This document provides details for a federal construction solicitation opportunity. The General Services Administration Public Buildings Service is seeking construction services for retaining wall repairs at the Western North Carolina Regional Center through an indefinite delivery/indefinite quantity contract vehicle. Offerors should respond to solicitation number NCRFY24SolicitationConstructionIDIQ by the unspecified due date to be considered for task orders to design and build the retaining wall over the next several years. Pricing terms and set-asides were not indicated in this summary document.
View the file
Other files
Show 40 more
Latest 50 of 52 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SENSITIVE BUT UNCLASSIFIED
(SBU) PROPERTY OF THE
UNITED STATES GOVERNMENT
COPYING, DISSEMINATION, OR
DISTRIBUTION OF THIS
DOCUMENT TO UNAUTHORIZED
RECIPIENTS IS PROHIBITED
Do not remove this notice.
Properly destroy or return documents when no longer needed.
FINAL SUBMISSION
PROJECT TEAM
SECURITY NOTICE
DRAWING INDEX
RETAINING WALL INVESTIGATION AND SOLUTION
VICINITY MAP
SCOPE OF WORK
U.S. GENERAL SERVICES ADMINISTRATION (GSA)
ARCHITECT
GEOTECHNICAL ENGINEER
CIVIL ENGINEER
STRUCTURAL ENGINEER
CONSTRUCTION COST ESTIMATOR
LOCATION MAP
WASHINGTON NATIONAL RECORDS
4205 SUITLAND ROAD
SUITLAND, MARYLAND 20746
HAZARDOUS MATERIALS
APPLICABLE CODES, GOVERNING
STANDARDS AND CRITERIA
DOCUMENTS
Ÿ
Ÿ
Ÿ Ÿ Ÿ
Ÿ Ÿ Ÿ
Ÿ Ÿ
Ÿ
FINAL SUBMISSION
FINAL SUBMISSION
Ÿ
Ÿ Ÿ Ÿ
Ÿ
Ÿ
Ÿ Ÿ Ÿ
Ÿ
Ÿ
Ÿ Ÿ Ÿ
Ÿ Ÿ Ÿ
Ÿ Ÿ
Ÿ
Ÿ
Ÿ Ÿ Ÿ
Ÿ
Ÿ
Ÿ Ÿ Ÿ
Ÿ
ŸŸ
I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional architect under the laws of the State of Maryland, License No. 9635, Expiration Date: 08/16/2023.
SITE
LOCATION
U:
\A cc ou nt s\M
TF
AX
\M
TF
AX
- G
SA
D C
Na tio na l R ec or ds R et ain ing W all \D
ES
IG
N\ _S
HE
ET
S\ M
TF
AX
1-
CS
.d wg
PL
OT
TE
D:
2/
/2
8:
A M, B
Y:
Na de jda
B ur diu ja
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
PR
OJ
EC
T
ST
AT
US
PENNONI ASSOCIATES INC.
1602 Village Market Blvd SE, Suite 330
Leesburg, VA 20175 T 703.777.3616 F 703.777.3725
RETAINING WALL REPLACEMENT
WASHINGTON NATIONAL RECORDS CENTER (WNRC) SUITLAND, MARYLAND
FEBRUARY 15, 2022
GSA PROJECT CONTROL # RMD84124
LOCATION MAP
SCALE: 1" = 100' INDEX OF CIVIL ENGINEERING DRAWING
1 PRE-FINAL SUBMISSION 10-15-2021
2 MDE SUBMISSION 12-3-2021
I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No. 19185, Expiration Date: 07/01/23.
MDE No. 22-SF-0088
3 PRE - FINAL DESIGN 1-11-2022
4 FINAL DESIGN 02-11-2022
5 FINAL DESIGN & MDE 2ND SUBMISSION 02-15-2022
U:
\A cc ou nt s\M
TF
AX
\M
TF
AX
- G
SA
D C
Na tio na l R ec or ds R et ain ing W all \D
ES
IG
N\ _S
HE
ET
S\ M
TF
AX
1-
CS
TE
D:
2/
/2
9:
A M, B
Y:
Na de jda
B ur diu ja
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
PR
OJ
EC
T
ST
AT
US
PENNONI ASSOCIATES INC.
1602 Village Market Blvd SE, Suite 330
Leesburg, VA 20175 T 703.777.3616 F 703.777.3725
GENERAL CIVIL ENGINEERING AND SITE PLAN NOTES AND CONDITIONS
GENERAL CONDITIONS
1. BENCHMARK INFORMATION:
BENCHMARK 1 TRAV1GPS IRON REBAR WITH CAP. ELEV=262.98' BENCHMARK 2 TRAV2GPS IRON REBAR WITH CAP. ELEV=253.75'
BENCHMARK 3 TRAV3GPS IRON REBAR WITH CAP. ELEV=286.31'
PENNONI PROJECT CONTROL AND BENCHMARKS ARE LOCATED ON DRAWING CS0201 FOR THIS PROJECT.
A.THE BENCHMARK DATA PROVIDED IS BASED UPON INFORMATION OF RECORD AND IS PROVIDED TO ACCOMMODATE DESIGN REVIEWS. BECAUSE BENCHMARKS ARE SUBJECT TO CHANGE AND/OR DISTURBANCE OVER TIME, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THIS INFORMATION, AND TO NOTIFY PENNONI (703-449-6700) AND THE CONTRACTING
OFFICER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION.
B.IF PENNONI IS NOT PROVIDING STAKE OUT SERVICES FOR THIS PROJECT, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO ESTABLISH AND CONFIRM ALL VERTICAL AND HORIZONTAL CONTROLS TO BE USED FOR THIS PROJECT. FURTHER, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COMPUTE THE LAYOUT OF ALL PROPOSED SITE CONSTRUCTION (INCLUDING BUILDINGS, UTILITIES, PAVEMENTS, AND APPURTENANCES) CONSISTENT AND IN ACCORDANCE WITH THESE PLANS, IN ADVANCE OF COMMENCING THE WORK ASSOCIATED WITH THESE PLANS. COMPUTED LAYOUTS SHALL BE SUBMITTED TO AND APPROVED BY THE CONTRACTING OFFICER IN WRITING PRIOR TO CONSTRUCTION.
2. UNLESS OTHERWISE NOTED ON THIS SURVEY, LOCATIONS AND CONNECTIONS OF STORM AND SANITARY SEWER FACILITIES SHOWN HEREON ARE BASED ON OBSERVED FIELD EVIDENCE.
AS-BUILT INFORMATION OF ACCESSIBLE STRUCTURES HAVE BEEN PROVIDED, IF OBTAINABLE.
3. WHILE REASONABLE CARE HAS BEEN TAKEN IN IDENTIFYING UNDERGROUND UTILITIES AND CONNECTIONS, THEY ARE APPROXIMATE AND BASED ON OBSERVED ABOVE GROUND FACILITIES AND/OR SUBSURFACE UTILITY PAINT MARKINGS ONLY. THEREFORE, ACCURACY OF CONNECTIONS CANNOT BE GUARANTEED. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE EXACT LOCATION OF ALL UTILITIES PRIOR TO CONSTRUCTION AND FOR ANY DAMAGES THAT MAY OCCUR DUE TO THEIR FAILURE TO LOCATE AND PROTECT THESE UNDERGROUND FACILITIES.
4. CONTRACTOR TO VERIFY FIELD CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND NOTIFY THE CONTRACTING OFFICER AND THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND APPROVED PLAN. SHOULD CONFLICTS BE DISCOVERED WITHIN THE INFORMATION PRESENTED IN THIS PLAN, THE CONTRACTOR SHALL CONTACT THE
CONTRACTING OFFICER TO DISCUSS/RESOLVE PRIOR TO ANY FURTHER CONSTRUCTION.
5. CONSTRUCTION SHALL BE EXECUTED AND PHASED IN SUCH A MANNER AS TO MINIMIZE ANY DISRUPTION OF THE EXISTING VEHICULAR AND/OR PEDESTRIAN TRAFFIC ACCESS AND CIRCULATION IN THE VICINITY OF THE PROPOSED CONSTRUCTION. THE CONTRACTOR SHALL REQUEST ANY SUCH CLOSURE OR DISRUPTION IN WRITING AT LEAST 30 DAYS PRIOR TO REQUESTED CLOSURE OR DISRUPTION. NO CLOSURE WILL BE ALLOWED WITHOUT WRITTEN PERMISSION FROM THE CONTRACTING OFFICER.
6. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE EXACT LOCATION OF ALL UTILITIES PRIOR TO CONSTRUCTION AND WILL BE RESPONSIBLE FOR ANY DAMAGES THAT MAY OCCUR DUE TO THEIR FAILURE TO LOCATE AND PROTECT ANY UNDERGROUND FACILITIES. OBTAIN DIGGING PERMITS PRIOR TO START OF EXCAVATION BY CONTACTING THE CONTRACTING OFFICE 15 CALENDAR DAYS IN ADVANCE. SCAN THE CONSTRUCTION SITE WITH ELECTROMAGNETIC OR SONIC EQUIPMENT (I.E. EM OR GPR), AND MARK THE SURFACE OF THE GROUND WHERE EXISTING UNDERGROUND UTILITIES ARE DISCOVERED. VERIFY THE ELEVATIONS, MATERIALS AND SIZES OF EXISTING PIPING, UTILITIES, INCLUDING ANY TYPE OF UNDERGROUND OBSTRUCTION NOT INDICATED OR SPECIFIED TO BE REMOVED, BUT INDICATED OR DISCOVERED DURING SCANNING IN THE LOCATIONS TO BE TRAVERSED BY PIPING AND OTHER WORK TO BE INSTALLED. VERIFY ELEVATIONS BEFORE INSTALLING NEW WORK CLOSER THAN NEAREST MANHOLE OR OTHER STRUCTURE AT WHICH AN ADJUSTMENT IN GRADE CAN BE MADE. USE OF SCANNING EQUIPMENT MUST BE CERTIFIED BY NAVFAC SAFETY OFFICE FOR USE ON THE BASE. CONTACT THE CONTRACTING OFFICER FOR INSTRUCTIONS ON OBTAINING THIS CERTIFICATION.
7. DENOTES TEST HOLE REQUIRED TO DETERMINE EXACT LOCATION, MATERIAL, SIZE, VERTICAL AND HORIZONTAL ELEVATION OF EXISTING UTILITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DIGGING OF TEST HOLES PRIOR TO BEGINNING OF ANY CONSTRUCTION ON THE PROJECT. ALL CONFLICTS DISCOVERED AS A RESULT OF TEST HOLE FINDINGS SHALL BE REPORTED TO THE CONTRACTING OFFICER IMMEDIATELY. DO NOT START WORK UNTIL THE CONFLICTS ARE RESOLVED.
