This document provides details for a federal construction solicitation. The Indian Health Service is seeking a contractor to replace the existing failed dry-pipe sprinkler system with a new wet-pipe sprinkler system, replace outdated HVAC units, and replace communication cabling at the Peach Springs Health Center in Peach Springs, Arizona under solicitation number 75H701-23-R-00048. The work must be completed within 365 calendar days of the notice to proceed. The construction project is valued between $1,000,000 and $5,000,000 and will be awarded as a single firm fixed price contract determined by lowest price technically acceptable evaluation criteria. Offerors must register in the System for Award Management to be considered and check for any solicitation amendments on the website, as hard copy documents will not be provided.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A0.0 TITLE SHEET
| A0.1 OCCUPANCY CALC & EXIT PLAN |
| A1.0 AREA PLAN |
| A1.1 SITE PLAN |
| A1.2 ENLARGES SITE PLAN & DETAILS |
| A2.0 CLINIC OVERALL FLR PLAN |
| A2.1 CLINIC WEST WING FLR PLAN |
| A2.2 CLINIC LOBBY FLOOR PLAN |
| A2.3 CLINIC NORTH WING FLR PLAN |
| A2.4 CLINIC RM & FLR FINISH PLAN |
| A2.5 CLINIC WEST W ING & CEILING PLAN |
| A2.6 CLINIC LOBBY CEILING PLAN |
| A2.7 CLINIC NORTH WING CEILING PLAN |
| A2.8 CLINIC WEST W ING EQUIP PLAN |
| A2.9 CLINIC LOBBY EQUIP PLAN |
| A2.10 CLINIC NORTH WING EQUIP PLAN |
| A2.11 CLINIC ROOF PLAN |
| A2.12 MAINT FLOOR CEILING & ROOF PLANS |
| A3.0 CLINIC EXT ELEVATIONS |
| A3.1 MAINTENANCE ELEVATIONS & WALL SECTIONS |
| A4.0 CLINIC BUILDING SECTIONS |
| A4.1 CLINIC CANOPY PLANS |
| A4.2 CLINIC WALL SECTIONS |
| A4.3 CLINIC WALL SECTIONS |
| A4.4 CLINIC WALL SECTIONS |
| A4.5 CLINIC WALL SECTIONS |
| A5.0 CLINIC INT ELEVATIONS |
| A5.1 CLINIC INT ELEVATIONS |
| A5.2 CLINIC INT ELEVATIONS |
| A5.3 CLINIC INT ELEVATIONS |
| A6.0 CLINIC DOOR SCHEDULE |
| A6.1 CLINIC DOOR & WINDOW TYPES |
| A6.2 BOTH DOOR & WINDOW DETAILS |
| A7.0 BOTH ARCH DETAILS |
| A7.1 BOTH ARCH DETAILS |
| C1 PAVING & GRADING PLAN |
| C2 WATER & SWER PLAN |
| S1.0 GENERAL STRUCTURAL NOTES |
| S1.1 TYPICAL DETAILS |
| S1.2 BEAM COLUMN & FOOTING SCHEDULES |
| S2 CLINIC FOUNDATION PLAN |
| S3 CLINIC ROOF FRAMING PLAN |
| S4 MAINT FOUND & FRAM PLAN |
| S5 FOUNDATION DETAILS |
| S6 FRAMING DETAILS |
| M1 CLINIC WEST WING HVAC PLAN |
| M2 CLINIC LOBBY HVAC PLAN |
| M3 CLINIC NORTH WING HVAC PLAN |
| M4 MAINTENANCE HVAC PLAN SCHEDULES |
| P1 CLINIC PLUMBING PLAN |
| P2 MAINT PLUMB PLAN SCHED |
| P3 CLINIC ISOMETRIC DIAGRAMS |
| E1.0 SITE LIGHTING PLAN |
| E2.0 LIGHTING PLAN WEST WING |
| E3.0 LIGHTING PLAN NORTH WING |
| E4.0 POWER PLAN WEST WING |
| E5.0 POWER PLAN NORTH WING |
| E6.0 LIGHTING & POWER PLANS LOBBY |
| E7.0 PANEL SCHEDULES |
| E8.0 EQUIP SCHED & SYMBOLS LEGEND |
| E9.0 MAINT LIGHTING PLAN & SCHED |
| L1 LANDSCAPE PLAN |
| L2 IRRIGATION PLAN |