WALL....................................................2x6 @ 16"o.c.
19. INDICATES CONCRETE 3" MAX. DEPRESSED SLAB PER ARCHITECTURAL DRAWINGS.
SEE DETAIL 8/S502.
(ALT: 362S137-33 @16"o.c.)
INDICATES CONTINUOUS FOOTING DESIGNATION
INDICATES SPREAD FOOTING DESIGNATION
NOTES:
8'-0" x 8'-0" 24" (8)#5 (8)#5 (8)#5 (8)#5
6x6 6x6
4x4
4x
4x
4x4
0.00'CF1.5
1'-6" x CONT. 24" (2)#5 #5@12 (2)#5 #5@12
20. INDICATES HSSx CANTILEVER.
0.00'CF1.5 0.00'CF1.5
21. INDICATES ORIENTATION OF SLAB FRAMING SLOPE (0.5%) MINIMUM 1.5" COVER
STEEL SHALL REMAIN.
NOTES:
REFERENCE
NORTH
SCALE:1/8"=1'-0"
C U
R V
E D
S L O
P E
C U
R V
E D
S L O
P E
H S S8x
8x 5/
(B
H S S8x8x5/8
(B)
S506
H S
S x x /8
H S
S x x /8
H S
S x x /8
H S
S x x /8
HSS12x6x3/8
2x6
@24"o.c.
2x6
@24"o.c.
2x6
@24"o.c.
2x6
@24"o.c.
2x6
@24"o.c.
2x6
@24"o.c. (LOW)
6x6
HEADER
1. FOR GENERAL NOTES AND TYPICAL DETAILS, SEE S1.X SERIES SHEETS.
2. ELEVATION TOP OF SHEATHING SHALL BE COORDINATED WITH ARCHITECTURAL,
UNLESS NOTED OTHERWISE.
3. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND LOCATING ALL OPENING THROUGH
THE ROOF INCLUDING BUT NOT LIMITED TO ELECTRICAL, MECHANICAL, PLUMBING, SPRINKLER AND
TELEPHONE. SUBMITTAL TO THE STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO SUBMITTAL OF
REINFORCING STEEL SHOW DRAWINGS.
4. ALL NAILS SHALL BE COMMON NAILS.
1/2" CDX PLYWOOD STRUCT-I
w/ 10d COMMON NAIL @6:12
SPAN RATING 32/16
H S S8x8x5/8
(B) H S S8x
8x 5/
(B
S504
BEAM TO BE
BENT/CURVED TO
MATCH ARCHITECTURAL
ROOF LAYOUT
S506
TYP.
S506
TYP.
HSS6x4x HSS6x4x
E N
D x
E N
D x
S506
S506
S506
6x
(B
6x (B)
S506
S504
S506
S506
S506
TYP.
TYP.
5. ROOF SHEATHING TO BE 1/2" STRUCT-I PLYWOOD w/ 10d NAILS @4:12 BLOCKED. PANEL I.D. 32/16.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING THE STRUCTURE.
S504
Revisions Date
Approved: Director, Project Management Service
Approved: Director, Office of Construction Management
Drawing Title
OfDwg.
Building Number
Location
Project Title
Checked
DRAWING NO.
Project No.
Date
Drawn
892CM3036
ENGINEER OF RECORDCONSULTANTS
TERRACON
1421 EDINGER AVENUE, SUITE C
TUSTIN CA 92780
(949) 383-1990 2 2 5 M i l l e r A v e n u e , M i l l V a l l e y , C A 9 4 9 4 1
T 415 383 7900 F 415 383 1433 www.rhaa.com
MIRAMAR NATIONAL CEMETERY
5795 NOBEL DRIVE
SAN DIEGO, CALIFORNIA 92122
COLUMBARIUM AND CREMAINS
EXPANSION
ENGINEERED WITH LAYTON
1490 S PRICE RD, SUITE 215
CHANDLER, AZ 85286 JS RD
BID DOCUMENTS
NOT FOR CONSTRUCTION
MARCH 2020
S-101 1 9
COMMITTAL SERVICE SHELTER
FOUNDATION AND ROOF PLAN
DWG. 116 OF 127
1. APPLICABLE BUILDING CODE:
PERFORM CONSTRUCTION AND WORKMANSHIP COMPLYING WITH CONTRACT
DOCUMENTS AND 2016 CALIFORNIA BUILDING CODE (CBC).
