NAFQJ323B0001 AM-0004 Specifications.pdf
PDF 619 KB Posted
- Attached to
- NAF MWR Army Lodging, Camp Zama, Japan
- Solicitation number
- NAFQJ3-23-B-0001
About this file
This document is a LEED v4 checklist for a proposed Army Lodging Facility at Camp Zama, Japan to be constructed under solicitation NAFQJ3-23-B-0001. The project will include construction of a new seven-story building consisting of 103 guest suites, support facilities such as elevators, mechanical and electrical rooms, and site work including vehicle parking areas and walkways. The checklist reviews the potential credits under LEED v4 for Building Design and Construction and notes status of achieving various prerequisites and credits. Waivers are noted where Department of Defense requirements preclude certain credits. The Army Corps of Engineers Japan District is the contracting agency seeking construction of the Army Lodging Facility.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEED v4 for BD+C: Hospitality Project Checklist Project Name: Army Lodging Facility, Camp Zama
Date: 5/26/23 (RTA) - Revised 6/22/23
Y ? N D/C Status 1 Credit 1 D
5 1 10 16 Status 0 Credit 16 D
1 Credit 1 D 2 Credit 2 D
2 3 Credit 5 D 1 4 Credit 5 D
1 Credit 1 D 1 Credit 1 D
1 Credit Green Vehicles 1 D
7 0 3 10 Status Y Prereq Required C
1 Credit 1 D 2 Credit 2 D 1 Credit 1 D
3 Credit 3 D 2 Credit 2 D 1 Credit 1 D
7 0 4 11 Status Y Prereq Required D Y Prereq Required D Y Prereq Building-Level Water Metering Required D 2 Credit 2 D 5 1 Credit 6 D
2 Credit 2 D 1 Credit Water Metering 1 D
12 0 21 33 Status Y Prereq Required C Y Prereq Required D Y Prereq Required D Y Prereq Required D
6 Credit 6 C 11 7 Credit 18 D
1 Credit 1 D 2 Credit 2 C
Revised calculated energy cost savings is 28.8%.
DOD Waiver on sharing data. Trend will be provided via BAS.
Understand Electrical Demand Response program is not available at Zama.
V4.1 (ECB #10) Reviewed, not achievable due to soil condition. Design retains 100% undergrnd.
DOD Waiver-CIR allows Gov to be CxA.
DOD Waiver - sharing of data not required.
Not requested by stakeholder.
DOD Waiver - sharing of data not required.
Option 1 - No irrigation [RP] Calculated reduction is 49.81.
V4.1 (ECB #10) None in this project.
Metering water into bldg. Not metering 2 subsystems, as reqd.
Reduced Parking Footprint
Construction Activity Pollution Prevention
Site Assessment
Rainwater Management Open Space
Water Efficiency
Minimum Energy Performance
Outdoor Water Use Reduction
Advanced Energy Metering Demand Response
Fundamental Commissioning and Verification Energy and Atmosphere
Enhanced Commissioning
Outdoor Water Use Reduction
Heat Island Reduction Light Pollution Reduction
Integrative Process
Location and Transportation
Sensitive Land Protection High Priority Site
Sustainable Sites
Site Development - Protect or Restore Habitat
LEED for Neighborhood Development Location
Surrounding Density and Diverse Uses Access to Quality Transit Bicycle Facilities
V4.1 (ECB #10) - extensive analysis not incorporated.
Option 1 previously developed site.
Neither option 1, 2 or 3 apply to this site.
Optimize Energy Performance
Building-Level Energy Metering Fundamental Refrigerant Management
Cooling Tower Water Use Indoor Water Use Reduction
Indoor Water Use Reduction
Option 2 achievable (2 pts). Option 1 (3 pts) not acheivable, adjacent density appears low.
High frequency of route trips req'd, will be challenging to achieve.
V4.1 (ECB #10) Achievement subject to GBCI accepting number of spaces in bicycle storage.
Appears achievable. Requires designated carpool spaces (3) in preferred location.
JDDG states HPSB 'Green Vehicles' reqt not to be pursued.
Option 1, non-roof measures & high-reflectance roof.
Option 2 appears achievable, for uplighting and light tresspass.
Option 1 - No irrigation DOD Waiver, Gender ratio: N/A
Appears achievable Option 1 appears achievable. [RP] Appears achievable
Army Lodging Facility Camp Zama, Japan
NAFQJ3-23-B-0001
Final RTA Submittal
ATTACHMENT 01 33 29-B Page 1 zimemi Strikethrough 5/26/23 (RTA) - Revised 6/22/23 zimemi Text Box 1/3/2024 zimemi Text Box
AM-0004
zimemi Pen zimemi Text Box CxA to be provided by KTR.
j2ee9kny Line j2ee9kny Line
3 Credit 3 D 1 Credit 1 D
2 Credit 2 C
2 1 10 13 Status Y Prereq Required D Y Prereq Required C
5 Credit 5 C
2 Credit 2 C
1 1 Credit 2 C 2 Credit Building Product Disclosure and Optimization - Material Ingredients 2 C
2 Credit 2 C
8 4 4 Indoor Environmental Quality 16 Status Y Prereq Required D Y Prereq Required D 1 1 Credit 2 D
3 Credit 3 C 1 Credit Construction Indoor Air Quality Management Plan 1 C 2 Credit 2 C 1 Credit 1 D 1 1 Credit 2 D
3 Credit 3 D 1 Credit 1 D 1 Credit 1 D
4 2 0 Innovation 6 Status 1 Credit 5 D
1 Credit Innovation or Pilot D 1 Credit Innovation or Pilot D
1 Credit Innovation or Pilot or Exemplary C 1 Credit Innovation or Pilot or Exemplary D 1 Credit 1 D/C
4 0 1 Regional Priority 4 Status 1 Credit Regi SSc4 Rainwater Management D
1 Credit Regi WEc1 Outdoor Water Use Reduction 1 D 1 Credit Regi WEc2 Indoor Water Use Reduction 1 D 1 Credit Regi EAc2 Optimize energy performance 1 D 1 Credit Regi SSc2 Site Devel - protect or restore habitat 1 D
Credit Regi EAc1 Enhanced commissioning C
50 8 53 TOTALS Possible Points: 110
Not pursuing, 2 pts required.
At 2 pts At 4 pts
Not pursuing
Certified: 40 to 49 points, Silver: 50 to 59 points, Gold: 60 to 79 points, Platinum: 80 to 110
V4.1 (ECB #10) pursuing 2 out of 3 reqts.
Green Cleaning program of Army Lodging
LEED AP w/ specialty on design. Contractor team also required to have LEED AP w/ specialty.
Environmental Ed program of Army Lodging Integrated Pest Management
IEQc8 exemplary appears achievable.
MRc5 exemplary, if contractor achieves Option 2 along with Option 1.
At 8 pts At 2 pts
LEED Accredited Professional
V4.1 (ECB #10) Option 1/Path 1, or Option 2, acceptable to JED
Option 1, ASHRAE 55 Option 1 (public spaces) achievable, Option 2 (4 of 8 strategies) to be investigated.
Per VE direction, guestroom window size reduced to code minimum, credit not achievable.
2 of 4 kinds of views appear to be met.
Option 1, ASHRAE 62.1 Non-smoking building. No smoking exterior signage to be provided.
Option 1, Mechanically ventilated space.
V4.1 (ECB #10) appears more achievable. Requirements in spec.
V4.1 (ECB #10) v4.1 has East Asia equivalent for filtration.
V4.1 (ECB #10) Option 1 nor 2 readily achievable. Not available from Japanese manufacturers.
V4.1 (ECB #10) Certified wood & recycled content specified, products to pursue for compliance.
V4.1 (ECB #10) Option 1 nor 2 readily achievable. Not available from Japanese manufacturers.
JDDG states HPSB 'Green Power & Carbon Offset' reqt not to be pursued.
Plan from contactor required in 01 74 19 Not pursued, available software tools only have database for North America.
procluded by LCCA. At Charrette, confirmed not to be pursued.
Equipment & refrigerant selections are compliant.
Green Power and Carbon Offsets
Renewable Energy Production
Enhanced Indoor Air Quality Strategies
Materials and Resources Storage and Collection of Recyclables Construction and Demolition Waste Management Planning Building Life-Cycle Impact Reduction
Building Product Disclosure and Optimization - Environmental Product Declarations
Quality Views Acoustic Performance
Innovation or Pilot
Low-Emitting Materials
Indoor Air Quality Assessment Thermal Comfort Interior Lighting Daylight
Building Product Disclosure and Optimization - Sourcing of Raw Materials
Construction and Demolition Waste Management
Minimum Indoor Air Quality Performance Environmental Tobacco Smoke Control
Enhanced Refrigerant Management
Army Lodging Facility Camp Zama, Japan
NAFQJ3-23-B-0001
Final RTA Submittal
ATTACHMENT 01 33 29-B Page 2 zimemi Snapshot zimemi Text Box
AM-0004
Attachment 01 33 29-B
File details come from the government source that posted it. Updated .