Goodwin Mechancial_partial set.pdf
PDF 2 MB Posted
- Solicitation number
- 87-07082026
- Issued by
- Cabarrus County, North Carolina
About this file
This file consists of HVAC piping floor plans and construction documents for Goodwin Hall at the North Carolina School of Science and Mathematics (NCSSM) Western Campus in Durham, North Carolina. The documents, prepared by Newcomb & Boyd consulting engineers and architectural firms including Duda|Paine Architects and Belk Architecture, depict the detailed routing and installation specifications for a Variable Refrigerant Flow (VRF) HVAC system across four levels of the building. The piping plans show refrigerant line routing between outdoor condensing units (VRF-A1 through VRF-A6), branch circuit controllers (BCC-A1 through BCC-A6), and fan-coil units (identified as VRF designations) throughout the building's occupied spaces. The drawings also indicate condensate drain routing, pipe sizes ranging from 0.75 inches to 1.25 inches in diameter, and include notes referencing wall fire ratings, elevator locations, and room designations across the four floors. The construction documents are dated April 17, 2020, with subsequent revisions and change order requests (CPR) issued between August 2020 and August 2021.
The technical specifications indicate that specific pipe quantities and sizes are to be determined by the HVAC manufacturer and installed in accordance with manufacturer recommendations. The documents include general notes specifying that wall-mounted fan-coil units should be installed on vertical soffit faces and that condensate drains should be routed to the nearest floor drain or mop sink, with cleanout locations clearly marked throughout the building. These construction documents serve as part of the bid set (SCO # 16-14368-02F) for the NCSSM-Morganton campus HVAC maintenance services contract, which includes preventative maintenance and repair services for multiple buildings on the campus.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
9.5 10 11 12
D
J
J.9
L
3.5
3.7
4 5 6 7 8 9
A
B
C
E
H
G
N
M
K
P
Q
R
F
5.6 6.5
ERU-A-1ERU-A-1
UH-A-1
UH-A-2
FTR-A-3
FTR-A-1
FTR-A-2
FTR-A-4
5.1 10.59.98.9
VRF-A4
VRF-A6
VRF-A3
VRF-A5
ERU-A-1 CU
VRF-A1-3
VRF-A1-1
VRF-A1-2
VRF-A1-4
VRF-A1-5
DSS-A1-1
VRF-A1-6
VRF-A2-5
VRF-A1-7
VRF-A2-1
VRF-A2-3
VRF-A2-7
VRF-A2-6
VRF-A2-8
DSS-A1-3
VRF-A2-2 VRF-A2-4
VRF-A2-9
BCC-A1
BCC-A2
ERU-A-2 CU
ERU-A-2
T
VRF-A2-10
T
T
T
T T
T
T
T
T
T
T
T
T
T
T
T
T
T
0.75" D 0.75" D
1" D
ROUTE 1" CONDENSATE DRAIN DOWN
TIGHT TO WALL TO MOP SINK
ROUTE 2" CONDENSATE
TO NEAREST FLOOR
DRAIN
REFRIGERANT
PIPING (TYP.)
REFRIGERANT
PIPING (TYP.)
REFRIGERANT PIPING UP TO BRANCH
CIRCUIT CONTROLLERS
REFRIGERANT PIPING
UP TO BRANCH CIRCUIT
CONTROLLERS
REFRIGERANT PIPING
FROM BCC-A2
CONDENSING UNIT UP
UH-A-3
1" D
FUTURE OFFICE
FUTURE FACILITIES
MAIN MECHANICAL
ROOM
JAN
UTILITY ENTRANCE
ROOM
MEN
118B
CORRIDOR
CHECK-IN
TECHNOLOGY SYSTEMS
SUITE
1203A
FUTURE FACILITIES
FUTURE FACILITIES
STORAGE
1003A
CORRIDOR
1200C
MAIN ELEC.
WOMEN
118A
ADMINISTRATIVE
SUPPORT SUITE
STAIR 1
1200B
ST1-1
VESTIBULE
1200A
ACADEMIC PROGRAMS
SUPPORT SUITE
FUTURE OFFICE
FUTURE OFFICE
FUTURE STOR/MECH
FUTURE CORRIDOR
VESTIBULE
1100A
STAIR 2
1100B
ST2-1
SECURITY
STORAGE
1002A
CORRIDOR
ELEV. E4
UNISEX
MAIN COMM.
