C-102.pdf
PDF 706 KB Posted
- Solicitation number
- N4008521R1225
About this file
This document contains plans and specifications for a construction project. The project involves site utility work and foundations for the Dry Dock 2 Complex at the Portsmouth Naval Shipyard in Kittery, Maine. The plans show existing utilities including water, sanitary sewer and electrical systems, and propose upgrades such as intercepting and extending the sanitary sewer main, relocating the 6-inch condensate line on Building 240, and installing foundations, stairs and duct banks. Anticipated outages are identified for various utility systems. Special precautions are noted regarding working near the historical Building 240 and underground monitoring wells. The solicitation is for contract N4008521R1225 issued by the Naval Facilities Engineering Command to construct the Dry Dock 2 Complex in accordance with the specifications and plans.
View the file
Other files
Show 40 more
Latest 50 of 131 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JOHN PAUL JONES AVE.
5/1 4/2
1 1
:38 :56
P M
C:
\D
RO
PB
OX
(C
OL
BY
C O
EN
GI
NE
ER
IN
G)
\E
NG
IN
EE
RI
NG
\29 7 P
OR
TS
MO
UT
H
NA
VA
L S
HI
PY
AR
D\
7.1
.00
1 - D
D# 2 C
OM
PL
EX
D
ES
IG
N\
DR
AW
IN
GS
\S
IT
E
PW
\S
HE
ET
S\
C-
2.D W
G
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
CHIEF ENG/ARCH
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D E
P A
R T
M E
N T
O
F
T
H E
A V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
PO
RT
SM
OU
TH
N
AV
AL
S
HI
PY
AR
D
KI
TT
ER
Y, M
E
PU
BL
IC
W
OR
KS
D
EP
AR
TM
EN
T
- M
AI
NE
NA
VA
L S
HI
PY
AR
D
- P
OR
TS
MO
UT
H, N
H
DRAWFORM REVISION: 31 JANUARY 2017
Project Number
02/05/2021
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
BRANCH MANAGER
FIRE PROTECTION
XXXXXX-XXX-XXXX
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
I S
S U
D
R
C
N
S T
R U
C T
I O
N
B
C T
SCALE:
D
D R
Y D
O C
K
C
O M
P
LE
X V
O
LU
M E
: S
IT
E
A N
D F
O U
N D
A
TI
O N
S
MATTHEW MARK RANDALL
IAN BODWELL
JEFF HOYT
PATRICK BAKAJ
LIST OF ANTICIPATED OUTAGES:
C-102
12839043
LDA MJL
FAC-YR-NUM
ZRJ
AS NOTED
DOCKSIDE COMPLEX SITE UTILITY PLANA1
NOTES:
KEY PLAN
D E
P A
R T
M E
T
T
H
A V
Y
A
M E
N D
M E
N T
B
C T
A
M E
N D
M E
N T
B
C T
AutoCAD SHX Text
BOTTOM OF PLATFORM
AutoCAD SHX Text
TOP OF STEPS
AutoCAD SHX Text
BUILDING 344
AutoCAD SHX Text
ENCLOSED STAIRWAY
AutoCAD SHX Text
RAILS
AutoCAD SHX Text
RAILS
AutoCAD SHX Text
RAIL
AutoCAD SHX Text
DC-2909
AutoCAD SHX Text
DC-2908
AutoCAD SHX Text
MC1
AutoCAD SHX Text
AutoCAD SHX Text
MP
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MP
AutoCAD SHX Text
MP
AutoCAD SHX Text
MP
AutoCAD SHX Text
MP
AutoCAD SHX Text 105(R)
AutoCAD SHX Text S
AutoCAD SHX Text
0XY/ACET
AutoCAD SHX Text
0XY/ACET
AutoCAD SHX Text
AIR
AutoCAD SHX Text
SYL
AutoCAD SHX Text
SYL
AutoCAD SHX Text
SYL
AutoCAD SHX Text
MP
AutoCAD SHX Text
MP
AutoCAD SHX Text
MP
AutoCAD SHX Text
CRANE
AutoCAD SHX Text
FOOTING
AutoCAD SHX Text
SHED
AutoCAD SHX Text
METAL STEPS (CRANE ACCESS)
AutoCAD SHX Text
6-19(R) OBSTRUCTED UNABLE TO ACCESS
AutoCAD SHX Text
SYL
AutoCAD SHX Text
ELECTRIC BOX "DANGER HIGH VOLTAGE"
AutoCAD SHX Text F
AutoCAD SHX Text
1" METAL COND. (ELEC & COMM)
AutoCAD SHX Text
COVER
AutoCAD SHX Text
15" INSULATED PIPE
AutoCAD SHX Text
2" METAL COND.
