NEHI_Buildings_3_6_19_&_28_Roof_ACM_Survey_Report.pdf
PDF 9 MB Posted
- Attached to
- Reroof Buildings 3, 6, 19 and 28
- Solicitation number
- 25-CR-054
- Issued by
- Pinellas County, Florida
About this file
This document is a National Emissions Standards for Hazardous Air Pollutants (NESHAP) Renovation Survey report prepared by John Smyth, a Licensed Asbestos Consultant for Pinellas County Schools, focusing on the roof areas of Buildings 3, 6, 19, and 28 at Northeast High School in St. Petersburg, Florida. Conducted on May 8, 2024, the survey involved collecting 40 bulk samples from 14 homogeneous areas across the buildings to test for the presence of asbestos-containing materials (ACM) using polarized light microscopy. The survey was performed in accordance with EPA NESHAP and AHERA sampling protocols, with the primary objective of determining the condition and quantity of suspect ACM that might be impacted during planned renovation activities.
The laboratory analysis, performed by Arrowhead Technologies LLC, revealed that no asbestos was detected in any of the building materials tested. The survey encompassed various roof components including rolled mineral roofing with asphalt, Silver Veral roof membrane, caulking, white roof mastic, black roof cement, and roof pitch. The report emphasizes that while this was a limited survey focusing on specific roof areas, any additional suspect ACM discovered during renovation activities should be considered asbestos-containing until proven otherwise through laboratory analysis. The survey is part of the preparatory work for a comprehensive roof replacement project at the high school, ensuring environmental safety and regulatory compliance before the renovation begins.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pinellas County Schools NESHAP Renovation Survey Northeast High School Buildings 3, 6, 19, & 28 Roof ACM Survey 5500 16th Street North St. Petersburg, Pinellas County, Florida i
Northeast High School 5500 16th Street North
Buildings 3, 6, 19, & 28 Roof ACM Renovation Survey
Project No. PCSB-2024-006
Prepared for:
Mr. Timothy F. Caughey, CIH, MPH General Manager Environmental Control
Pinellas County Schools (PCSB) Walter Pownall Service Center
11111 Belcher Road South Largo, FL 33773
Issue Date: May 10, 2024
John C. Smyth, PhD, CIH Licensed Asbestos Consultant Signature Florida License No. AX91
Prepared by:
John Smyth LAC AX91 1497 Main Street, Unit 276 Dunedin, Florida 34698 Phone: (727) 365-5539 ii
TABLE OF CONTENTS
1. INTRODUCTION
2. ASBESTOS FACILITY SURVEY
2.1 SURVEY PURPOSE AND PROCEDURES
2.2 ASBESTOS SURVEY METHODOLOGY
2.3 FACILITY DESCRIPTION
2.4 LABORATORY AND SURVEY RESULTS
3. CONCLUSIONS AND RECOMMENDATIONS
3.1 CONCLUSIONS
3.2 RECOMMENDATIONS
4. LIMITATIONS
APPENDICES
APPENDIX A PHOTOGRAPHIC DOCUMENTATION
APPENDIX B ASBESTOS LABORATORY REPORT AND CHAIN OF
CUSTODY FORM
APPENDIX C PERSONNEL CERTIFICATIONS
iii
LIST OF TABLES
TABLE 1. ASBESTOS SURVEY AND ASSESSMENT FORM
1. INTRODUCTION
Mr. John Smyth, Florida-Licensed Asbestos Consultant AX91 has completed a U.S.
Environmental Protection Agency (EPA) National Emissions Standards for Hazardous Air
Pollutants (NESHAP) renovation survey of suspect asbestos-containing materials (ACMs) at the Northeast High School located at 5500 16th Street North in St, Petersburg, Florida.
The asbestos survey was limited to the Building 3, 6, 19, and 28 main roofs.
On May 8, 2024 Mr. Smyth conducted a NESHAP renovation survey and collected bulk samples of suspect ACM for laboratory analysis to determine asbestos content and type using polarized light microscopy (PLM). Forty (40) bulk samples of suspect ACM for fourteen (14) Homogeneous Areas were collected for laboratory analysis.
