S02 - 824IC3005 Bid Dwgs Woodlawn Bk07.pdf
PDF 11 MB Posted
- Solicitation number
- 36c78620b0009
About this file
This document provides details on a federal contract opportunity for facility renovations and improvements. The solicitation number is 36c78620b0009 and seeks bids for renovations at the Woodlawn and Bath National Cemeteries. The opportunity type is a solicitation issued by the Department of Veterans Affairs National Cemetery Administration. The description specifies that the contract involves facility renovations, improvements, and repairs at the Woodlawn-Bath National Cemetery. A PDF file of related bid drawings for the Woodlawn location is also provided. The response due date and anticipated award date are not stated.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ITEM MANUFACTURER MODEL SIZE FINISH COLOR OTHER
ACCESSIBLE PARKING
SIGN POST EMEDCO; 800-442-3633 FLEXPOST BOLLARD W/ 8' SIGN
POST
7"Ø x 102" HT; 15
8" x 96"
POST MFR'S STANDARD
BOLLARD: BLUE
REFLECTIVE TAPE:
WHITE
AGGREGATE
NJ GRAVEL & SAND; 732-410-7172
OR APP'D EQUAL A1: AGGREGATE 1" N/A NUTMEG CLEAN, WASHED
N/A A2: AASHTO #4 11
2" N/A N/A CRUSHED, WASHED
EDGING MID CITY STEEL; WESTPORT, MA;
774-319-5400
COMMERCIAL STEEL LANDSCAPE
EDGING
4" x 5" GALVANIZED N/A PROVIDE MFR'S 15" GALVANIZED STEEL
STAKES
FINIAL KING ARCHITECTURAL METALS
800-542-2379
F1: 45-3003-2 45 8" x 21
4"
CAST IRON N/A
F2: 45-3003-4 71 2" x 41
2"
FAUCET VALVE HAWS; 775-359-4712 6252EHLF 1
2" INLET MFR'S STANDARD N/A
FUEL TANK THE J. L. HOUSTON CO.; HOPKINS,
MO; 660-778-3393 REFER TO FUEL TANK COMPONENTS SCHEDULE, 2/LS-211
P1 - DETECTABLE
WARNING PLATE NEENAH FOUNDRY; 920-725-7000
4984-24B 24" x 24"
ECOBAKE N/A PROVIDE MFR'S STANDARD PROTECTIVE
PLASTIC SHEETINGP2 - DETECTABLE
WARNING PLATE 4984-30B 24" x 30"
SIGN POST BASE SAFETYSIGN.COM; 800-274-6271
SNAP'N SAFE SURFACE MOUNT
BREAKAWAY ANCHOR FOR
SQUARE POST
2" N/A N/A PROVIDE MFR'S STANDARD BASE
ANCHORS & CORNER BOLTS
SPILL KIT NEW PIG CORPORATION; TIPTON,
PA; 800-468-4647
KIT469; OIL-ONLY SPILL KIT IN
HIGH VISIBILITY MOBILE
CONTAINER
40 GALLON N/A N/A
SPILL KIT SIGN COMPLIANCE SIGNS; 800-578-1245 PORTRAIT SPILL KIT LABEL
CTSE-18520_YLW, REFLECTIVE 24" x 6" N/A MFR'S STANDARD ADHERE TO FENCE POST WHERE
INDICATED
TEMP. CEMETERY
OFFICE TRAILER WILLSCOT; 866-850-4288 FLEX 8' x 40' MFR'S STANDARD MFR'S STANDARD
PROVIDE CONFIGURATION SHOWN W;
TIE-DOWNS; PRE-WIRE UP TO (5) DATA
CONNECTIONS
VALVE BOX TYPE 1 RAINBIRD PVB PROFESSIONAL SERIES
STANDARD VALVE BOX 12" N/A BLACK PROVIDE MFR'S STANDARD MATCHING
GREEN DROP-IN LID
VALVE BOX TYPE 2 HIGHLINE PRODUCTS; 803-628-4381 HIGHLINE WATER ROADWAY
VALVE BOX MFR'S STANDARD N/A N/A
PROVIDE MFR'S 11" FLANGED CAST
IRON FRAME & CAST IRON "WATER"
COVER; PROVIDE MFR'S STANDARD
RISERS & EXTENSION AS NECESSARY TO
MEET FINISHED GRADE
X1 - PAINT
SHERWIN WILLIAMS; 800-524-5979
ACROLON ULTRA HIGH
PERFORMANCE POLYURETHANE N/A PAINT
SAFETY YELLOW PREP SURFACE, APPLY X3 PRIMER & 2
COATS DESIGNATED PAINTX2 - PAINT WHITE; MATCH EXISTING
X3 - PRIMER MACROPHOXY 646-100 FAST
CURE EPOXY PRIMER MILL WHITE
1 PRODUCT SCHEDULE
NOTES
1. THE ABOVE CONSTITUTES BASIS-OF-DESIGN SPECIFICATIONS. PROVIDE THE NAMED PRODUCTS OR EQUALS, AS APPROVED BY THE COR. FOR PRODUCTS PROPOSED OTHER THAN THOSE ABOVE, PROVIDE
DOCUMENTATION OF BOTH SPECIFIED AND PROPOSED PRODUCTS AS NECESSARY TO DEMONSTRATE A SIDE-BY-SIDE COMPARISON FOR COR'S CONSIDERATION.
