Volume IIA_Amendment 004.pdf
PDF 4 MB Posted
- Solicitation number
- N69450-21-R0022
About this file
This federal solicitation seeks design-build construction services for a Flight Simulator Facility and Squadron Operations/Aircraft Maintenance Unit Facility at Naval Air Station Fort Worth Joint Reserve Base in Texas. The projects include demolishing existing buildings and site work totaling 8,009 square feet. The Flight Simulator Facility will be one story and 20,000 square feet, housing four full mission simulators. The Squadron Operations/Aircraft Maintenance Unit Facility will be two stories and 33,729 square feet, providing spaces for aircraft maintenance on the first floor and squadron operations on the second floor. Both facilities will have reinforced concrete foundations, structural steel frames, and standing seam metal roofs. Exterior walls will be 4-inch split face masonry. Windows will have insulated glass with laminated interior panes. The facilities' architectural appearance must comply with the installation plan. The secured portion of the Flight Simulator Facility will be constructed according to ICD 705 standards. Offers are due by the date specified in the solicitation issued by Naval Facilities Engineering Command Southeast.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
A
A-201
C1
A-202
A1 A-202
C1
A-201
A1
109111 112
121 122 123
125 126
ELEVATOR
A1
A-301
A1
A-301
C1
A-302
C1
A-302
A1
A-302
A1
A-302
C1
A-301
C1
A-301
B
D
E
F
2 3 4 5 6 7
1' - 4" 28' - 0" 33' - 3" 35' - 9" 37' - 0" 28' - 4" 21' - 8" 1' - 4"
1'
4"
1'
4"
C
0'
8"
50' - 0" 22' - 0" 114' - 8"
CANOPY
ABOVE
186' - 8"
142143
A R
E A
A
A R
E A
B
63' - 11" 8' - 0" 38' - 1" 12' - 0" 64' - 8"
STEEL SHELVING
(CFCI), REFER TO
SPEC 10 56 13
GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET AG001.
REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL
LOCATIONS. ALL FIRE RATED WALLS AND SMOKE PARTITIONS ARE
CONTINUOUS ACROSS ALL DOOR OPENINGS.
FOR PARTITION TYPES CONSTRUCTION AND DESCRIPTION REFER TO
PARTITION TYPES SHEET.
THE CONTRACTOR MUST VERIFY ALL DIMENSIONS, ELEVATIONS AND
SITE CONDITIONS BEFORE BEGINNING WORK AND FABRICATION.
THE GOVERNMENT MUST BE NOTIFIED IN WRITING IMMEDIATELY OF
ANY DISCREPANCIES OR INCONSISTENCIES. IN NO CASE MUST
DIMENSIONS BE SCALED OFF PLANS, SECTIONS, OR DETAILS FROM
THESE DRAWINGS.
FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,
REFER TO LARGER SCALE DRAWINGS.
DOOR LOCATIONS NOT DIMENSIONED ARE 6 INCHES FROM FACE OF
GYPSUM BOARD FINISH WALL TO DOOR JAMB FACE.
CONTRACTOR MUST COORDINATE AND PROVIDE ALL MILLWORK
TRIM AND INFILL PANELS AT ALL UNDERCOUNTER / CABINET
LOCATIONS.
REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL
FINISH INFORMATION. ALL FLOOR FINISHES TO BE CONTINUOUS
UNDER MILLWORK AND EQUIPMENT UNLESS NOTED OTHERWISE.
PROVIDE 18GA METAL PLATE OR FIRE TREATED WOOD BLOCKING IN
WALL FOR TOILET FIXTURES, ACCESSORIES, EQUIPMENT, FLOOR
AND WALL MOUNTED TOILET PARTITIONS, AND COUNTERTOP
MOUNTING SUPPORTS.
REFER TO SPECIFICATIONS FOR LOCATIONS OF GYPSUM BOARD
CONTROL JOINTS.
ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU
WALL, FINISH FACE OF METAL STUD WALL, UNLESS NOTED
OTHERWISE.
THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS
NOTED OTHERWISE.
PROVIDE GYPSUM BOARD HEADER ABOVE ALL CASED OPENINGS,
REFERENCE REFLECTED CEILING PLANS.
PROVIDE BLOCKING AS REQUIRED FOR ALL WALL MOUNTED
EQUIPMENT, INCLUDING MARKER BOARDS, TACK BOARDS AND
AUDIO / VISUAL EQUIPMENT.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
N A
S J
R B
F
O R
T W
O R
T H
T
X
N A
V Y
A
IR
S T
A T
IO
N
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
E X
A S
AS NOTED
U N
C L A
S S
IF
IE
D
KEY PLAN
A B
The Johnson-McAdams Firm P.A.
F
IL
E P
A T
H
P
LO
T T
E D
15154699
C
R e v it
P ro je c ts
\B L
D G
P
-1
-A
-O P
S -C
E N
T R
A L rn e d d o
.r v t
/1
/2
:4
:4
P M
A-101
F A
S Q
U A
D R
O N
O P
E R
A T
IO
N
S /A
M U
F A
C
IL
IT
Y
O V
E R
A
LL
G R
O U
N D
F
LO
O R
P
LA
N
KY
15154258
15154258
NAC HRN
JR / SM
1651220
N69450-19-D-0123
SCALE: 3/32" = 1'-0"
A1
OVERALL GROUND FLOOR PLAN
GENERAL NOTES
ROOM SCHEDULE - GROUND FLOOR
ROOM
NUMBER ROOM NAME AREA
134 BATTERY CHARGING 106 SF
135 BATTERY STORAGE 106 SF
136 COSO 624 SF
137 MECHANICAL ROOM 1,135 SF
138 ELECTRICAL ROOM 290 SF
139 STORAGE 111 SF
141 ELEVATOR MACHINE ROOM 74 SF
142 RESTROOM 49 SF
143 RESTROOM 47 SF
ROOM SCHEDULE - GROUND FLOOR
ROOM
NUMBER ROOM NAME AREA
123 ADO 303 SF
124 CORRIDOR 837 SF
125 VESTIBULE 130 SF
126 WORK CAFE 810 SF
127 RESTROOM 47 SF
128 SUPPORT EQUIPMENT / MAINTENANCE 5,326 SF
129 TECH ORDER LIBRARY 101 SF
131 FLIGHT CHIEF 111 SF
132 CHIEF OFFICE 110 SF
133 SUPPORT OFFICE 110 SF
ROOM SCHEDULE - GROUND FLOOR
ROOM
NUMBER ROOM NAME AREA
112 COMM ROOM 117 SF
113 STORAGE 176 SF
114 MASS BRIEFING 894 SF
115 RECEPTION 31 SF
116 A/V CLOSET 20 SF
117 HERITAGE ROOM 659 SF
118 FITNESS / AFE TRAINING 1,251 SF
119 HALL 200 SF
121 VESTIBULE 103 SF
122 FLIGHT CC 252 SF
ROOM SCHEDULE - GROUND FLOOR
ROOM
NUMBER ROOM NAME AREA
101 VESTIBULE 209 SF
102 CORRIDOR 600 SF
103 LOBBY 608 SF
104 MOTHER'S ROOM 111 SF
105 STAIR 256 SF
106 MEN'S RESTROOM 307 SF
107 MEN'S LOCKERS 224 SF
108 JANITOR 36 SF
109 WOMEN'S RESTROOM 207 SF
111 WOMEN'S LOCKERS 82 SF
0 8' 16' 24'
PLAN
NORTH
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R
T A
S U
B M
IT
T
A L
/2
2/
A
M E
N D
M E
N T
/1 3/
DN
A
A-201
C1
A-202
A1 A-202
C1
A-201
A1
ELEVATOR
205206
225 226 227
233 234
241242
243244
A1
A-301
A1
A-301
C1
A-302
C1
A-302
A1
A-302
A1
A-302
C1
A-301
C1
A-301
B
D
E
F
2 3 4 5 6 7
C
0'
8"
1'
4"
4'
1'
4"
1' - 4" 28' - 0" 33' - 3" 35' - 9" 37' - 0" 28' - 4" 21' - 8"
164' - 8"
1' - 0"
OPEN TO
BELOW
OPEN TO
BELOW
2" / 1'-0"
CANOPY
A R
E A
A
A R
E A
B
FIXED AUDITORUM
SEATING (CFCI), REFER
TO SPEC 12 61 13
GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET AG001.
REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL
LOCATIONS. ALL FIRE RATED WALLS AND SMOKE PARTITIONS ARE
CONTINUOUS ACROSS ALL DOOR OPENINGS.
FOR PARTITION TYPES CONSTRUCTION AND DESCRIPTION REFER TO
PARTITION TYPES SHEET.
THE CONTRACTOR MUST VERIFY ALL DIMENSIONS, ELEVATIONS AND
SITE CONDITIONS BEFORE BEGINNING WORK AND FABRICATION.
THE GOVERNMENT MUST BE NOTIFIED IN WRITING IMMEDIATELY OF
ANY DISCREPANCIES OR INCONSISTENCIES. IN NO CASE MUST
DIMENSIONS BE SCALED OFF PLANS, SECTIONS, OR DETAILS FROM
THESE DRAWINGS.
FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,
REFER TO LARGER SCALE DRAWINGS.
DOOR LOCATIONS NOT DIMENSIONED ARE 6 INCHES FROM FACE OF
GYPSUM BOARD FINISH WALL TO DOOR JAMB FACE.
CONTRACTOR MUST COORDINATE AND PROVIDE ALL MILLWORK
TRIM AND INFILL PANELS AT ALL UNDERCOUNTER / CABINET
LOCATIONS.
REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL
FINISH INFORMATION. ALL FLOOR FINISHES TO BE CONTINUOUS
UNDER MILLWORK AND EQUIPMENT UNLESS NOTED OTHERWISE.
PROVIDE 18GA METAL PLATE OR FIRE TREATED WOOD BLOCKING IN
WALL FOR TOILET FIXTURES, ACCESSORIES, EQUIPMENT, FLOOR
AND WALL MOUNTED TOILET PARTITIONS, AND COUNTERTOP
MOUNTING SUPPORTS.
REFER TO SPECIFICATIONS FOR LOCATIONS OF GYPSUM BOARD
CONTROL JOINTS.
ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU
WALL, FINISH FACE OF METAL STUD WALL, UNLESS NOTED
OTHERWISE.
THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS
NOTED OTHERWISE.
PROVIDE GYPSUM BOARD HEADER ABOVE ALL CASED OPENINGS,
REFERENCE REFLECTED CEILING PLANS.
PROVIDE BLOCKING AS REQUIRED FOR ALL WALL MOUNTED
EQUIPMENT, INCLUDING MARKER BOARDS, TACK BOARDS AND
AUDIO / VISUAL EQUIPMENT.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
N A
S J
R B
F
O R
T W
O R
T H
T
X
N A
V Y
A
IR
S T
A T
IO
N
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
E X
A S
AS NOTED
U N
C L A
S S
IF
IE
D
KEY PLAN
A B
The Johnson-McAdams Firm P.A.
F
IL
E P
A T
H
P
LO
T T
E D
15154699
C
R e v it
P ro je c ts
\B L
D G
P
-1
-A
-O P
S -C
E N
T R
A L rn e d d o
.r v t
/1
/2
:4
:4
P M
A-102
F A
S Q
U A
D R
O N
O P
E R
A T
IO
N
S /A
M U
F A
C
IL
IT
Y
O V
E R
A
LL
S E
C O
N D
F
LO
O R
P
LA
N
KY
15154259
15154259
NAC HRN
JR / SM
1651220
N69450-19-D-0123
SCALE: 3/32" = 1'-0"
B1
OVERALL SECOND FLOOR PLAN
GENERAL NOTES
ROOM SCHEDULE - SECOND FLOOR
ROOM
NUMBER ROOM NAME AREA
239 VAULT CIRCULATION 553 SF
241 MISSION PLANNING & WEAPONS 707 SF
242 CSSO (CVN) 411 SF
243 LARGE BRIEFING 404 SF
244 ISSO (CVN) 385 SF
245 ISSO / SECURE COMM 171 SF
246 SMALL BRIEFING 172 SF
247 SMALL BRIEFING 172 SF
248 SMALL BRIEFING 172 SF
249 SMALL BRIEFING 174 SF
251 LARGE BRIEFING 353 SF
ROOM SCHEDULE - SECOND FLOOR
ROOM
NUMBER ROOM NAME AREA
226 CONFERENCE ROOM 203 SF
227 CSS 243 SF
228 VESTIBULE 203 SF
229 ALIS ADMIN 259 SF
231 ALIS SERVER ROOM 656 SF
232 MAIN BRIEFING 885 SF
233 VESTIBULE 71 SF
234 WEAPONS OIC 232 SF
235 INTEL 745 SF
236 OIC 105 SF
237 SSR 106 SF
238 INTEL COMM 165 SF
ROOM SCHEDULE - SECOND FLOOR
ROOM
NUMBER ROOM NAME AREA
214 CORRIDOR 803 SF
215 MULTI-FUNCTION WORK AREA 182 SF
216 OPS ADMIN 440 SF
217 OPS ADMIN 111 SF
218 ACTIVE DUTY 164 SF
219 OPS DESK 305 SF
220 HALL 66 SF
221 TRAINING / STAN EVAL 296 SF
222 SCHEDULE 255 SF
223 DO 112 SF
224 CORRIDOR 477 SF
225 CC 196 SF
ROOM SCHEDULE - SECOND FLOOR
ROOM
NUMBER ROOM NAME AREA
201 STAIR 256 SF
202 LOBBY 301 SF
203 MEN'S RESTROOM 307 SF
204 MEN'S LOCKERS 224 SF
205 WOMEN'S RESTROOM 160 SF
206 WOMEN'S LOCKERS 82 SF
207 JANITOR 36 SF
208 ELECTRICAL ROOM 111 SF
209 MISSION PLANNING & ALIS ADMIN 542 SF
211 STORAGE 71 SF
212 COMM ROOM 129 SF
213 FIRST SGT 109 SF
0 8' 16' 24'
PLAN
NORTH
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R
T A
S U
B M
IT
T
A L
/2
2/
A
M E
N D
M E
N T
/1 3/
DN
DN
A
B
D
E
F
2 3 4 5 6 7
C
C2
A-107
C2
A-107
B2
A-107
B2
A-107
C1
A-107
C1
A-107
B1
A-107
B1
A-107
A
A
A A
A A
A A
A
A
AA B
A B
A
BA
B
A
A
A
A
B
B B B
B
A2
A-107
A2
A-107
A1
A-107
A1
A-107
F
F
F G
F
GENERAL AIR BARRIER NOTES:
1.
2.
SEE SPECIFICATION 07 27 10.00 10 BUILDING AIR BARRIER SYSTEM
TESTING FOR COMMISSIONING.
REFERENCE EXTERIOR DETAILS FOR CONTINUOUS AIR BARRIER.
CONTINUOUS AIR BARRIER DEFINITION
FULLY GROUTED CMU WALL WITH SPRAY APPLIED AIR BARRIER
ALUMINUM GLAZING SYSTEM
METAL STUD WALL WITH EXTERIOR SHEATHING AND SPRAY
APPLIED AIR BARRIER
SELF-ADHESIVE ICE / WATER SHIELD
CAST-IN-PLACE CONCRETE FLOOR SLAB
FULL HEIGHT PAINTED CMU WALL
FULL HEIGHT PAINTED GYPSUM BOARD AND METAL STUD WALL
(ALL AIR BARRIER SYSTEMS ON WALLS ARE FROM FLOOR TO
BOTTOM OF ROOF DECK OR CONNECT TO ROOF AIR BARRIER)
A
B
C
D
E
F
G
ZONE A
FLOOR AREA =
WALL AREA =
ROOF AREA =
AIR BARRIER ZONE LEGEND
ZONE B
FLOOR AREA =
WALL AREA =
ROOF AREA =
ZONE C
FLOOR AREA =
WALL AREA =
ROOF AREA =
AREAS LISTED BELOW ARE ROUGH ESTIMATES. CONTRACTOR MUST
FIELD VERIFY ALL ZONE AREAS AND ADJUST CALCULATIONS FOR
MAXIMUM LEAKAGE CFM AS REQUIRED.
ALLOWABLE LEAKAGE RATE = 0.40 CFM/SF
ZONE D
FLOOR AREA =
WALL AREA =
ROOF AREA =
AIR BARRIER LOCATION
34,355 SF x 0.40 = 13,742 CFM
(MAX LEAKAGE)
16,000 SF
18,200 SF
14,555 SF
7,660 SF x 0.40 = 3,064 CFM
(MAX LEAKAGE)
2,903 SF x 0.40 = 1,161 CFM
(MAX LEAKAGE)
410 SF x 0.40 = 164 CFM
(MAX LEAKAGE)
1,250 SF
5,260 SF
1,150 SF
290 SF
2,319 SF
294 SF
69 SF
272 SF
69 SF
A
B
D
E
F
2 3 4 5 6 7
C
C2
A-107
C2
A-107
B2
A-107
B2
A-107
C1
A-107
C1
A-107
B1
A-107
B1
A-107
A
A
C
A
A
A
A
BA B
B B B B
B
B B B B
A2
A-107
A2
A-107
A1
A-107
A1
A-107
A
F
F
F G
F
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
N A
S J
R B
F
O R
T W
O R
T H
T
X
N A
V Y
A
IR
S T
A T
IO
N
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
E X
A S
AS NOTED
U N
C L A
S S
IF
IE
D
The Johnson-McAdams Firm P.A.
F
IL
E P
A T
H
P
LO
T T
E D
15154699
C
R e v it
P ro je c ts
\B L
D G
P
-1
-A
-O P
S -C
E N
T R
A L rn e d d o
.r v t
/1
/2
:4
:5
P M
A-106
F A
S Q
U A
D R
O N
O P
E R
A T
IO
N
S /A
M U
F A
C
IL
IT
Y
A
IR
B A
R R
IE
R
P
LA
N F
LO
O
R P
LA
N
S
KY
15154263
15154263
NAC HRN
JR / SM
1651220
N69450-19-D-0123
SCALE: 1/16" = 1'-0"
C2
GROUND FLOOR AIR BARRIER PLAN
GENERAL NOTES
LEGEND
0 8' 16' 32'SCALE: 1/16" = 1'-0"
A2
SECOND FLOOR AIR BARRIER PLAN
0 8' 16' 32'
PLAN
NORTH
PLAN
NORTH
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R
T A
S U
B M
IT
T
A L
/2
2/
A
M E
N D
M E
N T
/1 3/
1 2 3 4 5 6 7
C1
A-107
C1
A-107
B1
A-107
B1
A-107
A
D
C
A
D
D
D
D
D E E
A1
A-107
A1
A-107
F
GENERAL AIR BARRIER NOTES:
1.
2.
SEE SPECIFICATION 07 27 10.00 10 BUILDING AIR BARRIER SYSTEM
TESTING FOR COMMISSIONING.
REFERENCE EXTERIOR DETAILS FOR CONTINUOUS AIR BARRIER.
CONTINUOUS AIR BARRIER DEFINITION
FULLY GROUTED CMU WALL WITH SPRAY APPLIED AIR BARRIER
ALUMINUM GLAZING SYSTEM
METAL STUD WALL WITH EXTERIOR SHEATHING AND SPRAY
APPLIED AIR BARRIER
SELF-ADHESIVE ICE / WATER SHIELD
CAST-IN-PLACE CONCRETE FLOOR SLAB
FULL HEIGHT PAINTED CMU WALL
FULL HEIGHT PAINTED GYPSUM BOARD AND METAL STUD WALL
(ALL AIR BARRIER SYSTEMS ON WALLS ARE FROM FLOOR TO
BOTTOM OF ROOF DECK OR CONNECT TO ROOF AIR BARRIER)
A
B
C
D
E
F
G
ZONE A
FLOOR AREA =
WALL AREA =
ROOF AREA =
AIR BARRIER ZONE LEGEND
ZONE B
FLOOR AREA =
WALL AREA =
ROOF AREA =
ZONE C
FLOOR AREA =
WALL AREA =
ROOF AREA =
AREAS LISTED BELOW ARE ROUGH ESTIMATES. CONTRACTOR MUST
FIELD VERIFY ALL ZONE AREAS AND ADJUST CALCULATIONS FOR
MAXIMUM LEAKAGE CFM AS REQUIRED.
