S02 - 803IC3015 Bid Dwgs Bath Bk06.pdf

PDF 19 MB Posted

Attached to
Z1QA--Facility Renovations at the Woodlawn and Bath National Cemeteries.
Solicitation number
36c78620b0009
Issued by

About this file

This file contains details of a federal contract opportunity for facility renovations and improvements. The solicitation number is 36c78620b0009 and seeks bids for renovations at the Woodlawn and Bath National Cemeteries. The work includes facility renovations, improvements and repairs. The contracting agency is the Department of Veterans Affairs National Cemetery Administration. The description indicates the opportunity is for renovating and updating facilities at the two national cemeteries to improve conditions. The attached file appears to contain bid drawings to assist contractors in preparing responses for the work outlined.

View the file

Other files

File Type Posted
S06 - A0003 - Amendment.docx DOCX document
S06 - HazMat Information - WB.pdf PDF
S06 - Amendment 0002.docx DOCX document
A2 - Pre-Bid Walk-Thru Sign In Sheet.PDF PDF
A1 - 803IC3015 Bid Dwgs Bath Bk02A.pdf PDF
S05 - Amendment 0001.docx DOCX document
S02 - 824IC3005 Bid Dwgs Woodlawn Bk09.pdf PDF
S02 - 803IC3015 Bid Dwgs Bath Bk05.pdf PDF
S02 - 824IC3005 - Geotechnical Report - Woodlawn.pdf PDF
S02 - 803IC3015 Bid Dwgs Bath Bk02.pdf PDF
S02 - 824IC3005 Bid Dwgs Woodlawn Bk12.pdf PDF
S02 - Scope of Work Final - Woodlawn-Bath.pdf PDF
S02 - 803IC3015 Bid Specs Bath Bk.pdf PDF
S02 - 803IC3015 Bid Dwgs Bath Bk03.pdf PDF
S02 - 803IC3015 Bid Dwgs Bath Bk01.pdf PDF
S02 - 824IC3005 Bid Dwgs Woodlawn Bk13.pdf PDF
ATTACHMENT 05 - Cost Estimate Worksheet - WB.pdf PDF
S02 - 824IC3005 Bid Dwgs Woodlawn Bk03.pdf PDF
S02 - 824IC3005 Bid Dwgs Woodlawn Bk06.pdf PDF
S02 - 803IC3015 Bid Dwgs Bath Bk07.pdf PDF
P07 - WD - NY20200005 - Woodlawn NC.pdf PDF
S02 - 824IC3005 Bid Dwgs Woodlawn Bk10.pdf PDF
S02 - 824IC3005 Bid Dwgs Woodlawn Bk05.pdf PDF
S02 - 36C786-20-B-0009 - Solicitation.pdf PDF
P07 - WD - NY20200048 - Bath NC.pdf PDF
S02 - 803IC3015 - Geotechnical Report - Bath.pdf PDF
S02 - 824IC3005 Bid Dwgs Woodlawn Bk01.pdf PDF
S02 - 824IC3005 Bid Specs Woodlawn Bk.pdf PDF
S02 - 803IC3015 Bid Dwgs Bath Bk04.pdf PDF
S02 - 824IC3005 Bid Dwgs Woodlawn Bk02.pdf PDF
S02 - 824IC3005 Bid Dwgs Woodlawn Bk07.pdf PDF
S02 - 824IC3005 Bid Dwgs Woodlawn Bk08.pdf PDF
S02 - 824IC3005 Bid Dwgs Woodlawn Bk11.pdf PDF
S02 - 824IC3005 Bid Dwgs Woodlawn Bk04.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2018, TIER4 DESIGN, LLC.

Walker Federal Services, LLC

FACILITY RENOVATION,

IMPROVEMENTS, AND

REPAIRS

BATH NATIONAL CEMETERY

803IC3015

TDF MLP

JUNE 5, 2020

FINAL CONSTRUCTION DOCUMENTS

MH-201

MECHANICAL SCHEDULES

A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2018, TIER4 DESIGN, LLC.