3. GOVERNING CODE AUTHORITY:
CITY OF SAN DIEGO DEPARTMENT OF BUILDING AND SAFETY.
4. CONTRACT DOCUMENTS:
PERFORM STRUCTURAL RELATED WORK, INCLUDING THE DEVELOPMENT
OF SHOP DRAWINGS, WITH THE CONSIDERATION OF ALL CONTRACT
DOCUMENTS. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS,
ROOF AND FLOOR ELEVATIONS, EDGE OF SLABS, OPENINGS, DEPRESSIONS,
SLOPES, CURBS, DRAINS, AND TRENCHES NOT SHOWN IN STRUCTURAL
DRAWINGS. ANY DISCREPANCIES BETWEEN ARCHITECTURAL AND
STRUCTURAL DRAWINGS SHALL BE RESOLVED WITH THE ARCHITECT
(STRUCTURAL ENGINEER) PRIOR TO PROCEEDING WITH WORK.
5. DESIGN INTENT:
STRUCTURAL DRAWINGS, AS PART OF THE CONTRACT DOCUMENTS,
INDICATE INFORMATION SUFFICIENT TO CONVEY DESIGN INTENT.
CONTRACTOR SHALL REVIEW CONTRACT DOCUMENTS AND PROMPTLY
NOTIFY ARCHITECT (STRUCTURAL ENGINEER) OF ANY DISCREPANCIES
OR QUESTIONS PRIOR TO PROCEEDING WITH WORK.
6. TYPICAL DETAILS AND SCHEDULES:
DETAILS AND SCHEDULES INDICATED AS "TYPICAL" ARE APPLICABLE
THROUGHOUT THE PROJECT AND MAY NOT BE SPECIFICALLY
REFERENCED IN STRUCTURAL DRAWINGS. CONTRACTOR SHALL
DETERMINE WHERE TYPICAL DETAILS AND SCHEDULES APPLY PRIOR TO
PROCEEDING WITH WORK. SHOULD CONDITIONS EXIST THAT ARE NOT
SPECIFICALLY DETAILED AND NO TYPICAL DETAIL APPLIES,
PROMPTLY NOTIFY ARCHITECT (STRUCTURAL ENGINEER).
8. SITE CONDITIONS:
CONTRACTOR SHALL VERIFY SITE CONDITIONS INCLUDING DIMENSIONS
AND ELEVATIONS. PROMPTLY NOTIFY ARCHITECT (STRUCTURAL
ENGINEER) OF ANY DISCREPANCIES OR CONFLICT WITH CONTRACT
DOCUMENTS PRIOR TO PROCEEDING WITH WORK.
9. MEANS AND METHODS OF CONSTRUCTION:
CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE AND DO
NOT INDICATE METHOD OF CONSTRUCTION. PERFORM CONSTRUCTION
MEANS, METHODS, SEQUENCES, TECHNIQUES AND PROCEDURES
COMPLYING WITH NATIONAL, STATE, AND LOCAL SAFETY ORDINANCES.
CONTRACTOR SHALL PROVIDE SHORING AND BRACING TO ENSURE
STABILITY OF STRUCTURE AND GENERAL SAFETY DURING
CONSTRUCTION.
10. SITE OBSERVATIONS:
SITE OBSERVATION VISITS BY FIELD REPRESENTATIVES OF
ARCHITECT (STRUCTURAL ENGINEER) DO NOT INCLUDE CONTINUOUS
INSPECTION SERVICES AND/OR APPROVAL FOR METHOD OF
CONSTRUCTION. OBSERVATIONS BY ARCHITECT (STRUCTURAL
ENGINEER) ARE PERFORMED TO DETERMINE IF CONTRACTOR
UNDERSTANDS DESIGN INTENT OF CONTRACT DOCUMENTS.
