This document is an architectural HVAC piping plan for an attic floor, specifically for the Department of Veterans Affairs (VA) infrastructure project at the Dayton VAMC. The detailed technical drawing shows piping configurations for multiple Fan Coil Units (FCUs) across different phases, with pipe sizes ranging from 0.75" to 1.5" for various systems including CHR (Chilled Hot Return), CHS (Chilled Hot Supply), HWR (Hot Water Return), and HWS (Hot Water Supply). The plan includes specific notations for Phase 2 and Phase 4, and features multiple equipment connections such as 408-ERV1, 408-ERV2, and 408-PH2. The drawing is prepared by Heapy Engineering and Guidon Design Inc., with a project number 2018-05164, and is part of a solicitation (36C25025B0036AMEND0002) for infrastructure deficiencies correction at the Dayton VA Medical Center, with a bid opening date of July 23, 2025.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FCU-70
FCU-56
FCU-53
FCU-54
FCU-55
FCU-57
FCU-62
FCU-63
FCU-64
FCU-33
FCU-35 FCU-43
FCU-44
FCU-58
FCU-59
FCU-63
FCU-61
FCU-60
FCU-51
FCU-49
FCU-48
FCU-52
FCU-38
FCU-32
FCU-37
FCU-34
F C
U -3
FCU-41
FCU-40
FCU-42 FCU-45
FCU-46
FCU-47
FCU-50
HWS
CHS
HWR
CHR
1.5" - HWR
1.5" - HWS
1.5" - CHR
1.5"1.5"
1.25"1.25"
1.25"1.25"
1.25"1.25"
1" 1"
FCU-69FCU-39
1.25"1.25"
1.5"1.5"
3" DN
3" DN
3" DN
ALL SYSTEMS
FCU-67
1.5" - CHS
1" - HWR
1" - HWS
1" - CHS
1" - CHR
1" - CHR
1" - CHS
1" - HWS
1" - HWR
1.25" - CHR
1.25" - CHS
1.25" - HWR
1.25" - HWS
0.75"0.75"
1"1"
1"1"
CHR
CHS
HWR
HWS
H W
S H
W R
C H
S C
H R
1.25"1.25"
1"1"
1.5"1.5"
1.25"
1.25"1.25"
1"1"
CHR
CHS HWR
HWS
1"1"
1.25"1.25"
1"1"
0.75"0.75" 0.75"0.75"
1"1"
1"1" 0.75"0.75"
1.25" - D
1.5" - D
1" - D
1.
5"
D
1"
D
1.
D
1.25" - D1.25" - D
1.
D
PHASE 2
PHASE 3PHASE 4
1.5" D DN 1.5" D DN1.
D
408-ERV1
1"1" 0.75"0.75"
408-ERV2
408-ERV3
1.5" - CHR
1.5" - CHS
1.5" - HWS
1.5" - HWR
408-PH3
408-CC3
408-PH2
408-CC2
408-PH2
408-CC2
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204
317.800.6388 | WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
PROJECT NO. STATE COA FIRM NO.2018-05164 01528
/9
/2
:2
:3
P M
MP103
ATTIC FLOOR PLAN - PIPING CORRECT
INFRASTRUCTURE
DEFICIENCIES, B408
DAYTON, OHIO 45428
552-19-102
PHIL WEST, COR
May 2nd, 2025 GSE WJS
BID DOCUMENTS
FULLY SPRINKLERED
GENERAL NOTES
PLAN NOTES
SCALE: 1/8" = 1'-0"
ATTIC-HVAC-PIPING
1N
A. REFER TO SHEET M001 FOR LEGEND, ABBREVIATIONS, INDEX OF DRAWINGS,
AND ADDITIONAL GENERAL NOTES.
B. HEATING AND CHILLED WATER CONNECTIONS TO FIN TUBE AND FAN COIL
UNITS TO BE 0.75" UNLESS OTHERWISE NOTED.
A. REFER TO SHEET M001 FOR LEGEND, ABBREVIATIONS, INDEX OF DRAWINGS,
AND ADDITIONAL GENERAL NOTES.
B. HEATING AND CHILLED WATER CONNECTIONS TO FIN TUBE AND FAN COIL
UNITS TO BE 0.75" UNLESS OTHERWISE NOTED.
1. NOTE OMITTED.
Revisions: Date:
ADDENDUM #1 07/09/2025
| Sheets |
| M601 - SCHEDULES |
| M602 - SCHEDULES |
| M603 - SCHEDULES |
| M701 - CONTROLS AND AUTOMATION |
| MD100 - BASEMENT FLOOR PLAN - REMOVALS |
| MD101 - FIRST FLOOR PLAN - REMOVALS |
| MD102 - SECOND FLOOR PLAN - REMOVALS |
| MD103 - ATTIC FLOOR PLAN - REMOVALS |
| MP100 - BASEMENT FLOOR PLAN - PIPING |
| MP101 - FIRST FLOOR PLAN - PIPING |
| MP102 - SECOND FLOOR PLAN - PIPING |
| MP103 - ATTIC FLOOR PLAN - PIPING |