No asbestos was detected in any of the building materials tested.
The following sections discuss the asbestos survey assessment purpose, procedures, methodology, conclusions, and recommendations.
2. ASBESTOS FACILITY SURVEY
2.1 SURVEY PURPOSE AND PROCEDURES
Mr. Smyth conducted a renovation asbestos survey of suspect ACM in the roof areas of the subject structures. The objective of the survey was to determine the condition and quantity of the suspect ACM that will be impacted during renovation activities, in order to comply with the Environmental Protection Agency (EPA) Asbestos National Emission Standard for
Hazardous Air Pollutants (NESHAP) requirements and the requirements of the
Occupational Safety and Health Administration (OSHA).
The survey was performed in general accordance with the EPA NESHAP survey requirements and using the EPA Asbestos Hazard Emergency Response Act (AHERA) sampling protocols to determine the number of bulk samples collected and to comply with
OSHA regulations governing asbestos related activities.
The survey was performed by Mr. John Smyth, EPA AHERA accredited asbestos inspector
(see Appendix C for asbestos certifications), on May 8, 2024 on representative suspect building materials to investigate and/or determine the location, quantity, type, condition and potential for damage of suspect friable and non-friable ACM. EPA identifies friable materials as those that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Consideration was also given to materials that could be reduced to powder by the forces (e.g., cutting and grinding) expected to act upon the suspect ACM during renovation activities. The survey activities represent Mr. Smyth’s understanding of the locations and materials that will potentially be impacted in the structure.
The inspector determined the present condition of the suspect ACM and classified it into one of three (3) categories: good, fair (AHERA Damaged), or poor (AHERA Significantly Damaged).
Criteria for determining the Present Condition classifications are:
A. ACM is classified in good condition if it shows no visible damage or deterioration.
B. Asbestos-containing surfacing or miscellaneous materials are classified in fair condition if the damage is less than 10% overall (if the damage is evenly distributed) or less than 25% (if the damage is localized).
C. Asbestos-containing thermal system insulation materials are classified in fair condition if there are missing jackets, water stains, or insulation damage on less than 10% of tanks, vessels, pipe runs and/or risers (if the damage is evenly distributed) or on less than 25% (if the damage is localized).
D. Asbestos-containing surfacing or miscellaneous materials are classified as poor if 10% or more of the overall surface is damaged (if damage is evenly distributed) or if the damage is localized in an area representing 25% or more of the total material. Damages in this category typically would include surface crumbling or blistering, material hanging, delamination or showing other evidence of adhesive failure, water stains, gouges, vandalism, or other damages.
E. Asbestos-containing thermal system insulation materials are classified in poor condition if jackets are generally missing or the insulation is crushed, gouged, punctured, etc., on 10% or more of tanks, vessels, pipe runs and/or risers (if the damage is evenly distributed) or 25% or more (if the damage is localized).
Forty samples of suspect ACM were collected from the building and submitted for analysis to a National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory.
Table 1 presents a description of the samples collected for this current survey.
Photographic documentation of select sample locations was also obtained and is presented in Appendix A of this report.
2.2 ASBESTOS SURVEY METHODOLOGY
The bulk samples of suspect ACM collected were analyzed by a laboratory accredited by
NVLAP (NVLAP ID# 200703-0) using PLM (EPA 600/R-93/116). This methodology identifies the quantity and type of asbestos, if any, in the sample being analyzed. Any material containing more than one percent (> 1 percent) asbestos is an ACM according to the EPA regulations (Chapter 40 Code of Federal Regulations [CFR] Part 763) and OSHA
29 CFR 1926.1101 and 29 CFR 1910.1001.
2.3 FACILITY DESCRIPTION
BUILDING 3 ROOF
The majority field for the Building 3 roof is gray rolled mineral roofing with asphalt.
Silver Veral roof membrane is present at select roof penetration locations. Caulking is present on metal flashing.
