Sheet1

Pre-Proposal Information (PPI)

4-Dec-17SOLICITATION NO: N00024-18-R-4439
TITLE: USS COWPENS (CG 63) & USS GETTYSBURG (CG 64)NAVSEA POC:

Billy Castleberry, billy.castleberry@navy.mil

POC PHONE: (202) 781-1248

ITEM NO: 314-11-001 CONTRACTOR QUESTION 10: Paragraph 3.1, states “Disconnect electrically and mechanically, remove existing and install new electrical power supply cables identified in 1.3 and located in 1.2, in accordance with 2.2, using 2.3 through 2.7 for guidance”.

• Contractor notes the paragraph as written does not state to accomplish reference 2.2, drawing 320-8646188, ShipAlt CG47-83505.02K Superstructure Fatigue & Sensitization 60HZ PWR SYS MOD.

Paragraph 3.1.3, states “Accomplish the requirements of 009-12 of 2.1, including Table 2, Column C, lines one through 7 and Nondestructive testing in accordance with line 10. Accomplish aluminum welding in accordance with 2.8”.

• Contractor notes that paragraph 3.1 does not state to accomplish reference 2.2 thus this paragraph is not required.

Paragraph 3.1.3.1, states “Accomplish the Process Control Procedure (PCP) requirements 009 09 of 2.1 for aluminum welding in accordance with 2.8”.

• Contractor notes that paragraph 3.1 does not state to accomplish reference 2.2 thus this paragraph is not required.

QUESTION: Can the Customer provide clarification as the disparities identified above regarding the requirements of paragraphs 3.1.1 and 3.1.3.1, and will an Amendment be issued providing a revised specification be issued?

GOVERNMENT RESPONSE:

No Welding required. LAR 83505.02/CG63/0108 envoked in ERRATA 3. Correction provided in CG63 Errata 3.

TITLE: Electrical Power Supply Cables; replace
PARA. NO:
PAGE NO:

ITEM NO: 588-21-002 Gettysburg CONTRACTOR QUESTION 29: Para 3.2 states to install and align the hoist assembly, and 3.2.2 involves welding. Does this hoist require assembly? If so, please provide what needs to be assembled. Further, all the references 2.2 - 2.6 were not provided . Please provide these drawings. GOVERNMENT RESPONSE:

Addressed in Reference Disk dated 11/21/17. Hoist is fully assembled, does not required assembly.

TITLE: Bridge Crane Hoist
PARA. NO: 2.2 - 2.6
PAGE NO: 1

ITEM NO: 495-90-002 CONTRACTOR QUESTION 41:

Para 3.2 states "Accomplish the requirements of 2.2 through 2.16 and applicable portions of SA 88467.03K in 2.17 through 2.19 including all general, local, special, test and rip-out notes, using 2.23 and 2.24 for guidance. Work is to be completed in accordance with the schedule provided in 2.27."

Para 3.2.1 states "Fabricate, fit and install from raw material provided by 2.25, 2.26 and 2.17 through 2.19 and 5.3, for accomplishing the requirements of 2.2 through 2.16 and 2.20 through 2.22."

For estimating purposes please clarify the intent of para 3.2.1. Who is accomplishing ref 2.20 through 2.22 since there is no requirement to accomplish these paragraphs in 3.2?

please advise

GOVERNMENT RESPONSE:

Requirements of references are divided between MSR and AIT as stated in work item.

ShipAlt CG47-88467.03K Canes MOD 01 Classified LAN Install; accomplish
para 3.2.1
PAGE NO: 3

ITEM NO: 593-21-001 CONTRACTOR QUESTION 45:

Para 3.5 states "Accomplish 009-22 of 2.1. for the cable(s) terminating in the equipment listed in 1.3."

FY-18 (CH-1) STD Items 009-22 shows CANCELLED as of 11/18/16.

Please advise and or issue Errata.

GOVERNMENT RESPONSE:

Correction provided in CG63 Errata 2. Agree with contractor 009-22 is cancelled. Delete Para 3.5 from work specification 593-21-001.

OILY WASTE WTR TRANSFER PUMP ASSEMBLIES; INSTALL
PARA. NO: 3.5
PAGE NO: 2 of 3

ITEM NO: 593-21-002 CONTRACTOR QUESTION 46:

Para 3.3 states "Accomplish 009-22 of 2.1. for the cable(s) terminating in the equipment listed in 1.3. USING 2.7. and 2.8. for guidance."

FY-18 (CH-1) STD Items 009-22 shows CANCELLED as of 11/18/16.

Please advise and or issue Errata.

GOVERNMENT RESPONSE:

Correction provided in CG63 Errata 2. Agree with contractor 009-22 is cancelled. Delete Para 3.3 from work specification 593-21-002.