Walker Federal Services, LLC

FACILITY RENOVATION,

IMPROVEMENTS, AND

REPAIRS

BATH NATIONAL CEMETERY

803IC3015

TDF MLP

JUNE 5, 2020

FINAL CONSTRUCTION DOCUMENTS

MH-202

MECHANICAL SCHEDULES

A

A AMPERE

AC AIR CONDITIONING

ACV AUTOMATIC CONTROL VALVE

ACD AUTOMATIC CONTROL DAMPER

AD ACCESS DOOR

AFF ABOVE FINISHED FLOOR

ALM ALARM

AP ACCESS PANEL

ARCH ARCHITECT

AS AIR SEPARATOR

B

BFP BACK FLOW PREVENT

BHP BREAK HORSE POWER

BOP BOTTOM ELEVATION OF PIPE

BWV BACK WATER VALVE

C

CFM CUBIC FEET PER MINUTE

CLG CEILING

CO CLEAN-OUT

CP CONDENSATE PUMP

D

D DRAIN

DDC DIRECT DIGITAL CONTROL

DIA DIAMETER

DIM DIMENSION

DN DOWN

DX DIRECT EXPANSION

E

(E) EXISTING

EX. EXISTING

EWC ELECTRIC WATER COOLER

EA EACH

EFF EFFICIENCY

ELEC ELECTRICAL

EMT ELECTRICAL METAL TUBE CONDUIT

ES END SWITCH

ET EXPANSION TANK

F

FA FREE AREA

FMT FLOW METER/TRANSMITTER

FPM FEET PER MINUTE

FT FEET

FZ FREEZE STAT

G

G GAS

H

H HEIGHT

HB HOSE BIBB CONNECTION WITH CHAINED CAP

HC HEATING COIL

HOA HAND-OFF-AUTOMATIC SWITCH

HP HORSE POWER

HW HOT WATER

HWR HOT WATER RETURN (DOMESTIC)

HWS HOT WATER SUPPLY (DOMESTIC)

HVAC HEATING VENTILATION AIR CONDITIONING

HX HEAT EXCHANGER

HZ HERTZ

I

IN INCHES

INWC INCHES OF WATER COLUMN

K

KW KILOWATTS

L

LAV LAVATORY

LF LINEAR FEET

LPR LOW PRESSURE CONDENSATE RETURN

LPS LOW PRESSURE STEAM SUPPLY

LSPS LOW STATIC PRESSURE SWITCH

M

MAV MANUAL AIR VENT

MIN MINIMUM

MPR MEDIUM PRESSURE CONDENSATE RETURN

MPS MEDIUM PRESSURE STEAM SUPPLY

N

N/A NOT APPLICABLE

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NUM NUMBER

NTS NOT TO SCALE

O

OCC OCCUPIED

P

P PUMP

PC PUMPED CONDENSATE

PD PRESSURE DROP

PLBG PLUMBING

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

R

RET RETURN

REQ REQUIRED

RI RUN INDICATOR

RPM REVOLUTIONS PER MINUTE

S

SA SOUND ATTENUATOR

SP STATIC PRESSURE SENSOR

SQFT SQUARE FEET

S/S START/STOP

SK SINK

T

TEMP TEMPERATURE

TOP TOP ELEVATION OF PIPE

TYP TYPICAL

U

UNOCC UNOCCUPIED

UNO UNLESS NOTED OTHERWISE

UR URINAL

V

V VENT

VTR VENT THRU ROOF

VIF VERIFY IN FIELD

VS VIBRATION SWITCH

W

W WIDTH

WMS WIRE MESH SCREEN

WC WATER CLOSET

GENERAL ABBREVIATIONS

VALVE

PIPE UNION

PLUMBING SYMBOLS LEGEND

END CAP

PIPE RISE

PIPE DROP

TOP TAKE-OFF

BOTTOM TAKE-OFF

PIPE BREAK

AAV

MANUAL VALVE WITH MEMORY STOP (BALANCING)

