MP101 - FIRST FLOOR PLAN - PIPING.pdf
PDF 588 KB Posted
- Solicitation number
- 36C25025B0036AMEND0002
About this file
This document is a first floor piping plan (MP101) for a Veterans Affairs Medical Center (VAMC) infrastructure improvement project located in Dayton, Ohio. The detailed engineering drawing shows a comprehensive piping layout for a multi-phase facility renovation, featuring numerous mechanical room zones, offices, and support spaces. The plan includes specific piping annotations with detailed pipe sizes ranging from 0.75" to 4" for various systems like hot water supply (HWS), hot water return (HWR), chilled water supply (CHS), and chilled water return (CHR), with multiple fan coil units (FCU) strategically positioned throughout the floor plan.
The project is associated with Solicitation Number 36C25025B0036AMEND0002, with a bid opening date of July 23, 2025, at 10:00 a.m. local time at the Network Contracting Office 10 in Kettering, OH. The infrastructure deficiencies project is being managed by the Department of Veterans Affairs Veterans Health Administration, specifically Veterans Integrated Service Network 10, with design work completed by Guidon Design Inc. and engineering services by Heapy. The drawing is marked as fully sprinkled and includes multiple construction phases (Phase 2, Phase 3, Phase 4), indicating a complex, staged renovation approach for the medical facility.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
T
T T
T
TT
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
TT
T
T
T
T
T
T
408-BT1
FCU-28
FCU-27
FCU-29
FCU-30
FCU-31
FCU-16
F C
U -2
FCU-25 FCU-26
FCU-18
FCU-13
FCU-10A
F C
U -7
F C
U -2
F C
U -1
A
F C
U -6
F C
U -3
FCU-15
FCU-14
FCU-22
FCU-21
FCU-20 FCU-19
FCU-17
FCU-12
FCU-11
FCU-10FCU-9FCU-8
FCU-4
FCU-5
FCU-23A FCU-23B
FCU-23C FCU-23D
FT-5'-0" FT-5'-0" FT-5'-0" FT-5'-0" FT-5'-0"
FCU-5A FCU-5B
FT-4'-0"
FT-6'-0"
FT-6'-0"
FT-4'-0"
FT-4'-0"
FT-6'-0"
FT-6'-0"
FT-4'-0"
FT-3'-0"
FT-5'-0" FT-5'-0" FT-5'-0" FT-5'-0"
FT-5'-0"
FT-4'-0"
FT-5'-6"
FT-5'-6"
FT-5'-6"
FT-6'-0"
FT-6'-0"
FT-4'-0"
FT-5'-0"
FT-5'-0"
FT-4'-0"
FT-5'-0"
FT-4'-0"
FT-5'-0"
FT-5'-0"
FT-4'-0"FT-4'-0"FT-4'-0"
FT-4'-0"FT-5'-0"
FT-5'-0"FT-5'-0"
FT-5'-0"
FT-4'-0"FT-5'-0"FT-4'-0"
FT-5'-0"
FT-8'-6"
FT-8'-6"
FT-5'-0"
FT-4'-0"
FCU-27A FCU-27B
CHR
HWR
CHS
HWS
FT-5'-0" FT-5'-0"
1.5" 1.5" 1.5" 1.5"
2"2"2" 2"
408-ACCH2 408-ACCH1408-ACCH2 408-ACCH1408-ACCH2
CHR4"4"
4"
4" 4"
0.75" DN
0.75" UP
0.75" UP
0.75" DN
0.75" UP
0.75" UP
FT-10'-0"
FT-10'-0"
FT-8'-0"
FT-10'-0"
FT-9'-6"
FT-9'-6"
F C
U -2
1"
1.
1.
1.5"1.5"
1" 1"
2"2"
1" 1"
1.25" 1.25"
1.
1.
1.5" 1.5"
1" 1"
1" 1"
1" 1"
1.
5"
1.
5"
1" 1"
1.5"1.5"
1.
1.
1.25"1.25"
1" 1"
2" 2"
1.
" 1.
1" 1"
1" 1"
1.25" 1.25" 1" 1"
1.
1.
2"2" 1.5" 1.5" 1" 1"
1" 1"
1.5" 1.5"1" 1"
1"1"
1" DN
1"1"
1" DN
1" 1"
1" 1"
1" 1"
1.
1.
1" 1"
1.25" 1.25" 1" 1"
2" 2"
2" 2"
1" 1"
1" 1"
1" 1"
1.
1.
1.5" 1.5" 1.5"
1.5"
1" 1" 1.
" 1.
1.
2" 2"
3" UP, 4" DN
ALL PIPING
SYSTEMS
1" 1"
H W
R H
W S
1.
1.
1" 1"
1"
0.
0.
0.75" UP (TYP.)
107d
OFC
107e OFC 107f
CONFERENCE
107b
OFC
107c
OFC
107g
OFFICE
107a
OFFICE
106f
OFFICE
106e
OFFICE
106g OFFICE 106h
OFFICE
106d
STORAGE
106c
COPIER
106j
OFFICE
DSS SUITE
106k
OFFICE
106l
OFFICE
106b
OFFICE
106a
OFFICE
KITCHEN
Room
103B
COMM.
MENS
TELE
PHARMACY
103C
CONFERENCE
103D
OFFICE104
OFFICE
103A
OFFICE
101C
OFFICE
101A
OFFICE
101A
OFFICE
ACQUISITION
CHAPLAIN
101D
OFFICE
100c OFFICE100d
OFFICE
Space
100m
OFFICE
100g
OFFICE
100n
OFFICE
100k
OFFICE
100h
OFFICE
100l
OFFICE
100j
OFFICE
WOMENS
101B
COMM
109A
BREAK
ROOM
109C
OFFICE
2"
0.75"
HWS/HWR UP
(TYP.)
0.75"
HWS/HWR UP
(TYP.)
0.75"
HWS/HWR UP
(TYP.)
1"CHS/CHR
1" CHS/CHR
1"CHS/CHR
1"CHS/CHR
0.75"
HWS/HWR UP
(TYP.)
1"CHS/CHR
3" UP, 4" DN
ALL PIPING
SYSTEMS
3" UP, 4" DN
ALL PIPING
SYSTEMS
0.75"
HWS/HWR UP
(TYP.)
FT-4'-0"
0.75"
HWS/HWR UP
(TYP.)
1" 1"
FCU-1B
1"
D
1.25" - D
1" - D
1" - D
1.25" - D
1.25" - D 1" - D
1.25" - D
1" - D
1.
D
1.5" - D
1.
D
1" - D
1.5" - D
AC-1AC-2
CU-3
CU-2
CU-1
PHASE 2
PHASE 3PHASE 4
UP
DN
UP
ELEV
1.5" - D
1.5" - D
1 .
5 "
D
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204
317.800.6388 | WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
PROJECT NO. STATE COA FIRM NO.2018-05164 01528
/9
/2
:2
:3
P M
MP101
FIRST FLOOR PLAN - PIPING CORRECT
INFRASTRUCTURE
DEFICIENCIES, B408
DAYTON, OHIO 45428
552-19-102
PHIL WEST, COR
May 2nd, 2025 GSE WJS
BID DOCUMENTS
FULLY SPRINKLERED
GENERAL NOTES
PLAN NOTES
SCALE: 1/8" = 1'-0"MP101
1 FIRST FLOOR PLAN - NEW WORK
N
A. FIELD VERIFY LOCATIONS FOR ALL EXTERIOR EQUIPMENT AND CONCRETE
PADS WITH COR.
B. HEATING AND CHILLED WATER CONNECTIONS TO FIN TUBE AND FAN COIL
UNITS TO BE 0.75" UNLESS OTHERWISE NOTED.
C. REFER TO SHEET M001 FOR LEGEND, ABBREVIATIONS, INDEX OF DRAWINGS,
AND ADDITIONAL GENERAL NOTES.
1. NOTE OMITTED.
2. EXTEND 2" DRAIN DOWN TO MOP BASIN. INDIRECT DRAIN WITH 45° CHAMFER.
3. EXTEND REFRIGERANT PIPING AND DRAIN FROM AC-3 ON SECOND FLOOR.
REFER TO SHEET MP102 FOR CONTINUATION.
4. PROVIDE REFRIGERANT PIPING AND SPECIALTIES PER MANUFACTURERS
RECOMMENDATIONS. APPROXIMATE ROUTE SHOWN.
5. PROVIDE CONCRETE PAD. MAINTAIN MANUFACTURERS RECOMMENDED
CLEARANCES.
6. PROVIDE PVC PIPE ENCLOSURE TO CONCEAL VERTICAL PIPING. MATCH
BUILDING COLOR.
Revisions: Date:
ADDENDUM #1 07/09/2025
| Sheets |
| M601 - SCHEDULES |
| M602 - SCHEDULES |
| M603 - SCHEDULES |
| M701 - CONTROLS AND AUTOMATION |
| MD100 - BASEMENT FLOOR PLAN - REMOVALS |
| MD101 - FIRST FLOOR PLAN - REMOVALS |
| MD102 - SECOND FLOOR PLAN - REMOVALS |
| MD103 - ATTIC FLOOR PLAN - REMOVALS |
| MP100 - BASEMENT FLOOR PLAN - PIPING |
| MP101 - FIRST FLOOR PLAN - PIPING |
| MP102 - SECOND FLOOR PLAN - PIPING |
| MP103 - ATTIC FLOOR PLAN - PIPING |
File details come from the government source that posted it. Updated .