ALLOWABLE LEAKAGE RATE = 0.40 CFM/SF
ZONE D
FLOOR AREA =
WALL AREA =
ROOF AREA =
AIR BARRIER LOCATION
34,355 SF x 0.40 = 13,742 CFM
(MAX LEAKAGE)
16,000 SF
18,200 SF
14,555 SF
7,660 SF x 0.40 = 3,064 CFM
(MAX LEAKAGE)
2,903 SF x 0.40 = 1,161 CFM
(MAX LEAKAGE)
410 SF x 0.40 = 164 CFM
(MAX LEAKAGE)
1,250 SF
5,260 SF
1,150 SF
290 SF
2,319 SF
294 SF
69 SF
272 SF
69 SF
1 2 3 4 5 6 7 C1
A-107
C1
A-107
B1
A-107
B1
A-107
A
A
D D D
C
D D
E
A1
A-107
A1
A-107
ABDEF C
C2
A-107
C2
A-107
B2
A-107
B2
A-107
D D
A
E
A
E B
B
A
B
B
A
E
A2
A-107
A2
A-107
ABDEF C
C2
A-107
C2
A-107
B2
A-107
B2
A-107
D D
C
E
A
A
B E
A2
A-107
A2
A-107
1 2 3 4 5 6 7
C1
A-107
C1
A-107
B1
A-107
B1
A-107
E E E A
D D
D
A
D
E
D
A1
A-107
A1
A-107
C G
F
G
ABDEF C
C2
A-107
C2
A-107
B2
A-107
B2
A-107
A2
A-107
A2
A-107
A
D D
E
E
E E
D D
A
F
F
F
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
N A
S J
R B
F
O R
T W
O R
T H
T
X
N A
V Y
A
IR
S T
A T
IO
N
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
E X
A S
AS NOTED
U N
C L A
S S
IF
IE
D
The Johnson-McAdams Firm P.A.
F
IL
E P
A T
H
P
LO
T T
E D
15154699
C
R e v it
P ro je c ts
\B L
D G
P
-1
-A
-O P
S -C
E N
T R
A L rn e d d o
.r v t
/1
/2
:4
:0
P M
A-107
F A
S Q
U A
D R
O N
O P
E R
A T
IO
N
S /A
M U
F A
C
IL
IT
Y
A
IR
B A
R R
IE
R
S E
C
TI
O N
S
KY
15154264
15154264
NAC HRN
JR / SM
1651220
N69450-19-D-0123
SCALE: 1/16" = 1'-0"
C2
AIR BARRIER SECTION
GENERAL NOTES
LEGEND
0 8' 16' 32'
SCALE: 1/16" = 1'-0"
B2
AIR BARRIER SECTION
SCALE: 1/16" = 1'-0"
C1
AIR BARRIER SECTION
SCALE: 1/16" = 1'-0"
B1
AIR BARRIER SECTION
0 8' 16' 32'
0 8' 16' 32'
0 8' 16' 32'0 8' 16' 32'
SCALE: 1/16" = 1'-0"
A2
AIR BARRIER SECTION
SCALE: 1/16" = 1'-0"
A1
AIR BARRIER SECTION
0 8' 16' 32'
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R
T A
S U
B M
IT
T
A L
/2
2/
A
M E
N D
M E
N T
/1 3/
A
A1
A-302
A1
A-302
C1
A-301
C1
A-301
C1
A-414
B3
A-403
B
D
E
F
4 5 6 7
4'
6"
5'
4" 3'
4"
2'
0"
3'
4"
2'
6"
11' - 8"
8' - 10"
2'
0" 3'
4"
A
LI
G N
A
LI
G N
128A
136A
118B
118A
122 123 126A 127
124A
124B
128B
VESTIBULE
CORRIDOR
FITNESS / AFE
TRAINING
HALL
VESTIBULE
121 FLIGHT CC
ADO
CORRIDOR
VESTIBULE
WORK CAFE
SUPPORT
EQUIPMENT /
MAINTENANCE
TECH ORDER
LIBRARY
FLIGHT CHIEF
CHIEF OFFICE
SUPPORT OFFICE
BATTERY
CHARGING
BATTERY
STORAGE
COSO
W1 W1 W1
37' - 0" 28' - 4" 21' - 8" 1' - 4"
21' - 6"
F1CA S2AA
S2AA F1CAS2AA
F1CA
M1CA
F1CA
M1CA
F1CA
F1CA
F1CA
M1CA
S2AA
S2AA
3'
4"
2'
0"
M1CA
S2AA M1CA
S2AA
M1CA
S2AA
M1CA
M1CB
M1CB
M1CB
M1CBM1CA
M1CB
S2AA
M1CB
M1CB M1CB
S2AA
M1CA
10' - 0"
2' - 8"
3' - 4" 4' - 8"
M1CA
S2AA
S2AA
F1CA
6'
4" 3'
8"
1'
4"
4'
1'
4"
37' - 0" 28' - 4" 21' - 8"
F1CA
46' - 1" 22' - 0"
5' - 4" 4' - 0" 5' - 4" 1' - 8"
2' - 4"
5' - 4"
12' - 0"
1'
4"
126B
C
0'
8"
S2AA
15' - 4" 4' - 0"11' - 8" 12' - 0"
PMA CHARGING
STATION
A
LI
G N
REMOVABLE SAFETY CHAIN,
REFER TO SPEC SECTION
05 52 00
4"
136B
125B
125A
M1CA
B4
A-581
1'
6"
BOLLARD EACH SIDE
OF OVERHEAD DOOR
RE: CIVIL
A2
A-451
A2
A-451
SIM
5' - 4"
1' - 4"
2' - 8" 5' - 4"
W1 W1
SF08
C2
A-451
12' - 0"
12' - 7 5/8"
11' - 11 5/8"
142143
RESTROOM
RESTROOM
RESTROOM
15' - 3 1/2"
A R
E A
A
A R
E A
B
4'
0"
9'
6"
4'
0"
6'
0"
6'
8" 3'
4"
6'
4" 3'
4"
3'
4" 8'
0"2'
4"
3'
4"
2'
0"
3'
4"
1'
0"
7'
4" 1'
0"
M1CA
M1CA
BELOW
COUNTER
A-404
A1
A2
A-572
A1
A-572
5 - 2 1/2" GROMMETS
EQUALLY SPACED
3 - 2 1/2" GROMMETS
EQUALLY SPACED
STORAGE
SHELVING (CFCI),
REFER TO SPEC
10 56 13
GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET AG001.
REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL
LOCATIONS. ALL FIRE RATED WALLS AND SMOKE PARTITIONS ARE
CONTINUOUS ACROSS ALL DOOR OPENINGS.
FOR PARTITION TYPES CONSTRUCTION AND DESCRIPTION REFER TO
PARTITION TYPES SHEET.
THE CONTRACTOR MUST VERIFY ALL DIMENSIONS, ELEVATIONS AND
SITE CONDITIONS BEFORE BEGINNING WORK AND FABRICATION.
THE GOVERNMENT MUST BE NOTIFIED IN WRITING IMMEDIATELY OF
ANY DISCREPANCIES OR INCONSISTENCIES. IN NO CASE MUST
DIMENSIONS BE SCALED OFF PLANS, SECTIONS, OR DETAILS FROM
THESE DRAWINGS.
FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,
REFER TO LARGER SCALE DRAWINGS.
DOOR LOCATIONS NOT DIMENSIONED ARE 6 INCHES FROM FACE OF
GYPSUM BOARD FINISH WALL TO DOOR JAMB FACE.
CONTRACTOR MUST COORDINATE AND PROVIDE ALL MILLWORK
TRIM AND INFILL PANELS AT ALL UNDERCOUNTER / CABINET
LOCATIONS.
REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL
FINISH INFORMATION. ALL FLOOR FINISHES TO BE CONTINUOUS
UNDER MILLWORK AND EQUIPMENT UNLESS NOTED OTHERWISE.
PROVIDE 18GA METAL PLATE OR FIRE TREATED WOOD BLOCKING IN
WALL FOR TOILET FIXTURES, ACCESSORIES, EQUIPMENT, FLOOR
AND WALL MOUNTED TOILET PARTITIONS, AND COUNTERTOP
MOUNTING SUPPORTS.
REFER TO SPECIFICATIONS FOR LOCATIONS OF GYPSUM BOARD
CONTROL JOINTS.
ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU
WALL, FINISH FACE OF METAL STUD WALL, UNLESS NOTED
OTHERWISE.
THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS
NOTED OTHERWISE.
PROVIDE GYPSUM BOARD HEADER ABOVE ALL CASED OPENINGS,
REFERENCE REFLECTED CEILING PLANS.
PROVIDE BLOCKING AS REQUIRED FOR ALL WALL MOUNTED
EQUIPMENT, INCLUDING MARKER BOARDS, TACK BOARDS AND
AUDIO / VISUAL EQUIPMENT.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
N A
S J
R B
F
O R
T W
O R
T H
T
X
N A
V Y
A
IR
S T
A T
IO
N
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
E X
A S
AS NOTED
U N
C L A
S S
IF
IE
D
KEY PLAN
A B
The Johnson-McAdams Firm P.A.