2 FUEL TANK COMPONENTS SCHEDULE
QUANTITY MODEL DESCRIPTION COLOR OTHER
FUEL TANK
1 FG-S550
60"D x 84" L OUTER
550-GALLON HORIZONTAL FIREGUARD TANK W/ SADDLE SUPPORTS, BELOW.
48" x 72" x 10 GA. INNER TANK (APPROX 4400 LBS.)
6" MONOLITHIC LIGHTWEIGHT CAST CONCRETE INSULATION
60" x 84" x 10 GA. OUTER TANK
W/ 3-2", 1-4", 1-3" EMERG VENT OPENING EA COMPT INNER
2" MONITOR & G EMERG VENT OPENING OUTER TANK
WHITE
2 UL2085 6" HT.
1 FG-COMP48-CYL
281/281 GAL COMPTS
EXTRA COMPARTMENT IN FIREGUARD CYL. TANK
48" INNER TANK DIAMETER - 10 GAUGE
**DOUBLE BULKHEAD**
2 MOR244OM-3-16 AVEVR
244OM 0060 AVEVR
MORRISON 3" #244OM EMERGENCY VENT-16 OZ
16 OZ PRESSURE SETTING-W/ MALE THREADS
1 MOR244OM-6
244OM 0200 AV
MORRISON 6" #2440M EMERGENCY VENT-8 OZ
8 OZ PRESSURE SETTING-W/ MALE THREADS
PRODUCT FILL
2 FILLBOX -2 2" FILLBOX CONTAINER (LESS ANY PARTS)
2 MOR9095A-2 THREAD
2" FMALETHREADX 4" NPT
MORRISON 9095A OVERFILL PREVENTION VALVE
UFC & NFPA 30A OVERFILL 9095AA 3200AVEVR
2 MOR419-2X48 2" DROP TUBE X 4' LONG 419 0600 1T
2 NIP 4X4 4" x 4" PIPE NIPPLE
2 DIX-FBV-200 2" BRASS FULL PORT BALL VALVE
2 MOR73590CA-2 MORRION 2" 90 DEG CHECK VALVE ADAPTOR
73590CA 0200 AV
2 QC2V-AL 2" ALUMINUM DUST CAP
2 MISC-FIT MISC PIPE FITTING & PARTS TO PLUMB
PRODUCT FILL LINES FROM FILL BOX TO TOP OF TANK
NORMAL VENTING
2 MOR749-2 MORRISON 2" PRESSURE VACUUM VENT - 8 0Z
PRESSURE - 0.5 OZ. VACUUM 749 0110 AV
2 NIP2X80 2" x 80" PIPE TBE FOR NORMAL VENT
LEVEL GAUGE W/ OVERFILL ALARM
2 KRU-GLANCE-47-60 KRUEGER "AT-A-GLANCE" DIRECT READING
GAUGE-48" DEEP TANK W/6" INTERSTITIAL
2 KRU-ALARM/DIRECT KRUEDER DIRECT MOUNT OVERFILL ALARM DALARM
INTERSTITIAL MONITORING
1 KRU-LEAK-43-76 KRUEGER "AT-A-GLANCE" DIRECT READING
GAUGE-59" DEPTH - 2" OPENING
1 COUP2 2" PIPE COUPLING
PUMP ASSEMBLY
2 FIL-FR701VA
1/3 HP 18 GPM
FILLRITE FR701V PUMP W/ METER, AUTOMATIC NOZZLE &
4" x 12' HOSE
2 PIPE - BLACK - 1.25 1.25" x 59" NIPPLE TOE FOR SUCTION LEG
FILTER ASSEMBLY
2 CIM2004-3/4 FILTER HEAD - 34 x 34 x 34 50003
2 CIM200E
4" FUEL GUARD FILTER ELEMENT 70002
10 MICRON
2 STREETEL 34 3
4" 90 DEGREE STREET EL
2 NIP.75X8 3
4" x 8" PIPE NIPPLE
HOSE SAFETY BREAK
2 HUS-2274 HUSKY 34" BREAKAWAY HOSE 9" LONG 2274
NEW PART #CP12HW.75l
2 EMCO-A2219-3/4
RECONNECTABLE
4" x 8" PIPE NIPPLE
2 HUS-SWIVEL-3/4 HUSKY 34" M x 34 F HOSE SWIVEL 0350
DECALS
1 PD-NFPA-DIESEL NFPA LABEL - DIESEL (0/2/0)
APPLIED BY MFR.
1 PD-COMBUSTIBLE COMBUSTIBLE DECAL 5.5" x 27" RED ON WHITE
1 PD-NFPA-GASOLINE NFPA LABEL - GASOLINE (1/3/0)
1 PD-FLAMMABLE-LG FLAMMABLE DECAL 5.5" x 27" RED ON WHITE 3 PD-DIESEL "DIESEL" DECAL 4" x 12" 3 PD-UNLEADED "UNLEADED" DECAL 4" x 12" 4 PD-NO SMOKING "NO SMOKING" DECAL 4" x 12"
NOTES
1. BASIS OF DESIGN MANUFACTURER; REFER TO PRODUCT SCHEDULE, LS-111.
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2020, Walker Federal Services, LLCF
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
803IC3005
BJ; IL BJ; TJ
May 22, 2020
FINAL CONSTRUCTION DOCUMENTS
SITE DEVELOPMENT DETAILS
SCHEDULES
LS-211
G .0 .1
W o o d la w n
F a c
R e n
IC
C a d d o c s
L S S it e d e v p la n d e ta il s .d w g
P M T D
S td D W G
T o
P D F .p c
A
PANEL
REPAIR/REPLACE RE-WELD
OTHER
BOLT
(QUAN.)