UNISEX
119A
WOMEN
VESTIBULE/HALL
144A
0.75" D
0.75" D
0.75" D
1" D 0.75" D
0.75" D
0.75" D
DSS-A1-2
DSS-A1-1 CU
DSS-A1-2 CU
DSS-A3-1 CU
DSS-A2-1 CU
REFRIGERANT PIPING UP TO
DSS-A2-1 AND DSS-A3-1
ROUTE 0.75" D TO
NEAREST FLOOR
DRAIN
DSS-A1-3 CU
GENERATOR AND GENERATOR
CLEARANCE - REFER TO
ELECTRICAL DRAWINGS
DROP REFRIGERANT PIPING IN THE
STORAGE ROOM AND ROUTE THROUGH
EXTERIOR WALL LOW. PIPING SHALL EXIT
BUILDING IN NEAT AND ORDERLY FASHION.
VRF-A1-8
T
CAMPUS SAFTEY SUITE
1203B
MAILROOM
1104A
FUTURE OFFICE
MAILROOM
1104A
0.75" D
T
VRF-A2-14
Wall Rating Legend
1-Hour Fire Barrier
2-Hour Fire Barrier
Unrated Walls
Smoke Partition
3-Hour Fire Barrier
2-Hour Smoke Barrier
1-Hour Smoke Barrier
Newcomb&Boyd
CONSULTANTS AND ENGINEERS
ISSUE DATE:
PROJECT NUMBER:
OWNER
NCSSM
1219 Broad St, Durham, NC 27705
ARCHITECT
Duda|Paine Architects, PA
333 Liggett Street
Durham, NC 27701
ADAPTIVE RE-USE ARCHITECT
Belk Architecture
735 9th Street
Durham, NC 27705
LANDSCAPE ARCHITECT
Stewart, Inc
421 Fayetteville St. Suite 400
Raleigh, NC 27601
CIVIL ENGINEER
Stewart, Inc
421 Fayetteville St. Suite 400
Raleigh, NC 27601
STRUCTURAL ENGINEER
Bennett & Pless
1309 Amble Drive
Charlotte, NC 28206
MEP&FP ENGINEER
Newcomb & Boyd
303 Peachtree Center Ave., NE
Suite 525
Atlanta, GA 30303
FOOD SERVICE DESIGN
Food Design Associates
615 South College Street
9th Floor
Charlotte, NC 28202
COST ESTIMATOR
RM Rutherford & Associates Inc
3328 Mill Pond Road
Charlotte, NC 28226
This document is the product and exclusive property of Duda|Paine
Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of
Duda|Paine Architects, PA.
© Copyright 2019 Duda|Paine Architects, PA
Copyright © 2019 Consulting Engineering Group T 404 730-8400 Firm License No. F-03112 Contact: Richard O. Dozier
N&B PROJECT:17N0548
/2 /2
:5 :0
P
M
MA200
HVAC PIPING
LEVEL 1 FLOOR
PLAN
04/17/20 21611
Construction Documents Bid Set
SCO # 16-14368-02F
N C
S S M
W e st e rn
C a m p u s
B u ild in g A
G o o d w in H a ll
1/8" = 1'-0"MA200
1 HVAC PIPING LEVEL 1 FLOOR PLAN
ROUTE 1" CONDENSATE
TO NEAREST FLOOR DRAIN
1" CONDENSATE
DOWN FROM
SECOND FLOOR
KEY NOTES THIS SHEET:
REFRIGERANT PIPING TO ENERGY RECOVERY UNIT
COOLING COIL AND HOT GAS REHEAT COIL. INSTALL
PER MANUFACTURER'S INSTRUCTIONS.
CONDENSATE DRAIN CLEANOUT LOCATION.
GENERAL NOTES THIS SHEET:
1. THIS DRAWING DEPICTS THE GENERAL ROUTING OF PIPING
BETWEEN VRF OUTDOOR UNITS AND BRANCH SELECTORS,
AND BETWEEN BRANCH SELECTORS AND FAN-COIL UNITS.
QUANTITIES AND SIZES OF PIPES REQUIRED SHALL BE
DETERMINED BY THE MANUFACTURER AND INSTALLED IN
ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS.
N
A
B
C
E
D
F
KEY PLAN
MARK DATE DESCRIPTION
45 08/07/2020 CPR-039
51 09/22/2020 RFI-449
54 10/28/2020 CPR-048
90 06/23/2021 CPR-083
100 08/26/2021 CPR-090
DocuSign Envelope ID: 13633A38-FB58-4412-890A-A05967C6B9B4
08/25/2021
J
J.9
L
3.5
3.7
4 5 6 7 8 9
A
B
C
E
H
G
N
M
K
P
Q
R
F
5.6 6.5
MA601
5.1 10.59.98.9
VRF-A3-3
VRF-A3-1
VRF-A3-5
VRF-A3-10
VRF-A3-11 VRF-A4-2
VRF-A4-9VRF-A4-6
VRF-A4-3
VRF-A4-1VRF-A3-12
VRF-A2-11
VRF-A2-12
VRF-A3-13
VRF-A3-2
VRF-A3-4
VRF-A3-6
VRF-A3-7
DSS-A2-1
VRF-A4-4
VRF-A4-7
VRF-A4-10
VRF-A3-8
VRF-A3-9
VRF-A2-13
VRF-A4-5
BCC-A3 REFRIGERANT PIPING
FROM VRF-A3
CONDENSING UNIT DN
REFRIGERANT
PIPING FROM VRF-
A5 CONDENSING
UNIT UP & DN
REFRIGERANT
PIPING (TYP.)
REFRIGERANT
PIPING (TYP.)
REFRIGERANT
PIPING (TYP.)
REFRIGERANT
PIPING (TYP.)
REFRIGERANT PIPING
FROM VRF-A4
CONDENSING UNIT DN
REFRIGERANT
PIPING FROM VRF-
A6 CONDENSING
UNIT UP & DN
REFRIGERANT PIPING
FROM BCC-A2 DN
VRF-A4-8
BCC-A4
T
T
T
T
T
T
T
T
T
T T
T
T
T
T
T
T
T
T
T
T T T T T
T
T
1" DN
1" D
0.75" D
1" D
0.75" D
1" D DN
0.75" D
0.75" D
1" D
0.75" D
1" D
0.75" D
1 1 1
0.75" D 0.75" D 0.75" D
1" D
1.25" D
CLASSROOM
CORRIDOR
COMMONS
FACULTY HUB
CLASSROOM
OUTREACH SUITE
GROUP STUDY
223B
VESTIBULE
2200A
STAIR 1
2200B
ST1-2
GROUP STUDY (M)
STAIR 2
2100B
ST2-2
VESTIBULE
2100A
ENROLLMENT SERVICES
SUITE
CLASSROOM
CLASSROOM
CONF. ROOM
ELEV. E4
CONNECTOR
2000A
ADMISSIONS SUITE
CORRIDOR
STORAGE
MEN
216B
WOMEN
216A
ELEC.
214A
DEPARTMENT CHAIR
SUITE
CORRIDOR
HSKPG
COMM.