OBSERVATIONS DO NOT GUARANTEE CONTRACTOR'S PERFORMANCE AND
SHALL NOT BE CONSIDERED SUPERVISION OF CONSTRUCTION.
11. MODIFICATIONS AND SUBSTITUTIONS:
MATERIALS AND PRODUCTS OTHER THAN THOSE SPECIFIED MAY BE
CONSIDERED FOR USE PROVIDED A WRITTEN REQUEST IS SUBMITTED
TO OWNER, ARCHITECT (STRUCTURAL ENGINEER) AND GOVERNING
CODE AUTHORITY FOR APPROVAL PRIOR TO ITS USE OR INCLUSION
IN SHOP DRAWINGS. MODIFICATIONS AND SUBSTITUTIONS WILL NOT
BE ACCEPTED DURING SHOP DRAWING REVIEW.
12. SHOP DRAWING SUBMITTALS:
A. CONTRACTOR SHALL REVIEW FOR COMPLETENESS AND COMPLIANCE
WITH CONTRACT DOCUMENTS PRIOR TO SUBMITTING TO ARCHITECT
(STRUCTURAL ENGINEER).
B. SUBMIT SHOP DRAWINGS FOR REVIEW AND APPROVAL PRIOR TO
FABRICATION.
C. PROVIDE A PROFESSIONAL ENGINEER'S SIGNATURE AND SEAL IN
THE STATE WHERE THE PROJECT SITE OCCURS WHEN INDICATED.
D. REVIEW IS FOR GENERAL CONFORMANCE WITH DESIGN INTENT AND
DOES NOT CONSTITUTE AN AUTHORIZATION TO DEVIATE FROM THE
CONTRACT DOCUMENTS.
E. SHOP DRAWINGS WILL BE REJECTED FOR INCOMPLETENESS, LACK
OF COORDINATION WITH OTHER PORTIONS OF CONTRACT
DOCUMENTS, LACK OF CALCULATIONS (WHEN REQUIRED), OR
WHERE MODIFICATIONS OR SUBSTITUTIONS ARE INDICATED
WITHOUT PRIOR REVIEW AND APPROVAL.
F. MAINTAIN A COPY OF REVIEWED AND ACCEPTED SHOP DRAWINGS
AT SITE FOR DURATION OF CONSTRUCTION.
G. STRUCTURAL ENGINEER REQUIRES 10 WORKING DAYS FOLLOWING
RECEIPT OF SHOP DRAWINGS AND CALCULATIONS FOR COMPLETION
OF REVIEW. SHOP DRAWINGS WILL BE REVIEWED A MAXIMUM
H. FOR DESIGN-BUILD ITEMS, SUBMIT SHOP DRAWINGS THAT BEAR THE
SIGNATURE AND SEAL OF A REGISTERED CIVIL ENGINEER TO
ARCHITECT (STRUCTURAL ENGINEER) AND GOVERNING CODE
AUTHORITY FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION.
13. PIPE AND DUCT BRACING:
BRACE PIPES AND DUCTS COMPLYING WITH LATEST EDITION OF
"SEISMIC RESTRAINT MANUAL; GUIDELINES FOR MECHANICAL SYSTEMS" BY
THE SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL
ASSOCIATION.
14. EQUIPMENT INSTALLATION AND ANCHORAGE:
INSTALL AND ANCHOR MECHANICAL AND ELECTRICAL EQUIPMENT TO
STRUCTURE COMPLYING WITH ASCE 7 SECTION 13.4. ISOLATORS,
FASTENERS, AND ANY OTHER ELEMENT THAT ANCHORS EQUIPMENT SHALL
BE APPROVED BY ICC OR EQUIVALENT TESTING PROCEDURE.
SUSPENDED EQUIPMENT SHALL BE SECURED BY APPROVED LATERAL OR
SWAY BRACING.
15. STRUCTURAL DEFERRED SUBMITTAL ITEMS:
SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED
TO THE ARCHITECT (STRUCTURAL ENGINEER) TO BE REVIEWED FOR GENERAL
CONFORMANCE TO CONTRACT DOCUMENTS. PROVIDE A PROFESSIONAL ENGINEER'S
SIGNATURE AND SEAL IN THE STATE WHERE THE PROJECT SITE OCCURS.
