Q907 SOF DRY COMBAT SUBMERSIBLE OPERATIONS FACILITY FY20
AT JEB LITTLE CREEK Sol. # N4008519F5184
PART 3 - CHAPTER 6 / ESR C10 - Page 1
6. ENGINEERING SYSTEMS REQUIREMENTS
C10 INTERIOR CONSTRUCTION
SYSTEM DESCRIPTION
Interior construction includes interior partitions, interior doors, and fittings.
Provide durable construction appropriate for the building function. Acoustic properties of materials, as well as durability, must be considered during material selection.
GENERAL SYSTEM REQUIREMENTS
Areas of the Project subject to abuse require that "impact resistant" systems be provided. See "Room Requirements" for specific requirements on "Partitions", "Interior Doors", and "Fittings".
C1010 PARTITIONS
Refer to Part 3 Section 5.0, Room Requirements for partition requirements for individual rooms.
Where rooms with different partition requirements adjoin one another, provide a combined wall type that meets the security and durability as well as finish requirements of both spaces.
All interior partitions must be either concrete masonry (type A) or metal stud with impact resistant gypsum board (type B). All corridor walls are to be burnished block up to 4’-8” and painted cmu above. Interior office partitions may be constructed of metal studs with gypsum board on each side. At corridor and exterior walls, provide metal furring channels and gypsum board attached to either concrete or cmu wall.
Concrete mixture must provide an average compressive strength of 3000 PSI (20,680 kPa and meet or exceed American Concrete Institute (ACI) 301/301M.
Provide rated partitions per Part 3 Section 5.0, Room Requirements and Life safety drawings and as required by code. All rated wall assemblies shall be UL listed.
C101001 FIXED PARTITIONS
Provide fixed interior partitions that extend from finish floor to underside of structure above.
Sound-rated partition assemblies must have a minimum Sound Transmission Coefficient (STC as indicated within room requirement sheets.
C101002 DEMOUNTABLE PARTITIONS
Demountable partitions include full height (floor to ceiling) wire mesh partitions. Extend wire mesh partitions meant for security purposes to the structural ceiling, or provide a wire mesh ceiling. Wire mesh to be maximum vertical/horizontal opening dimension must be 2 inches (51 mm). Minimum thickness – 9 gage (3.76 mm). Coordinate finishes with Section C30 Interior Finishes.
C101003 RETRACTABLE PARTITIONS
Not Used.
PART 3 - CHAPTER 6 / ESR C10 - Page 2
C101004 INTERIOR GUARDRAILS AND SCREENS
Not Used.
C101005 INTERIOR WINDOWS
Provide interior windows of aluminum, fixed. Provide each window as a complete factory-assembled unit with glass factory or field installed.
C101006 GLAZED PARTITIONS & STOREFRONTS
Provide glazed storefront system.
C101007 INTERIOR GLAZING
Provide clear glass laminated glass and interior glazing.
At Pool, area provide clear insulated, laminated glass.
C1020 INTERIOR DOORS
C102001 STANDARD INTERIOR DOORS
Refer to Part 3 Section 5.0, Room Requirements for door requirements for individual rooms. Where rooms with different door requirements are connected by a door, provide a door type that meets the security and durability as well as finish requirements of both spaces.
All interior doors must be flush.
All interior doors and frames that are required to meet fire rating must be hollow metal unless indicated on Part 3 Section 5.0, room requirements.
All interior doors must be wood, except where indicated in room requirements. All interior doors must be hollow metal frames.
Provide STC sound rated door assemblies for doors leading into Secured Area(s) listed rooms in the Part 3 Section 5.0,, Room Requirements. Provide a factory tested, insulated, engineered, metal door assembly including door frame, hardware, and seals necessary to achieve the required rating. Install in accordance with manufacturer's instructions.
C102002 GLAZED INTERIOR DOORS
Provide vision glazing in doors where it is required by the “Room Requirements” portion of this RFP, or it is deemed advantageous to be able to see through the door, either for safety of pedestrian traffic, or other functional reason.
C102003 FIRE DOORS
Provide interior fire doors as required per fire assemblies.
PART 3 - CHAPTER 6 / ESR C10 - Page 3
C102004 SLIDING AND FOLDING DOORS
Not Used.
C102005 INTERIOR OVERHEAD DOORS
Provide interior coiling overhead doors where required by Part 3 Section 5.0, Room Requirements.
All overhead doors to be insulated. Doors at pool enclosure to be insulated and include weatherstripping.
All Overhead doors to include motorized operators.
C102006 INTERIOR GATES
Not Used
C102007 INTERIOR DOOR HARDWARE
Provide special door hardware, such as combination locks or card key system at doors indicated in “Room Requirements”.
Provide card key type access units for specialized entries. Provide lithium battery powered, magnetic stripe keycard locksets that are American National Standards Institute/Builders Hardware Manufacturers Association (ANSI/BHMA) A156.2, Series 4000, Grade 1, cylindrical locks, tamper resistant, Underwriters Laboratories (UL) listed with 1 inch (25 mm) throw deadbolt, 3/4-inch (19 mm ) throw latch bolt, auxiliary dead-locking latch, and 2-3/4 inch (68.75 mm) backset.
Provide chrome-plated brass or bronze, or stainless steel hardware finish.
All doors accessing pool area shall have stainless steel hardware to prevent corrosion.
Mother’s room shall be privacy hardware that allows exiting from the room interior without the use of a key. Hardware shall be ABA compliant.
C102090 OTHER INTERIOR SPECIALTY DOORS
Not Used
C102091 OTHER INTERIOR PERSONNEL DOORS
Interior doors accessing pool area shall be aluminum frames and aluminum doors.
C1030 SPECIALTIES
C103001 COMPARTMENTS, CUBICLES, & TOILET PARTITIONS
Provide floor mounted overhead braced HDPE or toilet partitions in all toilet rooms with more than one water closet or urinal. Provide toilet accessories as indicated in Part 3 Section 5.0, “Room Requirements” portion of this RFP. Toilet partitions must be compliant with NFPA 286 “Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth”, Class B
PART 3 - CHAPTER 6 / ESR C10 - Page 4
C103002 TOILET AND BATH ACCESSORIES
Provide toilet and bath accessories. Verify size and types of paper products with Base Janitorial Supply Contractor. All toilet rooms to include paper towel dispensers and electric hand dryers.
Provide brushed stainless steel toilet and bath accessories as indicated in Part 3 Section 5.0, "Room Requirements. Shower curtain rods must be mounted at height to accommodate a standard 72” length shower curtain. Coordinate mounting heights and hardware with wall tile design and grout lines to avoid drilling through tiles.
C103003 MARKER BOARDS AND TACK BOARDS
Provide marker boards and tack boards as indicated in Part 3 Section 5.0, "Room Requirements" portion of this RFP. Boards must have anodized aluminum where indicated in the Room Requirements. Marker boards shall be opaque back-painted glass type and shall attract standard magnets (rare-earth magnets not required) and may be frameless or framed to match the other display boards. Marker boards and tack boards must have tool trays and one set of tools provided for each board. Tack Boards must be natural or colored cork, fabric is not acceptable. Coordinate with building construction to include appropriate blocking or structural support for the installation of marker boards and tack boards.
Marker boards and tack boards are funded as part of the construction contract.
C103004 IDENTIFYING DEVICES
Provide interior room identification signs on each entrance to each interior room. Provide signage to identify each space by room number and name. Signage for general office areas must have changeable room name sections to accommodate personnel and functional changes.
Incorporate all necessary interior signage as part of the architectural drawings. Interior signage is not collateral equipment. Interior signage must demonstrate complete coordination with the facility design, Structural Interior Design (SID) and FF&E submittals. Provide interior directional signage as required for facility wayfinding. Provide an identifying device at each interior and exterior door, as well as emergency and informational signage throughout the facility. Signs must meet Architectural Barriers Act (ABA) Standards requirements. Refer to Unified Facilities (UFC) 3-120-01, Design: Sign Standards, for more information.
C103005 LOCKERS
Provide single-tier high density polyethylene/solid plastic lockers with special bases of three inches.
Lockers must include one coat rod, one shelf and two coat hooks. Provide lockers with standard latching mechanism capable of receiving a standard combination padlock (locks NIC). All lockers shall maximize air circulation.
At locker rooms, provide 36” wide single-tier steel construction and enamel finish lockers with special bases of three inches. Locker frames shall be minimum 16 gauge with flat tops. Lockers must include one coat rod, one shelf, two coat hooks, number plate. Provide lockers with standard latching mechanism capable of receiving a standard combination padlock (locks NIC). All lockers shall maximize air circulation.
Cell Phone Lockers: Provide free-standing, metal construction and enamel finish lockable cell phone lockers. Lockers must be minimum 5” deep Standard A sizes (6-1/2” wide X 5-1/4” high. Lockers shall have a resettable combination and a master key. Locker unit shall have a panel that provides access to all individual lockers.
