A03 - 892CM3036 - Bid Documents Plans - C-201.pdf
PDF 1 MB Posted
- Solicitation number
- 36C78620B0015
About this file
This document package includes construction bid documents and plans for the Miramar National Cemetery Expansion project along with the corresponding federal contract opportunity notice. The bid documents detail utility plans for wet utilities including proposed 3-inch PVC water and 8-inch PVC reclaimed water lines, blow off assemblies, air/vacuum valves, thrust blocks, gate valves, and storm drain references. The project will connect to existing 3-inch water and 8-inch reclaimed water lines. The federal contract opportunity is solicitation number 36C78620B0015 for cemetery expansion work including new columbarium niches and in-ground cremains areas. The Department of Veterans Affairs National Cemetery Administration is the contracting agency. The project number is 892-036.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T F
BF390
371372373374376
391 391
Revisions Date
Approved: Director, Project Management Service
Approved: Director, Office of Construction Management
Drawing Title
OfDwg.
Building Number
Location
Project Title
Checked DRAWING NO.
Project No.
Date
Drawn
892CM3036
Pl ott ed : 8
/17 /20 at 2:
pm
B y:
jsu nw oo Fil e:
L:\
1.0
Pr oje cts \20
-0
4 -
M ira ma r N
C Ph as e I
I\A
CA
D\ Pl an s\B id Do cs \89
2C M3
6-
El ec tric al
Ut ilit y P lan
S he ets .dw g
ENGINEER OF RECORDCONSULTANTS
BID DOCUMENTS
TERRACON
1421 EDINGER AVENUE, SUITE C
TUSTIN CA 92780
(949) 383-1990
2 2 5 M i l l e r A v e n u e , M i l l V a l l e y , C A 9 4 9 4 1 T 415 383 7900 F 415 383 1433 www.rhaa.com
MAY 2020
MIRAMAR NATIONAL CEMETERY
5795 NOBEL DRIVE
SAN DIEGO, CALIFORNIA 92122
COLUMBARIUM AND CREMAINS
EXPANSION
ENGINEERED WITH LAYTON
1490 S PRICE RD, SUITE 215
CHANDLER, AZ 85286 NA NEL JHS
C-201
WET UTILITY PLAN 1
SEE SHEET C-202
C-201
C-202
C-203
1"=600'
UTILITY KEY MAP
AutoCAD SHX Text 392.03
AutoCAD SHX Text
AutoCAD SHX Text
20' PIPELINE EASEMENT RECORDED AUGUST 24, 2007 AS DOC. NO. 2007-0565901
AutoCAD SHX Text 40'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text T
AutoCAD SHX Text F
AutoCAD SHX Text T
AutoCAD SHX Text F
AutoCAD SHX Text 114+00
AutoCAD SHX Text 100+00
AutoCAD SHX Text 101+00
AutoCAD SHX Text 102+57.27
AutoCAD SHX Text 10+00
AutoCAD SHX Text 101+00
AutoCAD SHX Text 102+00
AutoCAD SHX Text
40' UTILITY EASEMENT
AutoCAD SHX Text
EXISTING STORM DRAIN
AutoCAD SHX Text
EXISTING STORM DRAIN
AutoCAD SHX Text
MICHAEL MONSOOR AVENUE
AutoCAD SHX Text
"A" ROAD
AutoCAD SHX Text
"L" ROAD
AutoCAD SHX Text
COMMITTAL SHELTER
AutoCAD SHX Text
ASSEMBLY AREA
AutoCAD SHX Text
STA 102+32.69 ROAD 'D' CL 7.15' RT, 3" WATER END CAP
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING 8" PVC RECLAIMED WATER
AutoCAD SHX Text
EXISTING 3" PVC WATER
AutoCAD SHX Text
STA 101+30.28 ROAD 'C' CL 7.50' RT WATER ADDITION TO EXIST
AutoCAD SHX Text
STA 101+35.00 ROAD 'C' CL 2.50' RT RW ADDITION TO EXIST
AutoCAD SHX Text
AutoCAD SHX Text
STA 102+35.80 FIELD DEFLECT
AutoCAD SHX Text
NEW 3" PVC WATER 3.5' MIN COVER
AutoCAD SHX Text
AutoCAD SHX Text
NEW 8" PVC RECLAIMED WATER 5.5' MIN COVER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STA 102+32.69 ROAD 'D' CL 2.15' RT, 8" RW END CAP