BUILDING 6 ROOF
The majority field for the Building 4 roof is gray rolled mineral roofing with asphalt.
Silver Veral roof membrane is present at select roof edge locations. There are areas of white roof mastic or coating present on select roof corners. A gray roof mastic is present on select metal flashing and roof penetrations. Caulking is present on metal flashing.
BUILDING 19 ROOF
The majority field for the Building 19 roof is gray rolled mineral roofing with asphalt.
There are areas of white roof mastic or coating present on select portions of the roof.
Caulking is present on metal flashing. Black roof cement is present on various roof patch areas.
BUILDING 28 ROOF
The majority field for the Building 28 roof is gray rolled mineral roofing with asphalt.
Caulking is present on metal flashing. Roof pitch is present in pitch pots at select roof penetrations.
Please note that this was a limited survey, meaning that survey activities were restricted to the building roofs that will be affected by the planned renovation activities.
Any other suspect ACM found in the roof areas during renovation activities, not specifically identified in this report, must be considered to be ACM until determined to be non-ACM by an LAC and laboratory analysis.
2.4 LABORATORY AND SURVEY RESULTS
No asbestos was detected in any of the building materials tested. Table 1 is a summary of the current asbestos survey and assessment results.
Appendix B contains the asbestos laboratory report.
3. CONCLUSIONS AND RECOMMENDATIONS
3.1 CONCLUSIONS
Mr. Smyth has completed the NESHAP renovation asbestos survey of the roofs of Buildings
3, 6, 19, and 28 at the Northeast High School property located in St. Petersburg, Florida.
Forty (40) bulk samples of suspect ACM for fourteen (14) Homogeneous Areas were collected on May 8, 2024 and submitted for standard turn-around laboratory analysis of asbestos content using PLM methodology.
During this survey no asbestos was detected in any of the building materials tested.
Photographic documentation of select sample locations is presented in Appendix A.
Appendix B contains the asbestos laboratory report.
3.2 RECOMMENDATIONS
It is the understanding of Mr. Smyth that the roof areas surveyed will be renovated in near future.
Should additional building materials be discovered during renovation activities, these materials should be assumed to be ACM until laboratory sample analysis can be conducted and treated accordingly.
4. LIMITATIONS
All of the professional opinions presented in this NESHAP asbestos renovation survey report are based solely on the scope of work conducted and sources referred to in this report.
The data presented by Mr. Smyth in this report were collected and analyzed using generally accepted industry methods and practices at the time the report was generated. This report represents the conditions, locations and materials that were observed at the time the fieldwork was performed.
TABLE
TABLE 1. ASBESTOS SURVEY AND ASSESSMENT FORM
Building Name: Northeast High School Roof Survey Survey Date: May 8, 2024 Project No.: PCSB-2024-006 *Please note that this was a limited asbestos survey.
Sample No.
Homog Area Functional Space* Condition
Damage Potential Friable Y/N Asbestos Type-%
EPA NESHAP
Classification
BUILDING THREE
01 - 05 01 Main Roof Good High No NAO N/A 06, 07 02 Roof Penetrations Good High No NAO N/A 08, 09 03 Metal Flashing Good High No NAO N/A
BUILDING SIX
10 - 15 04 Main Roof Good High No NAO N/A 16, 17 05 Metal Flashing Good High No NAO N/A 18, 19 06 Coated Roof Area Good High No NAO N/A 20, 21 07 Roof Edge Good High No NAO N/A
22 - 25 08 Main Roof Good High No NAO N/A 26, 27 09 Metal Flashing Good High No NAO N/A 28, 29 10 Coated Roof Area Good High No NAO N/A 30, 31 11 Patched Areas Good High No NAO N/A
32 - 36 12 Main Roof Good High No NAO N/A 37, 38 13 Metal Flashing Good High No NAO N/A 39, 40 14 Pitch Pots at Roof Penetrations Good High No NAO N/A
Notes for Table 1:
NAO: N/A: Not Applicable Cat. I NF USEPA NESHAP Classification Category I Non-Friable Asbestos-Containing Material Cat. II NF USEPA NESHAP Classification Category II Non-Friable Asbestos-Containing Material
RACM:
%: PACM:
*This is not the sample location. To determine the sample location of each ACM, please see the attached laboratory report and/or chain-of-custody.