F
IL
E P
A T
H
P
LO
T T
E D
15154699
C
R e v it
P ro je c ts
\B L
D G
P
-1
-A
-O P
S -C
E N
T R
A L rn e d d o
.r v t
/1
/2
:4
:0
P M
A-112
F A
S Q
U A
D R
O N
O P
E R
A T
IO
N
S /A
M U
F A
C
IL
IT
Y
G R
O U
N D
F
LO
O R
P
LA
N
A R
E A
B
KY
15154268
15154268
NAC HRN
JR / SM
1651220
N69450-19-D-0123
SCALE: 1/8" = 1'-0"
A1
GROUND FLOOR PLAN - AREA B
GENERAL NOTES
0 4' 8' 16'
PLAN
NORTH
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R
T A
S U
B M
IT
T
A L
/2
2/
A
M E
N D
M E
N T
/1 3/
A
A-202
A1
A1
A-301
A1
A-301
C1
A-302
C1
A-302
C1
A-301
C1
A-301
A1
A-412
A1
A-407
B
D
E
F
2 3
213212
ELEVATOR
STAIR
LOBBY
MEN'S RESTROOM
MEN'S LOCKERS
WOMEN'S
RESTROOM
WOMEN'S
LOCKERS
JANITOR
ELECTRICAL
ROOM
MISSION
PLANNING & ALIS
ADMIN
STORAGE
COMM ROOM
FIRST SGT
CORRIDOR
MULTI-FUNCTION
WORK AREA
OPS ADMIN
OPS ADMIN
ACTIVE DUTY
TRAINING / STAN
EVAL
OPS DESK
SCHEDULE
DO
W1 W1
SF06
A
LI
G N
S2AD
S4AA
S4AA
M1CB
M1CB
M1CB
M1CB
M1CB
M1CB
F1CA
S4AA
S2AA S2AA S2AA
S2AD
S2AA
S2AD
F1CA
S2AD S2AA
S2AD
S2AA
S2AA
S2AA
S2AA
S2AA
S2AA
S2AA
S2AA
S2AA
S2AA
S2AA
S2AA
S2AA
S2AA
S2AA
S2AA
F1CA
F1CA
F1CA
F1CA
F1CA
4' - 0" 5' - 4" 7' - 4" 5' - 4" 5' - 4" 20' - 0"
1' - 4" 28' - 0" 33' - 3"
1'
4"
4'
1'
4"
7'
2"
ALIGN
4'
4" 3'
9' - 5" 12' - 7"
11"
8' - 8"
A
LI
G N
5' - 6" 10' - 2" 7' - 11"
S2AA
S4AA
5'
3"
30' - 8" 8' - 0" 11' - 4" 22' - 0"
1' - 4" 28' - 0" 33' - 3"
3' - 0" 7' - 6" 3' - 0" 4' - 4"
C
9' - 7"
0'
8"
S2AD
OPEN TO
BELOW
OPEN TO
BELOW
2'
6"
0"
S2AA
S2AA
S4AA
S2AD
7' - 5"
F1CA
C3
A-409
B4
A-410
L01
F1CA
F1BC
F1BC
M1CB
C4
A-451
STEEL GRATING AND
GUARD RAILING
SHIP'S LADDER
SF07
SF10
E W
C
A R
E A
A
A R
E A
B
L03
3'
1" 6'
3"
6'
8" 6'
0"
9'
ALIGN
1' - 4"
F1CB
F1CB
RECESSED
PHONE LOCKERS
A-410
B1
A1
GROMMET TYP.
HALL
GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET AG001.
REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL
LOCATIONS. ALL FIRE RATED WALLS AND SMOKE PARTITIONS ARE
CONTINUOUS ACROSS ALL DOOR OPENINGS.
FOR PARTITION TYPES CONSTRUCTION AND DESCRIPTION REFER TO
PARTITION TYPES SHEET.
THE CONTRACTOR MUST VERIFY ALL DIMENSIONS, ELEVATIONS AND
SITE CONDITIONS BEFORE BEGINNING WORK AND FABRICATION.
THE GOVERNMENT MUST BE NOTIFIED IN WRITING IMMEDIATELY OF
ANY DISCREPANCIES OR INCONSISTENCIES. IN NO CASE MUST
DIMENSIONS BE SCALED OFF PLANS, SECTIONS, OR DETAILS FROM
THESE DRAWINGS.
FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,
REFER TO LARGER SCALE DRAWINGS.
DOOR LOCATIONS NOT DIMENSIONED ARE 6 INCHES FROM FACE OF
GYPSUM BOARD FINISH WALL TO DOOR JAMB FACE.
CONTRACTOR MUST COORDINATE AND PROVIDE ALL MILLWORK
TRIM AND INFILL PANELS AT ALL UNDERCOUNTER / CABINET
LOCATIONS.
REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL
FINISH INFORMATION. ALL FLOOR FINISHES TO BE CONTINUOUS
UNDER MILLWORK AND EQUIPMENT UNLESS NOTED OTHERWISE.
PROVIDE 18GA METAL PLATE OR FIRE TREATED WOOD BLOCKING IN
WALL FOR TOILET FIXTURES, ACCESSORIES, EQUIPMENT, FLOOR
AND WALL MOUNTED TOILET PARTITIONS, AND COUNTERTOP
MOUNTING SUPPORTS.
REFER TO SPECIFICATIONS FOR LOCATIONS OF GYPSUM BOARD
CONTROL JOINTS.
ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU
WALL, FINISH FACE OF METAL STUD WALL, UNLESS NOTED
OTHERWISE.
THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS
NOTED OTHERWISE.
PROVIDE GYPSUM BOARD HEADER ABOVE ALL CASED OPENINGS,
REFERENCE REFLECTED CEILING PLANS.
PROVIDE BLOCKING AS REQUIRED FOR ALL WALL MOUNTED
EQUIPMENT, INCLUDING MARKER BOARDS, TACK BOARDS AND
AUDIO / VISUAL EQUIPMENT.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
N A
S J
R B
F
O R
T W
O R
T H
T
X
N A
V Y
A
IR
S T
A T
IO
N
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
E X
A S
AS NOTED
U N
C L A
S S
IF
IE
D
KEY PLAN
A B
The Johnson-McAdams Firm P.A.
F
IL
E P
A T
H
P
LO
T T
E D
15154699
C
R e v it
P ro je c ts
\B L
D G
P
-1
-A
-O P
S -C
E N
T R
A L rn e d d o
.r v t
/1
/2
:4
:0
P M
A-121
F A
S Q
U A
D R
O N
O P
E R
A T
IO
N
S /A
M U
F A
C
IL
IT
Y
S E
C O
N D
F
LO
O R
P
LA
N
A R
E A
A
KY
15154269
15154269
NAC HRN
JR / SM
1651220
N69450-19-D-0123SCALE: 1/8" = 1'-0"
A2
SECOND FLOOR PLAN - AREA A
GENERAL NOTES
0 4' 8' 16'
PLAN
NORTH
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R
T A
S U
B M
IT
T
A L
/2
2/
A
M E
N D
M E
N T
/1 3/
2' x 2' ACOUSTICAL CEILING TILE
GYPSUM BOARD - PAINT
RECESSED LIGHT
10' - 0" CEILING HEIGHT ABOVE FINISH FLOOR
HVAC AIR SUPPLY DIFFUSER
HVAC EXHAUST OR RETURN DIFFUSER
CABLE TRAY
STRUCTURAL STEEL BEAM
HVAC LAY-IN LINEAR AIR SUPPLY DIFFUSER
LIGHT FIXTURE - WALL MOUNTED
RE: ELECTRICAL
EXPOSED CEILING
WALL MOUNTED EXTERIOR FIXTURE
OTS
6" x 4' EMERGENCY LIGHT FIXTURE - RECESSED AND
SUSPENDED, RE: ELECTRICAL
EXIT SIGN
OPEN TO STRUCTURE
6" x 4' LIGHT FIXTURE - RECESSED AND SUSPENDED
RE: ELECTRICAL
2' x 4' EMERGENCY LIGHT FIXTURE - RECESSED
RE: ELECTRICAL
2' x 4' LIGHT FIXTURE - RECESSED
RE: ELECTRICAL
2' x 2' LIGHT FIXTURE - RECESSED
RE: ELECTRICAL
LINEAR PENDANT LIGHT FIXURE - SUSPENDED
RE: ELECTRICAL
CEILING LEGEND:
EXTERIOR STUCCO COATING SOFFIT SYSTEM
A
B
D
E
F
2 3
10' - 0"
VESTIBULE
CORRIDOR
LOBBY
STAIR
105MEN'S RESTROOM
MEN'S LOCKERS
JANITOR
WOMEN'S
RESTROOM
WOMEN'S
LOCKERS
COMM ROOM
STORAGE
MASS BRIEFING
RECEPTION
HERITAGE ROOM
VESTIBULE
MECHANICAL
ROOM
ELECTRICAL
ROOM
ELEVATOR
MACHINE ROOM
ELEVATOR
10' - 0"
8' - 0"
8' - 0"
8' - 0"
C
STORAGE
8' - 0"
8' - 0"
MOTHER'S ROOM
8' - 0"
10' - 0"
10' - 0"
9' - 6"
10' - 0"
10' - 0"
CANOPY
2'
4"
A
A -5
B
A -5
B
A -5
10' - 0"
11' - 4" B2
A-561
B
A -5
B
A -5
B
A -5
1' - 6"
10' - 0"
10' - 9"
11' - 6"
9' - 6"
9' - 6"
A
A -5
A
A -5
CENTER CEILING
GRID ON CORRIDOR
E Q
6'
0" E
Q
ALIGN
E Q
8'
0" E
Q
EQ EQ
9' - 10"
B1
A-561
B2
A-561
A R
E A
A
A R
E A
B
OTS
OTS
OTS
OTS
OTS
11' - 4"
A/V CLOSET
10' - 0"
START GRID AT EAST WALL
A
A -5
B1
A-561
24" x 24" CEILING ACCESS PANEL, COORDINATE PANEL LOCATION WITH
FIRE SUPRRESSION DRAWINGS
1. REFER TO OVERALL REFLECTED CEILING PLANS FOR REFLECTED
CEILING PLAN GENERAL NOTES.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
N A
S J
R B
F
O R
T W
O R
T H
T
X
N A
V Y
A
IR
S T
A T
IO
N
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
E X
A S
AS NOTED
U N
C L A
S S
IF
IE
D
KEY PLAN
A B
The Johnson-McAdams Firm P.A.