CAPPED VALVE WITH HOSE BIBB AND CHAIN

CHECK VALVE

Y-STRAINER

BASKET STRAINER

AUTOMATIC VALVE, 2-POSITION ACTUATOR

AUTOMATIC VALVE, MODULATING ACTUATOR

3-WAY VALVE, 2-POSITION ACTUATOR

3-WAY VALVE, MODULATING ACTUATOR

PRESSURE GAGE WITH GAGE CLOCK

TEMPERATURE SENSOR

PRESSURE / TEMPERATURE WELL

AUTOMATIC AIR VENT WITH ISOLATION VALVE

MANUAL AIR VENTMAV

FLEXIBLE CONNECTION

PIPE GUIDE

ANCHOR

UP

DN

DIRECTION OF FLOW IN PIPE

PITCH PIPE UP IN DIRECTION OF FLOW

PITCH PIPE DOWN IN DIRECTION OF FLOW

1. GENERAL PROVISIONS

A. THE GENERAL AND SPECIAL CONDITIONS GOVERN THIS

WORK TO THE EXTENT THAT THEY APPLY. THE

DRAWINGS AND THE SPECIFICATIONS ARE

COMPLEMENTARY TO EACH OTHER AND WHAT IS

CALLED FOR BY ONE SHALL BE BINDING AS IF CALLED FOR

BY BOTH.

B. THE CONTRACTOR MUST FULLY EXAMINE THE

DRAWINGS, SPECIFICATIONS AND JOB SITE AND FULLY

INFORM HIMSELF OF ALL EXISTING CONDITIONS AND

WORK REQUIRED BY THE DRAWINGS AND

SPECIFICATIONS BEFORE SUBMITTING HIS BID.

C. PROTECT WORK AT ALL TIMES FROM DAMAGE. RESTORE

ALL DAMAGED WORK TO A NEW CONDITION BEFORE

FINAL ACCEPTANCE.

D. ENTIRE INSTALLATION MUST CONFORM TO ALL CITY

CODES THAT GOVERN AND TO ALL APPLICABLE

REQUIREMENTS OF THE NATIONAL FIRE PROTECTION

ASSOCIATION.

E. THIS CONTRACT INCLUDES ALL EXCAVATION, BACKFILL,

LABOR, PIPING, MATERIALS, FIXTURES AND EQUIPMENT

NECESSARY FOR THE WORK.

F. ORDER AND OBTAIN ALL NECESSARY TESTS, PERMITS

AND CERTIFICATES OF APPROVAL, AND PAY ANY

REQUIRED FEES FOR SAME.

G. ALL LOCATIONS AND ELEVATIONS OF SEWER AND WATER

SERVICE NEEDS VERIFY ON THE JOB SITE PRIOR TO

ACTUAL CONSTRUCTION. IF UTILITIES CANNOT BE

CONNECTED AS SHOWN, NOTIFY THE COR IMMEDIATELY.

H. EQUIPMENT CAPACITIES AND MANUFACTURER MODEL

NUMBERS ARE SPECIFIED ON THE DRAWINGS.

I. MATCH ALL EQUIPMENT REQUIRING ELECTRIC POWER

WITH THE POWER TO BE SUPPLIED. SEE ELECTRICAL

DRAWINGS. ELECTRICAL CONNECTIONS BY ELECTRICAL

CONTRACTOR. ALL ELECTRIC REQUIREMENTS MUST BE

COORDINATED WITH THE ELECTRICAL CONTRACTOR.

J. ALL PIPING SHALL BE TESTED IN ACCORDANCE WITH THE

LOCAL CODE REQUIREMENTS AND PROVED TIGHT.

LEAKING JOINTS SHALL BE REMADE, NOT CAULKED, AND

TESTED.

K. INSTRUCT THE GOVERNMENT IN THE OPERATION AND

MAINTENANCE OF ALL COMPONENTS OF THE

INSTALLATION.

L. START-UP AND TEST ALL SYSTEMS.

M. PROVIDE LISTED FIRE CAULKING AND/OR SEALANT

SYSTEMS WHEN PENETRATING FLOORS (2 HR) OR CHASE

(2 HR).

N. PERFORM ALL WORK ABOVE, BELOW, IMMEDIATELY

ADJACENT TO THEN-OCCUPIED SPACES OUTSIDE OF

NORMAL BUSINESS HOURS UNLESS OTHERWISE

AUTHORIZED BY COR.

O. MAINTAIN EXISTING OR PROVIDE NEW UTILITIES,

SYSTEMS, AND SERVICES TO OCCUPIED SPACES AT ALL

TIMES. NO OUTAGES ARE PERMITTED DURING NORMAL

BUSINESS HOURS. COORDINATE ALL OUTAGES DURING

CHANGE-OVERS BETWEEN PHASES WITH CEMETERY

DIRECTOR NOT LESS THAN 7 DAYS IN ADVANCE.

