2412-02_PCSB_Northeast_HS_Roof_Permit_Set_Arch_2025.04.16_S&S.pdf
PDF 22 MB Posted
- Attached to
- Reroof Buildings 3, 6, 19 and 28
- Solicitation number
- 25-CR-054
- Issued by
- Pinellas County, Florida
About this file
This is a comprehensive architectural permit set prepared by Williamson Dacar Associates for Pinellas County Schools, documenting a roof replacement project at Northeast High School involving Buildings 3, 6, 19, and 28, located at 5500 16th St. N in St. Petersburg, Florida. The project involves a complete roof system replacement, including removal of existing modified bitumen roofing, lightweight concrete, and insulation layers, followed by installation of new modified bitumen roofing systems, tapered insulation, recovery board, new roof drains, gutters, downspouts, scuppers, mechanical curbs, and associated flashing and edge details. The permit set is dated April 16, 2025, and includes detailed architectural, structural, mechanical, plumbing, and electrical plans across multiple buildings with varying roof configurations and areas.
The project appears to be funded through Pinellas County Schools, with a total project number of 9505 and an architectural project number of 2412-02. The roof replacement encompasses approximately 54,000 square feet across the four buildings, with each building having unique roof characteristics including flat and slightly sloped structures. The scope includes extensive demolition work, careful removal of existing roofing systems, repair of existing lightweight concrete decks, installation of new insulation with minimum R-25 values, modified bitumen roofing systems, and comprehensive waterproofing and flashing details. The project specifications emphasize compliance with the Florida Building Code, wind load requirements, and Pinellas County Schools' standard roofing details, with a focus on maintaining building functionality and minimizing disruption to school operations during the renovation.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
1 2 3 4 5
B
C
D
1 2 3 4 5
T H
IS
D
O C
U M
E N
T C
O N
T A
IN
S
C O
P Y
R
IG
H T
E D
M A
T E
R
IA
L A
N D
T R
A D
E S
E C
R E
T I N
F O
R M
A T
IO
N
B E
L O
N G
IN
G
E X
C L U
S
IV
E L Y
T O
W
IL
L
IA
M S
O N
D A
C A
R A
S S
O C
IA
T
E S
IN
C
A N
Y U
N A
U T
H O
R
IZ
E D
U S
E
D
IS
C L O
S U
R E
D
IS
S
E M
IN
A
T
IO
N O
R D
U P
L
IC
A T
IO
N
O F
A N
Y O
F T
H E
I N
F O
R M
A T
IO
N
C O
N T
A
IN
E D
H E
R E
IN
M
A Y
R E
S U
L T
I N
L
IA
B
IL
IT
Y
U N
D E
R
P
P L
IC
A B
L E
L A
W S
WDA Project No:
ARCHITECT :
2605 Enterprise Rd. E, Suite 200, Clearwater, Florida 33759
(727) 725-0951 www.wdastudio.com
NOTE:
TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND PROJECT
MANUALS ARE COMPLETE AND COMPLY WITH THE FLORIDA
BUILDING CODE 8TH EDITION AND FLORIDA FIRE PREVENTION CODE
8TH EDITION
ARCHITECT OF RECORD: DATE
ARCHITECT: Williamson Design Associates
ENGINEERING MATRIX, INC.
2860 SCHERER DR, STE 640, ST. PETERSBURG, FL 33716
PHONE (727) 573-4656
MECH, PLUM, ELEC.:
PINELLAS COUNTY SCHOOLS
1111 BELCHER ROAD LARGO, FLORIDA 33773
KEVIN K. HENDRICK, SUPERINTENDENT
LAURA HINE - CHAIRPERSON, AT LARGE D1 | LISA N. CANE - AT LARGE D2 | DAWN M. PETERS - AT LARGE D3
EILEEN M. LONG - SINGLE MEMBER D4 | KATIE BLAXBERG - SINGLE MEMBER D5
STEPHANIE MEYER - SINGLE MEMBER D6 | CAPRICE EDMOND - VICE CHAIRPERSON, SINGLE MEMBER D7
PSCSB PROJECT NO: 9505
/1
/2
:2 :3
P
M
2412-02
04/16/2025
NORTHEAST HIGH SCHOOL ROOF REPLACEMENT -
BUILDINGS 3, 6, 19 & 28
5500 16th St. N St. Petersburg, FL 33703
PERMIT SET
N O
R T
H E
A S
T H
IG
H
S C
H O
O L R
O O
F R
E P
L A
C E
M E
N T
B
U
IL
D
IN
G S
P E
R M
IT
S
T
/1
/2
04/18/2025
HGT.
AS REQUIRED
DRINKING WATER FOUNTAIN
CENTERLINE
NUMBER OR POUND
ACOUSTICAL
ADJUSTABLE
AIR CONDITIONING
ABOVE FINISHED FLOOR
ALTERNATE
ALUMINUM
PERPENDICULAR OR STRUCTURAL TEE
CHANNEL
DIAMETER OR ROUND
ALUMINUM
AMERICAN SOCIETY TESTING MATERIALS
AMERICAN INSTITUTE OF ARCHITECTS
ANCHOR BOLT
ANODIZED
ARCHITECT(URAL)
AUTOMATIC
BACK SPLASH
BASEMENT
BEARING
BETWEEN
BITUMINOUS
BLOCKING
BUILDING
BUILT-UP
ALIGN WITH WINDOW MULLION
CARPET (ED)
CATCH BASIN
CERAMIC TILE
CHAMFER
CHAIN LINK
CAST IRON
CIRCUMFERENCE
CLEARANCE
CONCRETE
CONCRETE MASONRY UNIT
CONSTRUCTION
CONTRACTOR
CONTINUOUS OR CONTINUE
CONTROL JOINT
CLEAR TEMPERED PLATE GLASS
COUNTER
CAST IN PLACE
FURNISHED INSTALLED
CLEAN OUT
AMERICAN INSTITUTE OF STEEL CONSTRUCTION
AMERICAN NATIONAL STANDARDS INSTITUTE
EXISTING
EXPOSED
EXPANSION JOINT
EXHAUST
ELECTRIC WATER HEATER
EACH WAY
ELEVATION
ELECTRIC
ELECTRIC HAND DRYER
DOWN LEADER
DRAWING
DOWN SPOUT
DIMENSION
DIAMETER
CASE DRAIN
COLD WATER
ELECTRIC WATER COOLER
GYPSUM WALL BOARD
GENERAL
GRADE (GRADING)
GALVANIZED IRON
GALVANIZED
FLUORESCENT
FLOOR (ING)
FLASHING
FINISH (ED)
FACE OF STUDS
FACE OF FINISH
FACE OF CONCRETE
FINISH FLOOR
FIRE EXTINGUISHER
FIRE ALARM
FACE OF STRUCTURAL MASONRY
FACE OF FINISHED MASONRY
FACE OF SHEATHING
EXTERIOR
HEATING/VENTILATING/
HEADER
HARDWARE
AIR CONDITIONING
A.R.
D.F.
EA.
ABV.
ACOUS.
ADJ.
A/C
A.F.F.
ALT.
AL.
ALUM.
A.S.T.M.
A.I.S.C.
A.I.A.
AB.
ANOD.
ARCH.
AUTO.
A.N.S.I.
BKSPL.
AWWM.
BRG.
BM.
BTWN.
BIT.
BLK.
BLKG.
BD.
BOT.
BRK.
BLDG.
BU.
BSMT.
CPT.
C.B.
CTR.
CLG.
CEM.
C.T.
CHAM.
CHN LNK
C.I.
C.I.P.
C.F.C.I.
CIR.
CIRCUM.
CLR
COL
CONC
CMU
CONST.
CONTR.
CONT.
CJ
CTPG
CTR
CO.
DN
DL
DWG
DS
DIM
DIA
DTL
DCD
CW
EXIST./EXTG.
EXP.
EJJT/ E.J.
EXH.
E.W.H.
E.W.
EQ.
ELEV
ELEC
E.W.C.
E.H.D.
FLUOR
FLR.
FLASH.
FIN.
FOF
FOC.
F.F./ FIN. FL
F.CLG/ FIN. CEIL.
FE.
FA
H OR HT.
GYP./GWB
GEN.
GD.
G.I.
GALV.
FT.
FTG.
FOS.
F.O.S.M.
F.O.SH.
FOFM
EXT.
HVAC.
HDR.
HDW.
E
BEAM
BRICK
BLOCK
BOARD
BOTTOM
CENTER
CEILING
CEMENT
CIRCLE
COLUMN
EACH
EAST
DOWN
EQUAL
DETAIL
FOOT
HEIGHT
FOOTING
ANGLE
AND
ABOVE
AT
FINISH CEILING
NATIONAL FIRE PROTECTION AGENCY
OCCUPATIONAL SAFETY AND
OWNER FURNISHED OWNER INSTALLED, (N.I.C.)
OWNER FURNISHED CONTRACTOR INSTALLED
SPANDRELITE PANEL GLASS
TINTED TEMPERED PLATE GLASS
REFLECTED
PLASTIC LAMINATE
TO MATCH EXISTING
REFERENCE OR SEE
INSIDE DIAMETER
INCLUDING
LEADED GLASS
LAMINATED GLASS
LAVATORY
LAMINATE (D)
JUNCTION
JANITORS CLOSET
JUNCTION BOX (ES)
INTERIOR
LIVE LOAD
INSULATE (D) (ING) (TION)
MANUFACTURE (ER)
MARBLE
MASONRY
MASONRY OPENING
MAXIMUM
MOISTURE RESISTANT
MOUNTED
MECHANIC (AL)
MIRROR GLASS
MISCELLANEOUS
NOT TO SCALE
ON CENTER (S)
OPENING
OVER ALL
MATERIAL
NATL. ELECTRIC CODE
NATL. SANITATION FOUND.
HEALTH ADMINISTRATION
PROPERTY LINE
PLYWOOD
ONE WAY GLASS
OPPOSITE HAND
PRESSURE TREATED
REFERENCE
REINFORCING
REQUIRED
ROUGH OPENING
RIGHT OF WAY
SCHEDULE
PAPER TOWEL DISPENSER
POUNDS PER CUBIC FOOT
POUNDS PER LINEAL FOOT
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
REVISION (S) (REVISED)
OUTSIDE DIAMETER
LIGHT WEIGHT
SOLID CORE
SPECIFICATION (S)
STAINLESS STEEL
SANITARY SEWER
STANDARD
STORAGE
STRUCTURAL
TOP AND BOTTOM
TOP OF FOUNDATION
TELEPHONE
TOP OF MASONRY
TOP OF CONCRETE
TO MATCH
TOP OF WALL
TOP OF ROOF DECK
SUSPENDED
TOTAL DYNAMIC HEAD
TOP OP ROOF PERIMETER
TONGUE AND GROOVE
TYPICAL
VAPOR BARRIER
VERTICAL
VENT THRU ROOF
WIDTH OR WEST
WATER CLOSET
VENEER PLASTER
WITHOUT
WATER PROOFING
WELDED WIRE FABRIC
WIRE GLASS
WATER HEATER
UNLESS OTHERWISE NOTED
VINYL COMPOSITION TILE
TELEVISION
HOSE BIB
HORIZONTAL (LY)
HOLLOW METAL
PLAM
LT.WT.
MANUF.
MARB.
MECH.
NFPA.
OSHA
O.F.O.I.
O.F.C.I.
PLYWD
REINF.
REQ'D.
SPEC.
STOR
STRUCT
T & B
T. OF F.
T.O.R.D.
T.O.R.F.
SUSP.
T & G.
VERT.
WNDW
W. HTR.
REFL
T.M.E.
RE:
LG.
LL.
LDG.
M.O.
MAS.
MAX.
MIN.
M/R
MTL.
MTD.
MG.
NTS
NEC
N.
MISC.
OA.
OC.
OPG.
NSF
MAT.