TITLE: OILY WASTE WTR DRAIN PUMPS; INSTALL
PARA. NO: 3.3
PAGE NO: 3 of 5

ITEM NO: 593-11-010 CONTRACTOR QUESTION 47:

Para 3.3 states "Accomplish 009-22 of 2.1. for the Pulper controller electrical cables I.A.W. 2.2. and 2.3."

Please advise and or issue Errata.

GOVERNMENT RESPONSE:

Correction provided in CG63 Errata 2. Agree with contractor 009-22 is cancelled. Delete Para 3.3 from work specification 593-11-010.

TITLE: PULPER CONTROL PANEL; REPLACE
PARA. NO: 3.3.
PAGE NO: 1 OF 2

ITEM NO: 593-11-011 CONTRACTOR QUESTION 48:

Para 3.4 states "Accomplish 009-22 of 2.1. for the cable(s) terminating in the equipment listed in 1.3.1. and 1.3.2."

Please advise and or issue Errata. GOVERNMENT RESPONSE:

Correction provided in CG63 Errata 2. Agree with contractor 009-22 is cancelled. Delete Para 3.4 from work specification 593-11-011.

TITLE: CHT TNKS, HIGH LIQUID LEVEL ALARM SWITCHES; REPAIR
PARA. NO: 3.4.
PAGE NO: 2 OF 3

ITEM NO: 243-11-007, 243-11-008 CONTRACTOR QUESTION 59:

Paragraph 3.1 please provide contact information for the field service technical representative.

GOVERNMENT RESPONSE:

009-90 does not require the government to establish the OEM for the Bidder. It is the Bidders responsibility to submit the OEM in report specified in 009-90 PARA 3.1.5 and request approval to use OEM Rep.

TITLE: Bulkhead Seal Replacement
PARA. NO: 3.1
PAGE NO: 1
\
ITEM NO: 514-11-004CONTRACTOR QUESTION 60:

Equipments ID on 1.3.2, 1.3.10 , 1.3.11 , 1.3.13 , 1.3.14 and 1.3.15 were not found on the drawings listed on the spec as per these equipments.

Please provide the correct drawings or advise. GOVERNMENT RESPONSE:

Correction provided in CG63 Errata 3. Agree with contractor equipment ID will be address on corrected references.

TITLE: FCU AND FCA OVERHAUL
PARA. NO: 1
PAGE NO: 1

ITEM NO: 514-11-005 CONTRACTOR QUESTION 61:

ID no.1.3.2 and 1.3.5 has the same equipment description.

Please verify and advise.

GOVERNMENT RESPONSE:

Correction provided in CG63 Errata 2. 1.3.2 and 1.3.5 are duplicates. There should one FCA for each of the spaces identified in 1.2. Delete Para 1.3.5 because this is a duplicate of 1.3.2.

TITLE: FCU AND FCA OVERHAUL
PARA. NO: 1
PAGE NO: 1

ITEM NO: 980-11-004 CONTRACTOR QUESTION 63:

1. What is the intent of this item?

2. Please provide specific work scope for this individual.

3. Is it the Government’s intent to have a full time hygienist assigned to this work item? If so please modify specification to reflect this.

Please clarify. GOVERNMENT RESPONSE:

INDUSTRIAL HYGENIST SERVICES REQUIRED FOR THE DURATION OF THE EDSRA 18 AVAILABILITY REQUIRED BY STANDARD ITEMS. THIS WORK WILL BE DIRECTED BY SEA 21 FOR EXECUTION.

TITLE: Industrial Hygienist Provide
PARA. NO: 3.1-3.1.2
PAGE NO: 1

ITEM NO: 992-11-001 CONTRACTOR QUESTION 64:

Please identify the space locations of the five spaces that need temporay AC for bidding purposes.

GOVERNMENT RESPONSE:

Additional 5 spaces are not identified at this time. Will be known once ship is close to testing of Aegis and Combat systems.

TITLE: Temporary Service Provide
PARA. NO: 3.3.17.2-3.17.5
PAGE NO: 7

ITEM NO: 992-11-004 CONTRACTOR QUESTION 65:

The fuel depot in San Diego does not allow contractor supplied barges to enter or tow their barges.

Please advise.

GOVERNMENT RESPONSE:

Additional 5 spaces are not identified at this time. Will be known once ship is close to testing of Aegis and Combat systems.

TITLE: Fuel Assistance and TowBoat Service
PARA. NO: 3..2-3.3
PAGE NO: 1

ITEM NO: 992-11-006 CONTRACTOR QUESTION 66:

1. The crew size requirement to be transported for this specification appear to be excessive compared to other recent crew transport specifications. Please review and advise.

2. Recommend transporting the crew between 0500 to 0700 and 1500 to 1700 hours to optimize number of trips.

Please review and advise.

GOVERNMENT RESPONSE:

360 is a valid crew size.

TITLE: Crew Transportation Service
PARA. NO: 3.1-3.1.3
PAGE NO: 1

ITEM NO: 234-11-004 and 234-11-005 CONTRACTOR QUESTION 67:

Paragraph 3.2-3.2.1 please provide contact information for the field service technical representative.

Paragraph 3.3 please confirm that the technicians in this paragraph will be government provided, if not please supply contact information for these technicians.

GOVERNMENT RESPONSE:

NAVSEA Technical Representative shall be provided by the Regional Maintenance Center. Port Engineer/ Project Manager to provide more information once known where ships availability will be completed.

TITLE: MPGT Engine Install
PARA. NO: 3.2-3.3
PAGE NO: 1

ITEM NO: 992-31-001 CONTRACTOR QUESTION 75: 116 tanks, spaces and bilges are to be dealt with. Paragraph 3.1.7 says to remove up to 38,500 gallons of additional fluid from compensating and adjacent tanks listed in 1.2. Paragraph 3.3 specifies to pump tanks containing petroleum products to the low suction level of the tank and paragraph 3.4.2 specifies to remove an additional 5,000 gallons of petroleum fluids generated by the Navy after the initial certifications are complete. There is no initial amount of gallons ID to remove. For estimating proposes, please provide number of gallons of Compensating Water and number of gallons of Fuel/Oil products to be removed. GOVERNMENT RESPONSE:

Tank capacity references are to be used in estimating amounts to be removed.

TITLE: Pumping and Gas Free
PARA. NO:
PAGE NO:

ITEM NO: Missing 4720's CONTRACTOR QUESTION 81: 4720's are missing for the following items: 631-80-001, 150-90-004, 150-90-003 & 150-90-005. Please provide. GOVERNMENT RESPONSE:

Addressed in Reference Disk dated 11/21/17

TITLE:
PARA. NO:
PAGE NO:

ITEM NO: 555-11-004 CONTRACTOR QUESTION 84: Paragraph 3.4, states “Accomplish repairs of SOPV the material in 3.3.1 and using 2.2 and Chapter 6 of 2.5 for guidance.

• Contractor notes that there is no paragraph 3.3.1 included in this specification as written.

• Contractor notes that paragraph 3.4 appears not to provide accurate requirement to estimate and or execute.

QUESTION: Can the Customer provide clarification as the disparities identified above regarding the requirements of paragraph 3.4 and missing paragraph 3.3.1, and will an Amendment be issued providing a revised specification be issued?

GOVERNMENT RESPONSE:

Correction provided in CG63 Errata 3. Revised paragraph 3.4 via Errata 3 work spec.

TITLE: SOPV AFFF Modifications; accomplish
PARA. NO:
PAGE NO:

ITEM NO: 110-11-006 CONTRACTOR QUESTION 85: Paragraph 3.8, states “Accomplish the Requirements of 009-32 of 2.1 to include Table 4, Line 8A, Columns A & B for area located in 1.2.3”.

• Contractor notes there is no Table 4, Line 8A in 009-32 STD ITEMS FY-18 Ch.1 But there is in 009-32 STD ITEMS FY-18.

QUESTION: Can the Customer please advise as to the correct FY STD ITEMS are to be used and or if a correct Table and Line will be issued?

GOVERNMENT RESPONSE:

Correction provided in CG63 Errata 2. Para 3.8 should state "Accomplish the Requirements of 009-32 of 2.1 to include Table 3, Line 7, Columns A, B, and D for area located in 1.2.3". STD ITEMS FY-18 Ch-1

TITLE: Shell Plating, Crew Berthing; replace
PARA. NO:
PAGE NO:

ITEM NO: 150-11-001 CONTRACTOR QUESTION 99:

Paragraph 3.3.7 provides direction to "remove existing and install new material listed in 1.3.4 through 1.3.6 at 1.2.8 using 2.9 for guidance." There are no paragraphs 1.3.4 through 1.3.6 in the work item. The only paragraph is 1.3 and is noted as Not Applicable on the work item. Please advise.

GOVERNMENT RESPONSE:

Addressed ERRATA 2 CG 64

TITLE: Superstructure Repair; accomplish
PARA. NO: 3.7
PAGE NO: 1 of 5

ITEM NO: 123-11-004 CONTRACTOR QUESTION 100:

Please provide a copy of reference 2.2, 83059/CG64/001.

GOVERNMENT RESPONSE:

Addressed in Reference Disk dated 12/01/17

TITLE: Fuel Oil Tank Top Modification; accomplished
PARA. NO: 2.2
PAGE NO: 1 of 2

ITEM NO: 130-11-003 CONTRACTOR QUESTION 101:

Paragraph 3.5 calls out Table 2, Line 47 which is type G liquid non-skid. Paragraph 3.5.1 calls out 009-26 Attachment G which is slip resistant (peel & Stick) Type XI PS. Please clarify type of non-skid to be used.

GOVERNMENT RESPONSE:

Addressed ERRATA 2 CG 64

TITLE: Trimettallic Aircraft Securing Fitting; replace
PARA. NO: 3.5, 3.5.1
PAGE NO: 1 of 3

ITEM NO: 150-90-003 CONTRACTOR QUESTION 102:

Paragraph 3.17.1 provides direction to accomplish 009-26 Attachment G (peel and stick) for the accomplishment of 2.13 and 2.14. Should 2.14 (insulation) be 2.27 the weather deck covering drawing?

Please provide a copy of reference 2.26, 83506.06CG64P179.

GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64: Reference correction (2.14 to 2.27)

TITLE: ShipAlt CG47-83506.06 Fatigue & Sensitization Mod AFT; accomplish
PARA. NO: 2.13, 2.26, 2.27, 3.17.1
PAGE NO: 1, 2 of 6

ITEM NO: 150-90-004 CONTRACTOR QUESTION 103:

Please review the references in the subject paragraphs.

Reference 2.25 should be changed to 2.18 and 2.37 be changed to 2.28.

GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64:

Reference correction (2.25 to 2.18, 2.37 to 2.28)

TITLE: ShipAlt CG47-83506.04K, Superstructure Fatigue and Sensitization Modifications (AFT); accomplish
PARA. NO: 3.14, 3.14.1, 3.15
PAGE NO: 5 of 7

ITEM NO: 411-90-001 CONTRACTOR QUESTION 104:

Please clarify if 009-78 for PCMS needs to be called out in work item 411-90-001. Paragraph 3.1 states to use material listed in 2.30, 2.31 and 5.3. Reference 2.31 is the PCMS summary which shows (29 ea) type 3R tiles being installed in a portion of 2.29. Please advise.

GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64: Added 009-78 and reference for pcms installation requriement.

TITLE: ShipAlt CG47-78510.03K AWS: ACB12/TI12 CIC Display Upgrades (SPLITALT); accomplish
PARA. NO: 2.29, 2.31, 3.1, 5.3.2
PAGE NO: 1 thru 8

ITEM NO: 452-90-002 CONTRACTOR QUESTION 105:

Reference 2.2 references PCMS being in place. Has the PCMS been removed from the mast? There is GFM tiles in the 4720 for this ShipAlt. Should 009-78 be called out for the removal and installation of PCMS tiles after 2.2 is completed?

GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64: Added 009-78 and reference for pcms installation requriement.

TITLE: ShipAlt CG47-87310.03K, Remove AN/SPS-49 Radar System; accomplish
PARA. NO: 2.2
PAGE NO: 1 of 3

ITEM NO: 456-90-003 CONTRACTOR QUESTION 106:

Paragraph 3.1 states to accomplish the applicable portion of 2.20. Reference 2.20 is the PCMS drawing. Without 009-78 called out in the work item, Sht 14 & 150 of Ref 2.20 cannot be accomplished. Recommend including 009-78 into the work item or delete the reference to 2.20.

GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64: Added 009-78 and reference for PCMS installation requriement.

TITLE: ShipAlt CG47-77614.03K ACB12/TI12 OA Computer Upgrade (SPLITALT); accomplish
PARA. NO: 3.1
PAGE NO: 4 of 8

ITEM NO: 165-11-002 CONTRACTOR QUESTION 107:

Please provide a copy of reference 2.2, S9165-AH-MMA-010.

GOVERNMENT RESPONSE:

Addressed in Reference Disk dated 12/01/17

TITLE: Sonar Dome Rubber Window (SDRW); inspect
PARA. NO: 2.2
PAGE NO: 1 of 3

ITEM NO: 980-11-002 CONTRACTOR QUESTION 108:

Please provide a copy of "Attachment A" refererred to in paragraph 3.4 and 3.6.

GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64: Corrected Attachment A.

TITLE: AN/SPY-1B Radar Array Resurface Support; provide
PARA. NO: 3.4, 3.6
PAGE NO: 2 of 2

ITEM NO: 631-21-001 CONTRACTOR QUESTION 109:

Paragraph 3.2.1 states, "Accomplish the requirements of 009-32 of 2.1, including Table 5, Line 31 (powder coat) for each ventilation screen removed in 3.3." Paragraph 3.3 is a paragraph to accomplish 009-78.

Question 1) 3.2.1- if the vent screens are wrapped and protected in 3.1.2, will the Government provide a list or direction to remove the vent screens?

Question 2) 3.3 - what direction does 009-78 cover? There is no GFM for replacement, 3.5 covers painting areas contained by PCMS. Please clarify if the PCMS tile gets over-coated or removed.

GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64: Changed table line to local powdercoating.