4. BASIC MATERIALS AND METHODS

A. EXCAVATION AND BACKFILL MUST CONFORM TO ALL

MINIMUM REQUIREMENTS ESTABLISHED BY THE

ARCHITECT.

B. MAKE ALL PIPING CONNECTIONS TO EQUIPMENT WITH

GROUND JOINT UNIONS OR EQUIVALENT.

C. PIPE HANGERS AND SUPPORTS: CLEVIS OR SPLIT RING

TYPES; SPACING AND ROD SIZE AS RECOMMENDED IN

ASHRAE HANDBOOK AND IN ACCORDANCE WITH

INDUSTRY PRACTICE. BAND IRON HANGERS SHALL NOT

BE USED. HANGERS AND ACCESSORIES SHALL BE

CARPENTER & PATERSON, OR APPROVED EQUAL.

D. PROVIDE ESCUTCHEON PLATES WHEREVER PIPES PASS

THROUGH WALLS OR FLOORS; CHROME PLATED IN

EXPOSED AREAS.

E. VALVES: ALL 125 LB. STEAM CLASS. ALL BRONZE.

(1) GATE VALVES: SOLID DISC TYPE, UNION BONNET.

STOCKHAM, OR APPROVED EQUAL.

(2) DRAIN VALVE: 3/4" BRONZE GLOBE VALVE WITH

HOSE THREAD ADAPTER.

(3) PROVIDE GATE VALVE OR STOP IN WATER LINES

TO EACH PLUMBING FIXTURE.

(4) APPROVED BALL VALVES MAY BE USED IN LIEU OF

GATE VALVES, 2" MAX SIZE.

F. PIPING SHOULD NOT BE IN DIRECT CONTACT WITH

STRUCTURAL MEMBERS. SLEEVE ALL OPENINGS IN

MASONRY WALLS & SLABS.

3. INSULATION AND SOUNDLINING

A. ALL OWENS - CORNING FIBERGLASS PRODUCTS

INDICATED, OR APPROVED EQUAL. INSTALL MATERIALS

AND ACCESSORIES IN ACCORD WITH MANUFACTURER'S

RECOMMENDATIONS.

B. ALL INSULATION PRODUCTS MUST MEET UL RATINGS OF

FLAME SPREAD 25 AND SMOKE DEVELOPED 50.

C. PIPING - ONE PIECE 25 ASJ/SSL FITTINGS AND VALVES

INSULATED WITH SAME THICKNESS OF MITERED PIPE

INSULATION, GLASS CLOTH REINFORCED, DOUBLE MATIC

COATING.

(1) DOMESTIC HOT WATER: R 3.6.

(2) DOMESTIC COLD WATER IN NON-CONDITIONED

SPACE AND WHERE SUBJECT TO CONDITION.

(3) EXPOSED PIPING AT FIXTURE CONNECTIONS

SHALL NOT BE INSULATED.

D. VAPOR BARRIER ON COLD PIPING SHALL BE

CONTINUOUS.

4. PLUMBING

A. PIPING.

(1) ABOVE GROUND SOIL, WASTE AND VENT PIPING:

CAST IRON PIPE AND FITTINGS.

(2) ABOVE GROUND DOMESTIC WATER PIPING:

COPPER PIPE AND FITTINGS.

B. CLEANOUT: JOSAM NO. 56040 OR APPROVED EQUAL, AS

REQUIRED BY CODE.

PLUMBING NOTES

SANITARY PIPE NEW

SANITARY PIPE EXISTING

VENT PIPE NEW

VENT PIPE EXISTING

PLUMBING EQUIPMENT NEW

PLUMBING EQUIPMENT EXISTING

COLD WATER PIPE NEW

COLD WATER PIPE EXISTING

HOT WATER PIPE NEW

HOT WATER PIPE EXISTING

CONNECT NEW TO EXISTING

LIMIT OF DEMOLITION

KEY NOTE SYMBOL

SANITARY PIPE DEMO

VENT PIPE DEMO

PLUMBING EQUIPMENT DEMO

COLD WATER PIPE DEMO

HOT WATER PIPE DEMO

X X X

X X X

X X X

X X X

X X X

STORM WATER PIPE NEW

STORM WATER PIPE EXISTING

STORM WATER PIPE DEMOX X

ST

ST

ST

(AS APPLICABLE) (AS APPLICABLE)(AS APPLICABLE)

DATA

TAG

DATA

TAG

EQUIPMENT TAGS

EQUIPMENT TAG REQUIRING

AN ELECTRICAL CONNECTION

EQUIPMENT TAG NOT REQUIRING

AN ELECTRICAL CONNECTION,

DATA CAN BE EQUIPMENT NUMBER

AND/OR FLOW SETPOINT

PT

BACK WATER VALVE

BWV

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2018, TIER4 DESIGN, LLC.