The damage potential is based on planned renovation activities.
No Asbestos Observed
USEPA NESHAP Classification Regulated Asbestos-Containing Material Presumed Asbestos-Containing Material Percent
Material
Rolled Mineral Roof and Asphalt Silver Veral Roof Membrane
Rolled Mineral Roof and Asphalt Caulking
Roof Pitch
Caulking
Rolled Mineral Roof and Asphalt
Black Roof Cement
BUILDING NINETEEN
Caulking
Caulking White Roof Mastic
White Roof Mastic Silver Veral Roof Membrane
BUILDING TWENTY-EIGHT
Rolled Mineral Roof and Asphalt
APPENDIX A
PHOTOGRAPHIC DOCUMENTATION
Northeast High School B3, B6, B28, & B19 Roof ACM Survey
Photograph 01 – Northeast High School Photograph 02 – Building 3 HA 01 – Rolled Mineral Roof and Asphalt
Photograph 03 – Building 3 HA 02 – Silver Veral Roof Membrane Photograph 04 – Building 3 HA 03 – Caulking
Photograph 05 – Building 6 HA 04 – Rolled Mineral Roof and Asphalt Photograph 06 – Building 6 HA 05 – Caulking
Photograph 07 – Building 6 HA 06 – White Roof MasƟc Photograph 08 – Building 6 HA 07 – Silver Veral Roof Membrane
Photograph 09 – Building 28 HA 08 – Rolled Mineral Roof and Asphalt Photograph 10 – Building 28 HA 09 – Caulking
Photograph 11 – Building 28 HA 10 – White Roof MasƟc Photograph 12 – Building 28 HA 11 – Black Roof Cement
Photograph 13 – Building 19 HA 12 – Rolled Mineral Roof and Asphalt Photograph 14 – Building 19 HA 13 – Caulking
Photograph 15 – Building 19 HA 14 – Roof Pitch
APPENDIX B
ASBESTOS LABORATORY REPORT AND CHAIN OF
CUSTODY
PLM REPORT SUMMARY
3151 San Bernadino St.
Clearwater, Florida 33759
NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com
Client : Smyth Consulting Group, LLC Lab Set No. : 013110
Project : Northeast High Four Roofs 24-13110AT Job No. :
PCSB-2024-006Client Project No.: Report Date : 5/10/2024
Identification : Asbestos, Bulk Sample Analysis Sample Date : 5/8/2024
Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 1 of 8App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116
On 5/ 8/2024, forty (40) bulk material samples were submitted by John Smyth for asbestos analysis by PLM/DS.
Copies of Bulk Sample Analysis sheets are attached; additional information may be found therein. The results are summarized below:
Asbestos ContentSample Description / LocationLab Sample No.
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA1-1013110-001 None Detected-Black TarBldg 3 None Detected-Black Roof Felt None Detected-Gray Gypsum Material
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA1-2013110-002 None Detected-Black TarBldg 3 None Detected-Black Roof Felt None Detected-Gray Gypsum Material
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA1-3013110-003 None Detected-Black TarBldg 3 None Detected-Black Roof Felt None Detected-Gray Gypsum Material
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA1-4013110-004 None Detected-Black TarBldg 3 None Detected-Black Roof Felt None Detected-Gray Gypsum Material
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA1-5013110-005 None Detected-Black TarBldg 3 None Detected-Black Roof Felt None Detected-Gray Gypsum Material
These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Arrowhead utilizes CVAE on a routine basis and does not include point counting unless specifically requested.
The results may not be reproduced except in full.
