2412-02_Northeast_HS_Roof_A5.4_Addendum_4_06.03.25.pdf

PDF 415 KB Posted

Attached to
Reroof Buildings 3, 6, 19 and 28
Solicitation number
25-CR-054
Issued by
Pinellas County, Florida

About this file

This document is a detailed architectural drawing (Sheet A5.4) for a roof replacement project by Williamson Dacar Associates, Inc. for Pinellas County Schools at Northeast High School, specifically focusing on roof details for Buildings 3, 6, 19, and 28. The drawing provides technical specifications for typical pipe supports, roof edge details, guardrail configurations, and reglet flashing details. The drawing is part of a permit set dated 04/16/25, with an addendum issued on 06/03/25, and includes precise technical specifications for roofing materials, attachment methods, insulation, flashing, and structural components such as pipe guides, galvanized steel pipes, and mounting plates.

The drawing includes specific technical instructions for installation, such as using 0.050 aluminum drip edges, modified bitumen cant strips, new tapered insulation, and stainless steel fasteners. It specifies detailed mounting requirements like #10 x 2 1/4" stainless steel wood screws, 1/4" x 4" stainless steel countersunk tapcons, and guidelines for existing structure preservation. The document emphasizes precise measurements, material specifications, and installation techniques, with notes for contractors to verify existing conditions and notify the architect of any variations. The technical drawing serves as a comprehensive guide for the roof replacement project, ensuring standardized and precise construction methods.

View the file

Other files

File Type Posted
NEHI_Buildings_3_6_19_&_28_Roof_ACM_Survey_Report.pdf PDF
Reroof_Buildings_3_6_19_and_28_Addendum_5_Revision.pdf PDF
Northeast_HS_Building_3_6_19_&_28_Roof_Question_Reponse_06.05.25.pdf PDF
Reroof_Buildings_3_6_19_and_28_Addendum_4_Revision.pdf PDF
00_01_00_Bid_Specifications_Addendum_4_06.03.25.pdf PDF
NE_Pinellas_High_School_Nuclear_Moisture_Survey_Report_1.pdf PDF
099000_Appendix_B__Quality_Control_Inspection_PCS.pdf PDF
2412-02_Northeast_HS_Roof_Replacement_-_Addendum_4_Summary_2025.06.03.pdf PDF
2412-02_Northeast_HS_Roof_A5.2_Addendum_4_06.03.25.pdf PDF
092400_PORTLAND_CEMENT_PLASTER_Addendum_4_06.03.25.pdf PDF
2412-02_Northeast_HS_Roof_A1.3_Addendum_4_06.03.25.pdf PDF
099000_Painting_and_Coatings_Addendum_4_06.03.25.pdf PDF
099000_Appendix_A__Approved_Products_PCS_revised_by_WDA_.pdf PDF
NE_Pinellas_High_School_Nuclear_Moisture_Survey_Report.pdf PDF
Reroof_Buildings_3_6_19_and_28_Addendum_3_Revision.pdf PDF
Pre-bid_sign_in_sheets.pdf PDF
2412-02_PCS_Northeast_HS_Reroof_Bldg_3_6_19_28_PH_4_Permit_BID_Specifications_04.16.25_S&S.pdf PDF
Insurance_Specifications_for_Contractors.pdf PDF
2412-02_PCSB_Northeast_HS_Roof_Permit_Set_Structural_2025.04.16_S&S.pdf PDF
2412-02_PCSB_Northeast_HS_Roof_Permit_Set_Arch_2025.04.16_S&S.pdf PDF
Bid_Protest_Procedure.pdf PDF
Reroof_Buildings_3_6_19_and_28.pdf PDF
2412-02_PCSB_Northeast_HS_Roof_Permit_Set_MEP_2025.04.16_S&S.pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CAP SHEET HEAT

WELDED

BASE SHEET HEAT

WELDED

MODIFIED

ROOF

CEMENT

INSTALL EXTRA

PROTECTION

LAYER

MIRO INDUSTRIES PIPE GUIDES ARE DESIGNED TO

ATTACH TO MIRO INDUSTRIES PIPE SUPPORTS SO AS

TO ALLOW PIPE TO COME OUT OF OR BE DISPLACED

FROM THE PIPE STAND. PIPE GUIDES SHOULD NOT BE

RIGIDLY ATTACHED TO THE ACTUAL PIPE THAT IS

PLACED IN THE PIPE STAND, THUS ALLOWING FOR

EXPANSION AND CONTRACTION TO OCCUR WITHIN THE

PIPE STAND. STRAP MATERIAL IS A .040 ALUMINUM 5052

ALLOW TEMPER H32 ASTM B-209-0. INCLUDED WITH 1.5

AND 3-R PIPE GUIDES ARE #8 STAINLESS STEEL

SCREWS THAT ARE TO BE USED TO MOUNT THROUGH

PRE-PUNCHED HOLDS IN THE STRAP DOWN INTO THE

POLYCARBONATE PIPE SUPPORTS.

NOTE:

1.5" PIPE GUIDE

STRAP.

SEE NOTE

PVC PIPE FROM EQUIPMENT

#8 STAINLESS

STEEL

SCREWS

NEW PIPE STAND BY MICRO

INDUSTRIES, INC. (PILLOW

BLOCK

SUPPORTS MODEL 1.5)

NEW PIPE SPACER BY MICRO INDUSTRIES, INC. (PIPE

SUPPORT ACCESSORIES MODEL 1.5 SPACER) AS NEED TO

HAVE SLOPE IN PIPE. SEE MECH DRAWINGS

EXISTING METAL DECK

V

.I .F

.) 5

0.050 ALUMINUM DRIP

EDGE

1 1/4" x 1 1/4" x 2" MODIFIED

BITUMEN CANT MODEL

DERBICANT

NEW RIGID

INSULATION PER

NEW ROOF PLAN

1/4" SOPRABOARD

EXISTING 2x BLOCKING TO REMAIN. IF BLCOKING IS

DAMAGED REPLACE WITH NEW. EXISTING 3/8" ANCHOR

TO REMAIN. ADD 1/4" x 4" S.S. COUNTERSUNK TAPCONS

INTO CONCRETE BEAM STAGGERED @ 6" O.C.

(CONTRACTOR TO VERIFY EXISTING CONDITIONS

ONCE EXISTING ROOF IS REMOVED. NOTIFY

ARCHITECT IF EXISTING CONDITIONS VARY)

#10 x 2 1/4" S.S. WOOD SCREWS

EXISTING LIGHTWEIGHT

CONCRETE AND METAL DECK

TO REMAIN

1/4" SOPRABOARD TO REMAIN

4"

EXISTING WALL

EXISTING METAL

DECK TO REMAIN

S5.1

1/4"

/2

HORIZ. GALV. STEEL PIPE

WELDED TO VERTICAL PIPE -

ALL ABOUT TYP.

ROOF MOUNTED

GUARDRAIL - SCH. 40 - 2"

⌀ GALV.

HORIZ. GALV. STEEL PIPE

WELDED TO VERTICAL PIPE -

ALL ABOUT TYP.

VERTICAL PIPE TO BE 48"

O.C. MAX. TYP. TO BE

PAINTED WHITE

7" x 7" x 1/4" GALV. STEEL PLATE FULLY

WELDED TO 2" DIA. GALV. PIPE, ALL ABOUT.

7" x 7" x 1/4" PLATE W/ (4) 1/2" THRU BOLT

ANCHORS W/ 1 1/2" WASHERS ON THE

UNDERSIDE OF THE JOISTS

BASE FLASHING

CAP FLASHING

4" MIN. FLANGE

STAINLESS STEEL

WORM GEAR CLAMP

NEW 7" x 7" x 1/4" GALV. STEEL PLATE

FULLY WELDED TO 2" DIA. GALV. PIPE,

ALL ABOUT. 7" x 7" x 1/4" PLATE W/ (4) 1/2"

THRU BOLT ANCHORS W/ 1 1/2"

WASHERS ON THE UNDERSIDE OF THE

JOISTS

/4

E Q

E

Q

M

IN

0.050 ALUMINUM DRIP

EDGE

1 1/4" x 1 1/4" x 2" MODIFIED

BITUMEN CANT MODEL

DERBICANT

NEW TAPERED

INSULATION PER

NEW ROOF PLAN

1/4" SOPRABOARD

#10 x 2 1/4" S.S. WOOD SCREWS

NEW TAPERED INSULATION

PER PLAN

1/4" SOPRABOARD

5"

EXISTING WALL

EXISTING METAL

DECK TO REMAIN

EXISTING METAL DECK TO

REMAIN

NEW MODIFIED BITUMEN

ROOF MEMBRANE TO RUN

UP AND OVER WALL TO

ROOF ABOVE

REPAIR EXISTING STUCCO AS

REQUIRED FOR PROPER

INSTALLATION OF NEW ROOF

MEMBRANE

EXISTING 2x BLOCKING TO REMAIN. IF BLCOKING IS

DAMAGED REPLACE WITH NEW. EXISTING 3/8"

ANCHOR TO REMAIN. ADD 1/4" x 4" S.S.

COUNTERSUNK TAPCONS INTO CONCRETE BEAM

STAGGERED @ 6" O.C.

NEW P.T. 2x BLOCKING ATTACH EACH INDIVIDUAL BLOCKING W/ #10 x 2 1/4" S.S. WOOD SCREWS @ 6"

O.C. STAGGERED

.050 ALUMINUM GRAVEL STOP

NEW 1/4" SOPRABOARD

TWO PIECE WALL REGLET

FLASHING PER DETAIL 1/A5.2

CONTRACTOR TO CUT STUCCO AS

REQUIRED FOR NEW FLASHING TO

BE INSTALLED. REPAIR STUCCO

AND SHEATHING AS REQUIRED

1 1/4" x 1 1/4" x 2" MODIFIED

BITUMEN CANT MODEL

DERBICANT

NEW TAPERED INSULATION

EXISTING METAL DECK TO REMAIN

EXISTING METAL DECK TO REMAIN

NEW TAPERED INSULATION

EXISTING 2x BLOCKING TO REMAIN. IF

BLCOKING IS DAMAGED REPLACE WITH

NEW. EXISTING 3/8" ANCHOR TO

REMAIN. ADD #12 S.S. COUNTERSUNK

TEK SCREWS INTO METAL BELOW

STAGGERED @ 6" O.C.

NEW P.T. 2x BLOCKING ATTACH EACH INDIVIDUAL BLOCKING W/ #10 x 2 1/4"

S.S. WOOD SCREWS @ 6" O.C.

STAGGERED

0.050 ALUMINUM DRIP

EDGE

M

IN

.050 ALUMINUM

GRAVEL STOP

DRAWING TITLE:

SHEET NO.

WDA PROJ. NO:

OWNER PROJ. NO:

SCALE: REFER TO SHEET

ISSUE/REVISION OF DRAWINGS:

ARCHITECT: AA0002541

ENGINEER: EB 0006884

PHASE:

CHECKED:

DRAWN:

T H

IS

D

O C

U M

E N

T C

O N

T A

IN

S

C O

P Y

R

IG

H T

E D

M A

T E

R

IA

L A

N D

T R

A D

E S

E C

R E

T I N

F O

R M

A T

IO

N

B E

L O

N G

IN

G

E X

C L U

S

IV

E L Y

T O

W

IL

L

IA

M S

O N

D A

C A

R A

S S

O C

IA

T

E S

IN

C

A N

Y U

N A

U T

H O

R

IZ

E D

U S

E

D

IS

C L O

S U

R E

D

IS

S

E M

IN

A

T

IO

N O

R D

U P

L

IC

A T

IO

N

O F

A N

Y O

F T

H E

I N

F O

R M

A T

IO

N

C O

N T

A

IN

E D

H E

R E

IN

M

A Y

R E

S U

L T

I N

L

IA

B

IL

IT

Y

U N

D E

R A

P P

L

IC

A B

L E

L A

W S

P R

O F

E S

S

IO

N A

L

T H

E O

D O

R E

J W

IL

L

IA

M S

O N

A R

P

E

/4

/2

:4 :5

A

M

ROOF DETAILS

th

S t.

N S t.

P e te rs b u rg

F

L

A5.4

2412-02

PERMIT SET

N O

R T

H E

A S

T H

IG

H

S C

H O

O L R

O O

F R

E P

L A

C E

M E

N T

B

U

IL

D

IN

G S

Checker

Author

NO. DATE DESCRIPTION

04/16/25 PH4 100% CD PERMIT

1 06/03/25 ADDENDUM #4

1 1/2" = 1'-0"A5.4

1 TYPICAL PIPE SUPPORT

1 1/2" = 1'-0"A5.4

2 ROOF EDGE DETAIL 2 - BUILDING 6

1 1/2" = 1'-0"A5.4

3 TYPICAL GUARDRAIL DETAIL

1 1/2" = 1'-0"A5.4

4 ROOF EDGE DETAIL - BUILDING 19

1 1/2" = 1'-0"A5.4

5 REGLET FLASHING DETAIL - BUILDING 19

Sheets
A5.4 - ROOF DETAILS