2412-02_Northeast_HS_Roof_A5.4_Addendum_4_06.03.25.pdf
PDF 415 KB Posted
- Attached to
- Reroof Buildings 3, 6, 19 and 28
- Solicitation number
- 25-CR-054
- Issued by
- Pinellas County, Florida
About this file
This document is a detailed architectural drawing (Sheet A5.4) for a roof replacement project by Williamson Dacar Associates, Inc. for Pinellas County Schools at Northeast High School, specifically focusing on roof details for Buildings 3, 6, 19, and 28. The drawing provides technical specifications for typical pipe supports, roof edge details, guardrail configurations, and reglet flashing details. The drawing is part of a permit set dated 04/16/25, with an addendum issued on 06/03/25, and includes precise technical specifications for roofing materials, attachment methods, insulation, flashing, and structural components such as pipe guides, galvanized steel pipes, and mounting plates.
The drawing includes specific technical instructions for installation, such as using 0.050 aluminum drip edges, modified bitumen cant strips, new tapered insulation, and stainless steel fasteners. It specifies detailed mounting requirements like #10 x 2 1/4" stainless steel wood screws, 1/4" x 4" stainless steel countersunk tapcons, and guidelines for existing structure preservation. The document emphasizes precise measurements, material specifications, and installation techniques, with notes for contractors to verify existing conditions and notify the architect of any variations. The technical drawing serves as a comprehensive guide for the roof replacement project, ensuring standardized and precise construction methods.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CAP SHEET HEAT
WELDED
BASE SHEET HEAT
WELDED
MODIFIED
ROOF
CEMENT
INSTALL EXTRA
PROTECTION
LAYER
MIRO INDUSTRIES PIPE GUIDES ARE DESIGNED TO
ATTACH TO MIRO INDUSTRIES PIPE SUPPORTS SO AS
TO ALLOW PIPE TO COME OUT OF OR BE DISPLACED
FROM THE PIPE STAND. PIPE GUIDES SHOULD NOT BE
RIGIDLY ATTACHED TO THE ACTUAL PIPE THAT IS
PLACED IN THE PIPE STAND, THUS ALLOWING FOR
EXPANSION AND CONTRACTION TO OCCUR WITHIN THE
PIPE STAND. STRAP MATERIAL IS A .040 ALUMINUM 5052
ALLOW TEMPER H32 ASTM B-209-0. INCLUDED WITH 1.5
AND 3-R PIPE GUIDES ARE #8 STAINLESS STEEL
SCREWS THAT ARE TO BE USED TO MOUNT THROUGH
PRE-PUNCHED HOLDS IN THE STRAP DOWN INTO THE
POLYCARBONATE PIPE SUPPORTS.
NOTE:
1.5" PIPE GUIDE
STRAP.
SEE NOTE
PVC PIPE FROM EQUIPMENT
#8 STAINLESS
STEEL
SCREWS
NEW PIPE STAND BY MICRO
INDUSTRIES, INC. (PILLOW
BLOCK
SUPPORTS MODEL 1.5)
NEW PIPE SPACER BY MICRO INDUSTRIES, INC. (PIPE
SUPPORT ACCESSORIES MODEL 1.5 SPACER) AS NEED TO
HAVE SLOPE IN PIPE. SEE MECH DRAWINGS
EXISTING METAL DECK
V
.I .F
.) 5
0.050 ALUMINUM DRIP
EDGE
1 1/4" x 1 1/4" x 2" MODIFIED
BITUMEN CANT MODEL
DERBICANT
NEW RIGID
INSULATION PER
NEW ROOF PLAN
1/4" SOPRABOARD
EXISTING 2x BLOCKING TO REMAIN. IF BLCOKING IS
DAMAGED REPLACE WITH NEW. EXISTING 3/8" ANCHOR
TO REMAIN. ADD 1/4" x 4" S.S. COUNTERSUNK TAPCONS
INTO CONCRETE BEAM STAGGERED @ 6" O.C.
(CONTRACTOR TO VERIFY EXISTING CONDITIONS
ONCE EXISTING ROOF IS REMOVED. NOTIFY
ARCHITECT IF EXISTING CONDITIONS VARY)
#10 x 2 1/4" S.S. WOOD SCREWS
EXISTING LIGHTWEIGHT
CONCRETE AND METAL DECK
TO REMAIN
1/4" SOPRABOARD TO REMAIN
4"
EXISTING WALL
EXISTING METAL
DECK TO REMAIN
S5.1
1/4"
/2
HORIZ. GALV. STEEL PIPE
WELDED TO VERTICAL PIPE -
ALL ABOUT TYP.
ROOF MOUNTED
GUARDRAIL - SCH. 40 - 2"
⌀ GALV.
HORIZ. GALV. STEEL PIPE
WELDED TO VERTICAL PIPE -
ALL ABOUT TYP.
VERTICAL PIPE TO BE 48"
O.C. MAX. TYP. TO BE
PAINTED WHITE
7" x 7" x 1/4" GALV. STEEL PLATE FULLY
WELDED TO 2" DIA. GALV. PIPE, ALL ABOUT.
7" x 7" x 1/4" PLATE W/ (4) 1/2" THRU BOLT
ANCHORS W/ 1 1/2" WASHERS ON THE
UNDERSIDE OF THE JOISTS
BASE FLASHING
CAP FLASHING
4" MIN. FLANGE
STAINLESS STEEL
WORM GEAR CLAMP
NEW 7" x 7" x 1/4" GALV. STEEL PLATE
FULLY WELDED TO 2" DIA. GALV. PIPE,
ALL ABOUT. 7" x 7" x 1/4" PLATE W/ (4) 1/2"
THRU BOLT ANCHORS W/ 1 1/2"
WASHERS ON THE UNDERSIDE OF THE
JOISTS
/4
E Q
E
Q
M
IN
0.050 ALUMINUM DRIP
EDGE
1 1/4" x 1 1/4" x 2" MODIFIED
BITUMEN CANT MODEL
DERBICANT
NEW TAPERED
INSULATION PER
NEW ROOF PLAN
1/4" SOPRABOARD
#10 x 2 1/4" S.S. WOOD SCREWS
NEW TAPERED INSULATION
PER PLAN
1/4" SOPRABOARD
5"
EXISTING WALL
EXISTING METAL
DECK TO REMAIN
EXISTING METAL DECK TO
REMAIN
NEW MODIFIED BITUMEN
ROOF MEMBRANE TO RUN
UP AND OVER WALL TO
ROOF ABOVE
REPAIR EXISTING STUCCO AS
REQUIRED FOR PROPER
INSTALLATION OF NEW ROOF
MEMBRANE
EXISTING 2x BLOCKING TO REMAIN. IF BLCOKING IS
DAMAGED REPLACE WITH NEW. EXISTING 3/8"
ANCHOR TO REMAIN. ADD 1/4" x 4" S.S.
COUNTERSUNK TAPCONS INTO CONCRETE BEAM
STAGGERED @ 6" O.C.
NEW P.T. 2x BLOCKING ATTACH EACH INDIVIDUAL BLOCKING W/ #10 x 2 1/4" S.S. WOOD SCREWS @ 6"
O.C. STAGGERED
.050 ALUMINUM GRAVEL STOP
NEW 1/4" SOPRABOARD
TWO PIECE WALL REGLET
FLASHING PER DETAIL 1/A5.2
CONTRACTOR TO CUT STUCCO AS
REQUIRED FOR NEW FLASHING TO
BE INSTALLED. REPAIR STUCCO
AND SHEATHING AS REQUIRED
1 1/4" x 1 1/4" x 2" MODIFIED
BITUMEN CANT MODEL
DERBICANT
NEW TAPERED INSULATION
EXISTING METAL DECK TO REMAIN
EXISTING METAL DECK TO REMAIN
NEW TAPERED INSULATION
EXISTING 2x BLOCKING TO REMAIN. IF
BLCOKING IS DAMAGED REPLACE WITH
NEW. EXISTING 3/8" ANCHOR TO
REMAIN. ADD #12 S.S. COUNTERSUNK
TEK SCREWS INTO METAL BELOW
STAGGERED @ 6" O.C.
NEW P.T. 2x BLOCKING ATTACH EACH INDIVIDUAL BLOCKING W/ #10 x 2 1/4"
S.S. WOOD SCREWS @ 6" O.C.
STAGGERED
0.050 ALUMINUM DRIP
EDGE
M
IN
.050 ALUMINUM
GRAVEL STOP
DRAWING TITLE:
SHEET NO.
WDA PROJ. NO:
OWNER PROJ. NO:
SCALE: REFER TO SHEET
ISSUE/REVISION OF DRAWINGS:
ARCHITECT: AA0002541
ENGINEER: EB 0006884
PHASE:
CHECKED:
DRAWN:
T H
IS
D
O C
U M
E N
T C
O N
T A
IN
S
C O
P Y
R
IG
H T
E D
M A
T E
R
IA
L A
N D
T R
A D
E S
E C
R E
T I N
F O
R M
A T
IO
N
B E
L O
N G
IN
G
E X
C L U
S
IV
E L Y
T O
W
IL
L
IA
M S
O N
D A
C A
R A
S S
O C
IA
T
E S
IN
C
A N
Y U
N A
U T
H O
R
IZ
E D
U S
E
D
IS
C L O
S U
R E
D
IS
S
E M
IN
A
T
IO
N O
R D
U P
L
IC
A T
IO
N
O F
A N
Y O
F T
H E
I N
F O
R M
A T
IO
N
C O
N T
A
IN
E D
H E
R E
IN
M
A Y
R E
S U
L T
I N
L
IA
B
IL
IT
Y
U N
D E
R A
P P
L
IC
A B
L E
L A
W S
P R
O F
E S
S
IO
N A
L
T H
E O
D O
R E
J W
IL
L
IA
M S
O N
A R
P
E
/4
/2
:4 :5
A
M
ROOF DETAILS
th
S t.
N S t.
P e te rs b u rg
F
L
A5.4
2412-02
PERMIT SET
N O
R T
H E
A S
T H
IG
H
S C
H O
O L R
O O
F R
E P
L A
C E
M E
N T
B
U
IL
D
IN
G S
Checker
Author
NO. DATE DESCRIPTION
04/16/25 PH4 100% CD PERMIT
1 06/03/25 ADDENDUM #4
1 1/2" = 1'-0"A5.4
1 TYPICAL PIPE SUPPORT
1 1/2" = 1'-0"A5.4
2 ROOF EDGE DETAIL 2 - BUILDING 6
1 1/2" = 1'-0"A5.4
3 TYPICAL GUARDRAIL DETAIL
1 1/2" = 1'-0"A5.4
4 ROOF EDGE DETAIL - BUILDING 19
1 1/2" = 1'-0"A5.4
5 REGLET FLASHING DETAIL - BUILDING 19
| Sheets |
| A5.4 - ROOF DETAILS |
File details come from the government source that posted it. Updated .