PLM Report Summary - Revision 4 - 08/04/2022- Issuing Authority: Monte Hall, PG mailto:mhall005@tampabay.rr
Clearwater, Florida 33759
NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com
Client : Smyth Consulting Group, LLC Lab Set No. : 013110
Project : Northeast High Four Roofs 24-13110AT Job No. :
PCSB-2024-006Client Project No.: Report Date : 5/10/2024
Identification : Asbestos, Bulk Sample Analysis Sample Date : 5/8/2024
Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 2 of 8App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116
On 5/ 8/2024, forty (40) bulk material samples were submitted by John Smyth for asbestos analysis by PLM/DS.
Copies of Bulk Sample Analysis sheets are attached; additional information may be found therein. The results are summarized below:
Asbestos ContentSample Description / LocationLab Sample No.
None Detected-Silver CoverSilver Veral Roof Membrane HA2-6013110-006 None Detected-Black Roof MembraneBldg 3
None Detected-Silver CoverSilver Veral Roof Membrane HA2-7013110-007 None Detected-Black Roof MembraneBldg 3
None Detected-White CaulkingCaulking HA3-8013110-008 Bldg 3
None Detected-White CaulkingCaulking HA3-9013110-009 Bldg 3
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA4-10013110-010 None Detected-Black TarBldg 6 None Detected-Black Roof Felt None Detected-Brown Insulation
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA4-11013110-011 None Detected-Black TarBldg 6 None Detected-Black Roof Felt None Detected-Brown Insulation
These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Arrowhead utilizes CVAE on a routine basis and does not include point counting unless specifically requested.
The results may not be reproduced except in full.
Clearwater, Florida 33759
NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com
Client : Smyth Consulting Group, LLC Lab Set No. : 013110
Project : Northeast High Four Roofs 24-13110AT Job No. :
PCSB-2024-006Client Project No.: Report Date : 5/10/2024
Identification : Asbestos, Bulk Sample Analysis Sample Date : 5/8/2024
Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 3 of 8App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116
On 5/ 8/2024, forty (40) bulk material samples were submitted by John Smyth for asbestos analysis by PLM/DS.
Copies of Bulk Sample Analysis sheets are attached; additional information may be found therein. The results are summarized below:
Asbestos ContentSample Description / LocationLab Sample No.
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA4-12013110-012 None Detected-Black TarBldg 6 None Detected-Black Roof Felt None Detected-Brown Insulation
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA4-13013110-013 None Detected-Black TarBldg 6 None Detected-Black Roof Felt None Detected-Brown Insulation
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA4-14013110-014 None Detected-Black TarBldg 6 None Detected-Black Roof Felt None Detected-Brown Insulation
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA4-15013110-015 None Detected-Black TarBldg 6 None Detected-Black Roof Felt None Detected-Brown Insulation
None Detected-White CaulkingCaulking HA5-16013110-016 Bldg 6
These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Arrowhead utilizes CVAE on a routine basis and does not include point counting unless specifically requested.
The results may not be reproduced except in full.
Clearwater, Florida 33759
NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com
Client : Smyth Consulting Group, LLC Lab Set No. : 013110
Project : Northeast High Four Roofs 24-13110AT Job No. :
PCSB-2024-006Client Project No.: Report Date : 5/10/2024
Identification : Asbestos, Bulk Sample Analysis Sample Date : 5/8/2024
Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 4 of 8App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116
On 5/ 8/2024, forty (40) bulk material samples were submitted by John Smyth for asbestos analysis by PLM/DS.
Copies of Bulk Sample Analysis sheets are attached; additional information may be found therein. The results are summarized below:
Asbestos ContentSample Description / LocationLab Sample No.
None Detected-White CaulkingCaulking HA5-17013110-017 Bldg 6
None Detected-White MasticWhite Roof Mastic HA6-18013110-018 Bldg 6
None Detected-White MasticWhite Roof Mastic HA6-19013110-019 Bldg 6
None Detected-Silver CoverSilver Veral Roof Membrane HA7-20013110-020 None Detected-Black Roof MembraneBldg 6
None Detected-Silver CoverSilver Veral Roof Membrane HA7-21013110-021 None Detected-Black Roof MembraneBldg 6
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA8-22013110-022 None Detected-Black TarBldg 28 None Detected-Black Roof Felt
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA8-23013110-023 None Detected-Black TarBldg 28 None Detected-Black Roof Felt
These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Arrowhead utilizes CVAE on a routine basis and does not include point counting unless specifically requested.
