J_-_2_Category_A_Items_27_May_2016.xlsm
XLSM spreadsheet 40 KB Posted
- Attached to
- USNS SACAGAWEA: Regular Scheduled Overhaul/Dry-Docking Federal contract opportunity
- Solicitation number
- N32205-16-R-4311
About this file
J-2 ATTACHMEN5T
View the file
Other files for this federal contract opportunity
Show all 27
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Cat A Items
| CATEGORY “A” ITEMS | |||||||||||
| GENERAL REQUIREMENT | PRIME Contractor | SUB Contractor | OTHER COSTS | TOTAL PRICE | |||||||
| ITEM NO. | TITLE CAT A ITEM | PRIME L/H | LABOR PRICE | MATERIAL PRICE | SUB L/H | LABOR PRICE | MATERIAL PRICE | TOTAL LABOR HOURS | TOTAL MATERIAL | ||
| CATEGORY "A" | |||||||||||
| 000 | GENERAL REQUIREMENTS | ||||||||||
| 001 | Intent, Scope, General Requirements and Definitions | NSP | NSP | NSP | $0 | ||||||
| 002 | Technical and Manufacturer’s Representatives | NSP | NSP | NSP | $0 | ||||||
| 003 | Approach, Berth, and Mooring Requirements | NSP | NSP | NSP | $0 | ||||||
| 004 | Testing and Quality Assurance | NSP | NSP | NSP | $0 | ||||||
| 005 | Electrical Safety Procedure Requirements | NSP | NSP | NSP | $0 | ||||||
| 006 | Heavy Weather Plan | NSP | NSP | NSP | $0 | ||||||
| 007 | Cold Weather Plan | NSP | NSP | NSP | |||||||
| 010 | Furnish Office for Overhaul Management Team (OMT) | - 0 | $ - 0 | $0 | |||||||
| 011 | Furnish General Services | - 0 | $ - 0 | $0 | |||||||
| 012 | Telephone Services | - 0 | $ - 0 | $0 | |||||||
| 013 | Project Planning and Production Status Monitoring Reports | - 0 | $ - 0 | $0 | |||||||
| 014 | Preparation of Weight and Moment Report | - 0 | $ - 0 | $0 | |||||||
| 015 | Integrated Logistics and GFM Support Requirements | - 0 | $ - 0 | $0 | |||||||
| 016 | Fire Protection and Ship’s Safety Program | - 0 | $ - 0 | $0 | |||||||
| 017 | Handling Ship’s Stores | - 0 | $ - 0 | $0 | |||||||
| 018 | Delivery and Redelivery of the Vessel | - 0 | $ - 0 | $0 | |||||||
| 019 | Shipboard Access and Security | - 0 | $ - 0 | $0 | |||||||
| 020 | Gas Free Certificates | - 0 | $ - 0 | $0 | |||||||
| 021 | Clean and Gas Free Tanks, Voids, Cofferdams and Spaces | - 0 | $ - 0 | $0 | |||||||
| 022 | Dock Trials and Sea Trial | - 0 | $ - 0 | $0 | |||||||
| 023 | Hazardous Waste Disposal | - 0 | $ - 0 | $0 | |||||||
| 024 | Physical Security at Private Contractor's Facility | NSP | NSP | NSP | $0 | ||||||
| 100 | HULL STRUCTURE | ||||||||||
| 101 | Ballast Tank Zink Inspection | - 0 | $ - 0 | $0 | |||||||
| 102 | Tank Vents Inspection and Renewal | - 0 | $ - 0 | $0 | |||||||
| 104 | Helo Deck and Helo Hangar Deck Non-Skid Renewal | - 0 | $ - 0 | $0 | |||||||
| 105 | Deck House Preservation - Full Blast | - 0 | $ - 0 | $0 | |||||||