AutoCAD SHX Text
HATCH
AutoCAD SHX Text
TURNSTILE ON DECK
AutoCAD SHX Text
RAILS
AutoCAD SHX Text
RAMP
AutoCAD SHX Text
AutoCAD SHX Text
FF
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
AutoCAD SHX Text
TP 3
AutoCAD SHX Text
TP 2
AutoCAD SHX Text
GG
AutoCAD SHX Text
DD
AutoCAD SHX Text
WV 1331
AutoCAD SHX Text
WV
AutoCAD SHX Text
BB
AutoCAD SHX Text
WV
AutoCAD SHX Text
MW
AutoCAD SHX Text
MW
AutoCAD SHX Text
MW
AutoCAD SHX Text
CO
AutoCAD SHX Text S
AutoCAD SHX Text 6-9
AutoCAD SHX Text (A)
AutoCAD SHX Text (B)
AutoCAD SHX Text 5-26
AutoCAD SHX Text 6-18
AutoCAD SHX Text 6-17B
AutoCAD SHX Text 6-17
AutoCAD SHX Text 6-15
AutoCAD SHX Text 6-10
AutoCAD SHX Text 6-13
AutoCAD SHX Text
6-17A (FORMER CB)
AutoCAD SHX Text
6-14 (FORMER CB)
AutoCAD SHX Text 6-62
AutoCAD SHX Text 6-11
AutoCAD SHX Text 6-12
AutoCAD SHX Text 6-51
AutoCAD SHX Text 6-16
AutoCAD SHX Text (A)
AutoCAD SHX Text (A)
AutoCAD SHX Text (B)
AutoCAD SHX Text (C)
AutoCAD SHX Text (A)
AutoCAD SHX Text (B)
AutoCAD SHX Text (A)
AutoCAD SHX Text
WV 1328 (TM)
AutoCAD SHX Text
WV 1329 (TM)
AutoCAD SHX Text
WV 1332 (TM)
AutoCAD SHX Text
12" VERTICAL STEAM
AutoCAD SHX Text
MW
AutoCAD SHX Text
MW
AutoCAD SHX Text
MW
AutoCAD SHX Text
MW
AutoCAD SHX Text
MW
AutoCAD SHX Text
MW
AutoCAD SHX Text
MW
AutoCAD SHX Text
SUPPORT LEGS FOR BUMPER STOP (TYP. OF 4)
AutoCAD SHX Text
RAILS EMBEDDED IN CONC.
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
DATA CONNECTION TO B.96 (SEE E-101, VOL. 2)
AutoCAD SHX Text
CONSTRUCT NEW RAIL & MATCH INTO EXISTING RAIL
AutoCAD SHX Text
DOCKSIDE COMPLEX
AutoCAD SHX Text B.240
AutoCAD SHX Text
ENCLOSURE 6
AutoCAD SHX Text
CONDENSING UNIT. SEE DETAIL B4 ON C-505, M-102 VOL 2, AND S-501
AutoCAD SHX Text CONSTRUCTION OF FOUNDATION WILL REQUIRE PILES AND GRADE BEAMS IN CLOSE PROXIMITY TO THE EXISTING 8" SANITARY SEWER MAIN. SANITARY SEWER LINE MUST BE MONITORED TO ENSURE THAT CONSTRUCTION DOES NOT DAMAGE THE PIPE AND UNDERGROUND CONDUIT. ANY DAMAGE TO THE PIPE MUST BE FIXED IMMEDIATELY AND REPORTED TO THE CONTRACTING OFFICER. (SEE S-101)
AutoCAD SHX Text
CAST STEEL RAIL WHEEL STOPS (SEE DETAIL ON S-508)
AutoCAD SHX Text APPROXIMATE LIMIT OF PAVEMENT RESTORATION. MATCH EXISTING GRADE ALONG SAWCUT AND EXISTING BUILDINGS, TYP.
AutoCAD SHX Text INTERCEPT EXISTING SANITARY SEWER MAIN, INSTALL MANHOLE SMH 2020 - 2 RIM ELEV: 9.16 INV IN: 1.50 INV OUT: 1.50
AutoCAD SHX Text INTERCEPT EXISTING SANITARY SEWER MAIN, INSTALL MANHOLE SMH 2020 - 1 RIM ELEV: 9.33 INV IN: 1.88 INV OUT: 1.88
AutoCAD SHX Text
EXISTING DRAINAGE INFRASTRUCTURE
AutoCAD SHX Text
HEAT PUMP. SEE DETAIL B3 ON C-505 AND D1 ON S-501 VOL 1, AND M-141 VOL 2.
AutoCAD SHX Text
4 WAY DUCT BANK
AutoCAD SHX Text 6" INSULATED CONDENSATE LINE TO BE RELOCATED UNDERGROUND, TO THE SIDE OF B. 240 AND TIED INTO EXISTING INSULATED CONDENSATE LINE MOUNTED TO B. 240. 6" CONDENSATE LINE TO BE MOUNTED 20 FEET ABOVE EXISTING GRADE, BUILDING ANCHORS MUST NOT BE MADE TO BRICK.
AutoCAD SHX Text
INSTALL ±8' PVC SDR-35 ANDCOUPLERS TO CONNECT EXISTING SEWER PIPE.
AutoCAD SHX Text
1'-10"X4' SECTIONALIZING CABINET (SEE E-101 VOL. 2) WITH 1'X4' CONCRETE PIER.
AutoCAD SHX Text
EXISTING STORM DRAIN TO BE CAPPED
AutoCAD SHX Text
CONDENSING UNIT. SEE DETAIL B2 ON C-505, M-102 VOL 2, AND D1 ON S-501
AutoCAD SHX Text
STEEL STAIRS AND LANDING, SEE S-101 AND S-103 VOL 1.
AutoCAD SHX Text
2'X2' PRECAST CONCRETE PIERS (SEE DETAIL C1 ON C-505)
AutoCAD SHX Text
2-WAY DUCT BANK
AutoCAD SHX Text
TURNSTILE DRAIN. SEE DETAILS A3 AND B3 ON C-507.
AutoCAD SHX Text ROAD: SNOWDEN STREET SNOWDEN STREET WATER: B. 240: : (3) WATER SERVICES ALONG SNOWDEN STREET ON SOUTH SIDE OF BUILDING. NO OUTAGES MAY OCCUR BETWEEN OCTOBER 1 AND MAY 1. SANITARY SEWER: : 8" GRAVITY MAIN BETWEEN SMH 664 AND SMH 103. TEMPORARY BY-PASS PUMPING AND PUMP TRUCKS PROPOSED TO AVOID OUTAGE. 6" SANITARY SERVICE FROM DOCKSIDE COMPLEX TO DRY DOCK #2. SERVICE TO BE PLUGGED TEMPORARILY DURING OUTAGE. ELECTRICAL: NO OUTAGE REQUIRED PROVIDED THAT ENCLOSURE 6 IS NOT CONNECTED TO SLD EXTENSION. OUTAGE REQUIRED FOR CIRCUIT 4-3A, WORK TO OCCUR DURING OFF-HOURS OR OVER THE WEEKEND. STEAM: STEAM CONDENSATE LINE FORMERLY LOCATED AGAINST STEAM CONDENSATE LINE FORMERLY LOCATED AGAINST B. 346 TO BE RELOCATED ON B. 240. ANTICIPATED OUTAGE OF 2 DAYS AND MUST OCCUR BETWEEN MAY 1 AND OCTOBER 1.
AutoCAD SHX Text
DOCKSIDE COMPLEX SITE UTILITY PLAN
AutoCAD SHX Text
AutoCAD SHX Text 10'
AutoCAD SHX Text 20'
AutoCAD SHX Text Scale: 1" = 10'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1"=10'-0"
AutoCAD SHX Text
1. ALL MANHOLE COVERS REQUIRED TO HAVE 4" STAINLESS ALL MANHOLE COVERS REQUIRED TO HAVE 4" STAINLESS WELD IDENTIFICATION NUMBER ON COVER. 2. MONITORING WELLS MUST BE MAINTAINED THROUGHOUT MONITORING WELLS MUST BE MAINTAINED THROUGHOUT CONSTRUCTION AND ANY CHANGES IN GRADE IN THE VICINITY OF A MONITORING WELL MUST BE RECONSTRUCTED PURSUANT TO DETAIL SHOWN ON C-506 3. MONITORING WELLS ARE USED TO PERFORM CONTINUITY MONITORING WELLS ARE USED TO PERFORM CONTINUITY CHECKS OF THE STIFF LEF DERRICK (SLD) FOUNDATION SYSTEM. ALL MONITORING WELLS MUST REMAIN ACCESSIBLE DURING CONSTRUCTION. 4. HYDRANT FLOW TEST: HYDRANT FLOW TEST: DATE: 6/15/2020, 8:21 AM STATIC 74 PSIG (HYDRANT 13) RESIDUAL 70 PSIG FLOW 1,750 GPM (HYDRANT 11) CALCULATED AT 20 PSIG: 7,135 GPM
AutoCAD SHX Text BUILDING 240 HAS BEEN IDENTIFIED AS A HISTORICAL BUILDING, AS SUCH PROTECTIVE MEASURES MUST BE PUT IN PLACE TO ENSURE THAT THE BUILDING IS NOT DAMAGED DURING CONSTRUCTION.
AutoCAD SHX Text Lee D. Allen 9218
AutoCAD SHX Text 03-19-2021
AutoCAD SHX Text
| Sheets and Views |
| C-102 |
File details come from the government source that posted it. Updated .