PNT
O.H.
OWG.
PL
P/LF
P/SF
P/CF
PTD.
PT.
P.T.
REF.
RAD.
RO
R/W
SCH.
SHT.
REV.
PSI
OD.
SC
S.
S.S.
S/S
STD
STL.
SPG
T.M.
TOH.
T.O.M.
T.O.C.
TEL.
TTPG
T.O.W.
TYP.
V.B.
U.O.N.
VTR.
VP
W.
WC.
W/
VCT.
W/O
WT.
WG
WD
WWF.
WP.
TV.
INSUL.
HORZ.
ID.
INCL.
JC
JB
INT.
L.
JT.
JCT.
LAV.
LAM.
HR.
HB.
HM.
MINIMUM
METAL
NORTH
PAINT
POINT
RADIUS
SHEET
SOUTH
STEEL
WITH
WINDOW
WOOD
WEIGHT
LENGTH
JOINT
HOUR
HEIGHT
FLOORFL.
DEMOLITIONDEMO
MASONRY CONTROL JOINTMCJ
RESTROOMR.R.
TEMPORARYTEMP.
INFORMATIONINFOR.
TRANSITIONTRANS.
B.O. BOTTOM OF
HANDICAPPED ACCESSIBLEH.C.
FLORIDA BUILDING CODE (S)FBC
F.V. FIELD VERIFY
ABBREVIATIONS
EPS EXPANDED POLYSTYRENE
W1
P-1
X
XXX
XX
XXX
XX
XXX
XX
XXX
100A
A0.13 1
BUILDING SECTION MARK
WALL SECTION MARK
GRADE / EARTH
CONCRETE
EXISTING WALL
SEE PARTITION TYPE/ WALL TYPE
REVISION MARK
DETAIL MARK
INTERIOR ELEVATION MARK
WINDOW NUMBER
PARTITION TYPE
DOOR NUMBER
ROOM NUMBER
EXTERIOR ELEVATION MARK
NEW WALL
SEE PARTITION TYPE/ WALL TYPE
STUCCO, PLASTER OR G.W.B.
SYMBOL AND MATERIAL LEGEND
NOTE:
SPECIFIC DETAILS MAY CONTAIN SYMBOLS FOR MATERIALS
THAT DIFFER FROM THESE GENERAL ITEMS NOTED.
DEMOLITION KEYED NOTE
NEW WORK KEYED NOTE
CEILING - 2X2 LAY-IN TILE
CEILING - 2X4 LAY IN TILE
BATT INSULATION
30'-03"
TOP OF BEAM
ELEVATION MARK
NORTH SYMBOL
1. VERIFY ALL CONDITIONS & DIMENSIONS & REPORT ANY DISCREPANCIES TO
THE ARCHITECT PRIOR TO BEGINNING WORK. VERIFY & BE RESPONSIBLE
FOR ALL DIMENSIONS & CONDITIONS ON THE JOB. THE ARCHITECT MUST BE
NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS & CONDITIONS
SHOWN BY THESE DRAWINGS AT THE TIME OF DISCOVERY.
2. THE PLANS SHOW THE LOCATION OF ALL FIXTURES & EQUIPMENT & ARE
INTENDED TO CONVEY THE GENERAL INTENT OF THE WORK IN SCOPE &
LAYOUT. THEY ARE NOT INTENDED TO SHOW IN MINUTE DETAIL EVERY &
ALL ACCESSORIES INTENDED FOR THE PURPOSE OF EXECUTION OF THE
WORK, BUT IS UNDERSTOOD THAT SUCH DETAILS ARE PART OF THIS
WORK.
3. NO WORK IS TO BE INSTALLED PRIOR TO THE SUBMISSION AND APPROVAL
OF APPROPRIATE AND REQUIRED SHOP DRAWINGS, SAMPLES, ETC. AS
DESCRIBED IN THE CONTRACT DOCUMENTS.
4. PROVIDE A COMPLETE & FINISHED PRODUCT. ANY ITEMS NOT SPECIFIED,
OR IDENTIFIED, BUT REQUIRED TO COMPLETE AN ASSEMBLY, SYSTEM, ETC.
SHALL BE CONSIDERED PART OF THIS CONTRACT.
5. COORDINATE AND ASSURE THAT ALL ITEMS OF WORK WILL FIT AND
FUNCTION IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS AND
THAT INDIVIDUAL PIECES OF THE SAME AND DIFFERENT SYSTEMS WILL
PROPERLY FUNCTION IN CONFORMANCE WITH THE CONTRACT
DOCUMENTS, THE MANUFACTURER AND INDUSTRY STANDARDS.
6. BE RESPONSIBLE FOR ALL DAMAGE, INSIDE OR OUTSIDE THE LIMIT OF
WORK DUE TO OPERATIONS. RESTORE ALL DAMAGED AREAS OR ITEMS TO
THEIR ORIGINAL CONDITION AT NO ADDITIONAL COST TO THE OWNER.
PROVIDE ALL TEMPORARY PROTECTION AS REQUIRED TO PROPERLY
SECURE THE SITE AND THE BUILDING FROM INTRUDERS, ANIMALS, AND THE
ELEMENTS.
7. BE RESPONSIBLE FOR ANY EXISTING MATERIAL OR SYSTEM INTEGRATED
WITH SCOPE OF WORK FOR CONFORMANCE WITH THE CONTRACT
DOCUMENTS AND OBJECTIVES OF THIS PROJECT. ALL CLEARANCES AND
CONFLICTS OF ANY AND ALL CONSTRUCTION; FRAMING/ MECHANICAL/
PLUMBING/ ELECTRICAL/ ETC REQUIRED SHALL BE ADJUSTED FOR PROPER
FIT, ACCESSIBILITY AND FUNCTION.
8. BE RESPONSIBLE FOR THE COORDINATION OF ALL TRADES AND WORK
DESCRIBED IN THE DRAWINGS. INDIVIDUAL CONTRACTORS SHALL BE
RESPONSIBLE FOR THE CONFORMANCE OF THEIR DESIGN AND EXECUTION
TO ALL APPLICABLE LOCAL, STATE AND FEDERAL BUILDING CODES AND
ORDINANCES, ZONING BYLAWS AND GOVERNING AGENCIES AS WELL AS
OSHA, NFPA AND THE HEALTH ACTS.
9. PURSUE THIS WORK IN A CLEAN, ORGANIZED, AND PROFESSIONAL MANNER
AND BE RESPONSIBLE FOR MAINTAINING THE SAFETY AND SECURITY OF
THE SITE DURING CONSTRUCTION.
10. IN THE EVENT OF A CONFLICT WITH ITEMS OR SYSTEMS SPECIFIED OR
DETAILED IN MORE THAN ONE LOCATION, PROVIDE THE MORE EXPENSIVE
OR HIGHER QUALITY ITEM.
11. SUPPLY ALL ITEMS IDENTIFIED TO BE PROVIDED IN THE SPECIFICATIONS OR
THE DRAWINGS INDEPENDENT OF BEING INDICATED WITHIN THE OTHER.
12. COORDINATE ALL DIMENSIONS OR EQUIPMENT & BUILT IN ITEMS WITH FINAL
PLACEMENT LOCATIONS AS-BUILT CONDITIONS.
13. IN ADDITION TO THE REQUIREMENTS OF THE SPECIFICATIONS ALL
MATERIAL SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE
MANUFACTURERS SPECIFICATIONS AND RELATED TRADE PRACTICES OR
STANDARDS. THE PREPARATIONS AND MODIFICATIONS OF UNDERLYING
CONDITIONS SHALL BE COMPLETE AND READY FOR THE NEXT TRADE OR
PRODUCT. ALL WORK SHALL BE IN CONFORMANCE WITH GOOD TRADE
PRACTICE AND PERFORMED BY SKILLED WORKERS, TRAINED IN THE
INSTALLATION OF THE PRODUCT BEING INSTALLED. WORK NOT
CONFORMING TO THESE REQUIREMENTS SHALL BE CAUSE FOR
REJECTION. SATISFACTORY REMEDIES MAY INVOLVE COMPLETE REMOVAL
AND REPLACEMENT OF DEFECTIVE WORK OR MATERIAL AT THE
CONTRACTORS EXPENSE.
14. BE RESPONSIBLE FOR ALL REQUIRED AS BUILT WORK DRAWINGS,
CALCULATIONS AND DIAGRAMS FOR ALL SYSTEMS AS IDENTIFIED IN THE
DRAWING SPECS AT THE TIME OF INSTALLATION. COORDINATION
DRAWINGS ARE REQUIRED PER SPECIFICATIONS TO IDENTIFY PROPER FIT
AND FUNCTIONS AS WELL AS IDENTIFY ANY POSSIBLE CONFLICTS PRIOR TO
COMMENCING WITH SPECIFIC WORK.
15. ANY CONTRACTOR, SUBCONTRACTOR, INDIVIDUAL, COMPANY, OR THEIR
DESIGNEES PERFORMING WORK OR SERVICES FOR THIS PROJECT, BE IT
FOR MATERIALS, LABOR OR BOTH SHALL BE RESPONSIBLE FOR THE
DETAILED EXAMINATION OF EXISTING CONDITIONS AT THE SITE, AS
INDICATED IN DRAWINGS, OR IN OTHER INFORMATION AVAILABLE FROM A
PUBLIC AGENCY OR UTILITY COMPANY. NO CONSIDERATION SHALL BE
GIVEN FOR CLAIMS MADE AS A RESULT OF FAILURE TO UNDERSTAND,
IDENTIFY OR ESTABLISH EXISTING CONDITIONS. ANY DAMAGE TO EXISTING
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND REPAIRED AT
HIS OWN EXPENSE.
16. SPECIFICATIONS & REQUIREMENTS INDICATED ON THE DRAWINGS ARE
CONSIDERED MINIMUM ACCEPTABLE CRITERIA & MAY BE SUPERSEDED BY
MORE STRINGENT CRITERIA REQUIRED AS PART OF THE DOCUMENTS.
NOTIFY THE ARCHITECT FOR ANY POSSIBLE CONFLICTS OR
DISCREPANCIES PRIOR TO COMMENCING THE SPECIFIC WORK..
17. ALL WOOD IN CONTACT WITH THE CONCRETE, MASONRY OR AS INDICATED
OR REQUIRED SHALL BE PRESSURE PRESERVATIVE TREATED.
18. COORDINATE & VERIFY ALL EXTERIOR WALL CONTROL & EXPANSION
JOINTS PRIOR TO THE COMMENCEMENT OF SPECIFIC WORK.
19. ALL CONDUIT, PIPING & DUCTWORK PENETRATING ANY RATED ASSEMBLY
CEILING OR WALLS SHALL HAVE AN APPROVED FIRE RATED ASSEMBLY FOR
THE SPECIFIC APPLICATION, AS SHOWN HEREIN AND / OR IN THE
SPECIFICATIONS.
20. ALL FINISHES SHALL BE PROTECTED WHERE INDICATED AS THE FINAL
FINISH OR FINISH TO REMAIN. BE RESPONSIBLE FOR ALL REPAIRS TO
PRODUCE A UNIFORM FINISH AT FINAL COMPLETION.
21. ALL ROOF PENETRATIONS AND JOINTS SHALL BE PROPERLY FLASHED AND
CAULKED TIGHT WITH SPECIFIED SEALANT APPLICABLE TO THE
CONDITIONS, AND PROVIDE A WEATHER TIGHT ASSEMBLY
PROJECT NOTES
LOCATION MAPS
LOCATION
DRAWING TITLE:
SHEET NO.