TITLE: Superstructure Preservation; accomplish(OPTION ITEM)
PARA. NO: 3.2.1, 3.3, 3.5
PAGE NO: 1 of 2

ITEM NO: 512-11-006 CONTRACTOR QUESTION 110:

The Fluidized Bed Method of powder coating called out in 3.3 Table 2, Line 35 for the (2 ea) vent screens is less than 2 SF. Contractor requests the process be changed to traditional powder coating Table 5, Line 31.

GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64: Changed table line to local powdercoating.

TITLE: Vent Screen; replace
PARA. NO: 3.3
PAGE NO: 1 of 2

ITEM NO: 583-11-002 CONTRACTOR QUESTION 111:

The requirements of this paragraph appear to be incomplete. Paragraph states, "Accomplish the requirements of test Note T-2 of 2.3 for testing of newly installed boat davit, in accordance with 2.15 and 2.15, using Table 583.-7 of 2.- for guidance."

Please note the underlined areas of the paragraph and advise.

GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64: Corrected reference.

TITLE: Boat Davit; Repair
PARA. NO: 3.5
PAGE NO: 2 of 3

ITEM NO: 641-11-001 CONTRACTOR QUESTION 112:

Paragraph 3.9 has confusing references. Can the Government provide clarification for this paragraph?

Example - "accomplish 2.10 through 2.13 using 2.26 as guidance." Reference 2.26 is the vent insulation installation detail drawing. Should the 2.24 reference be changed to 2.10?

GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64: Corrected reference.

TITLE: Officers Habitability and Berthing Enhancement Project (HOFF and BOFF); accomplish
PARA. NO: 3.9
PAGE NO: 4, 5 of 7

ITEM NO: 641-11-001 CONTRACTOR QUESTION 113:

Paragraph 3.10 is the 009-26 deck covering. The accomplishment of 2.24 is the vent standard drawing. Should the reference be 2.11 the mod to deck covering drawing?

GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64: Corrected reference.

TITLE: Officers Habitability and Berthing Enhancement Project (HOFF and BOFF); accomplish
PARA. NO: 3.10
PAGE NO: 5 of 7

ITEM NO: 593-31-001 CONTRACTOR QUESTION 114:

Please provide a copy of reference 2.2, S9593-DP-MMM-010.

Please provide a copy of reference 2.3, S9593-C8-MMM-010. GOVERNMENT RESPONSE:

Addressed in Reference Disk dated 12/01/17

TITLE: Solid Waste Shredders; test
PARA. NO: 2.2, 2.3
PAGE NO: 1 of 2

ITEM NO: 514-23-001 CONTRACTOR QUESTION 115:

Please provide a copy of reference 2.9, S6435-CZ-MMA-010.

GOVERNMENT RESPONSE:

Addressed in Reference Disk dated 12/01/17

TITLE: Air Conditioning Plant No. 3; repair
PARA. NO: 2.9
PAGE NO: 2 of 5
ITEM NO: 631-12-002CONTRACTOR QUESTION 116:
The reference 2.2 called out in 3.1 states to use sheet 174 as guidance. The drawing listed in 2.2 is titled Paint Schedule when in fact the drawing number 6013793 is a 32 page document titled CORROSION CONTROL PLAN. Can the correct Paint Schedule number be provided or the correct sheet number for the preservation of the dirty side of No.3 intake?GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64: Corrected reference.

TITLE: Gas Turbine Generator No. 3 Intake (Dirty Side); preserve
PARA. NO: 2.2, 3.1
PAGE NO: 1 of 1

ITEM NO: 631-12-003 CONTRACTOR QUESTION 117:

Contractor requests the Government provide arrangement drawings for locations 1.2.2 - 1.2.5.

GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64: Corrected reference.

TITLE: Magazine; inspect and preserve
PARA. NO: References
PAGE NO: 1 of 3
ITEM NO: 634-11-009CONTRACTOR QUESTION 118:
Please clarify the locations and the decking called out in paragraphs 3.1 and 3.2. Locations 1.2.4 and 1.2.5 are listed in both the resurfacing and replacement paragraphs. Paragraph 1.2.7 is not called out. Should 3.2 be locations changed to be 1.2.6 & 1.2.7?GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64: Corrected reference.

TITLE: Cosmetic Polymeric Deck Covering Replacement and Resurfacing; accomplish
PARA. NO: 3.1, 3.2
PAGE NO: 1 of 3

ITEM NO: 472-90-001 CONTRACTOR QUESTION 119:

Please provide the folllowing references:

2.23, 80156.03K/CG64/P233 LAR HARDWARE

2.25, 4720/3 MATERIAL SUMMARY REPORT 80156.03K

2.26, 4720/3 MATERIAL SUMMMARY REPORT 71180K GOVERNMENT RESPONSE:

Addressed in Reference Disk dated 12/01/17

TITLE: ShipAlt CG47-80156K, CG47-71180K, An/Slq-32(V) 6 Hardware, Surface EW Improvement Blk 1B; accomplish
PARA. NO: 2.23, 2.25, 2.26
PAGE NO: 2 of 5

ITEM NO: 583-11-002 CONTRACTOR QUESTION 122: Paragraph 3.3, states “Remove existing, procure and install new gear pump listed in 1.3.1.1, in accordance with Paragraph 6-44 of 2.2”.