F
IL
E P
A T
H
P
LO
T T
E D
15154699
C
R e v it
P ro je c ts
\B L
D G
P
-1
-A
-O P
S -C
E N
T R
A L rn e d d o
.r v t
/1
/2
:4
:1
P M
A-151
F A
S Q
U A
D R
O N
O P
E R
A T
IO
N
S /A
M U
F A
C
IL
IT
Y
G R
O U
N D
F
LO
O R
R E
FL
E
C
TE
D C
E
IL
IN
G
P
LA
N
A R
E A
A
KY
15154271
15154271
NAC HRN
JR / SM
1651220
N69450-19-D-0123
SCALE: 1/8" = 1'-0"
A2
GROUND FLOOR REFLECTED CEILING PLAN AREA -A
LEGEND
0 4' 8' 16'
GENERAL NOTES
PLAN
NORTH
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R
T A
S U
B M
IT
T
A L
/2
2/
A
M E
N D
M E
N T
/1 3/
A
B
D
E
F
4 5 6 7
FITNESS / AFE
TRAINING
HALL
FLIGHT CC
ADO
CORRIDOR
VESTIBULE
WORK CAFE
RESTROOM
SUPPORT
EQUIPMENT /
MAINTENANCE
TECH ORDER
LIBRARY
FLIGHT CHIEF
CHIEF OFFICE
SUPPORT OFFICE
BATTERY
CHARGING
BATTERY
STORAGE
COSO
C
10' - 0"
10' - 0"
9' - 6"
9' - 6"
A R
E A
A
A R
E A
B
OTS
OTS
OTS
RESTROOM
RESTROOM
11' - 4"
24" x 24" CEILING
ACCESS PANEL
2' x 2' ACOUSTICAL CEILING TILE
GYPSUM BOARD - PAINT
RECESSED LIGHT
10' - 0" CEILING HEIGHT ABOVE FINISH FLOOR
HVAC AIR SUPPLY DIFFUSER
HVAC EXHAUST OR RETURN DIFFUSER
CABLE TRAY
STRUCTURAL STEEL BEAM
HVAC LAY-IN LINEAR AIR SUPPLY DIFFUSER
LIGHT FIXTURE - WALL MOUNTED
RE: ELECTRICAL
EXPOSED CEILING
WALL MOUNTED EXTERIOR FIXTURE
OTS
6" x 4' EMERGENCY LIGHT FIXTURE - RECESSED AND
SUSPENDED, RE: ELECTRICAL
EXIT SIGN
OPEN TO STRUCTURE
6" x 4' LIGHT FIXTURE - RECESSED AND SUSPENDED
RE: ELECTRICAL
2' x 4' EMERGENCY LIGHT FIXTURE - RECESSED
RE: ELECTRICAL
2' x 4' LIGHT FIXTURE - RECESSED
RE: ELECTRICAL
2' x 2' LIGHT FIXTURE - RECESSED
RE: ELECTRICAL
LINEAR PENDANT LIGHT FIXURE - SUSPENDED
RE: ELECTRICAL
CEILING LEGEND:
EXTERIOR STUCCO COATING SOFFIT SYSTEM
1. REFER TO OVERALL REFLECTED CEILING PLANS FOR REFLECTED
CEILING PLAN GENERAL NOTES.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
N A
S J
R B
F
O R
T W
O R
T H
T
X
N A
V Y
A
IR
S T
A T
IO
N
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
E X
A S
AS NOTED
U N
C L A
S S
IF
IE
D
KEY PLAN
A B
The Johnson-McAdams Firm P.A.
F
IL
E P
A T
H
P
LO
T T
E D
15154699
C
R e v it
P ro je c ts
\B L
D G
P
-1
-A
-O P
S -C
E N
T R
A L rn e d d o
.r v t
/1
/2
:4
:1
P M
A-152
F A
S Q
U A
D R
O N
O P
E R
A T
IO
N
S /A
M U
F A
C
IL
IT
Y
G R
O U
N D
F
LO
O R
R E
FL
E
C
TE
D C
E
IL
IN
G
P
LA
N
A R
E A
B
KY
15154272
15154272
NAC HRN
JR / SM
1651220
N69450-19-D-0123
SCALE: 1/8" = 1'-0"
A1
GROUND FLOOR REFLECTED CEILING PLAN - AREA B
LEGEND
0 4' 8' 16'
GENERAL NOTES
PLAN
NORTH
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R
T A
S U
B M
IT
T
A L
/2
2/
A
M E
N D
M E
N T
/1 3/
GROUND FLOOR
100' - 0"
TLP-3
SOILD SURFACE
SHOWER BASE,
SSF-2
TA-16
SSF-4
TLB-1TA-15TLB-1 TLP-3
TA-11
ML-1
GROUND FLOOR
100' - 0"
TA-10
TA-10
TLP-3
SOILD SURFACE
SHOWER BASE, SSF-2
SSF-4
TLB-1
ML-1
GROUND FLOOR
100' - 0"
TA-12
TA-10 TA-10
SSF-4
SOLID SURFACE
SHOWER BASE, SSF-2
TLP-3
1.
2.
DIMENSIONS WITH AN ASTERISK (*) INDICATE CLEAR DIMENSION.
REFER TO SHEET A-582 FOR TILE TRANSITION DETAILS.
6" 5'
0"
5'
6"
TLB-1
TLP-3
PAINT FINISH
RE: ROOM FINISH SCHEDULE
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
N A
S J
R B
F
O R
T W
O R
T H
T
X
N A
V Y
A
IR
S T
A T
IO
N
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
E X
A S
AS NOTED
U N
C L A
S S
IF
IE
D
The Johnson-McAdams Firm P.A.
F
IL
E P
A T
H
P
LO
T T
E D
15154699
C
R e v it
P ro je c ts
\B L
D G
P
-1
-A
-O P
S -C
E N
T R
A L rn e d d o
.r v t
/1
/2
:4
:1
P M
A-402
F A
S Q
U A
D R
O N
O P
E R
A T
IO
N
S /A
M U
F A
C
IL
IT
Y
G R
O U
N D
F
LO
O R
T O
IL
E
T R
O O
M E
LE
V
A
TI
O N
S
KY
15154291
15154291
NAC HRN
JR / SM
1651220
N69450-19-D-0123
SCALE: 1/4" = 1'-0" (A-401)
D1
MEN'S LOCKERS 107 - NORTH ELEVATION
SCALE: 1/4" = 1'-0" (A-401)
D2
MEN'S LOCKERS 107 - SOUTH ELEVATION
SCALE: 1/4" = 1'-0" (A-401)
D4
MEN'S LOCKERS 107 - EAST ELEVATION
GENERAL NOTES
TOILET ACCESSORY SCHEDULE
NUMBER DESCRIPTION
TA-01 PAIR OF GRAB BARS 36" LONG AND 30" LONG
TA-02 GRAB BARS 36" LONG
TA-03 WALL MOUNTED PAPER TOWEL DISPENSER
TA-04 WALL MOUNTED SOAP DISPENSER
TA-05 MIRROR - 48" TALL x WIDTH OF COUNTER
TA-06 COMBINATION TOWEL DISPENSER / WASTE RECEPTACLE
TA-08 TOILET TISSUE DISPENSER
TA-09 SANITARY NAPKIN AND TAMPON DISPOSAL
TA-10 SHOWER CURTAIN, ROD AND RINGS
TA-11 ROBE HOOK
TA-12 ABA GRAB BAR - SHOWER
TA-13 UTILITY SHELF WITH MOP AND BROOM HOLDERS
TA-14 ADA MIRROR, 24" WIDE X 36" HIGH
TA-15 LOCKER ROOM BENCH - 48" LENGTH
TA-16 VERTICAL MIRROR, 18" WIDE X 60" HIGH
LEGEND
0 2' 4' 8'0 2' 4' 8'0 2' 4' 8'
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R
T A
S U
B M
IT
T
A L
/2
2/
A
M E
N D
M E
N T
/1 3/
SCALE: 1/4" = 1'-0"
C4
TILE DETAIL
0 2' 4' 8'
1/4" REAVEAL
3 1/2"
4"
6 1/2"
3"
2' - 6"
2'
6"
1/
4"
CONTINUOUS NOMINAL LUMBER
3/4" SUBSTRATE W/ PLASTIC LAMINATE
CONTINUOUS 2" X 2" 1/4" STL TUBE, WELDED TO SAME SIZED
STL TUBING EMBEDDED IN ADJACENT WALL(S) AND SAME
SIZED STL TUBING VERTICAL MEMBERS SPACED 14" OC
NOMINAL LUMBER BETWEEN VERTICAL STL TUBING
NOMINAL LUMBER BETWEEN VERTICAL STL TUBING
RUBBER COVE BASE
CONTINUOUS 2" X 2" 1/4" STL TUBE, WELDED TO SAME SIZED
STL TUBING EMBEDDED IN ADJACENT WALL(S) AND SAME
SIZED STL TUBING VERTICAL MEMBERS SPACED 14" OC
3/4" SUBSTRATE W/
PLASTIC LAMINATE
CONTINUOUS 2" X 2" 1/4" STL TUBE,
WELDED TO SAME SIZED STL TUBING
EMBEDDED IN ADJACENT WALL(S)
3/4" SUBSTRATE WITH 1/2"
SOILD SURFACE COUNTERTOP
4"
1/
4"
SOLID SURFACE COUNTERTOP & FRONT PANEL -
FINISHED ON ALL VISIBLE SIDES
CONTINUOUS 2" X 2" 1/4" STL TUBE, WELDED TO SAME SIZED
STL TUBING EMBEDDED IN ADJACENT WALL(S) AND SAME
SIZED STL TUBING VERTICAL MEMBERS SPACED 14" OC
NOMINAL LUMBER BETWEEN VERTICAL STL TUBING
RUBBER COVE BASE
CONTINUOUS 2" X 2" 1/4" STL TUBE, WELDED TO SAME SIZED
STL TUBING EMBEDDED IN ADJACENT WALL(S) AND SAME
SIZED STL TUBING VERTICAL MEMBERS SPACED 14" OC
3/4" SUBSTRATE W/
PLASTIC LAMINATE
3/4" SUBSTRATE WITH 1/2"
SOILD SURFACE COUNTERTOP
8"
10"
3/4" SUBSTRATE W/ PLASTIC LAMINATE
3/4" SUBSTRATE W/ PLASTIC LAMINATE
SOILD SURFACE END PANEL - FINISHED
ON ALL VISIBLE SIDES
2' - 8"
2'
6"
3 1/2" 5"
8 1/2"
NATURAL OAK TRIM
WITH INSET PLEX TOP
2'
8' - 0"
PLAM
RB-1
EQ EQ EQ
4' - 0"
ADJUSTABLE SHELF
SUPPORT SYSTEM
CABINET INTERIOR, SHELVES,
AND DRAWER ASSEMBLIES:
PLASTIC LAMINATE
BASE - RE: ROOM
FINISH SCHEDULE
FINISHED FLOOR
RE: ROOM FINISH SCHEDULE
2'
1/4" PLEX TOP RECESSED IN TOP -
LOOSE LAY FOR REMOVAL
SOLID OAK TRIM - CLEAR
STAIN WITH URETHANE FINISH
E
105' - 5"
104' - 3"
FINISHED FLOOR
RE: ROOM FINISH SCHEDULE
FINISHED WALL
RE: ROOM FINISH SCHEDULE
2" X 2" X 1/4" PAINTED STEEL ANGLE
SUPPORT AT EACH COUNTER SUPPORT
3/4" PLYWOOD SUB-TOP WITH 14GA
STAINLESS STEEL COVERING - SEAMS MUST
BE SHOP FINISHED WELDED AND GROUND
SMOOTH, NO. 4 NON-DIRECTIONAL FINISH
CONTINUOUS HORIZONTAL
2 X 2 X 1/4" STEEL TUBE
2 X 2 X 1/4" HORIZONTAL AND
VERTICAL STEEL TUBES AT 6'-0" O.C.
