P683 Amendment 0007 Specs.pdf
PDF 281 KB Posted
- Solicitation number
- N6945026R0005
About this file
These documents are technical specifications and hardware schedules for the P-683 Engine Repair Facility, establishing requirements for door hardware and high-security fencing systems. The specifications are organized into two primary sections revised by Amendment 0007.
Section 08 71 00 (Door Hardware) mandates comprehensive door hardware systems including continuous hinges, locks, exit devices, closers, thresholds, weatherstripping, and access control components for a multi-building facility. The specification references ANSI/BHMA standards for locks, hinges, closers, and auxiliary hardware, along with NFPA standards for fire doors and life safety. Hardware finishes must conform to BHMA 630 (satin stainless steel) or BHMA 626 (satin chromium plated), with stainless steel required for exterior applications. The specification includes 32 detailed hardware sets tailored to specific door applications, ranging from exterior glazed aluminum entrance doors with card readers to interior smoke-rated doors with fire ratings. Each set specifies manufacturers (McKinney, Pemko, Rixson, ASSA ABLOY, Sargent, Adams Rite, Medeco, HES, and others), catalog numbers, finishes, and quantities. Submittals require government approval (G classification) for manufacturer's detail drawings, hardware schedules, keying systems, and product data. The specification mandates electrified hardware compatibility with NFPA 70 electrical requirements, fail-secure locks, power transfer hinges for electrified mortise locks, and integration with card readers and keypads per Base Security Requirements.
Section 32 31 13.53 (High-Security Fences and Gates) specifies chain-link and ornamental fence systems with aluminum-coated steel wire fabric (9 gauge, 2-inch diamond mesh), galvanized steel posts conforming to ASTM F1083, and barbed wire supporting arms. Gate assemblies must comply with ASTM F900 (swing gates) or ASTM F1184 (sliding gates) with electro-mechanical solenoid-actuated locks rated for 120V AC, 60Hz continuous duty operation. Installation requires posts set in concrete at specified depths, fabric tensioned to eliminate sag, and grounding systems meeting National Electric Safety Code (NESC) IEEE C2-Section 92E and NFPA-70 Article 250-190, with ground resistance not exceeding 25 ohms. The specification mandates fabric height of 7 feet, post rigidity testing via 50-pound horizontal force application, and fabric deflection testing limited to 2.5 inches. Submittals include fence installation drawings, product data for all components, certificates for chain-link fabric and barbed wire, and operating/maintenance instructions. All fasteners, hinges, and hardware must be galvanized or stainless steel to prevent corrosion in the outdoor security fence environment.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P-683 Engine Repair Facility 1817922
SECTION 08 71 00
DOOR HARDWARE
02/16, CHG 4: 02/22
Revised by Amendment 0007
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM E283 (2019) Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
ASTM F883 (2013; R 2022) Standard Performance Specification for Padlocks
BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
ANSI/BHMA A156.1 (2021) Butts and Hinges
ANSI/BHMA A156.2 (2022) Bored and Preassembled Locks and Latches
ANSI/BHMA A156.3 (2020) Exit Devices
ANSI/BHMA A156.4 (2024) Door Controls - Closers
ANSI/BHMA A156.5 (2020) Cylinder and Input Devices for Locks
ANSI/BHMA A156.6 (2021) Architectural Door Trim
ANSI/BHMA A156.7 (2016) Template Hinge Dimensions
ANSI/BHMA A156.8 (2021) Door Controls - Overhead Stops and Holders
ANSI/BHMA A156.10 (2024) Power Operated Pedestrian Doors
ANSI/BHMA A156.13 (2022) Mortise Locks & Latches Series 1000
ANSI/BHMA A156.15 (2021) Release Devices Closer Holder, Electromagnetic and Electromechanical
ANSI/BHMA A156.16 (2023) Auxiliary Hardware
ANSI/BHMA A156.18 (2020) Materials and Finishes
ANSI/BHMA A156.19 (2013) Power Assist & Low Energy Power Operated Doors
SECTION 08 71 00 Page 1
AMENDMENT 0007
ANSI/BHMA A156.21 (2019) Thresholds
ANSI/BHMA A156.22 (2021) Gasketing
ANSI/BHMA A156.23 (2010) Electromagnetic Locks
ANSI/BHMA A156.24 (2012) Delayed Egress Locking Systems
ANSI/BHMA A156.25 (2013) Electrified Locking Devices
ANSI/BHMA A156.26 (2012) Continuous Hinges
ANSI/BHMA A156.29 (2012) Exit Locks, Exit Alarms, Alarms for Exit Devices
ANSI/BHMA A156.30 (2014) High Security Cylinders
ANSI/BHMA A156.31 (2013) Electric Strikes and Frame Mounted Actuators
ANSI/BHMA A156.36 (2010) Auxiliary Locks
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 70 (2023; ERTA 1 2024; TIA 24-1; TIA 25-2)
National Electrical Code
NFPA 72 (2022; ERTA 22-1) National Fire Alarm and Signaling Code
NFPA 80 (2025) Standard for Fire Doors and Other Opening Protectives
NFPA 101 (2024) Life Safety Code
NFPA 252 (2022) Standard Methods of Fire Tests of Door Assemblies
STEEL DOOR INSTITUTE (SDI/DOOR)
SDI/DOOR A250.8 (2023) Specifications for Standard Steel Doors and Frames
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
UNDERWRITERS LABORATORIES (UL)
UL Bld Mat Dir (updated continuously online) Building Materials Directory
1.2 SUBMITTALS
Government approval is required for submittals with a "G" classification.
SECTION 08 71 00 Page 2
Submittals with an "S" are for inclusion in the Sustainability eNotebook, in accordance with section 01 33 29 SUSTAINABILITY REQUIREMENTS AND REPORTING. Submittals not having a "G" or "S" classification are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Manufacturer's Detail Drawings ; G
Verification of Existing Conditions ; G
Hardware Schedule ; G
Keying System ; G
SD-03 Product Data
Hardware Items ; G
SD-08 Manufacturer's Instructions
Installation
SD-10 Operation and Maintenance Data
Hardware Schedule Items, Data Package 1; G
SD-11 Closeout Submittals
Key Bitting
1.3 SHOP DRAWINGS
Submit manufacturer's detail drawings indicating all hardware assembly components and interface with adjacent construction. Indicate power components and wiring coordination for electrified hardware. Base shop drawings on verified field measurements and include verification of existing conditions .
1.4 PRODUCT DATA
Indicate fire-ratings at applicable components. Provide documentation of ABA/ADA accessibility compliance of applicable components, as required by 36 CFR 1191 Appendix D - Technical.
1.5 HARDWARE SCHEDULE
Provide Hardware Item List and Hardware Schedule containing the following information, and additional information as needed to identify the complete make up of each hardware set and its application to each opening:
1.5.1 Hardware Item List:
a. Hardware Type
b. Item Number
SECTION 08 71 00 Page 3
c. Quantity
d. Size(s)
e. Reference Publication / Type Number
f. Manufacturer's Name / Catalog Number
g. Key Control Symbols
h. UL Mark (If fire rated and listed)
i. BHMA Finish(es)
j. Remarks
1.5.2 Hardware Schedule
a. Hardware Set Number
b. Opening Number(s)
c. Opening Description (single/double leaf, hand, size, door/frame material)
d. Fire Rating
e. Sound Rating
f. Hardware Items
g. Quantity
h. Size
i. BHMA Finish
j. Remarks
In addition, submit hardware schedule data package 1 in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA.