AutoCAD SHX Text
NEW 8" PVC RECLAIMED WATER 5.5' MIN COVER
AutoCAD SHX Text
NEW 3" PVC WATER 3.5' MIN COVER
AutoCAD SHX Text
"D" ROAD
AutoCAD SHX Text
EXISTING CTS
AutoCAD SHX Text
EXISTING 8" PVC RECLAIMED WATER
AutoCAD SHX Text
EXISTING 3" PVC WATER
AutoCAD SHX Text
EXISTING STORM DRAIN
AutoCAD SHX Text
EXISTING RECLAIMED WATER AIR-VAC
AutoCAD SHX Text
MASTER PLAN PROJECT FOOTPRINT
AutoCAD SHX Text 102+00
AutoCAD SHX Text 103+00
AutoCAD SHX Text
STA 101+42.18 45 DEGREE EL
AutoCAD SHX Text 102+30.74
AutoCAD SHX Text 103+06.00
AutoCAD SHX Text
AutoCAD SHX Text 101+09.53
AutoCAD SHX Text
RW LINE #RW1 FOR PROFILE SEE SHEET C-301
AutoCAD SHX Text
WATER LINE #W1 FOR PROFILE SEE SHEET C-301
AutoCAD SHX Text
RW LINE #RW2 FOR PROFILE SEE SHEET C-301
AutoCAD SHX Text
WATER LINE #W2 FOR PROFILE SEE SHEET C-301
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NEW 12" STORM DRAIN
AutoCAD SHX Text
NEW 18" STORM DRAIN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CONNECT TO EXISTING UNDERGROUND CONDUIT STUB
AutoCAD SHX Text
EXISTING SPARE DUCT (1) 2"C.O. WITH PULL CHORD
AutoCAD SHX Text EXISTING BRANCH CIRCUIT POWER PULL BOX 24"X36" PRECAST CONCRETE WITH TRAFFIC COVER
AutoCAD SHX Text BRANCH CIRCUIT POWER DUCT (1) 2" C. PVC SCHEDULE 40 WITH (3) #8 & (1) #8 GROUND WIRE
AutoCAD SHX Text
BRANCH CIRCUIT POWER PULL BOX 24"X36" PRECAST CONCRETE WITH TRAFFIC COVER
AutoCAD SHX Text
BRANCH CIRCUIT POWER PULL BOX 24"X36" PRECAST CONCRETE WITH TRAFFIC COVER
AutoCAD SHX Text BRANCH CIRCUIT POWER DUCT (1) 2" C. PVC SCHEDULE 40 WITH (3) #8 & (1) #8 GROUND WIRE
AutoCAD SHX Text BRANCH CIRCUIT POWER DUCT (1) 2" C. PVC SCHEDULE 40 WITH (2) #10 & (1) #10 GROUND WIRE
AutoCAD SHX Text POWER DISCONNECT SWITCH, 20A, 1-POLE, 120V CIRCUIT BREAKER IN NEMA 1 CLOSURE, INSIDE STORE ROOM
AutoCAD SHX Text Huitt-Zollars, Inc. Irvine
AutoCAD SHX Text Phone (949) 988-5815 Fax (949) 988-5820
AutoCAD SHX Text 2603 Main Street, Suite 400
AutoCAD SHX Text Irvine, California 92614-4250
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text
ATIONAL
AutoCAD SHX Text
EMETERY
AutoCAD SHX Text
DMINISTRATION
AutoCAD SHX Text
SCALE 1"=
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 20'
AutoCAD SHX Text
AutoCAD SHX Text WET UTILITY CONSTRUCTION NOTES: PROPOSED 3" PVC WATER SERVICE PROPOSED 8" PVC RECLAIMED WATER SERVICE BLOW OFF ASSEMBLY PER SDRSD SDW-146 AIR/VACUUM VALVE PER SDRSD SDW-117 & SDW-159 THRUST BLOCK PER SDRSD SDW-151 8" GATE VALVE 3" WATER LATERAL FOR FWS CONNECT TO EXISTING 3" PVC WATER LINE CONNECT TO EXISTING 8" PVC RECLAIMED WATER LINE NOTE: STORM DRAIN SHOWN FOR REFERENCE ONLY. SEE SHEETS C-204, C-205, C-206, AND C-206 FOR STORM DRAIN PLANS. CAUTION!: VERIFY EXACT LOCATION AND DEPTH OF EXISTING UTILITIES PRIOR TO ANY EXCAVATION IN AN EASEMENT.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text LEGEND: CATCH BASIN CAP BLOW OFF THRUST BLOCK GATE VALVE MANHOLE AIR/VACUUM VALVE WATER LINE RECLAIMED WATER LINE STORM DRAIN
AutoCAD SHX Text
W RW SD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ADDED ELECTRICAL CONNECTION TO COMMITTAL SHELTER
AutoCAD SHX Text
17 AUG '20
| Sheets and Views |
| C-201 |
File details come from the government source that posted it. Updated .