• Contractor notes paragraphs 3.4 through 3.7.2 directs the contractor to overhaul the motor in paragraph 1.3.1.2.

Paragraph 3.8, states “Disassemble, clean, inspect and repair the equipment listed in 1.3.1.1, and 1.3.1.2 in accordance with Chapters 6 and 7 of 2.2”.

• Contractor notes the specification directs to disassemble the pump in paragraph 1.3.1.1 and motor in paragraph 1.3.1.2.

Paragraph 3.10, states “Reassemble the equipment listed in 1.3.1.3 through 1.3.1.5, in accordance with Chapters 6 and 7 of 2.2”.

• Contractor notes the specification directs the contractor to reassemble the equipment in paragraphs 1.3.1.3 through 1.3.1.5 however these 1.3.1.3 through 1.3.1.5 do not exist in this specification as written.

Paragraph 3.11, states “Remove existing, procure and install new flexible hose assemblies in accordance with Chapter 5 of 2.2.

• Contractor is unable to identify any the flexible hoses within Chapter 5 of 2.2 to be replaced on this davit.

QUESTION: (1) Is it the Customer's intention in accordance with paragraphs 3.3 & 3.8 of the specification as written to disassemble the new pump and overhauled motor and clean, inspect and report?

QUESTION: (2) Can the Customer provide clarity regarding the disparities regarding paragraphs 3.10 through 3.11 and will a revised work specification be issue on a future Amendment?

GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 63

TITLE: Starboard Boat Davit Assembly Class “B” Overhaul and Install; accomplish
PARA. NO:
PAGE NO:

ITEM NO: 512-11-030 CONTRACTOR QUESTION 123: Paragraph 3.2, states “Prepare the ventilation system ducting listed in 1.3 for an internal and external visual inspection by removing and retaining for reuse all bolted and quick release hand-hole and man-hole cover plates, break-down and remove ventilation duct flanged joints and retain all usable fasteners for reinstallation”.

• Contractor notes there are more than 200 ventilation systems onboard this ship and as it is currently listed.

Paragraph 3.2.1, states “Accomplish a visual inspection of all ventilation system ducting listed in 1.3 for structural integrity, deterioration, pitting, cracks, areas of damaged or distortion, missing ducting or ducting components and damaged or missing insulation. Visual inspection shall be used to document all findings that are within line of sight. Video recording shall be used to document all inspection findings that are not visible as a result of ventilation duct and system component removals.

• Contractor notes each system requires 3 (V) (G) callouts throughout this specification as written… One for visual inspection, one for cleanliness and one for an op-test that equates more than 600 (V) (G) Callouts for this work item.

• Contractor notes there will not be enough time during this Period of Performance to complete all of the requirements for Work Item 512-11-030 as it will take well over 4 months just to perform the pre-cleaning and visual inspections, with (V) (G) callouts and reports.

Paragraph 3.7, states “Accomplish an operational test of the ventilation system(s) listed in 1.3 and located in 1.2 at systems normal operating pressure to ensure ventilation joint tightness. Allowable external leakage at each new and disturbed joint: None.

• Contractor notes the op-test on a vent cleaning project of this magnitude will be nearly impossible to finish within the Period of Performance as well, especially since most of the systems will not be operational until the end of the availability.

Contractor request the requirements of 3.2 through 3.2.1.1, and 3.7 through 3.9 be removed from the scope of work for Work Item 512-11-030.

QUESTION: Will an Amendment and/or an Errata be issued to remove the requirements of 3.2 through 3.2.1.1, and 3.7 through 3.9? GOVERNMENT RESPONSE:

Addressed ERRATA 2 CG 63

TITLE: Ventilation Duct Cleaning; accomplish
PARA. NO:
PAGE NO:

ITEM NO: 313-11-001 CONTRACTOR QUESTION 124: Paragraph 3.1.4, states “Accomplish the requirements of 009-22 of 2.1 for the cables terminating in the equipment listed in 3.1.

• Contractor notes that that NAVSEA Standard Items FY18 Change 1, Item 009-22 was Canceled 18 November 2016.

QUESTION: Does the Customer intend to issue an Amendment or an errata deleting paragraph 3.1.4 from the work item?

