SECTION J
DOCUMENTS, EXHIBITS, AND OTHER ATTACHMENTS
TABLE OF CONTENTS
ATTACHMENT
NUMBER
ATTACHMENT TITLE
J-1606000-01 Definitions and Acronyms J-1606000-02 References and Technical Documents J-1606000-03 Water Treatment and Distribution System Description J-1606000-04 Water Treatment and Distribution System Inventory J-1606000-05 Backflow Prevention Devices Inventory
ATTACHMENT J-1606000-01
DEFINITIONS AND ACRONYMS
Definition/Acronym Description ANSI American National Standards Institute AWWA American Water Works Association DoD FGS Department of Defense Environmental Final Governing Standards DoD OEBGD Overseas Environmental Baseline Guidance Document FFHC Fit For Human Consumption. Water that meets primary drinking water standards as defined by Final Governing Standards, Overseas Environmental Baseline Guidance Documents, and CNICINST 5090.1, and is safe for drinking, cooking, bathing, and other oral hygiene uses.
NFPA National Fire Protection Association NPDWR National Primary Drinking Water Regulations NSDWR National Secondary Drinking Water Regulations OMSI Operation And Maintenance Support Information UFC Unified Facilities Criteria USAPHC United States Army Preventive Health Command USEPA US Environmental Protection Agency
ATTACHMENT J-1606000-02
REFERENCES AND TECHNICAL DOCUMENTS
Document No. Document Title
UFC 3-440-02N Water Conservation Operation and Maintenance UFC 3-430-09 Exterior Mechanical Utility Distribution UFC 3-230-02 Water Supply Systems UFC 3-230-03 Water Supply: Water Treatment CNICINST 5090.1A U.S. Drinking Water Quality Standards for Navy Installations CNICINST 5090.2 Overseas Drinking Water Operation and Operator Requirements CNICINST 5090.3 Navy Overseas Drinking Water Program Ashore OPNAVINST 5090.1 Environmental Readiness Program Manual NAVMED P-5010-5 Water Supply Ashore UG-2029-ENV Cross-Connection Control and Backflow Prevention Program Implementation at
Navy Shore Facilities AWWA M14 Manual Cross Connection Control 9th Edition
NAVFACEURAFSWAINST
11330.1
Cross Connection Control and Backflow Prevention Program
ATTACHMENT J-1606000-03
Raw Water, Water Treatment and Distribution Systems Description
The NSF Redzikowo water system is a groundwater system that obtains raw water from two wells. These wells provide water for domestic/industrial use and fire protection; the drinking water system and the fire protection system are separate, but share the same source water wells. The well heads are located approximately 90 meters (290 feet) west of the WSB. The wells have an inside diameter of 400 millimeters (mm) (16 inches) and include wire wrapped stainless-steel well screens. Each Pump Capacity is rated at 10 L/s or 160 gpm to provide redundancy. The individual wells tie into each other where pre-chlorination occurs, this can be observed through the manhole inside of the well area. As the water enters the WSB, the water is divided between the fire suppression system and the drinking water system. The drinking water meter is located inside of the WSB where the total flow is measured. After, the flow meter in the system water is sent to the dual multi-media filters.
These filters are comprised of sand, rock and Pyrolox, and designed for removal of iron and manganese. During the process of filtration, air is injected in to the multimedia to induce the oxidization process. Once water leaves the multimedia process it enters the drinking water tanks. While in the water storage tanks, chlorine is injected for disinfection to occur. Finished water storage is provided by a vertical, steel ground storage tank with a capacity of 135 m³ (35,700 gallons).
The current distribution system includes 7 standing buildings, 2 water hydrants. Each building had an electronic water meter for flow measurement and is taken daily.
ATTACHMENT J-1606000-04
Raw Water, Water Treatment and Distribution Systems Inventory
Bldg Location Equipment Description Equipment ID Capacity
Qty Remarks
Site Raw Water Well Submersible Pump P-3019101 1
Site Raw Water Well Submersible Pump P-3019202 1
30 Exterior Storage Tank Potable Water T-3012001 106,370 L 1
30 Mechanical Equipment Room Storage Tank Potable Water T-3012201 3000 L 1 Potable Water Hydropneumatic Tank
30 Mechanical Equipment Room Storage Tank Potable Water T-3012101 3000 L 1 Potable Water Hydropneumatic Tank
30 Exterior Storage Tank – Fire System T-3052001 397,360 L 1
30 Exterior Storage Tank – Fire System T-3052002 397,360 L 1
30 PW Storage Tank Heat Exchanger TWH-3022003 Storage Tank Heating - PW
30 Fire Storage Tank Heat Exchanger TWH-3022001 Storage Tank Heating - Fire
30 Fire Storage Tank Heat Exchanger TWH-3022002 Storage Tank Heating - fire
30 Mechanical Equipment Room Pressurization Pump P-3012101 11 KW 1 Potable Water Booster Pump
30 Mechanical Equipment Room Pressurization Pump P-3012101 11 KW 1 Potable Water Booster Pump
30 Mechanical Equipment Room Sodium Hypochlorite Tank T-3007001 420 L 1
30 Mechanical Equipment Room Water Treatment Metering Pump P-3007101 0.14 KW 1 To Distribution Line
30 Mechanical Equipment Room Water Treatment Metering Pump P-3007201 0.14 KW 1 To Tank Inlet
30 Mechanical Equipment Room Electric Hot Water Boiler B-3022001 83 L 1 Water Storage Tank Heating, Bldg.
30 Space Heating
30 Mechanical Equipment Room Heating Water Pump P-3022101 2.2 KW 1 Water Storage Tank Heating, Bldg.
30 Space Heating
30 Mechanical Equipment Room Heating Water Pump P-3022201 2.2 KW 1 Water Storage Tank Heating, Bldg.
30 Space Heating
30 Mechanical Equipment Room Expansion Tank ET-3022001 30 L 1 Heating Water
30 Mechanical Equipment Room Air Separator AS-3022001 1 L 1 Heating Water
30 Mechanical Equipment Room Automatic Backflush Strainer Unit ST-3019001
ATTACHMENT J-1606000-05
Backflow Prevention Devices Inventory
Bldg Location Equipment Description Equipment ID
30 Mechanical Equipment Room Backflow Preventer BFP-3060001
30 Mechanical Equipment Room Backflow Preventer BFP-3019001