BASE PLATE WITH
(4) ANCHOR BOLTS
T O
P O
F S
T E
E L
/ B O
T T
O M
O F
C O
U N
T E
R
2'
8"
TOP OF SHELF
TOP OF SHELF
CHROMED STEEL
BRACKETS @ 36" O.C. MAX
3/4" PLYWOOD SHELVING
WITH PLASTIC LAMINATE
FACE AND EDGE
1 1/2" x 1 1/2" LIGHT GAUGE ANGLE
WELDED TO EACH SIDE OF HORIZONTAL
TUBE, COUNTER ANCHORED TO ANGLES
1 1/2" x 1 1/2" LIGHT GAUGE ANGLE
WELDED TO HORIZONTAL TUBE,
COUNTER ANCHORED TO ANGLES
2' - 0"
2' - 4 3/8"
2" DIAMETER GROMMET
ELECTRICAL RACEWAY AT
SHELVES AND COUNTER
RE: ELECTRICAL
FINISHED FLOOR
RE: ROOM FINISH SCHEDULE
FINISHED WALL
RE: ROOM FINISH
SCHEDULE 2" X 2" X 1/4" PAINTED STEEL
ANGLE SUPPORT AT EACH
COUNTER SUPPORT
3/4" PLYWOOD SUB-TOP WITH 14GA
STAINLESS STEEL COVERING - SEAMS
MUST BE SHOP FINISHED WELDED
AND GROUND SMOOTH, NO. 4 NON-
DIRECTIONAL FINISH
3' - 1"
T O
P O
F S
T E
E L
/ B O
T T
O M
O F
C O
U N
T E
R
2'
8" 2' - 0"
CONTINUOUS HORIZONTAL
2 X 2 X 1/4" STEEL TUBE
2 X 2 X 1/4" HORIZONTAL AND
VERTICAL STEEL TUBES AT 6'-0" O.C.
BASE PLATE WITH
(4) ANCHOR BOLTS
1"
1 1/2" x 1 1/2" LIGHT GAUGE
ANGLE WELDED TO EACH SIDE
OF HORIZONTAL TUBE, COUNTER
ANCHORED TO ANGLES
1 1/2" x 1 1/2" LIGHT GAUGE ANGLE
WELDED TO HORIZONTAL TUBE,
COUNTER ANCHORED TO ANGLES
2" DIAMETER GROMMET
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
N A
S J
R B
F
O R
T W
O R
T H
T
X
N A
V Y
A
IR
S T
A T
IO
N
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
E X
A S
AS NOTED
U N
C L A
S S
IF
IE
D
The Johnson-McAdams Firm P.A.
F
IL
E P
A T
H
P
LO
T T
E D
15154699
C
R e v it
P ro je c ts
\B L
D G
P
-1
-A
-O P
S -C
E N
T R
A L rn e d d o
.r v t
/1
/2
:4
:2
P M
A-572
F A
S Q
U A
D R
O N
O P
E R
A T
IO
N
S /A
M U
F A
C
IL
IT
Y
M
IL
LW
O
R K
D E
TA
IL
S
EA
15154318
15154318
GA EM
JR / SM
1651220
N69450-19-D-0123
SCALE: 1 1/2" = 1'-0" (A-409)
C1
OPS DESK DETAIL
SCALE: 1 1/2" = 1'-0" (A-409)
C3
OPS DESK TRANSACTION TOP DETAIL
SCALE: 3/4" = 1'-0"
A4
MISSION PLANNING - MAP TABLE ELEVATION
SCALE: 1 1/2" = 1'-0"
B4
SECTION AT MAP TABLE
0 1/2' 1' 1 1/2'
0 1/2' 1' 1 1/2'
0 1/2' 1' 1 1/2' 0 1/2' 1' 1 1/2'
0 1/2' 1' 1 1/2'SCALE: 1 1/2" = 1'-0"
A1
PMA CHARGING MILLWORK DETAIL
SCALE: 1 1/2" = 1'-0"
A2
SECTION AT COUNTERTOP
0 1/2' 1' 1 1/2'
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R
T A
S U
B M
IT
T
A L
/2
2/
A
M E
N D
M E
N T
/1 3/
8" DIAMETER PIPE GUARD
POST WITH RADIUS TOP, 3'-6"
HIGH FILLED WITH CONCRETE,
PAINT YELLOW
FINISH FLOOR
1' - 6"
3'
6" M
IN
ELEVATION
PLAN
1'
0"
1' - 0"
12" x 12" x 1" STEEL
PLATE WITH (4)
CONCRETE ANCHORS
INTERIOR FACE OF
EXTERIOR WALL
1" DIAMETER ADHESIVE
ANCHOR WITH 8" EMBED MIN.
ALIGN
INTERIOR FACE OF
EXTERIOR WALL
SECOND FLOOR
116' - 0"
4'
0" 4'
0"
CORRIDOR
MISSION
PLANNING & ALIS
ADMIN
10' - 0"
10' - 6"
CEILING HEIGHT
CEILING HEIGHT
5/8" GYPSUM BOARD
EACH SIDE OF 3 5/8"
METAL STUDS
5/8" GYPSUM BOARD
EACH SIDE OF 3 5/8"
METAL STUDS
ACOUSTICAL
CEILING
ACOUSTICAL
CEILING
GLASS TYPE G4, REFER
TO GLAZING SCHEDULE.
EXPOSED EDGES MUST
BE POLISHED.
GLASS MOUNTING
HARDWARE, QUANTITY
AND TYPE BY GLASS
SUPPLIER
WOOD BLOCKING
WOOD BLOCKING
EQ EQ
GLASS MOUNTING
HARDWARE, QUANTITY
AND TYPE BY GLASS
SUPPLIER
FINISH FLOOR
NOTE: EXPOSED GLASS
EDGES MUST BE POLISHED
TILE BASE
TREATED 2X WOOD FRAMING
3/4" MARINE GRADE
PLYWOOD ON TREATED 2X
WOOD FRAMING
LOCKER
SCHEDULED PARTITION
RE: PLANS
1"
CEMENT BACKER BOARD
TILE FLOORING
CONCRETE FLOOR SLAB
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
N A
S J
R B
F
O R
T W
O R
T H
T
X
N A
V Y
A
IR
S T
A T
IO
N
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
E X
A S
AS NOTED
U N
C L A
S S
IF
IE
D
The Johnson-McAdams Firm P.A.
F
IL
E P
A T
H
P
LO
T T
E D
15154699
C
R e v it
P ro je c ts
\B L
D G
P
-1
-A
-O P
S -C
E N
T R
A L rn e d d o
.r v t
/1
/2
:4
:2
P M
A-581
F A
S Q
U A
D R
O N
O P
E R
A T
IO
N
S /A
M U
F A
C
IL
IT
Y
M
IS
C E
LL
A
N E
O U
S D
E
TA
IL
S
KY
15154319
15154319
NAC HRN
JR / SM
1651220
N69450-19-D-0123
SCALE: 3/4" = 1'-0"
B4
INTERIOR BOLLARD DETAIL
0 1' 2' 3'
SCALE: 1 1/2" = 1'-0" (A-410)
A3
PARTITION DETAIL
0 1/2' 1' 1 1/2' 0 1/2' 1' 1 1/2'SCALE: 1 1/2" = 1'-0"
A4
LOCKER BASE DETAIL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R
T A
S U
B M
IT
T
A L
/2
2/
A
M E
N D
M E
N T
/1 3/
SL
D O
O R
P E
R S
C H
E D
U
LE
SSL
SCHEDULE
DOOR PER
D O
O R
P E
R S
C H
E D
U
LE
SCHEDULE
DOOR PER
B
OH
D O
O R
P E
R S
C H
E D
U
LE
DOOR PER SCHEDULE
F
VISION
WINDOWS
A D O
O R
P E
R S
C H
E D
U
LE
A B
FIXED
PANEL
FIXED
PANEL
NL
SCHEDULE
DOOR PER
D O
O R
P E
R S
C H
E D
U
LE
A D
B C
A
SCHEDULE
DOOR PER A
B
S C
H E
D U
LE
D O
O R
P E
R
2 3
OVERHEAD COILING
DOOR FRAME BY DOOR
MANUFACTURER
DOOR PART OF STOREFRONT
GLAZING SYSTEM - REFER TO
STORE FRONT ELEVATIONS
A
SCHEDULE
DOOR PER A
B
S C
H E
D U
LE
D O
O R
P E
R
PER DOOR
MANUFACTURER,
COORDINATE
MASONRY LINTEL
HEIGHT
GLASS TYPES:
REFERENCE SPECIFICATION FOR GLASS TYPES
G1 1-1/16" INSULATED, LAMINATED, TINTED, LOW-E COATED.
NON-LAMINATED PANE IS TEMPERED.
G2 1-1/16" INSULATED, LAMINATED, CLEAR.
NON-LAMINATED PANE IS TEMPERED.
G3 1/4" TEMPERED.
G4 9/16" CLEAR LAMINATED.
DOOR SCHEDULE NOTES:
1.
2.