Note the response to this question also affects the following listed specifications and paragraphs,

• WI 512-11-003, Fan Room 01-392-2-Q Restoration; accomplish *Paragraphs 3.7.1

• WI 512-11-007, Fan Room 1-382-3-Q; refurbish *Paragraph 3.9

• WI 561-11-002, Steering Gear Hydraulic Power Unit (HPU) Main Pumps; install *Paragraph 3.3.1

• WI 588-21-005, Recovery Assist, Securing and Traversing (RAST) WHPU Motor; repair *Paragraphs 3.4

• WI 593-11-010, Pulper Control Panel; replace *Paragraph 3.4

• WI 593-21-001, Oily Waste Water Transfer Pump Assemblies; install *Paragraph 3.5

• WI 593-21-002, Oily Waste Water Drain Pumps; install *Paragraph 3.3

GOVERNMENT RESPONSE:

Addressed ERRATA 2 CG 63 Agree with Contractor 009-22 has been cancelled, Work item 313-11-001 Delete para 3.1.4 Work item 512-11-003 Delete Para 3.7.1 Work item 512-11-007 Delete Para 3.9 Work item 561-11-002 Delete para 3.3.1 Work item 588-21-005 Delete Para 3.4 Work item 593-21-001 Delete para 3.4 Work item 593-21-002 Delete para 3.3

TITLE: Battery Charger for Rigid-Hull Inflatable Boat (RHIB) No. One; install
PARA. NO:
PAGE NO:

ITEM NO: 110-11-013 CONTRACTOR QUESTION 125: Paragraph 3.1 states “Accomplish weld repair at the thinning area identified in 1.3.1 to restore the notch to the correct thickness, at the location listed in 1.2.1”.

• Contractor notes that this paragraph does not provide information regarding the quantity (square inches or feet) of weld repairs to be accomplished.

Paragraph 3.2 states “Accomplish vee-out and re-weld the flange to repair the incomplete existing butt weld identified in 1.3.2, at the location listed in 1.2.2”.

• Contractor notes that this paragraph does not provide information regarding the linear inches or feet of existing butt weld that require repair.

QUESTION: Can the Customer provide clarification as the disparities identified above regarding the requirements of paragraphs 3.1 and 3.2 and will an Amendment be issued providing a revised specification?

GOVERNMENT RESPONSE:

Correction provided in CG63 Errata 2. Para 3.1 added 144 Square inches Clad Weld Repair. 3.2 added 20 linear inches of vee out and weld repair.

TITLE: Structural Repairs, 5/54 Magazine; accomplish
PARA. NO:
PAGE NO:

ITEM NO: 110-11-018 CONTRACTOR QUESTION 126: Paragraph 3.1 states “Open, empty, clean, certify as gas free "Safe for Personnel and Safe for Hot Work" to the extent necessary to accomplish the requirements of this Work Item. (See note 4.1)”

• Contractor notes that the specification as written contains no note 4.1.

Paragraph 3.3 states “Accomplish the welding of unwelded portion of vertical stiffener identified in 1.3.1”.

• Contractor notes that this paragraph does not provide information regarding the linear inches or feet of vertical stiffener that requiring welding.

Paragraph 3.6 states “Accomplish the requirements of 009-25 of 2.1 for the local air hose test of disturbed structural boundaries. Allowable leakage: None. (See Note 4.2)”

• Contractor notes that the specification as written contains no note 4.2.

QUESTION: Can the Customer provide clarification as the disparities identified above regarding the requirements of paragraphs 3.1, 3.2 and 3.6 and will an Amendment be issued providing a revised specification?

GOVERNMENT RESPONSE:

Addressed ERRATA 2 CG 63 Para 3.1 and 3.6 see notes 4.1 and 4.2 should not exist. Para 3.3 to state Accomplish 4 Linear feet of welding the unwelded portion of vertical stiffener identified in 1.3.1.

TITLE: Structural Repairs, TWS Equipment Room; accomplish
PARA. NO:
PAGE NO:

ITEM NO: 251-11-003 CONTRACTOR QUESTION 127: Paragraph 3.6 states “Accomplish the requirements of 009-78 of 2.1”.

• Contractor notes that there is no PCMS Tile identified in Paragraph 5 as GFM

• Contractor notes that all PCMS material must be supplied by the Customer.

QUESTION: Can the Customer provide clarification as the disparities identified above regarding the requirements of paragraph 3.6 and the missing PCMS material not listed in paragraph 5 and will an Amendment be issued providing a revised specification?

GOVERNMENT RESPONSE:

Addressed ERRATA 2 CG 63 PCMS material should be identified in para 5.1 or associated with work item 472-11-001 for the istallation of PCMS

TITLE: Gas Turbine Generator No. One, 2 & 3 Moisture Separator System Refurbishment; accomplish
PARA. NO:
PAGE NO:

ITEM NO: 251-31-001 CONTRACTOR QUESTION 128: Paragraph 3.13 states: Accomplish the requirements of 009-78 of 2.1.

• Contractor notes that there is no PCMS Tile identified in Paragraph 5 as GFM

• Contractor notes that all PCMS material must be supplied by the Customer.

QUESTION: Can the Customer provide clarification as the disparities identified above regarding the requirements of paragraph 3.13 and the missing PCMS material not listed in paragraph 5 and will an Amendment be issued providing a revised specification?

GOVERNMENT RESPONSE:

Addressed ERRATA 2 CG 63 PCMS material should be identified in para 5.1 or associated with work item 472-11-001 for the istallation of PCMS

TITLE: Gas Turbine Module (GTM) Air Intake Moisture Separator System Refurbishment; accomplish
PARA. NO:
PAGE NO:

ITEM NO: 612-11-001 CONTRACTOR QUESTION 129: Paragraph 3.2 states “Accomplish the requirements of 009-78 of 2.1 at location listed in 1.2 for installation of new PCMS, using 2.2 as guidance”.

• Contractor notes reference 2.2 is drawing 612-6013727 Rev U, Arr and Det Guardrails, Stormrails and Lifelines, MDL 4 and does not provide any details regarding the quantity or installation of PCMS materials.

• Contractor notes that there is no PCMS Tile identified in Paragraph 5 as GFM

• Contractor notes that all PCMS material must be supplied by the Customer.

QUESTION: Can the Customer provide clarification as the disparities identified above regarding the requirements of paragraph 3.2 and the missing PCMS material not listed in paragraph 5 and will an Amendment be issued providing a revised specification?

GOVERNMENT RESPONSE:

Addressed ERRATA 2 CG 63 PCMS material should be identified in para 5.1 or associated with work item 472-11-001 for the istallation of PCMS

TITLE: Main Mast Platform Lifeline Stanchion Repair; accomplish
PARA. NO:
PAGE NO:

ITEM NO: 529-11-002 CONTRACTOR QUESTION 130: Paragraph 3.1 states “Accomplish the requirements of 009-90 of 2.1” and paragraph 3.1.1 states “Obtain the services of a qualified technical representative to provide on-site assistance and guidance for inspection, installation, testing, and adjustment of the equipment located in 1.2 and identified in 1.3”.

• Contractor notes that there is no OEM technical representative identified within the body of the specification as written.

• Contractor notes that the references provided are not preparatory thus no OEM technical representative should be required.

QUESTION: Can the Customer provide clarification as the disparities identified above regarding the requirements of paragraphs 3.1 and 3.1.1 invoking the need for a OEM technical representative and to whom would they direct all bidders to solicit and obtain such services from and will an Amendment be issued providing a revised specification?

GOVERNMENT RESPONSE:

Addressed ERRATA 2 CG 63.

Delete Para 3.1 and 3.1.1

TITLE: Oily Water Separator Pump and Motor Assemblies; install
PARA. NO:
PAGE NO:

ITEM NO: 432-12-003 CONTRACTOR QUESTION 134: Para 1.3.1 - 2 "L" Tubes to be replaced, Para 3.4 is to test SP Phone circuits at completion, After reviewing Drawings contractor could not fined the SP Cabling requiring a Size "L" Stuffing Tube, Contractor request Gov to provide Circuit ID and Cable Type for this work item. GOVERNMENT RESPONSE:

Addressed ERRATA 3 CG 64: Corrected reference.

TITLE: Kickpipe; replace
PARA. NO: 1.3.1 & 3.4
PAGE NO: 1

ITEM NO: 521-11-005 CONTRACTOR QUESTION 142: Paragraph 3.2 states “(V)(G) "OPERATIONAL TEST" “Accomplish the requirements of 009-52 of 2.1 for relief valve listed in 1.3.2, using clean fresh water and lifting pressure of 140 PSI”.

• Contractor notes that NAVSEA Standard Item 009-52 Relief Valve; repair leads to the conclusion that the existing Valve listed in 1.3.2 should be overhauled and turned over to the Customer.

• Contractor notes paragraph 3.2 of the specification as written is unclear if an overhaul of the existing Relief Valve listed in 1.3.2 IAW NSI 009-52 is required or if the intention was to accomplish NSI 009-71 Hydro Test of the new equipment listed in 5.1 item 2 using clean fresh water and lifting pressure of 140 PSI .

QUESTION: Can the Customer provide clarification as to the disparities identified above regarding the requirements of paragraph 3.2 and will an Amendment be issued providing a revised specification?

GOVERNMENT RESPONSE:

Accomplish the requirements of 009-52 Para's 3.5 and 3.6 of 2.1 for relief valve listed in 1.3.2, using clean fresh water and lifting pressure of 140 PSI”

TITLE: Firemain Reducing Station 18; repair
PARA. NO:
PAGE NO: