CU-204_Amend 6 (2).pdf
PDF 982 KB Posted
- Attached to
- N4008023R0020 LARGE PROJECTS MULTIPLE AWARD CONSTRUCTION CONTRACT (MACC) Federal contract opportunity
- Solicitation number
- N4008023R0020
About this file
This document contains construction drawings and profiles for a storm sewer project. Key details include storm sewer structure profiles from SD1 to SD2, from P-EX2 to SD66, and from SD68 to SD67, with notes specifying minimum cover and clearance for storm sewers and crossing utilities. Additional information includes a box culvert wing wall and table, with a note requiring box culverts to be constructed with gasketed watertight joints. Horizontal and vertical scales, issue dates, drawing numbers, and the professional engineer's certification information are also included.
View the file
Other files for this federal contract opportunity
Show all 50
N4008023R0020 LARGE PROJECTS MULTIPLE AWARD CONSTRUCTION CONTRACT (MACC) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STORM SEWER STRUCTURES SD1 TO SD2 PROFILE
9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+0019+50
STORM SEWER STRUCTURES P-EX2 TO SD66 PROFILE
0+00 1+00 2+00 3+00 4+004+40
STORM SEWER STRUCTURE SD68 TO SD67 PROFILE
-0+400+00 1+00 2+00 3+00 4+00 4+75
BOX CULVERT WING-WALL TABLE
BOX CULVERT TABLE
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O
F
T
H E
A V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
DRAWFORM REVISION: 06 APRIL 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
W A
S H
IN
G
TO
N
J O
I N
T
B
A S
E
A
N D
R E
W S
V
L
I R
F
C
I L
I T
Y C
A M
P
S
P R
I N
G S
M
D
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
P -3
R E
LO
C
A
TE
H A
ZA
R
D O
U S
C A
R G
O P
A D
A N
D E
O D
P R
O
FI
C
IE
N C
Y R
A N
G E
W A
S H
I N
G T
O
V
Y
Y
A R
D W
A S
H I N
G T
O N
D
C
N40080-22-R-8580
1396650
PROFESS IONAL ENG
I N
EE
R
ST
AT
E OF MARYLANDE
I
L IP
C
H
CR
R K
U
No . 28557
M A
AT
M
ON
M D
E
N
O
S
F
S
TO
R M
S E
W E
R P
R O
FI
LE
S
CU-204
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
EXISTING GROUND
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
EXISTING GROUND
AutoCAD SHX Text
EXISTING GROUND
AutoCAD SHX Text
BOX CULVERT MUST BE CONSTRUCTED WITH GASKETED WATERTIGHT JOINTS (ASTM C 1677)
AutoCAD SHX Text
10-YEAR HGL
AutoCAD SHX Text
10-YEAR HGL
AutoCAD SHX Text
10-YEAR HGL
AutoCAD SHX Text
BIO-SWALE FILTER MATERIAL
AutoCAD SHX Text
BIO-SWALE FILTER MATERIAL
AutoCAD SHX Text NOTES: 1. MINIMUM COVER FOR STORM SEWER = 2.0 FT MINIMUM COVER FOR STORM SEWER = 2.0 FT 2. MINIMUM CLEARANCE FOR CROSSING UTILITIES = 18 IN. MINIMUM CLEARANCE FOR CROSSING UTILITIES = 18 IN.
AutoCAD SHX Text 09/26/2022
AutoCAD SHX Text
AutoCAD SHX Text 0 ISSUE FOR CONSTRUCTION 09/26/2022ISSUE FOR CONSTRUCTION 09/26/2022 09/26/202209/26/2022
AutoCAD SHX Text
1 AMENDMENT 0005 04/15/2023AMENDMENT 0005 04/15/2023 04/15/202304/15/2023
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text 13140409
AutoCAD SHX Text
AutoCAD SHX Text 100'
AutoCAD SHX Text 0'
AutoCAD SHX Text 1"=50'
AutoCAD SHX Text 50'
AutoCAD SHX Text 200'
AutoCAD SHX Text 150'
AutoCAD SHX Text 250'
AutoCAD SHX Text 10'
AutoCAD SHX Text 0'
AutoCAD SHX Text 1"=5'
AutoCAD SHX Text 5'
AutoCAD SHX Text 20'
AutoCAD SHX Text 15'
AutoCAD SHX Text 25'
AutoCAD SHX Text
HORIZONTAL SCALE:
AutoCAD SHX Text
VERTICAL SCALE:
AutoCAD SHX Text
File details come from the government source that posted it. Updated .