This document is a drydock evaluation form and federal contract opportunity notice for the regular overhaul of the USNS ROBERT E. PEARY (T-AKE 5). The drydock evaluation form provides ship characteristics including length, draft, displacement and blocking requirements. It also outlines minimum services needed from shipyards including electrical power, sewage connections, fire main, auxiliary seawater, fresh water, compressed air, shore steam and high pressure water wash. The related federal contract opportunity is solicitation number N3220521R4125 from the Department of the Navy's Military Sealift Command for the regular overhaul of the USNS ROBERT E. PEARY (T-AKE 5) to replace the earlier sources sought notice. Interested vendors must meet the ship and drydock specifications and minimum services defined in the evaluation form to qualify for the overhaul work.
View the file
Other files for this federal contract opportunity
Show all 27
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N3220520R6501
N3220521R4125
MSC DRYDOCK EVALUATION FORM
| Ship name: |
| USNS ROBERT E. PEARY |
| Hull No: |
| T-AKE 5 |
PART A (to be completed by MSC)
PART B (to be completed by ALL shipyards)
Drydock Certification / Classification Info
Shipyard name
Drydock No.
Drydock Type Graving |_| Floating |_| Marine Railway |_|
Certified? Yes |_| No |_|
Certifying / Classifying Agency
Certificate No.
Date of expiration
| Ship Characteristics |
| English measure |
| Metric measure |
Provide date in English and Metric Units:
| Length, overall |
| 689 |
| ft - |
| 0 |
| In |
| 210.0 m |
Drydock Characteristics
| Breadth, molded |
| 105 |
| ft - |
| 7 |
| In |
| 32.2 m |
Length, overall ft-in m
| Draft, light load line |
| 23 |
| ft - |
| 4 |
| In |
| 7.2 m |
Breadth ft-in m
| Gross Tonnage (U. S.) |
| 43758 |
| Tons |
MT
| Displacement, Full Load |
| 41470 |
| LT |
44778 MT
Maximum drydock lift capability
LT
MT
Minimum Displacement/Draft
| Displacement |
| 24831 |
| LT |
25230 MT
| Draft – forward |
| 20 |
| ft - |
| 4 |
| In |
| 6.2 m |
Maximum entry draft rating:
LT
MT
| Draft – aft |
| 20 |
| ft - |
| 4 |
| In |
| 6.2 m |
Max stern trim for graving dock
| ft - |
| 0 |
| In |
| m |
Water depths around dock ft-in m area and approaches, tidal conditions, Anticipated Arrival Draft and any unusual conditions for entering/
| Draft - forward |
| 24 |
| ft - |
| 0 |
| In |
| 7.3 m |
leaving the drydock.
| Draft - aft |
| 26 |
| ft - |
| 0 |
| In |
| 8.1 m |
Depth Over Floor ft-in m
Positioning Clearances
Depth Over Blocks ft-in m
| Bottom: keel to drydock floor |
| 5 |
| ft - |
| 0 |
| In |
| 1.5 m |
Depth Over Sill ft-in m
| Side: hull to drydock wall |
| 5 |
| ft - |
| 0 |
| In |
| 1.5 m |
Depth Over KEEL ft-in m
Loading Pressures
| Max block loading |
| 17.65 |
| Tons Per square ft. |
| 193.0 per sq mtr |
Note: All blocks to be positioned under longitudinal strength members and transverse bulkheads.
MSC DRYDOCK EVALUATION FORM (cont’d)
PART A (to be completed by MSC)
PART B (to be completed by ALL shipyards)
Max Block Loading Capability
Blocking Requirements
Block Capability
LT/ft2
LT/m2
| Construction |
| Hard Wood |
Keel & Side Block Information
| Cap material |
| Soft Wood |
Construction
| Cap thickness (min) |
| 2 |
Cap Material
| Side blocks (e.g., shaped, wedged, etc.) |
| Shaped |
Cap Thickness in cm
Block Age
Hardwood: White Oak, California Laurel, Oregon Myrtle, Iron bark, Height ft-in m
Blue Gum, American Rock Elm or Preserved Red Oak.
Width ft-in m
Softwood: Douglas Fir, Tamarack, Long Leaf Pine or Hemlock
Length ft-in m
Minimum Required Services
Minimum Available Services
Electrical power
Electrical power
| AC volts | |
| 505 | |
| VAC |
AC volts
| number of phases | |
| 3 |
number of phases
VAC
| amperage (total) | |
| 5600 | |
| Amps |
amperage (total)
| frequency | |
| 60 | |
| Hz |
frequency amps
| number of lines | |
| 20 |
number of lines
Hz
Ground connections
Ground connections
| number | |
| 2 |
number
| cable size, each | |
| 500,000 | |
| cir mils |
cable size, each cir mils
Sewage connections
Sewage connections
| number | |
| 1 |
number
| pipe size | |
| 2 1/2 | |
| inch ips |
pipe size
| capacity | |
| 1,000 | |
| gals per day | |
| 3,785 liters per day |
capacity inch ips cm gal/day ltr/day
Fire Main
Fire Main
| number of connections | |
| 2 |
number of connections
| connection size | |
| 2 1/2 | |
| inch ips |
connection size
| pressure | |
| 125 | |
| Psig | |
| 8.8 | kg per sq cm |
pressure inch ips cm
| capacity | |
| 1,000 | |
| gals per min | |
| 3,785 liters per min |
capacity psig kg/m2 gpm ltr/min
Aux Seawater
Aux Seawater
| pressure | |
| 100 | |
| Psig | |
| 7.0 | kg per sq cm |
pressure
| capacity | |
| 600 | |
| gals per min | |
| 2,271 liters per min |
capacity psig kg/m2 gpm ltr/min
Fresh Water
Fresh Water
| pressure | |
| 60 | |
| Psig | |
| 4.2 | kg per sq cm |
pressure
| capacity | |
| 100 | |
| gals per min | |
| 378 | liters per min |
capacity psig kg/m2 gpm ltr/min
MSC DRYDOCK EVALUATION FORM (cont’d)
Compressed Air
Compressed Air
| pressure | |
| 125 | |
| Psig | |
| 8.8 | kg per sq cm |
pressure
| capacity | |
| 200 | |
| cu ft per min | |
| 5,664 liters per min |
capacity psig kg/m2 cfm ltr/min
Shore Steam
Shore Steam
| pressure | |
| 100 | |
| psig | |
| 7.0 kg per sq cm |
pressure
| capacity | |
| 6,000 | |
| lbs per hour | |
| 2,722 kg per hour |
capacity psig kg/m2 lb/hr kg/hr
| High Pressure Water Wash pressure | |
| 6,000 | |
| psig | |
| 422 | kg per sq cm |
High Pressure Water Wash pressure psig kg per sq cm
Safety Response Plans Required
Safety Response Plans Available (circle correct answer)
| Firefighting | |
| Yes | X |
| No | |_| |
Firefighting
| Flooding (accidental) | |
| Yes | X |
| No | |_| |
| Flooding (accidental) |
| Yes |
| No |
| Earthquake | |
| Yes | |_| |
| No | X |
| Earthquake |
| Yes |
| No |
| Typhoon | |
| Yes | |_| |
| No | X |
| Typhoon |
| Yes |
| No |
PART C (to be completed by Shipyard if drydock is not certified by IACS or under MIL STD 1625C)
Dockmaster info
Contractor name
Dockmaster name
Certifying Agency
Certificate No.
Years experience
Drydock Insurance Info
| Is Drydock insured? | |
| Yes |_| | No |_| |
Insurer
Policy No.
Amount Insured
Date of expiration