The associated federal contract opportunity (Solicitation Number N4008523R2849) is for Facilities Investment Services for Preventive Maintenance, Repair, and Alteration of Heating, Ventilation, and Air Conditioning (HVAC) Equipment. The contract will have a base period with four one-year option periods, not to exceed 60 months total. The selected contractor will be required to provide all labor, management, supervision, tools, material, equipment, and other items necessary to perform the HVAC services at the designated sites. All prospective contractors must have an active registration in the System for Award Management (SAM) database to be eligible for award. The solicitation is being issued by the Department of the Navy Naval Facilities Engineering Command.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REGION EQ LIST
| BLDG. | I.D.# | DESCRIPTION | MFG - M/N - S/N | LOCATION | CUSTOMER | BELTS | AIR FILTERS | COOLING | REFRIGERANT | NOTES |
| 1 | 1-1 | 100 TON CHILLER | CARRIER | ATTIC CENTER | REGION | DX/ CW | R134A | |||
| 1 | 1-1-5 | COOLING TOWER | BAC - VC1-65-KMPU | ATTIC | REGION | (2) B66 | ||||
| 1 | *1-1-1 | WEST AHU 5 h.p. | CARRIER - 39THCDXMF-R-AEL-AB | ATTIC WEST SIDE | REGION | B41 | (3) 20X25X2 | CW | ||
| 1 | *1-1-2 | CENTER AHU 7.5 h.p. | CARRIER - 39THDDXMF-R-AFJ-AB | ATTIC CENTER SECT | REGION | B56 | (4) 16X25X2 (2) 16X20X2 | CW | ||
| 1 | *1-1-3 | EAST AHU 5 h.p. | CARRIER - 39THDDXMF-R-AFJ-AB | ATTIC EAST SIDE | REGION | B36 | (2) 25X25X2 | CW | ||
| 1 | *1-1-4 | MEZZ. AHU 2 h.p. | CARRIER 39LF06AA-CLFBJJB59 | MEZZ. LEVEL EAST | REGION | B30 | (2) 20X20X2 | CW | ||
| 1 | *H3 | IN LINE HUMIDIFIER (Attached to Carrier AHU 1-1-3) | NORTEC - NHTC+0202 | ATTIC WEST SIDE | REGION | Canister Type | ||||
| 1 | *H2 | IN LINE HUMIDIFIER (Attached to Carrier AHU 1-1-2) | NORTEC - NHTC+0203 | ATTIC CENTER SECT | REGION | Canister Type | ||||
| 1 | *H1 | IN LINE HUMIDIFIER (Attached to Carrier AHU 1-1-1) | NORTEC - NHTC+0204 | ATTIC EAST SIDE | REGION | Canister Type | ||||
| 1 | *H4 | IN LINE HUMIDIFIER (Attached to Carrier AHU 1-1-4) | DRISTEEM VAPORMIST - VM99-4 | MEZZ LEVEL EAST | REGION | Canister Type | ||||
| 1 | 1-1-1P | C.W. CIRC PUMP | BELL & GOSSETT | ATTIC CENTER | REGION | |||||
| 1 | 1-1-2P | C.W. CIRC PUMP | BELL & GOSSETT | ATTIC CENTER | REGION | |||||
| 1 | 1-1-3P | H.W. CIRC PUMP | BELL & GOSSETT | ATTIC CENTER | REGION | |||||
| 1 | 1-1-4P | H.W. CIRC PUMP | BELL & GOSSETT | ATTIC CENTER | REGION | |||||
| 1 | Pump # 5 | H.W. CIRC PUMP | BELL & GOSSETT | ATTIC CENTER | REGION | MARKED AS P5 ON MOTOR | ||||
| 1 | Pump # 6 | H.W. CIRC PUMP | BELL & GOSSETT | ATTIC CENTER | REGION | MARKED AS P6 ON MOTOR | ||||
| 1 | 1-1-5P | IN-LINE CENTRIFUGAL HOT WATER CIRC PUMP | BELL & GOSSET - LQD56A17D60F | ATTIC | REGION | MARKED AS P1 | ||||
| 1 | 1-1-6P | IN-LINE CENTRIFUGAL HOT WATER CIRC PUMP | BELL & GOSSET - LQD56A17D60F | ATTIC | REGION | MARKED AS P2 | ||||
| 1 | 1-1-7P | IN-LINE CENTRIFUGAL HOT WATER CIRC PUMP | BELL & GOSSET - LQD56A17D60F | ATTIC | REGION | MARKED AS P3 | ||||
| 1 | 1-NGB-1 | HOT WATER BOILER (NATURAL GAS) | LOCHINVAR - KBN601 | ATTIC | REGION | MARKED AS B1 BTU=600,000 | ||||
| 1 | 1-NGB-2 | HOT WATER BOILER (NATURAL GAS) | LOCHINVAR - KBN601 | ATTIC | REGION | MARKED AS B2 BTU =600,000 | ||||
| 1 | 1-NGB-3 | HOT WATER BOILER (NATURAL GAS) | LOCHINVAR - KBN701 | ATTIC | REGION | MARKED AS B3 BTU+700,000 | ||||
| 1 | P0002569 | FAN COIL UNIT HEATER (HW) | TRANE - UHSA126S8EAA1T00B0000 | ATTIC EAST SIDE, ABOVE AHU 1-1-3 | REGION | D/D | ASSET P0002569 | |||
| 1 | P0002516 | FAN COIL UNIT HEATER (HW) | TRANE - UHSA126S8EAA1T00B0001 | ATTIC CENTER, NEXT TO CHILLER | REGION | D/D | ASSET P0002516 | |||
| 56 | *56-1 | 7.5 TON PKG UNIT | CARRIER M/N 48FCEM08A2A5A0A0A0 - S/N 0923P35479 | ROOF WEST SIDE | REGION | D/D | (4) 16X20X2 | DX | R-410A | ASSET P0002633 |
| 56 | *56-2 | 10 TON PKG UNIT | CARRIER - M/N 48FCEM12A2A5A0A0A0 - S/N1223P3K7128 | ROOF WEST SIDE | REGION | D/D | (4) 20X20X2 | DX | R-410A | ASSET P0002632 |
| 56 | *56-3 | 8.5 TON PKG UNIT | YORK - M/N ZF102N12R2A1AAA1A2- S/N N2N1833909 | ROOF EAST SIDE (SERVES PD ADMIN) | REGION | A54 | (4) 20X24X2 | DX | R-410A | ASSET P0002625 |
| 56 | 56-4 | 3-TON AHU UNIT | CARRIER - M/N FAACNF036000AAAA - S/N 0807A82805 | ATTIC | REGION | D/D | 20X20X1 | DX | R-22 | ASSET P0002638 |
| 56 | 56-4A | 3-TON CONDENSING UNIT | CARRIER M/N PH13NR036-K - S/N 1914X71568 | ROOF WEST SIDE | REGION | D/D | DX | R-22 | ASSET P0002635 | |
| 56 | P0002635 | IN-LINE HUMIDIFIER (Attached to 56-2 PKG UNIT) | APRILAIRE - M/N 600A - S/N N/A | 2ND FL SLEEP QTR | REGION | ASSET P0002639, Canister Type | ||||
| 56 | 56-AHU-5 | AHU (COOLING & HEATING) | REZNOR M/N PDH150-S - S/N EBLJ836EN05337 | GYM/ ABOVE CEILING GRID | REGION | A36 | (2) 20X25X2 | DX | ASSET P0002644 | |
| 56 | 56-IRH-3 | GAS-FIRED INFRARED HEATER | ROBERTS GORDON - M/N EP201 - S/N 1205-0011-0061 | 1ST FLOOR FIREHOUSE | REGION | ASSET P0002669 | ||||
| 56 | 56-IRH-4 | GAS-FIRED INFRARED HEATER | ROBERTS GORDON - M/N CTH3-115 -S/N 1206-034-115-0026 | 1ST FLOOR FIREHOUSE | REGION | ASSET P0002668 | ||||
| 56 | 56-IRH-5 | GAS-FIRED INFRARED HEATER | ROBERTS GORDON - M/N CTH3-115- S/N 1207-034-115-0036 | 1ST FLOOR FIREHOUSE | REGION | ASSET P0002667 | ||||
| 56 | 56-IRH-6 | GAS-FIRED INFRARED HEATER | ROBERTS GORDON - M/N CTH3-115 - S/N 1206-034115-0027 | 1ST FLOOR FIREHOUSE | REGION | ASSET P0002666 | ||||
| 56 | 56-IRH-7 | GAS-FIRED INFRARED HEATER | ROBERTS GORDON - M/N CTH3-80- S/N 1108-034-080-0036 | 1ST FLOOR FIREHOUSE | REGION | ASSET P0002665 | ||||
| 56 | 56-IRH-9 | GAS-FIRED INFRARED HEATER | ROBERTS GORDON - M/N CTH3-115 -S/N 1207-034-115-0034 | 1ST FLOOR FIREHOUSE | REGION | ASSET P0002664 | ||||
| 56 | 56-IRH-10 | GAS-FIRED INFRARED HEATER | ROBERTS GORDON - M/N CTH3-115 -S/N 1207-034-115-0035 | 1ST FLOOR FIREHOUSE | REGION | ASSET P0002663 | ||||
| 56 | UH1 | GAS-FIRED UNIT HEATER | MODINE - M/N N/A - S/N N/A | 1ST FL SOUTHEAST GARAGE BAY | REGION | D/D | ASSET P000 | |||
| 56 | P0002631 | 12T OUTDOOR S/S HEAT PUMP UNIT | MITSUBISHI M/N PUHY-P144TNU-A - S/N 9ZP00058 | NORTH WEST ROOF (SERVES FD) | REGION | D/D | DX | R410A | ASSET P0002631 | |
| 56 | P0002627 | 1T OUTDOOR S/S HEAT PUMP UNIT | MITSUBISHI M/N PUZ-A12NKA7 - S/N 83U07158B | SOUTH EAST ROOF (SERVES PD) | REGION | D/D | DX | R410A | ASSET P0002627 | |
| 56 | P0002648 | INDOOR S/S HEAT PUMP UNIT | MITSUBISHI M/N PLFY-P12NFMU-E - S/N 94M00782 | CAPT. OFFICE FD, CEILING MOUNT | REGION | D/D | WASHABLE | DX | R410A | ASSET P0002648 |
| 56 | P0002649 | INDOOR S/S HEAT PUMP UNIT | MITSUBISHI M/N PLFY-P12NFMU-E - S/N 8YM03724 | MARSHALL OFFICE FD, CEILING MOUNT | REGION | D/D | WASHABLE | DX | R410A | ASSET P0002649 |
| 56 | P0002650 | INDOOR S/S HEAT PUMP UNIT | MITSUBISHI M/N PLFY-EP24NEMU-E - S/N 98A07193D | CONFERENCE RM FD, CEILING MOUNT | REGION | D/D | WASHABLE | DX | R410A | ASSET P0002650 |
| 56 | P0002651 | INDOOR S/S HEAT PUMP UNIT | MITSUBISHI M/N PLFY-P12NFMU-E - S/N 8YM03727 | UNION OFFICE FD, CEILING MOUNT | REGION | D/D | WASHABLE | DX | R410A | ASSET P0002651 |
| 56 | P0002671 | INDOOR S/S HEAT PUMP UNIT | MITSUBISHI M/N PKA-A12HA7 - S/N 9XA20827A | LOCKER RM PD, WALL MOUNT | REGION | D/D | WASHABLE | DX | R410A | ASSET P0002671 |
| 545 | *545-1 | 30T PACKAGE UNIT | TRANE M/N SXHFC3040Z48C6CD7001A0D00G00000000Y8000 - S/N C01H57787 | S.E. EXTERIOR GROUND | REGION | SF - RF | (16) 20X20X2 | DX | R-22 | ASSET P0002587 |