| 106 | UNREP Stations Deck Non-Skid Renewal | ||||||||||
| 107 | RAS/FAS Station Kingposts and Ram Tensioners Preservation | - 0 | $ - 0 | $0 | |||||||
| 108 | Tank Boundary Testing and Structural Survey | - 0 | $ - 0 | $0 | |||||||
| 109 | Hull Gauging Suspect Areas | - 0 | $ - 0 | $0 | |||||||
| 111 | Bow Fairlead Roller Repair | - 0 | $ - 0 | $0 | |||||||
| 112 | Saltwater Ballast Tanks Preservation and Spot Repairs | - 0 | $ - 0 | $0 | |||||||
| 113 | Port Bulwark Closed Chock Replacement | - 0 | $ - 0 | $0 | |||||||
| 114 | Bollards, Bitts, Fairleads, Stand Rollers and Chocks SWL Marking | - 0 | $ - 0 | $0 | |||||||
| 117 | Starboard Side Plennum Louver and Screens Repairs | - 0 | $ - 0 | $0 | |||||||
| 118 | 01, 02 Deck Houses and Breakwater Preservation and Painting | - 0 | $ - 0 | $0 | |||||||
| 131 | MV-22 Capablity 1 Enhancement (T-A-LT 453) | - 0 | $ - 0 | $0 | |||||||
| 132 | Convert Ballast Tank to Greywater Holding Tank (T-ALT 429) | - 0 | $ - 0 | $0 | |||||||
| 133 | Oily Water Tank Conversion (T-ALT 430) | - 0 | $ - 0 | $0 | |||||||
| 135 | Roller Chocks Replacement (T-ALT 136) | - 0 | $ - 0 | $0 | |||||||
| 200 | MACHINERY, PROPULSION | ||||||||||
| 201 | Propulsion Motor and Coolers Cleaning, Inspection and Maintenance | - 0 | $ - 0 | $0 | |||||||
| 203B | MDGs Fluid Flexible Connectors Replacement | - 0 | $ - 0 | $0 | |||||||
| 204 | MDEs Automation Annual Testing | - 0 | $ - 0 | $0 | |||||||
| 205 | MDG Annual Automation and Propulsion Control Inspection and Testing | - 0 | $ - 0 | $0 | |||||||
| 206 | MDGs and EDG Flexible Coupling (Vulkan) Inspection and EDG Coupling Replacement | - 0 | $ - 0 | $0 | |||||||
| 207 | Propulsion Motor Pedestal Bearing Inspections | - 0 | $ - 0 | $0 | |||||||
| 208 | MDG No. 4 and Turbocharger 6000 Hr. Overhaul | - 0 | $ - 0 | $0 | |||||||
| 216 | MDGs Inspection, Maintenance and Cleaning | - 0 | $ - 0 | $0 | |||||||
| 219 | MDGs Pedestal Bearing Inspections (RENK) | - 0 | $ - 0 | $0 | |||||||
| 231 | MDGs Splash Oil and Test Circuit Modification (T-ALT 381) | - 0 | $ - 0 | $0 | |||||||
| 232 | MDG SACOS UPS Upgrade (T-ALT 352) | - 0 | $ - 0 | $0 | |||||||
| 300 | ELECTRICAL | ||||||||||
| 302 | HV, SS, Emergency and Bow Thruster Switchboards, Load Centers, Control Centers and Transformers Cleaning and Maintenance | - 0 | $ - 0 | $0 | |||||||
| 304 | UPS, PLC and Thermography Survey and Inspections | - 0 | $ - 0 | $0 | |||||||
| 309 | Viking Shore Power Cable Adapters Modifications | - 0 | $ - 0 | $0 | |||||||
| 331 | OP-4 Storerooms Lighting Upgrade | - 0 | $ - 0 | $0 | |||||||
| 332 | Cargo Holds 1-6 Lighting Switch Installation (T-ALT 246) | - 0 | $ - 0 | $0 | |||||||
