Amendment 0006 Attachment.pdf
PDF 74 KB Posted
- Solicitation number
- N6945026R0005
About this file
This is an amendment (Amendment 0006) to a federal contract solicitation dated 03JUN2026 that modifies plan sheets and specification sections for a coating and surface preparation project.
The amendment removes and replaces ten specific plan sheets (A201, A401, A513, C202, C205, C206, C305, C405, C502, and C508) with updated versions. For Specification Section 09 67 23.16, Paragraph 1.3.5.5, the amendment modifies contractor certification requirements by removing references to specific SSPC certification types (SSPC QP 8 and SSPC QS 1) and replacing them with general certification requirements prior to contract award. The revised language clarifies that contractors performing surface preparation or coating application must maintain certification throughout project duration, with explicit language stating that requests for time extensions due to inactive certifications will not be considered. The amendment also adds a requirement that installation contractors must be certified by material manufacturers to install submitted coatings and sealants. Additionally, the amendment removes and replaces Specification Sections 07 19 00 and 07 42 13 with updated versions. The minimum qualifications for installation contractors remain unchanged, requiring completion of three or more jobs within the past two years on concrete surfaces exceeding 200,000 square feet total area, with supporting documentation of project locations, contacts, square footage, materials, equipment, and manufacturer validation of material quality.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
03JUN2026
Amendment 0006 Attachments
Remove the following plan sheets from the solicitation
A201, A401, A513, C202, C205, C206, C305, C405, C502, and C508
Replace with the following plan sheets
A201, A401, A513, C202, C205, C206, C305, C405, C502, and C508
Specification Section 09 67 23.16, Paragraph 1.3.5.5
Remove:
All Contractors that perform surface preparation or coating application must be certified to SSPC QP 8 and should also be SSPC QS 1 certified prior to Contract award and must remain certified while accomplishing any surface preparation or coating application.
The painting Contractors must remain so certified for the duration of the project. If a Contractor’s certification expires, the firm will not be allowed to perform any work until the certification is reissued. Notify the Contracting Officer of any change in Contractor certification status. Notify the Contracting Officer of all schedule and unannounced on-site audits from SSPC and furnish a copy of all audit reports.
Minimum requirements for the installation Contractor are as follows: Completed three or more jobs within the past two years applying the specified materials to concrete surfaces in which the total area exceeds 200,000 square feet. Submit documentation listing location of work, point of contact at job site, total square footage of applied materials, listing of both materials and equipment used, and validation from coating manufacturer documenting quality of materials purchased per job for work totaling 200,000 square feet within the past two years. In addition to the above requirements, to install the submitted coatings and sealant. Submit cope of certificates.
Replace with:
All Contractors that perform surface preparation or coating application must be certified prior to Contract award and must remain certified while accomplishing any surface preparation or coating application. The painting Contractors must remain so certified for the duration of the project. If a Contractor's certification expires, the firm will not be allowed to perform any work until the certification is reissued. Requests for extension of time for any delay to the completion of the project due to an inactive certification will not be considered. Notify the Contracting Officer of any change in Contractor certification status. Notify the Contracting Officer of all scheduled and unannounced on-site audits from SSPC and furnish a copy of all audit reports.
Minimum requirements for the installation Contractor are as follows: Completed three or more jobs within the past two years applying the specified materials to concrete surfaces in which the total area exceeds 200,000 square feet. Submit documentation listing location of work, point of contact at job site, total square footage of applied materials, listing of both materials and equipment used, and validation from coating manufacturer documenting quality of materials purchased per job for work totaling
200,000 square feet within the past two years. In addition to the above requirements, installation Contractor must be certified by the material manufacturer(s) to install the submitted coatings and sealant. Submit copy of certificates.
Remove the following Specification from the solicitation
Section 07 19 00
Section 07 42 13
Replace with the following Specification
Section 07 19 00
Section 07 42 13