1.6 KEY BITTING CHART REQUIREMENTS
1.6.1 Requirements
Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:
a. Complete listing of all keys (e.g. AA1 and AA2).
b. Complete listing of all key cuts (AA1-123456, AA2-123458).
c. Tabulation showing which key fits which door.
d. Copy of floor plan showing doors and door numbers.
e. Listing of 20 percent more key cuts than are presently required in each master system.
SECTION 08 71 00 Page 4
1.7 QUALITY ASSURANCE
1.7.1 Hardware Manufacturers and Modifications
Provide, as far as feasible, locks, hinges, and closers of one lock, hinge, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.
1.7.2 Key Shop Drawings Coordination Meeting
Prior to the submission of the key shop drawing, the Contracting Officer, Contractor, Door Hardware Subcontractor, using Activity and Base Locksmith must meet to discuss and coordinate key requirements for the facility.
1.8 DELIVERY, STORAGE, AND HANDLING
Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown on hardware schedule.
Deliver permanent keys and removable cores to the Contracting Officer, either directly or by certified mail. Deliver construction master keys with the locks.
PART 2 PRODUCTS
2.1 TEMPLATE HARDWARE
Hardware applied to metal or to prefinished doors must be manufactured using a template. Provide templates to door and frame manufacturers in accordance with ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.
2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS
Provide all hardware necessary to meet the requirements of NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, NFPA 252 for fire tests of door assemblies, ABA/ADA accessibility requirements, and all other requirements indicated, even if such hardware is not specifically mentioned in paragraph HARDWARE SCHEDULE. Provide Underwriters Laboratories, Inc. labels for such hardware in accordance with UL Bld Mat Dir or equivalent labels in accordance with another testing laboratory approved in writing by the Contracting Officer.
2.3 HARDWARE ITEMS
*****Amendment 0003 Clearly and permanently mark with the manufacturer's name or trademark, hinges, pivots, locks, latches, exit devices, bolts and closers where the identifying mark is visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover. Coordinate electrified door hardware components with corresponding components. ***Amendment 0003*****
2.3.1 Hinges
Provide in accordance with ANSI/BHMA A156.1 . Provide hinges that are 4-1/2 by 4-1/2 inch unless otherwise indicated. Construct loose pin hinges for interior doors and reverse-bevel exterior doors so that pins are non-removable when door is closed. Other anti-friction bearing hinges
SECTION 08 71 00 Page 5 may be provided in lieu of ball bearing hinges.
2.3.2 Continuous Hinges
Where continuous hinges are required, provide in accordance with
ANSI/BHMA A156.26 .
2.3.3 Locks and Latches
2.3.3.1 Mortise Locks and Latches
Provide in accordance with ANSI/BHMA A156.13 , Series 1000, Operational Grade 1, Security Grade 2. Provide knobs and roses of mortise locks with screwless shanks and no exposed screws.
2.3.3.2 Bored Locks and Latches
Provide in accordance with ANSI/BHMA A156.2 , Series 4000, Grade 1.
2.3.3.3 Auxiliary Locks
Provide in accordance with ANSI/BHMA A156.36 , Grade 1.
2.3.3.4 Combination Locks
Heavy-duty, mechanical combination lockset with five push buttons, standard sized knobs, 3/4 inch deadlocking latch, 2-3/4 inch backset.
Locks to operate by pressing two or more of the buttons in unison or individually in the proper sequence. Inside knob operates the latch.
Provide a keyed cylinder on the interior to permit setting the combination.
Provide a keyed removable core cylinder on the exterior to permit bypassing the combination.
2.3.4 Exit Devices
Provide in accordance with ANSI/BHMA A156.3 , Grade 1. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with mortise and vertical rod devices. Provide touch bars in lieu of conventional crossbars and arms.
2.3.5 Exit Locks With Alarm
Provide in accordance with ANSI/BHMA A156.3 and ANSI/BHMA A156.29 , Type E0431 (with full width horizontal actuating bar) for single doors; Type E0431 (with actuating bar) or E0471 (with actuating bar and top and bottom bolts, both leaves active) for pairs of doors, unless otherwise specified.
Provide terminals for connection to remote indicating panel. Provide door alarms integrated with the fire alarm system in accordance with
NFPA 72 .
2.3.6 Cylinders and Cores
Provide cylinders and cores for new locks, including locks provided under other sections of this specification. Provide cylinders and cores with six pin tumblers. Provide cylinders from the products of one manufacturer, and provide cores from the products of one manufacturer. Rim cylinders, mortise cylinders, and knobs of bored locksets have interchangeable cores which are removable by special control keys. Stamp each interchangeable core with a key control symbol in a concealed place on the core.
SECTION 08 71 00 Page 6
2.3.6.1 High Security Cylinders
Provide in accordance with ANSI/BHMA A156.30 , security level A for all high security cylinder components.
2.3.7 Push Button Mechanisms
Provide in accordance with ANSI/BHMA A156.5 , Grade 1.
2.3.8 Electrified Hardware
Comply with the requirements of NFPA 70 for wiring of electrified hardware.
2.3.8.1 Electric Strikes and Frame Mounted Actuators
Provide in accordance with ANSI/BHMA A156.31 , Grade 1. Provide electric strikes and actuators as required to meet operational requirements.
Provide electric strikes that remain secure during power failure. Provide a separate power supply for electric strikes, other locking devices and ancillary parts. Provide strikes and actuators with a minimum opening force of 2300 pounds .
Provide facility interface devices that use direct current (dc) power to energize the solenoids. Provide electric strikes and actuators that incorporate end-of-line resistors to facilitate line supervision by the system. If not incorporated into the electric strike or local controller, provide metal oxide resistors (MOVs) to protect the controller from reverse current surges.
2.3.8.1.1 Solenoid
Provide actuating solenoid for strikes and actuators that are rated for continuous duty, cannot dissipate more than 12 Watts and must operate on 12 or 24 Volts dc. Inrush current cannot exceed 1 ampere and the holding current cannot be greater than 500 milliamperes. Actuating solenoid must move from fully secure to fully open positions in less than 500 milliseconds.
2.3.8.1.2 Signal Switches
Provide strikes and actuators with signal switches to indicate to the system when the bolt is not engaged or the strike mechanism is unlocked.
Signal switches must report a forced entry to the system.
2.3.8.1.3 Tamper Resistance
Provide strike guards that prevent tampering with the latch bolt of the locking hardware or the latch bolt keeper of the electric strike. Strike guards to bolt through the door using tamper resistant screws. Provide strike guards made of 1/8 inch thick brass and that are 11-1/14 inch high by 1-5/8 inch wide , with a minimum 5/32 inch wide offset.
2.3.8.1.4 Coordination
Provide electric strikes and actuators of a size, weight and profile compatible with each specified door frame. Field verify installation clearances prior to procurement.
SECTION 08 71 00 Page 7
2.3.8.1.5 Mounting Method
Provide electric strikes and actuators suitable for use with single and double doors, with mortise or rim type hardware specified, and for right or left hand mounting as specified. In double door installations, locate the lock in the active leaf and monitor the fixed leaf.
2.3.8.2 Electrified Mortise Locks
Provide in accordance with ANSI/BHMA A156.25 , Grade 1. Provide electrified mortise locks that remain secure during power failure.
Provide facility interface devices that use dc power to energize solenoids. Provide solenoids, resisters, and signal switches in accordance with paragraph ELECTRIC STRIKES AND FRAME MOUNTED ACTUATORS.
2.3.8.2.1 Power Transfer Hinges
Provide power transfer hinges with each electrified lock that route power and monitoring signals from the lockset to the door frame. Coordinate power transfer hinges with door frames.
2.3.8.3 Card Readers and Keypad Access Control Hardware
***Amendment 0003 Provide in accordance with ANSI/BHMA A156.5 and ANSI/BHMA A156.25 , Grade 1 components. Provide devices that are tamper alarmed, tamper and vandal resistant, solid state, and do not contain electronics which could compromise the access control subsystem should the subsystem be attacked. Provide surface, semi-flush, pedestal, or weatherproof mountable devices as specified for each individual location.
Each device to contain a visual display, either mounted on the face, or on an integral part of the device, to indicate access or exit request processing, request approval, and request denial. Provide in accordance with Base Security Requirements type card readers capable of reading magnetic stripe or high coercivity magnetic stripe or Wiegand or Hollerith or proximity or Transmissive Infrared or Keypad or Smart Card or Biometric type access control cards. Provide keypads that contain an integral 12-digit tactile keyboard with digits arranged in numerical order.
Provide keypads that are a standalone device or integrated into the card reader. Coordinate access control hardware with corresponding devices and systems. Amendment 0003*****
2.3.8.4 Power Operated Pedestrian Door Hardware
Provide in accordance with ANSI/BHMA A156.10 , Grade 1.
2.3.8.5 Release Devices
In accordance with ANSI/BHMA A156.15 , Grade 1.
2.3.8.5.1 Closer Holders
Provide floor or door or header mounted closer holder devices connected by integral releasing to fire and smoke detecting devices.
2.3.8.6 Power Assist and Low Energy Power Operated Doors
Provide in accordance with ANSI/BHMA A156.19 , Grade 1.
SECTION 08 71 00 Page 8
2.3.8.7 Electromagnetic Locks
Provide in accordance with ANSI/BHMA A156.23 , Grade 1. Provide electromagnetic locks that do not contain any moving parts and depend solely upon electromagnetism to secure a portal by generating at least 1200 pounds of holding force. The lock must interface with the local processors without external, internal or functional alteration of the local processor. The electromagnetic lock must incorporate an end of line resistor to facilitate line supervision by the system. Provide metal-oxide resistors (MOVs) to protect controllers from reverse current surges, if not incorporated into the electromagnetic lock or local controller.
2.3.8.7.1 Armature
Provide electromagnetic locks with internal circuitry to eliminate residual magnetism and inductive kickback. Provide atuating armature that operates on 12 or 24 Volts dc and cannot dissipate more than 12 Watts.
Holding current must be less than 500 milliamperes. Actuating armature must take less than 300 milliseconds to change the status of the lock from fully secure to fully open or fully open to fully secure.
2.3.8.7.2 Tamper Resistance
Provide lock mechanism encased in hardened guard barriers to deter forced entry.
2.3.8.7.3 Mounting Method
Provide electromagnetic lock suitable for use with single and double door with mortise or rim type hardware and compatible with right or left hand mounting.
2.3.8.8 Delayed Egress Locking System
Provide in accordance with ANSI/BHMA A156.24 , Grade 1.
2.3.9 Keying System
Provide a grand master keying system as an extension of the existing base keying system. Existing Base locks were manufactured by Schlage and have interchangeable cores.Provide key cabinet as specified.
2.3.10 Lock Trim
Provide cast, forged, or heavy wrought construction and commercial plain design for lock trim.
2.3.10.1 Lever Handles
Provide lever handles where indicated in the Hardware Schedule. Provide in accordance with ANSI/BHMA A156.3 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.
SECTION 08 71 00 Page 9
2.3.11 Keys
Furnish one file key, one duplicate key, and one working key for each key change and for each master keying system. Furnish one additional working key for each lock of each keyed-alike group. Furnish a quantity of key blanks equal to 20 percent of the total number of file keys. Stamp each key with appropriate key control symbol and "U.S. property - do not duplicate." Do not place room number on keys.
2.3.12 Door Bolts
Provide in accordance with ANSI/BHMA A156.16 . Provide dustproof strikes for bottom bolts, except at doors having metal thresholds. Provide automatic latching flush bolts in accordance with ANSI/BHMA A156.3 , Type 25.
2.3.13 Closers
Provide in accordance with ANSI/BHMA A156.4 , Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, full size covers, except at storefront mounting, and other features necessary for the particular application. Size closers in accordance with manufacturer's printed recommendations, or provide multi-size closers, Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.
Use stainless steel inside bracketed or door mounted closers on exterior doors. Non-ferrous closers, such as aluminum or cast bronze, are permissible where door utilization is minimal. On interior doors use closers of 302 or 304 stainless steel or non-ferrous materials. On surface-mounted closers use or apply rust inhibiting finish on all ferrous parts. Also apply this finish on concealed closers.
2.3.13.1 Identification Marking
Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation in locations that will be visible after installation.
2.3.14 Overhead Holders
Provide in accordance with ANSI/BHMA A156.8 .
2.3.15 Door Protection Plates
Provide in accordance with ANSI/BHMA A156.6 .
2.3.15.1 Sizes of Mop and Kick Plates
2 inch less than door width for single doors; 1 inch less than door width for pairs of doors. Provide 10 inch kick plates for flush doors .
Provide a minimum 36 inch armor plates for flush doors and completely cover lower panels of panel doors, except 16 inch high armor plates on fire doors. Provide 4 inch mop plates.
2.3.15.2 Edge Guards
Stainless steel, of same height as armor plates. Apply to hinge stile , lock stile or meeting stiles.
SECTION 08 71 00 Page 10
2.3.16 Door Stops and Silencers
Provide in accordance with ANSI/BHMA A156.16 . Silencers Type L03011.
Provide three silencers for each single door, two for each pair.
2.3.17 Padlocks
Provide in accordance with ASTM F883.
2.3.18 Thresholds
Provide in accordance with ANSI/BHMA A156.21 . Use J35100, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise. Thresholds at exterior doors must be Florida Building Code compliant.
2.3.19 Weatherstripping Gasketing
Provide in accordance with ANSI/BHMA A156.22 . Provide the type and function designation where specified in paragraph HARDWARE SCHEDULE.