MTG
FACULTY BREAK
2004A
FUTURE EXTERIOR
TERRACE
MTG
MTG
GROUP STUDY
223C
ROUTE 1.25"
CONDENSATE
DRAIN DOWN
TIGHT TO WALL
TO MOP SINK
1" D UP
0.75" D
REFRIGERANT PIPING
DOWN TO DSS-A2-1 CU
0.75" D
Wall Rating Legend
1-Hour Fire Barrier
2-Hour Fire Barrier
Unrated Walls
Smoke Partition
3-Hour Fire Barrier
2-Hour Smoke Barrier
1-Hour Smoke Barrier
Newcomb&Boyd
CONSULTANTS AND ENGINEERS
ISSUE DATE:
PROJECT NUMBER:
OWNER
NCSSM
1219 Broad St, Durham, NC 27705
ARCHITECT
Duda|Paine Architects, PA
333 Liggett Street
Durham, NC 27701
ADAPTIVE RE-USE ARCHITECT
Belk Architecture
735 9th Street
Durham, NC 27705
LANDSCAPE ARCHITECT
Stewart, Inc
421 Fayetteville St. Suite 400
Raleigh, NC 27601
CIVIL ENGINEER
Stewart, Inc
421 Fayetteville St. Suite 400
Raleigh, NC 27601
STRUCTURAL ENGINEER
Bennett & Pless
1309 Amble Drive
Charlotte, NC 28206
MEP&FP ENGINEER
Newcomb & Boyd
303 Peachtree Center Ave., NE
Suite 525
Atlanta, GA 30303
FOOD SERVICE DESIGN
Food Design Associates
615 South College Street
9th Floor
Charlotte, NC 28202
COST ESTIMATOR
RM Rutherford & Associates Inc
3328 Mill Pond Road
Charlotte, NC 28226
This document is the product and exclusive property of Duda|Paine
Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of
Duda|Paine Architects, PA.
© Copyright 2019 Duda|Paine Architects, PA
Copyright © 2019 Consulting Engineering Group T 404 730-8400 Firm License No. F-03112 Contact: Richard O. Dozier
N&B PROJECT:17N0547
/2 /2
:1 :2
P
M
MA201
HVAC PIPING
LEVEL 2 FLOOR
PLAN
04/17/20 21611
Construction Documents Bid Set
SCO # 16-14368-02F
N C
S S M
W e st e rn
C a m p u s
B u ild in g A
G o o d w in H a ll
1/8" = 1'-0"MA201
1 HVAC PIPING LEVEL 2 FLOOR PLAN
KEY NOTES THIS SHEET:
INSTALL WALL-MOUNTED FAN-COIL UNIT ON
VERTICAL FACE OF SOFFIT.
CONDENSATE DRAIN CLEANOUT LOCATION.
GENERAL NOTES THIS SHEET:
1. THIS DRAWING DEPICTS THE GENERAL ROUTING OF PIPING
BETWEEN VRF OUTDOOR UNITS AND BRANCH SELECTORS,
AND BETWEEN BRANCH SELECTORS AND FAN-COIL UNITS.
QUANTITIES AND SIZES OF PIPES REQUIRED SHALL BE
DETERMINED BY THE MANUFACTURER AND INSTALLED IN
ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS.
N
A
B
C
E
D
F
KEY PLAN
MARK DATE DESCRIPTION
54 10/28/2020 CPR-048
90 06/23/2021 CPR-083
99 07/26/2021 CPR-089
07/26/2021
DocuSign Envelope ID: 5EF9F5A3-BA8B-4559-A77D-585172ABBD30
J
J.9
L
3.5
3.7
4 5 6 7 8 9
A
B
C
E
H
G
N
M
K
P
Q
R
F
5.6 6.5
5.1 10.59.98.9
VRF-A5-2 VRF-A5-4
VRF-A5-9
VRF-A5-10
VRF-A5-15 VRF-A6-3
VRF-A6-9
VRF-A6-11
VRF-A5-5
VRF-A5-6VRF-A5-3
DSS-A3-1
VRF-A5-8
VRF-A5-7
VRF-A5-11
VRF-A6-5
VRF-A6-10
VRF-A6-8
VRF-A6-4
VRF-A5-1
VRF-A5-14
VRF-A6-2
VRF-A6-7
VRF-A5-12 VRF-A6-1
BCC-A5
REFRIGERANT PIPING
FROM BCC-A5
CONDENSING UNIT UP
REFRIGERANT
PIPING FROM VRF-
A5 CONDENSING
UNIT DN
REFRIGERANT
PIPING (TYP.)
REFRIGERANT
PIPING (TYP.)
REFRIGERANT
PIPING (TYP.)
REFRIGERANT
PIPING (TYP.)
VRF-A5-13
0.75" D1" D
0.75" D
0.75" D
1" D DN
0.75" D
1" D
1" D 1.25" D
ROUTE 1.25" CONDENSATE
DOWN TIGHT TO WALL AND
TERMINATE IN MOP SINK
1" D
0.75" D
1" D
0.75" D
T
T
T T
T
T
T
T
T
T
T
T
T T
T
T
T
T
T T T T
T
1" D UP
VRF-A6-6
1 1
ACADEMIC PROGRAMS
SUITE
MTG
DISTANCE ED. &
EXTENDED PROGRAMS
SUITE
FINANCE & BUDGET SUITE
ELEC
CLASSROOM
CLASSROOM
CONF. ROOM
CLASSROOM
STUDY LOUNGE
CORRIDOR
STAIR 1
3200B
ST1-3
STAIR 2
3100B
ST2-3
TERRACE
3000A 311A
ELEV. E4
STUDENT LIFE SUITE
VESTIBULE
3200A
VESTIBULE
3100A
CONF ROOM
BREAK ROOM
CORRIDOR
WOMEN
318A
HSKPG
321A
COMM.
316A
MEN
318B
COPY ROOM
3004A 313A
3RD FL RECEPTION
NCSSM-MORGANTON
LEADERSHIP SUITE
MTG
MTG
STORAGE
317A
COPY ROOM
313B
0.75" D
1" D DN
REFRIGERANT
PIPING UP TO BCC-A6
REFRIGERANT
PIPING UP TO BCC-A6
REFRIGERANT PIPING
DOWN TO DSS-A3-1 CU
0.75" D
ASST. DIR. HR
3111B
HR TECH.
3111A
T
0.75" D
REFRIGERANT
PIPING (TYP.)
VRF-A6-12
T
Wall Rating Legend
1-Hour Fire Barrier
2-Hour Fire Barrier
Unrated Walls
Smoke Partition
3-Hour Fire Barrier
2-Hour Smoke Barrier
1-Hour Smoke Barrier
Newcomb&Boyd
CONSULTANTS AND ENGINEERS
ISSUE DATE:
PROJECT NUMBER:
OWNER
NCSSM
1219 Broad St, Durham, NC 27705
ARCHITECT
Duda|Paine Architects, PA
333 Liggett Street
Durham, NC 27701
ADAPTIVE RE-USE ARCHITECT
Belk Architecture
735 9th Street
Durham, NC 27705
LANDSCAPE ARCHITECT
Stewart, Inc
421 Fayetteville St. Suite 400
Raleigh, NC 27601
CIVIL ENGINEER
Stewart, Inc
421 Fayetteville St. Suite 400
Raleigh, NC 27601
STRUCTURAL ENGINEER
Bennett & Pless
1309 Amble Drive
Charlotte, NC 28206
MEP&FP ENGINEER
Newcomb & Boyd
303 Peachtree Center Ave., NE
Suite 525
Atlanta, GA 30303
FOOD SERVICE DESIGN
Food Design Associates
615 South College Street
9th Floor
Charlotte, NC 28202
COST ESTIMATOR
RM Rutherford & Associates Inc
3328 Mill Pond Road
Charlotte, NC 28226
This document is the product and exclusive property of Duda|Paine
Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of
Duda|Paine Architects, PA.
© Copyright 2019 Duda|Paine Architects, PA
Copyright © 2019 Consulting Engineering Group T 404 730-8400 Firm License No. F-03112 Contact: Richard O. Dozier
N&B PROJECT:17N0547
/2 /2
:1 :3
P
M
MA202
HVAC PIPING
LEVEL 3 FLOOR
PLAN
04/17/20 21611
Construction Documents Bid Set
SCO # 16-14368-02F
N C
S S M
W e st e rn
C a m p u s
B u ild in g A
G o o d w in H a ll
1/8" = 1'-0"MA202
1 HVAC PIPING LEVEL 3 FLOOR PLAN
KEY NOTES THIS SHEET:
INSTALL WALL-MOUNTED FAN-COIL UNIT ON
VERTICAL FACE OF SOFFIT.
CONDENSATE DRAIN CLEANOUT LOCATION.
GENERAL NOTES THIS SHEET:
1. THIS DRAWING DEPICTS THE GENERAL ROUTING OF PIPING
BETWEEN VRF OUTDOOR UNITS AND BRANCH SELECTORS,
AND BETWEEN BRANCH SELECTORS AND FAN-COIL UNITS.
QUANTITIES AND SIZES OF PIPES REQUIRED SHALL BE
DETERMINED BY THE MANUFACTURER AND INSTALLED IN
ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS.
N
A
B
C
E
D
F
KEY PLAN
MARK DATE DESCRIPTION
54 10/28/2020 CPR-048
62 04/27/2021 CPR-056 Rev
90 06/23/2021 CPR-083
99 07/26/2021 CPR-089
07/26/2021
DocuSign Envelope ID: 5EF9F5A3-BA8B-4559-A77D-585172ABBD30
J
J.9
L
3.5
3.7
4 5 6 7 8 9
A
B
C
E
H
G
N
M
K
P
Q
R
F
5.6 6.5
MA401
UH-A-4
UH-A-5
UH-A-6
UH-A-7
5.1 10.59.98.9
VRF-A5-17
REFRIGERANT PIPING
FROM BCC-A5 DN
REFRIGERANT PIPING
T
T
T
T
T
T
1" D
1" CONDENSATE
DN
VRF-A5-16
UNOCCUPIED ROOF
CAVITY
ELEVATOR VEST.
ELEV. E4
MULTIPURPOSE SPACE
UNOCCUPIED ROOF
CAVITY
BALCONY
PREP
STOR.
BCC-A6
REFRIGERANT PIPING
FROM VRF-A6
CONDENSING UNIT DN
REFRIGERANT
PIPING DN TO
FAN-COIL UNITS
REFRIGERANT
PIPING DN TO
FAN-COIL UNITS
Wall Rating Legend
1-Hour Fire Barrier
2-Hour Fire Barrier
Unrated Walls
Smoke Partition
3-Hour Fire Barrier
2-Hour Smoke Barrier
1-Hour Smoke Barrier
Newcomb&Boyd
CONSULTANTS AND ENGINEERS
ISSUE DATE:
PROJECT NUMBER:
OWNER
NCSSM
1219 Broad St, Durham, NC 27705
ARCHITECT
Duda|Paine Architects, PA
333 Liggett Street
Durham, NC 27701
ADAPTIVE RE-USE ARCHITECT
Belk Architecture
735 9th Street
Durham, NC 27705
LANDSCAPE ARCHITECT
Stewart, Inc
421 Fayetteville St. Suite 400
Raleigh, NC 27601
CIVIL ENGINEER
Stewart, Inc
421 Fayetteville St. Suite 400
Raleigh, NC 27601
STRUCTURAL ENGINEER
Bennett & Pless
1309 Amble Drive
Charlotte, NC 28206
MEP&FP ENGINEER
Newcomb & Boyd
303 Peachtree Center Ave., NE
Suite 525
Atlanta, GA 30303
FOOD SERVICE DESIGN
Food Design Associates
615 South College Street
9th Floor
Charlotte, NC 28202
COST ESTIMATOR
RM Rutherford & Associates Inc
3328 Mill Pond Road
Charlotte, NC 28226
This document is the product and exclusive property of Duda|Paine
Architects, PA. Neither the document nor the information it contains may be copied, disclosed to others or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of
Duda|Paine Architects, PA.
© Copyright 2019 Duda|Paine Architects, PA
Copyright © 2019 Consulting Engineering Group T 404 730-8400 Firm License No. F-03112 Contact: Richard O. Dozier
N&B PROJECT:17N0541
/2
/2
:4 :0
P
M
MA203
HVAC PIPING
LEVEL 4 FLOOR
PLAN
04/17/20 21611
Construction Documents Bid Set
SCO # 16-14368-02F
N C
S S M
W e st e rn
C a m p u s
B u ild in g A
G o o d w in H a ll
1/8" = 1'-0"MA203
1 HVAC PIPING LEVEL 4 FLOOR PLAN
N
A
B
C
E
D
F
KEY PLAN
MARK DATE DESCRIPTION
54 10/28/2020 CPR-048
62 12/21/2020 CPR-056
DocuSign Envelope ID: 4E9660B1-F232-4FE4-A2E0-EEAAD261FB6F
12/22/2020
File details come from the government source that posted it. Updated .