This document package includes construction drawings and specifications for facility renovations, improvements, and repairs at the Woodlawn National Cemetery. The project involves demolishing existing mechanical, plumbing, and HVAC systems in the administration building including radiators, boilers, ductwork, and flues. It also includes installing new fire alarms, telecommunications, security, data cabling, and electrical systems in the administration building and temporary office trailer. Mechanical plans show proposed locations for new HVAC equipment. Telecommunications drawings provide specifications for a new network video recorder, switches, and IP cameras. The opportunity is solicited by the Department of Veterans Affairs National Cemetery Administration for contract number 36c78620b0009.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADMIN METER
PULL NEW 200 AMP FEEDER
THROUGH EXISTING 2" CONDUIT.
200N 200N
100N
60N
100N
100N 200N
H.F. LENZ COMPANY, P.C.
1407 Scalp Avenue, Johnstown, PA 15904 Phone: 814-269-9300
FAX: 814-269-9301
LEGEND
NOTES
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
DRAWING NO.
Dwg. Of
Walker Federal Services, LLC
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
DRAWING NO.
Dwg. Of
N C A
ATIONAL
EMETERY
DMINISTRATION
N C A
ATIONAL
EMETERY
DMINISTRATION
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
803IC3005
GGG BLP
May 22, 2020
1 DEMOLITION RISER DIAGRAM - ELECTRICAL
NOT TO SCALE
2 NEW WORK RISER DIAGRAM - ELECTRICAL
NOT TO SCALE
ELECTRICAL RISER DIAGRAMS
EP-204
ST
ST
ST
ST
ST ST
W W W
W
EEEE
E E E E E
E
A-28
A-29
FINAL CONNECTION TO FUEL PUMP
FED VIA EXISTING 1" CONDUIT
H.F. LENZ COMPANY, P.C.
1407 Scalp Avenue, Johnstown, PA 15904 Phone: 814-269-9300
FAX: 814-269-9301
LEGEND
NOTES
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
DRAWING NO.
Dwg. Of
Walker Federal Services, LLC
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
DRAWING NO.
Dwg. Of
N C A
ATIONAL
EMETERY
DMINISTRATION
N C A
ATIONAL
EMETERY
DMINISTRATION
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
803IC3005
GGG BLP
May 22, 2020
SITE ELECTRICAL PLAN
ES-101
0 5' 10' 20' 30'
3"
1-WAY DUCT LINE
NOTES:
1. CONCRETE SHALL BE 2500 P.S.I. @ 28 DAYS.
2. PROVIDE REINFORCING RODS ON TOP OF DUCTS WHEN CROSSING OR
PLACED IN ROADWAYS. REFER TO SPECIFICATIONS FOR MORE INFO.
3. MINIMUM COVER TO TOP OF ENVELOPE SHALL BE 24" [610mm].
4. IMBED NON-FERROUS TIE WIRES IN DUCT BED CONCRETE.
[7 6m m
[7 6m m
(T
YP
[76mm]
TIE WIRE
3"
2-WAY DUCT LINE
NOTES:
1. CONCRETE SHALL BE 2500 P.S.I. @ 28 DAYS.
2. PROVIDE REINFORCING RODS ON TOP OF DUCTS WHEN CROSSING OR
PLACED IN ROADWAYS. REFER TO SPECIFICATIONS FOR MORE
INFORMATION.
3. MINIMUM COVER TO TOP OF ENVELOPE SHALL BE 24" [610mm].
4. IMBED NON-FERROUS TIE WIRES IN DUCT BED CONCRETE.
5. PROVIDE MINIMUM 6" [152mm] SPACE BETWEEN POWER AND
TELECOMMUNICATION DUCTS.
6. INNERDUCT QUANTITY AND SIZE AS INDICATED ON PLANS.
[7 6m m
[7 6m m
(T
YP
[76mm]
TIE WIRE
3" [76mm]
DUCT [SIZE AS
INDICATED ON
DWGS.]
3" [76mm]
3" [76mm]
DUCT [SIZE AS
INDICATED ON
DWGS.]
H.F. LENZ COMPANY, P.C.
1407 Scalp Avenue, Johnstown, PA 15904 Phone: 814-269-9300 FAX: 814-269-9301Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
DRAWING NO.
Dwg. Of
Walker Federal Services, LLC
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
DRAWING NO.
Dwg. Of
N C A
ATIONAL
EMETERY
DMINISTRATION
N C A
ATIONAL
EMETERY
DMINISTRATION
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
803IC3005
GGG BLP
May 22, 2020
SITE ELECTRICAL DETAILS
ES-201
1 DUCTBANK SECTION 1
NOT TO SCALE
2 DUCTBANK SECTION 2
NOT TO SCALE
SYMBOLS ABBREVIATIONS
TELEPHONE OUTLET - WALL MOUNTED, M.H. 48" AFF, UON.
DATA OUTLET - WALL MOUNTED, M.H. 48" AFF, UON.
FLOOR MOUNTED DATA OUTLET.
TELEPHONE/DATA OUTLET - WALL MOUNTED, M.H. 18" AFF, UON.
PROVIDE 1" EC FROM THE OUTLET TO 6" ABOVE FINISHED CEILING AND
TERMINATE WITH 90° BEND AND INSULATED BUSHING.
AFF
ANSI
ASME
ASTM
BICSI
EIA
FCC
ISSS
ISO
NEC
NEMA
NESC
NFPA
OSHA
POE
RUS
SMPTE
TIA
UL
UON
ABOVE FINISHED FLOOR
AMERICAN NATIONAL STANDARDS INSTITUTE
AMERICAN SOCIETY OF MECHANICAL ENGINEERS
AMERICAN SOCIETY FOR TESTING MATERIALS
BUILDING INDUSTRY CONSULTING SERVICES INTERNATIONAL
ELECTRONICS INDUSTRY ASSOCIATION
FEDERAL COMMUNICATIONS COMMISSION
INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS
INTERNATIONAL STANDARDS ORGANIZATION
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION
NATIONAL ELECTRICAL SAFETY CODE
NATIONAL FIRE PROTECTION ASSOCIATION
OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
POWER OVER ETHERNET
RURAL UTILITY SERVICE (FORMERLY AREA)
SOCIETY OF MOTION PICTURE AND TELEVISION ENGINEERS
TELECOM INDUSTRY ASSOCIATION
UNDERWRITER'S LABORATORIES, INC.
UNLESS OTHERWISE NOTED
TELECOM GENERAL NOTES
1. ALL CABLE PATHWAYS ARE DESIGNED WITH A MAXIMUM 40 PERCENT FILL RATIO UNLESS
OTHERWISE NOTED. FILL REQUIREMENTS MAY ALTER FROM INITIAL DESIGN DUE TO COR'S
REQUIREMENTS DURING INSTALLATION.
2. ALL CABLE PATHWAYS SHALL BE FREE FROM PROJECTIONS AND ROUGH OR SHARP EDGES
THROUGHOUT THE ENTIRE PATH. ALL POINTS OR EDGES THAT CABLING MUST PASS, AND
MAY BE SUBJECT TO INJURY OR WEAR, SHALL BE ROUNDED, PADDED, OR BUSHED.
3. THE TELECOM DRAWINGS INDICATE THE GENERAL LOCATION OF EQUIPMENT, CABLE
PATHWAYS, AND OUTLETS. ALTHOUGH THE DRAWINGS DO NOT NECESSARILY DICTATE THE
ACTUAL ROUTES OF CABLE TRAYS AND CONDUITS, LOCATION OF EQUIPMENT AND OUTLETS,
AND OTHER SUPPORTING ITEMS. FOLLOW THE DESIGN IN THIS DOCUMENTS AS CLOSELY AS
POSSIBLE. COORDINATE TO THE NEAREST INSTALLATION OF TELECOM ITEMS WITH THOSE OF
ALL OTHER TRADES.
4. ALL BLOCKS, PANELS AND CABLE SHALL BE ASSIGNED, LABELED AND RECORDED BY THE
INSTALLING CABLE CONTRACTOR, AND DELIVERED TO THE ENGINEER.
5. SEE NOTES ON INDIVIDUAL DRAWINGS FOR CROSS REFERENCE TO PERTINENT DETAILS,
SECTIONS, ETC. SHOWN ON OTHER DRAWINGS IN THIS DRAWING SET.
6. SCALES NOTED ON THE TELECOM DRAWING ARE FOR GENERAL INFORMATION AND USED
FOR REFERENCE ONLY.
7. ALL MOUNTING HEIGHTS SHOWN ARE MEASURED FROM FINISHED FLOOR TO BOTTOM OF
MOUNTED EQUIPMENT UNLESS OTHERWISE NOTED.
8. FIRE STOP ALL STRUCTURE PENETRATIONS WITH FIRE STOPPING MATERIAL EQUAL TO OR
GREATER THAN THAT OF PENETRATED STRUCTURE. INSTALL FIRE STOPPING MATERIAL AFTER
COMPLETE INSTALLATION OF CABLING. USE ONLY LISTED FIRE STOPPING MATERIAL IN
ACCORDANCE WITH UL, AND OTHER AUTHORITIES HAVING JURISDICTION.
9. TELECOM ROOMS SHALL NOT BE USED AS STORAGE SPACE BY ANY CONTRACTOR EXCLUDING
THE INSTALLING CONTRACTOR FOR THE TELECOM SYSTEMS. WHEN THE INSTALLATIONS OF
A TELECOM SPACE IS COMPLETE, ALL ITEMS AND EQUIPMENT NOT SUPPORTING THE
FUNCTIONS OF THAT SPACE SHALL BE REMOVED FROM THE SPACE.
10. ALL NEW TELECOM AND SECURITY ROOMS/CLOSETS WILL HAVE 1-HOUR FIRE RATED WALLS.
SEE ARCHITECTURAL DRAWINGS FOR DETAILS.
11. THE TELECOM DRAWINGS INDICATE THE GENERAL LOCATION OF THE BACKBONE CONDUIT
FOR THE TELECOM ROOMS. VERIFY THE EXACT LOCATION OF THE CONDUIT (S). POSITION
CONDUITS SO THEY ENTER AND EXIT TELECOM ROOMS IN THE CORNERS AS SHOWN ON THE
TELECOM ROOM DRAWINGS.
12. NOT ALL HARDWARE FOR INSTALLATION IS IDENTIFIED/SHOWN. PROVIDE ALL MOUNTING
HARDWARE REQUIRED FOR A COMPLETE AND PROPERLY OPERATING INSTALLATION.
13. NOT ALL ITEMS, COMPONENTS AND SYSTEMS SPECIFIED IN THIS DRAWING SET OR THE
SPECIFICATIONS ARE DETAILED. PROVIDE MANUFACTURER'S SPECIFICATIONS AND DETAIL
SHEETS IN THE PRECONSTRUCTION SUBMITTALS FOR SELECTION PER THE SPECIFICATIONS.
14. INSTALL COMPONENTS OR SYSTEMS PER THE MANUFACTURE'S INSTALLATION
INSTRUCTIONS OR SPECIFICATIONS.
15. ALL CABLE SHALL COMPLY WITH THE SPECIFICATIONS AND SHALL BE SUITABLE AND LISTED
FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED.
16. ALL CONDUIT RUNS SHALL FOLLOW BICSI STANDARDS FOR BENDS, FILL AND JUNCTION BOX
PLACEMENT. NO CONDUIT RUNS SHALL HAVE GREATER THAN 180 DEGREES OF BEND
WITHOUT A PROPERLY SIZED AND PLACED BOX.
17. ALL CONDUIT RUNS AND CABLE TRAY SHOWN ARE DIAGRAMMATICAL. REPORT ANY MAJOR
DEVIATION TO CONSTRUCTION MANAGER FOR APPROVAL..
18. ALL CONDUITS FROM BELOW SHALL STUB UP 4" A.F.F.
19. COORDINATE FINAL SYSTEMS, EQUIPMENT LAYOUT AND CONDUIT ROUTING AS SHOWN ON
DRAWING WITH SITE CONDITIONS.
20. ENSURE PROPER SEPARATION OF CLASS 1, CLASS 2, AND CLASS 3 CIRCUITS PER NEC 725-54.
21. VERIFY THE SIZE OF ALL CONDUCTORS, CONDUIT,L AND JUNCTION BOXES (40% MAXIMUM
FILL). INSTALLATION SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE (NEC)
AND ALL LOCAL CODES HAVING JURISDICTION.
22. DO NOT INSTALL LOW VOLTAGE VOICE AND DATA CABLING IN THE SAME CONDUITS AS 120
VAC POWER CABLES.
23. PROMPTLY NOTIFY COR PRIOR TO INSTALLATION OF WORK IF ANY MOUNTING LOCATIONS
NOTED ON THE DRAWINGS ARE OBSTRUCTED AND/OR IF ANY CONFLICTS OR PROBLEMS ARE
DISCOVERED.
24. PROVIDE AND INSTALL EQUIPMENT AND HARDWARE IN ORDER TO MEET THE INTENT OF THE
DESIGN AND TO PROVIDE GOVERNMENT WITH A COMPLETE AND FULLY OPERATIONAL
CABLING SYSTEM AS SPECIFIED. PROMPTLY ADDRESS ANY QUESTIONS REGARDING THE
INTENT OF THE DESIGN TO THE COR.
25. PROVIDE A SINGLE GANG BOX WITH A CONDUIT TO THE NEAREST ACCESSIBLE CEILING FOR
ANY DEVICE SHOWN ON THESE DRAWINGS THAT IS LOCATED IN AN OPEN OR HARD CEILING
SPACE.
1. COORDINATE EXACT REQUIREMENTS FOR INCOMING SERVICE OF LOCAL UTILITIES FOR POWER AND
TELEPHONE, PAY ALL FEES, AND INSTALL A COMPLETE AND FUNCTIONAL SYSTEM.
2. COORDINATE INSTALLATION OF TELEPHONE SYSTEM INCLUDING TELEPHONE WIRING AND TELEPHONE
OUTLETS WITH THE GOVERNMENT/ENGINEER.
3. REFER TO BASE BUILDING DRAWINGS FOR LOCATION OF UTILITY SERVICE JUNCTION BOX.
COORDINATION WITH TELEPHONE COMPANIES
CONSTRUCTION SEQUENCE
1. ALL OUTAGES MUST BE PERFORMED OUTSIDE THE NORMAL BUSINESS HOURS
UNLESS OTHERWISE AUTHORIZED BY COR.
2. SCHEDULE A SHORT OUTAGE. COORDINATE WITH DATA/TELECOM SERVICE
PROVIDER FOR THEM TO SPLICE EXISTING SERVICE CABLES TO EXTEND AT
TEMPORARY TRAILER.
3. SETUP NEW MODEM AND DATA/TELECOM DISTRIBUTION NETWORK AT
TEMPORARY TRAILER.
4. REPLACE EXISTING DATA/TELECOM EQUIPMENT AS SHOWN ON DRAWING ET-201
AT ADMINISTRATION BUILDING. ALL SERVICES TO TRAILER MUST NOT BE
DISTURBED DURING WORK AT ADMINISTRATION BUILDING.
5. MAINTAIN EXISTING OR PROVIDE NEW UTILITIES, SYSTEMS, AND SERVICES TO
OCCUPIED SPACES AT ALL TIMES. NO OUTAGES ARE PERMITTED DURING
NORMAL BUSINESS HOURS. COORDINATE ALL OUTAGES DURING CHANGE-OVERS
BETWEEN EXISTING BUILDING AND TEMPORARY FACILITIES WITH CEMETERY
DIRECTOR NOT LESS THAN 7 DAYS IN ADVANCE.
6. AFTER ALL UPGRADES OF ADMINISTRATION BUILDING EQUIPMENT, REMOVE
TEMPORARY SPLICE FOR TRAILER AND TURN OVER TO NCA ALL THE IT/TELECOM
EQUIPMENT INSTALLED IN THE TRAILER BY CONTRACTOR WHEN TRAILER IS
REMOVED FROM SERVICE.
7. FOR DATA/TELECOM SYSTEM DIAGRAM, SEE DRAWING ET-301.
TELECOM SYMBOLS,
ABBREVIATIONS AND
GENERAL NOTES
ET-001
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
FINAL CONSTRUCTION DOCUMENTS
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2019, Walker Federal Serivces, LLC
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
824IC3005
HU UB
May 22, 2020
05/22/2020
DS
DS
DS
DS
RA
M
P
DN
DN
KITCHEN
UTILITY RM
RESTROOM
LOBBY
OFFICE
RESTROOM
OFFICE
OFFICE
HALL
CLOSET
108A
CLOSET
109A
CLOSET
110A
CLOSET
102A
ENT. PORCH
104B
PORCH
109B
DN
DN
CLOSET
107A
LOUNGE
1 ADMINISTRATION BUILDING FLOOR DEMO PLAN
1/4" = 1'-0"
ADMINISTRATION BUILDING
TELECOM DEMOLITION PLAN
ET-101
GENERAL NOTES
1. FOR TELECOMMUNICATION SYMBOLS, ABBREVIATIONS AND GENERAL NOTES, SEE
DRAWING ET-001.
2. FOR TELECOMMUNICATION NEW WORK PLANS, SEE DRAWING ET-201.
3. FOR TELECOMMUNICATION DETAILS, SEE DRAWING ET-301.
KEY NOTES
DISCONNECT AND REMOVE EXISTING TELEPHONE AND DATA OUTLETS AS
INDICATED. DEMOLITION SHALL BE COMPLETE INCLUDING GANG BOX, COVER
PLATE AND PULLING WIRING BACK TO SOURCE AND DISPOSAL THEREOF.
DISCONNECT AND RELOCATE EXISTING VERIZON TELECOM MODEM AS SHOWN
ON DRAWING E-201.
PROTECT EXISTING DATA SIGNAL MODEM AND T-1 CABLE FOR RE-USE.
DISCONNECT AND REMOVE EXISTING INTEGRATED SERVICE ROUTER, ETHERNET
NETWORK SWITCH, CONNECTOR PORT, UPS AND ALL WIRING/CONNECTIONS
LOCATED IN IT CLOSET (105A).
FOR CONSTRUCTION SEQUENCE, SEE DRAWING ET-001.
WARNING. EXISTING PIPE WRAP IN THE CRAWLSPACE MAY CONTAIN ASBESTOS.
DO NOT DISTURB. PIPE WRAP WILL BE REMOVED DURING SUBSEQUENT
PLUMBING DEMOLITION UNLESS OTHERWISE INDICATED.
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
FINAL CONSTRUCTION DOCUMENTS
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2019, Walker Federal Serivces, LLC
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
824IC3005
HU UB
May 22, 2020
05/22/2020
0 2' 4' 8' 12'
DEMOLITION - TELEPHONE OUTLET
DEMOLITION - DATA OUTLET
DEMOLITION - TELEPHONE AND DATA OUTLET
LEGEND
(TYP.)
(TYP.)
TELECOM
EQUIPMENT
DATA/COMMUNICATION
EQUIPMENT 03
DS
DS
DS
RA
M
P
DN
DN
REF
CLOSET
104A
KITCHEN
UTILITY RM
RESTROOM
LOBBY
OFFICE
RESTROOM
OFFICE
OFFICE
HALL
CLOSET
108A
CLOSET
109A
CLOSET
110A
IT CLOSET
105A
CLOSET
102A
ENT. PORCH
104B
PORCH
109B
DN
DN
CLOSET
107A
LOUNGE
T
DS DS DS DS DS
T T
T T
T
T
1 ADMINISTRATION BUILDING - FLOOR PLAN
1/4" = 1'-0"
TELECOM PLANS
ET-201
0 2' 4' 8' 12'
GENERAL NOTES
1. FOR TELECOMMUNICATION SYMBOLS, ABBREVIATIONS AND GENERAL
NOTES, SEE DRAWING ET-001.
2. FOR TELECOMMUNICATION DEMOLITION PLAN, SEE DRAWING ET-101.
3. FOR TELECOMMUNICATION DETAILS, SEE DRAWING ET-301.
4. ALL CABLING IN TRAILER SHALL BE DONE ABOVE CEILING AND WIREMOLD
FROM CEILING TO NEW BOXES.
KEY NOTES
INSTALL NEW TELEPHONE AND DATA OUTLETS AS SHOWN. INSTALL CATEGORY 6
CABLES FOR DATA AND RJ12 FOR VOICE. AT THE DEVICE LOCATION, TERMINATE
CABLES WITH CATEGORY 6 JACKS INSTALLED IN A SINGLE-GANG FACEPLATE
MOUNTED AT 18" AFF, UON.
RELOCATE EXISTING VERIZON TELECOM MODEM ON NEW WALL MOUNTED RACK IN
IT CLOSET(105A). FOR MORE DETAILS, SEE TELECOMMUNICATION SYSTEM
DIAGRAM ON DWG ET-301. FOR RACK DETAILS, SEE DWG EY-201.
PROVIDE NEW INTEGRATED SERVICE ROUTER , ETHERNET NETWORK SWITCH AND
UPS. CONTRACTOR SHALL MAKE CONNECTION BETWEEN ALL EQUIPMENT LOCATED
IN IT CLOSET (105A). FOR MORE DETAILS, SEE DATA SYSTEM DIAGRAM ON DWG
ET-301.
COORDINATE FINAL INSTALLATION WITH TELEPHONE, NETWORK AND SECURITY
CONTRACTORS. INSTALL TELEPHONE, DATA EQUIPMENT, FLOOR MOUNTED IT
RACK, WALL MOUNTED RACK, SERVER AND UPS IN IT CLOSET (105A).
PROVIDE NEW LOCKABLE, WALL MOUNTED RACK LOCATED AT DIRECTOR'S OFFICE,
SIZE AS REQUIRED TO ACCOMMODATE ALL IT AND TELECOMMUNICATION
EQUIPMENT. TRAILER SUPPLIER TO PROVIDE SERVICE ENTRANCE JUNCTION BOX
FOR DATA AND COMMUNICATION CABLES AT LOCATION INDICATED. CONTRACTOR
TO EXTEND CABLES FROM JUNCTION BOX TO WALL MOUNTED RACK.
PROVIDE NEW DATA AND TELECOM MODEM INSIDE THE WALL MOUNTED RACK.
CONTRACTOR SHALL PROVIDE NEW 12 PORT ETHERNET SWITCH, PATCH PANEL
AND TELECOM DISTRIBUTION MODULES INSIDE THE RACK. CONTRACTOR SHALL
PROVIDE ALL DATA AND TELECOM SERVICE WIRING AND CONDUIT FROM
ADMINISTRATION BUILDING TO WALL MOUNTED RACK IN TRAILER. PROVIDE ANY
OTHER REQUIRED INTERNAL WIRING INSIDE THE RACK.
TRAILER SUPPLIER SHALL PROVIDE ALL DATA AND TELECOM OUTLETS, LOCATION AS
SHOWN AND WIRING AND CONDUIT TO OUTLETS AND ANY OTHER EQUIPMENT TO
PROVIDE COMPLETE DATA AND TELECOMMUNICATION SYSTEM AT TRAILER.
FOR CONSTRUCTION SEQUENCE, SEE DRAWING ET-001.
FOR DATA/TELECOM SYSTEM DIAGRAM, SEE DRAWING ET-301.
FOR ROUTE OF CABLES, SEE ELECTRICAL SITE PLAN.
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
FINAL CONSTRUCTION DOCUMENTS
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2019, Walker Federal Serivces, LLC
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
824IC3005
HU UB
May 22, 2020
05/22/2020
TELEPHONE OUTLET - WALL MOUNTED
DATA OUTLET - WALL MOUNTED
TELEPHONE AND DATA OUTLET - WALL MOUNTED
LEGEND
(TYP.)
(TYP.)
(TYP.)
2 TEMPORARY OFFICE TRAILER - FLOOR PLAN
3" = 1'-0"
DATA/COMMUNICATION
EQUIPMENT
03 04
TELECOM
MODEM 02 04
SERVICE ENTRANCE
JUNCTION BOX
TELECOM
DISTRIBUTION MODULE
ETHERNET SWITCH
DATA SIGNAL MODEM
TELECOM MODEM
08 (TYP.)
WALL MOUNTED
RACK 05
DATA AND TELECOM
CABLES FROM ADMINISTRATION BUILDING
DATA AND TELECOM
CABLES TO TEMPORARY OFFICE TRAILER
09 10
EXISTING DATA SIGNAL
MODEM
(VISUAL UPTIME SELECT
FLUKE T-1 CSU/DSU)
IT/DATA SERVICE
PROVIDER
EXISTING T-1 CABLE
FROM SMARTJACK OR
TELEPHONE BISCUIT
ON WALL
NEW INTEGRATED SERVICE
ROUTER
(CISCO 4351)
NEW ETHERNET NETWORK
SWITCH
(CISCO 3850 24 PORT OR
EQUAL)
V.35 CISCO CABLE
CAT 6 ETHERNET CABLE
TO DATA OUTLETS
CAT 6E CABLE
120V AC
FROM UPS
RELOCATED EXISTING
TELECOM
MODEM
TELECOM SERVICE
PROVIDER
EXISTING T-1 CABLE
FROM SMARTJACK
OR TELEPHONE
BISCUIT ON WALL
TO TELEPHONE OUTLETS
RJ12 CABLE
120V AC
FROM UPS NEW
DATA SIGNAL MODEM
NEW ETHERNET NETWORK
SWITCH AND PATCH PANEL
(CISCO 3850 12 PORT OR
EQUAL)
TO DATA OUTLETS
BY TRAILER SUPPLIER
CAT 6E CABLE
BY TRAILER
SUPPLIER
120V AC
FROM UPS
ADMINISTRATION BUILDING TRAILER
JBFLOOR MOUNTED IT RACK
BY CONTRACTOR WALL MOUNTED RACK
BY CONTRACTOR
WALL MOUNTED RACK
BY CONTRACTOR
NEW
TELECOM MODEM
NEW TELECOM
DISTRIBUTION MODULE
JB
WALL MOUNTED RACK
BY CONTRACTOR
ADMINISTRATION BUILDING TRAILER
NEW TELEPHONE
CONNECTION BOX
RJ12 CABLE
BY TRAILER
SUPPLIER
TO TELEPHONE OUTLETS
BY TRAILER SUPPLIER
SPLICE BY
SERVICE PROVIDER
SPLICE BY
SERVICE PROVIDERSERVICE ENTRANCE
JUNCTION BOX
BY TRAILER SUPPLIER
SERVICE ENTR
JUNCTION BO
BY TRAILER SU
BY CONTRACTOR BY CONTRACTOR
BY CONTRACTOR
BY CONTRACTOR
BY CONTRACTOR
BY CONTRACTOR
BY CONTRACTOR BY CONTRACTOR
BY CONTRACTOR BY CONTRACTOR
TELECOM DETAILS
ET-301
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
FINAL CONSTRUCTION DOCUMENTS
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2019, Walker Federal Serivces, LLC
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
824IC3005
HU UB
May 22, 2020
05/22/2020
1 BOX AND CONDUIT INSTALLTION DETAIL
NONE
ACCESSIBLE
CEILING
FACE PLATE
FISHABLE WALL
SINGLE-GANG
REDUCER RING
DOUBLE-GANG BOX
MINIMUM 1" CONDUIT STUBBED TO ACCESSIBLE
CEILING (USE 1-1/4" CONDUIT FOR
MORE THAN 7 CABLES)
3 DATA SYSTEM DIAGRAM
NONE
RJ45 TELEPHONE JACK (IVORY),
WITH RJ12 CABLES (YELLOW)
TELECOMMUNICATION PIN ASSIGNMENT
STANDARD : T568A
DATA JACK (BLUE),
WITH CAT 6E (WHITE)
SERIES: MINI COM,
CABLE TYPE: CATEGORY 6,
HUBBELL MODEL # HXJ6B OR EQUAL
RJ45 TELEPHONE JACK (IVORY),
WITH RJ12 CABLES (YELLOW)
TELECOMMUNICATION PIN
ASSIGNMENT STANDARD : T568A
RJ45 TELEPHONE JACK (IVORY),
WITH RJ12 CABLES (YELLOW)
TELECOMMUNICATION PIN
ASSIGNMENT STANDARD : T568A
DATA JACK (BLUE),
WITH CAT 6E (WHITE)
SERIES:MINI COM,
CABLE TYPE: CATEGORY 6,
HUBBELL MODEL # HXJ6B OR EQUAL
COMBINATION OF
TELEPHONE/DATA OUTLET
DUPLEX TELEPHONE
OUTLET
DUPLEX DATA
OUTLET
4 FACE PLATE DETAILS
NONE
2 TELECOMMUNICATION SYSTEM DIAGRAM
NONE
DATA JACK (BLUE),
WITH CAT 6E (WHITE)
SERIES:MINI COM,
CABLE TYPE: CATEGORY 6,
HUBBELL MODEL # HXJ6B OR EQUAL
GENERAL NOTES
1. FOR TELECOMMUNICATION SYMBOLS, ABBREVIATIONS AND GENERAL
NOTES, SEE DRAWING ET-001.
2. FOR TELECOMMUNICATION DEMOLITION PLAN, SEE DRAWING ET-101.
3. FOR TELECOMMUNICATION NEW PLAN, SEE DRAWING ET-201.
KEY NOTES
PROVIDE EQUIPMENT/DEVICE TO MEET THE SPECIFICATIONS OF NAMED
MANUFACTURER OR APPROVED EQUAL. ALL PRODUCTS, EQUIPMENT AND DEVICES
PROVIDED UNDER THIS PROJECT SHALL CONFORM TO "BUY AMERICAN ACT".
FOR CONSTRUCTION SEQUENCE, SEE DRAWING ET-001.
FACEPLATE (IVORY, PLASTIC)
MANUFACTURE: PANDUIT
FACEPLATE (IVORY, PLASTIC)
MANUFACTURE: PANDUIT
FACEPLATE (IVORY, PLASTIC)
MANUFACTURE: PANDUIT0101 01
NOTE:
THIS DETAIL IS APPLICABLE ONLY FOR ADMINISTRATION BUILDING.
02 02
BRICK CHIMNEY
AND VENTS
GABLE VENT
GABLE VENT
A
A
A
G
G
TW
GROUNDING
TEST WELL
G
G
G
A
VENT PIPE (TYP.)
"T" JOINT
CONNECTION (TYP.)
LIGHTNING CONDUCTOR
RUN ALONG ROOF,
FASTENED EVERY
3 FEET MAX.
AIR TERMINAL (TYP.)
BONDING
PLATE (TYP.)
GROUND ROD (TYP.)
RUN DOWN CONDUCTOR TO BUILDING
GROUND RING OR BUILDING'S MAIN
GROUNDING ELECTRICAL SERVICE AND BOND.
RUN IN RIGID CONDUIT 8' FROM GROUND UP
AND EXPOSED, MOUNTED ON WALL.
G
G
VENT PIPE
G
G
G
G
A A
TW
GROUNDING
TEST WELL
G
"T" JOINT
CONNECTION (TYP.)
GROUND ROD (TYP.)
AIR TERMINAL (TYP.)
LIGHTNING CONDUCTOR
RUN ALONG ROOF,
FASTENED EVERY
3 FEET MAX.
RUN DOWN CONDUCTOR TO BUILDING
GROUND RING OR BUILDING'S MAIN
GROUNDING ELECTRICAL SERVICE AND BOND.
RUN IN RIGID CONDUIT 8' FROM GROUND UP
AND EXPOSED, MOUNTED ON WALL.
ABONDING
PLATE (TYP.)
VENT PIPE (TYP.)
G
GENERAL NOTES
LIGHTNING PROTECTION PLAN
EJ-101
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
FINAL CONSTRUCTION DOCUMENTS
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2019, Walker Federal Serivces, LLC
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
824IC3005
HU UB
May 22, 2020
05/22/2020
1. LOCATION OF VENT PIPES AND OTHER SUPER STRUCTURE ELEMENTS ARE
APPROXIMATELY SHOWN. COORDINATE ACTUAL LOCATIONS IN THE FIELD.
2. INTERCONNECT THE TELEPHONE AND ELECTRICAL SERVICE ENTRANCE GROUNDS TO
ONE LIGHTNING PROTECTION GROUND OR WATER PIPE.
3. GROUND ALL ELECTRICAL EQUIPMENT, ENCLOSURE, FRAMES AND STRUCTURES.
4. INTERCONNECT THE METAL BODIES OF INDUCTANCE LOCATED ABOUT THE ROOF
SUCH AS METAL FLASHING, GRAVEL STOPS, ROOF DRAINS, SOIL PIPE VENTS,
INSTALLATION VENTS, LOUVERS AND DOOR FRAMES SITUATED WITHIN 6'-0" OF A
LIGHTNING CONDUCTOR OR BONDED METAL BODY TO THE LIGHTNING CONDUCTOR
SYSTEM.
5. MAKE ALL UNDERGROUND OR EMBEDDED GROUNDING CONNECTIONS BY
EXOTHERMIC FUSION WELDING PROCESS, UON.
6. NO BENDS OF A CONDUCTOR SHALL FORM A FINAL INCLUDED ANGLE OF LESS THAN
90 DEGREES NOR SHALL HAVE A RADIUS OF BEND LESS THAN 8".
7. WHERE DOUBLE CONNECTIONS ARE REQUIRED, ATTACH AT DIAGONALLY OPPOSITE
POINTS OF THE EQUIPMENT, AND EXTEND EACH CONNECTION INDEPENDENTLY TO
DIFFERENT SEGMENTS OF THE GROUNDING SYSTEM.
8. INTERCONNECT ALL AIR TERMINALS AND SHALL FORM A TWO-WAY PATH FROM
EACH AIR TERMINAL HORIZONTALLY OR DOWNWARD TO CONNECTIONS WIT
GROUND TERMINALS.
9. FASTEN ALL LIGHTNING PROTECTION CONDUCTORS NOT MORE THAN 3'-0"
MAXIMUM SPACING.
10. DRIVE GROUND RODS SO THAT THE TOP OF THE GROUND RODS IS TO A MINIMUM
DEPTH OF 12" BELOW GRADE AND 2'-0" FROM FOUNDATION WALL.
11. MAKE CONNECTORS TO GROUND LOOP CONDUCTOR AT A POINT NOT LESS THAN
24" BELOW GRADE AND 2'-0" FROM FOUNDATION WALL.
12. PLACE THE AIR TERMINALS AT ALL UNPROTECTED OUTSIDE CORNERS AND 20'-0"
MAXIMUM SPACING AROUND THE ROOF PERIMETER OR RIDGE AND WITHIN 2'-0"
OF OUTSIDE EDGE.
13. PROVIDE ALL BURIED GROUND CABLES WITH A MINIMUM OF 18" OF EARTH COVER.
14. CLEAN BARE CABLE AT ALL CONNECTIONS TO A BRIGHT SURFACE, MAKE
CONNECTIONS ONLY WHEN THOROUGHLY DRY.
15. AFTER COMPLETION OF THE GROUND GRID, MEASURE AND RECORD THE
RESISTANCE TO EARTH. MEASUREMENTS SHALL BE MADE AS PER IEEE STD. 81. THE
RESISTANCE SHALL BE 5 OHMS OR LESS.
16. DO NOT INSTALL BARE COPPER LIGHTNING PROTECTION MATERIALS ON ALUMINUM
ROOF OR SIDING OR OTHER ALUMINUM SURFACES AND VISA VERSA, DO NOT
INSTALL ALUMINUM LIGHTNING PROTECTION MATERIALS ON COPPER ROOF OR
SIDING OR OTHER COPPER SURFACES.
17. INSTALL THE LIGHTNING PROTECTION SYSTEM IN A NEAT AND INCONSPICUOUS
MANNER SO THAT ALL COMPONENTS WILL BLEND IN WITH THE APPEARANCE OF
THE BUILDING.
18. ACTUAL JOB SITE CONDITIONS MAY NECESSITATE SLIGHT ALTERATIONS IN AIR
TERMINAL AND GROUND ROD LOCATIONS.
19. THE PLAN AND LAYOUT SHOWN FOR THESE SYSTEMS ARE SCHEMATIC AND ARE
INTENDED TO SHOW BASIC SYSTEM LAYOUT. VERIFY DIMENSIONS AND SITE
CONDITIONS AND PROVIDE SYSTEMS THAT COMPLY TO CODE REQUIREMENTS.
20. INSTALL DOWN CONDUCTORS FOR GROUNDING AND LIGHTNING PROTECTIONS IN
RIGID CONDUITS 8' FROM GROUND UP AND EXPOSED, MOUNTED ON WALL.
21. SUBMIT A SIGNED AND SEALED LIGHTNING PROTECTION SUBMITTAL DRAWING
THAT MEETS OR EXCEEDS THE REQUIREMENTS HEREIN, FOR OWNER'S APPROVAL
BEFORE CONSTRUCTION.
0 2' 4' 8' 12'
1 ADMINISTRATION BUILDING - ROOF PLAN
1/4" = 1'-0"2 MAINTENANCE BUILDING - ROOF PLAN
1/4" = 1'-0"
A
EJ-201
C
EJ-201
D
EJ-201
E
EJ-201
F
EJ-201
E
EJ-201
D
EJ-201
F
EJ-201
A
EJ-201
C
EJ-201
#4/0 B.C. STRANDED GROUND
GRID
24" MIN.
CONNECT GROUND ROD TO GROUND GRID
WITH EXOTHERMIC WELD
FINISHED GRADE
12" MIN.
GROUND
GAW910-TEST WELL
GROUND ROD CLAMP
CLASS II COPPER GROUNDING CONDUCTOR
GROUND ROD
3/4" DIA. x 10' LONG COPPER CLAD ROUND
GROUND ROD
EXOTHERMIC WELD
CONNECTION TO COUNTERPOISE
#4/0 AWG BARE CLASS II COPPER
CONDUCTOR 30" BELOW FINISHED GRADE
LIGHTNING PROTECTION
DETAILS
EJ-201
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
FINAL CONSTRUCTION DOCUMENTS
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2019, Walker Federal Serivces, LLC
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
824IC3005
HU UB
May 22, 2020
05/22/2020
ADHESIVE BASE
CLASS II CONDUCTOR
STRUCTURE
COPING
CABLE FASTENER
GROUNDING SYSTEM
GROUND ROD
GROUND ROD CLAMP
BRONZE BONDING PLATE
CLASS II CONDUCTOR
SURFACE
WELDED BASE BRONZE
BONDING PLATE
CLASS II
AIR TERMINAL
CLASS II COPPER CONDUCTOR
A AIR TERMINAL BONDED TO STRUCTURE
NONE
GENERAL NOTES
1. INTERCONNECT THE TELEPHONE AND ELECTRICAL SERVICE ENTRANCE GROUNDS TO
ONE LIGHTNING PROTECTION GROUND OR WATER PIPE.
2. GROUND ALL ELECTRICAL EQUIPMENT, ENCLOSURE, FRAMES AND STRUCTURES.
3. INTERCONNECT THE METAL BODIES OF INDUCTANCE LOCATED ABOUT THE ROOF
SUCH AS METAL FLASHING, GRAVEL STOPS, ROOF DRAINS, SOIL PIPE VENTS,
INSTALLATION VENTS, LOUVERS AND DOOR FRAMES SITUATED WITHIN 6'-0" OF A
LIGHTNING CONDUCTOR OR BONDED METAL BODY TO THE LIGHTNING CONDUCTOR
SYSTEM.
4. MAKE ALL UNDERGROUND OR EMBEDDED GROUNDING CONNECTIONS BY
EXOTHERMIC FUSION WELDING PROCESS, UON.
5. NO BENDS OF A CONDUCTOR SHALL FORM A FINAL INCLUDED ANGLE OF LESS THAN
90 DEGREES NOR SHALL HAVE A RADIUS OF BEND LESS THAN 8".
6. WHERE DOUBLE CONNECTIONS ARE REQUIRED, ATTACH AT DIAGONALLY OPPOSITE
POINTS OF THE EQUIPMENT, AND EXTEND EACH CONNECTION INDEPENDENTLY TO
DIFFERENT SEGMENTS OF THE GROUNDING SYSTEM.
7. INTERCONNECT ALL AIR TERMINALS AND SHALL FORM A TWO-WAY PATH FROM
EACH AIR TERMINAL HORIZONTALLY OR DOWNWARD TO CONNECTIONS WIT
GROUND TERMINALS.
8. FASTEN ALL LIGHTNING PROTECTION CONDUCTORS NOT MORE THAN 3'-0"
MAXIMUM SPACING.
9. DRIVE GROUND RODS SO THAT THE TOP OF THE GROUND RODS IS TO A MINIMUM
DEPTH OF 12" BELOW GRADE AND 2'-0" FROM FOUNDATION WALL.
10. MAKE CONNECTORS TO GROUND LOOP CONDUCTOR AT A POINT NOT LESS THAN
24" BELOW GRADE AND 2'-0" FROM FOUNDATION WALL.
11. PLACE THE AIR TERMINALS AT ALL UNPROTECTED OUTSIDE CORNERS AND 20'-0"
MAXIMUM SPACING AROUND THE ROOF PERIMETER OR RIDGE AND WITHIN 2'-0"
OF OUTSIDE EDGE.
12. PROVIDE ALL BURIED GROUND CABLES WITH A MINIMUM OF 18" OF EARTH COVER.
13. CLEAN BARE CABLE AT ALL CONNECTIONS TO A BRIGHT SURFACE, MAKE
CONNECTIONS ONLY WHEN THOROUGHLY DRY.
14. AFTER COMPLETION OF THE GROUND GRID, MEASURE AND RECORD THE
RESISTANCE TO EARTH. MEASUREMENTS SHALL BE MADE AS PER IEEE STD. 81. THE
RESISTANCE SHALL BE 5 OHMS OR LESS.
15. DO NOT INSTALL BARE COPPER LIGHTNING PROTECTION MATERIALS ON ALUMINUM
ROOF OR SIDING OR OTHER ALUMINUM SURFACES AND VISA VERSA, DO NOT
INSTALL ALUMINUM LIGHTNING PROTECTION MATERIALS ON COPPER ROOF OR
SIDING OR OTHER COPPER SURFACES.
16. INSTALL THE LIGHTNING PROTECTION SYSTEM IN A NEAT AND INCONSPICUOUS
MANNER SO THAT ALL COMPONENTS WILL BLEND IN WITH THE APPEARANCE OF
THE BUILDING.
17. ACTUAL JOB SITE CONDITIONS MAY NECESSITATE SLIGHT ALTERATIONS IN AIR
TERMINAL AND GROUND ROD LOCATIONS.
18. THE PLAN AND LAYOUT SHOWN FOR THESE SYSTEMS ARE SCHEMATIC AND ARE
INTENDED TO SHOW BASIC SYSTEM LAYOUT. VERIFY DIMENSIONS AND SITE
CONDITIONS AND PROVIDE SYSTEMS THAT COMPLY TO CODE REQUIREMENTS.
19. INSTALL DOWN CONDUCTORS FOR GROUNDING AND LIGHTNING PROTECTIONS IN
RIGID CONDUITS 8' FROM GROUND UP AND EXPOSED, MOUNTED ON WALL.
20. SUBMIT A SIGNED AND SEALED LIGHTNING PROTECTION SUBMITTAL DRAWING
THAT MEETS OR EXCEEDS THE REQUIREMENTS HEREIN, FOR OWNER'S APPROVAL
BEFORE CONSTRUCTION.
C GROUDING ROD BONDED TO EQUIPMENT
NONEE GROUNDING TEST WELL
NONE
B GROUNDING ROD BONDED TO STRUCTURE
NONED GROUDING ROD DETAIL
NONEF GROUNDING "T" JOINT CONNECTION DETAIL
NONE
SYMBOLS ABBREVIATIONS
SECURITY ACCESS, VIDEO CAMERA
CCTV WARNING SIGNAGE
AFF
ANSI
ASME
ASTM
BICSI
EIA
FCC
ISSS
ISO
NEC
NEMA
NESC
NFPA
OSHA
POE
RUS
SMPTE
TIA
UL
UON
ABOVE FINISHED FLOOR
AMERICAN NATIONAL STANDARDS INSTITUTE
AMERICAN SOCIETY OF MECHANICAL ENGINEERS
AMERICAN SOCIETY FOR TESTING MATERIALS
BUILDING INDUSTRY CONSULTING SERVICES INTERNATIONAL
ELECTRONICS INDUSTRY ASSOCIATION
FEDERAL COMMUNICATIONS COMMISSION
INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS
INTERNATIONAL STANDARDS ORGANIZATION
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION
NATIONAL ELECTRICAL SAFETY CODE
NATIONAL FIRE PROTECTION ASSOCIATION
OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
POWER OVER ETHERNET
RURAL UTILITY SERVICE (FORMERLY AREA)
SOCIETY OF MOTION PICTURE AND TELEVISION ENGINEERS
TELECOMMUNICATIONS INDUSTRY ASSOCIATION
UNDERWRITER'S LABORATORIES, INC.
UNLESS OTHERWISE NOTED
SECURITY GENERAL NOTES
1. ALL CABLE PATHWAYS ARE DESIGNED WITH A MAXIMUM 40 PERCENT FILL RATIO UNLESS
OTHERWISE NOTED. FILL REQUIREMENTS MAY ALTER FROM INITIAL DESIGN DUE TO COR'S
REQUIREMENTS DURING INSTALLATION.
2. ALL CABLE PATHWAYS SHALL BE FREE FROM PROJECTIONS AND ROUGH OR SHARP EDGES
THROUGHOUT THE ENTIRE PATH. ALL POINTS OR EDGES THAT CABLING MUST PASS, AND
MAY BE SUBJECT TO INJURY OR WEAR, SHALL BE ROUNDED, PADDED, OR BUSHED.
3. THE SECURITY DRAWINGS INDICATE THE GENERAL LOCATION OF EQUIPMENT, CABLE
PATHWAYS, AND OUTLETS. ALTHOUGH THE DRAWINGS DO NOT NECESSARILY DICTATE THE
ACTUAL ROUTES OF CABLE TRAYS AND CONDUITS, LOCATION OF EQUIPMENT AND OUTLETS,
AND OTHER SUPPORTING ITEMS. FOLLOW THE DESIGN IN THIS DOCUMENTS AS CLOSELY AS
POSSIBLE. COORDINATE TO THE NEAREST INSTALLATION OF SECURITY ITEMS WITH THOSE OF
ALL OTHER TRADES.
4. ALL BLOCKS, PANELS AND CABLE SHALL BE ASSIGNED, LABELED AND RECORDED BY THE
INSTALLING CABLE CONTRACTOR, AND DELIVERED TO THE ENGINEER.
5. SEE NOTES ON INDIVIDUAL DRAWINGS FOR CROSS REFERENCE TO PERTINENT DETAILS,
SECTIONS, ETC. SHOWN ON OTHER DRAWINGS IN THIS DRAWING SET.
6. SCALES NOTED ON THE SECURITY DRAWING ARE FOR GENERAL INFORMATION AND USED
FOR REFERENCE ONLY.
7. ALL MOUNTING HEIGHTS SHOWN ARE MEASURED FROM FINISHED FLOOR TO BOTTOM OF
MOUNTED EQUIPMENT UNLESS OTHERWISE NOTED.
8. FIRE STOP ALL STRUCTURE PENETRATIONS WITH FIRE STOPPING MATERIAL EQUAL TO OR
GREATER THAN THAT OF PENETRATED STRUCTURE. INSTALL FIRE STOPPING MATERIAL AFTER
COMPLETE INSTALLATION OF CABLING. USE ONLY LISTED FIRE STOPPING MATERIAL IN
ACCORDANCE WITH UL, AND OTHER AUTHORITIES HAVING JURISDICTION.
9. SECURITY ROOMS SHALL NOT BE USED AS STORAGE SPACE BY ANY CONTRACTOR EXCLUDING
THE INSTALLING CONTRACTOR FOR THE SECURITY SYSTEMS.
10. ALL NEW SECURITY ROOMS/CLOSETS WILL HAVE 1-HOUR FIRE RATED WALLS. SEE
ARCHITECTURAL DRAWINGS FOR DETAILS.
11. NOT ALL HARDWARE FOR INSTALLATION IS IDENTIFIED/SHOWN. THE SECURITY CONTRACTOR
IS RESPONSIBLE FOR ALL MOUNTING HARDWARE REQUIRED FOR A COMPLETE AND
PROPERLY OPERATING INSTALLATION.
12. NOT ALL ITEMS, COMPONENTS AND SYSTEMS SPECIFIED IN THIS DRAWING SET OR THE
SPECIFICATIONS ARE DETAILED. PROVIDE MANUFACTURER'S SPECIFICATIONS AND DETAIL
SHEETS IN THE PRE-CONSTRUCTION SUBMITTALS FOR SELECTION PER THE SPECIFICATIONS.
13. INSTALL COMPONENTS OR SYSTEMS PER THE MANUFACTURE'S INSTALLATION
INSTRUCTIONS OR SPECIFICATIONS.
14. ALL CABLE SHALL COMPLY WITH THE SPECIFICATIONS AND SHALL BE SUITABLE AND LISTED
FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED.
15. ALL CONDUIT RUNS SHALL FOLLOW BICSI STANDARDS FOR BENDS, FILL AND JUNCTION BOX
PLACEMENT. NO CONDUIT RUNS SHALL HAVE GREATER THAN 180 DEGREES OF BEND
WITHOUT A PROPERLY SIZED AND PLACED BOX.
16. ALL CONDUIT RUNS AND CABLE TRAY SHOWN ARE DIAGRAMMATICAL. REPORT ANY MAJOR
DEVIATION TO CONSTRUCTION MANAGER FOR APPROVAL.
17. ALL CONDUITS FROM BELOW SHALL STUB UP 4" AFF.
18. COORDINATE FINAL SYSTEMS, EQUIPMENT LAYOUT AND CONDUIT ROUTING AS SHOWN ON
DRAWING WITH SITE CONDITIONS.
19. ENSURE PROPER SEPARATION OF CLASS 1, CLASS 2, AND CLASS 3 CIRCUITS PER NEC 725-54.
20. VERIFY THE SIZE OF ALL CONDUCTORS, CONDUIT,L AND JUNCTION BOXES (40% MAXIMUM
FILL). INSTALLATION SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE (NEC)
AND ALL LOCAL CODES HAVING JURISDICTION.
21. DO NOT INSTALL LOW VOLTAGE VOICE AND DATA CABLING IN THE SAME CONDUITS AS 120
VAC POWER CABLES.
22. PROMPTLY NOTIFY COR PRIOR TO INSTALLATION OF WORK IF ANY MOUNTING LOCATIONS
NOTED ON THE DRAWINGS ARE OBSTRUCTED AND/OR IF ANY CONFLICTS OR PROBLEMS ARE
DISCOVERED.
23. PROVIDE AND INSTALL EQUIPMENT AND HARDWARE IN ORDER TO MEET THE INTENT OF THE
DESIGN AND TO PROVIDE GOVERNMENT WITH A COMPLETE AND FULLY OPERATIONAL
CABLING SYSTEM AS SPECIFIED. PROMPTLY ADDRESS ANY QUESTIONS REGARDING THE
INTENT OF THE DESIGN TO THE COR.
24. PROVIDE A SINGLE GANG BOX WITH A CONDUIT TO THE NEAREST ACCESSIBLE CEILING FOR
ANY DEVICE SHOWN ON THESE DRAWINGS THAT IS LOCATED IN AN OPEN OR HARD CEILING
SPACE.
25. ALL CABLES CEILING SHALL BE PLENUM RATED.
1. COORDINATE EXACT REQUIREMENTS FOR INCOMING SERVICE OF LOCAL UTILITIES FOR POWER AND
TELEPHONE, PAY ALL FEES, AND INSTALL A COMPLETE AND FUNCTIONAL SYSTEM.
2. COORDINATE INSTALLATION OF TELEPHONE SYSTEM INCLUDING TELEPHONE WIRING AND TELEPHONE
OUTLETS WITH THE GOVERNMENT/ENGINEER.
3. REFER TO BASE BUILDING DRAWINGS FOR LOCATION OF UTILITY SERVICE JUNCTION BOX.
COORDINATION WITH TELEPHONE COMPANIES
SECURITY SYMBOLS,
ABBREVIATIONS AND
GENERAL NOTES
EY-001
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
FINAL CONSTRUCTION DOCUMENTS
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2019, Walker Federal Serivces, LLC
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
824IC3005
HU UB
May 22, 2020
05/22/2020
G
AS
G
AS
GAS
GAS
GAS
G
AS
W
W
W
ST
ST
ST
ST
ST
ST
ST
W
W
T T
W
W W
GAS
ST
ST
ST ST ST ST ST ST ST ST ST
ST ST ST
ST
ST
ST
ST
ST
ST
ST
GAS GAS GAS GAS GAS GAS
W W W W
ST ST ST
RE
F
SAN
ST
ST
T T
ST
ST
SAN
W W
C C
G
AS
G
AS
GAS
GAS
GAS
G
AS
W
W
W
ST
ST
ST
ST
ST
ST
ST
W
W
T T
W
W W
GAS
ST
ST
ST ST ST ST ST ST ST ST ST
ST ST ST
ST
ST
ST
ST
ST
ST
ST
GAS GAS GAS GAS GAS GAS
W W W W
ST ST ST
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
FINAL CONSTRUCTION DOCUMENTS
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2019, Walker Federal Serivces, LLC
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
824IC3005
HU UB
May 22, 2020
05/22/2020
0 10 20 40 60
SITE SECURITY PLAN
EY-101
GENERAL NOTES
1. FOR SECURITY SYMBOLS, ABBREVIATIONS AND GENERAL NOTES, SEE
DRAWING EY-001.
2. FOR SECURITY DETAILS, SEE DRAWING EY-201.
3. COORDINATE WORK WITH THAT OF ELECTRICAL CONTRACTOR FOR
ELECTRICAL INSTALLATION SUPPORT.
4. CAMERA LOCATIONS ARE APPROXIMATE. MAKE MINOR ADJUSTMENTS
FOR INCREASED EFFECTIVENESS, AS APPROVED BY THE COR.
5. CCTV SIGNAGE IS SHOWN SCHEMATICALLY. FINAL LOCATIONS SHALL BE
APPROVED BY COR.
6. REFER TO SPECIFICATIONS FOR PROTECTION OF EXISTING TREES DURING
EXCAVATION AND OTHER ADJACENT WORK.
7. EXERCISE EXTREME CAUTION WHEN WORKING ADJACENT TO HEADSTONES.
CONDUCT ALL EXCAVATION ADJACENT TO HEADSTONES SOLELY IN THE
PRESENCE AND UNDER THE DIRECTION OF THE COR. SHOULD ANY
EVIDENCE OF INTERMENTS BE ENCOUNTERED AT ANY TIME, IMMEDIATELY
STOP WORK, NOTIFY COR AND CEMETERY DIRECTOR, AND AWAIT COR'S
DIRECTION.
KEY NOTES
PROVIDE NEW NETWORK VIDEO RECORDER (NVR) AND NETWORK SWITCH INSIDE
THE WALL MOUNTED RACK IN IT CLOSET (105A) - ADMINISTRATION BUILDING.
FOR ROUTE OF CABLES, SEE ELECTRICAL SITE PLAN.
SECURITY ACCESS, VIDEO CAMERA
CCTV WARNING SIGNAGE
LEGEND
CCTV #1
CCTV #3
CAMERA
MOUNTED ON
WALL (TYP.)
TEMPORARY
OFFICE
TRAILER
ADMINISTRATION
BUILDING
MAINTENANCE
BUILDING
STORAGE
BUILDING
CCTV #5CCTV #4
EXTERIOR
PULLBOX (TYP.)
CCTV #2
NETWORK VIDEO
RECORDER
CCTV
SIGNAGE
(TYP.)
UNDERGROUND
CABLES FOR
CAMERA
EXISTING
TELECOMMUNICATION
LINE
TYPICAL EXTERIOR CCTV CAMERAS
ROUTER
TV DISPLAY
PC WORK STATION
BY NCA
REMOTE LAPTOP
BY NCA
INTERNET
IT ROOM (105A)
16 PORT NETWORK
VIDEO RECORDER
(NVR) + POE SWITCH
SECURITY DETAILS
EY-201
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
FINAL CONSTRUCTION DOCUMENTS
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2019, Walker Federal Serivces, LLC
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
824IC3005
HU UB
May 22, 2020
05/22/2020
C SECURITY SYSTEM BLOCK DIAGRAM
NONE
SYSTEM QUANTITY MODEL NUMBERMOUNTING MANUFACTURER REMARKS
A SECURITY SYSTEM SCHEDULE
NONE
WALL05CCTV #1 TO CCTV#5
OUTDOOR BULLET CAMERA.
PROVIDE WITH JUNCTION BOX (H4 - BO - JBOX1) AND
ALUMINUM CORNER MOUNTING BRACKET (H4 - MT - CRNR1)
AVIGILON 8.0C - H5A - BO1 - IR
IT RACK01
NETWORK VIDEO RECORDER
(NVR) VMA - AS3 - 16P12
IT RACK01UPS SMC1500 - 2UC
16 PORT 12 TB HD VIDEO APPLIANCE PRO FOR
VIDEO SURVEILLANCE SYSTEM
APC BY
SCHNEIDER ELECTRIC
AVIGILON
1500 VA, 120V POWER
23.62" 32.99"
.82
D IT RACK DETAILS
NONE
FRONT VIEW SIDE VIEW 3D VIEW
SYSTEM MODEL / SKU NUMBERMANUFACTURER
IT RACK_ADMINISTRATION BUILDING NAVEPOINT 00406143
TYPE
24U - MID DEPTH CABINETS
NOTE:
PROVIDE EQUIPMENT/DEVICE TO MEET THE SPECIFICATIONS OF NAMED MANUFACTURER OR APPROVED EQUAL.
ALL PRODUCTS, EQUIPMENT AND DEVICES PROVIDED UNDER THIS PROJECT SHALL CONFORM TO "BUY AMERICAN ACT".
NOTE:
PROVIDE EQUIPMENT/DEVICE TO MEET THE SPECIFICATIONS OF NAMED MANUFACTURER OR APPROVED EQUAL.
ALL PRODUCTS, EQUIPMENT AND DEVICES PROVIDED UNDER THIS PROJECT SHALL CONFORM TO "BUY AMERICAN ACT".
23.62" W X 32.99" D X 48.82" H
DIMENSIONS
IT CABINET MUST BE BOLTED TO THE FLOOR AND
USE TO MOUNT ONLY IT DEVICES.
REMARKS
B WALL MOUNTED RACK DETAILS
NONE
SYSTEM MODEL / SKU NUMBERMANUFACTURER
WALL MOUNTED RACK_ADMINISTRATION BUILDING NAVEPOINT 00406203
TYPE
9U-WALL MOUNT
NOTE:
PROVIDE EQUIPMENT/DEVICE TO MEET THE SPECIFICATIONS OF NAMED MANUFACTURER OR APPROVED EQUAL.
ALL PRODUCTS, EQUIPMENT AND DEVICES PROVIDED UNDER THIS PROJECT SHALL CONFORM TO "BUY AMERICAN ACT".
23.50" W X 18.00" D X 20.00" H
DIMENSIONS
USE TO MOUNT
TELECOM AND SECURITY DEVICES.
REMARKS
WALL MOUNTED RACK_TRAILER NAVEPOINT 004062039U-WALL MOUNT 23.50" W X 18.00" D X 20.00" H USE TO MOUNT
TELECOM AND IT DEVICES.
DS
DS
DS
RA
M
P
DN
DN
REF
CLOSET
104A
KITCHEN
UTILITY RM
RESTROOM
LOBBY
OFFICE
RESTROOM
OFFICE
OFFICE
HALL
CLOSET
108A
CLOSET
109A
CLOSET
110A
IT CLOSET
105A
CLOSET
102A
ENT. PORCH
104B
PORCH
109B
DN
DN
CLOSET
107A
LOUNGE
SD
SD SD
SD
SD
PNL B-26
SD
DS DS
DS DS
CLOSET
102A
RESTROOM
GARAGE
HAZMAT STOR
RESTROOM
102 CLOSET
101A
DS
SD SD
PNL A-22
DS
DS
SD
PNL C-5
DS DS DS DS DS
SD
SD
1 ADMINISTRATION BUILDING - FLOOR PLAN
1/4" = 1'-0"
FIRE ALARM PLANS
FA-101
0 2' 4' 8' 12'
GENERAL NOTES
1. WHERE CONDUIT AND CABLE PENETRATE FIRE RATED FLOORS AND WALLS,
PROVIDE U.L. LISTED FIRE STOPPING SYSTEM FOR EACH PENETRATION. GROUP
CABLES/CONDUITS TOGETHER TO REDUCE QUANTITY OF PENETRATIONS
WHEREVER POSSIBLE.
2. ALL EQUIPMENT SHALL BE NEW AND BEAR THE APPROPRIATE U.L. LISTING OR
CLASSIFICATION MARK. INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH
THE U.L. LISTING OR CLASSIFICATION.
3. COORDINATE WITH ARCHITECTURAL, STRUCTURAL AND MECHANICAL
DRAWINGS. SUCH COORDINATION SHALL OCCUR PRIOR TO ANY ROUGH-IN
AND PRIOR TO PROCUREMENT OF ANY MATERIAL(S).
KEY NOTES
CONTRACTOR SHALL PROVIDE NEW BATTERY BACKED - UP, INTERCONNECTED,
HARDWIRED AND TAMPER RESISTANT SMOKE ALARM, FIRST ALERT MODEL #SA520,
OR APPROVED EQUAL, AS SHOWN.
TRAILER SUPPLIER SHALL PROVIDE NEW BATTERY BACKED - UP, INTERCONNECTED,
HARDWIRED AND TAMPER RESISTANT SMOKE ALARM, FIRST ALERT MODEL #SA520,
OR APPROVED EQUAL, AS SHOWN.
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
FINAL CONSTRUCTION DOCUMENTS
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2019, Walker Federal Serivces, LLC
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
824IC3005
HU UB
May 22, 2020
05/22/2020
SMOKE ALARM
LEGEND
3 MAINTENANCE BUILDING - FLOOR PLAN
1/4" = 1'-0"
SD
1 (TYP.)
4 STORAGE BUILDING - FLOOR PLAN
1/4" = 1'-0" 2 TEMPORARY OFFICE TRAILER - FLOOR PLAN
3" = 1'-0"
(TYP.)
GENERAL ABBREVIATIONS
MANUAL VALVE
PIPE UNION
MECHANICAL SYMBOLS LEGEND
END CAP
PIPE RISE
PIPE DROP
TOP TAKE-OFF
BOTTOM TAKE-OFF
PIPE BREAK
AAV
PT
MANUAL VALVE WITH MEMORY STOP (BALANCING)
CAPPED VALVE WITH HOSE BIBB AND CHAIN
CHECK VALVE
Y-STRAINER
BASKET STRAINER
AUTOMATIC VALVE, 2-POSITION ACTUATOR
AUTOMATIC VALVE, MODULATING ACTUATOR
3-WAY VALVE, 2-POSITION ACTUATOR
3-WAY VALVE, MODULATING ACTUATOR
PRESSURE GAGE WITH GAGE CLOCK
TEMPERATURE SENSOR
PRESSURE / TEMPERATURE WELL
AUTOMATIC AIR VENT WITH ISOLATION VALVE
MANUAL AIR VENTMAV
FLEXIBLE CONNECTION
PIPE GUIDE
ANCHOR
UP
DN
DIRECTION OF FLOW IN PIPE
PITCH PIPE UP IN DIRECTION OF FLOW
PITCH PIPE DOWN IN DIRECTION OF FLOW
REFRIGERANT PIPING LINE SET
MECHANCIAL EQUIPMENT - NEW
A
A AMPERE
AC AIR CONDITIONING
ACV AUTOMATIC CONTROL VALVE
ACD AUTOMATIC CONTROL DAMPER
AD ACCESS DOOR
AF AIR FILTER
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ALM ALARM
AP ACCESS PANEL
ARCH ARCHITECT
AS AIR SEPARATOR
ATC AUTOMATIC TEMPERATURE CONTROLS
ATV ATMOSPHERIC VENT
AAV AUTOMATIC AIR VENT
AVS AIR VOLUME STATION
B
BHP BREAK HORSE POWER
BOD BOTTOM ELEVATION OF DUCT
BOP BOTTOM ELEVATION OF PIPE
BRD BAROMETRIC DAMPER
BWV BACK WATER VALVE
C
CC COOLING COIL
CFM CUBIC FEET PER MINUTE
CLG CEILING
CO CLEAN-OUT
CD CONDENSATE DRAIN
CRAC COMPUTER ROOM AIR CONDITIONING UNIT
CV CONSTANT VOLUME
D
D DRAIN
DC DUST COLLECTION DUCTWORK
DAT DISCHARGE AIR TEMPERATURE
DBT DRY BULB TEMPERATURE
DDC DIRECT DIGITAL CONTROL
DIA DIAMETER
DIM DIMENSION
DN DOWN
DP DIFFERENTIAL PRESSURE
DX DIRECT EXPANSION
E
(E) EXISTING
EA EACH
EAD EXHAUST AIR DAMPER
EAT ENTERING AIR TEMPERATURE
EF EXHAUST FAN
EFF EFFICIENCY
ELEC ELECTRICAL
ER EXHAUST REGISTER
ES END SWITCH
ESP EXTERNAL STATIC PRESSURE
ET EXPANSION TANK
EWT ENTERING WATER TEMPERATURE
F
F FAN
FA FREE AREA
FCU FAN COIL UNIT
FD FIRE DAMPER
FMT FLOW METER/TRANSMITTER
FPB FAN POWERED BOX (TERMINAL UNIT)
FPM FEET PER MINUTE
FSD FIRE/SMOKE DAMPER
FT FEET
FZ FREEZE STAT
G
G GAS
GR GLYCOL RETURN
GS GLYCOL SUPPLY
H
H HEIGHT
HB HOSE BIBB CONNECTION WITH CHAINED CAP
HC HEATING COIL
HHWR HEATING HOT WATER RETURN
HHWS HEATING HOT WATER SUPPLY
HOA HAND-OFF-AUTOMATIC SWITCH
HP HORSE POWER
HP HEAT PUMP
HV HEATING & VENTILATING UNIT
HW HOT WATER
HWR HOT WATER RETURN (DOMESTIC)
HWS HOT WATER SUPPLY (DOMESTIC)
HVAC HEATING VENTILATION AIR CONDITIONING
HX HEAT EXCHANGER
HZ HERTZ
I
IN INCHES
INWC INCHES OF WATER COLUMN
K
KW KILOWATTS
L
LAT LEAVING AIR TEMPERATURE
LD LINEAR DIFFUSER
LF LINEAR FEET
LPR LOW PRESSURE CONDENSATE RETURN
LPS LOW PRESSURE STEAM SUPPLY
LSPS LOW STATIC PRESSURE SWITCH
LWT LEAVING WATER TEMPERATURE
M
MAV MANUAL AIR VENT
MCC MOTOR CONTROL CENTER
MECH MECHANICAL
MIN MINIMUM
MPR MEDIUM PRESSURE CONDENSATE RETURN
MPS MEDIUM PRESSURE STEAM SUPPLY
N
N/A NOT APPLICABLE
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NUM NUMBER
NTS NOT TO SCALE
O
OA OUTSIDE AIR
OAD OUTSIDE AIR DAMPER
OAT OUTSIDE AIR TEMPERATURE
OCC OCCUPIED
OED OPEN END DUCT
P
P PUMP
PC PUMPED CONDENSATE
PD PRESSURE DROP
PLBG PLUMBING
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
R
RA RETURN AIR
RAD RETURN AIR DAMPER
RAT RETURN AIR TEMPERATURE
RD RETURN DIFFUSER
RET RETURN
REQ REQUIRED
RF RETURN FAN
RG RETURN GRILLE
RH RELATIVE HUMIDITY
RI RUN INDICATOR
RL REFRIGERANT LIQUID
RPM REVOLUTIONS PER MINUTE
RR RETURN REGISTER
RS REFRIGERANT SUCTION
RTU ROOFTOP UNIT
S
SA SUPPLY AIR
SA SOUND ATTENUATOR
SAD SUPPLY AIR DAMPER
SD SUPPLY DIFFUSER
SDET SMOKE DETECTOR
SF SUPPLY FAN
SP STATIC PRESSURE SENSOR
SQFT SQUARE FEET
SR SUPPLY REGISTER
S/S START/STOP
SUP SUPPLY
T
T TEMPERATURE SENSOR
TEMP TEMPERATURE
TF TRANSFER FAN
TG TRANSFER GRILLE
TOD TOP ELEVATION OF DUCT
TOP TOP ELEVATION OF PIPE
TYP TYPICAL
U
UH UNIT HEATER
UNOCC UNOCCUPIED
UNO UNLESS NOTE OTHERWISE
V
V VENT
VAV VARIABLE AIR VOLUME TERMINAL UNIT
VD VOLUME DAMPER
VFD VARIABLE FREQUENCY DRIVE
VS VIBRATION SWITCH
W
W WIDTH
WBT WET BULB TEMPERATURE
WMS WIRE MESH SCREEN
WIC WALK-IN COOLER
GENERAL ABBREVIATIONS (CONT.)
CONNECT NEW TO EXISTING
LIMIT OF DEMOLITION
KEY NOTE SYMBOL
CONDENSATE PIPE
FS
D
CD
R
DATA
TAG
DATA
TAG
1. SYSTEM UTILIZES THE REDUCED LIGHTING POWER DENSITY
OPTION TO COMPLY WITH THE ADDITIONAL EFFICIENCY
REQUIREMENTS OF IECC C406.
FS
D OR
1. GENERAL NOTES, SYMBOLS LIST AND DETAILS ARE APPLICABLE
TO ALL DRAWINGS WITHIN THIS SECTION.
2. COORDINATE WORK OF THIS SECTION WITH THAT OF OTHER
SECTIONS.
3. THIS SCOPE OF CONSTRUCTION WORK INCLUDES FURNISHING
LABOR, MATERIALS, EQUIPMENT AND PERFORMANCE OF ALL
OPERATIONS REQUIRED TO PROVIDE A COMPLETE,
FUNCTIONAL AND OPERATIONAL SYSTEM.
4. COORDINATE ROOF PENETRATIONS WITH WORK OF OTHER
SECTIONS AND WITH FLASHING REQUIREMENTS. PROVIDE
INFORMATION, HARDWARE, AND LABOR AS NECESSARY TO
COORDINATE ROOF CURBS REQUIRED FOR ROOF TOP
EQUIPMENT.
5. SUPPORT ALL EQUIPMENT, PIPING AND DUCTWORK FROM
BUILDING STRUCTURE TO PROVIDE A VIBRATION FREE
INSTALLATION. NOTIFY STRUCTURAL ENGINEER OF ALL
WEIGHTS AND METHODS OF SUPPORT.
6. ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH
NATIONAL ELECTRIC CODE.
7. ALL MATERIALS AND EQUIPMENT SHALL BE NEW, UNLESS
NOTED OTHERWISE.
8. THE CONTRACTOR SHALL MAKE CONNECTIONS TO EQUIPMENT
AND FIXTURES INSTALLED BY HIS WORKMEN AS WELL AS
EQUIPMENT AND FIXTURES FURNISHED BY OTHERS, PROVIDED
BY THE GOVERNMENT, OR OTHERWISE SPECIFIED ON THE
DESIGN DOCUMENTS.
9. THOUGH SOME OFFSETS & TRANSITIONS ARE SHOWN IN
PIPING & SHEET METAL TO HELP INDICATE THE PHYSICAL
RELATIONSHIP BETWEEN THEM, IT IS NOT THE INTENT OF THE
DRAWINGS TO SHOW ALL PIPING & SHEET METAL OFFSETS &
TRANSITIONS REQUIRED. THE CONTRACTOR SHALL FULLY
COORDINATE THE WORK WITHIN ITSELF & WITH THE WORK OF
ALL TRADES TO PROVIDE COMPLETE & OPERABLE SYSTEMS
WITHOUT INTERFERENCES.
10. THE DOCUMENTS CONTAIN INFORMATION RELATIVE TO
SYSTEM SETPOINTS (PRESSURE, FLOW, TEMPERATURE, ETC...)
THAT ARE PROVIDED FOR INFORMATIONAL PURPOSES ONLY.
THE TESTING ADJUSTING AND BALANCING CONTRACTOR IN
CONJUNCTION WITH THE AUTOMATIC TEMPERATURE
CONTROLS CONTRACTOR SHALL SET ACTUAL SETPOINTS.
11. MANUFACTURERS' MODEL NUMBERS ARE SPECIFIED ON
EQUIPMENT SCHEDULES SOLELY TO ESTABLISH STANDARDS OF
QUALITY FOR PERFORMANCE AND MATERIALS.
12. EQUIPMENT AND MATERIAL INSTALLATION SHALL ADHERE TO
MANUFACTURES' REQUIREMENTS AND RECOMMENDATIONS.
13. PROVIDE ACCESS PANELS TO SYSTEM COMPONENTS THAT ARE
CONCEALED AND REQUIRE PERIODIC SERVICE.
14. ALL EQUIPMENT, PIPING, INSULATION, ETC., INSTALLED IN
HVAC PLENUM SPACES SHALL MEET CODE REQUIREMENTS FOR
FLAME AND SMOKE PER UNDERWRITERS'S LABORATORY (UL).
15. PROVIDE WEATHERPROOF EXTERNAL JACKETING FOR ALL
DUCT AND PIPE INSULATION THAT IS EXPOSED TO THE
OUTDOORS.
16. PROVIDE VAPOR RETARDANT FOR ALL INSULATED PIPES AND
EQUIPMENT THAT ARE PART OF THE COOLING SYSTEM, OR
ARE INSTALLED OUTSIDE THE CONDITIONED SPACE.
1. ALL MECHANICAL WORK SHALL BE IN ACCORDANCE WITH THE
CURRENT INTERNATIONAL MECHANICAL CODE INCLUDING
LOCAL JURISDICTION SUPPLEMENTS AND AMENDMENTS. ALL
WORK SHALL BE EQUAL OR SUPERIOR TO THAT REQUIRED BY
RULES, CODES, ORDERS, REGULATIONS AND LAWS IMPOSED BY
AUTHORITY HAVING JURISDICTION. THE MORE STRINGENT OF
THE CODES SHALL GOVERN.
2. ALL RETURN AIR OPENINGS ABOVE CEILING SHALL BE PROVIDED
WITH A 1/4" MESH ALUMINUM SCREEN.
3. ALL DIMENSIONS SHOWN FOR DUCTWORK ARE NET INSIDE
DIMENSIONS.
4. ALL WALL MOUNTED DEVICES SUCH AS THERMOSTATS SHALL BE
MOUNTED AT 48" ABOVE FINISHED FLOOR U.N.O. BY
ARCHITECT.
5. ALL ROUND RUN OUTS TO DIFFUSERS SHALL BE THE SAME
NOMINAL SIZE AS THE SCHEDULED DIFFUSER NECK SIZE.
6. THOUGH SOME MANUAL VOLUME DAMPERS ARE SHOWN ON
THE DRAWINGS, IT IS NOT THE INTENT OF THE DRAWINGS TO
SHOW ALL MANUAL VOLUME DAMPERS IN SUPPLY, RETURN
AND EXHAUST DUCTWORK. PROVIDE MANUAL VOLUME
DAMPERS AT THE FOLLOWING LOCATIONS AS REQUIRED TO
REGULATE THE FLOW OF AIR FOR OF AIR FOR PROPER BALANCE
AND OPERATION OF THE DUCT SYSTEMS.
- BRANCH TAKEOFFS
- DUCT SPLITS (DUCT “Y’S” OR SIMILAR SPLIT FABRICATIONS).
7. PROVIDE ALL NECESSARY DUCT TRANSITIONS TO CONNECT
DUCTWORK SYSTEMS TO EQUIPMENT AND DIFFUSERS.
8. ALL JOINTS AND SEAMS OF AIR DUCTS, AIR-HANDLERS, AND
FILTER BOXES SHALL BE SEALED TO SMACNA SEAL CLASS A. ALL
DUCTWORK FOR THIS PROJECT IS LOW PRESSURE DUCT, 2" W.G.
PROVIDE DUCT SEALANT TO COMPLY WITH UL723 CLASS 1
TESTED, AND ASTM 572 AND C732, WITH VOC NOT MORE THAN
250 G/L.
9. ALL NEW DUCTWORK SHALL BE GALVANIZED SHEET METAL,
2" PRESSURE CLASS, WITH METAL GAUGE (THICKNESS)
AND SUPPORTS DETERMINED BY COMPLIANCE WITH
SMACNA GUIDELINES FOR 2" PRESSURE CLASS. DUCT MAY
BE SLIP/DRIVE OR FLANGED.
10. FLEXIBLE DUCTWORK MAY BE USED AS FOLLOWS: LOW
PRESSURE APPLICATION ONLY, UL LISTED CLASS 1,
DOUBLE LAMINATED POLYESTER OR COATED FIBERGLASS
CLOTH WITH HELICAL WIRE REINFORCEMENT; FACTORY
INSULATED.
11. ALL ELECTRICAL MOTORS SHALL MEET EPAct 1992 MINIMUM
EFFICIENCY REQUIREMENTS.
12. DAMPER LEAKAGE RATES SHALL NOT EXCEED 10 CFM/SF.
13. ALL NEW SUPPLY, RETURN, AND OUTSIDE AIR DUCTS SHALL
BE INSULATED TO A MINIMUM R-6.
14. SUPPLY AND RETURN EXTERIOR DUCTWORK &
DUCTWORK LOCATED IN THE ATTIC SHALL BE INSULATED
TO A MINIMUM OF R-8.
15. HVAC PIPING CARRYING FUILDS OF 105F OR BELOW 55F
SH…