The results may not be reproduced except in full.
Clearwater, Florida 33759
NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com
Client : Smyth Consulting Group, LLC Lab Set No. : 013110
Project : Northeast High Four Roofs 24-13110AT Job No. :
PCSB-2024-006Client Project No.: Report Date : 5/10/2024
Identification : Asbestos, Bulk Sample Analysis Sample Date : 5/8/2024
Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 5 of 8App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116
On 5/ 8/2024, forty (40) bulk material samples were submitted by John Smyth for asbestos analysis by PLM/DS.
Copies of Bulk Sample Analysis sheets are attached; additional information may be found therein. The results are summarized below:
Asbestos ContentSample Description / LocationLab Sample No.
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA8-24013110-024 None Detected-Black TarBldg 28 None Detected-Black Roof Felt
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA8-25013110-025 None Detected-Black TarBldg 28 None Detected-Black Roof Felt
None Detected-White/Gray CaulkingCaulking HA9-26013110-026 Bldg 28
None Detected-White/Gray CaulkingCaulking HA9-27013110-027 Bldg 28
None Detected-White MasticWhite Roof Mastic HA10-28013110-028 Bldg 28
None Detected-White MasticWhite Roof Mastic HA10-29013110-029 Bldg 28
None Detected-Black Roof CementBlack Roof Cement HA11-30013110-030 Bldg 28
These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Arrowhead utilizes CVAE on a routine basis and does not include point counting unless specifically requested.
The results may not be reproduced except in full.
Clearwater, Florida 33759
NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com
Client : Smyth Consulting Group, LLC Lab Set No. : 013110
Project : Northeast High Four Roofs 24-13110AT Job No. :
PCSB-2024-006Client Project No.: Report Date : 5/10/2024
Identification : Asbestos, Bulk Sample Analysis Sample Date : 5/8/2024
Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 6 of 8App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116
On 5/ 8/2024, forty (40) bulk material samples were submitted by John Smyth for asbestos analysis by PLM/DS.
Copies of Bulk Sample Analysis sheets are attached; additional information may be found therein. The results are summarized below:
Asbestos ContentSample Description / LocationLab Sample No.
None Detected-Black Roof CementBlack Roof Cement HA11-31013110-031 Bldg 28
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA12-32013110-032 None Detected-Black TarBldg 19 None Detected-Black Roof Felt None Detected-Gray Gypsum Material
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA12-33013110-033 None Detected-Black TarBldg 19 None Detected-Black Roof Felt None Detected-Gray Gypsum Material
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA12-34013110-034 None Detected-Black TarBldg 19 None Detected-Black Roof Felt None Detected-Gray Gypsum Material
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA12-35013110-035 None Detected-Black TarBldg 19 None Detected-Black Roof Felt None Detected-Gray Gypsum Material
These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Arrowhead utilizes CVAE on a routine basis and does not include point counting unless specifically requested.
The results may not be reproduced except in full.
Clearwater, Florida 33759
NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com
Client : Smyth Consulting Group, LLC Lab Set No. : 013110
Project : Northeast High Four Roofs 24-13110AT Job No. :
PCSB-2024-006Client Project No.: Report Date : 5/10/2024
Identification : Asbestos, Bulk Sample Analysis Sample Date : 5/8/2024
Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 7 of 8App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116
On 5/ 8/2024, forty (40) bulk material samples were submitted by John Smyth for asbestos analysis by PLM/DS.
Copies of Bulk Sample Analysis sheets are attached; additional information may be found therein. The results are summarized below:
Asbestos ContentSample Description / LocationLab Sample No.