| 545 | 545-1-1 | HW REHEAT COIL | TRANE - M/N N/A- S/N N/A | S.E. OFFICES /ABOVE CEILING GRID | REGION | N/A | N/A | N/A | ||
| 545 | 545-VAV-1 | VAV | TRANE - M/N VSWE17301V01100DD033000000000 - S/N R01H28721C | OFFICES/ ABOVE CEILING GRID | REGION | D/D | 16X16X1 | ASSET P0002615 | ||
| 545 | *545-VAV-2 | VAV | TRANE - M/N VSWE11111V01100DD033000000000 - S/N R01H28722C | OFFICES/ ABOVE CEILING GRID | REGION | D/D | 12X16X1 | ASSET P0002614 | ||
| 545 | *545-VAV-3 | VAV | TRANE - M/N VSWE17151V01100DD033000000000 - S/N R01H28725C | OFFICES/ ABOVE CEILING GRID | REGION | D/D | 15X20X1 | ASSET P0002616 | ||
| 545 | *545-VAV-4 | VAV | TRANE - M/N VSWE11111V011100DD033000000000 - S/N R01H28723C | OFFICES/ ABOVE CEILING GRID | REGION | D/D | 12X16X1 | ASSET P0002617 | ||
| 545 | *545-VAV-5 | VAV | TRANE - M/N VSWE17151V01100DD033000000000 - S/N R01H28728C | OFFICES/ ABOVE CEILING GRID | REGION | D/D | 15X20X1 | ASSET P0002619 | ||
| 545 | *545-VAV-6 | VAV | TRANE - M/N VSWE17151V01100DD033000000000 - S/N R01H28726C | OFFICES/ ABOVE CEILING GRID | REGION | D/D | 15X20X1 | ASSET P0002620 | ||
| 545 | *545-VAV-7 | VAV | TRANE - M/N VSWE11111V01100DD033000000000 - S/N R01H28724C | OFFICES/ ABOVE CEILING GRID | REGION | D/D | 12X16X1 | ASSET P0002621 | ||
| 545 | *545-VAV-8 | VAV | TRANE - M/N VSWE17201V01100DD033000000000 - S/N R01H28729C | OFFICES/ ABOVE CEILING GRID | REGION | D/D | 15X20X1 | ASSET P0002622 | ||
| 545 | *545-VAV-9 | VAV | TRANE - M/N VSWE17151V01100DD033000000000 - S/N R01H28727C | OFFICES/ ABOVE CEILING GRID | REGION | D/D | 15X20X1 | ASSET P0002623 | ||
| 545 | ATC | ATC | UTILITY CLOSET/ WEST | REGION | ||||||
| 545 | 545-NGB-1 | HOT WATER BOILER (NATURAL GAS) BTU =400,000 | LOCHINVAR - M/N CHN0402 - S/N G12H00242020 | WAREHOUSE/ MECH ROOM EAST | REGION | (1) 12X12X1 -Combustion Air Filter | ASSET P0002592 | |||
| 545 | 545-NGB-2 | HOT WATER BOILER (NATURAL GAS) BTU =400,000 | LOCHINVAR - M/N CHN0402 - S/N G12H00242021 | WAREHOUSE/ MECH ROOM EAST | REGION | (1) 12X12X1 -Combustion Air Filter | ASSET P0002593 | |||
| 545 | 545-HWCP-1 | IN-LINE CENTRIFUGAL HOT WATER CIRC PUMP | BELL & GOSSETT | WAREHOUSE/ MECH ROOM EAST | REGION | ASSET P0002594 | ||||
| 545 | 545-HWCP-2 | IN-LINE CENTRIFUGAL HOT WATER CIRC PUMP | BELL & GOSSETT | WAREHOUSE/ MECH ROOM EAST | REGION | ASSET P0002595 | ||||
| 545 | 545-HWCP-3 | IN-LINE CENTRIFUGAL HOT WATER CIRC PUMP | BELL & GOSSETT | WAREHOUSE/ MECH ROOM EAST | REGION | ASSET P0002596 | ||||
| 545 | 545-HWCP-4 | IN-LINE CENTRIFUGAL HOT WATER CIRC PUMP | BELL & GOSSETT | WAREHOUSE/ MECH ROOM EAST | REGION | ASSET P0002597 | ||||
| 545 | 545-ARU-1 | AIR ROTATION UNIT | POWRMATIC - M/N TE-11 - S/N 0912-22707-03 | WAREHOUSE AREA | REGION | BX49 | (3) 16X16X2 (6) 16X20X2 (3) 20X20X2 (1) 16X35X2 | ASSET P0002602 | ||
| 545 | 545-ARU-2 | AIR ROTATION UNIT | POWRMATIC - M/N TE-11 - S/N 0912-22707-01 | WAREHOUSE AREA | REGION | BX49 | (3) 16X16X2 (6) 16X20X2 (3) 20X20X2 (1) 16X35X2 | ASSET P0002601 | ||
| 545 | 545-ARU-3 | AIR ROTATION UNIT | POWRMATIC - M/N TE-11 - S/N 0912-22707-02 | WAREHOUSE AREA | REGION | BX49 | (3) 16X16X2 (6) 16X20X2 (3) 20X20X2 (1) 16X35X2 | ASSET P0002600 | ||
| 545 | P0002889 | UNIT HEATER | DAYTON - M/N 2HDA1 - S/N N/A | MECH ROOM/ CLOSET SOUTH | REGION | D/D | ASSET P0002589 | |||
| 1082 | P0002315 | HOT WATER BOILER (NATURAL GAS) | LOCHINVAR - M/N KBN601 - S/N N/A | MECHANICAL ROOM | REGION | ASSET P0002315 | ||||
| 1082 | P0002316 | HOT WATER BOILER (NATURAL GAS) | LOCHINVAR - M/N KBN601 - S/N N/A | MECHANICAL ROOM | REGION | ASSET P0002316 | ||||
| LEGEND | ||||||||||
| * = YEAR ROUND OPERATION | ||||||||||
| DX= DIRECT EXPANSION COOLING | ||||||||||
| CW= CHILLED WATER | ||||||||||
| HW= HEATING WATER | ||||||||||
| ATC= AUTOMATED TEMPURATURE CONTROLS | ||||||||||
| AHU= AIR HANDLING UNIT | ||||||||||
| MUA= MAKE UP AIR UNIT | ||||||||||
| ARU= AIR ROTATION UNIT | ||||||||||
| RTU= ROOFTOP PACKAGE UNIT | ||||||||||
| VAV= VARIABLE AIR VOLUME UNIT | ||||||||||
| PTAC= PACKAGE TERMINAL AC UNIT | ||||||||||
| S/S= AC SPLIT SYSTEM | ||||||||||
| EF= EXHAUST FAN | ||||||||||
| WU= WINDOW AC UNIT | ||||||||||
| D/D= DIRECT DRIVE | ||||||||||
| M/N= MODEL NUMBER | ||||||||||
| S/N= SERIAL NUMBER |
&LPNBC HVAC
&CREGION EQUIPMENT LIST
&RJ-1502000-01
&L* Indicates Year Round Operation
NFPC EQ LIST
| BLDG.# | I.D.# | DESCRIPTION | MFG - M/N - S/N | LOCATION | CUSTOMER | BELTS | AIR FILTERS | COOLING | REFRIGERANT | NOTES |
| 20 | 20-ARU-1 | AIR ROTATION UNIT | POWRMATIC - TE-41 | INDOOR | NFPC | YES | YES | |||
| 20 | 20-ARU-2 | AIR ROTATION UNIT | POWRMATIC - TE-42 | INDOOR | NFPC | YES | YES | |||
| 20 | 20-ARU-3 | AIR ROTATION UNIT | POWRMATIC -TE-43 | INDOOR | NFPC | YES | YES | |||
| 20 | 20-ARU-4 | AIR ROTATION UNIT | POWRMATIC - TE-44 | INDOOR | NFPC | YES | YES | |||
| 20 | 20-ARU-5 | AIR ROTATION UNIT | POWRMATIC - TE-45 | INDOOR | NFPC | YES | YES | |||
| 20 | 20-MAU-1 | MAKE-UP AIR UNIT | POWRMATIC - GA MODELS | ROOFTOP UNIT | NFPC | |||||
| 20 | 20-MAU-2 | MAKE-UP AIR UNIT | POWRMATIC - GA MODELS | ROOFTOP UNIT | NFPC | |||||
| 20 | 20-MAU-3 | MAKE-UP AIR UNIT | POWRMATIC - GA MODELS | ROOFTOP UNIT | NFPC | |||||
| 20 | 20-MAU-4 | MAKE-UP AIR UNIT | POWRMATIC - GA MODELS | ROOFTOP UNIT | NFPC | |||||
| 20 | 20-MAU-5 | MAKE-UP AIR UNIT | POWRMATIC - GA MODELS | ROOFTOP UNIT | NFPC | |||||
| 20 | 20-MAU-6 | MAKE-UP AIR UNIT | POWRMATIC - GA MODELS | ROOFTOP UNIT | NFPC | |||||
| 20 | 20-MAU-7 | MAKE-UP AIR UNIT | POWRMATIC - GA MODELS | ROOFTOP UNIT | NFPC | |||||
| 20 | 20-MAU-8 | MAKE-UP AIR UNIT | POWRMATIC - GA MODELS | ROOFTOP UNIT | NFPC | |||||
| 20 | 20-AHU-1 | AIR HANDLING UNIT | YORK - JZOZJN32P4AAA1 | ROOFTOP UNIT | NFPC | YES | R-410A | |||
| 20 | 20-AHU-2 | AIR HANDLING UNIT | REZNOR -PCDH-150 | ROOFTOP UNIT | NFPC | YES | R-410A | |||
| 20 | 20-SS-1 | SPLIT SYSTEM - CONDENSER | SANYO | Mezzanine at the Northwest Corner | NFPC | |||||
| 20 | 20-SS-1-1 | SPLIT SYSTEM EVAPORATOR | SANYO | Radiographic Storage Area | NFPC | D/D | WASHABLE | |||
| *49 | 49-SS-1 | MINI SPLIT SYSTEM CONDENSER UNIT HEAT PUMP | DAIKIN-2MXS18GVJU | ON GROUND SOUTH EAST CORNER | NFPC | DX | R-410A | |||
| *49 | 49-SS-1-1 | MINI SPLIT SYSTEM EVAPORATOR HEAD | DAIKIN | METROLOGY ROOM 1ST FLOOR | NFPC | D/D | WASHABLE | DX | R-410A | |
| *49 | 40-SS-1-2 | MINI SPLIT SYSTEM EVAPORATOR HEAD | DAIKIN | METROLOGY ROOM 1ST FLOOR | NFPC | D/D | WASHABLE | DX | R-410A | |
| *49 | 49-SS-2 | MINI SPLIT SYSTEM CONDENSER UNIT HEAT PUMP | DAIKIN-RXS09LVJU | ON GROUND EAST SIDE | NFPC | DX | R-410A | |||
| *49 | 49-SS-2-1 | MINI SPLIT SYSTEM EVAPORATOR HEAD | DAIKIN | METROLOGY OFFICE 1ST FLOOR | NFPC | D/D | WASHABLE | DX | R-410A | |
| *49 | 49-SS-3 | MINI SPLIT SYSTEM CONDENSER UNIT HEAT PUMP | MITSUBISHI | MOUNTED ON WALL EAST SIDE 2ND FLOOR | NFPC | DX | R-410A | |||
| *49 | 49-SS-3-1 | MINI SPLIT SYSTEM EVAPORATOR HEAD | MITSUBISHI | BREAKROOM 2ND FLOOR | NFPC | D/D | WASHABLE | DX | R-410A | |
| *49 | 49-SS-4 | MINI SPLIT SYSTEM CONDENSER UNIT HEAT PUMP | MITSUBISHI | MOUNTED ON WALL UNDER STAIRWELL ON SOUTHSIDE | NFPC | DX | R-410A | |||
| *49 | 49-SS-4-1 | MINI SPLIT SYSTEM EVAPORATOR HEAD | MITSUBISHI | COMPUTER ROOM | NFPC | D/D | WASHABLE | DX | R-410A | |
| *49 | 49-SS-5 | MINI SPLIT SYSTEM CONDENSER UNIT HEAT PUMP | MITSUBISHI- PUH24EK | ON GROUND SOUTH SIDE | NFPC | DX | R-410A | |||