Walker Federal Services, LLC

FACILITY RENOVATION,

IMPROVEMENTS, AND

REPAIRS

BATH NATIONAL CEMETERY

803IC3015

TDF MLP

JUNE 5, 2020

FINAL CONSTRUCTION DOCUMENTS

P-001

PLUMBING SYMBOLS,

ABBREVIATIONS AND

GENERAL NOTES

NOTES

1. ALL EXISTING SANITARY PIPING WITH THE EXISTING BUILDING (PHASE III AREA) IS

BURIED BELOW A SLAB ON GRADE.

2. FOR EQUIPMENT SHOWN TO BE REMOVED, PATCH AND SEAL REMAINING WALLS,

FLOORS AND/OR ROOF WORK TO MAINTAIN THAT ELEMENT'S PREVIOUS INTEGRITY.

REFER TO AD-101 BUILDING DEMOLITION PLAN FOR FURTHER REQUIREMENTS.

3. NO SERVICE OUTAGES ARE PERMITTED DURING NORMAL BUSINESS HOURS.

COORDINATE ALL OUTAGES WITH COR NOT LESS THAN 7 DAYS IN ADVANCE.

SIMILARLY, COORDINATE ALL WORK THAT OCCURS WITHIN THE OCCUPIED BUILDING

(EVEN IF IT DOES NOT INVOLVE AN OUTAGE) WITH THE COR NOT LESS THAN 7 DAYS

IN ADVANCE.

LEGEND

EX. FD

GARAGE

WORKSHOP

CLOSET

BREAK RM

BREAK RM

MECH

HALL

WOMEN

MEN

OFFICE

LOBBY

VEST

STORAGE

EX. FD

EX. CO

4"

4"

3"

1.5"

4"

X X

X

X X

X

XX

X

CAPPED FORMER CONNECTION TO SINK.

DN

DN

DN

UP

PHASE IIPHASE III

PHASE IIPHASE III

X

X X

PHASE I

THE EXISTING CLEAN-OUT WILL BE

DEMOLISHED IN PHASE I TO MAKE ROOM

FOR THE INCOMING SIDEWALK. SEE

PP-101 FOR ADDITIONAL PHASE-I WORK.

COORDINATE SERVICE OUTAGE PER

NOTES ON THIS SHEET.

EX. CO

PLUMBING DEMOLITION

SANITARY PLANS

PD-101

0 2 4 8 12

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2018, TIER4 DESIGN, LLC.

Walker Federal Services, LLC

FACILITY RENOVATION,

IMPROVEMENTS, AND

REPAIRS

BATH NATIONAL CEMETERY

803IC3015

TDF MLP

JUNE 5, 2020

FINAL CONSTRUCTION DOCUMENTS

1. FOR EQUIPMENT SHOWN TO BE REMOVED, PATCH AND SEAL REMAINING WALLS,

FLOORS AND/OR ROOF WORK TO MAINTAIN THAT ELEMENT'S PREVIOUS INTEGRITY.

REFER TO AD-101 BUILDING DEMOLITION PLAN FOR FURTHER REQUIREMENTS.

LEGEND

01 EXISTING SIAMESE HOSE BIBB.

DN

DN

UP

02 DEMOLISH EXISTING COLD WATER PIPING FROM MAIN TO EXISTING EYEWASH.

03 EXISTING HOSE BIBB WITH HOSE ON ROLL TO REMAIN.119

GARAGE

WORKSHOP

CLOSET

BREAK RM

BREAK RM

MECH

HALL

WOMEN

MEN

OFFICE

LOBBY

VEST

STORAGE

EX. WALL

HYDRANT

3/4"

EX. 2"

WATER

SERVICE

2"

3/4" 1/2"

2" 1.5

3/4"

2" 3/ 4"

X X

X X

X

X

X X

EX.