Provide a set to include head and jamb seals, sweep strips, and, for pairs of doors, astragals. Air leakage of weatherstripped doors not to exceed
0.5 cubic feet per minute of air per square foot of door area when tested in accordance with ASTM E283. Provide weatherstripping with one of the following:
2.3.19.1 Extruded Aluminum Retainers
Extruded aluminum retainers not less than 0.050 inch wall thickness with vinyl, neoprene, silicone rubber, or polyurethane inserts. Provide bronze anodized aluminum.
2.3.19.2 Interlocking Type
Zinc or bronze not less than 0.018 inch thick.
2.3.19.3 Spring Tension Type
Spring bronze or stainless steel not less than 0.008 inch thick.
2.3.20 Soundproofing Gasketing
Provide in accordance with ANSI/BHMA A156.22 . Provide adjustable doorstops at heads,jambs and automatic door bottoms in accordance with the hardware set, of extruded aluminum, clear (natural) anodized, surface applied, with vinyl fin seals between plunger and housing. Provide doorstops with solid neoprene tube, silicone rubber, or closed cell sponge gasket. Provide door bottoms with adjustable operating rod and silicone rubber or closed cell sponge neoprene gasket. Provide doorstops that are mitered at corners. Provide type and function designation where specified in paragraph HARDWARE SETS.
2.3.21 Rain Drips
Provide in accordance with ANSI/BHMA A156.22 . Provide extruded aluminum rain drips, not less than 0.08 inch thick, bronze anodized finish.
Provide the manufacturer's full range of color choices to the Contracting Officer for color selection. Provide rain drips with a 4 inch overlap on
SECTION 08 71 00 Page 11 each side of each exterior door that is not protected by an awning, roof, eave or other horizontal projection. Set drips in sealant and fasten with stainless steel screws.
2.3.21.1 Door Rain Drips
Approximately 1-1/2 inch high by 5/8 inch projection. Align bottom with bottom edge of door.
2.3.21.2 Overhead Rain Drips
Approximately 1-1/2 inch high by 2-1/2 inch projection. Align bottom with door frame rabbet.
2.3.22 Auxiliary Hardware (Other than locks)
Provide in accordance with ANSI/BHMA A156.16 , Grade 1.
2.3.23 Special Tools
Provide special tools, such as spanner and socket wrenches and dogging keys, as required to service and adjust hardware items.
2.4 FASTENERS
Provide fasteners of type, quality, size, and quantity appropriate to the specific application. Fastener finish to match hardware. Provide stainless steel or nonferrous metal fasteners in locations exposed to weather. Verify metals in contact with one another are compatible and will avoid galvanic corrosion when exposed to weather.
2.5 FINISHES
Provide in accordance with ANSI/BHMA A156.18 . Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide items not manufactured in stainless steel in BHMA 626 finish (satin chromium plated) over brass or bronze, except aluminum paint finish for surface door closers, and except BHMA 652 finish (satin chromium plated) for steel hinges. Provide hinges for exterior doors in stainless steel with BHMA 630 finish or chromium plated brass or bronze with BHMA 626 finish. Furnish exit devices in BHMA 626 finish in lieu of BHMA 630 finish except where BHMA 630 is specified under paragraph HARDWARE SETS.
Match exposed parts of concealed closers to lock and door trim. Match hardware finish for aluminum doors to the doors.
2.6 KEY CABINET AND CONTROL SYSTEM
Provide in accordance with ANSI/BHMA A156.5 . Type required to yield a capacity (number of hooks) 50 percent greater than the number of key changes used for door locks.
PART 3 EXECUTION
3.1 INSTALLATION
Provide hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.
SECTION 08 71 00 Page 12
Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.
3.1.1 Weatherstripping Installation
Provide full contact, weathertight seals that allow operation of doors without binding the weatherstripping.
3.1.1.1 Stop Applied Weatherstripping
Fasten in place with color matched sheet metal screws not more than 9 inch on center after doors and frames have been finish painted.
3.1.1.2 Interlocking Type Weatherstripping
Provide interlocking, self adjusting type on heads and jambs and flexible hook type at sills. Nail weatherstripping to door 1 inch on center and to heads and jambs at 4 inch on center.
3.1.1.3 Spring Tension Type Weatherstripping
Provide spring tension type on heads and jambs. Provide bronze nails with bronze. Provide stainless steel nails with stainless steel. Space nails not more than 1-1/2 inch on center.
3.1.2 Lightproofing and Soundproofing Installation
Provide as specified for stop applied weatherstripping.
3.1.3 Threshold Installation
Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, steel screws in expansion sleeves. For aluminum thresholds placed on top of concrete surfaces, coat the underside surfaces that are in contact with the concrete with fluid applied waterproofing as a separation measure prior to placement.
3.2 FIRE DOORS AND EXIT DOORS
Provide hardware in accordance with NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, and NFPA 252 for fire tests of door assemblies.
3.3 HARDWARE LOCATIONS
Provide in accordance with SDI/DOOR A250.8 , unless indicated or specified otherwise.
a. Kick and Armor Plates: Push side of single-acting doors. Both sides of double-acting doors.
b. Mop Plates: Bottom flush with bottom of door.
3.4 KEY CABINET AND CONTROL SYSTEM
Locate where directed. Tag one set of file keys and one set of duplicate keys. Place other keys in appropriately marked envelopes, or tag each
SECTION 08 71 00 Page 13 key. Provide complete instructions for setup and use of key control system. On tags and envelopes, indicate door and room numbers or master or grand master key.
3.5 FIELD QUALITY CONTROL
After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, errors in cutting and fitting and damage to adjoining work.
3.6 HARDWARE SETS
The hardware sets represent the design intent. They are a guideline only and should not be considered a detailed hardware schedule. Discrepancies, conflicting hardware and missing items should be brought to the attention of the Contracting Officer with corrections made prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application and functionality.
a. Quantities listed are for each pair of doors, or for each single door.
b. The supplier is responsible for handing and sizing all products.
c. Where multiple options for a piece of hardware are given in a single line item, the supplier shall provide the appropriate application for the opening.
d. Basis of design hardware manufacturers are provided to establish level of quality. Products from other manufacturers having equal or greater quality, and meeting the specified performance requirements, may be provided.
Manufacturer's Abbreviations:
1. MK - McKinney
2. MR - Markar
3. PE - Pemko
4. RF - Rixson
5. SU - Securitron
6. RO - Rockwood
7. YA - ASSA ABLOY ACCENTRA
8. SA - SARGENT
9. AD - Adams Rite
10. MC - Medeco
11. HS - HES
12. NO - Norton
SECTION 08 71 00 Page 14
SECTION 08 71 00 Page 15
Hardware Sets
Set: 1.0
Exterior Glazed Double Aluminum Entrance Door with Card Reader / Keypad
Doors: AV100a, AV100b, BV100a, BV100b
2 Continuous Hinge (A31031G) _FM (height) HD1 PT PE
2 Electric Power Transfer EL-CEPT
2 Exit Device (Type 1, 03, E04) 7100F B MELR Offset, SFIC Temp Core
YA
2 Interchangeable Core (E09241) 33600006N MC
Mortise Cylinder Housing
(E09251)
K660 YA
2 Surface Closer (C02021-PT4G) 3531 691 YA
2 Sweep (R3A434) 293100_NB PE
1 Threshold (J36100) 2009_PK PE
2 Frame Harness QC-C1500P MK
2 Door Harness QC-C___ LAR MK
1 Card Reader
BY SECURITY
INTEGRATOR
1 Power Supply* AQDxx - TAA (TO SUIT) SU
1 Mag Position Switch
Notes:
All hardware by assembly manufacturer. Blast / Hurricane compliant w/ flush mount Rim Panic devices.
Hardware set provided is for intent only. Actual products as required for as tested assembly certification.
•Offset Pull Handle, integrated with aluminum stile.
•Doors normally locked and closed.
•Presenting valid credential retracts latch and allows for entry by manual pull/lever or by energized actuator.
•Entry by manual key
•Egress by push pad or by actuator at all times.
•Free egress permitted at all times.
•Perimeter / meeting stile gasketing by Alum Door / Frame Manufacturer.
BV100a and BV100b, OPERATION: - Exterior bollard-mounted card reader temporarily retracts the latchbolt on the active leaf and enables the exterior bollard-mounted push pad. Bollard mounted push pads retract the latchbolts and activate the door operators upon actuation. Electronic locking device is fail-secure, with an interior request-to-exit (RX) switch located in the door rail. The active leaf is equipped with an exterior key override. The interior rail always permits free egress.
SECTION 08 71 00 Page 16
Set: 2.0
Interior Glazed Double Aluminum Entry Door
Doors: AV100c, AV100d, BV100c, BV100d
2 Continuous Hinge (A31031G) _FM (height) HD1 PE
2 Exit Device (Type 03, E04) 7100F B MELR Offset, SFIC Temp Core
YA
2 Interchangeable Core (E09241) 33600006N MC
Mortise Cylinder Housing
(E09251)
K660 YA
2 Overhead Stop (C01541) 6ADJ-X36 612 RF
2 Surface Closer (C02011 / C02021) R / PR3501 (TO SUIT) 691 YA
2 Sweep (R3A434) 293100_NB PE
Notes: All hardware by assembly manufacturer. Blast / Hurricane compliant w/ flush mount Rim Panic devices. Hardware set provided is for intent only. Actual products as required for as tested assembly certification.
•Offset Pull Handle, integrated with aluminum stile.
•Doors normally locked and closed.
•Presenting valid credential retracts latch and allows for entry by manual pull/lever or by energized actuator.
•Entry by manual key
•Egress by push pad or by actuator at all times.
•Free egress permitted at all times.
Perimeter / meeting stile gasketing by Alum Door / Frame Manufacturer.
Set: 3.0
REVISED BY AMENDMENT 0007
Exterior Double HM Entry Door with Card Reader / Keypad
Doors: KV100a
1 Continuous Hinge (A51331B) FM300 x EL-CEPTx32D
Cut to Length
630 MR
1 Continuous Hinge (A51031B) FM300 xxx Cut to Length 630 MR
2 Exit Device (Type 03, E04) HC8600 CVR, ELR, Temp
Core x 630
630 SA
1 Astragal (R3E734) 29310_S PE
2 Interchangeable Core (E09241) 33600006N MC
Mortise Cylinder Housing
(E09251)
K660 YA
2 Surface Closer (Part of assembly) 281 CPS EN SA
4 Gasketing (R0E154) S771 (head and sill for PE
SECTION 08 71 00 Page 17
Flood Control)
1 Gasketing (R3G165) 312CR TKSP PE
1 Rain Guard (R0Y976) 346C PE
4 Sweep (R3B434) 315CN (head and sill for
Flood Control)
PE
1 Threshold (part of Flood Control) 766A PE
1 Frame Harness QC-C1500P MK
1 Door Harness QC-C___ LAR MK
1 Card Reader
2 Mag Position Switch
INTEGRATOR
SU
1 Power Supply* AQDxx - TAA (TO SUIT) SU
Adhesive (R0C05_ Flood Control) P385 PE
Adhesive (R0C05_ Flood Control) P381 PE
Adhesive (R0C05_ Flood Control) P261 PE
Adhesive (R0C05_ Flood Control) P266 PE
2 Kick Plate K1050 8" US32D RO
Notes: Install all weather stripping per tech data for flood control assembly.
•Door normally closed and locked
•Unlocking of door by mechanical key alerts head end system of entry w/ out audit trail.
•Presenting proper credential unlocks outside lever/retracts latch and shunts DPS for authorized entry.
•RX tied to inside push pad shunts DPS for set period of time.
•DPS alerts if doors are held open longer than programmed time.
•Device is Fail Secure and remains locked upon loss of power.
•Free egress at all times.
Flood control based on Curries (Water infiltration tech data)
Set: 4.0
Interior Double HM Entry Door
Doors: KV100b
6 Hinge (A8111) T4A3786 US26D MK
2 Exit Device (Type 03, E04) 8600 CVR, ELR, Temp
Core
630 SA
1 Astragal (R3E734) 29310_S PE
2 Interchangeable Core (E09241) 33600006N MC
Mortise Cylinder Housing
(E09251)
K660 YA
SECTION 08 71 00 Page 18
2 Overhead Stop (C01541) 6ADJ-X36 612 RF
2 Surface Closer (C02011 / C02021) R / PR3501 (TO SUIT) 691 YA
2 Kick Plate (J102) K1050 10" CSK US32D RO
1 Adhesive Gasketing (R0Y154) S88 PE
Note: Kick plate at in swinging doors only.
Set: 5.0
Exterior Single HM Exit Only Door
Doors: AC100a, AST101a, BG108
Cut to Length
630 MR
1 Exit Device (Type 01, E01) HC8800 Exit Device, Exit
Only, Less Trim
630 SA
1 Interchangeable Core (E09241) 33600006N MC
1 Surface Closer (Part of assembly) 281 CPS EN SA
1 Gasketing (R0E154) S771 (head and sill for
Flood Control)
PE
1 Gasketing (R0E154) S44 PE
1 Gasketing (R3G165) 312CR TKSP PE
1 Rain Guard (R0Y976) 346C PE
2 Sweep (R3B434) 315CN (head and sill for
Flood Control)
PE
1 Threshold (J36100) 2008APK (Less PK) PE
1 Mag Position Switch
BY SECURITY
INTEGRATOR
SU
1 Power Supply* AQDxx - TAA (TO SUIT) SU
Adhesive (R0C05_ Flood Control) P385 PE
Adhesive (R0C05_ Flood Control) P381 PE
• Exterior side of door has no operable door hardware.
• Install all weather stripping per tech data for flood control assembly.
• Door normally closed and locked.
• DPS alerts when the door is open.
• Free egress at all times.