| *49 | 49-SS-5-1 | MINI SPLIT SYSTEM EVAPORATOR HEAD | MITSUBISHI | 1ST FLOOR SUPPLY ROOM | NFPC | D/D | WASHABLE | DX | R-410A | |
| *49 | 49-SS-6 | MINI SPLIT CONDENSER UNIT HEAT PUMP | MITSUBISHI | MOUNTED ON WALL ON SOUTHSIDE 1ST FLOOR | NFPC | DX | R-410A | |||
| *49 | 49-SS-6-1 | MINI SPLIT SYSTEM EVAPORATOR HEAD | MITSUBISHI | 1ST FLOOR FEEDS OFFICE NEXT TO MAINTENANCE SUPERVISOR OFFICE | NFPC | D/D | WASHABLE | DX | R-410A | |
| *49 | 49-SS-7 | MINI SPLIT CONDENSER UNIT HEAT PUMP | MITSUBISHI | MOUNTED ON WALL ON THE WEST SIDE 2ND FLOOR | NFPC | DX | R-410A | |||
| *49 | 49-SS-7-1 | MINI SPLIT SYSTEM EVAPORATOR HEAD | MITSUBISHI | 2ND FLOOR FEEDS OFFICE ON OTHER SIDE OF WALL | NFPC | D/D | WASHABLE | DX | R-410A | |
| *49 | 49-SS-8 | MINI SPLIT SYSTEM CONDENSER UNIT HEAT PUMP | MITSUBISHI | MOUNTED ON WALL ON WEST SIDE 2ND FLOOR | NFPC | DX | R-410A | |||
| *49 | 49-SS-8-1 | MINI SPLIT SYSTEM EVAPORATOR HEAD | MITSUBISHI | 2ND FLOOR FEEDS OFFICE ON OTHER SIDE OF WALL | NFPC | D/D | WASHABLE | DX | R-410A | |
| *49 | 49-SS-9 | MINI SPLIT SYSTEM CONDENSER UNIT HEAT PUMP | MITSUBISHI | MOUNTED ON WALL ON NORTH SIDE | NFPC | DX | R-410A | |||
| *49 | 49-SS-9-1 | MINI SPLIT SYSTEM EVAPORATOR HEAD | MITSUBISHI | 1ST FLOOR OFFICE ON NORTHSIDE OF BUILDING | NFPC | D/D | WASHABLE | DX | R-410A | |
| *49 | 49-SS-10 | MINI SPLIT SYSTEM CONDENSER UNIT HEAT PUMP | MITSUBISHI | MOUNTED ON WALL ON NORTH SIDE | NFPC | DX | R-410A | |||
| *49 | 49-SS-10-1 | MINI SPLIT SYSTEM EVAPORATOR HEAD | MITSUBISHI | 1ST FLOOR OFFICE ON NORTHSIDE OF BUILDING | NFPC | D/D | WASHABLE | DX | R-410A | |
| *49 | 49-SS-11 | MINI SPLIT SYSTEM CONDENSER UNIT HEAT PUMP | MITSUBISHI | MOUNTED ON WALL ON NORTH SIDE | NFPC | DX | R-410A | |||
| *49 | 49-SS-11-1 | MINI SPLIT SYTEM EVAPORATOR HEAD | MITSUBISHI | 2ND FLOOR FEEDS OFFICE ON OTHER SIDE OF WALL | NFPC | D/D | WASHABLE | DX | R-410A | |
| *49 | 49-SS-12 | MINI SPLIT SYSTEM CONDENSER UNIT HEAT PUMP | DAIKIN | MOUNTED ON WALL ON NORTH SIDE | NFPC | DX | R-410A | |||
| *49 | 49-SS-12-1 | MINI SPLIT SYSTEM EVAPORATOR HEAD | DAIKIN | FEEDS LOCKER ROOM ON 2ND FLOOR | NFPC | D/D | WASHABLE | DX | R-410A | |
| 546 | 546-2 | 230 TON CHILLER | TRANE CHILLER UNIT | OUTSIDE OF BLDG. 546 - EAST SIDE | NFPC | |||||
| 546 | 546-1 | 230 TON SCREW CHILLER | YORK #YCAS0230EC46X | OUTSIDE OF BLDG. 546 - EAST SIDE | NFPC | FREQUENCY DRIVE A | ||||
| 546 | AHU-1 | 40-TON AIR HANDLER UNIT | YORK #CP680DWDIAF40 | OUTSIDE OF BLDG. 546 - EAST SIDE | NFPC | YES | ALL | CW | ||
| 546 | AHU-2 | 40-TON AIR HANDLER UNIT | YORK #CP680DWDIAF40 | OUTSIDE OF BLDG. 546 - EAST SIDE | NFPC | YES | ALL | CW | ||
| 546 | P-1 | C.W. CIRC PUMP | INSIDE BLDG. 546 - EAST SIDE | NFPC | 25 HP | |||||
| 546 | P-2 | C.W. CIRC PUMP | INSIDE BLDG. 546 - EAST SIDE | NFPC | 40 HP | |||||
| 546 | 546-ARU-1 | AIR ROTATION UNIT | POWRMATIC | INSIDE BLDG. 546 | NFPC | YES | YES | GAS FIRED TYPE | ||
| 546 | 546-ARU-2 | AIR ROTATION UNIT | POWRMATIC | INSIDE BLDG. 546 | NFPC | YES | YES | GAS FIRED TYPE | ||
| 546 | 546-ARU-3 | AIR ROTATION UNIT | POWRMATIC | INSIDE BLDG. 546 | NFPC | YES | YES | GAS FIRED TYPE | ||
| 546 | DDC-1 | DDC - PROGRAMMABLE LOOP CONTROLLER | KMC | DDC CABINET LOCATED INSIDE BLDG. 546 WEST SIDE WALL OF MACHINE SHOP | NFPC | NOTE: The DDC system is a specialized design control system. It is recommended that Core subcontract and coordinate their efforts concerning this system through Vortechs Automation, Inc. POC @ Vortechs is Walter Horigan at (215)322-6788. | ||||
| 592 | 592-ARU-1 | AIR ROTATION UNIT | POWRMATIC -TE-41 | 2N FLOOR (TOP FLOOR OF BLDG.) | NFPC | YES | YES | GAS FIRED TYPE | ||
| 592 | 592-ARU-2 | AIR ROTATION UNIT | POWERMATIC | 1ST FLOOR NW LOW BAY | NFPC | YES | YES | GAS FIRED TYPE | ||
| 592 | 592-ARU-3 | AIR ROTATION UNIT | POWERMATIC | 1ST FLOOR SW LOW BAY | NFPC | YES | YES | GAS FIRED TYPE | ||
| 592 | 592-GUH-1 | GAS UNIT HEATER | 1ST FLOOR WEST BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-GUH-2 | GAS UNIT HEATER | 1ST FLOOR WEST BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-GUH-3 | GAS UNIT HEATER | 1ST FLOOR WEST BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-GUH-4 | GAS UNIT HEATER | 1ST FLOOR WEST BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-GUH-5 | GAS UNIT HEATER | 1ST FLOOR WEST BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-GUH-6 | GAS UNIT HEATER | 1ST FLOOR WEST BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-GUH-7 | GAS UNIT HEATER | 1ST FLOOR WEST BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-GUH-8 | GAS UNIT HEATER | 2ND FLOOR MEZZANINE | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-GUH-9 | GAS UNIT HEATER | 2ND FLOOR MEZZANINE | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-GUH-10 | GAS UNIT HEATER | 2ND FLOOR MEZZANINE | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-GUH-11 | GAS UNIT HEATER | 2ND FLOOR MEZZANINE | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-GUH-12 | GAS UNIT HEATER | 2ND FLOOR MEZZANINE | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-IRH-1 | INFRARED HEATER | 1ST FLOOR EAST HIGH BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-IRH-2 | INFRARED HEATER | 1ST FLOOR EAST HIGH BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-IRH-3 | INFRARED HEATER | 1ST FLOOR EAST HIGH BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-IRH-4 | INFRARED HEATER | 1ST FLOOR EAST HIGH BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-IRH-5 | INFRARED HEATER | 1ST FLOOR EAST HIGH BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-IRH-6 | INFRARED HEATER | 1ST FLOOR EAST HIGH BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-IRH-7 | INFRARED HEATER | 1ST FLOOR EAST HIGH BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-IRH-8 | INFRARED HEATER | 1ST FLOOR WEST LOW BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-IRH-9 | INFRARED HEATER | 1ST FLOOR WEST LOW BAY | NFPC | YES | YES | GAS FIRED TYPE | |||
| 592 | 592-MAU-1 | SPLIT UNIT | LOW ROOF WEST SIDE | NFPC | YES | YES | ||||
| 592 | 592-MAU-2 | SPLIT UNIT | LOW ROOF WEST SIDE | NFPC | YES | YES | ||||
| 712 | 712-NGB-1 | STEAM BOILER | WEIL-MCLAIN - M/N LGB-5 - S/N ,CP7633234 | BASEMENT MECHANICAL ROOM | NFPC | BTU =421,000 | ASSET P000484 | |||
| 712 | 712-NGB-2 | STEAM BOILER | WEIL-MCLAIN - M/N LGB-5 S/N 5433004 | BASEMENT MECHANICAL ROOM | NFPC | BTU= 421,000 | ASSET P000485 | |||
| 712 | 712-CPR-1 | CONDENSATE PUMPS & RECEIVER | BELL & GOSSET - M/N 62CSM - S/N Q98J46-SA0771993-015 1 | BASEMENT MECHANICAL ROOM | NFPC | TWO PUMPS | ||||
| 712 | Water Treatment System (Water softener and Chem. feed pump) | CLACK - M/N TT56MSXF2T - S/N 4796640-20, PULSATRON - M/N LB564SA-PTC1 - S/N 05/16.709015 | BASEMENT MECHANICAL ROOM | NFPC | for 2 boilers | ASSET P0001667 & P0001665 | ||||
| *1029 | 1029-ARU-1 | AIR ROTATION UNIT | POWRMATIC TE-51 | NORTHWEST (INSIDE Building) | NFPC | YES | YES | GAS FIRED TYPE | ||
| *1029 | 1029-ARU-1-CC-1 | COOLING COIL FOR ARU-1 | POWRMATIC | NORTHWEST (INSIDE Building) | NFPC | YES | ||||
| *1029 | 1029-ARU-2 | AIR ROTATION UNIT | POWRMATIC -TE-51 | NORTHEAST (INSIDE Building)) | NFPC | YES | YES | GAS FIRED TYPE | ||
| *1029 | 1029-ARU-3 | AIR ROTATION UNIT | POWRMATIC - TE-41HC | NORTHSIDE WESTEND (OUTSIDE) | NFPC | YES | ||||
| *1029 | 1029-ARU-4 | AIR ROTATION UNIT | POWRMATIC-TE-31HC | NORTHSIDE WESTEND (OUTSIDE) | NFPC | YES | ||||
| *1029 | 1029-ARU-5 | AIR ROTATION UNIT | POWRMATIC-TE-31HC | NORTHSIDE WESTEND (OUTSIDE) | NFPC | YES | ||||
| *1029 | 1029-ARU-6 | AIR ROTATION UNIT | POWRMATIC-TE-31HC | NORTHSIDE WESTEND (OUTSIDE) | NFPC | YES | ||||
| *1029 | 1029-CU-1 | CONDENSER UNIT | YORK | NORTHSIDE WESTEND (OUTSIDE) | NFPC | YES | ||||
| *1029 | 1029-CU-2 | CONDENSER UNIT | YORK | NORTHSIDE EASTEND (OUTSIDE) | NFPC | YES | ||||
| *1029 | 1029-CU-3 | CONDENSER UNIT | YORK | NORTHSIDE WESTEND (OUTSIDE) | NFPC | YES | ||||
| *1029 | 1029-CU-4 | CONDENSER UNIT | YORK | NORTHSIDE WESTEND (OUTSIDE) | NFPC | YES | ||||
| *1029 | 1029-CU-5 | CONDENSER UNIT | YORK | NORTHSIDE CENTER (OUTSIDE) | NFPC | YES | ||||
| *1029 | 1029-CU-6 | CONDENSER UNIT | YORK | NORTHSIDE CENTER (OUTSIDE) | NFPC | YES | ||||
| *1029 | 1029-AHU-1 | PACKAGE UNIT | YORK | NORTHSIDE EASTEND (OUTSIDE) | NFPC | YES | ||||
| *1029 | 1029-MAU-1 | MAKE-UP AIR UNIT | YORK | NORTHSIDE WESTEND (OUTSIDE) | NFPC | YES | ||||
| *1029 | 1029-MAU-2 | MAKE-UP AIR UNIT | YORK | NORTHSIDE WESTEND (OUTSIDE) | NFPC | YES | ||||
| 20/1029 | Pkg-02 | PACKAGE UNIT | TRANE Model# WSC048H3REA00JT | LOWER ROOF (Between Bldg. 20 and 1029) | NFPC | Unit feeds building 20 Office Area East War Room/Production Manager's Office (AA-0052) | ||||
| 20/1029 | Pkg-03 | PACKAGE UNIT | TRANE Model# WCD048C400BC | LOWER ROOF (Between Bldg. 20 and 1029) | NFPC | Unit feeds the Project Room | ||||
| 20/1029 | Pkg.04 | PACKAGE UNIT | CARRIER Model# 50TCQA07A2A6A-0A0A0 | LOWER ROOF (Between Bldg. 20 and 1029) | NFPC | Unit feeds Bathrooms/Tool Room 77 | ||||
| 20/1029 | Pkg-05 | PACKAGE UNIT | TRANE Model# TSC092H4RNA02D0 | LOWER ROOF (Between Bldg. 20 and 1029) | NFPC | Unit feeds the Break/Training Room 78. Unit is 7.5 tons | ||||
| 1081 | *1081-1-1 | AHU | YORK - M/N RDS708BY - S/N 35B0084903 | ROOF | NFPC | A62 | (6) 16X25X2 | ASSET P0002672 | ||
| 1081 | *1081-1-2 | AHU | YORK - M/N RDS708BY - S/N 35B0084703 | ROOF | NFPC | A62 | (6) 16X25X2 | ASSET P0002673 | ||
| 1081 | *1081-1-3 | AHU | YORK - M/N RDS708BY - S/N 35B0084803 | ROOF | NFPC | A62 | (6) 16X25X2 | ASSET P0002674 | ||
| 1081 | 1081-NGB-1 | HOT WATER BOILER (NATURAL GAS) | LOCHINVAR - M/N CHN0992 - S/N G12H00241961 | MECHANICAL ROOM | NFPC | 16X16X1 - Comb. Air Filter | ASSET P0001899 | |||
| 1081 | 1081-NGB-2 | HOT WATER BOILER (NATURAL GAS) | LOCHINVAR - M/N CHN0992 - S/N G12H00241962 | MECHANICAL ROOM | NFPC | 16X16X1 - Comb. Air Filter | ASSET P0001898 | |||
| 1081 | 1081-HWCP-1 | IN-LINE CENTRIFUGAL HOT WATER CEN PUMP | BELL & GOSSET | MECHANICAL ROOM | NFPC | ASSET P0001894 | ||||
| 1081 | 1081-HWCP-2 | IN-LINE CENTRIFUGAL HOT WATER CEN PUMP | BELL & GOSSET | MECHANICAL ROOM | NFPC | ASSET P0001895 | ||||
| 1081 | 1081-HWCP-3 | IN-LINE CENTRIFUGAL HOT WATER CEN PUMP | BELL & GOSSET | MECHANICAL ROOM | NFPC | ASSET P0001896 | ||||
| 1081 | 1081-HWCP-4 | IN-LINE CENTRIFUGAL HOT WATER CEN PUMP | BELL & GOSSET | MECHANICAL ROOM | NFPC | ASSET P0001897 | ||||
| 1081 | HOT WATER LOOP | HOT WATER LOOP | MECHANICAL ROOM | NFPC | GLYCOL | |||||
| * = YEAR ROUND OPERATION |
NFPC B581 EQ LIST
| BLDG | ID NO | DESCRIPTION | MFG MODEL NUMBER | LOCATION | CUSTOMER | BELTS | FILTERS | COOLING | REFRIG. | SERVICE | CAPACITY |
| INSIDE/OUTSIDE (FOR FCU) | |||||||||||
| 581 (OA) | 1FCU-1 | FAN COIL UNIT | MITSUBISHI TPEADA0361AA70A/ACCU1 TRUYA0361KA70NA | IT 104 | NFPC | (1) U41002500 | ONLY | R410A | 36,000 BTU/HR | ||
| 581 (OA) | 1FCU-2 | FAN COIL UNIT | MITSUBISHI TPEADA0301AA70A/ACCU2 TRUZA0301HA70NA | IT 120 | NFPC | (1) U41001500 | R410A | 30,000 BTU/HR | |||
| 581 (OA) | 1FCU-3 | FAN COIL UNIT | MITSUBISHI TPEADA0241AA70A/ACCU3 TRUZA0241HA70NA | IT 120 | NFPC | (1) U41001500 | R410A | 24,000 BTU/HR | |||
| 581 (OA) | 1FCU-4 | FAN COIL UNIT | MITSUBISHI TPKA0A0241KA70A/ACCU4 TRUZA0241HA70NA | IT 126 | NFPC | (2) E22C92100 | R410A | 24,000 BTU/HR | |||
| 581 (OA) | 1FCU-5 | FAN COIL UNIT | MITSUBISHI TPKA0A0241KA70A/ACCU5 TRUYA0241HA70NA | ELEVATOR MACHINE ROOM 101 | NFPC | (2) E22C92100 | ONLY | R410A | 24,000 BTU/HR | ||
| 581 (OA) | 1FCU-6 | FAN COIL UNIT | MITSUBISHI TPKA0A0241KA70A/ACCU6 TRUYA0241HA70NA | IT 212 | NFPC | (2) E22C92100 | ONLY | R410A | 24,000 BTU/HR | ||
| 581 (OA) | 1FCU-7 | FAN COIL UNIT | MITSUBISHI TPKA0A0241KA70A/ACCU7 TRUYA0241HA70NA | ELECTRIC ROOM 213 | NFPC | (2) E22C92100 | ONLY | R410A | 24,000 BTU/HR | ||
| 581 (OA) | 1DOAS-1 | DEDICATED OUTDOOR AIR SYSTEM | HORIZON WSHP OAKE210A4-C1C300GN-00000AF6JL2F45B0B500 | ROOF | NFPC | YES | 200MBH | ||||
| Evaporator | (9) 2"thk MERV 8 (20"H x 18"W) | ||||||||||
| Evaporator | (4) 2"thk MERV 8 (20"H X 25"W) | ||||||||||
| Aux Module 46XX-Return Air | |||||||||||
| Aux Module 46XX-Return Air | |||||||||||
| Aux Module 46XX-Outside Air | |||||||||||
| Aux Module 46XX-Outside Air | |||||||||||
| Inlet | (2) 2"thk MERV 8 (16"H X 25"W) | ||||||||||
| 581 (OA) | 1DOAS-2 | DEDICATED OUTDOOR AIR SYSTEM | HORIZON WSHP OAKE240A4-C1C300JN-00000AF6JL2F45B0B500 | ROOF | NFPC | YES | 230MBH | ||||
| Evaporator | (9) 2"thk MERV 8 (20"H x 18"W) | ||||||||||
| Evaporator | (4) 2"thk MERV 8 (20"H X 25"W) | ||||||||||
| Aux Module 46XX-Return Air | |||||||||||
| Aux Module 46XX-Return Air | |||||||||||
| Aux Module 46XX-Outside Air | |||||||||||
| Aux Module 46XX-Outside Air | |||||||||||
| Inlet | (2) 2"thk MERV 8 (16"H X 25"W) | ||||||||||
| 581 (OA) | 1CCEC-1 | CLOSED CIRCUIT EVAPORATIVE COOLER | Baltimore Air Coil (BAC) VFL-072-420 | ROOF | NFPC | YES | CWS COOLING | ||||
| 581 (OA) | 1EF-1 | EXHAUST FAN | COOK 90SQN17DEC,350 CFM,1635 RPM,1/6 HP | MECHANICAL ROOM 108 | NFPC | MECH RM COOLIN | |||||
| 581 (OA) | 1EF-2 | EXHAUST FAN | COOK 90SQN17DEC,150CFM,1401 RPM,1/6 HP | ELECTRIC ROOM 125 | NFPC | ELECT RM COOLING | |||||
| 581 (OA) | 1EF-3 | EXHAUST FAN | COOK 90SQN17DEC,350 CFM,1635 RPM,1/6 HP | WATER ROOM 127 | NFPC | WATER RM COOLING | |||||
| 581 (OA) | 1EUH-1 | ELECTRIC UNIT HEATER | MODINE HER30C 3301 | ELECTRIC ROOM 125 | NFPC | 10,200 BTU/HR | |||||
| 581 (OA) | 1CUH-1 | CABINET UNIT HEATER (HYDRONIC) | TRANE FFDB060/Horizontal Cabinet/487 CFM | VESTIBULE 100 | NFPC | Hot Water Heat | |||||
| 581 (OA) | 1CUH-2 | CABINET UNIT HEATER (HYDRONIC) | TRANE FFHB040/Vertical Recessed/318 CFM | STAIR S1 | NFPC | Hot Water Heat | |||||
| 581 (OA) | 1CUH-3 | CABINET UNIT HEATER (HYDRONIC) | TRANE FFBB040/Vertical Cabinet/318 CFM | STAIR S2 | NFPC | Hot Water Heat | |||||
| 581 (OA) | 1CUH-4 | CABINET UNIT HEATER (HYDRONIC) | TRANE FFDB060/Horizontal Cabinet/487 CFM | CORRIDOR C1 | NFPC | Hot Water Heat | |||||
| 581 (OA) | 1UH-1 | UNIT HEATER (HYDRONIC) | VULCAN RADIATOR/MESTEK HV-108A, Serpentine Coil | WATER ROOM 127 | NFPC | Hot Water Heat | |||||
| 581 (OA) | 1UH-2 | UNIT HEATER (HYDRONIC) | VULCAN RADIATOR/MESTEK HV-108A, Serpentine Coil | MECHANICAL ROOM 108 | NFPC | Hot Water Heat | |||||
| HEAT PUMP MAINTENANCE CONSISTS OF INSPECT/REPLACE AIR FILTERS EVERY 3 MONTHS, ENSURE CONDENSATE TRAP IS PRIMED, CHECK WATER QUALITY AND CHECK CONTACTS/RELAYS YEARLY | |||||||||||
| 581 (OA) | 1HP-1 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF01271-03B0BLF01010032000000000A | LOBBY ROOM 102 | NFPC | PLEATED MERV 8 2"THK 15" X 20" | R410A | Rm. 103/103A | 1 TON | ||
| 581 (OA) | 1HP-2 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF01271-03B0BLF01010032000000000A | CORRIDOR C1 | NFPC | PLEATED MERV 8 2"THK 15" X 20" | R410A | Rm. 103 | 1 TON | ||