WDA PROJ. NO:
OWNER PROJ. NO:
SCALE: REFER TO SHEET
ISSUE/REVISION OF DRAWINGS:
ARCHITECT: AA0002541
ENGINEER: EB 0006884
PHASE:
CHECKED:
DRAWN:
T H
IS
D
O C
U M
E N
T C
O N
T A
IN
S
C O
P Y
R
IG
H T
E D
M A
T E
R
IA
L A
N D
T R
A D
E S
E C
R E
T I N
F O
R M
A T
IO
N
B E
L O
N G
IN
G
E X
C L U
S
IV
E L Y
T O
W
IL
L
IA
M S
O N
D A
C A
R A
S S
O C
IA
T
E S
IN
C
A N
Y U
N A
U T
H O
R
IZ
E D
U S
E
D
IS
C L O
S U
R E
D
IS
S
E M
IN
A
T
IO
N O
R D
U P
L
IC
A T
IO
N
O F
A N
Y O
F T
H E
I N
F O
R M
A T
IO
N
C O
N T
A
IN
E D
H E
R E
IN
M
A Y
R E
S U
L T
I N
L
IA
B
IL
IT
Y
U N
D E
R A
P P
L
IC
A B
L
W S
/1
/2
:2 :3
P
M
INDEX, GENERAL
NOTES &
ABBREVIATIONS
th
S t.
N S t.
P e te rs b u rg
F
L
T-2
2412-02
PERMIT SET
N O
R T
H E
A S
T H
IG
H
S C
H O
O L R
O O
F R
E P
L A
C E
M E
N T
B
U
IL
D
IN
G S
WDA
WDA
B6
DRAWING INDEX
SHEET
NUMBER SHEET NAME
VOLUME
SET
0 - GENERAL SHEETS
T-1 COVER
T-2 INDEX, GENERAL NOTES & ABBREVIATIONS
A1 - DEMOLITION ROOF PLANS
A0.1 OVERALL DEMOLITION ROOF PLAN
A0.2 DEMOLITION ROOF PLAN - BUILDING 3
A0.3 DEMOLITION ROOF PLAN - BUILDING 6
A0.3.1 DEMOLITION ROOF PLAN NOTES - BUILDING 6
A0.4 DEMOLITION ROOF PLAN - BUILDING 19
A0.5 DEMOLITION ROOF PLAN - BUILDING 28
A1 - ROOF PLANS
A1.0 OVERALL NEW ROOF PLAN
A1.1 NEW ROOF PLAN - BUILDING 3
A1.2 NEW ROOF PLAN - BUILDING 6
A1.3 NEW ROOF PLAN - BUILDING 19
A1.4 NEW ROOF PLAN - BUILDING 28
A1 - ROOF PLANS
A1.5 TAPERED INSULATION LAYOUT PLAN - BUILDING 6
A1.6 TAPERED INSULATION LAYOUT PLAN - BUILDING 19
A1.7 TAPERED INSULATION LAYOUT PLAN - BUILDING 28
A5 - PARTITION TYPES AND DETAILS
A5.1 ROOF DETAILS
A5.2 ROOF DETAILS
A5.3 ROOF DETAILS
A5.4 ROOF DETAILS
A5.5 ROOF DETAILS (PCS STANDARDS) 1
A5.6 ROOF DETAILS (PCS STANDARDS)
S - STRUCTURAL
S1.0 WIND LOAD PLAN - BUILDING 3
S1.1 WIND LOAD PLAN - BUILDING 6
S1.2 WIND LOAD PLAN - BUILDING 19
S1.3 WIND LOAD PLAN - BUILDING 28
S1.4 PARTIAL ROOF FRAMING PLAN - BUILDING 19
S5.1 STRUCTURAL DETAILS
M - MECHANICAL
M0.0 MECHANICAL SYMBOLS LEGEND
M1.0.3 DEMOLITION MECHANICAL ROOF PLAN BLDG 3
M1.0.6 DEMOLITION MECHANICAL ROOF PLAN BLDG 6
M1.0.19 DEMOLITION MECHANICAL ROOF PLAN BLDG 19
M1.0.28 DEMOLITION MECHANICAL ROOF PLAN BLDG 28
M1.1.3 MECHANICAL ROOF PLAN BLDG 3
M1.1.6 MECHANICAL ROOF PLAN BLDG 6
M1.1.19 MECHANICAL ROOF PLAN BLDG 19
M1.1.28 MECHANICAL ROOF PLAN BLDG 28
M3.1 MECHANICAL DETAILS
M4.1 MECHANICAL SCHEDULES
P - PLUMBING
P0.0 PLUMBING NOTES LEGEND AND FIXTURE SCHEDULE
P1.0.3 DEMOLITION PLUMBING ROOF PLAN BLDG 3
P1.0.6 DEMOLITION PLUMBING ROOF PLAN BLDG 6
P1.0.19 DEMOLITION PLUMBING ROOF PLAN BLDG 19
P1.0.28 DEMOLITION PLUMBING ROOF PLAN BLDG 28
P1.1.3 PLUMBING ROOF PLAN BLDG 3
P1.1.6 PLUMBING ROOF PLAN BLDG 6
P1.1.19 PLUMBING ROOF PLAN BLDG 19
P1.1.28 PLUMBING ROOF PLAN BLDG 28
E - ELECTRICAL
E0.0 ELECTRICAL GENERAL LEGEND & HVAC SCHEDULE
E1.1.3 POWER ROOF PLAN BLDG 3
E1.1.6 POWER ROOF PLAN BLDG 6
E1.1.19 POWER ROOF PLAN BLDG 19
E1.1.28 POWER ROOF PLAN BLDG 28
E5.1 ELECTRICAL DETAILS
E5.2 ELECTRICAL DETAILS
B3
B28
B19
NO. DATE DESCRIPTION
1 01/07/25 PH1 SD
2 03/04/25 PH2 DD
3 04/01/25 PH3 100% CD
4 04/16/25 PH4 100% CD PERMIT
B22
T H
S T
R E
E T
N O
R T
H
B24 B6
B26 B28
B23
B5 B3 B1
B17
B18
B19 B20
B25 B2
B1
NORTH
B1
SOUTH
54TH AVENUE NORTH
B21
P1P2
P3 P4 P5
NO SCALE
KEY PLAN
EXISTING ONE STORY
BUILDING 19
SHEET A0.4
EXISTING ONE STORY
BUILDING 6
SHEET A0.3
EXISTING ONE STORY
BUILDING 3
SHEET A0.2
EXISTING TWO STORY
BUILDING 28
SHEET A0.5
146' - 2 1/2"
196' - 1"
/2
88' - 8"
/2
130' - 3 1/2"
1. THESE ROOFING PLANS CONTAIN APPROXIMATE DEPICTIONS OF EXISTING CONDITIONS. EVERY
ROOFTOP VENT, PIPE, CONDUIT, SUPPORT, PIECE OF EQUIPMENT, AND OTHER TYPE OF ROOF
PENETRATION MAY NOT BE INDICATED. THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING THE EXISTING CONDITIONS AND ACCOUNTING FOR THEM IN THE BIDS. THE CONTRACTOR SHALL
COORDINATE WITH OWNER WHICH PIECES OF EQUIPMENT HAVE BEEN ABANDONED.
2. THE CONTRACTOR SHALL VISIT AND OBSERVE THE OVERALL PROJECT SITE AND ROOFING
SURFACE PRIOR TO SUBMITTING ANY BID. THE CONTRACTOR SHALL OBSERVE AND ACCOUNT FOR
THE CONDITION OF THE EXISTING ROOFING, FLASHING, GUTTER, DOWNLEADER, AND ROOFTOP
EQUIPMENT. THE CONTRACTOR SHALL ACCOUNT FOR LIMITATIONS OF ACCESS, ROOF REMOVAL
AND REPLACEMENT, STAGING AND OTHER OVERALL SITE FACTORS THAT MIGHT IMPACT THE
SCOPE OF WORK IN THE BID. COORDINATE WITH OWNER TO ENSURE THAT STAGING BARRIERS,
TEMPORARY UTILITIES, TRAFFIC CONTROL, AND PROTECTION OF OCCUPANTS IS ADHERED TO.
3. THE CONTRACTOR SHALL TYP REMOVE ALL ABANDONED EQUIPMENT AND THE ELECTRICAL
DISTRIBUTION TO IT (UNLESS DIRECTED OTHERWISE BY OWNER) AND REPAIR ALL DECK
OPENINGS PRIOR TO REROOFING. DECK REPAIR SHALL TYP BE DONE WITH THE STRUCTURAL
ROOF DECK MATERIAL USED FOR THE ORIGINAL ROOF DECK. WHERE STEEL DECKING IS USED,
THE NEW DECKING SHALL SPAN AS NOTED IN THE STRUCTURAL DRAWINGS. OTHER ROOF
DECKING MATERIALS SHALL BE REPAIRED PER THE MANUFACTURER'S STANDARD DETAILS AND
REQUIREMENTS AND RECOMMENDATIONS.
4. REMOVAL OF THE EXISTING ROOF DOWN TO THE EXISTING LIGHTWEIGHT CONCRETE OR
METAL DECK EXPOSED TO THE WEATHER AFTER DEMOLITION. ALL DAMAGE FROM WATER
INFILTRATION RELATED TO THE ROOF WORK SHALL THE RESPONSIBILITY OF THE CONTRACTOR
TO REPAIR AT NO COST TO THE OWNER OR ARCHITECT OR ENGINEER.
5. REMOVE EXISTING ROOFING SYSTEM, INCLUDING (WHERE PRESENT) BUT NOT LIMITED TO:
MODIFIED BITUMEN, FLASHING, EXPANSION JOINT COVERS, EDGE FLASHING AND ALL RELATED
ACCESSORIES. DO NOT DROP MATERIALS FROM ROOF TO GROUND. SWEEP EXPOSED ROOF
DECK CLEAN AND PREP FOR NEW ROOF SYSTEM, TO INCLUDE: MODIFIED BITUMEN ROOF SYSTEM, AND ALL RELATED FLASHING. PRIOR TO INSTALLATION OF ANY NEW ROOFING MATERIALS, ROOF
MUST BE CLEAN AND FREE OF ALL DEBRIS.
6. ALL ROOF-TOP EQUIPMENT SHALL REMAIN IN NORMAL OPERATION DURING THE PERIOD OF
REMOVAL AND REROOFING, EXCEPT AS REQUIRED FOR CURB REPLACEMENT OR WHEN INTAKES
MUST BE BLOCKED TO PREVENT FUMES AND DEBRIS FROM ENTERING EQUIPMENT OR AIR
INTAKES. COORDINATE ALL EQUIPMENT REMOVAL AND SHUT-DOWN WITH OWNER MAINTENANCE
AND STAFF TO MINIMIZE DISRUPTION TO THE OPERATION OF THE SCHOOL. REPLACE OR
REINSTALL ALL REMOVED EQUIPMENT AS REQUIRED IN THESE DRAWINGS IN A TIMELY MANNER
TO PREVENT DISRUPTION OF THE OPERATION OF THE SCHOOL. ALL REQUIRED EQUIPMENT SHUT
DOWN MUST BE COORDINATED 2-WEEKS IN ADVANCE OF THE REQUIRED SHUT DOWN.
7. NO WELDING IS TO TAKE PLACE OVER OCCUPIED SPACE BELOW. WHERE WELDING IS REQUIRED, PROVIDE PROTECTION FROM SPARKS FOR ALL SURROUNDING MATERIALS.
8. ALL DISCONNECTION AND REINSTALLATION OF ROOFTOP ELECTRICAL AND MECHANICAL
SYSTEMS ARE TO BE PERFORMED BY LICENSED, QUALIFIED ELECTRICAL AND MECHANICAL
CONTRACTORS. ALL REMOVED EQUIPMENT THAT IS TO BE REINSTALLED ON ROOF IS TO BE
STORED IN A CLEAN, DRY, SECURE LOCATION UNTIL REINSTALLATION.
