This document contains storm sewer profile drawings and notes for a construction project. The drawings depict existing and finished grade elevations, stormwater detention areas, and the 10-year high groundwater level for various segments of storm sewer structures. Notes specify a minimum cover of 2 feet for storm sewers and an 18-inch minimum clearance for crossing utilities.

The related federal contract opportunity is a solicitation issued by the Naval Facilities Engineering Command for a Large Projects Multiple Award Construction Contract. Offerors are directed to SAM.gov for full solicitation documents and any amendments under solicitation number N40080-23-R-0020. The solicitation seeks to establish multiple IDIQ contracts for construction projects over $25 million within the NAVFAC area of operations.

View the file

Other files

File Type Posted
23R0020 0013.pdf PDF
23R0020 0012.pdf PDF
0012 - Attachment G - SBSP.docx DOCX document
23R0020 Amendment 0011.pdf PDF
N4008023R0020 Amendment 0010.pdf PDF
ATTACHMENT H - Price Schedule_IGE - BLANK 05082023.pdf PDF
N4008023R0020 Amendment 0009.pdf PDF
N4008023R0020 Amendment 0008.pdf PDF
N4008023R0020 Amendment 0007.pdf PDF
GC-005_Amend 6.pdf PDF
E-501_Amend 6.pdf PDF
CS-102_Amend 6 (2).pdf PDF
Concrete Vault and Water Main additional Site photos (2).pdf PDF
31 23 00.00 20_Amend 6 (2).pdf PDF
E-504_Amend 6.pdf PDF
CU-204_Amend 6 (2).pdf PDF
CS-502_Amend 6 (2).pdf PDF
E-203_Amend 6.pdf PDF
01 17 00_Amend 6 (2).pdf PDF
CT-102_Amend 6 (2).pdf PDF
CD-101_Amend 6 (2).pdf PDF
E-102_Amend 6.pdf PDF
GI-113_Amend 6.pdf PDF
CS-503_Amend 6 (2).pdf PDF
GI-111_Amend 6.pdf PDF
Additional Site Photos (2).pdf PDF
CU-505_Amend 6 (2).pdf PDF
E-500_Amend 6.pdf PDF
01 50 00_Amend 6 (2).pdf PDF
V-101_Amend 6.pdf PDF
CT-501_Amend 6 (2).pdf PDF
CG-403_Amend 6 (2).pdf PDF
CG-121_Amend 6 (2).pdf PDF
Specifications Table of Content_Amend 6.pdf PDF
Propane Tank Information as shown on V-101.pdf PDF
N4008023R0020 Amendment 0006.pdf PDF
CD-102_Amend 6 (2).pdf PDF
GI-112_Amend 6.pdf PDF
32 92 19_Amend 6 (2).pdf PDF
CG-122_Amend 6 (2).pdf PDF
CT-502_Amend 6 (2).pdf PDF
Flashing Beacon Specification and Details Amend 5.pdf PDF
01 14 00_Amend 5.pdf PDF
CG-503_Amend 5.pdf PDF
CG-111_Amend 5.pdf PDF
L-104_Amend 5.pdf PDF
CG-123_Amend 5.pdf PDF
ATTACHMENT H - P-3002 HCP PRICE SCHEDULE-BLANK 041323.pdf PDF
CT-104_Amend 5.pdf PDF
CG-103A_Amend 5.pdf PDF
Show 40 more

Latest 50 of 121 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STORM SEWER STRUCTURE SD50 TO SD85 PROFILE

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00

STORM SEWER STRUCTURE

SD28 TO SD64 PROFILE

0+00 1+00 1+50

STORM SEWER STRUCTURES

SD69 TO SD20 PROFILE

-0+50 0+00 1+00

STORM SEWER STUCTURES

SD48 TO SD21 PROFILE

-0+50 0+00 1+00 STORM SEWER STRUCTURE

SD70 TO SD20 PROFILE

-0+50 0+00 1+00

STORM SEWER STRUCTURE SD27 TO SD79 PROFILE

0+00 1+00 2+00 3+00 4+00 5+00 6+00

STORM SEWER STRUCTURES SD18 TO SD19 PROFILE

9+50 10+00 11+00 12+00 13+0013+50

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O

F

T

H E

A V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DRAWFORM REVISION: 06 APRIL 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

W A

S H

IN

G

TO

N

J O

I N

T

B

A S

E

A

N D

R E

W S

V

L

I R

F

C

I L

I T

Y C

A M

P

S

P R

I N

G S

M

D

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

P -3

R E

LO

C

A

TE

H A

ZA

R

D O

U S

C A

R G

O P

A D

A N

D E

O D

P R

O

FI

C

IE

N C

Y R

A N

G E

W A

S H

I N

G T

O

V

Y

Y

A R

D W

A S

H I N

G T

O N

D

C

N40080-22-R-8580

1396650

PROFESS IONAL ENG

I N

EE

R

ST

AT

E OF MARYLANDE

I

L IP

C

H

CR

R K

U

No . 28557

M A

AT

M

ON

M D

E

N

O

S

F

S

TO

R M

S E

W E

R P

R O

FI

LE

S

CU-202

AutoCAD SHX Text

FINISHED GRADE

AutoCAD SHX Text

EXISTING GROUND

AutoCAD SHX Text

STORMWATER DETENTION

AutoCAD SHX Text

10-YEAR HGL

AutoCAD SHX Text

10-YEAR HGL

AutoCAD SHX Text

10-YEAR HGL

AutoCAD SHX Text

10-YEAR HGL

AutoCAD SHX Text

10-YEAR HGL

AutoCAD SHX Text NOTES: 1. MINIMUM COVER FOR STORM SEWER = 2.0 FT MINIMUM COVER FOR STORM SEWER = 2.0 FT 2. MINIMUM CLEARANCE FOR CROSSING UTILITIES = 18 IN. MINIMUM CLEARANCE FOR CROSSING UTILITIES = 18 IN.

AutoCAD SHX Text

EXISTING GROUND

AutoCAD SHX Text

FINISHED GRADE

AutoCAD SHX Text

CONNECT TO EXISTING 24-INCH RCP STORM SEWER

AutoCAD SHX Text 09/26/2022

AutoCAD SHX Text

AutoCAD SHX Text 0 ISSUE FOR CONSTRUCTION 09/26/2022ISSUE FOR CONSTRUCTION 09/26/2022 09/26/202209/26/2022

AutoCAD SHX Text

1 AMENDMENT 0005 04/15/2023AMENDMENT 0005 04/15/2023 04/15/202304/15/2023

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text 13140407

AutoCAD SHX Text

AutoCAD SHX Text 100'

AutoCAD SHX Text 0'

AutoCAD SHX Text 1"=50'

AutoCAD SHX Text 50'

AutoCAD SHX Text 200'

AutoCAD SHX Text 150'

AutoCAD SHX Text 250'

AutoCAD SHX Text 10'

AutoCAD SHX Text 0'

AutoCAD SHX Text 1"=5'

AutoCAD SHX Text 5'

AutoCAD SHX Text 20'

AutoCAD SHX Text 15'

AutoCAD SHX Text 25'

AutoCAD SHX Text

HORIZONTAL SCALE:

AutoCAD SHX Text

VERTICAL SCALE:

AutoCAD SHX Text

File details come from the government source that posted it. Updated .