8. ALL CONSTRUCTION SHALL CONFORM TO THE UNIFIED FEDERAL CRITERIA (UFC) AND THE MARYLAND STATE HIGHWAY ADMINISTRATION (MSHA) STANDARDS AND SPECIFICATIONS. IN CASE OF ANY CONFLICT BETWEEN THESE REQUIREMENTS, THE MOST STRINGENT STANDARDS SHALL TAKE PRECEDENCE.
10. ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING STANDARDS AND SPECIFICATIONS:
A. MARYLAND STATE HIGHWAY ADMINISTRATION (MSHA) STANDARDS AND SPECIFICATIONS
B. MDE MARYLAND STORMWATER MANAGEMENT GUIDELINES FOR STATE AND FEDERAL PROJECTS.
C. MDE MARYLAND STORMWATER DESIGN MANUAL
D. AMERICANS WITH DISABILITIES ACT (ADA)-WWW.ADA.GOV ALL CURRENT REQUIREMENTS AND REGULATIONS FOR ACCESSIBLE DESIGN.
E. ADA-ABA REGULATION-WWW.ACCESS-BOARD.GOV/ADA-ABA/DOD-MEMORANDUM.HTM INTERNATIONAL BUILDING CODE (IBC).
F. 2011 MARYLAND STANDARDS AND SPECIFICATIONS FOR SOIL EROSION AND SEDIMENT CONTROL
G. "UNIFIED FACILITIES CRITERIA (UFC) - UFC 3-201-01 CIVIL ENGINEERING
11. TYPICAL SECTIONS ARE INTENDED TO SHOW GENERAL FEATURES OF THE PROPOSED CONSTRUCTION. FOR EXACT DETAILS AT A GIVEN LOCATION, SEE PLANS.
12. THIS PROJECT SHALL BE APPROVED BY THE MARYLAND DEPARTMENT OF THE ENVIRONMENT, WATER SCIENCE ADMINISTRATION PRIOR TO START OF CONSTRUCTION.
13. THE CONSTRUCTION CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
REQUIRED PERMITTING FEES.
14. CONTRACTOR SHALL REMOVE LITTER AND CONSTRUCTION DEBRIS FROM THE SITE EACH DAY. LITTER, CONSTRUCTION DEBRIS, AND CONSTRUCTION CHEMICALS EXPOSED TO STORM WATER SHALL BE PREVENTED FROM BECOMING A POLLUTANT SOURCE FOR STORM WATER DISCHARGES AND SHALL NOT BE ALLOWED TO CLOG INLETS, NOR POLLUTE DISCHARGE CHANNELS.
15. NO SOLID MATERIALS, INCLUDING BUILDING MATERIALS, GARBAGE AND DEBRIS SHALL BE DISCHARGED TO SURFACE WATERS OF THE STATE, EXCEPT AS AUTHORIZED BY A CWA SECTION 404
PERMIT.
16. ALL EXISTING SURFACED STREETS AND SIDEWALKS THAT ARE OUTSIDE THE LIMITS OF DISTURBANCE SHALL BE MAINTAINED IN A CLEAN CONDITION, FREE OF DUST, MUD OR SNOWAT ALL
TIMES.
17. THE APPROVAL OF THIS PLAN DOES NOT CONSTITUTE THE APPROVAL OF FUTURE WORK OR WORK BY OTHERS.
18. THE APPROVAL OF THIS PLAN SHALL IN NO WAY RELIEVE THE OWNER/DEVELOPER OR HIS AGENT OF ANY LEGAL RESPONSIBILITIES WHICH MAY BE REQUIRED BY THE CODE OF MARYLAND OR
APPLICABLE ORDINANCES OR REQUIREMENTS.
19. NO GRAVE, OBJECT, STRUCTURE MARKING A PLACE OF BURIAL, OR OTHER ARCHEOLOGICAL SITE IS KNOWN TO EXIST ON THIS SITE.
GRADING AND EARTHWORK
20. ALL FINISHED GRADING, SEEDING, SODDING, OR PAVING SHALL BE DONE IN SUCH A MANNER AS TO PRECLUDE THE PONDING OF WATER ON THE SITE, PARTICULARLY ADJACENT TO BUILDINGS
AND STORM INLETS.
21. WHEN NECESSARY, AND IN KEEPING WITH THE DESIGN INTENT OF THE PLAN, MINOR ADJUSTMENTS TO GRADES AND ELEVATIONS, SHALL BE MADE IN THE FIELD WITH THE APPROVAL OF THE
OWNER/ENGINEER AND THE SITE INSPECTOR.
22. THE CONTROLLED FILL DENSITY SHALL BE CERTIFIED BY A REGISTERED PROFESSIONAL GEOTECHNICAL ENGINEER.
23. ALL BASE, SUBBASE AND SUBGRADE MATERIAL SHALL BE COMPACTED AT OPTIMUM CONTENT, WITHIN A TOLERANCE OF ± 2% OF OPTIMUM.
24. A GEOTECHNICAL REPORT HAS BEEN PREPARED BY PENNONI ASSOCIATES INC. (PENNONI) DATED JUNE 4, 2021, AND REVISED JUNE 21, 2021. THE CONTRACTOR SHALL OBTAIN AND BE FAMILIAR WITH THIS GEOTECHNICAL REPORT, AND CONFIRM THAT ALL GEOTECHNICAL-RELATED CONSTRUCTION COMPLIES WITH THE FINDINGS AND RECOMMENDATIONS OF THIS REPORT. IF THERE IS ANY DISCREPANCY DISCOVERED BETWEEN THE GEOTECHNICAL REPORT AND THESE DRAWINGS, SUCH DISCREPANCY SHALL BE REPORTED TO THE OWNER AND THE ENGINEER IMMEDIATELY, AND THE ASSOCIATED CONSTRUCTION SHALL NOT PROCEED UNTIL WRITTEN RESOLUTION OF THE DISCREPANCY IS PROVIDED BY THE OWNER AND THE ENGINEER.
GENERAL DEMOLITION NOTES
25. THE CONTRACTOR SHALL COORDINATE ALL REMOVAL EFFORTS WITH THE OWNER.
26. ANY HARDWOOD TREE WITH A DBH GREATER THAN 6” SHALL BE LIMBED, CUT IN 8' SECTIONS, AND STACKED AT A SITE TO BE DETERMINED BY OWNER AND ENGINEER. COORDINATION WITH OWNER AND
ENGINEER WILL BE REQUIRED PRIOR TO TREE REMOVAL.
27. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO EXISTING ROADS, APPURTENANCES AND UTILITIES WHICH MAY OCCUR AS A RESULT OF THEIR CONSTRUCTION WITHIN OR CONTIGUOUS TO THE PROJECT SITE. ANY DAMAGE TO EXISTING ROADWAYS OR OTHER EXISTING FACILITIES SHALL BE REPAIRED TO BETTER THEN EXISTING CONDITIONS BY THE CONTRACTOR
AT NO ADDITIONAL COST TO THE GOVERNMENT.
28. NO EARTH DISTURBANCE SHALL OCCUR UNTIL THE PLAN HAS BEEN APPROVED BY MDE/WMA AND APPROVAL TO PROCEED GIVEN BY THE CONTRACTING OFFICER. THIS PROJECT REQUIRES APPROVED SEDIMENT AND EROSION CONTROL PLANS. THE CONTRACTOR SHALL SIGN THE ORIGINAL COPY OF THE APPROVED SEDIMENT AND EROSION CONTROL PLANS AS THE RESPONSIBLE PERSONNEL PRIOR TO BEGINNING ANY SOIL DISTURBING WORK. NO CONSTRUCTION SHALL BEGIN UNTIL THE PLAN HAS BEEN APPROVED BY
MDE/WMA AND THE CONTRACTING OFFICER HAS GIVEN APPROVAL TO PROCEED.
29. EXCAVATION SUPPORT SYSTEMS SHALL CONFORM TO THE PROVISIONS OF OSHA CONSTRUCTION STANDARD 29 CFR PART 1926 SUBPART P AND COE SAFETY AND HEALTH DEPARTMENT
REQUIREMENT MANUAL EM 385-1-1, JANUARY 2018.
30. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ANY NECESSARY EXCAVATION PERMITS FROM THE OWNER, INCLUDING ALL REQUIRED FEES AND COORDINATION.
31. NO SEDIMENTATION SHALL BE ALLOWED TO EXIT PERMITTED LIMITS OF DISTURBANCE. THE CONTRACTOR SHALL REPAIR ANY DAMAGE TO THE EXISTING STORMWATER FACILITIES CAUSED IN ANY MANNER BY ACTIVITIES RELATED TO THE CONSTRUCTION OF THIS PROJECT, INCLUDING BUT NOT LIMITED TO SEDIMENTATION FROM CONSTRUCTION RUNOFF.
EXTERIOR IMPROVEMENTS (PAVEMENTS, LANDSCAPE, AND FENCING, ETC.)
32. THE PAVEMENT SECTION SHOWN ON THESE DRAWINGS IS BASED ON A PRELIMINARY CBR VALUE OF 5. THE CONTRACTOR SHALL PERFORM SUBGRADE TESTING AT THE TIME OF FINAL DESIGN AND CONSTRUCTION AND THE PAVEMENT DESIGNS/SECTION ADJUSTED, AS NECESSARY, TO REFLECT ACTUAL CBR VALUES.
33. AT ALL CONNECTIONS TO EXISTING CURB AND GUTTER, THE CONTRACTOR SHALL TRANSITION NEW CURB AND GUTTER TO MEET AND MATCH EXISTING CURB AND GUTTER. SUCH TRANSITIONS SHALL BE CONSTRUCTED TO ENSURE POSITIVE DRAINAGE AND SHALL BE AT CURB RETURNS WHERE POSSIBLE.
34. ALL CONCRETE SIDEWALKS SHALL BE 4" THICK UNLESS OTHERWISE NOTED IN THE PLAN. SIDEWALK SCORE JOINT LOCATIONS SHALL BE AT A MAXIMUM OF 6' O.C. SIDEWALK EXPANSION JOINTS SHALL BE A MAXIMUM OF 30' O.C. AND AT CHANGE IN MATERIAL AND AT PERIMETER OF STRUCTURES, UNLESS OTHERWISE SHOWN ON THE PLANS.
35. WALKWAYS SHALL BE CONSTRUCTED WITH A CROSS SLOPE OF 2% UNLESS OTHERWISE NOTED IN THE PLAN OR APPROVED BY THE ENGINEER, INCLUDING WALKWAYS CROSSING DRIVEWAY APRONS. CONSTRUCT WALKWAYS TO A MINIMUM LONGITUDINAL SLOPE OF 1%, EXCEPT WHERE WITHIN SAGS AND CRESTS, WITH ADEQUATE DRAINAGE. UNLESS OTHERWISE SHOWN ON THE PLAN, CONSTRUCT WALKWAYS TO A MAXIMUM LONGITUDINAL SLOPE OF 5%, OR TO MATCH ADJACENT ROADWAY GRADES, WHICHEVER IS GREATER.
36. UNLESS MORE STRINGENT COMPACTION REQUIREMENTS ARE NOTED ON THIS PLAN, THE SUBGRADE FOR ALL WALKWAYS SHALL BE COMPACTED TO A MINIMUM OF 95% OF THEORETICAL MAXIMUM DENSITY AT OPTIMUM MOISTURE CONTENT WITHIN THE TOLERANCE SPECIFIED IN THE CURRENT EDITION OF MSHA SPECIFICATIONS.
37. CONTROLLED FILLS SHALL BE COMPACTED TO 95% OF MAXIMUM DENSITY AS DETERMINED BY METHOD 'A' PER STANDARD PROCTOR AASHTO T-99, ASTM D698 AS APPLICABLE. DENSITY SHALL BE CERTIFIED BY A REGISTERED PROFESSIONAL AND RESULTS SUBMITTED TO THE APPROPRIATE JURISDICTION PRIOR TO PAVEMENT CONSTRUCTION.
38. ALL PAVEMENT STRIPING SHALL MEET THE CURRENT STANDARDS AND REQUIREMENTS OF THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND SHALL BE THERMOPLASTIC
UNLESS OTHER SPECIFIED IN THIS PLAN.
39. A BITUMINOUS TACK COAT SHALL BE USED BETWEEN LIFTS OF BITUMINOUS PAVEMENT, PER MARYLAND STANDARDS AND SPECIFICATIONS.
40. ANY NEW PAVEMENT OPENED TO TRAFFIC SHALL RECEIVE A TACK COAT PRIOR TO PLACEMENT OF ANY OVERLYING ASPHALT COURSE.
41. AT LOCATIONS WHERE THE FINAL ASPHALT SURFACE COURSE IS TO BE FEATHERED INTO THE EXISTING ASPHALT SURFACE, THE EXISTING SURFACE COURSE SHALL BE SCABBLED TO A MINIMUM DEPTH OF 1.25 INCHES AND A TACK COAT SHALL BE APPLIED PRIOR TO FINAL PAVING TO ENSURE A SMOOTH WELL-BONDED JOINT. ADDITIONALLY, ALL CONNECTION TO EXISTING PAVEMENTS SHALL COMPLY WITH TYPICAL PAVEMENT JOINT DETAIL ON DRAWING CS3001.
GENERAL UTILITY NOTES:
42. ALL UTILITIES ARE TO BE RELOCATED AT THE CONTRACTOR'S EXPENSE. NO UTILITY INTERRUPTIONS SHALL BE ALLOWED UNLESS SPECIFICALLY PERMITTED BY THE CONTRACTING OFFICER.
ALL PERMITTED UTILITY INTERRUPTIONS SHALL BE REQUESTED FROM THE CONTRACTING OFFICER 30 CALENDAR DAYS IN ADVANCE AND SHALL BE SCHEDULED AND PERFORMED AFTER
WORKING HOURS.
43. PROVIDE 1' MINIMUM CLEARANCE BETWEEN UTILITY CROSSINGS.
44. PROVIDE A MINIMUM OF 4 FEET OF COVER OVER ALL WATER LINES.
45. DO NOT DISTURB, REMOVE, OR RELOCATE ANY ELECTRICAL LINES.
48. COORDINATE WITH OWNER AND ENGINEER TO RE-ROUTE OR RELOCATE ANY EXISTING UTILITY THAT CONFLICTS WITH CONSTRUCTION.
49. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER WASHINGTON SUBURBAN SANITARY COMMISSION (WSSC) STANDARDS AND SPECIFICATIONS. CONTRACTOR SHALL COORDINATE WITH WSSC FOR ALL WATER AND SEWER
CONSTRUCTION.
50. EXISTING MANHOLE FRAMES, COVERS AND VALVE BOXES SHALL BE ADJUSTED AND/OR RE- CONSTRUCTED, AS NECESSARY, TO MATCH FINISHED GRADES.
FILTER FABRIC - TO BE PROVIDED PER C1 - WALL SECTION, AND BETWEEN STRUCTURAL FILL AND UL-FGA, AS FOLLOWS:
a. FABRIC SHALL BE A NONWOVEN FABRIC CONSISTING OF LONG CHAIN POLYMERIC FILAMENTS OR YARNS OF POLYPROPYLENE, POLYESTER, POLYAMIDE, OR POLYVINYLIDENE-CHLORIDE FORMED INTO A
STABLE NETWORK.
b. FABRIC SHALL BE INERT TO CHEMICALS COMMONLY ENCOUNTERED IN SOIL AND TO HYDROCARBONS.
c. FABRIC SHALL BE RESISTANT TO MILDEW, ROT, AND INSECT AND RODENT ATTACKS.
d. FABRIC SHALL CONTAIN ULTRAVIOLET RAY INHIBITORS AND STABILIZERS AND BE SUITABLE FOR USE AT TEMPERATURES OF 0°F TO 120°F.
e. FABRIC SECURING PINS SHALL BE 3/16-INCH DIAMETER STEEL, POINTED AT ONE END, AND FABRICATED AT THE OTHER END WITH A HEAD TO RETAIN A STEEL WASHER HAVING AN OUTSIDE DIAMETER OF NOT
LESS THAN 1 1/2 INCHES. PIN LENGTH SHALL BE AT LEAST 18 INCHES.
51. THIS SITE IS COVERED BY AN MS-4 PERMIT AND WILL BE SUBJECT TO EXTRA SCRUTINY BY MDE.
1 PRE-FINAL SUBMISSION 10-15-2021
2 MDE SUBMISSION 12-3-2021
I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No. 19185, Expiration Date: 07/01/23.
SOIL EROSION & SEDIMENT CONTROL
SHALL BE STRICTLY ENFORCED.
NO DISTURBED AREAS SHALL BE LEFT UNSTABILIZED OVERNIGHT UNLESS THE
RUNOFF IS DIRECTED TO AN MDE APPROVED SEDIMENT CONTROL DEVICE.
MDE No. 22-SF-0088
3 PRE - FINAL DESIGN 1-11-2022
cc ou nt s\M
TF
AX
\M
TF
AX
- G
SA
D C
Na tio na l R ec or ds R et ain ing W all \D
ES
IG
N\ _S
HE
ET
S\ M
TF
AX
1-
CS
TE
D:
2/
/2
9:
A M, B
Y:
Na de jda
B ur diu ja
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
PR
OJ
EC
T
ST
AT
US
PENNONI ASSOCIATES INC.
1602 Village Market Blvd SE, Suite 330
Leesburg, VA 20175 T 703.777.3616 F 703.777.3725
ABBREVIATIONS FOR SITE / CIVIL DRAWINGS
A AREA
AC ACRE
ABP ANGLE OF BULK PLANE
ATFP ANTITERRORISM FORCE PROTECTION
BC BACK OF CURB
BEAP BASE EXTERIOR ARCHITECTURAL PLAN
BM BENCH MARK
BMP BEST MANAGEMENT PRACTICES
BOL BOLLARD
BW BOTTOM OF WALL
C/C FACTOR RUNOFF COEFFICIENT
CD CHECK DAM
C&G CURB AND GUTTER
CFS CUBIC FEET PER SECOND
CIP CURB INLET PROTECTION
CL CENTERLINE
CLR CLEAR/CLEARANCE
CMF CONCRETE MONUMENT FOUND
CO CLEAN OUT
COMM. COMMUNICATION, TELECOMMUNICATION
CONC. CONCRETE
CULV. CULVERT
CVI COMMERCIAL VEHICLE INSPECTION
CVR COVER
D.B. DEED BOOK
DIA. DIAMETER
D.I.P. DUCTILE IRON PIPE
DT DECIDUOUS TREE
DWG DRAWING
EG EDGE OF GRAVEL
ELEC. ELECTRICAL
ELEV. ELEVATION
EP EDGE OF PAVEMENT
E & S EROSION & SEDIMENTATION CONTROL
ESMT. EASEMENT
EX./EXIST. EXISTING
FDN FOUNDATION
FFE FINISHED FLOOR ELEVATION
FH FIRE HYDRANT
FO FIBER OPTIC LINE
G GAS
GALV. GALVANIZED
GB GUTTER BUDDY
HC HEADER CURB
HCR HANDICAP RAMP
HP HIGH POINT
HWY. HIGHWAY
INC INCREMENTAL
INV. INVERT
IP INLET PROTECTION
IPF IRON PIPE FOUND
IPS IRON PIPE SET
JB JUNCTION BOX
LAT LATERAL
LB/LBS POUNDS
LONG LONGITUDE
LP LIGHT POLE, LOW POINT
MAX. MAXIMUM
MIN. MINIMUM
MH MANHOLE
MM MEET AND MATCH
MUTCD MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES
NAVFAC NAVAL FACILITIES ENGINEERING COMMAND
NCPC NATIONAL CAPITAL PLANNING COMMISSION
NMMC NATIONAL MILITARY MEDICAL CENTER
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OHE OVERHEAD ELECTRICAL
OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
PP POWER POLE/PRESSURE PIPE
PERM. PERMANENT
PG. PAGE
PKNF PK NAIL FOUND
PRC POINT OF REVERSE CURVATURE
PVC POLYVINYL CHLORIDE
R/W, R.O.W. RIGHT OF WAY
RCP REINFORCED CONCRETE PIPE
REM. REMOVE
RR REMOVE AND RELOCATE, RAILROAD
RTE. ROUTE
S/W SIDEWALK
SAF SAFETY FENCE
SAN. SEW. SANITARY SEWER
SEC. SECTION
SF SQUARE FEET/SILT FENCE
SS SILTSOX
SSF SUPER SILT FENCE
STD. STANDARD
STM.DRN.STM.SEW. STORM DRAIN, STORM SEWER
SWM STORMWATER MANAGEMENT
TBR TO BE REMOVED
TC TOP OF CURB
TELE TELECOMMUNICATIONS EQUIPMENT
TP TELEPHONE POLE/TREE PROTECTION
TRANS TRANSFORMER, TRANSITION
TW TOP OF WALL
TYP. TYPICAL
UFC UNIFIED FACILITIES CRITERIA
UGE UNDERGROUND ELECTRICAL
UGT UNDERGROUND TELECOMMUNICATIONS
USGS UNITED STATES GEOLOGICAL SURVEY
UVSS UNDER-VEHICLE SURVEILLANCE SYSTEM
VOL. VOLUME
W/L, W/M, WAT WATER LINE, WATER MAIN
WSE WATER SURFACE ELEVATION
WSSC WASHINGTON SUBURBAN SANITARY COMMISSION
WTP WATER TREATMENT PLANT
YR YEAR
ZD ZONING DESIGNATION
W
OHT
GAS GAS GAS
BENCHMARK
LIMITS OF GRADING
EXISTING
DOOR LOCATION
BUILDING WALL
PROPERTY LINE
STREET CENTERLINE
CONTOURS
STORM STRUCTURE LABEL
CURB AND GUTTER
EDGE OF PAVEMENT
STORM SEWER
SANITARY SEWER
WATERMAIN
GAS LINE
UNDERGROUND ELECTRIC
OVERHEAD TELEPHONE
UNDERGROUND TELEPHONE
FENCE LINE
TRAFFIC SIGNAL POLE
WATER VALVE
UTILITY POLE
STREET LIGHT
PARKING SPACES NUMBER
FIRE HYDRANT
SIGN
SPOT SHOT
WATER METER
SANITARY STRUCTURE LABEL
TREE/BUSH
TREE LINE
TEST HOLE
X X X X
NEW
WETLANDS LINE
FIBER OPTIC LINE
BOLLARD
GWPBURIED UTILITY WARNING POST
GROUNG LIGHT
OVER HEAD WIRE
UGTUNDERGROUND TELECOM
UGT
CL
W
MAIN DOOR
GAS VALVE
TELEPHONE/TELECOM MANHOLE
SANITARY SEWER MANHOLE
STORM DRAIN MANHOLE
ELECTRIC MANHOLE
WATER MANHOLE
CLEAN OUT
RIP RAP
PENNONI SURVEY BOUNDARY
LEGEND FOR SITE / CIVIL DRAWINGS
BORING LOCATION............................. B1
EX. EVERGREEN TREE
E
G
SS
UNIDENTIFIED UTILITY
1 PRE-FINAL SUBMISSION 10-15-2021
2 MDE SUBMISSION 12-3-2021
I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No. 19185, Expiration Date: 07/01/23.
MDE No. 22-SF-0088
3 PRE - FINAL DESIGN 1-11-2022
286.31
TRAV3GPS
7.628
7.7
6.7
6.6
7.4
7.7
7.6
7.6
7.8
7.7
7.8
253.75
TRAV2GPS
262.98
TRAV1GPS
0.0
9.7
9.7 26
9.5
8.326
9.3
7.6
5.4
2.6
5.0
5 27
0 27 5 28
0 28
262 26
G A
TE
CONC
CONC WALL
CONC WALL
WOOD
STEPS
CONC WALK
POWER
EQUIPMENT
EXISTING BUILDING EXISTING BUILDING
EXISTING BUILDING
CONC CURB
CONC CURB
CONC CURB
CONC CURB
ASPHALT DRIVE
ASPHALT DRIVE
RAILING
U:
\A cc ou nt s\M
TF
AX
\M
TF
AX
- G
SA
D C
Na tio na l R ec or ds R et ain ing W all \D
ES
IG
N\ _S
HE
ET
S\ M
TF
AX
1-
CS
TE
D:
2/
/2
9:
A M, B
Y:
Na de jda
B ur diu ja
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
PR
OJ
EC
T
ST
AT
US
PENNONI ASSOCIATES INC.
1602 Village Market Blvd SE, Suite 330
Leesburg, VA 20175 T 703.777.3616 F 703.777.3725
1 PRE-FINAL SUBMISSION 10-15-2021
2 MDE SUBMISSION 12-3-2021
I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No. 19185, Expiration Date: 07/01/23.
00 20' 40'
MDE No. 22-SF-0088
3 PRE - FINAL DESIGN 1-11-2022
TRAV3GPS
7.628
7.7
6.7
6.6
7.4
7.7
7.6
7.6
7.8
7.7
7.8
253.75
TRAV2GPS
262.98
TRAV1GPS
0.0
9.7
9.7 26
9.5
8.326
9.3
7.6
5.4
2.6
5.0
5 27
0 27 5 28
0 28
262 26
G A
TE
CONC
CONC WALL
CONC WALL
WOOD
STEPS
CONC WALK
POWER
EQUIPMENT
EXISTING BUILDING EXISTING BUILDING
EXISTING BUILDING
CONC CURB
CONC CURB
CONC CURB
CONC CURB
ASPHALT DRIVE
ASPHALT DRIVE
RAILING
DEMOLISH EXISTING CURB AS NEEDED TO FACILITATE STABILIZED
CONSTRUCTION ENTRANCE. RETURN TO ORIGINAL CONDITION OR
BETTER AFTER CONSTRUCTION IS FINISHED
(SEE DRAWINGS # CS1001, CS3001 AND CS8001-CS8105.)
REMOVE AND REPLACE EXISTING RETAINING WALL
PER STRUCTURAL DRAWINGS AND SPECIFICATIONS.
REMOVE AND REPLACE EXISTING CONCRETE
TO EXISTING CONDITION OR BETTER, AS NEEDED
FOR RETAINING WALL REMOVAL AND REPLACEMENT
(SEE DRAWINGS # CS1001 AND CS3001).
DEMOLISH AND REPLACE THIS PORTION OF
EXISTING 4" SUB-DRAIN (SEE SITE PLAN)
DEMOLISH AND REMOVE THIS PORTION
OF EXISTING 4" SUB-DRAIN
PRESERVE AND CLEANOUT THIS PORTION OF
EXISTING 4" SUB-DRAIN (SEE SITE PLAN)
REMOVE AND REPLACE EXISTING CONCRETE CURB
AND GUTTER TO EXISTING CONDITION OR BETTER, AS
NEEDED FOR RETAINING WALL REMOVAL AND
REPLACEMENT (SEE DRAWINGS # CS1001 AND CS3001).
PROTECT EXISTING FIRE HYDRANT & ASSOCIATED WATER
LINE IN PLACE WTHOUT DAMAGE AND/OR REMOVE AND
REPLACE TO EXISTING CONDITION OR BETTER, AS
NEEDED FOR RETAINING WALL REMOVAL AND
REPLACEMENT (SEE DRAWINGS # CS1001 AND CS3001).
REMOVE AND REPLACE EXISTING ASPHALT PAVEMENT
TO EXISTING CONDITION OR BETTER, AS NEEDED FOR
RETAINING WALL REMOVAL AND REPLACEMENT
(SEE DRAWINGS # CS1001 AND CS3001).
PROTECT EXISTING LIGHT POST & ASSOCIATED ELECTRIC
LINE IN PLACE WTHOUT DAMAGE AND/OR REMOVE AND
REPLACE TO EXISTING CONDITION OR BETTER, AS
NEEDED FOR RETAINING WALL REMOVAL AND
REPLACEMENT (SEE DRAWINGS # CS1001 AND CS3001).
U:
\A cc ou nt s\M
TF
AX
\M
TF
AX
- G
SA
D C
Na tio na l R ec or ds R et ain ing W all \D
ES
IG
N\ _S
HE
ET
S\ M
TF
AX
1-
CS
TE
D:
2/
/2
9:
A M, B
Y:
Na de jda
B ur diu ja
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
PR
OJ
EC
T
ST
AT
US
PENNONI ASSOCIATES INC.
1602 Village Market Blvd SE, Suite 330
Leesburg, VA 20175 T 703.777.3616 F 703.777.3725
1 PRE-FINAL SUBMISSION 10-15-2021
2 MDE SUBMISSION 12-3-2021
I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No. 19185, Expiration Date: 07/01/23.
00 20' 40'
MDE No. 22-SF-0088
3 PRE - FINAL DESIGN 1-11-2022
TRAV3GPS
7.628
7.7
6.7
6.6
7.4
7.7
7.6
7.6
7.8
7.7
7.8
253.75
TRAV2GPS
262.98
TRAV1GPS
0.0
9.7
9.7 26
9.5
8.326
9.3
7.6
5.4
2.6
5.0
5 27
0 27 5 28
0 28
262 26
G A
TE
CONC
CONC WALL
CONC WALL
WOOD
STEPS
CONC WALK
POWER
EQUIPMENT
EXISTING BUILDING EXISTING BUILDING
EXISTING BUILDING
CONC CURB
CONC CURB
CONC CURB
CONC CURB
ASPHALT DRIVE
ASPHALT DRIVE
RAILING
3' WIDE CONCRETE
SIDEWALK
212.6'
239.59'
MEET AND MATCH
EXISTING
REPAIR EXISTING WALL
(SEE STRUCT.)
REMOVE AND REPLACE EXISTING RETAINING WALL
PER STRUCTURAL DRAWINGS AND SPECIFICATIONS 4" PERFORATED UNDERDRAIN PIPE
CONNECT 6" PVC
LOWER FOUNDATION
DRAIN TO EXISTING INLET
26.93'
REPLACE PORTION OF EXISTING 4" SUB-DRAIN AND
CONNECT TO NEW LOWER SUB-DRAIN. CLEAN OUT
PORTION OF EXISTING SUB-DRAIN TO REMAIN
PRESERVE AND CLEANOUT THIS PORTION
OF EXISTING 4" SUB-DRAIN
REMOVE AND REPLACE EXISTING CONCRETE CURB
AND GUTTER TO EXISTING CONDITION OR BETTER, AS
NEEDED FOR RETAINING WALL REMOVAL AND
REPLACEMENT (SEE DRAWINGS # CS0501 AND CS3001).
PROTECT EXISTING FIRE HYDRANT & ASSOCIATED WATER
LINE IN PLACE WTHOUT DAMAGE AND/OR REMOVE AND
REPLACE TO EXISTING CONDITION OR BETTER, AS NEEDED
FOR RETAINING WALL REMOVAL AND REPLACEMENT (SEE
DRAWINGS # CS0501 AND CS3001).
PROTECT EXISTING LIGHT POST & ASSOCIATED ELECTRIC
LINE IN PLACE WTHOUT DAMAGE AND/OR REMOVE AND
REPLACE TO EXISTING CONDITION OR BETTER, AS
NEEDED FOR RETAINING WALL REMOVAL AND REPLACEMENT
(SEE DRAWINGS # CS0501 AND CS3001).
FINISHED GRADE IN GRASS AREA ON
HIGH SIDE OF WALL SHALL BE 1-FOOT
MIN. BELOW TOP OF WALL ELEVATION.
C1
C1
EX.=PROP.
TW=269.31' EX.=PROP.
TW=288.87'
EX.=PROP.
TW=288.93'
EX.=PROP.TW=288.87'
(AS SHOWN ON SECTION
C1 BELOW) EX.=PROP.
TW=288.94'
CO
CO
CO
WALL SECTION
SC: 1" = 5'
3'-6" RAIL
MATCH EXISTING
(SEE STRUCTURAL)
.0
4'
EXISTING TOP OF CURB (TC)
APPROXIMATE RANGE OF TC
VARIES FROM 261' - 266'±
ENGINEERED STRUCTURAL FILL PER PROJECT SPECIFICATIONS AND GEOTECHNICAL
REPORT (SEE ALSO GENERAL NOTES ON DRAWING # CS0002)
REMOVE AND REPLACE
EXISTING CONCRETE
CURB/SIDEWALK TO
EXISTING CONDITION OR
BETTER (ALSO SEE
STRUCTURAL).
EXISTING ROAD
BOTTOM OF FOOTING=265.50'
(PER RECORD DRAWINGS). CONTRACTOR TO CONFIRM DEPTH AND
SIZE OF EXISTING FOOTING AND NOTIFY THE OWNER AND ENGINEER
OF RESULTS PRIOR TO PROCEEDING WITH CONSTRUCTION.
CS1001
C1
PROPOSED RETAINING WALL
(SEE STRUCTURAL)
1.
' P E
R R
E C
O R
D D
O C
S
SLOPE VARIES
7.5% - 24%±
(SEE SITE PLAN)
FINISHED GRADE = 268.40' **. (FINISHED
GRADE VARIES FROM 267.5' - 268.5'±
ACROSS LENGTH OF WALL)
28.0'
CS3001
P1 ASPHALT PAVEMENT
CS3001
P2
LOWER LEVEL 4-INCH PERFORATED UNDERDRAIN
TO DISCHARGE TO 8-INCH SOLID PVC STORM DRAIN
TO DISCHARGE TO STORM DRAIN INLET (SEE PLAN)
BOTTOM OF PIPE MIN. 6" ABOVE BOTTOM OF
DRAINAGE AGGREGATE LAYER.
½ -INCH JOINT WITH
COMPRESSIBLE FILLER
AND SEALANT
12 INCHES MINIMUM OF FREE DRAINAGE AGGREGATE,
WRAPPED IN FILTER FABRIC TO PREVENT MIGRATION
OF BACKFILL INTO DRAINAGE AGGREGATE
GCP APPLIED TECHNOLOGIES (HTTPS://GCPAT.COM) PROCOR®
BELOW-GRADE FLUID APPLIED WATERPROOFING OR APPROVED
EQUAL; AND GCPAT HYDRODUCT® DRAINAGE COMPOSITES
PROTECTION AND DRAINAGE BOARD OR APPROVED EQUAL
UPPER LEVEL 4-INCH PERFORATED UNDERDRAIN TO DISCHARGE TO
4-INCH SOLID PVC WEEP HOLES TO DAYLIGHT ON DOWNHILL SIDE/FACE
OF WALL AT 10 FEET ON CENTER. COVER WEEP HOLES WITH RODENT
SCREEN WHERE THEY COME THROUGH WALL. ALL WEEP HOLES SHALL
DAYLIGHT 6 INCHES MIN. ABOVE FINISHED GRADE
1.
0'
ENGINEERED STRUCTURAL FILL AND ULTRA LIGHTWEIGHT (UL) FOAMED
GLASS AGGREGATE (FGA), PER UL-FGA - AEROAGGREGATES OF NORTH
AMERICA, LLC (AEROAGGNA.COM)
HTTPS://WWW.AEROAGGNA.COM/ABOUT-ULFGA), OR APPROVED EQUAL
(SEE ALSO STRUCTURAL DRAWINGS AND PROJECT SPECIFICATIONS).
M
IN
.E M
B E
D M
E N
T= 2'
TOP OF WALL ELEVATION = 288.87' **
AS NOTED ON PLAN
.4
7'
1.
U:
\A cc ou nt s\M
TF
AX
\M
TF
AX
- G
SA
D C
Na tio na l R ec or ds R et ain ing W all \D
ES
IG
N\ _S
HE
ET
S\ M
TF
AX
1-
CS
TE
D:
2/
/2
9:
A M, B
Y:
Na de jda
B ur diu ja
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
PR
OJ
EC
T
ST
AT
US
PENNONI ASSOCIATES INC.
1602 Village Market Blvd SE, Suite 330
Leesburg, VA 20175 T 703.777.3616 F 703.777.3725
00 20' 40'
1 PRE-FINAL SUBMISSION 10-15-2021
2 MDE SUBMISSION 12-3-2021
I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No. 19185, Expiration Date: 07/01/23.
FILTER FABRIC - TO BE PROVIDED PER C1 - WALL SECTION, AND BETWEEN STRUCTURAL FILL
AND UL-FGA, AS FOLLOWS:
a. FABRIC SHALL BE A NONWOVEN FABRIC CONSISTING OF LONG CHAIN POLYMERIC FILAMENTS
OR YARNS OF POLYPROPYLENE, POLYESTER, POLYAMIDE, OR POLYVINYLIDENE-CHLORIDE
FORMED INTO A STABLE NETWORK.
b. FABRIC SHALL BE INERT TO CHEMICALS COMMONLY ENCOUNTERED IN SOIL AND TO
HYDROCARBONS.
c. FABRIC SHALL BE RESISTANT TO MILDEW, ROT, AND INSECT AND RODENT ATTACKS.
d. FABRIC SHALL CONTAIN ULTRAVIOLET RAY INHIBITORS AND STABILIZERS AND BE SUITABLE
FOR USE AT TEMPERATURES OF 0°F TO 120°F.
e. FABRIC SHALL CONFORM TO THE FOLLOWING TEST CRITERIA:
TEST AND METHOD SPECIFICATION LIMITS
GRAB TENSILE STRENGTH, ASTM D 1682, LBS. MIN. 90
TENSILE ELONGATION, ASTM D 1682, % MIN 20
BURST STRENGTH, ASTM D 3786, PSI MIN. 140
TRAPEZOIDAL TEAR STRENGTH, ASTM D 1117, PSI MIN. 45
EQUIVALENT OPENING SIZE, U.S. STANDARD SIEVE SIZE, CW-02215 USACE 40-100 (PER PLAN)
FLOW RATE, AASHTO M 2281 APPENDIX, GPM/SQ FT MIN. 40
COEFFICIENT PERMEABILITY, AASHTO M 228 APPENDIX, CM/SEC MIN. .05
f. FABRIC SECURING PINS SHALL BE 3/16-INCH DIAMETER STEEL, POINTED AT ONE END, AND
FABRICATED AT THE OTHER END WITH A HEAD TO RETAIN A STEEL WASHER HAVING AN
OUTSIDE DIAMETER OF NOT LESS THAN 1 1/2 INCHES. PIN LENGTH SHALL BE AT LEAST 18 INCHES.
MDE No. 22-SF-0088
3 PRE - FINAL DESIGN 1-11-2022
cc ou nt s\M
TF
AX
\M
TF
AX
- G
SA
D C
Na tio na l R ec or ds R et ain ing W all \D
ES
IG
N\ _S
HE
ET
S\ M
TF
AX
1-
CS
TE
D:
2/
/2
9:
A M, B
Y:
Na de jda
B ur diu ja
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
PR
OJ
EC
T
ST
AT
US
PENNONI ASSOCIATES INC.
1602 Village Market Blvd SE, Suite 330
Leesburg, VA 20175 T 703.777.3616 F 703.777.3725
1 PRE-FINAL SUBMISSION 10-15-2021
2 MDE SUBMISSION 12-3-2021
3 PRE - FINAL DESIGN 1-11-2022
MDE No. 22-SF-0088
TRAV3GPS
7.628
7.7
6.7
6.6
7.4
7.7
7.6
7.6
7.8
7.7
7.8
253.75
TRAV2GPS
262.98
TRAV1GPS
0.0
9.7
9.7 26
9.5
8.326
9.3
7.6
5.4
2.6
5.0
5 27
0 27 5 28
0 28
262 26
G A
TE
CONC
CONC WALL
CONC WALL
WOOD
STEPS
CONC WALK
POWER
EQUIPMENT
EXISTING BUILDING EXISTING BUILDING
EXISTING BUILDING
CONC CURB
CONC CURB
CONC CURB
CONC CURB
ASPHALT DRIVE
ASPHALT DRIVE
RAILING
212.6'
239.59'
26.93'
C1
C1
EX.=PROP.
TW=269.31' EX.=PROP.
TW=288.87'
EX.=PROP.
TW=288.93'
EX.=PROP.TW=288.87'
(AS SHOWN ON SECTION
C1 BELOW) EX.=PROP.
TW=288.94'
CO
CO
CO
PRESERVE AND CLEANOUT THIS PORTION OF
EXISTING 4" SUB-DRAIN (SEE SITE PLAN)
U:
\A cc ou nt s\M
TF
AX
\M
TF
AX
- G
SA
D C
Na tio na l R ec or ds R et ain ing W all \D
ES
IG
N\ _S
HE
ET
S\ M
TF
AX
1-
CS
TE
D:
2/
/2
9:
A M, B
Y:
Na de jda
B ur diu ja
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
PR
OJ
EC
T
ST
AT
US
PENNONI ASSOCIATES INC.
1602 Village Market Blvd SE, Suite 330
Leesburg, VA 20175 T 703.777.3616 F 703.777.3725
12"
TYPICAL PAVEMENT JOINT SECTION
1 PRE-FINAL SUBMISSION 10-15-2021
2 MDE SUBMISSION 12-3-2021
I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No. 19185, Expiration Date: 07/01/23.
00 20' 40'
FULL DEPTH ASPHALT PAVEMENT
CONCRETE SIDEWALK SECTION
MDE No. 22-SF-0088
3 PRE - FINAL DESIGN 1-11-2022
TRAV3GPS
7.628
7.7
6.7
6.6
7.4
7.7
7.6
7.6
7.8
7.7
7.8
253.75
TRAV2GPS
262.98
TRAV1GPS
0.0
9.7
9.7 26
9.5
8.326
9.3
7.6
5.4
2.6
5.0
5 27
0 27 5 28
0 28
262 26
G A
TE
CONC
CONC WALL
CONC WALL
WOOD
STEPS
CONC WALK
POWER
EQUIPMENT
EXISTING BUILDING EXISTING BUILDING
EXISTING BUILDING
CONC CURB
CONC CURB
CONC CURB
CONC CURB
ASPHALT DRIVE
ASPHALT DRIVE
RAILING
TO EX. STR. #10
Area = 0.44 Ac
TO EX. STR. 11
Area = 0.22 Ac
TO EX. STR. #12
Area = 0.56 Ac
TO EX. STR. #13
Area = 0.47 Ac
LOCATION OF GENERAL CONTRACTOR STORAGE /
LAY-DOWN AREA APPROXIMATELY 30' X 60'. THE
EXACT LIMITS ARE TO BE COORDINATED ON SITE
WITH THE GOVERNMENT AND MDE.
PROVIDE FENCING AROUND STAGING AREA, KEEP
CLEAN AND RESTORE TO ORIGINAL CONDITION OR
BETTER AT COMPLETION OF PROJECT.
WATER SOURCE VIA WATER TRUCK. WASH
WATER TO BE DIRECTED TO INLET PROTECTION.
SILT FENCE
STANDARD SYMBOL
FILTER LOG
E & S LEGEND
STABILIZED CONSTRUCTION
ENTRANCE W/ WASHRACK
STANDARD SYMBOL
CURB INLET PROTECTION
STANDARD SYMBOL
STANDARD SYMBOL
REMOVABLE PUMPING STATION
STANDARD SYMBOL
SUMP PIT
STANDARD SYMBOL
PORTABLE SEDIMENT TANK
STANDARD SYMBOL
E & S LEGEND
DRAINAGE DIVIDE
DRAINAGE AREA
CALLOUT
LIMIT OF DISTURBANCE
FILTER LOG
STANDARD SYMBOL
ONSITE CONCRETE WASHOUT
STRUCTURE
STANDARD SYMBOL
U:
\A cc ou nt s\M
TF
AX
\M
TF
AX
- G
SA
D C
Na tio na l R ec or ds R et ain ing W all \D
ES
IG
N\ _S
HE
ET
S\ M
TF
AX
1-
CS
TE
D:
2/
/2
1:
P M, B
Y:
Na de jda
B ur diu ja
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
PR
OJ
EC
T
ST
AT
US
PENNONI ASSOCIATES INC.
1602 Village Market Blvd SE, Suite 330
Leesburg, VA 20175 T 703.777.3616 F 703.777.3725
1 PRE-FINAL SUBMISSION 10-15-2021
2 MDE SUBMISSION 12-3-2021
I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No. 19185, Expiration Date: 07/01/23.
00 20' 40'
GENERAL NOTES FOR EROSION AND SEDIMENT
CONTROL PLANS:
1 - NO DISTURBED AREAS SHALL BE LEFT
UNSTABILIZED OVERNIGHT UNLESS THE RUNOFF IS
DIRECTED TO AN MDE APPROVED SEDIMENT
CONTROL DEVICE.
2 - SOIL EROSION & SEDIMENT CONTROL SHALL BE
STRICTLY ENFORCED.
3 - CONSTRUCTION VEHICLES SHALL BE WASHED
ONSITE AS NEEDED TO PREVENT ANY MUD,
SEDIMENT, OR SILTATION TO BE TRACKED OUTSIDE
OF CONSTRUCTION AREA.
NOTE: THIS SHEET IS FOR EROSION AND SEDIMENT
CONTROL ONLY. SEE OTHER SHEETS FOR SITE
PLANS AND DETAILS.
MDE No. 22-SF-0088
3 PRE - FINAL DESIGN 1-11-2022
NOTE:
1. THE WORK SHOWN IN THIS AREA SHALL BE DONE USING THE METHOD OF 'SAME DAY
STABILIZATION'. NO MORE LAND AREA [OR LENGTH OF TRENCH, SWALE, CHANNEL, ETC.] SHALL BE DISTURBED THAN CAN BE STABILIZED BY THE END OF THE SAME WORKDAY. ALL DISTURBED
AREAS THAT DO NOT DRAIN TO A SEDIMENT CONTROL DEVICE SHALL BE STABILIZED BY THE
END OF THE SAME WORKDAY. NO DISTURBED AREA SHALL BE LEFT UNSTABILIZED OVERNIGHT
UNLESS THE RUNOFF IS DIRECTED TO AN MDE APPROVED SEDIMENT CONTROL DEVICE. FOR
WORK ACTIVITIES IN PAVED AREAS, THE STONE BASE COURSE LAYER MUST BE PLACED BY THE
END OF THE SAME DAY TO QUALIFY AS SAME DAY STABILIZATION.
2. DISCHARGE FROM SUMP PIT (SP) VIA A REMOVABLE PUMPING STATION (RPS) SHALL BE
DISCHARGE TO EITHER A PORTABLE SEDIMENT TANK (PST) AND/OR A FILTER BAG (FB).
THE LOCATION OF THE PORTABLE SEDIMENT TANK (PST) AND/OR FILTER BAG (FB) MAY
VARY AND/OR BE ADJUSTED WITH PRIOR WRITTEN APPROVAL FROM THE OWNER, THE
ENGINEER, AND THE MDE INSPECTOR.
TRAV3GPS
7.628
7.7
6.7
6.6
7.4
7.7
7.6
7.6
7.8
7.7
7.8
253.75
TRAV2GPS
262.98
TRAV1GPS
0.0
9.7
9.7 26
9.5
8.326
9.3
7.6
5.4
2.6
5.0
5 27
0 27 5 28
0 28
262 26
G A
TE
CONC
CONC WALL
CONC WALL
WOOD
STEPS
CONC WALK
POWER
EQUIPMENT
EXISTING BUILDING EXISTING BUILDING
EXISTING BUILDING
CONC CURB
CONC CURB
CONC CURB
CONC CURB
ASPHALT DRIVE
ASPHALT DRIVE
RAILING
C1
C1
CO
CO
CO
TO EX. STR. #10
Area = 0.44 Ac
TO EX. STR. 11
Area = 0.22 Ac
TO EX. STR. #12
Area = 0.56 Ac
TO EX. STR. #13
Area = 0.47 Ac
WATER SOURCE VIA WATER TRUCK. WASH
WATER TO BE DIRECTED TO INLET PROTECTION.
SEE NOTE NELOW
LOCATION OF GENERAL CONTRACTOR STORAGE /
LAY-DOWN AREA APPROXIMATELY 30' X 60'. THE
EXACT LIMITS ARE TO BE COORDINATED ON SITE
WITH THE GOVERNMENT AND MDE.
PROVIDE FENCING AROUND STAGING AREA, KEEP
CLEAN AND RESTORE TO ORIGINAL CONDITION OR
BETTER AT COMPLETION OF PROJECT.
SILT FENCE
STANDARD SYMBOL
FILTER LOG
E & S LEGEND
STABILIZED CONSTRUCTION
ENTRANCE W/ WASHRACK
STANDARD SYMBOL
CURB INLET PROTECTION
STANDARD SYMBOL
STANDARD SYMBOL
REMOVABLE PUMPING STATION
STANDARD SYMBOL
SUMP PIT
STANDARD SYMBOL
PORTABLE SEDIMENT TANK
STANDARD SYMBOL
E & S LEGEND
FILTER LOG
STANDARD SYMBOL
DRAINAGE DIVIDE
DRAINAGE AREA
CALLOUT
LIMIT OF DISTURBANCE
ONSITE CONCRETE WASHOUT
STRUCTURE
STANDARD SYMBOL
U:
\A cc ou nt s\M
TF
AX
\M
TF
AX
- G
SA
D C
Na tio na l R ec or ds R et ain ing W all \D
ES
IG
N\ _S
HE
ET
S\ M
TF
AX
1-
CS
TE
D:
2/
/2
1:
P M, B
Y:
Na de jda
B ur diu ja
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
PR
OJ
EC
T
ST
AT
US
PENNONI ASSOCIATES INC.
1602 Village Market Blvd SE, Suite 330
Leesburg, VA 20175 T 703.777.3616 F 703.777.3725
1 PRE-FINAL SUBMISSION 10-15-2021
2 MDE SUBMISSION 12-3-2021
I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No. 19185, Expiration Date: 07/01/23.
00 20' 40'
GENERAL NOTES FOR EROSION AND SEDIMENT
CONTROL PLANS:
1 - NO DISTURBED AREAS SHALL BE LEFT
UNSTABILIZED OVERNIGHT UNLESS THE RUNOFF IS
DIRECTED TO AN MDE APPROVED SEDIMENT
CONTROL DEVICE.
2 - SOIL EROSION & SEDIMENT CONTROL SHALL BE
STRICTLY ENFORCED.
3 - CONSTRUCTION VEHICLES SHALL BE WASHED
ONSITE AS NEEDED TO PREVENT ANY MUD,
SEDIMENT, OR SILTATION TO BE TRACKED OUTSIDE
OF CONSTRUCTION AREA.
NOTE: THIS SHEET IS FOR EROSION AND SEDIMENT
CONTROL ONLY. SEE OTHER SHEETS FOR SITE
PLANS AND DETAILS.
MDE No. 22-SF-0088
NOTE:
1. THE WORK SHOWN IN THIS AREA SHALL BE DONE USING THE METHOD OF 'SAME DAY
STABILIZATION'. NO MORE LAND AREA [OR LENGTH OF TRENCH, SWALE, CHANNEL, ETC.] SHALL BE DISTURBED THAN CAN BE STABILIZED BY THE END OF THE SAME WORKDAY. ALL DISTURBED
AREAS THAT DO NOT DRAIN TO A SEDIMENT CONTROL DEVICE SHALL BE STABILIZED BY THE
END OF THE SAME WORKDAY. NO DISTURBED AREA SHALL BE LEFT UNSTABILIZED OVERNIGHT
UNLESS THE RUNOFF IS DIRECTED TO AN MDE APPROVED SEDIMENT CONTROL DEVICE. FOR
WORK ACTIVITIES IN PAVED AREAS, THE STONE BASE COURSE LAYER MUST BE PLACED BY THE
END OF THE SAME DAY TO QUALIFY AS SAME DAY STABILIZATION.
2. DISCHARGE FROM SUMP PIT (SP) VIA A REMOVABLE PUMPING STATION (RPS) SHALL BE
DISCHARGE TO EITHER A PORTABLE SEDIMENT TANK (PST) AND/OR A FILTER BAG (FB).
THE LOCATION OF THE PORTABLE SEDIMENT TANK (PST) AND/OR FILTER BAG (FB) MAY
VARY AND/OR BE ADJUSTED WITH PRIOR WRITTEN APPROVAL FROM THE OWNER, THE
ENGINEER, AND THE MDE INSPECTOR.
3 PRE - FINAL DESIGN 1-11-2022
NOTE: CUT SOIL MAY BE RE-USED IF TESTED AND CONFIRMED TO
MEET MDE SOIL AND GEOTECHNICAL REPORT SOIL REQUIREMENTS.
cc ou nt s\M
TF
AX
\M
TF
AX
- G
SA
D C
Na tio na l R ec or ds R et ain ing W all \D
ES
IG
N\ _S
HE
ET
S\ M
TF
AX
1-
CS
TE
D:
2/
/2
1:
P M, B
Y:
Na de jda
B ur diu ja
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
PR
OJ
EC
T
ST
AT
US
PENNONI ASSOCIATES INC.
1602 Village Market Blvd SE, Suite 330
Leesburg, VA 20175 T 703.777.3616 F 703.777.3725
EROSION AND SEDIMENT CONTROL GENERAL NOTES
1. THE CONTRACTOR SHALL NOTIFY MDE AT (410) 537-3510 SEVEN (7) DAYS BEFORE COMMENCING ANY LAND DISTURBING ACTIVITY AND, UNLESS WAIVED BY MDE, SHALL BE REQUIRED TO HOLD A PRE-CONSTRUCTION MEETING BETWEEN PROJECT REPRESENTATIVES AND A REPRESENTATIVE OF MDE.
2. THE CONTRACTOR SHALL NOTIFY MDE IN WRITING AND BY TELEPHONE AT THE FOLLOWING POINTS:
A. THE REQUIRED PRE-CONSTRUCTION MEETING.
B. FOLLOWING INSTALLATION OF SEDIMENT CONTROL MEASURES.
C. PRIOR TO REMOVAL OR MODIFICATION OF ANY SEDIMENT CONTROL STRUCTURE(S).
D. PRIOR TO REMOVAL OF ALL SEDIMENT CONTROL DEVICES.
E. PRIOR TO FINAL ACCEPTANCE.
3. THE PLAN APPROVAL LETTER, APPROVED EROSION AND SEDIMENT CONTROL PLANS, DAILY LOG BOOKS, AND TEST REPORTS SHALL BE AVAILABLE AT THE SITE FOR INSPECTION BY DULY AUTHORIZED OFFICIALS OF MDE AND THE AGENCY RESPONSIBLE FOR THE PROJECT.
4. THE CONTRACTOR SHALL CONSTRUCT ALL EROSION AND SEDIMENT CONTROL MEASURES PER THE APPROVED PLAN AND CONSTRUCTION SEQUENCE AND SHALL HAVE THEM INSPECTED AND APPROVED BY THE MDE INSPECTOR PRIOR TO BEGINNING ANY OTHER LAND DISTURBANCES. MINOR SEDIMENT CONTROL DEVICE LOCATION ADJUSTMENTS MAY BE MADE IN THE FIELD WITH THE APPROVAL OF THE MDE INSPECTOR. THE CONTRACTOR SHALL ENSURE THAT ALL RUNOFF FROM DISTURBED AREAS IS DIRECTED TO THE SEDIMENT CONTROL DEVICES AND SHALL NOT REMOVE ANY EROSION OR SEDIMENT CONTROL MEASURE WITHOUT PRIOR PERMISSION FROM MDE INSPECTOR. THE CONTRACTOR SHALL OBTAIN PRIOR AGENCY AND MDE APPROVAL FOR MODIFICATIONS
TO THE EROSION AND SEDIMENT CONTROL PLAN AND/OR SEQUENCE OF CONSTRUCTION.
5. THE MDE INSPECTOR HAS THE OPTION OF REQUIRING ADDITIONAL SAFETY OR SEDIMENT CONTROL MEASURES, IF DEEMED NECESSARY.
6. THE CONTRACTOR SHALL PROTECT ALL POINTS OF CONSTRUCTION INGRESS AND EGRESS TO PREVENT THE DEPOSITION OF MATERIALS ONTO PUBLIC
ROADS. ALL MATERIALS DEPOSITED ONTO PUBLIC ROADS SHALL BE REMOVED IMMEDIATELY.
7. THE CONTRACTOR SHALL INSPECT DAILY AND MAINTAIN CONTINUOUSLY IN AN EFFECTIVE OPERATING CONDITION ALL EROSION AND SEDIMENT CONTROL MEASURES UNTIL SUCH TIME AS THEY ARE REMOVED WITH PRIOR PERMISSION FROM THE MDE INSPECTOR.
8. EROSION AND SEDIMENT CONTROL FOR UTILITY CONSTRUCTION SHALL BE PROVIDED IN ACCORDANCE WITH APPROVED PLANS. UTILITY CONSTRUCTION SHALL ONLY BE FOR AREAS WITHIN THE DELINEATED LIMIT OF DISTURBANCE. CALL "MISS UTILITY" AT 1-800-257-7777 48 HOURS PRIOR TO THE START OF WORK.
WHEN SAME DAY STABILIZATION IS APPROVED:
A. EXCAVATED TRENCH MATERIAL SHALL BE PLACED ON THE HIGH SIDE OF THE TRENCH.
B. TRENCHES FOR UTILITY INSTALLATION SHALL BE BACKFILLED, COMPACTED, AND STABILIZED AT THE END OF EACH WORKING DAY. NO MORE TRENCH
SHALL BE OPENED THAN CAN BE COMPLETED THE SAME DAY.
9. ALL WATER REMOVED FROM EXCAVATED AREAS SHALL BE PASSED THROUGH AN MDE APPROVED DEWATERING PRACTICE OR PUMPED TO A SEDIMENT TRAP OR BASIN PRIOR TO DISCHARGE TO A FUNCTIONAL STORM DRAIN SYSTEM OR TO STABLE GROUND SURFACE.
10. CONCRETE WASHOUT STRUCTURES SHALL BE USED WHEN CONCRETE TRUCKS, DRUMS, PUMPS, CHUTES, OR OTHER EQUIPMENT IS RINSED OR CLEANED
ON-SITE.
11. CONSTRUCTION ACTIVITIES PRODUCING DUST SHALL IMPLEMENT CONTROL MEASURES TO AVOID THE SUSPENSION OF DUST PARTICLES AND/OR PREVENT
DUST FROM BLOWING OFF-SITE OR TO AREAS WITHOUT TREATMENT.
12. FOLLOWING INITIAL SOIL DISTURBANCE OR RE-DISTURBANCE, PERMANENT OR TEMPORARY STABILIZATION SHALL BE COMPLETED WITHIN:
A. THREE (3) CALENDAR DAYS AS TO THE SURFACE OF ALL PERIMETER CONTROLS, DIKES, SWALES, DITCHES, PERIMETER SLOPES, AND ALL SLOPES
STEEPER THAN 3 HORIZONTAL TO 1 VERTICAL (3:1); AND
B. SEVEN (7) CALENDAR DAYS AS TO ALL OTHER DISTURBED OR GRADED AREAS ON THE PROJECT SITE NOT UNDER ACTIVE GRADING.
13. VEGETATIVE STABILIZATION SHALL BE PERFORMED IN ACCORDANCE WITH THE 2011 MARYLAND STANDARDS AND SPECIFICATIONS FOR SOIL EROSION AND SEDIMENT CONTROL. REFER TO APPROPRIATE SPECIFICATIONS FOR TEMPORARY SEEDING, PERMANENT SEEDING, MULCHING, SODDING, AND GROUND
COVERS.
14. WHEN SEEDING, ALL DISTURBED AREAS WITH SLOPES FLATTER THAN 2:1 SHALL BE STABILIZED WITH 4 INCHES OF TOPSOIL, SEED, AND MULCH. ALL DISTURBED AREAS WITH SLOPES 2:1 OR STEEPER SHALL BE STABILIZED WITH MATTING OVER 2 INCHES OF TOPSOIL AND SEED.
15. ALL SEDIMENT BASINS, TRAP EMBANKMENTS AND SLOPES, PERIMETER DIKES, SWALES AND ALL DISTURBED SLOPES STEEPER OR EQUAL TO 3:1 SHALL BE STABILIZED WITH SEED AND ANCHORED STRAW MULCH, SOD, OR OTHER APPROVED STABILIZATION MEASURES, AS SOON AS POSSIBLE BUT NO LATER THAN THREE (3) CALENDAR DAYS AFTER ESTABLISHMENT. ALL AREAS DISTURBED OUTSIDE OF THE PERIMETER SEDIMENT CONTROL SYSTEM SHALL BE MINIMIZED.
MAINTENANCE SHALL BE PERFORMED AS NECESSARY TO ENSURE CONTINUED STABILIZATION.
EROSION AND SEDIMENT CONTROL GENERAL NOTES (CONT.)
16. PERMANENT SWALES OR OTHER POINTS OF CONCENTRATED WATER FLOW SHALL BE STABILIZED WITH SEED AND AN APPROVED EROSION CONTROL MATTING, SOD, RIP-RAP, OR OTHER APPROVED STABILIZATION MEASURES.
17. FOR STOCKPILE SLOPES STEEPER THAN 3 HORIZONTAL TO 1 VERTICAL (3:1), THE CONTRACTOR SHALL APPLY SEED AND ANCHORED STRAW MULCH, SOD, OR OTHER APPROVED STABILIZATION MEASURES TO THE FACE OF THE STOCKPILE WITHIN THREE (3) CALENDAR DAYS OF ACTIVITY HAVING CEASED ON THE RESPECTIVE FACE. FOR SLOPES 3:1 OR FLATTER, THE CONTRACTOR SHALL APPLY STABILIZATION MEASURES TO THE FACE OF THE STOCKPILE WITHIN SEVEN
(7) CALENDAR DAYS OF ACTIVITY HAVING CEASED ON THE RESPECTIVE FACE. MAINTENANCE SHALL BE PERFORMED AS NECESSARY TO ENSURE CONTINUED
STABILIZATION.
18. FOR FINISHED GRADING, THE CONTRACTOR SHALL PROVIDE ADEQUATE GRADIENTS TO PREVENT WATER FROM PONDING FOR MORE THAN TWENTY-FOUR (24) HOURS AFTER THE END OF A RAINFALL EVENT. DRAINAGE COURSES AND SWALE FLOW AREAS MAY TAKE AS LONG AS FORTY-EIGHT (48) HOURS AFTER THE END OF A RAINFALL EVENT TO DRAIN. AREAS DESIGNED TO HAVE STANDING WATER SHALL NOT BE REQUIRED TO MEET THIS REQUIREMENT.
19. WHERE DEEMED APPROPRIATE BY THE ENGINEER OR INSPECTOR, SEDIMENT BASINS AND TRAPS MAY NEED TO BE SURROUNDED WITH AN APPROVED SAFETY FENCE. THE FENCE MUST CONFORM TO LOCAL ORDINANCES AND REGULATIONS. THE DEVELOPER OR OWNER SHALL CHECK WITH LOCAL BUILDING OFFICIALS ON APPLICABLE SAFETY REQUIREMENTS. WHERE SAFETY FENCE IS DEEMED APPROPRIATE AND LOCAL ORDINANCES DO NOT SPECIFY FENCING SIZES AND TYPES, THE FOLLOWING SHALL BE USED AS A MINIMUM STANDARD: THE SAFETY FENCE SHALL BE MADE OF WELDED WIRE AND AT LEAST 42 INCHES HIGH, HAVE POSTS SPACED NO FARTHER APART THAN 8 FEET, HAVE MESH OPENINGS NO GREATER THAN 2 INCHES IN WIDTH AND 4 INCHES IN HEIGHT WITH A MINIMUM OF 14 GAUGE WIRE. SAFETY FENCE SHALL BE MAINTAINED AND IN GOOD CONDITION AT ALL TIMES.
20. ALL SEDIMENT TRAP DEPTH DIMENSIONS ARE RELATIVE TO THE OUTLET ELEVATION. ALL TRAPS SHALL HAVE A STABLE OUTFALL. ALL TRAPS AND BASINS
SHALL HAVE STABLE INFLOW POINTS.
21. SEDIMENT SHALL BE REMOVED AND THE TRAP OR BASIN RESTORED TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE QUARTER OF THE TOTAL DEPTH OF THE TRAP OR BASIN. TOTAL DEPTH SHALL BE MEASURED FROM THE TRAP OR BASIN BOTTOM TO THE CREST OF THE
OUTLET.
22. SEDIMENT REMOVED FROM TRAPS (AND BASINS) SHALL BE PLACED AND STABILIZED IN APPROVED AREAS, BUT NOT WITHIN A FLOODPLAIN, WETLAND OR TREE-SAVE AREA. WHEN PUMPING SEDIMENT LADEN WATER, THE DISCHARGE SHALL BE DIRECTED TO AN MDE APPROVED SEDIMENT TRAPPING DEVICE PRIOR TO RELEASE FROM THE SITE. A SUMP PIT MAY BE USED IF SEDIMENT TRAPS THEMSELVES ARE BEING PUMPED OUT.
23. PRIOR TO REMOVAL OF SEDIMENT CONTROL MEASURES, THE CONTRACTOR SHALL STABILIZE AND HAVE ESTABLISHED PERMANENT STABILIZATION FOR ALL CONTRIBUTORY DISTURBED AREAS USING SOD OR AN APPROVED PERMANENT SEED MIXTURE WITH REQUIRED SOIL AMENDMENTS AND AN APPROVED ANCHORED MULCH. WOOD FIBER MULCH MAY ONLY BE USED IN SEEDING SEASON WHERE THE SLOPE DOES NOT EXCEED 10% AND GRADING HAS BEEN DONE TO PROMOTE SHEET FLOW DRAINAGE. AREAS BROUGHT TO FINISHED GRADE DURING THE SEEDING SEASON SHALL BE PERMANENTLY STABILIZED AS SOON AS POSSIBLE, BUT NOT LATER THAN THREE (3) CALENDAR DAYS AFTER ESTABLISHMENT FOR SLOPES STEEPER THAN 3 HORIZONTAL TO 1 VERTICAL (3:1) AND SEVEN (7) CALENDAR DAYS FOR FLATTER SLOPES. WHEN PROPERTY IS BROUGHT TO FINISHED GRADE DURING THE MONTHS OF NOVEMBER THROUGH FEBRUARY, AND PERMANENT STABILIZATION IS FOUND TO BE IMPRACTICAL, TEMPORARY SEED AND ANCHORED STRAW MULCH SHALL BE APPLIED TO DISTURBED AREAS. THE FINAL PERMANENT STABILIZATION OF SUCH PROPERTY SHALL BE APPLIED BY MARCH 15 OR EARLIER IF GROUND AND WEATHER
CONDITIONS ALLOW.
24. TEMPORARY SEDIMENT CONTROL DEVICES SHALL BE REMOVED WITH PERMISSION OF THE MDE INSPECTOR WITHIN THIRTY (30) CALENDAR DAYS FOLLOWING ESTABLISHMENT OF PERMANENT STABILIZATION IN ALL CONTRIBUTORY DRAINAGE AREAS. UPON REMOVAL OF SEDIMENT CONTROL DEVICES, THE AREA DISTURBED BY REMOVAL SHALL BE STABILIZED WITH TOPSOIL, SEED, AND MULCH, OR AS SPECIFIED, WITHIN 24 HOURS OF SAID REMOVAL. STORMWATER MANAGEMENT STRUCTURES USED TEMPORARILY FOR SEDIMENT CONTROL SHALL BE CONVERTED TO THE PERMANENT CONFIGURATION WITHIN THIS TIME
PERIOD AS WELL.
25. OFF-SITE SPOIL OR BORROW AREAS ON STATE OR FEDERAL PROPERTY SHALL HAVE PRIOR APPROVAL BY MDE AND OTHER APPLICABLE STATE, FEDERAL, AND LOCAL AGENCIES; OTHERWISE APPROVAL SHALL BE GRANTED BY THE LOCAL AUTHORITIES. ALL WASTE AND BORROW AREAS OFF-SITE SHALL BE
PROTECTED BY SEDIMENT CONTROL MEASURES AND STABILIZED.
26. SITE INFORMATION:
A. AREA DISTURBED _______________ACRES
B. TOTAL CUT _______________CUBIC YARDS
C. TOTAL FILL _______________CUBIC YARDS
D. OFF-SITE WASTE / BORROW AREA LOCATION _____________________TBD
SEQUENCE OF CONSTRUCTION
1. THE CONTRACTOR SHALL NOTIFY THE MARYLAND DEPARTMENT OF ENVIRONMENT, WATER SCIENCE ADMINISTRATION (MDE/WSA) BY TELEPHONE AT (410) 537-3510 AND IN WRITING SEVEN (7) DAYS BEFORE COMMENCING ANY LAND DISTURBING ACTIVITIES TO ARRANGE FOR A PRE-CONSTRUCTION MEETING.
2. LIMITS OF DISTURBANCE MUST BE FIELD MARKED PRIOR TO INSTALLATION OF SEDIMENT CONTROL DEVICES.
3. CLEAR AND GRUB ONLY THAT PORTION OF THE SITE NECESSARY TO INSTALL PHASE 1 EROSION AND SEDIMENT CONTROLS.
4. INSTALL ALL E & S CONTROL MEASURES AS SHOWN ON THE PHASE 1 AND PHASE 2 EROSION & SEDIMENT PLANS.
A. ACCESS FOR CONSTRUCTION SHALL BE FROM THE EXISTING DRIVEWAY ON NORTHEN SIDE AND HAVE PROVIDED AN ONSITE CONCRETE WASHOUT STRUCTURE (CWS), AS SHOWN. ACCESS CONSTRUCTION #1 ON SOUTH SITE SHALL BE FROM THE EXISTING ROAD, AS SHOWN. SEE DRAWINGS CS8001 AND CS8002 FOR EROSION AND SEDIMENT PLAN NOTES FOR LIMITED ACCESS TO LIMITS OF DISTURBANCE (LOD) VIA STABILIZED CONSTRUCTION ENTRANCES.
B. INSTALL SILT FENCE AND INLET PROTECTIONS, FILTER LOG, REMOVABLE PUMPING STATION, SUMP PIT, PORTABLE SEDIMENT TANK, FILTER BAG BEFORE
BEGINNING CONSTRUCTION OF THE SITE.
C. MAINTAIN AND ADJUST EROSION AND SEDIMENT CONTROL MEASURES AS NEEDED FOR PHASE 2 AS SHOWN ON THE PHASE 2 EROSION & SEDIMENT PLANS AS GRADING AND EARTHWORK OPERATIONS ARE ON-GOING. THE DISTURBED AREAS WITHIN THE LIMITS OF DISTURBANCE SHALL BE STABILIZED AS SOON
AS CONSTRUCTED TO PRECLUDE SEDIMENT FROM ENTERING THE STORM SYSTEM.
D. THE WORK SHOWN IN THE PLAN SHALL BE DONE USING THE METHOD OF 'SAME DAY STABILIZATION'. NO MORE LAND AREA (FOR LENGTH OF TRENCH, SWALE, CHANNEL, ETC.) SHALL BE DISTURBED THAN CAN BE STABILIZED BY THE END OF THE SAME WORKDAY. ALL DISTURBED AREAS THAT DO NOT DRAIN TO A SEDIMENT CONTROL DEVICE SHALL BE STABILIZED BY THE END OF SAME WORKDAY. NO DISTURBED AREA SHALL BE LEFT UNSTABILIZED OVERNIGHT UNLESS THE RINOFF IS DIRECTED TO AN MDE APPROVED SEDIMENT CONTROL DEVICE. FOR WORK ACTIVITIES IN PAVED AREAS, THE STONE BASE COURSE LAYER MUST BE PLACED BY THE END OF THE SAME DAY TO QUALIFY AS SAME DAY STABILIZATION.
E. ONCE ALL AREAS ARE FULLY STABILIZED AND WITH WSA INSPECTOR'S PERMISSION CONSTRUCTION SHALL COMMENCE. PRECLUDE ANY SEDIMENT LADEN RUNOFF FROM ESCAPING THE APPROVED LIMITS OF DISTURBANCE DURING AND AFTER CONSTRUCTION.