None Detected-Black Roof MembraneRolled Mineral Roof and Asphalt HA12-36013110-036 None Detected-Black TarBldg 19 None Detected-Black Roof Felt None Detected-Gray Gypsum Material
None Detected-White/Gray CaulkingCaulking HA13-37013110-037 Bldg 19
None Detected-White/Gray CaulkingCaulking HA13-38013110-038 Bldg 19
None Detected-Black Roof PitchRoof Pitch HA14-39013110-039 Bldg 19
None Detected-Black Roof PitchRoof Pitch HA14-40013110-040 Bldg 19
These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Arrowhead utilizes CVAE on a routine basis and does not include point counting unless specifically requested.
The results may not be reproduced except in full.
Clearwater, Florida 33759
NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com
Client : Smyth Consulting Group, LLC Lab Set No. : 013110
Project : Northeast High Four Roofs 24-13110AT Job No. :
PCSB-2024-006Client Project No.: Report Date : 5/10/2024
Identification : Asbestos, Bulk Sample Analysis Sample Date : 5/8/2024
Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 8 of 8App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116
SCOPE OF THIS REPORT
These samples were obtained as a part of a building survey; this report is only intended to be used as a part of the survey report issued by the surveyor. This report explains the laboratory analysis and results. The surveyor's report explains the sampling protocol used, when the samples were obtained, the location(s) of the samples, where the materials were observed in the building, quantities of materials observed, condition of the materials and the extent of his/her survey. Sample locations and material descriptions are given by the surveyor on the chain of custody but included here (possibly abbreviated)only as a convenience for the reader.
This report may not be reproduced without written permission of Arrowhead Technologies, LLC and must be reproduced in full.
STATEMENT OF LABORATORY ACCREDITATION
The samples were analyzed in general accordance with the procedures outlined in the Method for the Determinationof Asbestos in Bulk Building Materials, EPA/600/R-93/116,and the Interim Method for the Determinationof Asbestos in Bulk Insulation Samples, EPA 600/M4-82-020. The results of each bulk sample relate only to the material tested as received and the results shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
Floor tile and other resinously bound materials, when analyzed by the EPA method, may yield false negative results because of limitations in separating closely bound fibers and in detecting fibers of small length and diameter. When a definitive result is required, Arrowhead recommendsutilizing alternative methods of identification, including Transmission Electron Microscopy.
Specific questions concerning bulk sample results shall be directed to the Laboratory Director.
Analyst : Ryan Schwegman
Monte Hall, P.G.Laboratory Director :
Florida Registration No. 1658
Approved Signatory :
APPENDIX C
PERSONNEL CERTIFICATIONS
V R E T
Vern Roberts Environmental Training, Inc.
13987 94th Avenue Seminole, FL 33776
727-239-1445
Certifies that
John Smyth
Has satisfactorily completed the requisite training for asbestos accreditation under TSCA TITLE II, EPA Model
Accreditation Plan (40CFR763 E) for the 4-hour Inspector (Survey & Mechanical) Refresher Course on
1/13/2024, and in testimony whereof, we do confer this certificate on 1/13/2024.
Date of Course: 1/13/2024 Expiration Date 1/13/2025
Certificate # 01132401AM
Course # FL49-0006322 Provider # FL49-0003810
INSTRUCTOR
Mobile User
Melanie S. Griffin, SecretaryRon DeSantis, Governor
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
ASBESTOS LICENSING UNIT
THE ASBESTOS CONSULTANT HEREIN IS LICENSED UNDER THE
PROVISIONS OF CHAPTER 469, FLORIDA STATUTES
SMYTH, JOHN CHARLES
Do not alter this document in any form.
BUREAU VERITAS NORTH AMERICA INC
LICENSE NUMBER: AX91
EXPIRATION DATE: NOVEMBER 30, 2024
This is your license. It is unlawful for anyone other than the licensee to use this document.
2700 BAYSHORE BOULEVARD
APT 537
DUNEDIN FL 34698
Always verify licenses online at MyFloridaLicense.com https://www.myfloridalicense.com/LicenseDetail.asp?SID=&id=43c4459509473124e47dd7ff4707b09b
| Smyth John BIR 01132401AM.pdf |
| Instructor |
File details come from the government source that posted it. Updated .