| 335 | M-711 Light Fixture Conversion to LED (T-ALT 246) | - 0 | $ - 0 | $0 | |||||||
| 400 | COMMUNICATION AND NAVIGATIONAL AIDS | ||||||||||
| 401 | ADNS-SFF System Support | - 0 | $ - 0 | $0 | |||||||
| 402 | Comms System Maintenance and Antennas System Preventive Maintenance | - 0 | $ - 0 | $0 | |||||||
| 404 | Bridge Equipment Survey and ECHO Depth Sounder Preventive Maintenance | - 0 | $ - 0 | $0 | |||||||
| 405 | OE-570/WSC Antenna System Maintenance | - 0 | $ - 0 | $0 | |||||||
| 406 | Doppler Speed Log Replacement (T-ALT 431) | - 0 | $ - 0 | $0 | |||||||
| 431 | Gyrocompass MK27F Upgrade (T-ALT 348) | - 0 | $ - 0 | $0 | |||||||
| 433 | ECDIS VisionMaster VMFT Installation and VDR Upgrade (T-ALT 224, 347, 413) | - 0 | $ - 0 | $0 | |||||||
| 434 | Satamatics 101 D+ Ship's Security Alert System (SASS) Replacement (T-ALT 438) | - 0 | $ - 0 | $0 | |||||||
| 500 | MACHINERY, AUXILIARY SYSTEMS | ||||||||||
| 501B | Firefighting 5-Year Testing and Inspection | - 0 | $ - 0 | $0 | |||||||
| 502 | Distiller Flow Meter Replacement (T-ALT 340) | ||||||||||
| 503 | Self Contained Breathing Apparatus (SCBA) Annual Inspection, Testing and Recertification | - 0 | $ - 0 | $0 | |||||||
| 504B | Cargo Cranes 5-Year Retesting Surveys, Hydraulic Hoses and Wire Rope Replacement | - 0 | $ - 0 | $0 | |||||||
| 507 | EDG Flexible Hoses 5-Year Replacement | - 0 | $ - 0 | $0 | |||||||
| 509B | Distilling Plants No. 1 & 2 Cleaning, Inspection and Maintenance | - 0 | $ - 0 | $0 | |||||||
| 511 | Anchor and Mooring Winches Testing and Inspection | - 0 | $ - 0 | $0 | |||||||
| 514 | Relief Valves Testing | - 0 | $ - 0 | $0 | |||||||
| 515 | Air Receivers and HP Air Flasks Open and Inspection and HP Air Flasks NDT | - 0 | $ - 0 | $0 | |||||||
| 519 | LTFW Coolers Cleaning and Gasket Material Changeout (T-ALT 426) | - 0 | $ - 0 | $0 | |||||||
| 520 | HTFW Coolers Cleaning and Gasket Material Changeout (T-ALT 426) | - 0 | $ - 0 | $0 | |||||||
| 528 | Cargo Hold Magazine Sprinkler CLA Valves Overhaul | - 0 | $ - 0 | $0 | |||||||
| 532 | Firemain Casacade Orificial Restrictive Device (CORD) Repairs | - 0 | $ - 0 | $0 | |||||||
| 533 | MDG and EDG Start Air Compressors Overhaul | - 0 | $ - 0 | $0 | |||||||
| 544 | EDG Alignment, Inspection,Testing and Recertification | - 0 | $ - 0 | $0 | |||||||
| 545 | VAF Oilcon MK-6 Oil Discharge Monitoring Equipment (ODME) Calibration | - 0 | $ - 0 | $0 | |||||||
| 546 | Personnel Elevator 10-Year Maintenance and Overhaul | - 0 | $ - 0 | $0 | |||||||
| 547 | Miscellaneous Piping Repairs | - 0 | $ - 0 | $0 | |||||||
| 549 | MMR AFFF Piping Replacement (T-ALT 394) | - 0 | $ - 0 | $0 | |||||||
| 550 | Cargo Pump Room AFFF Piping Replacement (T-ALT 394) | - 0 | $ - 0 | $0 | |||||||
| 551 | Potable Water Heaters Open and Inspection | - 0 | $ - 0 | $0 | |||||||
| 552 | Genie Manlift 5-Year Maintenance and Recertification | - 0 | $ - 0 | $0 | |||||||
| 553 | Cargo Brine System Isolation Valves Replacement, Pump Replacement and Piping Modifications (T-ALT 349) | - 0 | $ - 0 | $0 | |||||||
| 554 | Shipboard Gage and Meter Calibrations | - 0 | $ - 0 | $0 | |||||||
| 555 | Cargo Crane Boom Rest Foundation Reinforcement (T-ALT 402) | - 0 | $ - 0 | $0 | |||||||
| 567 | Cargo Weapons Elevator Gratings Repairs | - 0 | $ - 0 | $0 | |||||||
| 558 | Cargo Weapons Elevators Recertification Support Item | - 0 | $ - 0 | $0 | |||||||
| 559 | Reverse Osmosis Sea Suction Relocation (T-ALT 351) | - 0 | $ - 0 | $0 | |||||||
| 560 | Marpol Annex VI Fuel Sampling Requirements-Flange Installations (T-ALT 377) | - 0 | $ - 0 | $0 | |||||||
| 561 | Lagging Insulation Preservation and Repairs | - 0 | $ - 0 | $0 | |||||||
| 562 | Deck House Firemain Isolation Valves Installation (T-ALT 367) | - 0 | $ - 0 | $0 | |||||||
| 563 | High Pressure Air Unions Replacement | - 0 | $ - 0 | $0 | |||||||
| 565 | 04, 05 and 06 Level Stateroom Shower/Head Decks Renewal | - 0 | $ - 0 | $0 | |||||||
| 567 | Air Conditioning and Cargo Refrigeration Plant Expansion Joints Replacement | - 0 | $ - 0 | $0 | |||||||
| 568 | Sludge Incinerator Inspection, Maintenance and Sludge Tank Heater Installation (T-ALT 218) | - 0 | $ - 0 | $0 | |||||||
| 569 | Machinery and Cargo OWS Inspection, Cleaning and Recertification | - 0 | $ - 0 | $0 | |||||||
| 570 | JP-5 Fuel Flowmeter Installation (T-ALT 322) | - 0 | $ - 0 | $0 | |||||||
| 571 | Central Seawater Spool Piece Repairs, Modifications (T-ALT 238) | - 0 | $ - 0 | $0 | |||||||
| 572 | CMWD Carbon Steel Piping and Check Valve Assy Replacement | - 0 | $ - 0 | $0 | |||||||
| 573 | Rudder Stock Gland Seal Inspection | - 0 | $ - 0 | $0 | |||||||
| 574 | Machinery Oily Water Separator Upgrade (T-ALT 430) | - 0 | $ - 0 | $0 | |||||||
| 575 | Miscellaneous Valves Repairs | - 0 | $ - 0 | $0 | |||||||
| 600 | OUTFIT, FURNISHINGS AND HABITABILITY | ||||||||||
| 602 | Accommodation Ladders 5-Year Inspection and Load Testing | - 0 | $ - 0 | $0 | |||||||
| 603 | Lifeboats Certification 5-Year Maintenance and Falls Renewal | - 0 | $ - 0 | $0 | |||||||
| 604 | Rescue Boats 5-Year Recertification, Maintenance and Falls Renewal | - 0 | $ - 0 | $0 | |||||||
| 605 | Liferafts Testing and Recertification | - 0 | $ - 0 | $0 | |||||||
| 609 | Immersion Suit Testing and Inspection | - 0 | $ - 0 | $0 | |||||||
| 613 | VCHT Sewage System Piping Cleaning/Flush | - 0 | $ - 0 | $0 | |||||||
| 631 | Lifeboats & Rescue Boats Release Hooks Upgrade (T-ALT 376) | - 0 | $ - 0 | $0 | |||||||
| 632 | VCHT Check Valve Installation (T-ALT 362) | - 0 | $ - 0 | $0 | |||||||
| 800 | HEATING, VENTILATION, AND AIR CONDITIONING | ||||||||||
| 801 | Galley Exhaust Duct Cleaning | - 0 | $ - 0 | $0 | |||||||
| 802 | Laundry Exhaust Duct Cleaning | - 0 | $ - 0 | $0 | |||||||
| 803 | Air Conditioning Plants Servicing and Maintenance | - 0 | $ - 0 | $0 | |||||||
| 804 | Cargo Refrigeration Plant Compressors Overhaul | - 0 | $ - 0 | $0 | |||||||
| 805 | AHU Heaters Replacement and Berps Installation | - 0 | $ - 0 | $0 | |||||||
| 831 | Shipyard Support for HVAC Variable Speed Drive Installation (iHVAC) (T-ALT 319) | - 0 | $ - 0 | $0 | |||||||
| 832 | Shipyard Support for Chiller Variable Speed Drive Installation (iHVAC) (T-ALT 319) | - 0 | $ - 0 | $0 | |||||||
| 833 | Galley HVAC Modifications (T-ALT 330) | - 0 | $ - 0 | $0 | |||||||
| 900 | DRY-DOCKING | ||||||||||
| 901 | Dry-Docking and Undocking | - 0 | $ - 0 | $0 | |||||||
| 903 | Propeller Shaft and Stern Tube Inspection (Includes Reference Cells Removal and Tube Recoating) | - 0 | $ - 0 | $0 | |||||||
| 904 | Stern Tube Seal Inspection | - 0 | $ - 0 | $0 | |||||||
| 906 | Bow Thruster 5-Year Maintenance | - 0 | $ - 0 | $0 | |||||||
| 907 | Bow Thruster Propeller Polish | - 0 | $ - 0 | $0 | |||||||
| 908 | Zinc Anode Renewals in Seachests, Rope Guard and Bow Thruster | - 0 | $ - 0 | $0 | |||||||
| 909 | Range and Paint Ground Tackle | - 0 | $ - 0 | $0 | |||||||
| 910 | Sea Valves Overhaul and Testing | - 0 | $ - 0 | $0 | |||||||
| 911 | Inspect and Repair Cathodic Protection | - 0 | $ - 0 | $0 | |||||||
| 912 | Shaft Grounding Preventive Maintenance | ||||||||||
| 913 | Waster Sleeves Renewal | - 0 | $ - 0 | $0 | |||||||
| 914 | Bilge Keel Stabilizers Inspection and Float Coat | - 0 | $ - 0 | $0 | |||||||
| 915 | Underwater Hull Cleaning and Painting - Full blast | - 0 | $ - 0 | $0 | |||||||
| 917 | Freeboard Cleaning and Painting - Full Blast | - 0 | $ - 0 | $0 | |||||||
| 920 | Bow Thruster Cooling Regulator Installation (T-ALT 227) | - 0 | $ - 0 | $0 | |||||||
| 924 | Propeller Boss Cap Replacement (T-ALT 325) | - 0 | $ - 0 | $0 | |||||||
| 925 | Bow Thruster Tunnel Grating Repairs | - 0 | $ - 0 | $0 | |||||||
| 1000 | UNREP GEAR | ||||||||||
| 1001 | Helo Deck Safety Nets Refurbishment, Rewiring and Load Testing | $ - 0 | $0 | ||||||||
| 1002 | RAS Station Sliding Block Drive Chain Replacement and Guide Rail Refurbishment | - 0 | $ - 0 | $0 | |||||||
| TOTAL CAT "A" | $0.00 |
Attachment J-2
| USNS SACAGAWEA (T-AKE 2) | CONTRACTOR PRICE BREAKDOWN |