This document contains a solicitation for a firm-fixed price contract and a related request for specification clarification. The solicitation is for maintenance, repair, and preservation work on the Caisson One vessel, including blasting and preserving the hull and tanks, hull corrosion weld repairs, pump and tank cleaning, hatch and alarm system repairs, and ventilation system cleaning. The work must be performed at the contractor's ship repair facility located in the Puget Sound, Washington region between June 28, 2022 and December 12, 2022. The Navy seeks responses from ship repair contractors with facilities capable of drydocking the 94-foot vessel. The request for clarification pertains to the alarm system equipment manufacturers. The solicitation will result in a lowest-price technically acceptable award in late May 2022 under NAICS code 336611 and is posted on Sam.gov.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR SPECIFICATION CLARIFICATION (RFC)
DATE OF REQUEST: 2/4/2022 QUESTION NO: 00001
REQUIREMENT: CAISSON ONE REQUISITION NO.: N4523A22R1050
ITEM NO: 400-00-001
TITLE: Caisson Alarm Systems and Equipment Test;
accomplish
ISSUING OFFICE POC (CODE 440.22):
Brian Fergus brian.fergus@navy.mil Charles Smith charles.r.smith13@navy.mil
PARA. NO: 3.1.1 PAGE NO: 2 of 6 CONTRACTOR:
PLANNER’S NAME: ATTACH. NO: CONTRACTOR POC & PHONE:
CONTRACTOR QUESTION:
Item 400-00-001 Para 3.1.1 states to accomplish the requirements of 009-90 for the equipment identified in para 1.3.1. Looking over the provided reference drawings there is nothing indicating who the manufacturer of the system is. Please provide who the OEM of the equipment identified in para 1.3.1 would be.
DO NOT WRITE BELOW THIS LINE
SPEC CHG: No DWG/REF CHG. No RQMTS CHG: No MAT'L CHG: No
TECHNICAL REVIEW: DL SERIAL NO:
The system consists of three smoke detectors: AFT- Gentex Model S1209F, Middle/FWD- ESL Sentrol Inc Model 320CXH. The smoke detectors are attached to junction boxes and configured in series. When one of the alarms is activated, all alarms are then activated and a light is activated on the TLI panel. An alarm/beacon on the weather deck is also activated.
ALL REQUESTS FOR CLARIFICATION MUST BE RECEIVED BY THE ISSUING OFFICE POC NO
LATER THAN THE DATE & TIME IDENTIFIED IN THE REQUEST FOR PROPOSAL.