This document is a draft technical drawing for a Hydraulic Mount Assembly, part number MALF-601, created by G2 Engineering Consulting on 10/26/2022. The technical drawing provides detailed schematics and specifications for a hydraulic mount with precise dimensional measurements, including a top-down view, side view, and exploded assembly diagram.
The technical drawing includes critical manufacturing notes specifying material certification requirements, welding standards, and non-destructive testing protocols. The bill of materials lists five component types, including a hydraulic mount weldment (MALF-907), Grade 8 steel flat washers, heavy hex cap screws, shoulder bolts, and hex heavy nuts. Specific technical requirements include adherence to ABS material certification rules, AWS welding standards, and comprehensive non-destructive testing of critical welds, including 100% volumetric testing of butt welds and surface testing of fillet welds. The drawing is marked as a draft and contains confidential information not to be distributed without consent.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| MALF-901-A_B (Draft).PDF | ||
| MALF-911 (Draft).pdf | ||
| MALF-600 (Draft).pdf | ||
| MALF-908 (Draft).pdf | ||
| MALF-604 (Draft).pdf | ||
| MALF-602 (Draft).pdf | ||
| MALF-105 (Draft).pdf | ||
| MALF-104 (Draft).pdf | ||
| MALF-902 (Draft).pdf | ||
| MALF-910 (Draft).pdf | ||
| REQUEST FOR INFORMATION (RFI) - ACM LIFTING FRAMES.pdf | ||
| MALF-903-A_B (Draft).pdf | ||
| MALF-100-101-102-103 (Draft).pdf | ||
| MALF (Draft).pdf | ||
| MALF-912 (Draft).pdf | ||
| MALF-606 (Draft).pdf | ||
| MALF-907 (Draft).pdf | ||
| MALF-603 (Draft).pdf | ||
| MALF-906 (Draft).pdf | ||
| MALF-909 (Draft).pdf | ||
| MALF-605 (Draft).pdf |
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
6-3/8"
35.74 1.407
197.66 7.782
654.30 25.760
9"
NOTE:
UNLESS OTHERWISE SPECIFIED ALL MATEIRALS USED IN CONSTRUCTION OF COMPONETNS ARE TO HAVE ABS MATERIAL CERTIFICATION IN ACCORDINATE WITH THE •
APPLICAPLE SECIONS OF "ABS RULES FOR MATERIALS AND WLEDING (PART 2)"
MATERIALS ARE TO BE FURNISHED WITH CERTIFICATES ISSUED BY THE MILL OR MATERIAL MANUFACTURER, INDICATING, AS A MINIMUM AND AS APPLICABLE, THE • MATERIAL SPECIFICATION, GRADE, PROCESS OF MANUFACTURE, HEAT TREATMENT DETAILS, MECHANICAL AND CHEMICAL PROPERTIES, IDENTIFICATION NUMBERS, AND
TEST RESULTS.
ALL WELDING SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF AWS D1.1 "STRUCTURAL WELDING CODE - STEEL"• ALL WELDS SHALL BE TESTED USING EITHER VOLUMETRIC RADIOGRAPHIC TESTING (RT) OR ULTRASONIC TESTING (UT) METHODS OR SURFACE NDT TECNIQUES INCLUDING • MAGNETIC PARTICLE INSPECTION (MPI), PENETRANT TESTING (PT), EDDY CURRENT (EC) OR ALTERNATING CURRENT FIELD MEASURMENT (AFCM) CRITICAL WELDS ARE TO BE SUBJECTED TO THE FOLLOWING NONDESTRUCTIVE TESTING TO THE SATISFACTION OF THE ATTENDING SURVEYOR PRIOR TO PROOF LOAD •
TESTING:
100% VOLUMETRIC NDT OF ALL CRITICAL BUTT WELDS•
100% SUFACE NDT ON BOTH SIDES OF CRITICAL FILLET WELDS•
DRAWN BY:
THE INFORMATION CONTAINED IN THIS DRAWING IS CONSIDERED
CONFIDENTIAL. CONTENT SHOULD NOT BE DISTRIBUTED WITHOUT CONSENT
DIMENSIONS ARE IN INCHES
TOLERANCES:
ANGULAR: MACH .5 DEG
ONE PLACE DECIMAL .05
TWO PLACE DECIMAL .01
THREE PLACE DECIMAL .005
MATERIAL
SEE NOTES
SIZE
B
PART NUMBER: REV
UNLESS OTHERWISE SPECIFIED
SHEET 1 OF 2
MALF-601
DO NOT SCALE
HYDRAULIC MOUNT, ASSEMBLYG2 ENGINEERING
CONSULTING
FINISH
SEE NOTES
CREATED:
Marc.Dickinson
10/26/2022
A A
B B
C C
D D
DRAFT
NOTE:
UNLESS OTHERWISE SPECIFIED ALL MATEIRALS USED IN CONSTRUCTION OF COMPONETNS ARE TO HAVE ABS MATERIAL CERTIFICATION IN ACCORDINATE WITH THE •
APPLICAPLE SECIONS OF "ABS RULES FOR MATERIALS AND WLEDING (PART 2)"
MATERIALS ARE TO BE FURNISHED WITH CERTIFICATES ISSUED BY THE MILL OR MATERIAL MANUFACTURER, INDICATING, AS A MINIMUM AND AS APPLICABLE, THE • MATERIAL SPECIFICATION, GRADE, PROCESS OF MANUFACTURE, HEAT TREATMENT DETAILS, MECHANICAL AND CHEMICAL PROPERTIES, IDENTIFICATION NUMBERS, AND
TEST RESULTS.
ALL WELDING SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF AWS D1.1 "STRUCTURAL WELDING CODE - STEEL"• ALL WELDS SHALL BE TESTED USING EITHER VOLUMETRIC RADIOGRAPHIC TESTING (RT) OR ULTRASONIC TESTING (UT) METHODS OR SURFACE NDT TECNIQUES INCLUDING • MAGNETIC PARTICLE INSPECTION (MPI), PENETRANT TESTING (PT), EDDY CURRENT (EC) OR ALTERNATING CURRENT FIELD MEASURMENT (AFCM) CRITICAL WELDS ARE TO BE SUBJECTED TO THE FOLLOWING NONDESTRUCTIVE TESTING TO THE SATISFACTION OF THE ATTENDING SURVEYOR PRIOR TO PROOF LOAD •
TESTING:
100% VOLUMETRIC NDT OF ALL CRITICAL BUTT WELDS•
100% SUFACE NDT ON BOTH SIDES OF CRITICAL FILLET WELDS•
ITEM
NO. PART NUMBER QTY. DESCRIPTION
1 MALF-907 1 Hydraulic Mount Weldment
2 98025A036 16 3/4" FLAT WASHER, GRADE 8 STEEL
3 STOCK 12 3'4-10 X 2.0in HEAVY HCS
4 91259A844 2 3'4 SHOULDER X 5`8-11 THREAD -
2.25in, ALLOY STEEL
5 STOCK 2 5'8"-11 HEX HEAVY NUT
DRAWN BY:
THE INFORMATION CONTAINED IN THIS DRAWING IS CONSIDERED
CONFIDENTIAL. CONTENT SHOULD NOT BE DISTRIBUTED WITHOUT CONSENT
DIMENSIONS ARE IN INCHES
TOLERANCES:
ANGULAR: MACH .5 DEG
ONE PLACE DECIMAL .05
TWO PLACE DECIMAL .01
THREE PLACE DECIMAL .005
MATERIAL
SEE NOTES
SIZE
B
PART NUMBER: REV
UNLESS OTHERWISE SPECIFIED
SHEET 2 OF 2
MALF-601
DO NOT SCALE
HYDRAULIC MOUNT, ASSEMBLYG2 ENGINEERING
CONSULTING
FINISH
SEE NOTES
CREATED:
Marc.Dickinson
10/26/2022
A A
B B
C C
D D
DRAFT
| Weldment |
| Drawing View1 |
| Drawing View3 |
| Drawing View4 |
| Drawing View5 |
| BOM |
| Drawing View2 |
File details come from the government source that posted it. Updated .