BFP

PHASE IIPHASE III

PHASE IIPHASE III

0 2 4 8 12

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2018, TIER4 DESIGN, LLC.

Walker Federal Services, LLC

FACILITY RENOVATION,

IMPROVEMENTS, AND

REPAIRS

BATH NATIONAL CEMETERY

803IC3015

TDF MLP

JUNE 5, 2020

FINAL CONSTRUCTION DOCUMENTS

PLUMBING DEMOLITION

WATER PLANS

PD-102

LEGEND

1. ALL EXISTING SANITARY PIPING WITH THE EXISTING BUILDING (PHASE III

AREA) IS BURIED BELOW A SLAB ON GRADE.

2. NO SERVICE OUTAGES ARE PERMITTED DURING NORMAL BUSINESS HOURS.

COORDINATE ALL OUTAGES WITH COR NOT LESS THAN 7 DAYS IN ADVANCE.

SIMILARLY, COORDINATE ALL WORK THAT OCCURS WITHIN THE OCCUPIED

BUILDING (EVEN IF IT DOES NOT INVOLVE AN OUTAGE) WITH THE COR NOT

LESS THAN 7 DAYS IN ADVANCE.

3. ALL NEW SANITARY WORK WITHIN THE EXISTING BUILDING (PHASE III)

INCLUDES A REQUIREMENT TO CUT THE EXISTING SLAB ON GRADE FOR THE

NEW SANITARY LINES. (FOR PHASE II WORK, THE SLAB IS NEW - INSTALL PHASE

II SANITARY PIPE BEFORE SLAB-POUR).

DN

DN

DN

UP

GARAGE

WORKSHOP

121a

CLOSET

BREAK RM

MECHNICAL

HALL

WOMEN

MEN

LOCKERS

DIRECTOR

OFFICE

IT CLOSET

OPEN OFFICE

RESTROOM

RESTROOM

VESTIBULE

STORAGE

MULTI-USE

FILES

LOBBY

FOREMAN

117a

CLOSET

OFFICE GALLEY

MAINT. GALLEY

CAPPED FORMER CONNECTION TO SINK.

EXISTING 2" VTR TO REMAIN.

NEW 2" VTR.

04 PROVIDE TRAP GUARD WITH FLOOR DRAIN.

1 NEW WORK FLOOR PLAN - ADMINISTRATIVE BUILDING

SCALE: 1/4" = 1'-0"

2 SANITARY RISER DIAGRAMS - ADMINISTRATIVE BUILDING

NO SCALE

1ST FLOOR

ROOF

1ST FLOOR

ROOF

EX. FD

EX. CO

3" 4"

SK-1

3"

SK-1

EX. SK

(116)

EX. UR

(116)

EX. 2" VTR EX. 2" VTR

WC-1

(102)

3"

1.

5"

EX. FD

(118)

LV-1

(102)

EX. SK

(115)

SK-1

(113)

EX. 4"

EX. SK

(119)

03 EX. WC

(115)

EX. WC

(116)

EX. 4"

2" 1.

5"

FD-1

(103)

FD-1

(102)

1.

5"

2"

LV-1

(103)

1.

5"

2"

SK-1

(107)

1.

5"

2"

WC-1

(103)

3" 2"

2" VTR EX. 2" VTR

EX. FD

(122)

EX. FD

4"

4"

1.5"

2"

(119)EX. CO

EX. 4"

3"

2" 2"

3"

2"

EX

. 1

.5

EX

. 1

.5

EX. 2"

EX

. 2

EX. 2"

EX

. 1

.5

EX

. 1

.5

EX

. 1

.5

EX. 3"

EX. 2"

EX

. 2

EX. 2"

WC-1

FD-1

WC-1

LV-1

FD-1

LV-1

SK-2

1.5"

2"

PHASE IIPHASE III

05 PERFORM CONNECTION TO EXISTING SANITARY OUTSIDE NORMAL BUSINESS HOURS

UNLESS SPECIFICALLY APPROVED OTHERWISE BY THE COR.

(SLAB ON GRADE)(SLAB ON GRADE)

CEILINGROOF

CO

COCO

CO

CO

CO

PHASE III

PHASE II

PH

AS

E I

PH

AS

E I

PHASE I

PHASE III

PHASE I

PHASE II

INSTALL THIS WORK IN PHASE I TO MAKE ROOM FOR THE INCOMING SIDEWALK. SEE

PD-101 FOR ADDITIONAL PHASE-I DEMO WORK. COORDINATE SERVICE OUTAGE PER

NOTES ON THIS SHEET.

PHASING

PA

PROVIDE SEALED CAP AT THIS LOCATION AT THE END OF PHASE I. UNSEAL AND

CONTINUE PIPING WHEN PHASE II COMMENCES.

PB

PA

PA

PA PA

PB

0 2 4 8 12

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2018, TIER4 DESIGN, LLC.

Walker Federal Services, LLC

FACILITY RENOVATION,

IMPROVEMENTS, AND

REPAIRS

BATH NATIONAL CEMETERY

803IC3015

TDF MLP

JUNE 5, 2020

FINAL CONSTRUCTION DOCUMENTS

PLUMBING

SANITARY PLANS

PP-101

PHASING

LEGEND

DN

DN

DN

UP

GARAGE

WORKSHOP

121a

CLOSET

BREAK RM

MECHNICAL

HALL

WOMEN

MEN

LOCKERS

DIRECTOR

OFFICE

IT CLOSET

OPEN OFFICE

RESTROOM

RESTROOM

VESTIBULE

STORAGE

MULTI-USE

FILES

LOBBY

FOREMAN

117a

CLOSET

OFFICE GALLEY

MAINT. GALLEY

EXISTING ELECTRIC WATER HEATER. NEW P/T VALVE AND EXPANSION TANK TO BE ADDED.

2 DOMESTIC WATER RISER DIAGRAMS - ADMINISTRATIVE BLDG

NO SCALE

1 NEW WORK FLOOR PLAN - ADMINISTRATIVE BUILDING

SCALE: 1/4" = 1'-0"

1ST FLOOR

ROOF

1ST FLOOR

ROOF

EX. WALL

HYDRANT

3/4"

EX. 2"

WATER

SERVICE

2"

3/4" 1/2"

1.5

2" 3/ 4"

EX.

BFP

02 EXISTING SIAMESE HOSE BIBB TO REMAIN.

03 PROVIDE NEW ANSI Z358.1 (OR APPROVED EQUAL) COMPLIANT TEPID WATER

MIXING VALVE, MOUNTED AT 42" AFF. CONNECT 1/2" CW AND 1/2" HW TO VALVE,

WITH A 1/2" TEPID WATER OUTPUT PIPE FOR THE EXISTING EMERGENCY EYEWASH.

3/4"

1/ 2"

1/ 2"

WC-1

WC-1

LV-1

LV-11.2

5"

1.25"

1/2"

SK-1

3/4"1.5"

1/2"

SK-1

HWR

1/2"

3/4"

3/4"

EX. 2" CW

FROM STREET

1/2"1"1/2"

EX. UR LV-1

EX.

BFP EX.

WH (103)

1/2"

LV-1

(102)

1/2" 1.25"

WC-1(107)

(102)

1/2"

(113)

SK-1 SK-1EX. SK

3/4"

EX. LVEX. LV

(119) (116) (115) (116)

1.5"

EX. WC

(115)

EX. WC

(116) 02EX. WALL

HYDRANT

(120)

EX. HOSE

BIBB

(122)

EX.

FRIDGE

(121)

EX. EYE

WASH

(122)

EX. ICE

MAKER

(121)

1/2"

HWR

EX. 3/4" EX. 3/4" EX. 3/4"

EX. 2" EX. 2" EX. 3/4"

1/2"3/8"1/2"1/2"

3/4"

3/4" 1.5"

3/4"

1.25"

WC-1

(103)

PHASE IIPHASE III

PHASE IIPHASE III

PA PIPES THAT ARE DESIGNATED AS NEW WORK (THICK LINEWEIGHT) IN THIS ZONE MUST

BE DONE DURING PHASE II. PERFORM THIS PORTION OF THE WORK OUTSIDE NORMAL

BUSINESS HOURS UNLESS SPECIFICALLY APPROVED OTHERWISE BY THE COR. THE

EXISTING PIPES (THINNER LINEWEIGHT) WILL BE EXISTING TO REMAIN.

