E-102_Amend 6.pdf
PDF 636 KB Posted
- Attached to
- N4008023R0020 LARGE PROJECTS MULTIPLE AWARD CONSTRUCTION CONTRACT (MACC) Federal contract opportunity
- Solicitation number
- N4008023R0020
About this file
This document contains an electrical site plan and general notes for a construction project at Naval Facilities Engineering Command. Key details include specifications for airfield lighting fixtures to be located no more than 200 feet apart at taxiway sections and 10 feet from concrete edges. It provides instructions for routing site lighting electrical conduit below gate foundations and modifying existing electrical manhole rim elevations to match grade. Directional boring is specified under South Perimeter Road. Roadway flashers and NEMA-4X electrical enclosures for gate motor controllers are also required. The related federal contract opportunity notice provides a solicitation number for a large projects multiple award construction contract through the Department of the Navy Naval Facilities Engineering Command but refers to SAM.gov for full solicitation documents.
View the file
Other files for this federal contract opportunity
Show all 50
N4008023R0020 LARGE PROJECTS MULTIPLE AWARD CONSTRUCTION CONTRACT (MACC) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HH
HH
MH
MH
HH
HH
MH
MH
HH1
FOD CHECK POINT
STOP BAR
9 10
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 06 APRIL 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
W A
S H
IN
G
TO
N
JO
IN
T
BA
SE
A
N D
R
EW
S N
AV
AL
A
IR
F
AC
IL
IT
Y C
AM
P
SP
R
IN
G
S, M
D
POJCH JCH
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
P -3
R E
LO
C
A
TE
H A
ZA
R
D O
U S
C A
R G
O P
A D
A N
D E
O D
P R
O
FI
C
IE
N C
Y R
A N
G E
W
AS
H
IN
G
TO
N N
AV
Y
YA
R
D W
AS
H
IN
G
TO
N
, D C
N40080-15-D-0452
1396650
KEY PLAN
IS
SU
E
FO
R
CO
NS
TR
UC
TI
ON
9/2 6/2
E
LE
C
TR
IC
A
L S
IT
E
P
LA
N
A R
E A
E-102
M
AT
CH
L
IN
E
- S
EE
S
HE
ET
E
-1
M
AT
CH
L
IN
E-
S
EE
S
HE
ET
E
-1
1" = 50'A1 ELECTRICAL SITE PLAN - AREA 2
PLAN
NORTH
GENERAL NOTES
1. ALL EXISTING UNDERGROUND UTILITY LOCATIONS AS SHOWN ON
THESE PLANS ARE APPROXIMATE AND MAY NOT REPRESENT ALL
UNDERGROUND UTILITIES OR SERVICE LINES. SOURCE OF EXISTING
UTILITY MAPPING: UTILITY LOCATIONS ARE BASED ON QUALITY LEVEL
"B" AS DEFINED BY ASCE STANDARD 38-02 "STANDARD GUIDELINE FOR
THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY
DATA". VERIFY EXACT LOCATION, DEPTH, SIZE, AND TYPE OF UTILITIES
SHOWN AND NOTIFYING ENGINEER OF DISCREPANCIES. REPAIR AND
REPATCH AS NEEDED SUBSEQUENT TO ANY DAMAGE TO PROPERTY
OR UTILITIES.
2. CONTACT "MARYLAND MISS UTILITY" AT 1-800-257-7777 PRIOR TO
BEGINNING ANY EXCAVATION OR DEMOLITION.
3. SEE SHEET E-501 FOR SITE LIGHTING FIXTURE SCHEDULE.
4. SEE SHEET E-104 FOR CABLE SCHEDULE.
5. COORDINATE SITE LIGHTING POLE BASE EXACT LOCATION WITH THE
LANDSCAPING DESIGN.
WORK NOTES
1. PROVIDE AIRFIELD LIGHTING FIXTURES AS INDICATED ON PLAN.
ENSURE AIRFIELD LIGHTING FIXTURES ARE LOCATED AT A
DISTANCE NO GREATER THAN 200' FROM EACH OTHER AT STRAIGHT
TAXIWAY SECTIONS. AIRFIELD LIGHTING FIXTURES LOCATED 10'
FROM EDGE OF CONCRETE TAXIWAY.
2. THIS PORTION UNDER PAVED SECTION IS CONCRETE-ENCASED
DUCT BANK. SEE CABLE SCHEDULE ON SHEET E-104 TO DETERMINE
NUMBER OF WAYS. ROUTE SITE LIGHTING ELECTRICAL
CONDUIT/DUCT BANK BELOW GATE FOUNDATION.
3. SEE STRUCTURAL AND CIVIL PLANS FOR DETAILS REGARDING
ELECTRICAL AND TELECOMM STRUCTURES.
4. MODIFY EXISTING ELECTRICAL MANHOLE RIM ELEVATION TO MATCH
PROPOSED GRADE. SEE SHEET E-501, DETAIL M.
5. PROVIDE DIRECTIONAL BORING FOR LOCATIONS UNDERNEATH OF
SOUTH PERIMETER RD. COORDINATE SPECIFIC REQUIREMENTS
WITH BASE.
6. PROVIDE ROADWAY FLASHERS FOR TRAFFIC. SEE DETAIL (FIG. 84D)
ON SHEET E-501.
7. PROVIDE NEMA-4X, STAINLESS STEEL, C-CHANNEL RACK-MOUNTED,
NEMA-4X ENCLOSURE AND CONTROLLERS FOR GATE MOTORS. SEE
DETAIL C3 ON SHEET E-502. PROVIDE CONTROL CABLING PER
MANUFACTURERS INSTRUCTIONS AND RECOMMENDATION.
COORDINATE WITH GATE CONTROLLER VENDOR TO PREVENT
SIMULTANEOUS ENERIGIZATION OF ALTERNATE CIRCUITS.
8. SEE DETAIL A1, SHEET E-504.
9. PROVIDE TYPE 10 HANDHOLE. SEE DETAIL C1 ON SHEET E-503.
10. SEE SHEET E-506 FOR MANHOLE AND HANDHOLE DIAGRAMS.
1 2 3 4
/15 /20
AM
EN
DM
EN
T
File details come from the government source that posted it. Updated .