| 581 (OA) | 1HP-3 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF01271-03B0BLF01010032000000000A | CORRIDOR C1 | NFPC | PLEATED MERV 8 2"THK 15" X 20" | R410A | Rm. 103 | 1 TON | ||
| 581 (OA) | 1HP-4 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF01271-03B0BLF01010032000000000A | CORRIDOR C1 | NFPC | PLEATED MERV 8 2"THK 15" X 20" | R410A | Rm. 103/107 | 1 TON | ||
| 581 (OA) | 1HP-5 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF00971-03B0BLF01010032000000000A | ENGINEERING ROOM 112 | NFPC | PLEATED MERV 8 2"THK 15" X 20" | R410A | Rm. 102/111/113/115 | .75 TON | ||
| 581 (OA) | 1HP-6 | HEAT PUMP (WSHP) | TRANE VSHV VSHE04241--FBOBL-4A | ENGINEERING ROOM 112 | NFPC | PLEATED MERV 8 2"THK 20" X 25", 20" X 30" | R410A | Rm. 112/114 | 42 MBTUH | ||
| 581 (OA) | 1HP-7 | HEAT PUMP (WSHP) | TRANE VSHV VSHE04241--FBOBL-4A | ENGINEERING ROOM 112 | NFPC | PLEATED MERV 8 2"THK 20" X 25", 20" X 30" | R410A | Rm. 112 | 42 MBTUH | ||
| 581 (OA) | 1HP-8 | HEAT PUMP (WSHP) | TRANE VSHV VSHE04241--FBOBL-4A | ENGINEERING ROOM 112 | NFPC | PLEATED MERV 8 2"THK 20" X 25", 20" X 30" | R410A | Rm. 112/118A | 42 MBTUH | ||
| 581 (OA) | 1HP-9 | HEAT PUMP (WSHP) | TRANE VSHV VSHE04241--FBOBL-4A | ENGINEERING ROOM 112 | NFPC | PLEATED MERV 8 2"THK 20" X 25", 20" X 30" | R410A | Rm. 112/118B | 42 MBTUH | ||
| 581 (OA) | 1HP-10 | HEAT PUMP (WSHP) | TRANE VSHV VSHE04241--FBOBL-4A | ENGINEERING ROOM 112 | NFPC | PLEATED MERV 8 2"THK 20" X 25", 20" X 30" | R410A | Rm. 112 | 42 MBTUH | ||
| 581 (OA) | 1HP-11 | HEAT PUMP (WSHP) | TRANE VSHV VSHE02441--FBOBL-4A | ENGINEERING ROOM 112 | NFPC | PLEATED MERV 8 2"THK 16" X 20", 20" X 20" | R410A | Rm. 116/117 | 24 MBTUH | ||
| 581 (OA) | 1HP-12 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF01871-03B0BLF01010032000000000A | ENGINEERING ROOM 112 | NFPC | PLEATED MERV 8 2"THK 18" X 24" | R410A | Rm. 121/122/1123/124 | 1.5 TON | ||
| 581 (OA) | 1HP-13 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF00671-03B0BLF01010032000000000A | ROOM 219 | NFPC | PLEATED MERV 8 2"THK 15" X 20" | R410A | Rm. 200/215/216 | .5 TON | ||
| 581 (OA) | 1HP-14 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF00971-03B0BLF01010032000000000A | RECEPTION ROOM 201 | NFPC | PLEATED MERV 8 2"THK 15" X 20" | R410A | Rm. 202/203 | .75 TON | ||
| 581 (OA) | 1HP-15 | HEAT PUMP (WSHP) | TRANE VSHV VSHE03341--FBOBL-4A | CORRIDOR C2 | NFPC | PLEATED MERV 8 2"THK 16" X 20", 20" X 20" | R410A | Rm. 201/205/206/207/209 | 33 MBTUH | ||
| 581 (OA) | 1HP-16 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF01271-03B0BLF01010032000000000A | RECEPTION ROOM 201 | NFPC | PLEATED MERV 8 2"THK 15" X 20" | R410A | Rm. 204 | 1 TON | ||
| 581 (OA) | 1HP-17 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF01271-03B0BLF01010032000000000A | CORRIDOR C2 | NFPC | PLEATED MERV 8 2"THK 15" X 20" | R410A | Rm. 210 | 1 TON | ||
| 581 (OA) | 1HP-18 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF01871-03B0BLF01010032000000000A | CORRIDOR C2 | NFPC | PLEATED MERV 8 2"THK 18" X 24" | R410A | Rm. 211 | 1.5 TON | ||
| 581 (OA) | 1HP-19 | HEAT PUMP (WSHP) | TRANE VSHV VSHE04241--FBOBL-4A | ROOM 219 | NFPC | PLEATED MERV 8 2"THK 20" X 25", 20" X 30" | R410A | Rm. 219 | 42 MBTUH | ||
| 581 (OA) | 1HP-20 | HEAT PUMP (WSHP) | TRANE VSHV VSHE04241--FBOBL-4A | ROOM 219 | NFPC | PLEATED MERV 8 2"THK 20" X 25", 20" X 30" | R410A | Rm. 219 | 42 MBTUH | ||
| 581 (OA) | 1HP-21 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF01871-03B0BLF01010032000000000A | ROOM 219 | NFPC | PLEATED MERV 8 2"THK 18" X 24" | R410A | Rm. 219 | 1.5 TON | ||
| 581 (OA) | 1HP-22 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF01871-03B0BLF01010032000000000A | WOMENS ROOM 218 | NFPC | PLEATED MERV 8 2"THK 18" X 24" | R410A | Rm. 219 | 1.5 TON | ||
| 581 (OA) | 1HP-23 | HEAT PUMP (WSHP) | TRANE VSHV VSHE03341--FBOBL-4A | ROOM 219 | NFPC | PLEATED MERV 8 2"THK 16" X 20", 20" X 20" | R410A | Rm. 219 | 33 MBTUH | ||
| 581 (OA) | 1HP-24 | HEAT PUMP (WSHP) | TRANE VSHV VSHE03341--FBOBL-4A | ROOM 219 | NFPC | PLEATED MERV 8 2"THK 16" X 20", 20" X 20" | R410A | Rm. 220 | 33 MBTUH | ||
| 581 (OA) | 1HP-25 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF00671-03B0BLF01010032000000000A | WOMENS ROOM 218 | NFPC | PLEATED MERV 8 2"THK 15" X 20" | R410A | Rm. 221/222/223 | .5 TON | ||
| 581 (OA) | 1HP-26 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF00671-03B0BLF01010032000000000A | ROOM 219 | NFPC | PLEATED MERV 8 2"THK 15" X 20" | R410A | Rm. 224/225/226 | .5 TON | ||
| 581 (OA) | 1HP-27 | HEAT PUMP (WSHP) | TRANE EXHV-DXHV EXHF01871-03B0BLF01010032000000000A | ROOM 219 | NFPC | PLEATED MERV 8 2"THK 18" X 24" | R410A | Rm. 227/228/229 | 1.5 TON | ||
| 581 (OA) | 1HP-28 | HEAT PUMP (WSHP) | TRANE VSHV VSHE02441--FBOBL-4A | ROOM 219 | NFPC | PLEATED MERV 8 2"THK 16" X 20", 20" X 20" | R410A | Rm. 230/231 | 24 MBTUH | ||
| 581 (OA) | 1HP-29 | HEAT PUMP (WSHP) | TRANE VSHV VSHE03341--FBOBL-4A | ROOM 219 | NFPC | PLEATED MERV 8 2"THK 16" X 20", 20" X 20" | R410A | Rm. 232/233/234 | 33 MBTUH | ||
| 581 (OA) | 1CWP-1 | CONDENSER WATER PUMP | BELL & GOSSETT E-1510, 2.5AC, 213T,460 Volts | MECHANICAL ROOM 108 | NFPC | ||||||
| 581 (OA) | 1CWP-2 | CONDENSER WATER PUMP | BELL & GOSSETT E-1510, 2.5AC, 213T,460 Volts | MECHANICAL ROOM 108 | NFPC | ||||||
| 581 (OA) | 1FPP-1 | FREEZE PROTECTION PUMP | BELL & GOSSETT BG-104300 Ecocirc XL 20-35, 1/12 HP, 115 Volts | CORRIDOR C2 | NFPC | ||||||
| 581 (OA) | 1FPP-2 | FREEZE PROTECTION PUMP | BELL & GOSSETT BG-104300 Ecocirc XL 20-35, 1/12 HP, 115 Volts | CORRIDOR C2 | NFPC | ||||||
| 581 (OA) | 1FPP-3 | FREEZE PROTECTION PUMP | BELL & GOSSETT BG-104309 Ecocirc XL 65-130, 1 HP, 208-230 Volts | CORRIDOR C2 | NFPC | ||||||
| 581 (OA) | 1HWP-1 | HEATING WATER DISTRIBUTION | BELL & GOSSETT Series e-90 2AB, 1.5 HP, 460 Volts | MECHANICAL ROOM 108 | NFPC | ||||||
| 581 (OA) | 1HWP-2 | HEATING WATER DISTRIBUTION | BELL & GOSSETT Series e-90 2AB, 1.5 HP, 460 Volts | MECHANICAL ROOM 108 | NFPC | ||||||
| 581 (OA) | 1PHWP-2 | HEATING WATER DISTRIBUTION | BELL & GOSSETT PL-55, 2/5 HP, 115 Volts | MECHANICAL ROOM 108 | NFPC | HEATING WATER BOILER CIRC PMP | |||||
| 581 (OA) | 1PHWP-2 | HEATING WATER DISTRIBUTION | BELL & GOSSETT PL-55, 2/5 HP, 115 Volts | MECHANICAL ROOM 108 | NFPC | HEATING WATER BOILER CIRC PMP | |||||
| 581 (OA) | 1B-1 | BOILER 1 | TRINITY Tft201, DOE Heating Cap 185MBH | MECHANICAL ROOM 108 | NFPC | Boiler-Hot Water, Condensate Water | |||||
| 581 (OA) | 1B-2 | BOILER 2 | TRINITY Tft201, DOE Heating Cap 185MBH | MECHANICAL ROOM 108 | NFPC | Boiler-Hot Water, Condensate Water | |||||
| 581 (OA) | GF-1 | PACKAGED GLYCOL FEEDER | WESSELS GMP-13050, PN: 07101052, 50 gal. | MECHANICAL ROOM 108 | NFPC | Condenser Water | |||||
| 581 (OA) | 1VAV-1 | VARIABLE AIR VOLUME BOX | TRANE VCCF06/6" inlet/375cfm | TRAINING ROOM 103 | NFPC | Dedicated Outdoor Air System (DOAS) | |||||
| 581 (OA) | 1VAV-2 | VARIABLE AIR VOLUME BOX | TRANE VCCF06/6" inlet/375cfm | TRAINING ROOM 103 | NFPC | Dedicated Outdoor Air System (DOAS) | |||||
| 581 (OA) | 1VAV-3 | VARIABLE AIR VOLUME BOX | TRANE VCCF06/6" inlet/375cfm | TRAINING ROOM 103 | NFPC | Dedicated Outdoor Air System (DOAS) | |||||
| 581 (OA) | 1VAV-4 | VARIABLE AIR VOLUME BOX | TRANE VCCF06/6" inlet/375cfm | TRAINING ROOM 103 | NFPC | Dedicated Outdoor Air System (DOAS) | |||||
| 581 (OA) | 1VAV-5 | VARIABLE AIR VOLUME BOX | TRANE VCCF14/14" inlet/2320cfm | 1st Floor Offices | NFPC | Dedicated Outdoor Air System (DOAS) | |||||
| 581 (OA) | 1VAV-6 | VARIABLE AIR VOLUME BOX | TRANE VCCF05/5" inlet/315cfm | 2nd Floor Offices | NFPC | Dedicated Outdoor Air System (DOAS) | |||||
| 581 (OA) | 1VAV-7 | VARIABLE AIR VOLUME BOX | TRANE VCCF08/8" inlet/570cfm | CONFERENCE ROOM 210 | NFPC | Dedicated Outdoor Air System (DOAS) | |||||
| 581 (OA) | 1VAV-8 | VARIABLE AIR VOLUME BOX | TRANE VCCF10/10" inlet/900cfm | BREAK ROOM 211 | NFPC | Dedicated Outdoor Air System (DOAS) | |||||
| 581 (OA) | 1VAV-9 | VARIABLE AIR VOLUME BOX | TRANE VCCF14/14" inlet/2035cfm | 2nd floor Offices | NFPC | Dedicated Outdoor Air System (DOAS) | |||||
| 581 (OA) | 1VAV-10 | VARIABLE AIR VOLUME BOX | TRANE VCCF04/4" inlet/ 180 cfm | CONFERENCE ROOM 116 | NFPC | Dedicated Outdoor Air System (DOAS) | |||||
| 581 (OA) | 1VAV-11 | VARIABLE AIR VOLUME BOX | TRANE VCCF05/5" inlet/250cfm | CONFERENCE ROOM 207 | NFPC | Dedicated Outdoor Air System (DOAS) | |||||
| 581 (OA) | 1VAV-12 | VARIABLE AIR VOLUME BOX | TRANE VCCF04/4" inlet/180cfm | CONFERENCE ROOM 202 | NFPC | Dedicated Outdoor Air System (DOAS) | |||||
| 581 (OA) | 1UV-1 | ULTRAVIOLET DISINFECTION | GLASCO UV GUV-SHIELD-50-MAN, 50gpm, 160 Watts | MECHANICAL ROOM 108 | NFPC | ||||||
| 581 (OA) | CHEMICAL SHOT FEEDER | NEPTUNE DBF-5HP/5 GALLONS | MECHANICAL ROOM 108 | NFPC | |||||||
| 581 (OA) | Condensate Neutralizer | NEUTRA-SAFE CN4-2000 (Recharge Kit# 200RCK) | MECHANICAL ROOM 108 | NFPC | BOILER 1B-1 CONDENSATE | ||||||
| 581 (OA) | Condensate Neutralizer | NEUTRA-SAFE CN4-2000 (Recharge Kit# 200RCK) | MECHANICAL ROOM 108 | NFPC | BOILER 1B-2 CONDENSATE | ||||||
| 581 (OA) | 1HX-1 | Heat Exchanger-Gasketed Plate | BELL & GOSSETT Model P07, PN: BY5442 | MECHANICAL ROOM 108 | NFPC | Boiler-Hot Water, Condensate Water | |||||
| 581 (OA) | 1ET-1 | Expansion Tank | BELL & GOSSETT PTA-12, PN: 1BN052LF | MECHANICAL ROOM 108 | NFPC | Condenser Water | |||||
| 581 (OA) | 1ET-2 | Expansion Tank | BELL & GOSSETT PTA-12, PN: 1BN052LF | MECHANICAL ROOM 108 | NFPC | Heating Water | |||||
| 581 (OA) | 1AS-1 | Air Separator | XXX-XXX | MECHANICAL ROOM 108 | NFPC | Condenser Water | |||||
| 581 (OA) | 1AS-2 | Air Separator | XXX-XXX | MECHANICAL ROOM 108 | NFPC | Heating Water | |||||
| 581 (OA) | XXXX | Flex Connector | METRAFLEX SE10A10A02500090 (Pipe Size - 2.5") | ROOF | NFPC | 1DOAS-1 & 2 Flexible Connector | |||||
| 581 (OA) | XXXX | Flex Connector | METRAFLEX SE10A10A04000090 (Pipe Size - 4") | ROOF | NFPC | 1CCEC-1 Flexible Connector | |||||
| 581 (OA) | XXXX | Flex Connector | METRAFLEX SE10A10A03000090 (Pipe Size - 3") | ROOF | NFPC | 1CCEC-1 Flexible Connector | |||||
| 581 (OA) | XXXX | Flex Connector | METRAFLEX SE10A10A02000090 (Pipe Size - 2") | ROOF | NFPC | 1CCEC-1 Flexible Connector | |||||
| 581 (OA) | XXXX | Flex Connector | METRAFLEX SE10A57A05040160 (Pipe Size 5" x 4") | MECHANICAL ROOM 108 | NFPC | 1CWP-1 & 2 Flexible Connector | |||||
| 581 (OA) | XXXX | Flex Connector | METRAFLEX SE10A57A05250160 (Pipe Size 5" x 2.5") | MECHANICAL ROOM 108 | NFPC | 1CWP-1 & 2 Flexible Connector | |||||
| 581 (OA) | Condensate Pump | Diversitech CP-22 | VARIOUS | NFPC | |||||||
| 581 (OA) | 1PSS-1 | Hydocyclone Separator Package Recovery | Puroflex PF-61-015 | B581 Roof | NFPC | Cooling Tower Solids Separator | |||||
| Solids Seperator Bag | BAG-7X17-10M-II | NFPC | |||||||||
| CONTROL VALVES | |||||||||||
| 581 (OA) | V-1 | 1B-1 Isolation | Belimo G240S-N/NFBUP-S-X1/Globe-1.5"Ø | Rm 108 (Mechanical) | NFPC | Primary HWS | |||||
| 581 (OA) | V-2 | 1B-2 Isolation | Belimo G240S-N/NFBUP-S-X1/Globe-1.5"Ø | Rm 108 (Mechanical) | NFPC | Primary HWS | |||||
| 581 (OA) | V-3 | 1HX-1 HWR | Belimo G240S-N/NFBUP-S-X1/Globe-1.5"Ø | Rm 108 (Mechanical) | NFPC | HWR Isolation | |||||
| 581 (OA) | V-4 | 1HX-1 CWR | Belimo F6125HD/PKRXUP-MFTL20/Bfly-5"Ø | Rm 108 (Mechanical) | NFPC | CWR Isolation | |||||
| 581 (OA) | V-5 | CCEC-1/1HX-1 CWR DIVERTING | Belimo F7125HD/PKRXUP-MFTL21/Bfly-5"Ø | Rm 108 (Mechanical) | NFPC | CWR Diverting | |||||
| 581 (OA) | V-6 | CW Bypass | Belimo B248/AFRB24-SR/Ball-2"Ø | Rm220 (Admin) | NFPC | CW Bypass | |||||
| 581 (OA) | V-7 | HW Bypass | Belimo G220S/LF24-SRUS/Globe-0.75"Ø | Rm 114 (Office) | NFPC | HW Bypass | |||||
| 581 (OA) | V-8 | 1UV-1 | Belimo B250/AFRX24-MFT-SP-10062/Ball-2"Ø | Rm. 108 (Mechanical) | NFPC | UV Disinfection | |||||
| 581 (OA) | V-9 | 1CCEC-1 | Supplied with CCEC-1 | Roof | NFPC | Make-up Water | |||||
| 581 (OA) | V-10 | 1HX-1 | Belimo G2125C/AFX24-MFT-S-X1-P-10001/Globe-5"Ø | Rm. 108 (Mechanical) | NFPC | CW ByPass | |||||
| 581 (OA) | V-11 to V-39 | Condenser Water Coil | Multiple | NFPC | |||||||
| 581 (OA) | V-40 | 1CUH-1 | Belimo G215S-F/LVB24-SR/Globe-0.5"Ø | Rm. 100 (Vestibule) | NFPC | HW Coil | |||||
| 581 (OA) | V-41 | 1CUH-2 | Belimo G215S-F/LVB24-SR/Globe-0.5"Ø | S-1 Stairs | NFPC | HW Coil | |||||
| 581 (OA) | V-42 | 1CUH-3 | Belimo G215S-F/LVB24-SR/Globe-0.5"Ø | S-2 Stairs | NFPC | HW Coil | |||||
| 581 (OA) | V-43 | 1CUH-4 | Belimo G215S-F/LVB24-SR/Globe-0.5"Ø | C-1 Corridor | NFPC | HW Coil | |||||
| 581 (OA) | V-44 | 1UH-1 | Belimo G215S-F/LVB24-SR/Globe-0.5"Ø | Rm. 127 (Water) | NFPC | HW Coil | |||||
| 581 (OA) | V-45 | 1UH-2 | Belimo G215S-F/LVB24-SR/Globe-0.5"Ø | Rm. 108( Mechanical) | NFPC | HW Coil | |||||
| 581 (OA) | V-46 | 1DOAS-1 CW Coil | Belimo B249/AFRB24-SR/Ball-2"Ø | Roof | NFPC | Condenser Water Coil | |||||
| 581 (OA) | V-47 | 1DOAS-2 CW Coil | Belimo B249/AFRB24-SR/Ball-2"Ø | Roof | NFPC | Condenser Water Coil | |||||
| 581 (OA) | 1DDC-1 | DDC SYSTEM | Rm. 108 (Mechanical) | NFPC | |||||||
| 1DDC-2 | DDC SYSTEM | Rm. 108 (Mechanical) | NFPC |
NFPC B123 EQ LIST
| BLDG | ID NO | DESCRIPTION | MFG MODEL NUMBER | LOCATION | CUSTOMER | BELTS | FILTERS | COOLING | REFRIG. | SERVICE | CAPACITY |
| 123 (SRM) | 2RTU-1 | ROOF TOP UNIT | AAON RN-031-3-0-EBOA-EHJ:UGME-D0B-DLT-DOC-0TFAHK3-G0-0001000VB | LOW ROOF | NFPC | (8) 2"thk MERV 8 PLEATED (24"H x 24"W) | Maintenance/Parts | ||||
| SUPPLY FANS (2) | |||||||||||
| EXHAUST FANS (2) | |||||||||||
| SUPPLY ENERGY RECOVERY WHEEL (2) | |||||||||||
| EXHAUST ENERGY RECOVERY WHEEL (2) | |||||||||||
| 123 (SRM) | 2RTU-2 | ROOF TOP UNIT | AAON RQ-004-3-V-EA09-000:GEJC-C0B-QKD-D0C-01EAHK2-F0-00A0000VB | LOW ROOF | NFPC | (2) 2"thk MERV 8 PLEATED (22"H x 22"W) | Calibration Lab/Break Room/Admin | ||||
| SUPPLY FANS (1) | (1) 2"thk MERV 8 PLEATED (24"H x 12"W) | ||||||||||
| EXHAUST FANS (1) | (2) 2"thk MERV 8 PLEATED (24"H x 12"W) | ||||||||||
| SUPPLY ENERGY RECOVERY WHEEL | |||||||||||
| EXHAUST ENERGY RECOVERY WHEEL | |||||||||||
| 123 (SRM) | 2HV-1 | HEATING & VENTILATING UNIT | TRANE CSAA025UB/ | LOW ROOF | NFPC | YES | (18) 2"thk MERV 8 (16"x 25") | Receiving/Inventory (HEAT ONLY) | 14250 CFM | ||
| 123 (SRM) | 2HV-2 | HEATING & VENTILATING UNIT | TRANE CSAA025UB/ | LOW ROOF | NFPC | YES | (18) 2"thk MERV 8 (16"x 25") | Receiving/Inventory (HEAT ONLY) | 14250 CFM | ||
| 123 (SRM) | 2FCU-1 | DUCTLESS SPLIT SYSTEM | MITSUBISHI PKA-A24KA7/PUY-A24NHA7 | IT ROOM 111 | NFPC | (2) (17 5/8" x 18 1/8"), P/N- E12 C92 100 | IT ROOM 111 | ||||
| 123 (SRM) | 2ACCU-1 | DUCTLESS SPLIT SYSTEM | LOW ROOF | NFPC | R410A | 24 MBH | |||||
| 123 (SRM) | 2FCU-2 | DUCTLESS SPLIT SYSTEM | MITSUBISHI PKA-A18HA7/PUY-A18NKA7 | IT ROOM 114 | NFPC | (1) (15-5/8" x 13"), P/N-R01 E36 500, (1) (13'' x 18"), P/N R01 E37 500 | IT ROOM 114 | ||||
| 123 (SRM) | 2ACCU-2 | DUCTLESS SPLIT SYSTEM | IT ROOM 114 | NFPC | R410A | 18 MBH | |||||
| 123 (SRM) | 2FCU-3 | DUCTLESS SPLIT SYSTEM | MITSUBISHI PLA-A12EA7/PUZ-A12NHA7 | OFFICE ROOM 113 | NFPC | (1) 65mm thk (510 mm x 510 mm), P/N- PAC-SH59K-E | OFFICE ROOM 113 | ||||
| 123 (SRM) | 2HP-1 | DUCTLESS SPLIT SYSTEM | OFFICE ROOM 113 | NFPC | air cooled | R410A | OFFICE ROOM 113 | 12 MBH | |||
| 123 (SRM) | 2CUH-1 | CABINET UNIT HEATER | MODINE CW00208ALLL110P00/8129 Btus/252 CFM/115 V | VESTIBULE 131 | NFPC | ||||||
| 123 (SRM) | 2EUH-1 | ELECTRIC UNIT HEATER | HEATREX HX-936U02000UW-D1T1/936 Series/2000W/480V | ELECTRIC ROOM 110 | NFPC | ||||||
| 123 (SRM) | 2EUH-2 | ELECTRIC UNIT HEATER | HEATREX HX-936U02000UW-D1T1/936 Series/2000W/480V | ELECTRIC ROOM 115 | NFPC | ||||||
| 123 (SRM) | 2UH-1 | HOT WATER UNIT HEATER | VULCAN HV-108A/6418 BTUS/245 CFM/115 Volts | COMPRESSOR ROOM 108 | NFPC | ||||||
| 123 (SRM) | 2UH-2 | HOT WATER UNIT HEATER | VULCAN HV-108A/5435 BTUS/210 CFM/115 Volts | FIRE PUMP ROOM 107 | NFPC | ||||||
| 123 (SRM) | 2UH-3 | HOT WATER UNIT HEATER | VULCAN HV-18/9372 BTUS/350 CFM/115 Volts | CORRIDOR 122 | NFPC | ||||||
| 123 (SRM) | 2UH-4 | HOT WATER UNIT HEATER | VULCAN HV-36/16366 BTUS/480 CFM/115 Volts | LOADING DOCK 120 | NFPC | ||||||
| 123 (SRM) | 2UH-5 | HOT WATER UNIT HEATER | VULCAN HV-36/16366 BTUS/480 CFM/115 Volts | LOADING DOCK 120 | NFPC | ||||||
| 123 (SRM) | 2UH-6 | HOT WATER UNIT HEATER | VULCAN HV-108A/6418 BTUS/245 CFM/115 Volts | MECHANICAL PENTHOUSE 126 | NFPC | ||||||
| 123 (SRM) | 2AC-1 | OVERHEAD AIR CURTAIN | MARS WMH168-3UH-TS | LOADING DOCK 120 | NFPC | Heated Loading Dock Area | |||||
| 123 (SRM) | 2B-1 | BOILER NATURAL GAS | NTI-Boilers Trinity Tft-399/380 MBH | MECHANICAL PENTHOUSE 126 | NFPC | ||||||
| 123 (SRM) | 2B-2 | BOILER NATURAL GAS | NTI-Boilers Trinity Tft-399/380 MBH | MECHANICAL PENTHOUSE 126 | NFPC | ||||||
| 123 (SRM) | 2B-3 | BOILER NATURAL GAS | NTI-Boilers Trinity Tft-399/380 MBH | MECHANICAL PENTHOUSE 126 | NFPC | ||||||
| 123 (SRM) | 2DF-1 | DESTRATIFICATION FAN | Arius LLC A-60-P4-STD-120-X/115 Volts | MAINTENANCE & PARTS 118 | NFPC | ||||||
| 123 (SRM) | 2DF-2 | DESTRATIFICATION FAN | Arius LLC A-60-P4-STD-120-X/115 Volts | MAINTENANCE & PARTS 118 | NFPC | ||||||
| 123 (SRM) | 2DF-3 | DESTRATIFICATION FAN | Arius LLC A-60-P4-STD-120-X/115 Volts | RECEIVING 116 | NFPC | ||||||
| 123 (SRM) | 2DF-4 | DESTRATIFICATION FAN | Arius LLC A-60-P4-STD-120-X/115 Volts | RECEIVING 116 | NFPC | ||||||
| 123 (SRM) | 2DF-5 | DESTRATIFICATION FAN | Arius LLC A-60-P4-STD-120-X/115 Volts | INVENTORY 119 | NFPC | ||||||
| 123 (SRM) | 2DF-6 | DESTRATIFICATION FAN | Arius LLC A-60-P4-STD-120-X/115 Volts | INVENTORY 119 | NFPC | ||||||
| 123 (SRM) | 2DF-7 | DESTRATIFICATION FAN | Arius LLC A-60-P4-STD-120-X/115 Volts | INVENTORY 119 | NFPC | ||||||
| 123 (SRM) | 2DF-8 | DESTRATIFICATION FAN | Arius LLC A-60-P4-STD-120-X/115 Volts | INVENTORY 119 | NFPC | ||||||
| 123 (SRM) | 2DF-9 | DESTRATIFICATION FAN | Arius LLC A-60-P4-STD-120-X/115 Volts | INVENTORY 119 | NFPC | ||||||
| 123 (SRM) | 2EF-1 | ROOF TOP EXHAUST FAN | COOK ACRUD-EC/100R17DEC/475 CFM | LOW ROOF | NFPC | ELECTRIC ROOM 110 | |||||
| 123 (SRM) | 2EF-2 | ROOF TOP EXHAUST FAN | COOK ACRUD-VF/150R17D(VF)/1800 CFM | LOW ROOF | NFPC | COMPRESSOR ROOM 108 | |||||
| 123 (SRM) | 2EF-3 | ROOF TOP EXHAUST FAN | COOK ACRUD-EC/70R17DEC/250CFM | LOW ROOF | NFPC | FIRE PUMP ROOM 107 | |||||
| 123 (SRM) | 2EF-4 | ROOF TOP EXHAUST FAN | COOK ACRUD-EC/90R17DEC/300CFM | ELECTRIC ROOM 115 | NFPC | ||||||
| 123 (SRM) | 2EF-5 | SIDEWALL PROPELLER FAN | COOK AWD/42A8DB/14000CFM | FLATBED AREA 117 | NFPC | ||||||
| 123 (SRM) | 2EF-6 | SIDEWALL PROPELLER FAN | COOK AWD/42A8DB/14000CFM | FLATBED AREA 117 | NFPC | ||||||
| 123 (SRM) | 2EF-7 | SIDEWALL PROPELLER FAN | COOK XWD-EC/12XW26D17EC/440CFM | MECHANICAL PENTHOUSE 126 | NFPC | ||||||
| 123 (SRM) | 2FPP-1 | FREEZE PROTECTION | XXXX/In Line ECM | CAL LAB 112 | NFPC | 2HV-1 | |||||
| 123 (SRM) | 2FPP-2 | FREEZE PROTECTION | XXXX/In Line ECM | CAL LAB 112 | NFPC | 2RTU-1 | |||||
| 123 (SRM) | 2FPP-3 | FREEZE PROTECTION | XXXX/In Line ECM | BREAK ROOM 101 | NFPC | 2HV-2 | |||||
| 123 (SRM) | 2FPP-4 | FREEZE PROTECTION | XXXX/In Line ECM | COMPRESSOR ROOM 108 | NFPC | 2HC-1 | |||||
| 123 (SRM) | 2P-1 | CONDENSER WATER PUMP | BELL & GOSSETT e90 C322485-01822 | MECHANICAL PENTHOUSE 126 | NFPC | BOILER 2B-1 | |||||
| 123 (SRM) | 2P-2 | CONDENSER WATER PUMP | BELL & GOSSETT e90 C322485-02822 | MECHANICAL PENTHOUSE 126 | NFPC | BOILER 2B-2 | |||||
| 123 (SRM) | 2P-3 | CONDENSER WATER PUMP | BELL & GOSSETT e90 C322485-03822 | MECHANICAL PENTHOUSE 126 | NFPC | BOILER 2B-3 | |||||
| 123 (SRM) | 2P-4 | HEATING WATER PUMP | BELL & GOSSETT e9051S/PN: 179510LF | MECHANICAL PENTHOUSE 126 | NFPC | ||||||
| 123 (SRM) | 2P-5 | HEATING WATER PUMP | BELL & GOSSETT e9051S/PN: 179510LF | MECHANICAL PENTHOUSE 126 | NFPC | ||||||
| 123 (SRM) | 2HC-1 | HEATING COIL (HYDRONIC DUCT HEATER) | TOZOUR TRANE DT0B12014G0BA110BABA00 | COMPRESSOR ROOM 108 | NFPC | Calibration Lab/Break Room/Admin | |||||
| 123 (SRM) | XXX | Chemical Shot Feeder | NEPTUNE DBF-5HP/5 gallons | MECHANICAL PENTHOUSE 126 | NFPC | Hot Water Service | |||||
| 123 (SRM) | 2P-4 VFD | VFD FOR PUMP | BARDAC E3-110070-1012-01/0.5 HP | MECHANICAL PENTHOUSE 126 | NFPC | ||||||
| 123 (SRM) | 2P-5 VFD | VFD FOR PUMP | BARDAC E3-110070-1012-01/0.5 HP | MECHANICAL PENTHOUSE 126 | NFPC | ||||||
| CONTROL VALVES | |||||||||||
| 123 (SRM) | V-1 | 2B-1 | BELIMO G240S-N/NFBUP-S-X1/Globe-1.5"Ø | MECHANICAL PENTHOUSE 126 | NFPC | Primary HWS | |||||
| 123 (SRM) | V-2 | 2B-2 | BELIMO G240S-N/NFBUP-S-X1/Globe-1.5"Ø | MECHANICAL PENTHOUSE 126 | NFPC | Primary HWS | |||||
| 123 (SRM) | V-3 | 2B-3 | BELIMO G240S-N/NFBUP-S-X1/Globe-1.5"Ø | MECHANICAL PENTHOUSE 126 | NFPC | Primary HWS | |||||
| 123 (SRM) | V-4 | HW BYPAS | BELIMO G225S-K/LF24-SR-US/Globe-1.0"Ø | CORRIDOR 123 | NFPC | Secondary HWS | |||||
| 123 (SRM) | V-5 | 2HV-1 | BELIMO G225S-L/LF24-MFT-S-US-P-10001/Globe-1.0"Ø | CAL LAB 112 | NFPC | HW Coil | |||||
| 123 (SRM) | V-6 | 2HV-2 | BELIMO G225S-L/LF24-MFT-S-US-P-10001/Globe-1.0"Ø | BREAK ROOM 101 | NFPC | HW Coil | |||||
| 123 (SRM) | V-7 | 2RTU-1 | BELIMO G225S-K/LF24-SR-US/Globe-1.0"Ø | CAL LAB 112 | NFPC | HW Coil | |||||
| 123 (SRM) | V-8 | 2HC-1 | BELIMO G215S-F/LF24-SR-US/Globe-1.0"Ø | COMPRESSOR ROOM 108 | NFPC | HW Coil | |||||
| 123 (SRM) | V-9 | 2UH-1 | BELIMO G215S-C/LB24-SR/Globe-0.50"Ø | COMPRESSOR ROOM 108 | NFPC | HW Coil | |||||
| 123 (SRM) | V-10 | 2UH-2 | BELIMO G215S-C/LB24-SR/Globe-0.50"Ø | JANITOR ROOM 105 | NFPC | HW Coil | |||||
| 123 (SRM) | V-11 | 2UH-3 | BELIMO G215S-C/LB24-SR/Globe-0.50"Ø | CORRIDOR 122 | NFPC | HW Coil | |||||
| 123 (SRM) | V-12 | 2UH-4 | BELIMO G215S-C/LB24-SR/Globe-0.50"Ø | LOADING DOCK 120 | NFPC | HW Coil | |||||
| 123 (SRM) | V-13 | 2UH-5 | BELIMO G215S-C/LB24-SR/Globe-0.50"Ø | LOADING DOCK 120 | NFPC | HW Coil | |||||
| 123 (SRM) | V-14 | 2UH-6 | BELIMO G215S-C/LB24-SR/Globe-0.50"Ø | MECHANICAL PENTHOUSE 126 | NFPC | HW Coil | |||||
| 123 (SRM) | V-15 | 2CUH-1 | BELIMO G215S-C/LB24-SR/Globe-0.50"Ø | VESTIBULE 131 | NFPC | HW Coil | |||||
| 123 (SRM) | 2ET-1 | Expansion Tank | WESSELS NLA-85/22010085/23 gallons | MECHANICAL PENTHOUSE 126 | NFPC | Heating Water | |||||
| 123 (SRM) | 2AS-1 | Air Separator | BELL & GOSSETT 5360-02N-12-002/R-2N/140 gpm | MECHANICAL PENTHOUSE 126 | NFPC | Heating Water | |||||
| 123 (SRM) | XXXX | Condensate Nuetralizer | NEUTRA-SAFE CN4-600 | MECHANICAL PENTHOUSE 126 | NFPC | Boiler Condensate Neutralizer | |||||
| 123 (SRM) | DDC SYSTEM | SOUTHLAND/RADIUS SYSTEMS | MECHANICAL PENTHOUSE 126 | NFPC | |||||||
| 123 (SRM) | IT ROOM 111 | NFPC | |||||||||
| 123 (SRM) | 2AC-1 | Air Compressor (oil filled, rotary screw) | Atlas Copco GA15 (125psi) | MECHANICAL PENTHOUSE 126 | NFPC |
BUMED EQ LIST
| BLDG.# | I.D.# | DESCRIPTION | MFG - M/N - S/N | LOCATION | CUSTOMER | BELTS | FILTERS | COOLING | REFRIGERANT | NOTES |
| 615 | RTU-1 | 30-TON DX UNIT COOLING W/HOT WATER COIL HEAT | TRANE - M/N SSHLF30ECA59A5CD6L00A0W000000000T008000 - S/N C10E02148 | ROOF, NORTH SIDE | REGION | SF (2) B68 - RF - B66 | (16) 20x20x2 | DX | R-410-A | ASSET P0002690 |
| 615 | RTU-2 | 30-TON DX UNIT COOLING W/HOT WATER COIL HEAT | TRANE - M/N SLHLF304AN36#49D7001ACWE0000000RT0M8000# - S/N C15F03691 | ROOF, SOUTH SIDE | REGION | SF (1) AX63 - RF BX77 | (6) 24X24X4 (2)12X24X4 | DX | R-410-A | ASSET P0002691 |
| 615 | HP-1 | 2-TON CEILING CASSETTE TYPE INDOOR UNIT - EVAPATOR HEAD | PANASONIC - M/N S-26PU2U6 - S/N 3968201025 | ENTRANCE VESTIBULE | REGION | D/D | WASHABLE | DX | R-410-A | ASSET P0002722 |
| 615 | HP-2 | 1.5- TON WALL MOUNTED CASSETTE TYPE INDOOR UNIT- EVAPATOR HEAD | PANASONIC - M/N E18NKUA - S/N N/A | ELEVATOR MACHINERY ROOM | REGION | D/D | WASHABLE | DX | R-410-A | ASSET P0002725 |
| 615 | HP-3 | 2-TON WALL MOUNTED CASSETTE TYPE INDOOR UNIT - EVAPATOR HEAD | PANASONIC - M/N CS-E24NKUA - S/N 2994904232 | COMMUNICATION ROOM | REGION | D/D | WASHABLE | DX | R-410-A | ASSET P0002723 |
| 615 | CU-1 | 2-TON OUTDOOR CONDENSER UNIT | PANASONIC - M/N CU-E24NKUA - S/N N/A | ROOF, SERVES ENTRANCE VESTIBULE | REGION | D/D | DX | R410-A | ASSET P0002688 | |
| 615 | CU-2 | 1.5 TON OUTDOOR CONDENSER UNIT | PANASONIC - M/N CU-E18NKUA - S/N 6657405923 | ROOF, SERVES ELEVATOR MECH. ROOM | REGION | D/D | DX | R410-A | ASSET P0002687 | |
| 615 | CU-3 | 2- TON OUTDOOR CONDENSER UNIT | PANASONIC - M/N CU-E24NKUA - S/N 6657504052 | ROOF, SERVES COMM. ROOM | REGION | D/D | DX | R410-A | ASSET P0002689 | |
| 615 | B-1 | BOILER - #1 (Gas Fired) | WEIL-MCLAIN - M/N 399-CTNG - S/N N/A | MECHANICAL ROOM | REGION | ASSET P0002697 | ||||
| 615 | B-2 | BOILER - #2 (Gas Fired) | WEIL-MCLAIN - M/N 399-CTNG - S/N N/A | MECHANICAL ROOM | REGION | ASSET P0002698 | ||||
| 615 | BP-1 | CIRCULATING PUMP - #1 | WEIL-MCLAIN | MECHANICAL ROOM | REGION | IN LINE BOILER PUMP | ||||
| 615 | BP-2 | CIRCULATING PUMP - #2 | WEIL-MCLAIN | MECHANICAL ROOM | REGION | IN LINE BOILER PUMP | ||||
| 615 | EF-1 | EXHAUST FAN | COOK - M/N 80SQN80SQN-B - S/N 076SF79415-01/0000701 | MECH. ROOM, CEILING | REGION | A32 | ASSET P0002710 | |||
| 615 | EF-2 | EXHAUST FAN | COOK - M/N 150 ACE150C6B - S/N 076SF79415-01/0001901 | ROOF | REGION | A20 | ASSET P0002692 | |||
| 615 | EF-3 | EXHAUST FAN | COOK - M/N 100 CPF 100CPFB - S/N 076SF79415-00/0000701 | ROOF | REGION | YES | ASSET P0002694 | |||
| 615 | EF-4 | EXHAUST FAN | COOK - M/N N/A - S/N N/A | MECH. ROOM, CEILING | REGION | A37 | ASSET P0002711 | |||
| 615 | P-1 | HOT WATER CIRC. PUMP | TACO - M/N 1915E1E1 - S/N N/A | MECH. RM, SERVES SOUTH ZONE RADIANT HEAT | REGION | ASSET P0002703 | ||||
| 615 | P-2 | HOT WATER CIRC. PUMP | TACO - M/N 1915E1E1 - S/N N/A | MECH. RM, SERVES WEST ZONE RADIANT HEAT | REGION | ASSET P0002704 | ||||
| 615 | P-3 | HOT WATER CIRC. PUMP | TACO - M/N 1915E1E1 - S/N N/A | MECH. RM, SERVES NORTH ZONE RADIANT HEAT | REGION | ASSET P0002705 | ||||
| 615 | P-4 | HOT WATER CIRC. PUMP | TACO - M/N 1915E1E1 - S/N N/A | MECH. RM, SERVES EAST ZONE RADIANT HEAT | REGION | ASSET P0002706 | ||||
| 615 | P-5 | HOT WATER CIRC. PUMP | TACO - M/N 1915E1E1 - S/N N/A | MECH. RM, SERVES UNIT HEATERS | REGION | ASSET P0002707 | ||||
| 615 | P-6 | HOT WATER CIRC. PUMP | TACO - M/N 1915E1E1 - S/N N/A | MECH. RM, SERVES RTU-I | REGION | ASSET P0002708 | ||||
| 615 | P-7 | HOT WATER CIRC. PUMP | TACO - M/N 1915E1E1 - S/N N/A | MECH. RM, SERVES RTU-2 | REGION | ASSET P0002709 | ||||
| 615 | HWP-1 | HOT WATER CIRC. PUMP | TACO - M/N KV3007 - S/N N/A | MECH. RM, SERVES PRIMARY LOOP | REGION | ASSET P0002701 | ||||
| 615 | HWP-2 | HOT WATER CIRC. PUMP | TACO - M/N KV3007 - S/N N/A | MECH. RM, SERVES PRIMARY LOOP | REGION | ASSET P0002702 | ||||
| 615 | UH-1 | CABINET UNIT HEATER | VULCAN - M/N RW1120-02 - S/N 01403397 | NORTHEAST SIDE, NEAR EXAM ROOM 106 | REGION | D/D | WASHABLE | ASSET P0002724 | ||
| 615 | UH-2 | CABINET UNIT HEATER | VULCAN - M/N RW1120-02 - S/N 01403397 | VESTIBULE ENTRANCE | REGION | D/D | WASHABLE | ASSET P0002695 | ||
| 615 | UH-3 | UNIT HEATER | QMARK - M/N MUH0381 - S/N N/A | MECHANICAL ROOM | REGION | D/D | WASHABLE | ASSET P0002713 | ||
| 615 | UH-4 | CABINET UNIT HEATER | VULCAN - M/N RW1120-02 - S/N 01403397 | SOUTHWEST CORNER, KITCHEN | REGION | D/D | WASHABLE | ASSET P0002718 | ||
| 615 | UH-5 | CABINET UNIT HEATER | VULCAN - M/N RW1120-02 - S/N 01403397 | 2ND FLOOR ELEVATOR LOBBY | REGION | D/D | WASHABLE | ASSET P0002719 |
WTR TRTMNT GLYC LIST
| COOLING TOWER TREATMENT LIST | RECOMMENDED WATER TREATMENT | |||
| SITE | CLIENT | BUILDING | LOCATION | FREQUENCY |
| NOTES: 1) If the contractor adds biocide to control bacteria, the contractor must select a biocide approved by the Philadelphia Water Department. 2) Water treatment services to include PM on associated injection pumps and water softener systems. | ||||
| PNYA | REGION | 1 | ATTIC / UNIT 1-1-5 | |
| NSA PHILA | REGION-N | 2 | SECTION B-ROOF / UNIT 2B-200 / 200 TON | all year round (52 weeks) |
| NSA PHILA | REGION-N | 2 | SECTION B-ROOF / UNIT 2B-400 / 400 TON | all year round (52 weeks) |
| NSA PHILA | REGION-N | 2 | SECTION C-ROOF / UNIT 2C / 550 TON | all year round (52 weeks) |
| NSA PHILA | DLA | 3 | SECTION C-ROOF / UNIT 3C / 500 TON | seasonal (32 weeks) |
| NSA PHILA | REGION-N | 4 | SECTION B-ROOF / UNIT 4B / 500 TON | seasonal (32 weeks) |
| NSA PHILA | REGION-N | 4 | SECTION D-ROOF / UNIT 4D / 30 TON | seasonal (32 weeks) |
| NSA PHILA | DLA | 6 | SECTION C-ROOF / UNIT 6C / 1000 TON | seasonal (32 weeks) |
| NSA PHILA | REGION-N | 9 | SECTION 'B' ROOF | seasonal (32 weeks) |
| NSA PHILA | REGION-N | 26 | ROOF / UNIT 26 / 200 TON | seasonal (32 weeks) |
| NSA PHILA | DLA | 45 | ROOF/UNIT 45/ CT501-A Asset #P001038 | all year round (52 weeks) |
| CHILLED WATER SYSTEMS TREATMENT LIST | RECOMMENDED WATER TREATMENT | |||
| SITE | CLIENT | BUILDING | LOCATION | FREQUENCY |
| PNYA | REGION | 1 | ATTIC | |
| PNYA | NFPC | 546 | OUTSIDE OF BLDG. 546, EAST SIDE/230-TON UNIT | SEASONAL (7 MONTHS) |
| NSA PHILA | NWSS | 1 | WING 4-MECHANICAL RM / UNIT AC-1400 / 30 TON | monthly (12 months) - DUAL TEMP (2 PIPE SYS) |
| NSA PHILA | NWSS | 1 | WING 2-MECHANICAL RM / UNIT AC-1204 / 30 TON | monthly (12 months) - DUAL TEMP (2 PIPE SYS) |
| NSA PHILA | REGION-N | 2 | SECTION B-MECHANICAL RM / UNIT AC-2-1 / 200 TON | monthly (12 months) - DUAL TEMP (2 PIPE SYS) |
| NSA PHILA | REGION-N | 2 | SECTION B-MECHANICAL RM / UNIT AC-2-2 / 400 TON | monthly (12 months) - DUAL TEMP (2 PIPE SYS) |
| NSA PHILA | REGION-N | 2 | SECTION C-MECHANICAL RM / UNIT AC-2-3 / 550 TON | monthly (12 months) - DUAL TEMP (2 PIPE SYS) |