P09 Corrected OR_ARCH_AC103 - Bldg 2 2nd FLOOR AREA B REFLECTED CEILING PLAN - 1 page.pdf
PDF 475 KB Posted
- Attached to
- Z2DA--Construct Surgical Suite Addition P/N: 657-501 Federal contract opportunity
- Solicitation number
- 36C25520R0040-0001
About this file
This reflected ceiling plan drawing and related federal contract opportunity solicitation provide details for renovating and upgrading operating suites at the Marion VA Medical Center in Marion, Illinois. The reflected ceiling plan drawing shows the layout and design of the new and replacement ceiling systems for various rooms in Building 02 on the second floor, including operating rooms, corridors, scrub stations, and other clinical areas. The related solicitation seeks offers for the construction of a surgical suite addition with the project number 657-501, issued by the Department of Veterans Affairs Veterans Health Administration VISN 15. The solicitation number is 36C25520R0040-0001 and identifies the opportunity type as a solicitation. No other salient details are provided in the documents.
View the file
Other files for this federal contract opportunity
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STAIR
S2-02
OR
CORRIDOR
C204-2
CORRIDOR
205-02
OR
STERILE CORE
CORRIDOR
C201-02
SCRUB STATION
247A
ALCOVE
249A
SCRUB STATION
249B
SCRUB STATION
250A
CHASE
C202-57
9' - 0"
10' - 0"
10' - 0"
9' - 0"
8' - 0"
8' - 0"8' - 0"
AC102
Sim
AC102
Sim
8' - 0"
AC102
Sim
AC102
Sim
10' - 0"
OR
9' - 0"
9' - 0"
9' - 0"
9' - 0"
IMMED. STER.
OPERATING ROOM
BOOMS
OPERATING ROOM
BOOMS
OPERATING ROOM
BOOMS
AFTER REMOVAL OF TEMPORARY
PARTITION/CONSTRUCTION BARRIER, MODIFY
EXISTING CORRIDOR CEILING SYSTEM (TILE AND
GRID) AS REQUIRED TO INSTALL NEW CEILING AS
INDICATED. REPLACE ANY PORTION OF CEILING
DAMAGED DURING RENOVATION TO MATCH
EXISTING.
PROVIDE NEW CEILING SYSTEM (TILE AND GRID) AS
INDICATED. TIE-IN TO EXISTING CEILING SYSTEM
WHERE REMOVAL IS NOT REQUIRED. MATCH
EXISTING CEILING GRID AND TILE (MATERIALS AND
LAYOUT). PROVIDE SEAMLESS TRANSITION BETWEEN
NEW AND EXISTING.
REFLECTED CEILING
PLAN KEYED NOTES
1.
2.
LEGEND: REFLECTED
CEILING PLAN
2x2 ACOUSTICAL CEILING TILE
GYPSUM BOARD CEILING
2x4 LIGHT FIXTURE
PENDANT LIGHT FIXTURE
AIR TERMINAL
RETURN AIR GRILLE
SUPPLY AIR
EXHAUST AIR
CUBICLE CURTAIN TRACKS
CEILING HEIGHT
CIRCULAR DOWNLIGHT
SURGICAL LIGHTS
CEILING MOUNTED DUAL MONITOR
24"X24" ACCESS PANEL
PATIENT LIFT
EXIT SIGN
X' - X"
LIFE SAFETY LEGEND:
NEW 2-HR FIRE BARRIER
EXISTING 2-HR FIRE/SMOKE BARRIER
NEW SMOKE PARTITION
EXIT SIGN
TRAVEL DISTANCE
FIRE EXTINGUISHER CABINET
E
F.E.C.
Engineers Architects
Revisions: Date
Drawing Title
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg. of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
THE ROOM NUMBERING SEQUENCE IS FOR
CONSTRUCTION IDENTIFICATION ONLY. FINAL ROOM
NUMBERING SHALL BE CORRELATED WITH CURRENT
BAS IDENTIFICATION POINTS THAT ARE NOT BEING USED
DUE TO DEMOLITION. FINAL ROOM NUMBERING AND
SIGNAGE SHALL EB APPROVED BY VA STAFF ON
SITE
N
T
C E
I L
TA
S SHEILA
001-016606
CD A R
S E
LYNN
T C
H I
T E
ILOF I L
E NO
I S
EXPIRES 11-30-20
HENSLEY
BAYSINGER
/1
/2
:1
:2
P
M
AC103
BUILDING 02 SECOND FLOOR AREA 'B'
REFLECTED CEILING PLAN
12 28ZC
RELOCATE AND UPGRADE
OPERATING SUITES -
MARION, IL
MARION VAMC
MARION, IL 62959
11/13/2019
BID DOCUMENTS
657-501
MM
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
2A 2B
1/4" = 1'-0"
BUILDING 02 SECOND FLOOR AREA 'B' REFLECTED CEILING PLAN
N