9. THE CONTRACTOR SHALL SELECT AND INSTALL A ROOF SYSTEM AS DESCRIBED IN THESE
DRAWINGS AND SPECIFICATIONS, AND AS REQUIRED BY OWNER ANY ROOF SYSTEM SUPPLIED
THAT SUBSTANTIALLY DIFFERS FROM THE REQUIRED SYSTEM SHALL REQUIRE REDESIGN AND
REENGINEERING, REVISIONS TO DETAILS, REVIEWS, OWNER APPROVAL, AND
MEETINGS/COORDINATION BETWEEN DESIGNERS AND ENGINEERS, ALL AT THE CONTRACTOR'S
EXPENSE.
10. THE ROOF SYSTEM SELECTED BY THE CONTRACTOR SHALL COMPLY WITH THE FLORIDA
BUILDING CODE AND CONFORM TO THE OWNER REQUIREMENTS NOTED IN THE PROJECT
MANUAL.
11. THE CONTRACTOR SHALL INSPECT THE EXISTING LIGHTWEIGHT CONCRETE AND INSULATION
SURFACE AFTER ROOFING SYSTEM IS REMOVAL AND IDENTIFY ALL AREAS OF APPARENT
DAMAGE, DETERIORATION, OR OTHER COMPROMISE TO THE DECK'S STRUCTURAL INTEGRITY AND
STABILITY FOR THE APPLICATION OF THE SELECTED INSULATION/REROOFING SYSTEM. SUCH
DAMAGE MAY BE PRE-EXISTING OR CAUSED BY THE REMOVAL OF THE EXISTING ROOFING
SYSTEM, ROOFTOP EQUIPMENT, OR ACCESSORIES. THE CONTRACTOR SHALL NOTIFY THE
ARCHITECT AND ENGINEER OF ANY DAMAGE, DETERIORATED, OR UNSUITABLE LIGHTWEIGHT
CONCRETE.
12. UPON REMOVAL OF ROOFING SYSTEM, CONTRACTOR MUST NOTIFY ARCHITECT IF THERE ARE ANY EXISTING SIGNIFICANT CRACKS IN THE EXISTING LIGHTWEIGHT CONCRETE OR OTHER ROOF
SUBSTRATE.
13. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF ANY WORK INDICATED IN THE
CONTRACT DOCUMENTS CANNOT BE PERFORMED DUE TO EXISTING FIELD CONDITIONS. OWNER
RESERVES THE RIGHT TO KEEP ANY MATERIALS FOUND DURING DEMOLITION. SUCH MATERIALS
SHALL BE IDENTIFIED SUCH THAT CONTRACTOR CAN PLACE ASIDE FOR OWNER.
14. DURING DEMOLITION THE CONTRACTOR SHALL PROVIDE HAND HELD FIRE EXTINGUISHER OR WATER SUPPLY CAPABLE OF 10 GAL./MINUTE FLOW FOR INCIDENTAL FIRES. IN ADDITION, THE
CONTRACTOR IS TO HAVE A TELEPHONE AVAILABLE TO CALL FOR EMERGENCIES.
15. THE CONTRACTOR SHALL VERIFY THAT EGRESS IS MAINTAINED FOR ALL OCCUPIED AREAS OF
THE BUILDING SITE THROUGHOUT DEMOLITION & CONSTRUCTION.
16. DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH ALL CODES AND ORDINANCES
AS SET FORTH BY ALL GOVERNING AUTHORITIES.
17. THE CONTRACTOR SHALL CAP ALL MISC. ELECTRICAL, MECHANICAL, PLUMBING UTILITIES THAT
SERVICE THIS AREA AND ARE NOT REQUIRED FOR NEW CONSTRUCTION OR REQUIRED FOR
CONTINUED OPERATION OF EXISTING SYSTEMS OUT OF VIEW.
18. UPON FINAL REMOVAL OF ALL ROOFING MATERIALS, THE SURROUNDING AREAS SHALL BE
POLICED FOR MISCELLANEOUS DEBRIS TO BE REMOVED. LEAVE THE ROOF AREA IN A CLEAN
CONDITION.
19. ALL DEBRIS SHALL BE REMOVED FROM SITE DAILY TO AN APPROVED DUMPING FACILITY WHICH
MEETS FEDERAL AND LOCAL REQUIREMENTS, OR A CONTRACTOR SUPPLIED DUMPSTER
LOCATED PER OWNER. NO BURNING ON SITE WILL BE ALLOWED. OWNER'S DUMPSTER MAY NOT
BE USED.
20. THE CONTRACTOR SHALL REPAIR, CLEAN, OR REPLACE ANY DAMAGE TO THE EXISTING
ADJACENT FINISH MATERIALS, OTHER STRUCTURES, AND GROUND AREAS NOT BEING
DEMOLISHED.
21. AFTER DEMOLITION THE CONTRACTOR IS TO REPAIR AND PATCH ALL SURFACES EFFECTED BY
DEMOLITION, TO A LIKE NEW OR MATCHING ADJACENT CONDITION. MATCH BRICK, BLOCK,
STUCCO, ETC. AS MAYBE REQUIRED.
22. ALL EXISTING LIGHTWEIGHT CONCRETE THAT IS TO REMAIN AND IS DAMAGED FROM THE
REMOVAL OF THE EXISTING ROOF SYSTEM SHALL BE REPAIRED. ALL DIVOTS, CRACKS BIGGER
THEN A 1/4" SHOULD BE FILLED AND SMOOTHED OUT BEFORE NEW MATERIAL CAN BE ADDED. IF
WITH LIKE MATERIAL.
GENERAL DEMOLITION NOTES
DRAWING TITLE:
SHEET NO.
WDA PROJ. NO:
OWNER PROJ. NO:
SCALE: REFER TO SHEET
ISSUE/REVISION OF DRAWINGS:
ARCHITECT: AA0002541
ENGINEER: EB 0006884
PHASE:
CHECKED:
DRAWN:
T H
IS
D
O C
U M
E N
T C
O N
T A
IN
S
C O
P Y
R
IG
H T
E D
M A
T E
R
IA
L A
N D
T R
A D
E S
E C
R E
T I N
F O
R M
A T
IO
N
B E
L O
N G
IN
G
E X
C L U
S
IV
E L Y
T O
W
IL
L
IA
M S
O N
D A
C A
R A
S S
O C
IA
T
E S
IN
C
A N
Y U
N A
U T
H O
R
IZ
E D
U S
E
D
IS
C L O
S U
R E
D
IS
S
E M
IN
A
T
IO
N O
R D
U P
L
IC
A T
IO
N
O F
A N
Y O
F T
H E
I N
F O
R M
A T
IO
N
C O
N T
A
IN
E D
H E
R E
IN
M
A Y
R E
S U
L T
I N
L
IA
B
IL
IT
Y
U N
D E
R A
P P
L
IC
A B
W S
/1
/2
:2 :3
P
M
OVERALL
DEMOLITION
ROOF PLAN
th
S t.
N S t.
P e te rs b u rg
F
L
A0.1
2412-02
PERMIT SET
N O
R T
H E
A S
T H
IG
H
S C
H O
O L R
O O
F R
E P
L A
C E
M E
N T
B
U
IL
D
IN
G S
BL / TW
TAW
1" = 40'-0"A0.1
1 OVERALL DEMOLITION ROOF PLAN
NO. DATE DESCRIPTION
1 01/07/25 PH1 SD
2 03/04/25 PH2 DD
3 04/01/25 PH3 100% CD
AREA A
AREA B
12' - 11 1/2"
/2
19' - 0" 15' - 0 1/2" 44' - 3"
138' - 1"
53' - 0"
67' - 0"
/2
6' - 0 1/2"
8' - 2"
RD1 RD2
RD3 RD4
RD5 RD6
RD7RD8
RD9
RD10
RD11
RD12
RD13
RD14 RD15
RD16 RD17
RD18 RD19
3 333
3 3
MECHANICAL EQUIPMENT/ EXHAUST HOOD
INDICATES EXISTING WALL BELOW
ROOF LEGEND
DL DOWNLEADERS
PLUMBING VENTS
EXISTING ROOF DRAINS
THRU WALL OVERFLOW SCUPPER LOCATIONS
RD#
REMOVE PLUMBING VENT STACK FLASHING PLYS. CLEAN PPIPE IN PREPARATION FOR
NEW FLASHING. EXTEND PIPING TO MEET THE CODE REQUIREMENT HEIGHT OF 10"
MIN. ABOVE FINISH ROOF, IF NECESSARY.
REMOVE ALL ROOF FLASHING, BLOCKING, TRIM, EXISTING BUILT-UP ROOFING
SYSTEM, INSULATION, CRICKET, BALLAST AND MISCELLANEOUS PLYS, DOWN TO
EXISTING LIGHTWEIGHT CONCRETE DECK, CLEAN DECK FREE OF EMBEDS AND
ADHESIVES, PATCH AREAS FOR FOR SMOOTH UNIFORM SURFACE. CLEAN SURFACE
TO MANUFACTURER'S RECOMMENDATIONS (IF APPLICABLE).
REMOVE DRAIN STRAINER, RING AND RELATED HARDWARE. FULLY CLEAN INNER
SURFACE OF DRAIN BOWL TO REMOVE PITCH, MASTIC, GRAVEL, ASPHALT,
DEBRIS, ETC. AND CLEAN STRAINER RING SURFACE. INSPECT DRAIN BOWL FOR
CRACKS AND/OR DAMAGE. NOTIFY A/E IF DAMAGE IS FOUND. INSPECT DRAIN
BOWL TO PIPE CONNECTION TO ENSURE WATER TIGHT CONDITION. HAVE A
LICENSED PLUMBER, WHO IS FULLY TRAINED IN, AND HAS EXPERIENCE IN,
CLEARING/CLEANING ROOF DRAINS IN THIS SITUATION, AUGER/SNAKE CLEAN
DRAIN PIPE DOWN TO 30' PAST ROOF DRAIN. IF THE DRAIN CANNOT BE CLEANED
DOWN TO 30' THEN VERIFY INNER DRAIN PIPE CONDITION BY VIDEO CAMERA
EQUIPMENT. SUPPLY OWNER & A/E WITH VIDEO DOCUMENTATION IN DIGITAL
FORMAT. WATER TEST TO ENSURE UNRESTRICTED FLOW PRIOR TO INSTALLING
NEW DRAIN COMPONENTS. REPAINT EXPOSED SURFACES/AREAS IF NECESSARY/
NOTIFY OWNER & A/E IMMEDIATELY OF DAMAGE.
REMOVE EXISTING THRU WALL SCUPPER AND FLASHING. PREP OPENING FOR
INSTALLATION OF NEW SCUPPER FLASHING
EXISTING PARAPET CAP METAL, AND FLASHING, CLEATS AND RELATED
FLASHING TO BE REMOVED, TYP. ALL LOCATIONS. INSPECT EXISTING PARAPET
WALL FOR DAMAGE. NOTIFY A/E IF DAMAGE IS FOUND.
EXISTING TWO PIECE WALL REGLET SYSTEM TO BE REMOVED AND REPALCED. TYPICAL ALL
LOCATIONS.
EXISTING MECHANICAL EQUIPMENT TO BE REMOVED AND RE-INSTALLED. REMOVE
FLASHING, SHEATHING, MECHANICAL FASTENERS, SUPPORTS, AND CURB.
CONTRACTOR TO SUPPORT EXISTING MECHANICAL. EQUIPMENT UNTIL NEW CURB IS
INSTALLED. RECONNECT ELECTRICAL AND MECH UNIT ON NEW CURB.
PATCH ANY AND ALL EXISTING LIGHTWEIGHT CONCRETE ROOF SYSTEM AS NEEDED
DUE TO DEMOLITION OF EXISTING CONDITIONS. (TYP. ALL).
ROOF DEMOLITION NOTES:
REMOVE EXISTING SCUTTLE ASSEMBLY, CURB FLASHING AND PLYS, AND CAP
FASTENERS. EXISTING STEEL TO REMAIN. NOTIFY OWNER/ARCHITECT OF ANY
DAMAGE DISCOVERED DURING DEMOLITION. PREP FOR REINSTALL OF NEW ROOF
SCUTTLE ASSEMBLY. EXISTING ROOF LADDER TO BE REMOVED.
EXISTING ELECTRICAL CONDUIT TO REMAIN. EXISTING PITCH PAN TO BE REMOVED.
RELOCATED ELECTRICAL CONDUIT TO NEW STANDS.
EXISTING EDGE FLASHING, CLEATS, AND RELATED FLASHING TO BE REMOVED
TYPICAL ALL LOCATIONS. INSPECT EXISTING WALL BLOCKING FOR DAMAGE. NOTIFY
A/E IF DAMAGE IS FOUND.
CONTRACTOR TO VERIFY EXISTING ANTENNA, PIPE SUPPORT AND ATTACHMENTS ARE
IN USE. CONTRACTOR TO REMOVE ALL EXISTING IF NOT IN USE. IF IN USE
CONTRACTOR TO RERUN WIRES IN BUILDING TO NEW STAND FOR ANTENNAS.
EXISTING ELECTRICAL, PITCH PAN, SUPPORTS, ABANDONED CURBS AND ETC TO BE
REMOVED.
EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. REMOVE FLASHING, SHEATHING,
MECHANICAL FASTENERS, SUPPORTS, CURB, EXISTING ABANDONED ELECTRICAL, AND
PITCH PAN. NEW MECHANICAL EQUIPMENT TO BE INSTALLED (REFER TO MECH.
DRAWINGS). NEW CURB TO BE PROVIDED FOR MECHANICAL EQUIPMENT.
EXISTING WALL MOUNTED ROOF ACCESS LADDERS TO BE REMOVED AND REPLACED.
TYP. ALL LOCATIONS
EXISTING PITCH PAN WITH STEEL ANGLE SUPPORT TO BE REMOVED. PATCH
LIGHTWEIGHT CONCRETE AS REQUIRED FOR NEW ROOF SYSTEM
EXISTING MECHANICAL EQUIPMENT TO BE UN-INSTALLED. CONTRACTOR TO REMOVE
EXISTING EXTENSION CURB, EXISTING CURB. EXISTING CHILL WATER PIPING TO BE
DISCONNECTED TO ACCOMMODATE NEW STRUCTURAL CURB UNIT. EXISTING STEEL
SUPPORTS ADJUST SUPPORT AS REQUIRED.
CONTRACTOR TO REMOVE EXISTING CONDENSATE LINES ON MECHANICAL UNITS AND
REINSTALL WITH NEW PIPE SUPPORTS AFTER NEW CURBS IS INSTALLED AND THE
EXISTING UNITS IS ON THE NEW CURB.
EXISTING GUTTERS TO BE REMOVED AND DOWNLEADERS (D.L.) ALL TO BE
REMOVED AND REINSTALLED AFTER NEW GUTTER IS INSTALLED.
REMOVE EXISTING THRU WALL SCUPPER AND FLASHING. INFILL OPENING TO MATCH
EXISTING CONSTRUCTION.
EXISTING LIGHTNING HORN SYSTEM TO BE UNINSTALLED AND STORED OFF ROOF
UNTILL NEW ROOF SYSTEM IS INSTALLED. ALL EXISTING WIRING TO BE REMOVED
FROM ROOF AND RE-RUN INSIDE BUILDING. CONTRACTOR TO CONTACT HUNTER
ROSS W/ THOR GUARD REGIONAL MANAGER AT 1-(813)-784-4865 or by Email:
Hunterross@verizon.net TO DO ALL WORK TO THE SYSTEM AND PROVIDE A PRICE
FOR THE WORK.
REMOVE ALL ROOF FLASHING, BLOCKING, TRIM, EXISTING BUILT-UP ROOFING
SYSTEM, INSULATION, CRICKET, BALLAST AND MISCELLANEOUS PLYS, AND
LIGHTWEIGHT CONCRETE DOWN TO EXISTING METAL DECK, CLEAN METAL DECK
FREE OF EMBEDS, LIGHTWEIGHT CONCRETE. CLEAN SURFACE OF METAL DECK
AND FLUTES TO MANUFACTURER'S RECOMMENDATIONS.
CONTRACTOR TO REMOVE EXISTING ELEC., PIPE AND RELOCATE TO NEW ROOF
PENETRATION VAULT CURB. COORDINATE WITH OWNER ON LOCATION FOR NEW
VAULT PENETRATION CURB.
EXISTING MOISTURE SATURATED LIGHTWEIGHT CONCRETE IN HATCHED AREAS
ARE TO BE RMEOVED DOWN TO THE EXISTINGMETAL DECK. PREP AREA FOR
INSTALLATION OF NEW LIGHTWEIGHT CONCRETE.
EXISTING GOOSENECK ASSEMBLY TO BE REMOVED. PREP AREA FOR
INSTALLATION OF NEW GOOSENECK ASSMEBLY.
1. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF ANY WORK
INDICATED IN THE CONTRACT DOCUMENTS CANNOT BE PERFORMED DUE TO
EXISTING FIELD CONDITIONS. OWNER RESERVES THE RIGHT TO KEEP ANY
MATERIALS FOUND DURING DEMOLITION. SUCH MATERIALS SHALL BE IDENTIFIED
SUCH THAT CONTRACTOR CAN PLACE ASIDE FOR OWNER.
2. DURING DEMOLITION THE CONTRACTOR SHALL PROVIDE HAND HELD FIRE
EXTINGUISHER OR WATER SUPPLY CAPABLE OF 10 GAL./MINUTE FLOW FOR
INCIDENTAL FIRES. IN ADDITION, THE CONTRACTOR IS TO HAVE A TELEPHONE
AVAILABLE TO CALL FOR EMERGENCIES.
3. THE CONTRACTOR SHALL VERIFY THAT EGRESS IS MAINTAINED FOR ALL
OCCUPIED AREAS OF THE BUILDING SITE THROUGHOUT DEMOLITION &
CONSTRUCTION.
4. DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH ALL CODES AND
ORDINANCES AS SET FORTH BY ALL GOVERNING AUTHORITIES.
5. THE CONTRACTOR SHALL CAP ALL MISC. ELECTRICAL, MECHANICAL, PLUMBING
UTILITIES THAT SERVICE THIS AREA AND ARE NOT REQUIRED FOR NEW
CONSTRUCTION OR REQUIRED FOR CONTINUED OPERATION OF EXISTING
SYSTEMS OUT OF VIEW.
6. UPON FINAL REMOVAL OF ALL ROOFING MATERIALS, THE SURROUNDING AREAS
SHALL BE POLICED FOR MISCELLANEOUS DEBRIS TO BE REMOVED. LEAVE THE
ROOF AREA IN A VACUUMED CLEAN CONDITION.
7. ALL DEBRIS SHALL BE REMOVED FROM SITE DAILY TO AN APPROVED DUMPING
FACILITY WHICH MEETS FEDERAL AND LOCAL REQUIREMENTS, OR A CONTRACTOR
SUPPLIED DUMPSTER LOCATED PER OWNER. NO BURNING ON SITE WILL BE
ALLOWED. OWNER'S DUMPSTER MAY NOT BE USED.
8. THE CONTRACTOR SHALL REPAIR, CLEAN, OR REPLACE ANY DAMAGE TO THE
EXISTING ADJACENT FINISH MATERIALS, OTHER STRUCTURES, AND GROUND
AREAS NOT BEING DEMOLISHED.
9. AFTER DEMOLITION THE CONTRACTOR IS TO REPAIR AND PATCH ALL SURFACES
EFFECTED BY DEMOLITION, TO A LIKE NEW OR MATCHING ADJACENT CONDITION.
MATCH BRICK, BLOCK, STUCCO, ETC. AS REQUIRED.
GENERAL DEMOLITION NOTES
EXISTING ROOF DRAINS AND OVERFLOW DRAINS
GPMROOF DRAIN
ROOF
LOCATION
ROOF AREA
SF
DRAIN SIZE
EXISTING
OVERFLOW
DRAIN
OVERFLOW SIZE
RD 1 AREA "A" 1,295 60 4"
RD 2 AREA "A" 1,560 73 4"
RD 3 AREA "A" 1,507 70 4"
RD 4 AREA "A" 1,560 73 4"
RD 5 AREA "A" 1,920 89 4"
RD 6 AREA "A" 1,660 77 4"
RD 7 AREA "A" 273 13 3"
EXISTING ROOF DRAINS AND OVERFLOW DRAINS
GPMROOF DRAIN
ROOF
LOCATION
ROOF AREA
SF
DRAIN SIZE
EXISTING
OVERFLOW
DRAIN
OVERFLOW SIZE
RD8 AREA "A" 258 13 3"
RD 9 AREA "A" 740 35 3"
RD 10 AREA "A" 290 14 3"
RD 11 AREA "A" 290 14 3"
RD 12 AREA "A" 290 14 3"
RD 13 AREA "A" 310 15 3"
RD 14 AREA "B" 455 22 4"
RD 15 AREA "B" 455 22 4"
RD 16 AREA "B" 1,592 75 4"
RD 17 AREA "B" 1,306 62 4"
RD 18 AREA "B" 1,560 73
RD 19 AREA "B" 1,560 73
4"
4"
1. EXISTING MODIFIED BITUMEN ROOF SYSTEM TO BE REMOVED
2. EXISTING LIGHTWEIGHT CONCRETE TO REMAIN
3. EXISTING EPS BOARD TO REMAIN
4. EXISTING 1 1/2" METAL DECK TO REMAIN
EXISTING ROOF AREA "A, B" COMPOSITION
EXISTING STRUCTURE IS FLAT (NO SLOPE)
TABLE 1106.2 EXISTING STORM DRAIN PIPE SIZING
CAPACITY (GPM)
PIPE SIZE
(INCHES)
11178
VERTICAL DRAIN
1/16" PER FOOT
1/8" PER FOOT
1/4" PER FOOT
1/2" PER FOOT
ROOF SQUARE FOOTAGE
ROOF SQUARE FEET # OF SQUARES
BUILT-UP ROOF
SYSTEM AREA "A"
11,018 +/- 111 +/-
BUILT-UP ROOF
SYSTEM AREA "B"
6,858 +/- 69 +/-
NOTE:
ROOF SQUARE FOOTAGE NUMBERS IS ONLY FLAT
ROOF SQUARE FOOTAGE. THIS DOESN'T INCLUDE
PARAPET WALLS, FLASHING, CURBS, ETC.
B22
T H
S T
R E
E T
N O
R T
H
B24 B6
B26B28 B23
B5 B3 B1
B17
B18
B19 B20
B25 B2
B1
NORTH
B1
SOUTH
54TH AVENUE NORTH
B21
P1P2
P3 P4 P5
NO SCALE
KEY PLAN
DRAWING TITLE:
SHEET NO.
WDA PROJ. NO:
OWNER PROJ. NO:
SCALE: REFER TO SHEET
ISSUE/REVISION OF DRAWINGS:
ARCHITECT: AA0002541
ENGINEER: EB 0006884
PHASE:
CHECKED:
DRAWN:
T H
IS
D
O C
U M
E N
T C
O N
T A
IN
S
C O
P Y
R
IG
H T
E D
M A
T E
R
IA
L A
N D
T R
A D
E S
E C
R E
T I N
F O
R M
A T
IO
N
B E
L O
N G
IN
G
E X
C L U
S
IV
E L Y
T O
W
IL
L
IA
M S
O N
D A
C A
R A
S S
O C
IA
T
E S
IN
C
A N
Y U
N A
U T
H O
R
IZ
E D
U S
E
D
IS
C L O
S U
R E
D
IS
S
E M
IN
A
T
IO
N O
R D
U P
L
IC
A T
IO
N
O F
A N
Y O
F T
H E
I N
F O
R M
A T
IO
N
C O
N T
A
IN
E D
H E
R E
IN
M
A Y
R E
S U
L T
I N
L
IA
B
IL
IT
Y
U N
D E
R A
P P
L
IC
A B
W S
/1
/2
:2 :3
P
M
DEMOLITION
ROOF PLAN -
BUILDING 3
th
S t.
N S t.
P e te rs b u rg
F
L
A0.2
2412-02
PERMIT SET
N O
R T
H E
A S
T H
IG
H
S C
H O
O L R
O O
F R
E P
L A
C E
M E
N T
B
U
IL
D
IN
G S
WDA
WDA
3/32" = 1'-0"A0.2
1 DEMOLITION ROOF PLAN - BUILDING 3
NO. DATE DESCRIPTION
1 01/07/25 PH1 SD
2 03/04/25 PH2 DD
3 04/01/25 PH3 100% CD
AREA C
AREA D
AREA E
AREA F
AREA G
AREA G
AREA H
AREA I
RD20
RD21
RD22
RD23
RD24
RD25
RD26
RD27
RD28
RD29
RD30
RD31
RD32
RD33 RD34
RD35
RD36
RD37
RD38
RD39 RD40
26' - 11 1/2" 16' - 0 1/2"
26' - 0"
18' - 8 1/2" 60' - 10"
/2
114' - 8 1/2"
/2
30' - 1"
31' - 8"
32' - 0"
8' - 8"
14' - 3 1/2"
MECHANICAL EQUIPMENT/ EXHAUST HOOD
INDICATES EXISTING WALL BELOW
ROOF LEGEND
DL DOWNLEADERS
PLUMBING VENTS
EXISTING ROOF DRAINS
THRU WALL OVERFLOW SCUPPER LOCATIONS
RD#
REMOVE PLUMBING VENT STACK FLASHING PLYS. CLEAN PPIPE IN PREPARATION FOR
NEW FLASHING. EXTEND PIPING TO MEET THE CODE REQUIREMENT HEIGHT OF 10"
MIN. ABOVE FINISH ROOF, IF NECESSARY.
REMOVE ALL ROOF FLASHING, BLOCKING, TRIM, EXISTING BUILT-UP ROOFING
SYSTEM, INSULATION, CRICKET, BALLAST AND MISCELLANEOUS PLYS, DOWN TO
EXISTING LIGHTWEIGHT CONCRETE DECK, CLEAN DECK FREE OF EMBEDS AND
ADHESIVES, PATCH AREAS FOR FOR SMOOTH UNIFORM SURFACE. CLEAN SURFACE
TO MANUFACTURER'S RECOMMENDATIONS (IF APPLICABLE).
REMOVE DRAIN STRAINER, RING AND RELATED HARDWARE. FULLY CLEAN INNER
SURFACE OF DRAIN BOWL TO REMOVE PITCH, MASTIC, GRAVEL, ASPHALT,
DEBRIS, ETC. AND CLEAN STRAINER RING SURFACE. INSPECT DRAIN BOWL FOR
CRACKS AND/OR DAMAGE. NOTIFY A/E IF DAMAGE IS FOUND. INSPECT DRAIN
BOWL TO PIPE CONNECTION TO ENSURE WATER TIGHT CONDITION. HAVE A
LICENSED PLUMBER, WHO IS FULLY TRAINED IN, AND HAS EXPERIENCE IN,
CLEARING/CLEANING ROOF DRAINS IN THIS SITUATION, AUGER/SNAKE CLEAN
DRAIN PIPE DOWN TO 30' PAST ROOF DRAIN. IF THE DRAIN CANNOT BE CLEANED
DOWN TO 30' THEN VERIFY INNER DRAIN PIPE CONDITION BY VIDEO CAMERA
EQUIPMENT. SUPPLY OWNER & A/E WITH VIDEO DOCUMENTATION IN DIGITAL
FORMAT. WATER TEST TO ENSURE UNRESTRICTED FLOW PRIOR TO INSTALLING
NEW DRAIN COMPONENTS. REPAINT EXPOSED SURFACES/AREAS IF NECESSARY/
NOTIFY OWNER & A/E IMMEDIATELY OF DAMAGE.
REMOVE EXISTING THRU WALL SCUPPER AND FLASHING. PREP OPENING FOR
INSTALLATION OF NEW SCUPPER FLASHING
EXISTING PARAPET CAP METAL, AND FLASHING, CLEATS AND RELATED
FLASHING TO BE REMOVED, TYP. ALL LOCATIONS. INSPECT EXISTING PARAPET
WALL FOR DAMAGE. NOTIFY A/E IF DAMAGE IS FOUND.
EXISTING TWO PIECE WALL REGLET SYSTEM TO BE REMOVED AND REPALCED. TYPICAL ALL
LOCATIONS.
EXISTING MECHANICAL EQUIPMENT TO BE REMOVED AND RE-INSTALLED. REMOVE
FLASHING, SHEATHING, MECHANICAL FASTENERS, SUPPORTS, AND CURB.
CONTRACTOR TO SUPPORT EXISTING MECHANICAL. EQUIPMENT UNTIL NEW CURB IS
INSTALLED. RECONNECT ELECTRICAL AND MECH UNIT ON NEW CURB.
PATCH ANY AND ALL EXISTING LIGHTWEIGHT CONCRETE ROOF SYSTEM AS NEEDED
DUE TO DEMOLITION OF EXISTING CONDITIONS. (TYP. ALL).
ROOF DEMOLITION NOTES:
REMOVE EXISTING SCUTTLE ASSEMBLY, CURB FLASHING AND PLYS, AND CAP
FASTENERS. EXISTING STEEL TO REMAIN. NOTIFY OWNER/ARCHITECT OF ANY
DAMAGE DISCOVERED DURING DEMOLITION. PREP FOR REINSTALL OF NEW ROOF
SCUTTLE ASSEMBLY. EXISTING ROOF LADDER TO BE REMOVED.
EXISTING ELECTRICAL CONDUIT TO REMAIN. EXISTING PITCH PAN TO BE REMOVED.
RELOCATED ELECTRICAL CONDUIT TO NEW STANDS.
EXISTING EDGE FLASHING, CLEATS, AND RELATED FLASHING TO BE REMOVED
TYPICAL ALL LOCATIONS. INSPECT EXISTING WALL BLOCKING FOR DAMAGE. NOTIFY
A/E IF DAMAGE IS FOUND.
CONTRACTOR TO VERIFY EXISTING ANTENNA, PIPE SUPPORT AND ATTACHMENTS ARE
IN USE. CONTRACTOR TO REMOVE ALL EXISTING IF NOT IN USE. IF IN USE
CONTRACTOR TO RERUN WIRES IN BUILDING TO NEW STAND FOR ANTENNAS.
EXISTING ELECTRICAL, PITCH PAN, SUPPORTS, ABANDONED CURBS AND ETC TO BE
REMOVED.
EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. REMOVE FLASHING, SHEATHING,
MECHANICAL FASTENERS, SUPPORTS, CURB, EXISTING ABANDONED ELECTRICAL, AND
PITCH PAN. NEW MECHANICAL EQUIPMENT TO BE INSTALLED (REFER TO MECH.
DRAWINGS). NEW CURB TO BE PROVIDED FOR MECHANICAL EQUIPMENT.
EXISTING WALL MOUNTED ROOF ACCESS LADDERS TO BE REMOVED AND REPLACED.
TYP. ALL LOCATIONS
EXISTING PITCH PAN WITH STEEL ANGLE SUPPORT TO BE REMOVED. PATCH
LIGHTWEIGHT CONCRETE AS REQUIRED FOR NEW ROOF SYSTEM
EXISTING MECHANICAL EQUIPMENT TO BE UN-INSTALLED. CONTRACTOR TO REMOVE
EXISTING EXTENSION CURB, EXISTING CURB. EXISTING CHILL WATER PIPING TO BE
DISCONNECTED TO ACCOMMODATE NEW STRUCTURAL CURB UNIT. EXISTING STEEL
SUPPORTS ADJUST SUPPORT AS REQUIRED.
CONTRACTOR TO REMOVE EXISTING CONDENSATE LINES ON MECHANICAL UNITS AND
REINSTALL WITH NEW PIPE SUPPORTS AFTER NEW CURBS IS INSTALLED AND THE
EXISTING UNITS IS ON THE NEW CURB.
EXISTING GUTTERS TO BE REMOVED AND DOWNLEADERS (D.L.) ALL TO BE
REMOVED AND REINSTALLED AFTER NEW GUTTER IS INSTALLED.
REMOVE EXISTING THRU WALL SCUPPER AND FLASHING. INFILL OPENING TO MATCH
EXISTING CONSTRUCTION.
EXISTING LIGHTNING HORN SYSTEM TO BE UNINSTALLED AND STORED OFF ROOF
UNTILL NEW ROOF SYSTEM IS INSTALLED. ALL EXISTING WIRING TO BE REMOVED
FROM ROOF AND RE-RUN INSIDE BUILDING. CONTRACTOR TO CONTACT HUNTER
ROSS W/ THOR GUARD REGIONAL MANAGER AT 1-(813)-784-4865 or by Email:
Hunterross@verizon.net TO DO ALL WORK TO THE SYSTEM AND PROVIDE A PRICE
FOR THE WORK.
REMOVE ALL ROOF FLASHING, BLOCKING, TRIM, EXISTING BUILT-UP ROOFING
SYSTEM, INSULATION, CRICKET, BALLAST AND MISCELLANEOUS PLYS, AND
LIGHTWEIGHT CONCRETE DOWN TO EXISTING METAL DECK, CLEAN METAL DECK
FREE OF EMBEDS, LIGHTWEIGHT CONCRETE. CLEAN SURFACE OF METAL DECK
AND FLUTES TO MANUFACTURER'S RECOMMENDATIONS.
CONTRACTOR TO REMOVE EXISTING ELEC., PIPE AND RELOCATE TO NEW ROOF
PENETRATION VAULT CURB. COORDINATE WITH OWNER ON LOCATION FOR NEW
VAULT PENETRATION CURB.
EXISTING MOISTURE SATURATED LIGHTWEIGHT CONCRETE IN HATCHED AREAS
ARE TO BE RMEOVED DOWN TO THE EXISTINGMETAL DECK. PREP AREA FOR
INSTALLATION OF NEW LIGHTWEIGHT CONCRETE.
EXISTING GOOSENECK ASSEMBLY TO BE REMOVED. PREP AREA FOR
INSTALLATION OF NEW GOOSENECK ASSMEBLY.
1. EXISTING MODIFIED BITUMEN ROOF SYSTEM TO BE REMOVED
2. EXISTING RECOVERY BOARD TO BE REMOVED
3. EXISTING RIGID INSULATION TO BE REMOVED
4. EXISTING 1 1/2" METAL DECK TO REMAIN
EXISTING ROOF AREA "D" COMPOSITION
EXISTING STRUCTURE IS SLOPED 0.25/12
1. EXISTING MODIFIED BITUMEN ROOF SYSTEM TO BE REMOVED
2. EXISTING LIGHTWEIGHT CONCRETE TO REMAIN EXISTING
3. EXISTING EPS BOARD TO REMAIN
4. EXISTING 1 1/2" METAL DECK TO REMAIN
EXISTING ROOF AREA "E, G - I" COMPOSITION
EXISTING STRUCTURE IS FLAT (NO SLOPE)
1. EXISTING MODIFIED BITUMEN ROOF SYSTEM TO BE REMOVED
2. EXISTING LIGHTWEIGHT CONCRETE TO BE REMOVED
3. EXISTING EPS BOARD TO BE REMOVED
4. EXISTING 1 1/2" METAL DECK TO REMAIN
EXISTING ROOF AREA "F" COMPOSITION
EXISTING STRUCTURE IS FLAT (NO SLOPE)
1. EXISTING MODIFIED BITUMEN ROOF SYSTEM TO BE REMOVED
2. EXISTING RECOVERY BOARD TO BE REMOVED
3. EXISTING TAPERED INSULATION TO BE REMOVED
4. EXISTING 1 1/2" METAL DECK TO REMAIN
EXISTING ROOF AREA "C" COMPOSITION
EXISTING STRUCTURE IS FLAT (NO SLOPE)
1. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF ANY WORK
INDICATED IN THE CONTRACT DOCUMENTS CANNOT BE PERFORMED DUE TO
EXISTING FIELD CONDITIONS. OWNER RESERVES THE RIGHT TO KEEP ANY
MATERIALS FOUND DURING DEMOLITION. SUCH MATERIALS SHALL BE IDENTIFIED
SUCH THAT CONTRACTOR CAN PLACE ASIDE FOR OWNER.
2. DURING DEMOLITION THE CONTRACTOR SHALL PROVIDE HAND HELD FIRE
EXTINGUISHER OR WATER SUPPLY CAPABLE OF 10 GAL./MINUTE FLOW FOR
INCIDENTAL FIRES. IN ADDITION, THE CONTRACTOR IS TO HAVE A TELEPHONE
AVAILABLE TO CALL FOR EMERGENCIES.
3. THE CONTRACTOR SHALL VERIFY THAT EGRESS IS MAINTAINED FOR ALL
OCCUPIED AREAS OF THE BUILDING SITE THROUGHOUT DEMOLITION &
CONSTRUCTION.
4. DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH ALL CODES AND
ORDINANCES AS SET FORTH BY ALL GOVERNING AUTHORITIES.
5. THE CONTRACTOR SHALL CAP ALL MISC. ELECTRICAL, MECHANICAL, PLUMBING
UTILITIES THAT SERVICE THIS AREA AND ARE NOT REQUIRED FOR NEW
CONSTRUCTION OR REQUIRED FOR CONTINUED OPERATION OF EXISTING
SYSTEMS OUT OF VIEW.
6. UPON FINAL REMOVAL OF ALL ROOFING MATERIALS, THE SURROUNDING AREAS
SHALL BE POLICED FOR MISCELLANEOUS DEBRIS TO BE REMOVED. LEAVE THE
ROOF AREA IN A VACUUMED CLEAN CONDITION.
7. ALL DEBRIS SHALL BE REMOVED FROM SITE DAILY TO AN APPROVED DUMPING
FACILITY WHICH MEETS FEDERAL AND LOCAL REQUIREMENTS, OR A CONTRACTOR
SUPPLIED DUMPSTER LOCATED PER OWNER. NO BURNING ON SITE WILL BE
ALLOWED. OWNER'S DUMPSTER MAY NOT BE USED.
8. THE CONTRACTOR SHALL REPAIR, CLEAN, OR REPLACE ANY DAMAGE TO THE
EXISTING ADJACENT FINISH MATERIALS, OTHER STRUCTURES, AND GROUND
AREAS NOT BEING DEMOLISHED.
9. AFTER DEMOLITION THE CONTRACTOR IS TO REPAIR AND PATCH ALL SURFACES
EFFECTED BY DEMOLITION, TO A LIKE NEW OR MATCHING ADJACENT CONDITION.
MATCH BRICK, BLOCK, STUCCO, ETC. AS REQUIRED.
GENERAL DEMOLITION NOTES
ROOF SQUARE FOOTAGE
ROOF SQUARE FEET # OF SQUARES
BUILT-UP ROOF
SYSTEM AREA "C"
4,992 +/- 50 +/-
BUILT-UP ROOF
SYSTEM AREA "D"
2,848 +/- 29 +/-
NOTE:
ROOF SQUARE FOOTAGE NUMBERS IS ONLY FLAT
ROOF SQUARE FOOTAGE. THIS DOESN'T INCLUDE
PARAPET WALLS, FLASHING, CURBS, ETC.
BUILT-UP ROOF
SYSTEM AREA "E"
862 +/- 9 +/-
BUILT-UP ROOF
SYSTEM AREA "F"
1,318 +/- 14 +/-
BUILT-UP ROOF
SYSTEM AREA "G"
4,261 +/- 43 +/-
BUILT-UP ROOF
SYSTEM AREA "H"
7,696 +/- 77 +/-
BUILT-UP ROOF
SYSTEM AREA "I"
1,440 +/- 15 +/-
B22
T H
S T
R E
E T
N O
R T
H
B24 B6
B26B28 B23
B5 B3 B1
B17
B18
B19 B20
B25 B2
B1
NORTH
B1
SOUTH
54TH AVENUE NORTH
B21
P1P2
P3 P4 P5
NO SCALE
KEY PLAN
DRAWING TITLE:
SHEET NO.
WDA PROJ. NO:
OWNER PROJ. NO:
SCALE: REFER TO SHEET
ISSUE/REVISION OF DRAWINGS:
ARCHITECT: AA0002541
ENGINEER: EB 0006884
PHASE:
CHECKED:
DRAWN:
T H
IS
D
O C
U M
E N
T C
O N
T A
IN
S
C O
P Y
R
IG
H T
E D
M A
T E
R
IA
L A
N D
T R
A D
E S
E C
R E
T I N
F O
R M
A T
IO
N
B E
L O
N G
IN
G
E X
C L U
S
IV
E L Y
T O
W
IL
L
IA
M S
O N
D A
C A
R A
S S
O C
IA
T
E S
IN
C
A N
Y U
N A
U T
H O
R
IZ
E D
U S
E
D
IS
C L O
S U
R E
D
IS
S
E M
IN
A
T
IO
N O
R D
U P
L
IC
A T
IO
N
O F
A N
Y O
F T
H E
I N
F O
R M
A T
IO
N
C O
N T
A
IN
E D
H E
R E
IN
M
A Y
R E
S U
L T
I N
L
IA
B
IL
IT
Y
U N
D E
R A
P P
L
IC
A B
W S
/1
/2
:2 :4
P
M
DEMOLITION
ROOF PLAN -
BUILDING 6
th
S t.
N S t.
P e te rs b u rg
F
L
A0.3
2412-02
PERMIT SET
N O
R T
H E
A S
T H
IG
H
S C
H O
O L R
O O
F R
E P
L A
C E
M E
N T
B
U
IL
D
IN
G S
BL / TW
TAW
3/32" = 1'-0"A0.3
1 DEMOLITION ROOF PLAN - BUILDING 6
NO. DATE DESCRIPTION
1 01/07/25 PH1 SD
2 03/04/25 PH2 DD
3 04/01/25 PH3 100% CD
EXISTING ROOF DRAINS AND OVERFLOW DRAINS
GPMROOF DRAIN
ROOF
LOCATION
ROOF AREA
SF
DRAIN SIZE
EXISTING
OVERFLOW
DRAIN
OVERFLOW SIZE
RD 20 AREA "E" 851 40 3" -
RD 21 AREA "F" 2,795 131 6"
RD 22 AREA "G" 410 20 3"
RD 23 AREA "G" 410 20 3"
RD 24 AREA "G" 335 16 3"
RD 25 AREA "G" 335 16 3"
RD 26 AREA "G" 335 16 3"
RD 27 AREA "G" 335 16 3"
RD 28 AREA "G" 2,910 137 6"
RD 29 AREA "G" 1,050 50 4"
RD 30 AREA "H" 720 34 4"
RD 31 AREA "H" 530 25 4"
RD 32 AREA "H" 600 29 4"
RD 33 AREA "H" 660 31 4"
RD 34 AREA "H" 600 29 4"
RD 35 AREA "H" 1,740 82 4"
RD 36 AREA "H" 1,240 59 4"
RD 37 AREA "H" 660 31
RD 38 AREA "H" 670 32
4"
4"
RD 39 AREA "I" 2,600 122 6"
RD 40 AREA "I" 2,450 115 6"
TABLE 1106.2 EXISTING STORM DRAIN PIPE SIZING
CAPACITY (GPM)
PIPE SIZE
(INCHES)
11178
VERTICAL DRAIN
1/16" PER FOOT
1/8" PER FOOT
1/4" PER FOOT
1/2" PER FOOT
DRAWING TITLE:
SHEET NO.
WDA PROJ. NO:
OWNER PROJ. NO:
SCALE: REFER TO SHEET
ISSUE/REVISION OF DRAWINGS:
ARCHITECT: AA0002541
ENGINEER: EB 0006884
PHASE:
CHECKED:
DRAWN:
T H
IS
D
O C
U M
E N
T C
O N
T A
IN
S
C O
P Y
R
IG
H T
E D
M A
T E
R
IA
L A
N D
T R
A D
E S
E C
R E
T I N
F O
R M
A T
IO
N
B E
L O
N G
IN
G
E X
C L U
S
IV
E L Y
T O
W
IL
L
IA
M S
O N
D A
C A
R A
S S
O C
IA
T
E S
IN
C
A N
Y U
N A
U T
H O
R
IZ
E D
U S
E
D
IS
C L O
S U
R E
D
IS
S
E M
IN
A
T
IO
N O
R D
U P
L
IC
A T
IO
N
O F
A N
Y O
F T
H E
I N
F O
R M
A T
IO
N
C O
N T
A
IN
E D
H E
R E
IN
M
A Y
R E
S U
L T
I N
L
IA
B
IL
IT
Y
U N
D E
R A
P P
L
IC
A B
W S
P R
O F
E S
S
IO
N A
L
T H
E O
D O
R E
J W
IL
L
IA
M S
O N
A R
P
E
/1
/2
:2 :4
P
M
DEMOLITION
ROOF PLAN
NOTES -
BUILDING 6
th
S t.
N S t.
P e te rs b u rg
F
L
A0.3.1
2412-02
PERMIT SET
N O
R T
H E
A S
T H
IG
H
S C
H O
O L R
O O
F R
E P
L A
C E
M E
N T
B
U
IL
D
IN
G S
WDA
WDA
NO. DATE DESCRIPTION
1 01/07/25 PH1 SD
2 03/04/25 PH2 DD
3 04/01/25 PH3 100% CD
AREA J
AREA K
AREA L
RD41 RD42
RD43
RD44 RD45
RD46
RD47
RD48 RD49 RD50
RD51
RD52 RD53 RD54 RD55
RD56 RD57 RD58
RD59
18' - 6" 75' - 6"
35' - 7 1/2"
39' - 8"
39' - 9"
69' - 4 1/2"
14' - 1"
6' - 8"
115' - 2 1/2"
3 3
3 3 3
3 3 3 3
3 3 3
11 11
11 11 11
REMOVE PLUMBING VENT STACK FLASHING PLYS. CLEAN PPIPE IN PREPARATION FOR
NEW FLASHING. EXTEND PIPING TO MEET THE CODE REQUIREMENT HEIGHT OF 10"
MIN. ABOVE FINISH ROOF, IF NECESSARY.
REMOVE ALL ROOF FLASHING, BLOCKING, TRIM, EXISTING BUILT-UP ROOFING
SYSTEM, INSULATION, CRICKET, BALLAST AND MISCELLANEOUS PLYS, DOWN TO
EXISTING LIGHTWEIGHT CONCRETE DECK, CLEAN DECK FREE OF EMBEDS AND
ADHESIVES, PATCH AREAS FOR FOR SMOOTH UNIFORM SURFACE. CLEAN SURFACE
TO MANUFACTURER'S RECOMMENDATIONS (IF APPLICABLE).
