This document contains an overhead crane clearance worksheet and existing runway conductor configuration sketch for Enclosure 5, along with details of a related federal solicitation. The clearance worksheet provides dimensions and specifications for overhead cranes to be installed at Dry Dock 2 Complex at Portsmouth Naval Shipyard in Kittery, Maine. It includes information on span lengths, hook locations, rail sizes, walkway clearances, voltage requirements, and obstruction details. The configuration sketch shows the layout of existing runway conductors. The solicitation seeks proposals to support work at the Dry Dock 2 Complex and references the attached RFP for additional opportunity details.
View the file
Other files
Show 40 more
Latest 50 of 131 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A:
B:
D:
C:
E:
H:
G:
F:
O:
P:
N:
M:
L:
K:
J:
I:
Q:
R:
S:
T:
U:
Girder A
Walkway
Walkway Cab
CabCab
Cab
No Cab Girder B
(smallest) lbs./yard lbs. max lbs. max
Indicate Compass Directions Note: Indicate desired features and cab locations (if cab operated) on the girder.
Low point of roof truss, lights, sprinkler or other obstructions on the sides
A (Span - Centerline to Centerline of Runway Rails)
Wheel spacing when two cranes are on the same rail and parked bumper to bumper
Eight-Wheel Crane Four-Wheel Crane
R AND V ARE THE WHEEL LOADS USED FOR DESIGN OF RUNWAY GIRDERS,
EXCLUDING IMPACT, SPACE AS INDICATED.
SOURCE FOR DATA (IF AVAILABLE):
Enclosure (5)
OVER HEAD CRANE CLEARANCE WORKSHEET
Pendant Controller
A (Span - Centerline to Centerline of Runway Rails)
PLAN VIEW
Top of Rail
Rail Size Hooks in High Position
Main Hook
Aux. Hook
Operating Floor
ELEVATION / VIEW X-X
Obstruction
Pit Floor ref.
max.
max.
Centerline of HooksWalkway Walkway
NOTE(S):
O
P
V:
6/7
NCC Form 08-001, May 2008 SKETCH No. A - 1
Appendix A daniel.p.mclaughlin1 Sticky Note Accepted set by daniel.p.mclaughlin1 daniel.p.mclaughlin1 Sticky Note Completed set by daniel.p.mclaughlin1 daniel.p.mclaughlin1 Sticky Note Accepted set by daniel.p.mclaughlin1 daniel.p.mclaughlin1 Sticky Note Rejected set by daniel.p.mclaughlin1 daniel.p.mclaughlin1 Sticky Note Accepted set by daniel.p.mclaughlin1 daniel.p.mclaughlin1 Sticky Note Accepted set by daniel.p.mclaughlin1
Ben Townsend Text Box Dimension B is based on the required reach of the crane below the floor level of Enclosure 5.
Dimension D is referenced from the floor level of Enclosure 5.
CC:
Indicate Compass Directions
OVER HEAD CRANE BUILDING WORKSHEET
Crane
Existing Crane Stop (typ. @ 4 places)
Centerline of hooks when crane parks against the stops
Centerline of hooks when crane parks against the stops
Top of Rail
KK - Runway Conductor (Type/Manufacturer)
AA
(Runway Length)
BB
CC
DD
II
HH
JJ
DD:
EE:
FF:
HH:
JJ:
II:
Rail Span (sketch A-1 dimension A)
Voltage:
Current:
Frequency:
Phase:
VAC
AMP
Hz
NOTE(S):
Top of Rail
KK - Runway Conductor (Type/ Manufacturer)
HH
II
JJ
HorizontalVertical
KK:
Trolley
Main Power Disconnect
Main Power Disconnect
Main Power Disconnect
Main Power Disconnect
Main Power Disconnect
Main Power Disconnect
GG
FF Obstruction
GG:
BB:
AA:
EE EE
Indicate the side of the building which has a crane access ladder max.
max.
max.
ref.
PLAN VIEW
CRANE ELECTRIFICATION EXISTING RUNWAY CONDUCTOR CONFIGURATION
7/7
NCC Form 08-001, May 2008 SKETCH No. A - 2
Enclosure (5)
Appendix A
| form1[0]: |
| #subform[5]: |
| #subform[6]: |
| TextField3[4]: 25' - 4" |
| TextField1[10]: 40'-9" |
| TextField1[11]: 29'-9" |
| TextField1[12]: 8' - 4" |
| TextField1[13]: 3' - 11" |
| TextField1[14]: NA |
| TextField1[15]: NA |
| TextField1[16]: 3' - 5" |
| TextField1[17]: NA |
| TextField1[18]: NA |
| TextField1[19]: NA |
| TextField1[20]: NA |
| TextField1[21]: 30 |
| TextField1[22]: 8" |
| TextField1[23]: 6" min. |
| TextField1[24]: 2" min. |
| TextField1[25]: 3' - 8" |
| TextField1[26]: 13,500 |
| TextField1[27]: NA |
| TextField1[28]: NA |
| TextField1[29]: NA |
| TextField1[30]: |
| CheckBox[0]: 1 |
| CheckBox[1]: Off |
| RadioButtonList[0]: 4 |
| DropDownList3[1]: [] |
| DropDownList2[1]: [2] |
| TextField2[1]: Z |
| TextField2[2]: W |
| TextField2[3]: X |
| TextField2[4]: |
| CheckBox[2]: Off |
| CheckBox[3]: Off |
| TextField1[31]: Direction markings are not cardinal markings. Verify Layout with building Contractor |
| TextField1[32]: Hoist lower limit to be set 4' below Enclosure-5 floor. |
| TextField1[33]: NA |
| #subform[7]: |
| #subform[8]: |
| TextField1[34]: 6' - 0" |
| RadioButtonList[1]: 4 |
| DropDownList2[2]: [1] |
| TextField2[5]: Z |
| TextField2[6]: W |
| TextField2[7]: X |
| TextField1[35]: TBD |
| TextField1[36]: NA |
| TextField1[37]: NA |
| TextField1[38]: NA |
| TextField1[39]: NA |
| TextField1[40]: NA |
| TextField1[41]: 480 |
| TextField1[42]: 50 |
| TextField1[43]: 60 |
| TextField1[44]: 3 |
| TextField1[45]: TBD dimensions will be determined by crane contractor. |
| RadioButtonList[2]: Off |
| TextField1[47]: NA |
| TextField1[48]: NA |
| TextField1[49]: 3' - 8" |
| TextField1[50]: 27' - 10" |
| DropDownList3[2]: [W] |
| TextField1[46]: |
| 0: Building directions do not match cardinal directions. |