BE INSTALLED UNTIL THEIR SUBMITTAL DOCUMENTS HAVE BEEN APPROVED
BY THE BUILDING OFFICIAL.
2. APPLICABLE STANDARDS:
SPECIFICATIONS, CODES, AND STANDARDS REFERENCED IN THE CONTRACT
DOCUMENTS SHALL BE OF THE LATEST APPROVED ISSUE, INCLUDING
SUPPLEMENTS, UNLESS NOTED OTHERWISE. MATERIAL SPECIFICATIONS
SHALL COMPLY WITH THE LATEST EDITION OF ASTM REFERENCED STANDARDS.
7. CONFLICTS IN STRUCTURAL DRAWINGS:
NOTES AND DETAILS SPECIFICALLY REFERENCED IN DRAWINGS SHALL
TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS.
WHERE STRUCTURAL DRAWINGS CONFLICT WITH PROJECT SPECIFICATIONS,
THE MORE STRINGENT SHALL APPLY. CONDITIONS NOT SPECIFICALLY
REFERENCED SHALL BE CONSTRUCTED AS SHOWN FOR SIMILAR CONDITIONS.
OF 2 TIMES.
CONTRACTOR SHALL SUBMIT REVIEWED SUBMITTAL DOCUMENTS TO GOVERNING
CODE AUTHORITY FOR APPROVAL. DEFERRED SUBMITTAL ITEMS SHALL NOT
1. LIVE LOADS:
ROOF = 20 PSF (REDUCIBLE)
STORAGE = 125 PSF (UNREDUCIBLE)
OFFICE = 100 PSF (REDUCIBLE)
STAIRS = 100 PSF (UNREDUCIBLE)
PARKING = 40 PSF (REDUCIBLE)
2. WIND LOADS:
ULTIMATE DESIGN WIND SPEED, Vult = 110 MPH
EXPOSURE CATEGORY = D
RISK CATEGORY = III
COMPONENT AND CLADDING WIND
INTERNAL PRESSURE COEFFICIENT, GCpi = 0.00 PER ASCE 26.11-1
ROOF ZONE 1 = 25 PSF
ROOF ZONE 2 = 51 PSF
ROOF ZONE 3 = 79 PSF
WALL ZONE 4 = 31 PSF
WALL ZONE 5 = 40 PSF
3. SEISMIC LOADS:
SPECTRAL RESPONSE ACCELELATIONS
SEISMIC IMPORTANCE FACTOR, I = 1.25
RISK CATEGORY = III
E
S = 1.061
S = 0.761
S = 0.432
S
DS
D1
S = 0.4071
SITE CLASS = D
SEISMIC DESIGN CATEGORY = D
SEISMIC FORCE RESISTING SYSTEM = ORDINARY STEEL CANTILEVER
RESPONSE MODIFICATION FACTOR, R = 1.25 (N/S)
RESPONSE MODIFICATION FACTOR, R = 1.25 (E/W)
SEISMIC RESPONSE COEFFICIENT, Cs = 0.761 (N/S) SEISMIC RESPONSE COEFFICIENT, Cs = 0.761 (E/W)
DESIGN BASE SHEAR, V = 11 KIPS (N/S)
DESIGN BASE SHEAR, V = 11 KIPS (E/W)
PRESSURES (ULTIMATE, A = 10 SF)
1. FOUNDATION DESIGN VALUES:
FOUNDATION DESIGN IS BASED ON THE FOLLOWING VALUES
BEARING CAPACITY ...........1500 PSF 1
LATERAL BEARING PRESSURE ...100 PSF/FT 1,2
COEFFICIENT OF FRICTION ....0.25
1. INDICATES VALUE MAY BE INCREASED 33% FOR SEISMIC OR WIND LOADING.
2. INDICATES VALUE MAY BE INCREASED 100% FOR POLE FOOTINGS.
2. MINIMUM FOOTING DEPTH:
FOUND FOOTINGS A MINIMUM OF 24 INCHES BELOW LOWEST ADJACENT GRADE
OR FINISH FLOOR, WHICHEVER IS LOWER.
3. FOUNDATION EXCAVATIONS:
FOUNDATION EXCAVATIONS SHALL BE OBSERVED AND APPROVED BY
BUILDING OFFICIAL PRIOR TO PLACING FILL, REINFORCING STEEL, OR
CONCRETE. WHERE REQUIRED BY THE BUILDING OFFICIAL, A GEOTECHNICAL
ENGINEER SHALL BE RETAINED BY THE OWNER TO INSPECT THE FOUNDATION
4. BACKFILLING AND COMPACTION:
PROPERLY BACKFILL ALL EXCAVATIONS. COMPACT BACKFILL TO AT LEAST
90% OF MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE CONTENT DETERMINED
5. RETAINING WALL BACKFILL:
PLACE BACKFILL BEHIND RETAINING WALLS FOLLOWING COMPLETION
AND INSPECTION OF WATERPROOFING. ADEQUATELY SHORE RETAINING
WALLS DURING BACKFILL OPERATION. UNLESS ADEQUATELY SHORED,
DO NOT PLACE BACKFILL BEHIND BUILDING STRUCTURE RETAINING
WALLS UNTIL CONCRETE AT ELEVATED FLOOR LEVELS ADJACENT TO
TO WALLS HAVE BEEN COMPLETELY POURED (IN AREA) AND HAVE
CURED FOR AT LEAST 7 DAYS.
6. RETAINING WALL DRAINAGE:
RETAINING WALL BACKFILL SHALL BE FULLY DRAINED OF WATER AND
OTHER FLUIDS BY MEANS OF SUB-DRAIN, WEEP HOLES, AND/OR OTHER
METHODS APPROVED BY THE GOVERNING CODE AUTHORITY.
7. GEOTECHNICAL ENGINEER:
IN ACCORDANCE WITH CBC TABLE 1806.2:
WHERE REQUIRED BY THE BUILDING OFFICIAL, A GEOTECHNICAL ENGINEER
SHALL BE RETAINED BY THE OWNER TO PROVIDE A GEOTECHINCAL REPORT
IN ACCORDANCE WITH CBC SECTION 1803.
EXCAVATIONS AND CERTIFY THAT THE OBSERVED SOIL CONDITIONS WILL
PROVIDE ADDEQUATE SUPPORT FOR THE PROPOSED FOUNDATIONS.
IN ACCORDANCE WITH ASTM D1557.
1. REINFORCING STEEL:
PROVIDE REINFORCING STEEL COMPLYING WITH THE APPROPRIATE
STANDARD AS FOLLOWS:
ALL REINFORCING UNLESS NOTED OTHERWISE .....ASTM A615 GRADE 60
WELDED REINFORCING .........................ASTM A706 GRADE 60
3. WELDED WIRE FABRIC:
PROVIDE WELDED WIRE FABRIC COMPLYING WITH THE APPROPRIATE
STANDARD AS FOLLOWS:
SMOOTH WELDED WIRE FABRIC .....................ASTM A185
DEFORMED WELDED WIRE FABRIC ...................ASTM A497
4. SHOP DRAWINGS:
PREPARE REINFORCING STEEL SHOP DRAWINGS COMPLYING WITH ACI 315.
SUBMIT REINFORCING STEEL SHOP DRAWINGS INDICATING REINFORCING
STEEL PLACEMENT, INCLUDING SPLICE LOCATIONS AND LENGTHS, TO
ARCHITECT (STRUCTURAL ENGINEER) FOR APPROVAL. PROMPTLY NOTIFY
ARCHITECT (STRUCTURAL ENGINEER) BEFORE DEVELOPING REINFORCING
STEEL SHOP DRAWINGS IF INSUFFICIENT CLEAR DISTANCE BETWEEN
REINFORCING STEEL OR OTHER CONGESTION IS ENCOUNTERED.
5. REINFORCING STEEL CONDITION DURING CONCRETE PLACEMENT:
REINFORCING STEEL SHALL BE FREE OF MUD, OIL AND OTHER MATERIALS
THAT MAY AFFECT CONCRETE BOND AT TIME OF CONCRETE PLACEMENT.
6. SPLICE LOCATION:
SPLICE REINFORCING STEEL WHERE INDICATED IN THE DRAWINGS.
IF SPLICE LOCATIONS CANNOT BE DETERMINED, VERIFY WITH
STRUCTURAL ENGINEER PRIOR TO DEVELOPING SHOP DRAWINGS.
7. SPLICE LENGTH - CONCRETE CONSTRUCTION:
LAP REINFORCING STEEL AT SPLICES TO LENGTHS INDICATED IN
STRUCTURAL DRAWINGS. LAP WIRE FABRIC 1.5 SPACES (12 INCHES
MINIMUM).
8. SPLICE LENGTH - MASONRY CONSTRUCTION:
LAP REINFORCING STEEL AT SPLICES A MINIMUM OF 72 BAR
DIAMETERS AND NOT LESS THAN 30 INCHES UNLESS NOTED OTHERWISE.
9. MINIMUM CLEAR DISTANCE BETWEEN PARALLEL REINFORCING:
MINIMUM CLEAR DISTANCE BETWEEN PARALLEL REINFORCING STEEL
SHALL BE THE GREATER OF 1 INCH OR 1 BAR DIAMETER. MINIMUM CLEAR
DISTANCE BETWEEN PARALLEL REINFORCING STEEL AT COLUMNS SHALL
BE THE GREATER OF 1-1/2 INCHES OR 1-1/2 BAR DIAMETERS. MINIMUM
CLEAR DISTANCE BETWEEN GROUPS OF BUNDLED BARS SHALL BE THE SAME
AS FOR SINGLE BARS EXCEPT BAR DIAMETER IS DERIVED FROM EQUIVALENT
TOTAL AREA OF BUNDLE.
10. MINIMUM CONCRETE COVER:
MAINTAIN THE FOLLOWING MINIMUM CLEAR DISTANCE BETWEEN
REINFORCING STEEL AND FACE OF CONCRETE, UNLESS NOTED
OTHERWISE:
SLABS ON GRADE ...............................CENTER OF SLAB
CONCRETE BELOW GRADE - FORMED ................2 INCHES
CONCRETE BELOW GRADE - UNFORMED ..............3 INCHES
12. CHAIRS AND SPACERS:
CHAIRS AND SPACERS FOR REINFORCING STEEL THAT REST ON
EXPOSED SURFACES SHALL BE PLASTIC OR PLASTIC COATED.
13. WALL AND COLUMN DOWELS:
PROVIDE DOWELS FOR WALLS AND COLUMNS TO MATCH SIZE AND
SPACING OF VERTICAL REINFORCING STEEL UNLESS NOTED
OTHERWISE.
14. WELDED REINFORCING:
15. REBAR BENDING:
BEND REINFORCING STEEL COLD UNLESS OTHERWISE APPROVED BY
STRUCTURAL ENGINEER. DO NOT FIELD BEND REINFORCING STEEL
IN CONCRETE UNLESS OTHERWISE SHOWN IN CONTRACT DOCUMENTS
OR APPROVED BY STRUCTURAL ENGINEER.
WALLS ABOVE GRADE - EXPOSED TO WEATHER........2 INCHES
WALLS ABOVE GRADE - NOT EXPOSED TO WEATHER....1 INCHES
COLUMNS - CLEAR TO FACE OF TIES...............1-1/2 INCHES
BEAMS - CLEAR TO FACE OF TIES.................1-1/2 INCHES
STRUCTURAL SLABS - TOP AND BOTTOM.............1 INCHES
2. REINFORCING (EXCLUDING TIES) IN CONCRETE MOMENT FRAMES, COUPLING
PROVIDE REINFORCING STEEL COMPLYING WITH ASTM A706 GRADE 60.
ASTM A615 GRADE 60 REINFORCING STEEL COMPLYING WITH ACI 318
BEAMS, AND SHEARWALL BOUNDARY ELEMENTS:
SECTION 20.2.2.5 SHALL ALSO BE PERMITTED.