SECTION 08 71 00 Page 19
Set: 6.0
Exterior Single HM Door with Card Reader / Keypad
Doors: KST100
Cut to Length
630 MR
1 Exit Device (Type 01, E01)
HC8800, MELR, ET,
Temp Core
630 SA
1 Interchangeable Core (E09241) 33600006N MC
1 Surface Closer (Part of assembly) 281 CPS EN SA
1 Gasketing (R0E154) S771 (head and sill for
Flood Control)
PE
1 Gasketing (R0E154) S44 PE
1 Gasketing (R3G165) 312CR TKSP PE
1 Rain Guard (R0Y976) 346C PE
2 Sweep (R3B434) 315CN (head and sill for
Flood Control)
PE
1 Threshold (J36100) 2008APK (Less PK) PE
1 Card Reader
INTEGRATOR
SU
1 Power Supply* AQDxx - TAA (TO SUIT) SU
Adhesive (R0C05_ Flood Control) P385 PE
Adhesive (R0C05_ Flood Control) P381 PE
• Install all weather stripping per tech data for flood control assembly.
• Door normally closed and locked.
• DPS alerts when the door is open.
Set: 7.0
Exterior Double HM Exit Only Door
Doors: DC102, FC104, JC103, KC101
Cut to Length
630 MR
1 Continuous Hinge (A51031B) FM300 xxx Cut to Length 630 MR
2 Exit Device (Type 01, E01) HC8600 CVR, Less Trim 630 SA
SECTION 08 71 00 Page 20
1 Astragal (R3E734) 29310_S PE
2 Interchangeable Core (E09241) 33600006N MC
Mortise Cylinder Housing
(E09251)
K660 YA
2 Surface Closer (Part of assembly) 281 CPS EN SA
4 Gasketing (R0E154) S771 (head and sill for
Flood Control)
PE
1 Gasketing (R3G165) 312CR TKSP PE
1 Rain Guard (R0Y976) 346C PE
4 Sweep (R3B434) 315CN (head and sill for
Flood Control)
PE
1 Threshold (J36100) 2008APK (Less PK) PE
1 Threshold (part of Flood Control) 766A PE
2 Mag Position Switch
BY SECURITY
INTEGRATOR
SU
1 Power Supply* AQDxx - TAA (TO SUIT) SU
Adhesive (R0C05_ Flood Control) P385 PE
Adhesive (R0C05_ Flood Control) P381 PE
Adhesive (R0C05_ Flood Control) P261 PE
Adhesive (R0C05_ Flood Control) P266 PE
Notes:
• Exterior side of door has no operable door hardware.
• Install all weather stripping per tech data for flood control assembly.
• Door normally closed and locked.
• DPS alerts when the door is open.
• Kick plate to be provided for inside surface of the doors
Set: 8.0
Exterior Double HM Door with Card Reader / Keypad
Doors: B101b, CC100a, EC100a, FC100b, J100, JC100a
Cut to Length
630 MR
1 Continuous Hinge (A51031B) FM300 xxx Cut to Length 630 MR
2 Exit Device (Type 03, E04)
9300/F9300 YR23
HC8600 CVR, ELR, Temp
Core
630 SA
2 Astragal (R3E734) 29310_S PE
2 Interchangeable Core (E09241) 33600006N MC
Mortise Cylinder Housing
(E09251)
K660 YA
SECTION 08 71 00 Page 21
2 Surface Closer (Part of assembly) 281 CPS EN SA
4 Gasketing (R0E154) S771 (head and sill for
Flood Control)
PE
1 Gasketing (R3G165) 312CR TKSP PE
1 Rain Guard (R0Y976) 346C PE
4 Sweep (R3B434) 315CN (head and sill for
Flood Control)
PE
1 Threshold (J36100) 2008APK (Less PK) PE
1 Threshold (part of Flood Control) 766A PE
1 Frame Harness QC-C1500P MK
1 Door Harness QC-C___ LAR MK
1 Card Reader
2 Mag Position Switch
INTEGRATOR
SU
1 Power Supply* AQDxx - TAA (TO SUIT) SU
Adhesive (R0C05_ Flood Control) P385 PE
Adhesive (R0C05_ Flood Control) P381 PE
Adhesive (R0C05_ Flood Control) P261 PE
Adhesive (R0C05_ Flood Control) P266 PE
2 Kick Plate (J102) K1050 10" CSK US32D RO
•Unlocking of door by mechanical key alerts head end system of entry w/ out audit trail.
•Presenting proper credential unlocks outside lever/retracts latch and shunts DPS for authorized entry.
•RX tied to inside push pad shunts DPS for set period of time.
•DPS alerts if door is held open longer than programmed time.
•Device is Fail Secure and remains locked upon loss of power.
•Kick plate to be provided for inside surface of the doors.
Set: 9.0
Exterior Keyed Double HM Door
Doors: A137, A138, B110a, K103, K104
Cut to Length
630 MR
1 Continuous Hinge (A51031B) FM300 xxx Cut to Length 630 MR
2 Exit Device (Type 03, E04) HC8600 CVR, ELR, Temp
Core
630 SA
1 Astragal (R3E734) 29310_S 630 PE
SECTION 08 71 00 Page 22
2 Interchangeable Core (E09241) 33600006N MC
Mortise Cylinder Housing
(E09251)
K660 YA
2 Surface Closer (Part of assembly) 281 CPS EN SA
4 Gasketing (R0E154) S771 (head and sill for
Flood Control)
PE
1 Gasketing (R3G165) 312CR TKSP PE
1 Rain Guard (R0Y976) 346C PE
4 Sweep (R3B434) 315CN (head and sill for
Flood Control)
PE
1 Threshold (part of Flood Control) 766A PE
2 Mag Position Switch
BY SECURITY
INTEGRATOR
SU
1 Power Supply* AQDxx - TAA (TO SUIT) SU
Adhesive (R0C05_ Flood Control) P385 PE
Adhesive (R0C05_ Flood Control) P381 PE
Adhesive (R0C05_ Flood Control) P261 PE
Adhesive (R0C05_ Flood Control) P266 PE
2 Armor Plate 8400 34" US32D
2 Overhead Holder *9-X26 630 SA
• Door normally closed and locked
• Unlocking of door by mechanical key alerts head end system of entry w/ out audit trail.
• Presenting proper credential unlocks outside lever/retracts latch and shunts DPS for authorized entry.
• RX tied to inside push pad shunts DPS for set period of time.
• DPS alerts if door is held open longer than programmed time.
• Device is Fail Secure and remains locked upon loss of power.
Set: 10.0
Exterior Keyed Single HM Door
Doors: B109a, BST100, J103a, J103b
Cut to Length
630 MR
1 Exit Device (Type 01, E01) HC8870 Rim Exit Device, Keyed Trim, Temp Core
630 SA
1 Interchangeable Core (E09241) 33600006N MC
SECTION 08 71 00 Page 23
1 Surface Closer (Part of assembly) 281 CPS EN SA
1 Gasketing (R0E154) S771 (head and sill for
Flood Control)
PE
1 Gasketing (R3G165) 312CR TKSP PE
1 Rain Guard (R0Y976) 346C PE
2 Sweep (R3B434) 315CN (head and sill for
Flood Control)
PE
1 Threshold (J36100) 2008APK (Less PK) PE
1 Mag Position Switch
BY SECURITY
INTEGRATOR
SU
1 Power Supply* AQDxx - TAA (TO SUIT) SU
22 Adhesive (R0C05_ Flood Control) P385 PE
1 Adhesive (R0C05_ Flood Control) P381 PE
1 Armor Plate 8400 34" US32D
1 Overhead Holder *9-X26 630 SA
Install all weather stripping per tech data for flood control assembly.
•Presenting proper credential unlocks outside lever/retracts latch and shunts DPS for authorized entry.
•RX tied to inside push pad shunts DPS for set period of time.
•DPS alerts if doors are held open longer than programmed time.
Set: 11.0
Interior Keyed Single HM Door
Doors: B105, E101, F107, K106
4 Hinge (A8111) T4A3786 US26D MK
1 Exit Device (Type 1, 03) 7100 AU627 Temp Core 630 YA
1 Interchangeable Core (E09241) 33600006N MC
1 Surface Closer (C02011 / C02021) R/PR3501 (TO SUIT) 689 YA
1 Kick Plate (J102) K1050 10" CSK US32D RO
1 Overhead Holder-C02511 *9-X26 630 SA
SECTION 08 71 00 Page 24
Set: 12.0
Interior Keyed Double HM Door
Doors: G101
1 Exit Device (Type 2, 03) 7170 LBR AU627F Temp
Core
630 YA
1 Exit Device (Type 2, 01) 7170 LBR EO 630 YA
2 Surface Closer (C02021-PT4G) 3531 689 YA
2 Astragal (R3E734) 29310_S PE
2 Overhead Holder-C02511 *9-X26 630 SA
2 Kick Plate (J102) K1050 10" CSK US32D RO
Set: 13.0
Interior Keyed (Smoke-Rated) Single HM Door
Doors: A207
3 Hinge (A8111) T4A3786 US26D MK
1 Exit Device (Type 1, 03) 7100F AU627F Temp Core 630 YA
1 Interchangeable Core (E09241) 33600006N MC
1 Surface Closer (C02021-PT4G) 3531 689 YA
1 Kick Plate (J102) K1050 10" CSK US32D RO
1 Adhesive Gasketing (R0Y154) S88 PE
1 Overhead Holder-C02511 *9-X26 630 SA
Perimeter Gasket – R3D166 X
LAR
S8DD PE
1 Sweep – R3B434 315CN PE
Set: 14.0
Interior Keyed (Smoke-Rated) Single HM Door with Card Reader / Keypad
Doors: B109b, B110b
1 Electric Power Transfer* EL-CEPT 630 SU
1 Fail Secure Lock (E01, E06) AUR 8891FL Temp Core
REX
626 YA
1 Surface Closer (C02011 / C02021) R/PR3501 (TO SUIT) 689 YA
SECTION 08 71 00 Page 25
1 Kick Plate (J102) K1050 10" CSK US32D RO
1 Frame Harness QC-C1500P MK
1 Door Harness QC-C___ LAR MK
1 Position Switch (E08) DPS-M-BK SU
1 Power Supply* AQDxx - TAA (TO SUIT) SU
1 Card Reader
1 Kick Plate
Perimeter Gasket – R3D166 X
LAR
S8DD PE
1 Sweep – R3B434 315CN PE
*Waiver may be required to comply with Trade Agreement Act.
• Card reader by security integrator.
• Electronic Operation: Valid card unlocks outside lever or key retracts latch bolt. Request to exit shows authorized egress. Free egress at all times. In case of power loss or fire alarm, door remains locked and latched.
Set: 15.0
Interior Single HM Door with Card Reader / Keypad
Doors: A100, A206, B100, B202, E102, F104, H102, K105, A139
1 Exit Device (Type 1, 03) 7100F AU627F Temp Core 630 YA
1 Electric Power Transfer* EL-CEPT 630 SU
1 Fail Secure Lock (E01, E06) AUR 8891FL Temp Core
REX
626 YA
1 Interchangeable Core (E09241) 33600006N MC
1 Surface Closer (C02011 / C02021) R/PR3501 (TO SUIT) 689 YA
3 Silencer (L03011) 608 RO
1 Frame Harness QC-C1500P MK
1 Door Harness QC-C___ LAR MK
1 Position Switch (E08) DPS-M-BK SU
1 Power Supply* AQDxx - TAA (TO SUIT) SU
1 Card Reader
SECTION 08 71 00 Page 26
1 Kick Plate
• Card reader by security integrator.
• Electronic Operation: Valid card unlocks outside lever or key retracts latch bolt. Request to exit shows authorized egress. Free egress at all times. In case of power loss or fire alarm, door remains locked and latched.
• Provide crash bars on all telecom room doors.
Set: 16.0
Interior Single HM (Smoke-Rated) Door with Card Reader / Keypad
Doors: A107, B111
1 Electric Power Transfer* EL-CEPT 630 SU
1 Exit Device (Type 1, 03) 7100F AU627F Temp Core 630 YA
1 Fail Secure Lock (E01, E06) AUR 8891FL Temp Core
REX
626 YA
1 Interchangeable Core (E09241) 33600006N MC
1 Surface Closer (C02011 / C02021) R/PR3501 (TO SUIT) 689 YA
1 Kick Plate (J102) K1050 10" CSK US32D RO
Door closer with a built-in stop arm control, instead of door stop
1 Adhesive Gasketing (R0Y154) S88 PE
1 Frame Harness QC-C1500P MK
1 Door Harness QC-C___ LAR MK
1 Power Supply* AQDxx - TAA (TO SUIT) SU
1 Card Reader
• Card reader by security integrator.
• Electronic Operation: Valid card unlocks outside lever or key retracts latch bolt. Request to exit shows authorized egress. Free egress at all times. In case of power loss or fire alarm, door remains locked and latched.
• Provide crash bars on all telecom room doors.
• For this smoke-rated door, specific gasketing and door sweeps are required to maintain the integrity of the smoke barrier
SECTION 08 71 00 Page 27
Set: 17.0
Interior Single HM Door (STC-Rated)
Doors: AG102, AG103, AG202, AG203, BG101, BG103, EG100, EG101, KG106, KG107
1 Push Pull (J406) 110x73C/73CL US32D RO
1 Surface Closer (C02011 / C02021) R/PR3501 (TO SUIT) 689 YA
Door closer with a built-in stop arm control, instead of door stop
1 Kick Plate (J102) K1050 10" CSK US32D RO
1 Mop Plate (J103) K1050 6" CSK US32D RO
1 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO
Pull Plate – J401, ¾” Dia. 8” CTC, 4” x 16” Plate BF 111x70c US32D RO
3 Silencer (L03011) 608 RO
• Mop plate at in swinging doors only.
• Perimeter gasket including sill provided by STC manufacturer as required to support STC 35 rating.
Set: 18.0
Interior Keyed Single HM Door
Doors: A230, AG104, AG204, BG105, BG106, BG109, EG102, EG103, KG100, KG108, KG109
3 Hinge (A8112) TA2714 US26D MK
1 Storeroom Lock (F07) AUR 8805FL Temp Core 626 YA
1 Interchangeable Core (E09241) 33600006N MC
1 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO
3 Silencer (L03011) 608 RO
Kick Plate (J102) (inside of the door)
K1050 10" CSK US32D RO
1 Armor Plate (outside of the door) 8400 34" US32D
Set: 19.0
NOT USED
Set: 20.0
Interior Single WDSC Door (STC 35)
Doors: A101a, A101b, A117, A118, A200a, A200b, A208a, A208b, A220, A224a, A224b, AG201, B104, BG107, F105, F106, K101, K102, SECTION 08 71 00 Page 28
1 Office Lock (F04) AUR 8807FL Temp Core 626 YA
1 Interchangeable Core (E09241) 33600006N MC
1 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO
3 Silencer (L03011) 608 RO
Notes:
Sound transmission control gasketing (by the sound door manufacturer)
Perimeter gasket including sill provided by STC manufacturer as required to support STC 35 rating
Set: 21.0
Interior Single WDSC Door (Secure + STC 35) with Card Reader / Keypad
Doors: A114a, A114b, A130a, A130b
Exit Device
(Type 1, 03)
7100F AU627F Temp
Core
630 YA
Electric Power
Transfer*
EL-CEPT 630 SU
Fail Secure
Lock (E01, E06)
AUR 8891FL Temp
Core REX
626 YA
Interchangeable
Core (E09241)
33600006N MC
Surface Closer
(C02011 /
C02021)
R/PR3501 (TO SUIT) 689 YA
Door closer with a built-in stop arm control, instead of door stop
Adhesive
Gasketing
(R0Y154)
S88 PE
1 Frame Harness QC-C1500P MK
1 Door Harness QC-C___ LAR MK
1 Card Reader
Position Switch
(E08)
DPS-M-BK SU
1 Power Supply* AQDxx - TAA (TO
SUIT)
SU
• Card reader by security integrator.
SECTION 08 71 00 Page 29
• Electronic Operation: Valid card unlocks outside lever or key retracts latch bolt. Request to exit shows authorized egress. Free egress at all times. In case of power loss or fire alarm, door remains locked and latched.
Perimeter gasket including sill provided by STC manufacturer as required to support STC 35 rating
Crash bars to be provided **higher-end recommended at these four (4) locations
Set: 22.0
Interior Double WDSC Door (Secure) with Card Reader / Keypad
Doors: AC100b
2 Electric Power Transfer* EL-CEPT 630 SU
2 Exit Device (Type 1, 03, E04) 7100F B MELR Offset, SFIC Temp Core
YA
2 Interchangeable Core (E09241) 33600006N MC
1 Removable Mullion (Type 22)
KRM200F - DOOR
HEIGHT
600 YA
2 Surface Closer (C02011 / C02021) R/PR3501 (TO SUIT) 689 YA
2 Astragal (R3E734) 29310_S PE
1 Adhesive Gasketing (R0Y154) S88 PE
2 Frame Harness QC-C1500P MK
2 Door Harness QC-C___ LAR MK
2 Position Switch (E08) DPS-M-BK SU
1 Card Reader
Set: 23.0
Interior Single HM Door (Fire-Rated) with Card Reader / Keypad
Doors: AST100, BST200, B201, KST200
Exit Device (Type
1, 14, UL RIM
EXIT)
7100F AU628F 630 YA
Surface Closer
(C02011 /
C02021)
R/PR3501 (TO SUIT) 689 YA
1 Kick Plate (J102) K1050 10" CSK US32D RO
1 Adhesive S88 PE
SECTION 08 71 00 Page 30
Gasketing
(R0Y154)
Overhead Holder-
C02511
*9-X26 630 SA
Surface Plate
Door Sweep Pemko 315_N
1 Sweep (R3A434) 293100_NB PE
Threshold
(J36100)
2009_PK PE
Set: 24.0
Interior Single HM Door (Fire-Rated + Secure) with Card Reader / Keypad
Doors: AST101b, AST201, AST200
Electric Power
Transfer*
EL-CEPT 630 SU
Fail Secure Lock
(E01, E06)
AUR 8891FL Temp
Core REX
626 YA
Interchangeable
Core (E09241)
33600006N MC
Surface Closer
(C02011 /
C02021)
R/PR3501 (TO SUIT) 689 YA
1 Kick Plate (J102) K1050 10" CSK US32D RO
Door closer with a built-in stop arm controls, instead of door stop
Adhesive
Gasketing
(R0Y154)
S88 PE
1 Frame Harness QC-C1500P MK
1 Door Harness QC-C___ LAR MK
Position Switch
(E08)
DPS-M-BK SU
1 Power Supply* AQDxx - TAA (TO
SUIT)
SU
1 Card Reader
Fire Rated Rim
Exit F9300 YR08 630 (ED-3) Dorma Door
1 Sweep (R3A434) 293100_NB PE
Threshold
SECTION 08 71 00 Page 31
• Card reader by security integrator.
• Electronic Operation: Valid card unlocks outside lever or key retracts latch bolt. Request to exit shows authorized egress. Free egress at all times. In case of power loss or fire alarm, door remains locked and latched.
Set: 25.0
Interior Single WDSC Door (Fire-Rated)
Doors: A113
4 Hinge (A8111) T4A3786 US26D MK
Storeroom Lock
(F07)
AUR 8805FL Temp
Core
626 YA
Interchangeable
Core (E09241)
33600006N MC
Surface Closer
(C02011 /
C02021)
R/PR3501 (TO SUIT) 689 YA
1 Kick Plate (J102) K1050 10" CSK US32D RO
Door closer with a built-in stop arm controls, instead of door stop
Adhesive
Gasketing
(R0Y154)
S88 PE
1 Sweep (R3A434) 293100_NB PE
Threshold
For this smoke-rated door, specific gasketing and door sweeps are required to maintain the integrity of the smoke barrier.
• Card reader by security integrator.
• Electronic Operation: Valid card unlocks outside lever or key retracts latch bolt. Request to exit shows authorized egress. Free egress at all times. In case of power loss or fire alarm, door remains locked and latched.
Set: 26.0
Exterior Single HM Door (Mechanical Yard)
Door: AS101
Cut to Length
630 MR
SECTION 08 71 00 Page 32
1 Exit Device (Type 01, E01) HC8870 Rim Exit Device, Keyed Trim, Temp Core
630 SA
1 Interchangeable Core (E09241) 33600006N MC
1 Surface Closer (Part of assembly) 281 CPS EN SA
1 Gasketing (R0E154) S771 (head and sill for
Flood Control)
PE
1 Gasketing (R3G165) 312CR TKSP PE
1 Rain Guard (R0Y976) 346C PE
2 Sweep (R3B434) 315CN (head and sill for
Flood Control)
PE
1 Threshold (J36100) 2008APK (Less PK) PE
1 Mag Position Switch
BY SECURITY
INTEGRATOR
SU
1 Power Supply* AQDxx - TAA (TO SUIT) SU
1 Armor Plate 8400 34" US32D
1 Overhead Holder *9-X26 630 SA
Install all weather stripping per tech data for flood control assembly.
•Presenting proper credential unlocks outside lever/retracts latch and shunts DPS for authorized entry.
•RX tied to inside push pad shunts DPS for set period of time.
•D…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .