SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION A - SOLICITATION / CONTRACT FORM
The required response date/time has changed from 27-Nov-2018 02:00 PM to 13-Dec-2018 02:00 PM.
SECTION B - SUPPLIES OR SERVICES AND PRICES
The following have been added by full text:
REQUEST FOR CLARIFICATIONS #3
REQUEST FOR SPECIFICATION CLARIFICATION
SPECIFICATION ITEM NO.: 0602
PARAGRAPH / SECTION NO 2.2
TITLE: ACCOMMODATION LADDER INSPECTION AND LOAD TESTING (5-YR) REV –
QUESTION:
Paragraph 7.3 directs contractor to perform reference 2.2 maintenance and testing, utilizing material provided in para 3.2.2 as required.
Please provide reference 2.2
ANSWER:
Please see attached Reference: Reference was mis-titled. (611_MSC Circ 1331 Guidelines for Embarkation.pdf)
SPECIFICATION ITEM NO.: 0910
PARAGRAPH / SECTION NO 3.1.1, 4.0, 7.0
TITLE: OVERHAUL SEA VALVES REV-
3.1.1 a. for location, says “see sea valves table on sheet 5 of reference 2.1 (for guidance only)”. 7.0 Statement of work has specific lists of valves and operators to be addressed. Paragraph 7.5 requires testing of 24” and 30” valves removed. Contractor has not removed these valves or any other valves not listed in 4.2.1, 4.2.2 and 4.2.3 and is not working any actuators other than those listed in 7.1.1, 7.1.2 & 7.1.3.
Please confirm and or provide clear direction.
ANSWER:
Government requests all valves listed in Reference 2.1 be pulled for inspection cleaning and testing. 7.1.1, 7.1.2, 7.1.3 list interferences for valves (reach Rods and Attachments). GFM is pending, at a minimum, valves are to be pulled, cleaned and report status/possibility for repair/reuse.
SPECIFICATION ITEM NO.: 0602
PARAGRAPH / SECTION NO 3.1.2. 4.0 and J-4
TITLE: T-AKE CLASS HYDRA RADIO UPGRADE (T-ALT 472)
In paragraph 3.1.2 list equipment for the XG-75 Shipset HYDRA System.
Who is supplying the equipment, in paragraph 4.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICES: None, but the manufacturers’ representatives Harris Corporation indicated that MSC will be supplying the equipment and the J-4 BRASHEAR_GFP_Module_AttachmentTemplate has the XG-75 equipment listed.
ANSWER:
GFM will not be available in time for availability. Please omit pricing for this work item; cancel work item.
(End of Summary of Changes)
File details come from the government source that posted it.