This document provides details for a federal construction solicitation to replace the sprinkler system, HVAC units, and communication cabling at the Peach Springs Health Center in Peach Springs, Arizona. The solicitation seeks a single firm fixed price contract to furnish all labor, materials, equipment, permits, insurance and supervision for the replacement work. The construction magnitude is estimated between $1 million to $5 million. The period of performance is 365 calendar days from notice to proceed. Interested offerors must register in the System for Award Management to be considered for award. The closing date and other submission details will be provided in the full solicitation. The Indian Health Service intends to use lowest price technically acceptable evaluation criteria to award the contract as a request for proposal in accordance with FAR Part 36 procedures.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Space
Approximate
Size (SF) Notes
Size is based on two rooms from the DOD
Whole Building Design Guide (WBDG) template DNTG3:
https://www.wbdg.org/FFC/DOD/MHSGP/AR
CHIVES/ppmd_templates_dntg3.pdf
Include wire shelving for storage. Bottom shelves must have a solid surface to protect items stored on the bottom.
Size is based on template DNSC4 from DOD's
WBDG:
https://www.wbdg.org/FFC/DOD/MHSGP/pp md_templates_DNSC4.pdf
112.5
One mens' room and one ladies' room each at 7.5' x 7.5'
One mens' room and one ladies' room each at 10' x 10'
120 Include system furniture as necessary
Dental air compressor and dental vacuum must be indoors
Sized to maintain 6' separation plus a little extra
Include desk area for staff to work and receive patients as necessary
80 A minimum of one JC is required.
4‐chair Dental Treatment Room
Supply storage
Processing Area with sink
Public Restrooms
Staff Restrooms with lockers Staff Office
Mechanical Rooms
Waiting Area for 5 people
Reception office
Corridors
Janitor's Closet
Sterilization Area 180
Size is based on template DNSC5 from DOD's
WBDG:
https://www.wbdg.org/FFC/DOD/MHSGP/AR
CHIVES/ppmd_templates_DNSC5_2015.pdf
Total minimum square footage 1813.5
Peach Springs Dental Swing Space minimum rooms needed
Attachment J01e - Dental Swings Space Needs
Peach Springs Replace Sprinkler System, HVAC, and Communication Cabling Page 1 of 2
Equipment Manufacturer Model
Amalgam Separator Solmetex HG5‐001
Monitor, Physiologic, Vital Signs, w/Stand WELCH ALLYN 75CT‐B / 7000‐MS3
Undercounter refrigerator Helmer iPR105‐GX
Washer/Disinfector Miele 5425
Hand sanitizer dispenser Purell LTX‐12
Hand soad dispenser GOJO LTX‐12
New Contractor‐provided,Contractor‐installed Equipment needed in swing space