PICKETS
(QUAN.)
POST
(QUAN.) TOP RAIL BOTTOM RAIL
DEER GUARD
(WHERE
OCCURS)
DEER GUARD
(WHERE
OCCURS)
1 1 4 1
20 7 X X 21 1 1 23 1 25 1 X X 27 1
29 WELD BOTTOM RAIL TO MIDDLE SUPPORT
B1/B2 1 X 3 X 8 X 9 1
11 X 12 X X 13 2 X 17 X 18 X 19 X 20 X
22 4 REFINISH BLISTERED PAINT
24 X REFINISH BLISTERED PAINT
29 1 30 2 33 X 34 1 41 1 46 X 48 1 49 1 50 X 51 1
GATE A
(DOUBLE) 1 REFURBISH GATE HARDWARE TO FULL
WORKING CONDITION
57 1 X 58 1 X 63 1 66 3
C 1 X 3 X 8 1 X
12 2 15 1 17 X 18 X 19 1 X 20 X 23 1 29 X 31 X 32 X 34 X 35 1 X
40 1
REPLACE FOOTING; CUT BOTTOM OF POST 3-4"
ABOVE FG; WELD MIN. 18" MATCHING
EXTENSION & GRIND SMOOTH
47 X 48 1 53 2 55 X 56 X 58 X
GATE B
(DOUBLE)
REPAIR CANE BOLTS; REFURBISH GATE
HARDWARE TO FULL WORKING CONDITION
62 2 X 64 2
D
3 ADD BASE BRACKET; REPLACE FOOTING;
MATCH ADJACENT
10 REPLACE BASE BRACKET; REPLACE FOOTING;
MATCH EXISTING
11 REPLACE BASE BRACKET; REPLACE FOOTING;
MATCH EXISTING
32 ADD BASE BRACKET; REPLACE FOOTING;
MATCH ADJACENT
37 2
E1/E2
GATE C
REFURBISH GATE HARDWARE TO FULL
WORKING CONDITION; PROVIDE LATCH
HARDWARE; MATCH GATE 3 COMPONENTS
GATE D
(double) REFURBISH GATE HARDWARE
GATE E
REFURBISH GATE HARDWARE TO FULL
WORKING CONDITION; PROVIDE RETAINER &
PRECAST CONCRETE BASE TO MATCH GATE C
4 REPLACE CONCRETE FOOTING
8 1
14 1
15 REPAIR/REPLACE BASE OF POST
F N/A
GENERAL:
1. PANEL COUNT BEGINS AT CORNER POST AND CONTINUES IN DIRECTION INDICATED ON LS-101/102.
2. SEAL ALL CONNECTIONS/PENETRATIONS TO MASONRY.
3. REPAIR DAMAGED COMPONENTS TO ORIGINAL NEW CONDITION OR REPLACE WITH COMPONENTS OF EQUAL MATERIAL, GRADE, SIZE, AND SHAPE OF ORIGINAL, AS
APPROVED BY COR. PROVIDE SAMPLES OF NEW COMPONENTS FOR COR'S REVIEW.
4. PROVIDE 15% ALLOWANCE FOR ADDITIONAL REPAIRS TO ITEMS OR CONDITIONS THAT MAY HAVE CHANGED SINCE FIELD SURVEY AND AS DIRECTED BY COR.
REFINISHING - FENCE/GATE PANELS A, B, C:
1. REFINISH PER SPECIFICATIONS ALL SURFACES DAMAGED BY REPAIRS AND OTHER FAILURES AND AS DIRECTED BY COR.
REFINISHING - FENCE/GATE PANELS D, E1, E1, F:
1. STRIP AND REFINISH IN PLACE ALL METAL COMPONENTS PER SPECIFICATIONS.
2. ERECT TENTING OVER/AROUND WORK AREA AS NECESSARY TO CONTROL DUST & FUMES. COMPLETE ALL WORK WITHIN EACH TENTED SECTION BEFORE DISMANTLING TENTING AND ERECTING AT NEXT AREA. ERECT NO MORE THAN ONE 100-FOOT LONG TENT AT EACH OF FENCE D, E, AND F SIMULTANEOUSLY, OR AS AUTHORIZED BY COR.
INCLUDE NO MORE THAN ONE VEHICULAR GATE IN ANY TENT AT ANY GIVEN TIME. COORDINATE TRAFFIC CLOSURES AND TIME REQUIREMENTS FOR ALL WORK WITH COR AND
CEMETERY DIRECTOR.
3. MAINTAIN TENTING MATERIALS IN SECURE CONATION AND GOOD REPAIR AT ALL TIMES.
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2020, Walker Federal Services, LLCF
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
803IC3005
BJ; IL BJ; TJ
May 22, 2020
FINAL CONSTRUCTION DOCUMENTS
SITE DEVELOPMENT DETAILS
FENCE REPAIR TABLE
LS-212
G .0 .1
W o o d la w n
F a c
R e n
IC
C a d d o c s
L S S it e d e v p la n d e ta il s .d w g
P M T D
S td D W G
T o
P D F .p
1. INSTALL TURF PER SPECIFICATION IN ALL DISTURBED
AREAS NOT OTHERWISE PLANTED OR PAVED.
TURF SOD
WWWWWWW
WWWWW
WW
WW
WW
WWWW
WWWW
874874774874874744444
737387877787777
STST
STSTSSSSSSSSSSSSSS
STSTSTSTSTSTSTSTSTSTTTSTSTSTSTSTST
STSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STSTSTSTSTSTSTST
STSTSTSTSTST
STSTTTTT
STST
STSTSSSSSSSSSSSSSS
STST
STST
STST STST STST STST STST STST STST STST STSTSTST
STST
TTTTTTTT
STSTSSSSSTSSTSSSSSST
WW WWWW WW WW WW WW WW WWWWWWWW WW WWWWWW WW WW WWWW WW WWWWWWWWWWWWWWWW
WWWWWWWW
WWWWWWWW
WWWWWWW
WWWW
WW
WW
WW
WWWW
WWWWWWWWW
WWWWWWWWWWW
WW
LP-111LP-111
PLANTING ENLARGEMENT 2
LIMITS OF WORK, UNFENCED
REFER TO 010002 & COR'S DIRECTION
EXISTING TREE; PROTECT PER 015639
TREE AND PLANT PROTECTION
LIMITS OF WORK W/ CONSTRUCTION FENCE
REFER TO 010002 & COR'S DIRECTION
0 10 20 40 60
MATCHLINE SHEET LP-102
PLANTING PLAN
LP-101
MATCHLINE SHEET LP-102
LEGEND
NOTES
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2020, Walker Federal Services, LLCF
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
803IC3005
BJ; IL BJ; TJ
May 22, 2020
FINAL CONSTRUCTION DOCUMENTS
G .0 .1
W o o d la w n
F a c
R e n
IC
C a d d o c s
L P P la n ti n g p la n .d w g
P M T D
S td D W G
T o
P D F .p
LIMITS OF WORK, UNFENCED
REFER TO 010002 & COR'S DIRECTION
EXISTING TREE; PROTECT PER 015639
TREE AND PLANT PROTECTION
LIMITS OF WORK W/ CONSTRUCTION FENCE
REFER TO 010002 & COR'S DIRECTION
TURF SOD
T T
E E E
E E E
E
DS DS
DSDS
DSDS
DS
ST
ST
EEE
T T
888888
ST
ST
SANSAN
W W
CC CC
DSSDSS
EE
GGG
A
GG
AS
G
ASSSSS
G A
G A
G A
G
AA
GGGG
G
A G
ASSSSASSSS
GG
GASGAS
GASGASGG
SGASGASSS
G
AS
G
AS
WW
WW
WW
STSTSTSTSTSTTTSTSTTT
STSTTTTT
STSTTTT
STSTT
STST
STSTTTTT
STST
STSTSSSTSSSSS
STST
STST
STST STST STST STSTSTSTSTST STST STST STSTTT STST STST STST STST STST STST STST STST TTTTTTSTSSTT STST STST STST STST STST STST STST STST STST STST STST STST STST STST STST STST
STST
STST
STST
STST
STST
STST
STST
STST
STST
STST
STST
STST
STST
STST
STST
STST
STST
STST
STST
STST
STST
STSTTTTTTT
STSTSSSTSTSTSTSTSTSSTSTSTSTSTT
STSTSTSTSTSTSTSTSTSTSTSTSTST
STSTSTSTSTSTSTSTSTSTSTSTSTTSTST
STSTSSSSSSSSSSSSSSSSSS
WW
WW
WW
WWWW
TT
TT
WW
S
WW
WWWW
GASGASSS
SAN
SANNNNN
SS
SAN
SAN
SASA
SAN
SAN
SANSANGAGAGAGAGAGAGASS SANSANSANSAN SANSAN NNNNSASAANN SANSAN SANSAN SANSANSSSAS SANSAN SANSAN SANSAN SANSAN SANSAN
SANSAN SANSAN SANSAN
SAN
SAN
SAN
SANNN
SAN
SAN
SASA
SAN
SAN
SAN
SAN
SAN
SANANANNNNNNNNN
SAN
SAN
SAN
SAN
SSASAA
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
AA
| GASGAS GASGAS GASGAS GASGASGAGA GASGAS GASGASSSASAASASSSASASSSSSSGG
WWWWWW WWWWWWWW WW WW
STST STST STST
LP-111LP-111
PLANTING ENLARGEMENT 2
LP-111LP-111
PLANTING ENLARGEMENT 1
1. INSTALL TURF PER SPECIFICATION IN ALL DISTURBED
AREAS NOT OTHERWISE PLANTED OR PAVED.
0 10 20 40 60
MATCHLINE SHEET LP-101
PLANTING PLAN
LP-102
MATCHLINE SHEET LP-101
LEGEND
NOTES
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2020, Walker Federal Services, LLCF
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
803IC3005
BJ; IL BJ; TJ
May 22, 2020
FINAL CONSTRUCTION DOCUMENTS
G .0 .1
W o o d la w n
F a c
R e n
IC
C a d d o c s
L P P la n ti n g p la n .d w g
P M T D
S td D W G
T o
P D F .p
TURF SOD
LIMITS OF WORK, UNFENCED
REFER TO 010002 & COR'S DIRECTION
EXISTING TREE; PROTECT PER 015639
TREE AND PLANT PROTECTION
LIMITS OF WORK W/ CONSTRUCTION FENCE
REFER TO 010002 & COR'S DIRECTION
1. INSTALL TURF PER SPECIFICATION IN ALL DISTURBED
AREAS NOT OTHERWISE PLANTED OR PAVED.
T T
E E E
E E E
AU
RR
BX
RR
DS DS
DS
DS
DS
ST
ST
EE
T T
ST
ST
SANSAN
W W
CC C
DSS
BX
EE
G
AS
G
ASSS
G A
G A
G A
G
AAA
GG
G
AS
G
ASSSSS
GG
GASGAS
GASGASGG
GASGASS
G
AS
G
AS
STST
STSTTT
STST
STSTSTSSTSSSSS
STST
STST
WW
WWWW
TT
TT
WW
S
WW
WWWW
GASGASSS
SAN
SANNNNN
SS
SAN
SAN
SASA
SAN
SAN
SANSANGAGAGAGAGAGAGASS SANSANSASASASA SANSAN ANNNNSASAANN SANSAN SANSAN SANSANSSSAS SANSAN SANSAN SANSAN
SANSAN SANSAN SANSAN
SAN
SAN
SAN
SANNN
SAN
SAN
SS
SAN
SAN
SAN
SAN
SAN
SANANNNNNNNNNN
SAN
SAN
SAN
SAN
SASA
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
AA
| GASGAS GASGAS GASGAS GASASGAGAGAGA
WWWWWW WWWWWWWWWW WW
STST STST STST
TX
VP
TX
AU
AU
888888
T
0 5 10 20 30
LEGEND
NOTES
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2020, Walker Federal Services, LLCF
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
803IC3005
BJ; IL BJ; TJ
May 22, 2020
FINAL CONSTRUCTION DOCUMENTS
PLANTING PLAN
ENLARGEMENTS
LP-111
2 PLANTING ENLARGEMENT 2
1"=10' 1 PLANTING ENLARGEMENT 1
1"=10'
G .0 .1
W o o d la w n
F a c
R e n
IC
C a d d o c s
L P P la n ti n g p la n e n la r.
d w g
P M T D
S td D W G
T o
P D F .p
NOTES:
1. REFER TO SPECIFICATIONS FOR SUBMITTAL REQUIREMENTS INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING: SOIL ANALYSES AND AMENDMENT
RECOMMENDATIONS, SOURCE LIST.
2. COMPLY W/ TAGGING AND/OR PHOTOGRAPHS OF REPRESENTATIVE MATERIAL, IF REQUESTED BY COR.
3. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
4. MEET REQUIREMENTS OF ANSI Z60.1, LATEST ADDITION, FOR ALL PLANT MATERIAL.
5. QUANTITIES GIVEN ARE FOR INFORMATION ONLY. CONTRACTOR IS RESPONSIBLE FOR MEETING THE DESIGN INTENT, AS INDICATED ON PLANTING PLANS.
6. ALL PLANTS SHALL BE HEALTHY, FULL, BALANCED, AND EXCEPTIONALLY HEAVY.
7. PROVIDE TURF PER SPECIFICATIONS IN ALL DISTURBED AREAS NOT OTHERWISE PLANTED OR PAVED.
1 PLANTING NOTES
KEY QTY BOTANICAL NAME COMMON NAME SIZE TYPE SPACING REMARKS
SHRUBS
BX 8 Buxus x 'GREEN MOUNTAIN' GREEN MOUNTAIN BOXWOOD 24" HT. CONT. 30" O.C.
RR 23 Rosa 'RADWHITE' PP20,273 ROSE WHITE KNOCK OUT 24" HT. CONT. 30" O.C.
TX 6 Taxus x media 'DENSIFORMIS' DENSIFORMIS YEW 30" SPR. CONT. 36" O.C.
VP 3 Viburnum prunifolium 'OVAZUM' OVATION BLACKHAW 5' HT. CONT. 48" O.C.
GROUNDCOVERS/PERENNIALS/ORNAMENTAL GRASSES
AU 65 Arctostaphylos uva-ursi 'MASSACHUSETTS' BEARBERRY 12" SPR. CONT. 18" O.C.
TURF
MIX
50% KENTUCKY BLUEGRASS
SOD25% TURF-TYPE TALL FESCUE
25% PERENNIAL RYEGRASS
LATEST RECOMMENDATIONS BY NATIONAL TURFGRASS EVALUATION FOR THE NORTHEAST REGION, MEAN
RATING >6.7
SET TOP OF ROOT BALL FLUSH
W/ ADJACENT FG
3" DEPTH MULCH
CUT & REMOVE ROPES, BURLAP, BASKET
& ALL NON-BIODEGRADABLE MATERIAL
PLANTING SOIL MIX; REFER
TO SPECIFICATIONS
2"
NOTES:
1. FOR CONTAINER-GROWN MATERIAL, REMOVE CONTAINER WITHOUT CRACKING ROOT BALL
AND MAKE (3) 1" DEEP VERTICAL CUTS, EQUALLY SPACED ABOUT ROOT BALL, FULL HEIGHT.
FULL WIDTH OF BED FRACTURED SUBGRADE
1' -6
8"
SCARIFY SIDES & BOTTOM
OF EXCAVATION
±5
UNDISTURBED SOIL
3 SHRUB PLANTING
SET TOP OF ROOT BALL FLUSH
W/ ADJACENT FG
3" DEPTH MULCH
PLANTING SOIL MIX; REFER
TO SPECIFICATIONS
FULL WIDTH OF BED FRACTURED SUBGRADE
1' -6
8"
SCARIFY SIDES & BOTTOM OF
EXCAVATION
±5
UNDISTURBED SOIL
3 GROUNDCOVER/PERENNIAL PLANTING
PLANTING DETAILS &
PLANT SCHEDULE
LP-201
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2020, Walker Federal Services, LLCF
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
803IC3005
BJ; IL BJ; TJ
May 22, 2020
FINAL CONSTRUCTION DOCUMENTS
G .0 .1
W o o d la w n
F a c
R e n
IC
C a d d o c s
L P P la n ti n g d e ta il s s c h e d u le .d w g
P M T D
S td D W G
T o
P D F .p
DEMOLISH ELEMENT
DEMOLISH EXISTING
DOOR
DS
EXISTING WALL TO
REMAIN
EXISTING DOOR
EXISTING DOOR /
STORM DOOR
COMBINATION
NEW DOOR
NEW WALL
DOWNSPOUT
SOFFIT VENT
OVERHEAD ELEMENT
FIRE RATED PARTITION
SURFACE MOUNTED
LINEAR LED FIXTURE
SURFACE MTD OR
RECESSED LIGHT FIXTURE
RECCESSED LED
DOWNLIGHT OR WALL
WASHER
LED WALL SCONCE
EXTERIOR SURFACE
MOUNTED
LED WALL PACK
SURFACE MTD LIGHT
FIXTURE
EXIT LIGHT
SURFACE MTD LIGHT
FIXTURE
SUPPLY AIR DIFFUSER
RETURN AIR DIFFUSER
EXHAUST FAN
X
X
X
X
X
X
EX
EM
DOOR NUMBER
FINISH TYPE
EQUIPMENT / FURNITURE
PLUMBING FIXTURE
NUMBER
ACCESSORIES NUMBER
WALL TYPE
P-1
FE FIRE EXTINGUISHER
ARCHITECTURAL
ABBREVIATIONS, SYMBOLS
AND NOTES
A-001
ABBREVIATIONS
³
SYMBOLS
BREAK, ROUND
BREAK, STRAIGHT
DETAIL INDICATOR
DIMENSION LINE
DRAWING BLOCK TITLE
ELEVATION INDICATOR
ELEVATION INDICATOR
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2020, Walker Federal Services, LLC
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
803IC3005
IK; FW FW; CL
May 22, 2020
FINAL CONSTRUCTION DOCUMENTS
-- SECTION INDICATOR
- DETAIL
SCALE
DIM
0 X X X X
NORTH ARROW
SCALE INDICATOR
RAMPDN
DN
RE
F
DNDN
EGRESS PATH 29'
16'-0"
'-0
'-4
'-6
ASD
EGRESS PATH 60'
RE
F
CL
OS
ET
4A
KIT
CH
EN
UT
ILI
TY
RM
RE
ST
RO
OM
LO
BB
Y
OF
FIC
E
RE
ST
RO
OM
OF
FIC
E
OF
FIC
E
HA
LL
CL
OS
ET
8A
CL
OS
ET
9A
CL
OS
ET
0A
IT
CL
OS
ET
5A
CL
OS
ET
2A
EN
T.
PO
RC
H
4B
PO
RC
H
9B
CL
OS
ET
7A
LO
UN
GE
'-0
1 HOUR
RATED
PARTITION
41'-4"
15'-0"
RAMP DN
EG
RE
SS
PA
TH
CLOSET
102A
RESTROOM
GARAGE
HAZM
AT STOR
RESTROOM
CLOSET
101A
26'-0"
'-0
- 5
'-7
12'-10 1/2"
'-0
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2020, Walker Federal Services, LLC
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
803IC3005
IK; FW FW; CL
May 22, 2020
FINAL CONSTRUCTION DOCUMENTS
1 EXISTING ADMINISTRATION BUILDING
3/16" = 1'-0"
CODE ANALYSIS
A-002
BUILDING CODE ANALYSIS
1. SCOPE OF WORK
RENOVATION/IMPROVEMENT OF EXISTING CEMETERY FACILITIES INCLUDING A NEW GRAVESITE
LOCATOR KIOSK, NEW STORAGE BUILDING, ADMINISTRATIVE AND MAINTENANCE BUILDING
RENOVATIONS, MAINTENANCE YARD IMPROVEMENTS, SITE FENCE REPAIR.
3 SITE PLAN
1/16" = 1'-0"
4 STORAGE BUILDING
3/16" = 1'-0"
2 EXISTING MAINTENANCE BUILDING
3/16" = 1'-0"
A-002
A-002
A-002
2. APPLICABLE CODES
2015 BUILDING CODE OF NEW YORK STATE
2015 EXISTING BUILDING CODE OF NEW YORK STATE
2015 FIRE CODE OF NEW YORK STATE
2015 NEW YORK ENERGY CONSERVATION CODE
2015 PLUMBING CODE OF NEW YORK STATE
2015 MECHANICAL CODE OF NEW YORK STATE
2015 FUEL GAS CODE OF NEW YORK STATE
2015 MAINTENANCE CODE OF NEW YORK STATE
ABA ACCESSIBILITY STANDARDS
3. BUILDING OCCUPANCY USE GROUPS
BUSINESS, GROUP B
STORAGE, GROUP S-1
OPEN PARKING GARAGE, U
4. CODE ANALYSIS
EXISTING ADMINISTRATION BUILDING EXISTING PROPOSED
CONSTRUCTION TYPE VB NO CHANGE
FIRE SUPPRESSION SYSTEM NONE NO CHANGE
BUILDING HEIGHT 16'-0" (1 STORY) NO CHANGE
BUILDING AREA 1,578 SF NO CHANGE
BUILDING USE GROUP B (BUSINESS) NO CHANGE
OCCUPANT LOAD BY USE GROUP 16 (100 GSF) NO CHANGE
NO. OF EXITS REQUIRED 2 NO CHANGE
EXITS PROVIDED 4 NO CHANGE
MAXIMUM TRAVEL DISTANCE 200' NO CHANGE
PRIMARY STRUCTURAL FRAME 0 HOURS
BEARING WALLS EXTERIOR 0 HOURS
INTERIOR NON BEARING WALLS
AND PARTITIONS 0 HOURS
FLOOR CONSTRUCTION AND
ASSOCIATED SECONDARY MEMBERS 0 HOURS
EXISTING MAINTENANCE BUILDING EXISTING PROPOSED
CONSTRUCTION TYPE III B NO CHANGE
FIRE SUPPRESSION SYSTEM NONE NO CHANGE
BUILDING HEIGHT 16'-0" (1 STORY) NO CHANGE
BUILDING AREA 1,456 SF NO CHANGE
BUILDING USE GROUP S-1 (STORAGE) NO CHANGE
OCCUPANT LOAD BY USE GROUP 5 (300 GSF) NO CHANGE
NO. OF EXITS REQUIRED 1 NO CHANGE
EXITS PROVIDED 1 NO CHANGE
MAXIMUM TRAVEL DISTANCE 75'
PRIMARY STRUCTURAL FRAME 0 HOURS
BEARING WALLS EXTERIOR 2 HOURS
INTERIOR NON BEARING WALLS
AND PARTITIONS 0 HOURS
FLOOR CONSTRUCTION AND
ASSOCIATED SECONDARY MEMBERS 0 HOURS
STORAGE BUILDING PROPOSED
CONSTRUCTION TYPE II B
FIRE SUPPRESSION SYSTEM NONE
BUILDING HEIGHT 14'-0" (1 STORY)
BUILDING AREA 310 SF
BUILDING USE GROUP S-1 (STORAGE)
OCCUPANT LOAD BY USE GROUP 2 (300 GSF)
NO. OF EXITS REQUIRED 1
EXITS PROVIDED 1
MAXIMUM TRAVEL DISTANCE 75'
PRIMARY STRUCTURAL FRAME 0 HOURS
BEARING WALLS EXTERIOR 0 HOURS
INTERIOR NON BEARING WALLS
AND PARTITIONS 0 HOURS
FLOOR CONSTRUCTION AND
ASSOCIATED SECONDARY MEMBERS 0 HOURS
5. INTERIOR FINISHES
FLAME SPREAD INDEX REQUIREMENTS FOR WALLS AND CEILING FINISHES: B S-1
INTERIOR EXIT STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS A B
CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS B B
ROOMS AND ENCLOSED SPACES C C
6. FIRE SUPPRESSION SYSTEMS
BUILDINGS ARE UNSPRINKLERED. PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN
ACCORDANCE WITH NFPA 10.
EXISTING
ADMINISTRATIVE
BUILDING
B (BUSINESS)
EXISTING
MAINTENANCE
BUILDING
S-1 (STORAGE)
STORAGE BUILDING
S-1 (STORAGE)
A-002
5 OPEN PARKING GARAGE
3/16" = 1'-0"
OPEN PARKING GARAGE PROPOSED
CONSTRUCTION TYPE IIIB
FIRE SUPPRESSION SYSTEM NONE
BUILDING HEIGHT 11'-0" (1 STORY)
BUILDING AREA 240 SF
BUILDING USE GROUP U (GARAGE)
OCCUPANT LOAD BY USE GROUP 2 (200 GSF)
NO. OF EXITS REQUIRED 1
EXITS PROVIDED 1
MAXIMUM TRAVEL DISTANCE 75'
OPEN PARKING
GARAGE
U (UTILITY)
OCCUPANCY
SF1,578
B
OCCUPANCY
SF1,456
S-1
OCCUPANCY
SF310
S-1
OCCUPANCY
SF240
U
RAMPDN
DN
RE
F
DNDN
30'-01 2"
5'- 61 4"
LEGEND
NOTES
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2020, Walker Federal Services, LLC
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
803IC3005
IK; FW FW; CL
May 22, 2020
FINAL CONSTRUCTION DOCUMENTS
BUILDING LOCATION PLAN
A-003
AE-101
AE-104
AE-105
AE-103
ADMINISTRATION BUILDING
OPEN PARKING GARAGE
MAINTENANCE BUILDING
STORAGE BUILDING
GRAVESITE LOCATOR
TEMPORARY OFFICE TRAILER, REFER TO LS-206
0 4' 8' 16' 24'
LEGEND
DS
DS
DS
DS
DS
RA
M
P
DN
DN
DN
DN
EXISTING
FIREPLACE
EXISTING WALL TO REMAIN
EXISTING 2X WOOD
STUDS TO REMAIN, TYP.
EXISTING 2X
WOOD STUDS
TO REMAIN
REMOVE EXISTING
GYP BD.
REMOVE
EXISTING WALL
REMOVE
EXISTING WALL
REMOVE EXISTING
GYP BD.
REMOVE EXISTING
GYP BD. CEILING
EXISTING CEILING JOISTS
EXISTING INSULATION
EXISTING 2X
WOOD STUDS TO
REMAIN
LEGEND
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2020, Walker Federal Services, LLC
Walker Federal Services, LLC
FACILITY RENOVATION,
IMPROVEMENTS, AND
REPAIRS
WOODLAWN NATIONAL CEMETERY
803IC3005
IK; FW FW; CL
May 22, 2020
FINAL CONSTRUCTION DOCUMENTS
1 FLOOR DEMOLITION PLAN
1/4" = 1'-0"
ADMINISTRATION BUILDING
DEMOLITION PLANS
AD-101
1. VERIFY ALL DIMENSIONS IN FIELD PRIOR TO CONSTRUCTION.
NOTIFY COR OF ANY DISCREPANCIES PRIOR TO PROCEEDING
WITH THE WORK.
2. DO NOT SCALE DRAWINGS.
3. ALL DIMENSIONS ARE GIVEN TO FINISHED WALL SURFACES
AND SHALL BE CONSIDERED AS CLEAR OPENINGS UNLESS
NOTED OTHERWISE.
4. REFER TO MEP DRAWINGS FOR MEP DEMOLITION
REQUIREMENTS.
REMOVE CARPET IN LOBBY.
EXISTING CEILING HATCH DOOR TO ATTIC TO REMAIN.
EXISTING FLOOR HATCH DOOR TO CRAWL SPACE TO REMAIN.
REMOVE ALL EXISTING PLUMBING FIXTURES IN STAFF
RESTROOM.
REMOVE EXISTING WALL, DOOR AND FRAME.
REMOVE ALL EXISTING RADIATORS AND WINDOW A/C UNITS
THROUGHOUT BUILDING, TYP.
REMOVE EXISTING WALL CABINET.
REMOVE ALL EXISTING FIXTURES, CABINETS, SINK AND
REFRIGERATOR IN KITCHEN.
REMOVE EXISTING MECHANICAL EQUIPMENT. SEE MEP
DRAWINGS FOR DETAILS.
REMOVE FLOOR AND WALL TILES IN STAFF RESTROOM.
REMOVE VINYL FLOORING AND BASE IN KITCHEN AND UTILITY
ROOM.
REMOVE EXISTING DOWNSPOUTS AND GUTTERS.
REMOVE ALL EXISTING INTERIOR AND EXTERIOR LIGHT
FIXTURES, TYP.
REMOVE ALL EXISTING ROOFING MATERIAL. INSPECT
SUBSTRATE AND REPAIR OR REPLACE UP TO 10% OF ROOF
SUBSTRATE .
REMOVE EXISTING CAST IRON STOVE. SEE AE-101 AND
PLUMBING DRAWINGS FOR FIREPLACE RESTORATION WORK.
REMOVE EXISTING GRAVESITE LOCATOR CABINET.
REMOVE EXISTING GYP. BOARD INSIDE EXISTING CLOSETS TO
EXPOSE EXISTING WOOD STUDS TO REMAIN. SEE DETAIL
5/AD-101.
AT NEW IT CLOSET, REMOVE EXISTING GYP. BOARD CEILING
TO EXPOSE CEILING JOISTS TO REMAIN. SEE DETAIL 4/AD-101.
REMOVE EXISTING TOILET, SINK, PAPER TOWEL AND SOAP
DISPENSERS IN PUBLIC RESTROOM. EXISTING FLOOR AND
WALL TILES, GRAB BARS AND OTHER ACCESSORIES TO
REMAIN.
DELETE CONCRETE STOOP
2 CEILING DEMOLITION PLAN
1/4" = 1'-0"
3 ROOF DEMOLITION PLAN
1/4" = 1'-0"
EXISTING BRICK
CHIMNEY AND VENTS
EXISTING GABLE
VENT
EXISTING GABLE
VENT
EDGE OF ROOF
OVERHANG ABOVE
NOTES
AD-101
5 CLOSET WALL DEMOLITION DETAIL
1" = 1'-0"
4 CLOSET CEILING DEMOLITION DETAIL
1" = 1'-0"
AD-101
File details come from the government source that posted it. Updated .