WELD REINFORCING STEEL PER REQUIREMENTS OF AWS D1.4 AND
APPLICABLE BUILDING CODE. SUBMIT PROPOSED WELDING
PROCEDURE TO STRUCTURAL ENGINEER AND TO GOVERNING CODE
AUTHORITY FOR APPROVAL PRIOR TO WELDING. WELDERS SHALL
BE CERTIFIED AS REQUIRED BY GOVERNING CODE AUTHORITY.
11. CONCRETE COVER AT REVEALS:
SPECIFIED CONCRETE COVER SHALL BE MAINTAINED TO ALL
REINFORCING STEEL AT REVEALS AND INSETS. SUBMIT
SHOP DRAWINGS SHOWING CONCRETE REVEALS AND INSETS TO
ARCHITECT (STRUCTURAL ENGINEER) FOR REVIEW.
1. APPLICABLE STANDARD:
PERFORM CONCRETE WORK COMPLYING WITH ACI 301 AND ACI 304.
2. AGGREGATE:
3. PORTLAND CEMENT:
5. MINIMUM COMPRESSIVE STRENGTH:
7. CONCRETE SHRINKAGE:
CONCRETE SHRINKAGE CHARACTERISTICS SHALL COMPLY WITH ASTM C157 AND
SHALL NOT EXCEED 0.05%.
8. CONCRETE SLUMP:
CONCRETE SLUMP SHALL NOT EXCEED 4 INCHES.
9. CHLORIDES:
CONCRETE OR GROUT SHALL NOT CONTAIN CHLORIDES.
10. CONCRETE CURING:
CURE CONCRETE IN ACCORDANCE WITH ACI 301 SECTION 5.3.6 FOR A MINIMUM
OF 7 DAYS FOLLOWING PLACEMENT.
11. EMBEDDED ITEMS:
SECURELY TIE ANCHOR BOLTS, REINFORCING STEEL, INSERTS, AND OTHER
EMBEDDED ITEMS IN PLACE PRIOR TO POURING CONCRETE.
12. CONDUITS, PIPES AND SLEEVES EMBEDDED IN CONCRETE:
DO NOT EMBED CONDUITS, PIPES, OR SLEEVES IN STRUCTURAL CONCRETE,
INCLUDING CONCRETE ON METAL DECK, EXCEPT WHERE SPECIFICALLY DETAILED
OR APPROVED BY STRUCTURAL ENGINEER.
13. CONSTRUCTION JOINTS:
15. EXPOSED CORNERS:
FORM EXPOSED CORNERS WITH 3/4 INCH CHAMFER UNLESS NOTED OTHERWISE.
14. CONCRETE ABUTTING EXISTING CONCRETE:
ROUGHEN EXISTING CONCRETE SURFACE TO 1/4 INCH AMPLITUDE WHERE NEW
CONCRETE ABUTS EXISTING CONCRETE.
AGGREGATE FOR NORMAL-WEIGHT CONCRETE SHALL BE NATURAL SAND AND ROCK
COMPLYING WITH ASTM C33. AGGREGATE FOR LIGHTWEIGHT CONCRETE SHALL
BE LIGHTWEIGHT AGGREGATE COMPLYING WITH ASTM C330.
PROVIDE PORTLAND CEMENT COMPLYING WITH ASTM C150, TYPE II OR TYPE V.
PROVIDE TYPE V CEMENT AT CONCRETE IN CONTACT WITH EARTH.
PROVIDE CONCRETE WITH THE FOLLOWING MINIMUM COMPRESSIVE STRENGTH
(f'c) AT 28 DAYS UNLESS NOTED OTHERWISE:
LOCATION OF CONSTRUCTION JOINTS SHALL BE APPROVED BY THE ARCHITECT
(STRUCTURAL ENGINEER) PRIOR TO PLACING REINFORCING STEEL. PROVIDE
KEYS IN CONSTRUCTION JOINTS UNLESS NOTED OTHERWISE. ROUGHEN CONCRETE
SURFACE TO 1/4 INCH AMPLITUDE. THOROUGHLY CLEAN, REMOVE LAITANCE, AND
THOROUGHLY WET AND REMOVE STANDING WATER PRIOR TO PLACING NEW CONCRETE.
4. FLY ASH:
CLASS F FLY ASH COMPLYING WITH ASTM C618 IS…