J and A for Brand Name-Sole Source - Johnson Controls_Redacted.pdf

PDF 114 KB Posted

Attached to
187 FW F35 Simulator & Base Supply New Construction Federal contract opportunity
Solicitation number
W50S6N-22-B-0001
Issued by
Department of the Army Alabama Army National Guard

About this file

This justification and approval document describes a sole source procurement for direct digital control systems from Johnson Controls for two construction projects at an Air National Guard base in Alabama. The projects include construction of a new 19,000 square foot F-35 Simulator Facility and a new 39,000 square foot Supply Facility, both of which require direct digital controls that are compatible with Johnson Controls' existing basewide system for standardization and interoperability purposes. The justification cites Federal Acquisition Regulation authority for a sole source procurement when only one responsible source can satisfy the agency's requirements.

The related federal contract opportunity is a solicitation for a firm fixed-price construction contract valued between $10-25 million to build the two new facilities. The pre-bid conference will be held on October 26, 2021 and bids are due by an unspecified date. The North American Industry Classification code is 236220 and the procurement is 100% set aside for small businesses with a size standard of $39.5 million. The soliciting agency is the Department of the Army Alabama Army National Guard.

View the file

Other files for this federal contract opportunity

Other files attached to 187 FW F35 Simulator & Base Supply New Construction, newest first.
File Type Posted
W50S6N-22-B-0001-0002.pdf PDF
W50S6N-22-B-0001-0001.pdf PDF
W50S6N-22-B-0001-0003.pdf PDF
ADDENDUM 003 - FAKZ999088 and FAKZ189019.pdf PDF
W50S6N-22-B-0002-0002.pdf PDF
ADDENDUM 2 FAKZ999088 and 189019 SIGNED.pdf PDF
RFI RESPONSES 001 FAKZ999088 and 189019 REVISED SIGNED.pdf PDF
W50S6N-22-B-0002-0001.pdf PDF
FAKZ999088 - FAKZ189019 Addendum Number 1.pdf PDF
Pre Bid Slides_SIMSUPPLY.pdf PDF
Pre Bid Attendance Roster.pdf PDF
Attachment 4_FAKZ189019 Specs VOL 1.pdf PDF
Attachment 6_FAKZ999088 SPECS VOL 1.pdf PDF
J and A for Brand Name-Sole Source - Advantor_Redacted.pdf PDF
Attachment 2_FAKZ999088 B3 Drawings.pdf PDF
Attachment 3_Consolidated General Specs.pdf PDF
J and A for Brand Name-Sole Source - Stanley Best Locks_Redacted.pdf PDF
Entry Auth List.pdf PDF
W50S6N-22-B-0001 Solicitation.pdf PDF
Attachment 1_FAKZ189019 B3 Drawings.pdf PDF
Attachment 5_FAKZ189019 Specs VOL 2.pdf PDF
J and A for Brand Name-Sole Source - Monaco_Redacted.pdf PDF
Justification and Approval for Brand Name-Sole Source - Pavers_Redacted.pdf PDF
Attachment 7_FAKZ999088 SPECS VOL 2.pdf PDF
J and A for Brand Name-Sole Source - Krieger_Redacted.pdf PDF
Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Justification and Approval for Other Than Full and Open Competition

Sole Source Items within a Construction Project AFARS 5153.303-5

USPFO Alabama

Type of Action: Contract Type: Funding Type:

Name and describe the required supplies/services

New Contract Firm Fixed Price MILCON

FAKZ189019 – F-35 Simulator Facility & FAKZ999088 - Replace Base Supply Complex

The scope of work with relation to the limited sources includes the construction of a new 19,000 square foot F-35 Simulator Facility as well as construction of a 39,000 sf Supply facility. The Simulator Facility includes a large Secure Access Program Facility (SAPF) with multiple Compartmentalized Areas (SAPCA) and the Supply facility includes a smaller SAPF footprint. The SAPF areas in each facility are required to be constructed to the Intelligence Community Directive No. 705 (ICD-705) including STC rated construction, access control systems, and intrusion detection systems. This construction requires tests/inspections conducted by the Air Force that have to be passed before the facility is authorized to use.

The Simulator facility and the Supply Building have associated Mechanical Systems including chilled/hot water HVAC systems with redundant air handlers and chillers for facility resilience. They also have Reverse Osmosis water treatment systems and dedicated humidifiers for precise humidity control. The Simulator Facility also includes multiple dedicated computer room air conditioners to support F-35 simulator systems. This system will include the installation of a direct digital control system for each facility. The associated Electrical Systems include new pad mounted transformer, electrical distribution system, surge protection and lightning protection systems. Fiber optic service is provided from Building 1109. Secure and non-secure telecommunications are the backbone systems for compliance with applicable ICD-705 requirements.

United States Code 3304(a)(1) as implemented in Federal Acquisition Regulation 6.302-1(a)(2)(ii)(B), Only one responsible source and no other supplies or services will satisfy agency requirements.

The 187th exclusively utilizes Johnson Controls for HVAC system's Direct Digital Controls. This is the only manufacturer that is utilized basewide for reasons of standardization and guaranteed interoperability.

Risk: If the 187th built a facility that does not utilize this system, the ability to control and monitor base utilities would be compromised. Utilizing other manufacturers would necessitate the purchase of additional centralized monitoring systems for the the F-35 Simulator Facility and the new Base Supply Facility as well as Civil Engineering B1801. According to ANGETL 15-01-04, 20.1 "All ANG facility and site projects should provide or expand on the base Energy Management Control System (EMCS). All ANG facility HVAC systems should use complete DDC systems."

I certify that the supporting data under my cognizance, which are included in the justification are accurate and complete to the best of my knowledge and belief.

Date:

A pre-solicitation notice is placed in beta.sam.gov in order to give contractors an early notification of this project. However, due to the proprietary nature of the Johnson Controls system no effort to compete these brand name requirements will be made.

None.

Direct Digital Control (DDC) systems are not designed to be compatible with different DDC manufactures. Utilizing other manufacturers would necessitate the purchase of additional centralized monitoring systems for the the F-35 Simulator Facility, the new Base Supply Facility and Civil Engineering B1801.

N/A

01-Apr-2021 Maj Adam Sanders

187 FW Base Civil Engineer

SANDERS.ADAM.WA

YNE.1110351549

Digitally signed by

SANDERS.ADAM.WAYNE.1110351549

Date: 2021.04.01 12:18:02 -05'00'

I certify that the supporting data under my cognizance, which are included in the justification are accurate and complete to the best of my knowledge and belief.

Date:

I certify that this justification is accurate and complete to the best of my knowledge and belief.

Date:

01-Apr-2021 Maj Adam Sanders

187 FW Base Civil Engineer

SANDERS.ADAM.WA

YNE.1110351549

Digitally signed by

SANDERS.ADAM.WAYNE.1110351549

Date: 2021.04.01 12:18:19 -05'00'

06-Jul-2021 William 'Craig' Kast

Contracting Officer

KAST.WILLIAM.CRAI

G.1110182933

Digitally signed by

KAST.WILLIAM.CRAIG.1110182933

Date: 2021.07.06 18:51:21 -05'00'

Based on the foregoing justification, I hereby approve the procurement of on an other than full and open competition basis pursuant to the authority of subject to availability of funds, and provided that the services and property herein described have otherwise been authorized for acquisition.

Johnson Controls System.

United States Code 3304(a)(1) FAR 6.302-1(a)(2)(ii)(B), Only one responsible source and no other supplies or services will satisfy agency

07-Jul-2021 William 'Craig' Kast

Contracting Officer

KAST.WILLIAM.CRAI

G.1110182933

Digitally signed by

KAST.WILLIAM.CRAIG.1110182933

Date: 2021.07.07 16:49:25 -05'00'

File details come from the government source that posted it. Updated .