PART 3 - CHAPTER 6 / ESR C10 - Page 5
Lockers are funded as part of the construction contract.
C103006 SHELVING
Pallet container (PALCON) style industrial shelving rack containers shall be stackable 3 high (8’-0” top shelf height). They shall be accessible via forklift. Each rack shall be deep enough to hold a pallet.
Racks shall be designed to carry heavy pallet loads and anchored and/or laterally braced as determined by the DOR. All pallet container racks must come with steel wire rack shelves/decking.
Ensure the shelving/decking is adequately size for the load.
Provide (4) custom fabricated wet suit drying trees. Each structure is 83” high and constructed of welded 2” square tube steel, with 3-tiers and 4 branches per tier. Each tree is bolted directly to the concrete slab through a welded steel, 12” x 12” base plate.
Provide 8-12” deep wall mounted stainless steel shelf with mop hooks and heavy duty shelving supports for janitorial closets. Locate over the mop/ janitorial sink so mops drain into the sink.
Built-in fixed shelving is funded as part of the construction contract.
Parts Storage- Provide (8) 4’-0” deep X 8’-0” length X 10’-0” tall industrial parts storage shelving.
Each unit shall have minimum 6 shelves with wire decking and required support channels.
Decking to have waterfall edge to provide secure fit. Each shelve to support min. 2,500 LBS.
Calibration- Provide (2) 1’-6” deep X 5’-0” length X 8’-0” tall heavy duty steel shelving. Each unit to have (5) adjustable shelves that have capacity of minimum 1,000 LBS per shelf. Entire shelving unit to have powder coated finish.
Dive Gear Setup- Provide (1) 3’-0” deep X 10’-0” length X 8’-0” tall heavy duty steel shelving.
Each unit to have (4) adjustable shelves that have capacity of minimum 2,000 LBS per shelf.
Entire shelving unit to have powder coated finish.
Dive Air- Provide (1) 3’-0” deep X 10’-0” length X 8’-0” tall heavy duty steel shelving. Each unit to have (4) adjustable shelves that have capacity of minimum 2,000 LBS per shelf. Entire shelving unit to have powder coated finish.
Tool Room- Provide (7) 2’-0” deep X 5’-0” length X 8’-0” tall heavy duty steel shelving. Each unit to have (5) adjustable shelves that have capacity of minimum 1,000 LBS per shelf. Entire shelving unit to have powder coated finish.
C103007 FIRE EXTINGUISHER CABINETS
Not Used.
C103008 COUNTERS
Provide solid acrylic counter tops back and side splashes. Typical splash is 4” high. Splash at sink areas (with upper cabinets) to extend to the underside of the upper cabinets above, the entire length of the counter.
C103009 CABINETS
Provide cabinetry and millwork items with associated accessories. Cabinetry must be Architectural Woodwork Institute (AWI) custom grade and have concealed hinges with adjustable standards for
PART 3 - CHAPTER 6 / ESR C10 - Page 6 shelves. All exposed surfaces must be clad in high pressure plastic laminate. Melamine is not acceptable product for any surface.
Provide specific cabinetry and storage as noted in Part 3, Chapter 5 Room Requirements.
C103010 CASEWORK
Not Used.
C103011 CLOSETS
Not Used.
C103012 FIRESTOPPING SYSTEMS
All firestopping systems shall be performed by one experienced firestop contractor. Experienced firestop contractor is defined as following:
1. FM Research approved in accordance with FM 4991, or
2. Operating as a UL Certified Firestop Contractor, or
3. A contractor completed the manufacturer accredited firestop specialty contractor program.
Certified, licensed or otherwise qualified by the firestopping manufacturer as having the necessary staff, training, and a minimum of 3 years of experience in the installation of manufacturer’s products in accordance with specified requirements. Submit documentation of this experience. A manufacturer’s willingness to sell its firestopping products to the contractor or to an installer engaged by the Contractor does not in itself confer installer qualifications on the buyer. Individual building system subcontractor, such as Mechanical, Electrical, Plumbing, Gypsum wall, etc., is not permitted to install firestopping systems.
A single complete submittal including Shop Drawings, Product Data, UL details must be provided for all firestopping systems throughout entire project.
C103013 SPRAYED FIRE-RESISTIVE MATERIALS
Provide sprayed fire-resistive materials to the building's structural framing components as required by Building Code to prevent structural failure.
C103014 ENTRANCE FLOOR GRILLES AND MATS
Not Used.
C103015 ORNAMENTAL METAL WORK
Not Used.
C103090 OTHER INTERIOR SPECIALTIES
Not Used.
--End of Section--