PB THIS SINK (SK-1) WILL BE INSTALLED DURING PHASE III. THEREFORE, THE

HOT AND COLD WATER CONNECTING PIPES WILL ALSO BE INSTALLED DURING

PHASE III.

PA

PB

3/4"

SK-2

(118)

1/2"

REFR.

(119)

04 PIPING GOING THROUGH 2-HR RATED FIRE WALL. PROVIDE FIRE SLEEVE/FIRE CAULK

TO MATCH RATING.

(SLAB ON GRADE)(SLAB ON GRADE)

CEILINGCEILING

NOTES

1. NO SERVICE OUTAGES ARE PERMITTED DURING NORMAL BUSINESS HOURS.

COORDINATE ALL OUTAGES WITH COR NOT LESS THAN 7 DAYS IN ADVANCE.

SIMILARLY, COORDINATE ALL WORK THAT OCCURS WITHIN THE OCCUPIED BUILDING

(EVEN IF IT DOES NOT INVOLVE AN OUTAGE) WITH THE COR NOT LESS THAN 7 DAYS

IN ADVANCE.

2. INSTALL ALL DOMESTIC WATER PIPING SUCH THAT THE PIPING IS LAID ON TOP OF

THE ATTIC JOIST, SUCH THAT THE ATTIC BATT INSULATION IS SEVERAL INCHES ABOVE

THE PIPING, IN ORDER TO PREVENT A POSSIBILITY OF EXPOSURE TO FREEZING

CONDITIONS. SIMILARLY, INSTALL ALL DOMESTIC WATER PIPING THAT IS IN

EXTERNAL WALLS (RESTROOMS 102, 103) SUCH THAT THE PIPING IS ON THE

INNERMOST PORTION OF THE WALL. REPORT ANY DEVIATIONS FROM THESE

REQUIREMENT TO THE COR.

PHASE I

NO NEW DOMESTIC

PLUMBING WORK IS

REQUIRED FOR

PHASE I.

0 2 4 8 12

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2018, TIER4 DESIGN, LLC.

Walker Federal Services, LLC

FACILITY RENOVATION,

IMPROVEMENTS, AND

REPAIRS

BATH NATIONAL CEMETERY

803IC3015

TDF MLP

JUNE 5, 2020

FINAL CONSTRUCTION DOCUMENTS

PLUMBING

WATER PLANS

PP-102

A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2018, TIER4 DESIGN, LLC.

Walker Federal Services, LLC

FACILITY RENOVATION,

IMPROVEMENTS, AND

REPAIRS

BATH NATIONAL CEMETERY

803IC3015

TDF MLP

JUNE 5, 2020

FINAL CONSTRUCTION DOCUMENTS

PP-201

PLUMBING SCHEDULES

STRUCTURAL GENERAL

S-001 93Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2020, Walker Federal Services, LLC

Walker Federal Services, LLC

FACILITY RENOVATION,

IMPROVEMENTS, AND

REPAIRS

BATH NATIONAL CEMETERY

803IC3015

DAB CAD

JUNE 5, 2020

H.F. LENZ COMPANY, P.C.

1407 Scalp Avenue, Johnstown, PA 15904 Phone: 814-269-9300

FAX: 814-269-9301

© COPYRIGHT 2019, H.F. LENZ COMPANY, P.C.

N C A

ATIONAL

EMETERY

DMINISTRATION

N C A

ATIONAL

EMETERY

DMINISTRATION

STRUCTURAL GENERAL

NOTES AND LOADING

S-002 94Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2020, Walker Federal Services, LLC

Walker Federal Services, LLC

FACILITY RENOVATION,

IMPROVEMENTS, AND

REPAIRS

BATH NATIONAL CEMETERY

803IC3015

DAB CAD

JUNE 5, 2020

H.F. LENZ COMPANY, P.C.

1407 Scalp Avenue, Johnstown, PA 15904 Phone: 814-269-9300

FAX: 814-269-9301

© COPYRIGHT 2019, H.F. LENZ COMPANY, P.C.

N C A

ATIONAL

EMETERY

DMINISTRATION

N C A

ATIONAL

EMETERY

DMINISTRATION

File details come from the government source that posted it. Updated .