MINIMUM CLEAR OPENING WIDTH OF 50".
PROVIDE 1/2" UNDERCUT TO DOOR.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
N A
S J
R B
F
O R
T W
O R
T H
T
X
N A
V Y
A
IR
S T
A T
IO
N
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
E X
A S
AS NOTED
U N
C L A
S S
IF
IE
D
The Johnson-McAdams Firm P.A.
F
IL
E P
A T
H
P
LO
T T
E D
15154699
C
R e v it
P ro je c ts
\B L
D G
P
-1
-A
-O P
S -C
E N
T R
A L rn e d d o
.r v t
/1
/2
:4
:3
P M
A-601
F A
S Q
U A
D R
O N
O P
E R
A T
IO
N
S /A
M U
F A
C
IL
IT
Y
D O
O R
S C
H E
D U
LE
, D
O O
R
F R
A M
E T
Y P
E S
KY
15154321
15154321
NAC HRN
JR / SM
1651220
N69450-19-D-0123
DOOR AND FRAME LEGEND
FINISH
FF-1* FACTORY FINISHED
PA-4 PAINT
MATERIAL
AL ALUMINUM
HM HOLLOW METAL
STL STEEL
WD WOOD
SIZE
- SINGLE DOOR
PR PAIR OF DOORS
* REFERENCE DOOR OR FRAME SPECIFICATION
** FIELD APPLY PER PAINT SPECIFICATION FOR
APPLICABLE SUBSTRATE AND EXPOSURE.
DOOR SCHEDULE - GROUND FLOOR
DOOR
NUMBER
DOOR FRAME
ASSEMBLY
RATING STC
DETAIL
HARDWARE SET REMARKS
SIZE
TYPE MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILLPAIR DOOR WIDTH HEIGHT
101A PR. 3' - 0" 7' - 10" SL AL FF-1 3 AL FF-1 - - A1 / A-614 A1 / A-615 A1 / A-614 1.0 GLASS TYPE: G1
101B PR. 3' - 0" 7' - 10" SL AL FF-1 3 AL FF-1 - - B4 / A-615 A3 / A-615 B4 / A-615 11.0 GLASS TYPE: G2
105A - 3' - 8" 7' - 0" F WD FF-1 1.2 HM P-1 45 MIN - C3 / A-611 B3 / A-611 A3 / A-611 21.0
105B - 4' - 0" 7' - 2" SL AL FF-1 3 AL FF-1 - - B4 / A-614 B1 / A-615 SIM B4 / A-614 8.0 GLASS TYPE: G1
106 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 34.0
108 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 38.0 NOTE 2
109 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 34.0
111 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 35.0
112 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 22.0
113 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 41.0
114A - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 23.0
114B - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 23.0
116 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 36.0
117A - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 33.0
117B - 3' - 0" 7' - 10" SL AL FF-1 3 AL FF-1 - - B4 / A-616 B1 / A-615 SIM B4 / A-616 7.0 GLASS TYPE: G1
118A - 3' - 0" 7' - 0" NL WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 27.0
118B - 3' - 0" 7' - 0" NL WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 27.0
121A PR. 3' - 0" 7' - 10" SL AL FF-1 3 AL FF-1 - - B4 / A-615 A3 / A-615 B4 / A-615 12.0 GLASS TYPE: G2
121B PR. 3' - 0" 7' - 10" SL AL FF-1 3 AL FF-1 - - A1 / A-614 A1 / A-615 A1 / A-614 2.0 GLASS TYPE: G1
122 - 3' - 0" 7' - 0" NL WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 32.0
123 - 3' - 0" 7' - 0" NL WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 32.0
124A PR. 3' - 0" 7' - 0" F WD FF-1 1.2 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 26.0
124B PR. 3' - 0" 7' - 10" F-IN HM P-1 1.1 HM P-1 - - B4 / A-613 B4 / A-613 A4 / A-613 6.0
125A PR. 2' - 6" 7' - 0" SSL AL FF-1 4.1 AL FF-1 - - A2 / A-612 B4 / A-612 A2 / A-612 10.0 GLASS TYPE: G4, NOTE 1
125B PR. 2' - 6" 7' - 0" SSL AL FF-1 4.1 AL FF-1 - - A1 / A-612 C3 / A-612 A1 / A-612 10.1 GLASS TYPE: G4, NOTE 1
126A - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C3 / A-611 B3 / A-611 A3 / A-611 24.0
126B - 3' - 0" 7' - 10" SL AL FF-1 3 AL FF-1 - - B4 / A-616 B1 & C1 / A-615 B4 / A-616 7.0 GLASS TYPE: G1
127 - 3' - 0" 7' - 0" F WD FF-1 1.2 HM P-1 - - C3 / A-611 B3 / A-611 A3 / A-611 35.0 NOTE 2
128A - 3' - 0" 7' - 10" F-IN HM FF-1 1.1 HM P-1 - - B4 / A-613 B4 / A-613 A4 / A-613 3.0
128B - 10' - 0" 10' - 0" OH-C AL P-1 2 STL P-1 - - B1 / A-613 A1 / A-613 B1 / A-613 9.0
129 - 3' - 0" 7' - 0" F WD FF-1 1.2 HM P-1 - - C2 / A-611 B2 / A-611 A2 / A-611 29.0
131 - 3' - 0" 7' - 0" F WD FF-1 1.2 HM P-1 - - C2 / A-611 B2 / A-611 A2 / A-611 29.0
132 - 3' - 0" 7' - 0" F WD FF-1 1.2 HM P-1 - - C2 / A-611 B2 / A-611 A2 / A-611 29.0
133 - 3' - 0" 7' - 0" F WD FF-1 1.2 HM P-1 - - C2 / A-611 B2 / A-611 A2 / A-611 29.0
134 - 3' - 0" 7' - 0" F WD FF-1 1.2 HM P-1 45 MIN - C2 / A-611 B2 / A-611 A2 / A-611 39.0 NOTE 2
135 - 3' - 0" 7' - 0" F WD FF-1 1.2 HM P-1 45 MIN - C2 / A-611 B2 / A-611 A2 / A-611 39.0 NOTE 2
136A - 3' - 0" 7' - 0" F WD FF-1 1.2 HM P-1 - - C2 / A-611 B2 / A-611 A2 / A-611 32.0
136B - 7' - 4" 10' - 0" OH-C AL P-1 2 STL P-1 - - B1 / A-616 A1 / A-616 B1 / A-616 9.0
137 PR. 3' - 2" 7' - 10" F-IN HM FF-1 1.1 HM P-1 - - B4 / A-613 B4 / A-613 A4 / A-613 5.0
138 - 4' - 0" 7' - 10" F-IN HM FF-1 1.1 HM P-1 - - B4 / A-613 B4 / A-613 A4 / A-613 4.0
139 - 3' - 0" 7' - 0" F HM FF-1 1.2 HM P-1 45 MIN - C2 / A-611 B2 / A-611 A2 / A-611 43.0 NOTE 2
141 - 3' - 0" 7' - 2" F-IN HM FF-1 1.1 HM P-1 - - B4 / A-613 B4 / A-613 A4 / A-613 3.0
142 - 3' - 0" 7' - 0" F WD FF-1 1.2 HM P-1 - - C3 / A-611 B3 / A-611 A3 / A-611 35.0 NOTE 2
143 - 3' - 0" 7' - 0" F WD FF-1 1.2 HM P-1 - - C3 / A-611 B3 / A-611 A3 / A-611 35.0 NOTE 2
NOT TO SCALE
A2
DOOR TYPES
(DOOR FRAME)
TYPE A B
1.1 2" 2"
1.2 2" 4"
(FLUSH PANEL)
TYPE DESCRIPTION
F-IN FLUSH PANEL INSULATED
F FLUSH PANEL
(SPLIT LITE)
TYPE DESCRIPTION A B #
SL SPLIT LITE 10" 8" SEE REMARKS IN
DOOR SCHEDULE
(OVERHEAD COILING)
TYPE DESCRIPTION
OH-C COILING DOOR
(SLIDING SPLIT LITE)
TYPE DESCRIPTION A B #
NOT TO SCALE
A1
DOOR FRAME TYPES
SSL SLIDING SPLIT LITE 10" 5 1/2" SEE REMARKS IN
DOOR SCHEDULE
(DOOR FRAME)
TYPE A B
4.1 2" 8"
(NARROW LIGHT)
TYPE DESCRIPTION A B C D #
NL NARROW LITE 6" 43" 24" 4" G3
LEGEND
GENERAL NOTES
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R
T A
S U
B M
IT
T
A L
/2
2/
A
M E
N D
M E
N T
/1 3/
DOOR SCHEDULE NOTES:
1.
2.
MINIMUM CLEAR OPENING WIDTH OF 50".
PROVIDE 1/2" UNDERCUT TO DOOR.
GLASS TYPES:
REFERENCE SPECIFICATION FOR GLASS TYPES
G1 1-1/16" INSULATED, LAMINATED, TINTED, LOW-E COATED.
NON-LAMINATED PANE IS TEMPERED.
G2 1-1/16" INSULATED, LAMINATED, CLEAR.
NON-LAMINATED PANE IS TEMPERED.
G3 1/4" TEMPERED.
G4 9/16" CLEAR LAMINATED.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
N A
S J
R B
F
O R
T W
O R
T H
T
X
N A
V Y
A
IR
S T
A T
IO
N
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
E X
A S
AS NOTED
U N
C L A
S S
IF
IE
D
The Johnson-McAdams Firm P.A.
