J.32 Phase I Relevant Corporate Experience Form_10.27.25.docx

DOCX document 43 KB Posted

Attached to
Power Systems Design & Install 2
Solicitation number
6973GH-26-R-00018
Issued by

About this file

This document is an attachment (J.32) for a Relevant Corporate Experience Form for a Federal Aviation Administration (FAA) power systems design and installation contract. The form requires offerors to demonstrate technical capability by providing three completed contracts within the past five years across six specific project classifications: engine generators (20+ kW), uninterruptible power supplies (40+ kVA), fuel storage tank systems, underground electrical cabling, alternative energy systems (1+ kW), and lightning protection/grounding systems.

Contractors must also demonstrate geographic support experience by showing service capabilities across at least three CONUS regions and one OCONUS location. The solicitation (6973GH-26-R-00018) is a pre-solicitation for a firm fixed-price contract with NAICS code 238210, targeting power systems design and installation services. Potential bidders must be registered in the System for Award Management (SAM) and may submit questions via email. The FAA reserves the right to review program eligibility and communicate with offerors during the solicitation process, with the ultimate goal of awarding a standalone contract for power systems design and installation services.

View the file

Other files

File Type Posted
6973GH-26-R-00018_DRAFT.pdf PDF
J.01 Statement of Work 12.01.25.pdf PDF
J.04 Government Furnished Equipment (GFE).pdf PDF
J.07 Performance Bond - FAA Form Number FAA 4400-63.pdf PDF
J.11 FAA-C-1217H Chg 2.pdf PDF
J.17 FAA Order 1050.10D.pdf PDF
J.24 FST Program Specifications.pdf PDF
J.29 6980_37 Maintenance of Solar Photovoltaic System.pdf PDF
J.33 PSDI II Technical Approach Evaluation Worksheets.xlsx XLSX spreadsheet
J.02 Contract Data Requirements List (CDRL).pdf PDF
J.09 Pre-Construction Installation EOSH Checklist - FAA Form 3900-18.pdf PDF
J.12 FAA-C-1391e INSTALLATION TERMINATION SPLICING AND TRANSIENTSURGE PROTECTION OF UNDERGROUND ELECTRICAL DISTRIBUTION SYSTEM POWER CABLES.pdf PDF
J.13 FAA-D-2494B.pdf PDF
J.14 faa-std-002H.pdf PDF
J.15 FAA-STD-019G.pdf PDF
J.20 FAA Order 6950_27B.pdf PDF
J.25 FAA Order 1370.121B - FAA Information Security and Privacy Policy.pdf PDF
J.36 Schedule B, Price Proposal PSDI II Cost Worksheet_10.28.2025.xlsx XLSX spreadsheet
J.35 Phase 2 Technical Approach - Factor 2, Installation Proposal Form .docx DOCX document
J.03 Data Item Description (DID).pdf PDF
J.05 6010-5 CAI Form.pdf PDF
J.06 Travel Authorization Form.xlsx XLSX spreadsheet
J.10 Pre-Construction Agenda and Checklist - DOT Form F4220.3.doc DOC document
J.18 FAA Order JO_3900_57A_W-CHG_1_Inc.pdf PDF
J.19 FAA Order JO 3900.64A - Air Traffic Organization Electrical SafetyProgram.pdf PDF
J.21 FAA Order JO 1050 17B.pdf PDF
J.22 FAA Order JO_6950_2F .pdf PDF
J.23 FST Guidelines.pdf PDF
J.30 LPGBS Checklist.xls XLS spreadsheet
J.31 Contractor Release DOT 4220.4 (1).pdf PDF
J.00 Index.pdf PDF
J.08 Payment Bond - FAA Form Number 4400-61.pdf PDF
J.16 FAA-STD-032.pdf PDF
J.26 FAA-E-99001 - Photovoltaic Specification.pdf PDF
J.27 FAA-STD-061.pdf PDF
J.28 FAA Order 6980_36 Maintenance of Hydrogen Fuel Cells.pdf PDF
J.34 Phase 2 Technical Approach - Factor 1, Design Proposal Form .docx DOCX document
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment J.32 Relevant Corporate Experience Attachment J.32– Relevant Corporate Experience:

Offeror must submit this form, Relevant Corporate Experience, addressing the following and per the below instructions:

· Offerors may reference the same contract (A, B, C) for multiple citations in question 8.

· This J.32 Submission must be an independent PDF with no other attachments.

· Estimated Value on this form refers to the example contracts submitted for Relevant Corporate Experience and should make no reference to cost associated with this SIR proposal.

· If work was performed on a specific Task Order, site both the Task Order number and the Base/Parent Contract number should be referenced.

Factor 1 – Scope:

The Offeror must demonstrate scope for Relevant Corporate Experience, provide no more than three (3) completed contracts/projects, within five (5) years of the issuance of this SIR. The Offeror must provide three (3) different types of design and/or installation projects from the following six (6) classifications; of which a minimum of one (1) submissions must be for an installation project.

Yes
No
Project Classification
☐
☐
1. Engine Generator (EG), 20 kW or larger.
☐
☐
2. Uninterruptible Power Supplies (UPS), facility size 40 kVA or larger.
☐
☐
3. Fuel Storage Tank (FST) Systems, 250 gallon tank or larger with environmental monitoring.
☐
☐
4. Underground cabling (direct buried) for Electrical Line Distribution (ELD) of a minimum of 1,000 feet, to include splicing and terminations OR

Direct burial of low voltage conduit systems, installation of handholes with 500 feet of low voltage circuits to include termination.

☐
☐
5. Alternative Energy Systems (AES) such as

photovoltaic/solar, wind power, fuel cells and other emerging alternative energy technologies. AES system, 1kW or larger.

☐
☐
6. Lightning Protection, Grounding, Bonding and Shielding (LPGBS). There are five main components of LPGBS work: (1) exterior lightning protection systems, (2) earth electrode system (EES), (3) sensitive electronic equipment grounding systems, (4) surge protection, and (5) fences and gates grounding. LPGBS Project submission must include three (3) of the five (5) main components.

If you have selected yes for any of the above project classifications, you will be required to fill out the project classification form relevant to that project and provide additional project information and details. Project classification forms provided in this document proceeding the vendor information section.

Factor 2 – Geographic Support Experience:

The Offeror must demonstrate their Geographic Support Experience by completing SIR attachment J.32 - Factor 2. The Offeror must indicate with an “X” or check mark the region(s) or location(s) listed below where the Offeror’s has experience in providing services similar to the requirements described in the SOW.

The Offeror must demonstrate experience supporting at least three (3) Continental United States (CONUS) regions and at least one (1) Outside Continental United States (OCONUS) region or location. (https://www.faa.gov/airports/regions).

CONUS:

☐ Central Region (IA, KS, MO, NE) ☐ Eastern Region (DC, DE, MD, NJ, NY, PA, VA, WV) ☐ Great Lakes Region (IL, IN, MI, MN, ND, OH, SD, WI) ☐ New England Region (CT, MA, ME, NH, RI, VT) ☐ Northwest Mountain Region (CO, ID, MT, OR, UT, WA, WY) ☐ Southern Region (AL, FL, GA, KY, MS, NC, SC, TN) ☐ Southwest Region (AR, LA, NM, OK, TX) ☐ Western-Pacific Region (AZ, CA, NV)

OCONUS:

☐ Alaskan Region ☐ Hawaii ☐ Saipan ☐ Guam ☐ Caribbean Islands ☐ Puerto Rico ☐ American Samoa ☐ Marshall Islands

This form can be completed on government and/or commercial sector installations. Scope may be represented on one contract/project or be represented on separate contract(s)/ project(s) providing same or similar services; within five (5) years of the issuance of the SIR. Offeror must not use more space than provided and must not modify the form in anyway.

Block 2 must be completed with only one email address and be for the individual authorized to communicate on behalf of the Offeror.

Vendor Information:

1. Offeror/Vendor Name:

2. Offeror/Vendor Email Address:

3. Contract Number(s):
A

B

C

4. Issuing Office:
A

B

C

5. Total Estimated Value of the Contract/Projects (s):
A

B

C

6. Period of Performance(s):
A

B

C

7. Place(s) of Performance:
A

B

C

8. Factor 1: Scope - The information provided in this Block must reference the information submitted in Blocks 3 through 7. Provide no more than three (3) completed contracts/projects, within five (5) years of the issuance of this SIR. The Offeror must provide three (3) different types of design and/or installation projects from the following six (6) classifications; of which a minimum of one (1) submissions must be for an installation project.

Project Classification No. 1

EG, 20 kW or larger?
YES ☐ or NO ☐

Project Title

Select the letter(s) for the contract number from Block 3 for this project.
A ☐
B ☐
C ☐
Please indicate if this project is Design and/or Install
☐ Design and/or ☐ Install
START DATE
COMPLETION DATE
FACILITY TYPE

If yes, provide details of the effort below:

Project Classification No. 2

UPS, facility size 40 kVA or larger;
YES ☐ or NO ☐

Project Title

Select the letter(s) for the contract number from Block 3 for this project.
A ☐
B ☐
C ☐
Please indicate if this project is Design and/or Install
☐ Design and/or ☐ Install
START DATE
COMPLETION DATE
FACILITY TYPE

If yes, provide details of the effort below:

Project Classification No. 3

FST Systems, 250 gallon tank or larger with environmental monitoring.
YES ☐ or NO ☐

Project Title

Select the letter(s) for the contract number from Block 3 for this project.
A ☐
B ☐
C ☐
Please indicate if this project is Design and/or Install
☐ Design and/or ☐ Install
START DATE
COMPLETION DATE
FACILITY TYPE

If yes, provide details of the effort below:

Project Classification No. 4

Underground cabling (direct buried) for ELD of a minimum of 1,000 feet, to include splicing and terminations OR Direct burial of low voltage conduit systems, installation of handholes with 500 feet of low voltage circuits to include termination;

YES ☐ or NO ☐

Project Title

Select the letter(s) for the contract number from Block 3 for this project.
A ☐
B ☐
C ☐
Please indicate if this project is Design and/or Install
☐ Design and/or ☐ Install
START DATE
COMPLETION DATE
FACILITY TYPE

If yes, provide details of the effort below:

Project Classification No. 5

AES such as photovoltaic/solar, wind power, fuel cells and other emerging alternative energy technologies.

AES system typically range from 1KW to 50KW YES ☐ or NO ☐

Project Title

Select the letter(s) for the contract number from Block 3 for this project.
A ☐
B ☐
C ☐
Please indicate if this project is Design and/or Install
☐ Design and/or ☐ Install
START DATE
COMPLETION DATE
FACILITY TYPE

If yes, provide details of the effort below:

Project Classification No. 6

LPGBS -There are five main components of LPGBS work: (1) exterior lightning protection , (2) earth electrode system (EES), (3) sensitive electronic equipment grounding systems, (4) surge protection, and (5) fences and gates grounding. LPGBS Project submission must include three (3) of the five (5) main components.
YES ☐ or NO ☐

Project Title

Select the letter(s) for the contract number from Block 3 for this project.
A ☐
B ☐
C ☐
Please indicate if this project is Design and/or Install
☐ Design and/or ☐ Install
START DATE
COMPLETION DATE
FACILITY TYPE

If yes, provide details of the effort below:

File details come from the government source that posted it. Updated .