REMOVE DRAIN STRAINER, RING AND RELATED HARDWARE. FULLY CLEAN INNER
SURFACE OF DRAIN BOWL TO REMOVE PITCH, MASTIC, GRAVEL, ASPHALT,
DEBRIS, ETC. AND CLEAN STRAINER RING SURFACE. INSPECT DRAIN BOWL FOR
CRACKS AND/OR DAMAGE. NOTIFY A/E IF DAMAGE IS FOUND. INSPECT DRAIN
BOWL TO PIPE CONNECTION TO ENSURE WATER TIGHT CONDITION. HAVE A
LICENSED PLUMBER, WHO IS FULLY TRAINED IN, AND HAS EXPERIENCE IN,
CLEARING/CLEANING ROOF DRAINS IN THIS SITUATION, AUGER/SNAKE CLEAN
DRAIN PIPE DOWN TO 30' PAST ROOF DRAIN. IF THE DRAIN CANNOT BE CLEANED
DOWN TO 30' THEN VERIFY INNER DRAIN PIPE CONDITION BY VIDEO CAMERA
EQUIPMENT. SUPPLY OWNER & A/E WITH VIDEO DOCUMENTATION IN DIGITAL
FORMAT. WATER TEST TO ENSURE UNRESTRICTED FLOW PRIOR TO INSTALLING
NEW DRAIN COMPONENTS. REPAINT EXPOSED SURFACES/AREAS IF NECESSARY/
NOTIFY OWNER & A/E IMMEDIATELY OF DAMAGE.
REMOVE EXISTING THRU WALL SCUPPER AND FLASHING. PREP OPENING FOR
INSTALLATION OF NEW SCUPPER FLASHING
EXISTING PARAPET CAP METAL, AND FLASHING, CLEATS AND RELATED
FLASHING TO BE REMOVED, TYP. ALL LOCATIONS. INSPECT EXISTING PARAPET
WALL FOR DAMAGE. NOTIFY A/E IF DAMAGE IS FOUND.
EXISTING TWO PIECE WALL REGLET SYSTEM TO BE REMOVED AND REPALCED. TYPICAL ALL
LOCATIONS.
EXISTING MECHANICAL EQUIPMENT TO BE REMOVED AND RE-INSTALLED. REMOVE
FLASHING, SHEATHING, MECHANICAL FASTENERS, SUPPORTS, AND CURB.
CONTRACTOR TO SUPPORT EXISTING MECHANICAL. EQUIPMENT UNTIL NEW CURB IS
INSTALLED. RECONNECT ELECTRICAL AND MECH UNIT ON NEW CURB.
PATCH ANY AND ALL EXISTING LIGHTWEIGHT CONCRETE ROOF SYSTEM AS NEEDED
DUE TO DEMOLITION OF EXISTING CONDITIONS. (TYP. ALL).
ROOF DEMOLITION NOTES:
REMOVE EXISTING SCUTTLE ASSEMBLY, CURB FLASHING AND PLYS, AND CAP
FASTENERS. EXISTING STEEL TO REMAIN. NOTIFY OWNER/ARCHITECT OF ANY
DAMAGE DISCOVERED DURING DEMOLITION. PREP FOR REINSTALL OF NEW ROOF
SCUTTLE ASSEMBLY. EXISTING ROOF LADDER TO BE REMOVED.
EXISTING ELECTRICAL CONDUIT TO REMAIN. EXISTING PITCH PAN TO BE REMOVED.
RELOCATED ELECTRICAL CONDUIT TO NEW STANDS.
EXISTING EDGE FLASHING, CLEATS, AND RELATED FLASHING TO BE REMOVED
TYPICAL ALL LOCATIONS. INSPECT EXISTING WALL BLOCKING FOR DAMAGE. NOTIFY
A/E IF DAMAGE IS FOUND.
CONTRACTOR TO VERIFY EXISTING ANTENNA, PIPE SUPPORT AND ATTACHMENTS ARE
IN USE. CONTRACTOR TO REMOVE ALL EXISTING IF NOT IN USE. IF IN USE
CONTRACTOR TO RERUN WIRES IN BUILDING TO NEW STAND FOR ANTENNAS.
EXISTING ELECTRICAL, PITCH PAN, SUPPORTS, ABANDONED CURBS AND ETC TO BE
REMOVED.
EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. REMOVE FLASHING, SHEATHING,
MECHANICAL FASTENERS, SUPPORTS, CURB, EXISTING ABANDONED ELECTRICAL, AND
PITCH PAN. NEW MECHANICAL EQUIPMENT TO BE INSTALLED (REFER TO MECH.
DRAWINGS). NEW CURB TO BE PROVIDED FOR MECHANICAL EQUIPMENT.
EXISTING WALL MOUNTED ROOF ACCESS LADDERS TO BE REMOVED AND REPLACED.
TYP. ALL LOCATIONS
EXISTING PITCH PAN WITH STEEL ANGLE SUPPORT TO BE REMOVED. PATCH
LIGHTWEIGHT CONCRETE AS REQUIRED FOR NEW ROOF SYSTEM
EXISTING MECHANICAL EQUIPMENT TO BE UN-INSTALLED. CONTRACTOR TO REMOVE
EXISTING EXTENSION CURB, EXISTING CURB. EXISTING CHILL WATER PIPING TO BE
DISCONNECTED TO ACCOMMODATE NEW STRUCTURAL CURB UNIT. EXISTING STEEL
SUPPORTS ADJUST SUPPORT AS REQUIRED.
CONTRACTOR TO REMOVE EXISTING CONDENSATE LINES ON MECHANICAL UNITS AND
REINSTALL WITH NEW PIPE SUPPORTS AFTER NEW CURBS IS INSTALLED AND THE
EXISTING UNITS IS ON THE NEW CURB.
EXISTING GUTTERS TO BE REMOVED AND DOWNLEADERS (D.L.) ALL TO BE
REMOVED AND REINSTALLED AFTER NEW GUTTER IS INSTALLED.
REMOVE EXISTING THRU WALL SCUPPER AND FLASHING. INFILL OPENING TO MATCH
EXISTING CONSTRUCTION.
EXISTING LIGHTNING HORN SYSTEM TO BE UNINSTALLED AND STORED OFF ROOF
UNTILL NEW ROOF SYSTEM IS INSTALLED. ALL EXISTING WIRING TO BE REMOVED
FROM ROOF AND RE-RUN INSIDE BUILDING. CONTRACTOR TO CONTACT HUNTER
ROSS W/ THOR GUARD REGIONAL MANAGER AT 1-(813)-784-4865 or by Email:
Hunterross@verizon.net TO DO ALL WORK TO THE SYSTEM AND PROVIDE A PRICE
FOR THE WORK.
REMOVE ALL ROOF FLASHING, BLOCKING, TRIM, EXISTING BUILT-UP ROOFING
SYSTEM, INSULATION, CRICKET, BALLAST AND MISCELLANEOUS PLYS, AND
LIGHTWEIGHT CONCRETE DOWN TO EXISTING METAL DECK, CLEAN METAL DECK
FREE OF EMBEDS, LIGHTWEIGHT CONCRETE. CLEAN SURFACE OF METAL DECK
AND FLUTES TO MANUFACTURER'S RECOMMENDATIONS.
CONTRACTOR TO REMOVE EXISTING ELEC., PIPE AND RELOCATE TO NEW ROOF
PENETRATION VAULT CURB. COORDINATE WITH OWNER ON LOCATION FOR NEW
VAULT PENETRATION CURB.
EXISTING MOISTURE SATURATED LIGHTWEIGHT CONCRETE IN HATCHED AREAS
ARE TO BE RMEOVED DOWN TO THE EXISTINGMETAL DECK. PREP AREA FOR
INSTALLATION OF NEW LIGHTWEIGHT CONCRETE.
EXISTING GOOSENECK ASSEMBLY TO BE REMOVED. PREP AREA FOR
INSTALLATION OF NEW GOOSENECK ASSMEBLY.
MECHANICAL EQUIPMENT/ EXHAUST HOOD
INDICATES EXISTING WALL BELOW
ROOF LEGEND
DL DOWNLEADERS
PLUMBING VENTS
EXISTING ROOF DRAINS
THRU WALL OVERFLOW SCUPPER LOCATIONS
RD#
EXISTING ROOF DRAINS AND OVERFLOW DRAINS
GPMROOF DRAIN
ROOF
LOCATION
ROOF AREA
SF
DRAIN SIZE
EXISTING
OVERFLOW
DRAIN
OVERFLOW SIZE
RD 41 AREA "J" 1,650 78 4"
RD 42 AREA "J" 1,780 84 4"
RD 43 AREA "J" 340 16 3"
RD 44 AREA "J" 1,876 88 4"
RD 45 AREA "J" 1,480 70 4"
RD 46 AREA "J" 602 29 4"
RD 47 AREA "K" 1,825 86 4"
EXISTING ROOF DRAINS AND OVERFLOW DRAINS
GPMROOF DRAIN
ROOF
LOCATION
ROOF AREA
SF
DRAIN SIZE
EXISTING
OVERFLOW
DRAIN
OVERFLOW SIZE
RD 48 AREA "L" 988 47 4"
RD 49 AREA "L" 1,106 52 4"
RD 50 AREA "L" 1,178 56 4"
RD 51 AREA "L" 1,536 72 4"
RD 52 AREA "L" 988 47 4"
RD 53 AREA "L" 1,106 52 4"
RD 54 AREA "L" 1,106 52 4"
RD 55 AREA "L" 1,250 59 4"
RD 56 AREA "L" 988 47 4"
RD 57 AREA "L" 1,106 52 4"
RD 58 AREA "L" 1,164 55 4"
RD 59 AREA "L" 1,320 62 4"
TABLE 1106.2 EXISTING STORM DRAIN PIPE SIZING
CAPACITY (GPM)
PIPE SIZE
(INCHES)
11178
VERTICAL DRAIN
1/16" PER FOOT
1/8" PER FOOT
1/4" PER FOOT
1/2" PER FOOT
1. EXISTING MODIFIED BITUMEN ROOF SYSTEM TO BE REMOVED
2. EXISTING LIGHTWEIGHT CONCRETE TO BE REMOVED
3. EXISTING EPS BOARD TO BE REMOVED
4. EXISTING 1 1/2" METAL DECK TO REMAIN
NOTE: ALTERNATE #1: ROOF AREA L - EXISTING LIGHTWEIGHT
CONCRETE AND POLYSTYRENE INSULATION TO REMAIN.
EXISTING MODIFIED BTIUMEN ROOF SYSTEM TO BE
REMOVED.
EXISTING ROOF AREA "J, K, L" COMPOSITION
EXISTING STRUCTURE IS FLAT (NO SLOPE)
ROOF SQUARE FOOTAGE
ROOF SQUARE FEET # OF SQUARES
BUILT-UP ROOF
SYSTEM AREA "J"
7,573 +/- 76 +/-
BUILT-UP ROOF
SYSTEM AREA "K"
2,174+/- 22 +/-
NOTE:
ROOF SQUARE FOOTAGE NUMBERS IS ONLY FLAT
ROOF SQUARE FOOTAGE. THIS DOESN'T INCLUDE
PARAPET WALLS, FLASHING, CURBS, ETC.
BUILT-UP ROOF
SYSTEM AREA "L"
12,544+/- 126 +/-
B22
T H
S T
R E
E T
N O
R T
H
B24 B6
B26 B28
B23
B5 B3 B1
B17
B18
B19 B20
B25 B2
B1
NORTH
B1
SOUTH
54TH AVENUE NORTH
B21
P1P2
P3 P4 P5
NO SCALE
KEY PLAN
DRAWING TITLE:
SHEET NO.
WDA PROJ. NO:
OWNER PROJ. NO:
SCALE: REFER TO SHEET
ISSUE/REVISION OF DRAWINGS:
ARCHITECT: AA0002541
ENGINEER: EB 0006884
PHASE:
CHECKED:
DRAWN:
T H
IS
D
O C
U M
E N
T C
O N
T A
IN
S
C O
P Y
R
IG
H T
E D
M A
T E
R
IA
L A
N D
T R
A D
E S
E C
R E
T I N
F O
R M
A T
IO
N
B E
L O
N G
IN
G
E X
C L U
S
IV
E L Y
T O
W
IL
L
IA
M S
O N
D A
C A
R A
S S
O C
IA
T
E…