F
IL
E P
A T
H
P
LO
T T
E D
15154699
C
R e v it
P ro je c ts
\B L
D G
P
-1
-A
-O P
S -C
E N
T R
A L rn e d d o
.r v t
/1
/2
:4
:3
P M
A-602
F A
S Q
U A
D R
O N
O P
E R
A T
IO
N
S /A
M U
F A
C
IL
IT
Y
D O
O R
S C
H E
D U
LE
KY
15154322
15154322
NAC HRN
JR / SM
1651220
N69450-19-D-0123
DOOR SCHEDULE - SECOND FLOOR
DOOR
NUMBER
DOOR FRAME
ASSEMBLY
RATING STC
DETAIL
HARDWARE SET REMARKS
SIZE
TYPE MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILLPAIR DOOR WIDTH HEIGHT
201 - 3' - 8" 7' - 0" F WD FF-1 1.2 HM P-1 45 MIN - C3 / A-611 B3 / A-611 A3 / A-611 21.0
203 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 34.0
205 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 34.0
207 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 38.0 NOTE 2
208 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 45 MIN - C3 / A-611 B3 / A-611 A3 / A-611 40.0
211 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 42.0 NOTE 2
212 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 43.0
213 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 30.0
216 - 3' - 0" 7' - 0" NL WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 25.0
217 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 29.0
218 - 3' - 0" 7' - 0" NL WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 32.0
221 - 3' - 0" 7' - 0" NL WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 25.0
222 - 3' - 0" 7' - 0" NL WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 32.0
223 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 30.0
224 - 3' - 8" 7' - 10" SL AL FF-1 1.1 AL FF-1 - - B2 / A-616 C1 / A-615 B2 / A-616 7.1 GLASS TYPE: G1
225 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 30.0
226 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 31.0
227 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 32.0
228A - 3' - 6" 7' - 0" F HM P-1 1.1 HM P-1 - - C1 / A-611 B1 / A-611 A1 / A-611 18.0
228B - 3' - 0" 7' - 0" F HM P-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 13.0
229 - 3' - 6" 7' - 0" F HM P-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 14.0
231 - 3' - 6" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-45 C1 / A-611 B1 / A-611 A1 / A-611 15.0
232A - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 18.0
232B - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 17.0
233 - 3' - 0" 7' - 0" F HM P-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 13.0
234 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 19.0
235 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 20.0
236 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-45 C1 / A-611 B1 / A-611 A1 / A-611 28.0
237 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-45 C1 / A-611 B1 / A-611 A1 / A-611 28.0
238 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-45 C1 / A-611 B1 / A-611 A1 / A-611 19.0
239 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 16.0
242 - 3' - 0" 7' - 0" F HM P-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 14.0
243 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 19.0
244 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-45 C1 / A-611 B1 / A-611 A1 / A-611 14.0
245 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-45 C1 / A-611 B1 / A-611 A1 / A-611 19.0
246 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 19.0
247 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 19.0
248 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 19.0
249 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 19.0
251 - 3' - 0" 7' - 0" F WD FF-1 1.1 HM P-1 - STC-50 C1 / A-611 B1 / A-611 A1 / A-611 19.0
LEGEND
GENERAL NOTES
* REFERENCE DOOR OR FRAME SPECIFICATION
** FIELD APPLY PER PAINT SPECIFICATION FOR
APPLICABLE SUBSTRATE AND EXPOSURE.
DOOR AND FRAME LEGEND
FINISH
FF-1* FACTORY FINISHED
PA-4 PAINT
MATERIAL
AL ALUMINUM
HM HOLLOW METAL
STL STEEL
WD WOOD
SIZE
- SINGLE DOOR
PR PAIR OF DOORS
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
R
T A
S U
B M
IT
T
A L
/2
2/
A
M E
N D
M E
N T
/1 3/
LO
U
V E
R R
O U
G H
O P
E N
IN
G
H E
IG
H
T S
E E
S C
H E
D U
LE
BOND BEAM
RE: STRUCTURAL FOR
REINFORCEMENT
CMU WALL
CONTINUOUS SEALANT
(TYPICAL) EACH SIDELOUVER - SEE
LOUVER SCHEDULE
LOUVER FRAME
THRU WALL METAL
FLASHING
AIR SPACE
INTEGRALLY COLORED
VENEER MASONRY
SPRAY APPLIED
INSULATION (R-14)
CMU WALL
INSECT SCREEN
L 1 1/2 x 1 1/2" x 1/8"
ANGLE SUPPORT W/
1/4" DIA CONCRETE
ANCHORS @ 24" O.C. @
HEAD, JAMBS AND SILL
SILL FLASHING
CONTINUOUS SEALANT
EACH SIDE
GALVANIZED STEEL PLATE
RE: STRUCTURAL
INTEGRALLY COLORED
VENEER MASONRY
CONTINUOUS CLEAT
AIR SPACE
SPRAY APPLIED
INSULATION (R-14)
CONTINUOUS BEADS
OF SEALANT UNDER
SILL FLASHING
5"
1' - 8" @ 12" CMU WALL
1' - 4" @ 8" CMU WALL
8" OR 12" NOM
PROVIDE 4" TALL CELL
VENT WEEPS AT 16" O.C.,
INSTALL OVER FLASHING -
TYPICAL
GALVANIZED BENT
PLATE, PAINT TO MATCH
MASONRY COLOR
RE: STRUCTURAL
MORTAR NET
THRU WALL METAL
FLASHING
INTEGRALLY COLORED
VENEER MASONRY,
SMOOTH FACE AT END
OF BLOCK
4" NOM
CMU WALL
CONTINUOUS
SEALANT (TYPICAL)
EACH SIDE
AIR SPACE
SPRAY APPLIED
INSULATION (R-14)
1'
8"
2"
C M
U W
A
LL
1'
4"
C M
U W
A
LL
8" O
R
2" N
O M
4" N
O M
INTEGRALLY COLORED VENEER MASONRY,
SMOOTH FACE AT END OF BLOCK
LOUVER ROUGH OPENING WIDTH
SEE SCHEDULE
LOUVER - SEE
LOUVER SCHEDULE
LOUVER FRAME
INSECT SCREEN
L 1 1/2 x 1 1/2" x 1/8"
ANGLE SUPPORT W/ 1/4"
DIA CONCRETE ANCHORS
@ 24" O.C. @ HEAD,
JAMBS AND SILL
5"
SILL FLASHING
BELOW
INTEGRALLY COLORED,
SMOOTH FACED VENEER
MASONRY AT JAMB, TYPICAL
W
IN
D O
W R
O U
G H
O P
E N
IN
G
H E
IG
H
T S
E E
S C
H E
D U
LE
BOND BEAM
RE: STRUCTURAL FOR
REINFORCEMENT
CMU WALL
CONTINUOUS SEALANT
(TYPICAL) EACH SIDE
THRU WALL METAL FLASHING
AIR SPACE
INTEGRALLY COLORED VENEER
MASONRY MATCHING EXTERIOR
ELEVATION PATTERN
SPRAY APPLIED INSULATION
(R-14)
CMU WALL
SILL FLASHING
CONTINUOUS SEALANT
EACH SIDE
INTEGRALLY COLORED
VENEER MASONRY
CAST STONE SILL
AIR SPACE
SPRAY APPLIED
INSULATION (R-14)
ALUMINUM WINDOW FRAME,
SEE WINDOW SCHEDULE
SOLID SURFACE SILL
BLOCKING
CONTINUOUS BEADS OF
SEALANT UNDER SILL
FLASHING
CONTINUOUS SEALANT
WITH BACKER ROD
INTEGRALLY COLORED
VENEER MASONRY, SMOOTH
FACE AT END OF BLOCK
GYPSUM BOARD AND
METAL STUD WALL, SEE
FLOOR PLANS FOR TYPE
CONTINUOUS SEALANT
WITH BACKER ROD
SHIM
SHIM
BLOCKING
5" 2"
GALVANIZED STEEL ANGLE
RE: STRUCTURAL
1' - 4"
8" NOM
PROVIDE 4" TALL CELL VENT
WEEPS AT 16" O.C., INSTALL
OVER FLASHING - TYPICAL
GALVANIZED BENT PLATE, PAINT
TO MATCH MASONRY COLOR
RE: STRUCTURAL
MORTAR NET
THRU WALL METAL
FLASHING
4" NOM
4" N
O M
2"
CONTINUOUS SEALANT
WITH BACKER ROD
ROLLER WINDOW
SHADE
CMU WALL
AIR SPACE
SPRAY APPLIED
INSULATION (R-14)
8" N
O M
INTEGRALLY COLORED VENEER
MASONRY MATCHING EXTERIOR
ELEVATION PATTERN. SMOOTH
FACE AT JAMBS.
WINDOW ROUGH
OPENING WIDTH
SEE SCHEDULE
GYPSUM BOARD AND METAL
STUD WALL, SEE FLOOR
PLANS FOR TYPE
SILL FLASHING BELOW
SOLID SURFACE SILL BELOW
BLOCKING
CONTINUOUS SEALANT WITH
BACKER ROD EACH SIDE
ALUMINUM WINDOW FRAME,
SEE WINDOW SCHEDULE
1'
4"
4" N
O M
4"
S L
O P
E
S L
O P
E
SLOPE
CAST STONE
COURSE BELOW
CAST STONE SILL
5"
S L O
P E
D O
W N
AIR
SPACE
SPRAY APPLIED
INSULATION (R-14)CMU WALL
SILL FLASHING
INTEGRALLY
COLORED
VENEER
MASONRY
CAST STONE
SILL
AIR SPACE
SPRAY APPLIED
INSULATION (R-14)
SOLID SURFACE
SILL
INTEGRALLY
COLORED VENEER
MASONRY
GYPSUM BOARD AND METAL STUD WALL,
SEE FLOOR PLANS FOR TYPE
GALVANIZED STEEL
ANGLE
RE: STRUCTURAL
GYPSUM BOARD AND
METAL STUD WALL, SEE
FLOOR PLANS FOR TYPE
END DAM SILL
FLASHING
ALUMINUM
WINDOW
FRAME
GLAZING
ALUMINUM
WINDOW
FRAME
4"
CAST STONE
JOINT FOR SILL
UNIT
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
O U
T H
E A
S T
N A
S J
R B
F
O R
T W
O R
T H
T
X
N A
V Y
A
IR
S T
A T
IO
N
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
E X
A S
AS NOTED
U N
C L A
S S
IF
IE
D
The Johnson-McAdams Firm P.A.
F
IL
E P
A T
H
P
LO
T T
E D
15154699
C
R e v it
P ro je c ts
\B L
D G
P
-1
-A
-O P
S -C
E N
T R
A L rn e d d o
.r v t
/1
/2
:4
:3
P M
A-661
F A
S Q
U A
D R
O N
O P
E R
A T
IO
N
S /A
M U
F A
C
IL
IT
Y
W
IN
D O
W
L O
U…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .