FI23-013-VA-Walla-Walla-Bldg-78-FA_Record.pdf
PDF 5 MB Posted
- Attached to
- H212 Fire Alarm Inspections, Testing, Maintenance & Repairs - Walla Walla VA - Dept of Veterans Affairs
- Solicitation number
- 36C26025Q0599
About this file
These are record drawings for a fire alarm system replacement project at the VA Walla Walla Medical Center, Building 78, located at 77 Wainwright Drive in Walla Walla, Washington. The project involves a comprehensive fire alarm system upgrade, including replacing existing copper cabling with new fiber optic infrastructure, installing new fire alarm control panels with campus-wide network monitoring, and replacing all existing fire alarm devices such as pull stations, detectors, relay modules, and associated conduit and cabling.
The new Notifier fire alarm system will include voice evacuation notification appliances throughout the building, smoke and heat detectors installed per code requirements, manual pull stations at building exits, and an annunciator with campus-wide monitoring located in the main office basement. The system will provide monitoring of the fire sprinkler system, with tamper switches generating supervisory signals. The project covers multiple building levels including basement, sub-basement, first floor, and upper level, with devices strategically placed to ensure comprehensive fire detection and notification. The system will integrate with elevator controls, security systems, and central monitoring, and is designed to comply with 2018 IBC, IFC, NFPA 101, and other relevant safety standards.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Number of Sheets:
By
Installing Fire Alarm System Contractor:
Date
Drawn By:
Drawn Date:
Scale:
Drawing No.
Revisions Description
Authority Having Jurisdiction:
Project Contacts
DHL
04/29/2024
VA
W al la
W al la
B ui ld in g
W ai nw rig ht
D riv e W al la
W al la , W
A
Li fe
S af et y
(F ire
A la rm S ys te m ) D ra w in gs
COPYRIGHT NOTICE
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN
CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF
VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED
OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF
VULCAN FIRE
Reviewed by:
ENGINEERED SYSTEM DISTRIBUTION
by Honeywell
TM
Vulcan Project #: FI23-013
U .S
.D ep ar tm en t o f V et er an s A ffa irs
Fi re
A la rm S ys te m R ep la ce m en t -
P ha se B
Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362
(509) 524-4603
Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814
(208) 277-0171
GC
L ice ns e:
V
UL
CA
F*
0M
El ec
L ice ns e:
V
UL
CA
F*
W
EB
SI
TE
: w w w
.v ul ca nf ire us
.c om
PH
ON
E
(2
) 2
-0
Ea st H az el
A ve nu e, S ui te
1, C oe ur d 'A le ne
, I da ho
Record Drawings (04/23/2025)
N/A
FA-0.0
Site Plan
General Notes:
Drawing Notes:
Fire Alarm Control Panel Terminations:
Scope of Work:
All wiring runs shown on the fire alarm shop drawings are conceptual only. They do not and are not intended to be actual wire runs or conduit runs. Device interconnect is intended to show only sequence of device connections and type of wire.
Please review both the floor plans and the riser diagram drawings to resolve any conflicts or questions that may come up. If the drawings do not answer your questions, please call Vulcan Fire for help to answer your questions.
Electrical Contractor is advised not to complete terminations at the Fire Alarm Control Panel. Terminations will be completed by a qualified Vulcan Fire Technician.
Code Analysis:
Edition of Codes:
Number of Stories:
Edition of Standards:
Occupancy Type: B, Business (Clinic, Exam, Offices) S-1 Storage (Storage Closets) A-1 Assembly (Auditorium)
2018 IBC, IFC, IMC
2018 NFPA 101
City of Walla Walla Amendments 2009 ANSI 117.1 Guidelines for Accessible & Useable
Yes, Fully Fire Sprinklered
1 w/ Unoccupied Basement
Visual Notification: Public Mode
Wire runs are indicated by AlphaNumeric designations.
power run of "2#__ " cable. A designation of "P3" would indicate another individual run of "2#__ " cable.
"2#__Twisted AND a run of 2#__ " cable.
A designation of "A,P2", would refer to a run of
The wire Gauge of any wire run is determined by the
A designation of "P2", would refer to a individual pair, 2#__ Twisted" cable.
A designation of "2A", would refer to a run of "2 length of the wire run and the power load on that run.
A typical wire run designated as "A", would refer to a single run of "2 #__ Twisted" cable.
For example:
A,P2
P2,P3
A
2A
Wire Chart:
Audible Notification: Voice Evac - Temporal 3 Pattern / Synchronized
Type of FA System: New Fire Alarm Addressable System
Index of Drawings Drawing Name
Drawing Number
Cover SheetCover SheetFA-0.0 FA-1.1 Basement - Fire Alarm Plan /
Sub-Basement - Fire Alarm Plan / First Floor - Fire Alarm Plan / Second Floor- Fire Alarm Plan
Temporal Pattern Notification Device Numbering:
(IE: HORN/STROBE)
AUDIBLE/VISUAL DEVICE
(IE: STROBE ONLY)
AUDIBLE DEVICE
(IE: HORN ONLY)
WITH THE REQUIREMENTS FOR VISUAL DEVICES.
1. ADA ACCESSIBILITY GUIDELINES HAVE ACCEPTED NFPA 72 GUIDELINES AS "EQUIVALENT FACILITATION".
3. MEASUREMENT IS TO THE BOTTOM OF THE DEVICE.
2. NFPA 72 STATES THAT COMBINATION AUDIBLE/VISUAL DEVICES SHALL BE MOUNTED IN ACCORDANCE
NOTES:
AFF = ABOVE FINISHED FLOOR0" (FLOOR)
NFPA 72
A
90" A.F.F.
A/V
96" A.F.F.
80" A.F.F.
NFPA 72
MAX.
MIN.
V
VISUAL DEVICE
CEILING
6" BELOW
CEILING
Example of Proper Mounting for Audible/Visual Devices:
Example of Junction Box Detail (FA):
If Applicable (Use for eample only)
Sheet Number
Walla Walla, WA 99362
U.S. Department Of Veterans Affairs VA Medical Center
77 Wainwright Drive
Owner
Fire Protection System:
Square Footage:
FA System Required: Code-Required
Project Manager: Dave Clem
GDM of Oregon 1584 McNeil Street, Suite 200
DuPont, WA 98327
Architect / Engineer
3,264 GSF
Protected Premises Fire Alarm Systems (Wiring):
Mounted Candela Rating:
S150 = 150 Candela S177 = 177 Candela S185 = 185 Candela
S135 = 135 Candela
S115 = 115 Candela S110 = 110 Candela S95 = 95 Candela S75 = 75 Candela S30 = 30 Candela S15 = 15 Candela
Ceiling S15C S15
Wattage Speaker 1W Tap
Guard WireWG WeatherproofWP
VOICE CIRCUIT
V 2
2S
POWER SUPPLY NUMBER
STROBE CIRCUIT
CIRCUIT NUMBER
AMPLIFIER NUMBER
CIRCUIT NUMBER
("T" Tap)
Class B
Class B
P
F P
VS VSAIM
Class B
IDC - Initiating Device Circuit Manual Pull Stations, Fire Sprinkler System, Etc.
NAC - Notification Appliance Circuit Horns, Bells, Strobes, Etc.
SLC - Signaling Line Circuit Intelligent (Addressable) Devices
Only in J-Box (per Owner)
FS
S
Where used, End-Of-Line Resistors shall be labeled "EOL" on the Device (per Owner)
Building 78 77 Wainwright Drive, Walla Walla, WA 99362
Fire Alarm System Replacement
The scope of work for this project is to replace the existing campus fire alarm system with a new fire alarm system throughout. The existing copper cabling backbone infrastructure will be replaced with new fiber optic cabling. Each building will be provided with new fire alarm control panels connected to the campus network. A new campus wide computer monitoring and control system will be provided in Building 78.
Existing fire alarm devices such as pull stations, detectors, relay modules, monitor modules, flow and tamper switch interfaces, and associated conduit, boxes and cabling shall be demolished and replaced with new devices.
Building 78 Fire Alarm System:
The new Notifier fire alarm system in Building 78 will be replacing the existing fire alarm system. Voice evacuation notification appliances will be installed throughout the entire building, which will alert the occupants in the event of a fire. The FACP will provide monitoring of the fire sprinkler system. Smoke and Heat Detectors will be installed where required per codes. New manual pull station will be installed at building exits. An annunciator with campus wide monitoring and control is provided in the Main Office in the Basement.
The fire sprinkler tamper switches will cause a supervisory signal when activated. These devices will report as a supervisory signal.
The fire alarm system shall be monitored through a central monitoring company of the owners choosing prior to the final inspection.
N
All intelligent and or addressable Fire Alarm Devices must be placed in protected areas with ambient temperature ranging from 32° to 120°. Weatherproof Fire Alarm Devices have temperature rating from -40° to 151° in wet or dry applications.
Do not place smoke detectors within 3 feet of air supply registers and diffusers.
All intelligent devices shall be interconnected as shown on the riser on-line diagram. Each intelligent device is designed with an address. T-Tapping is permitted on SLC Loop (Class "B") only.
Wire runs show interconnected of fire alarm devices only. Wiring does not represent conduit runs.
Electrical Contractor is responsible for proper connection of equipment provided by others.
(RL) Indicates Existing Device to be relocated to new location.
(R) Indicates Device to be removed and returned to Owner.
(E) Indicates Device existing to remain (shown in gray scale).
(N) Indicates New Device.
(RR) Indicates Remove Existing Device and replace with new Device. Return any removed equipment to Owner.
Typical Device Mounting Height:
NFPA 2016
Wall Mounted AUDIBLE device.
Top of Individual Device
MAX
4'-0"
"ADA"
(48")
Top of Device of the Same Lens
Top of Unit
Top of Cabinet
To Handle of Device Per NFPA 72 from (AFF) Above All heights measured
NOT TO SCALE
Finished Floor
BOTTOM
OF
6'-0"
80" TO
MIN* (72")
LENS
See Note #5
7'-0"
TO TOP
OF
Approx.96"
MAX*
(84")LENS
(6")
THAN
BELOW
CEILING
(90")
AND
LESS
THAN
NOT
LESS
NOT
(64") 5'-4" or 80" MIN. to Bottom A/V or Visual Only Devices
MAX 96" to Top of Lens for all
#1) HEIGHTS SHOWN ARE LISTED IN NFPA STANDARDS 2016.
#2) MOUNTING HEIGHTS LISTED IN SPECIFICATIONS OR SHOWN ON THE
ARCHITECTURAL ELEVATIONS SHALL GOVERN. ANY DISCREPANCY SHALL BE
BROUGHT TO THE ATTENTION OF THE AHJ AND THE ENGINEER OF RECORD.
#3) WALL MOUNTED ADA STROBES & HORN/STROBES ARE TO BE PLACED
A MINIMUM OF 80" ABOVE FINISHED FLOOR MEASURED AT THE BOTTOM OF
THE LENS OR 6" BELOW THE CEILING TO THE TOP OF THE LENS,
WHICHEVER IS LOWEST. THE MAXIMUM HEIGHT MEASURED AT THE TOP OF
THE LENS SHALL NOT EXCEED 96".
#4) IN SLEEPING ROOMS A STROBE MOUNTED LESS THAN 24" FROM THE
CEILING SHALL BE AT LEAST 177CD. STROBES MOUNTED 24" OR BELOW
SHALL BE AT LEAST 110 CD. A STROBE SHALL BE MOUNTED WITHIN 16FT
OF THE PILLOW.
#5) REMOTE LIGHTS, TEST STATIONS AND MODULES SHOULD BE MOUNTED
SO AS TO BE ACCESSIBLE, YET ABOVE EASY REACH TO PREVENT
VANDALISM.
#6) CEILING MOUNT VISIBLE DEVICES SHALL BE SPACED ACCORDING TO
2016 NFPA 72.
FSA
FACFACP RPS
AIM AOM
F
RL
S15H15 15MC15
RT
J DM
MAP FTR
C
AOM
R
S
(48") 4'-0"
*MAX
(42") 3'-6"
*MIN
U.S. Department of Veterans Affairs
VA WALLA WALLA - FIRE LIFE SAFETY - PHASE B Fire Alarm Systems Interconnect Drawings
X
X X
X X
X
X
X
X
XX X
X
X
X
X
X
X
STATE NURSING HOME
STATE NURSING HOME
STATE NURSING HOME
STATE NURSING HOME
N U
R
SIN
G H
O M
E
FU
TU
R E
BL
D
G
7 49 48
66T-7
77T-1
T-2
756968
116119
121126125124
109CM
147 146
W
SITE
78Setting Initiating Device Addresses:
D:L1: 501
ONESTENS
7 8 9
00 15
D = Detector M = Monitor
Device AddressData Loop Number
DIALS ARE
LOCATED ON THE
BACK OF EACH
DEVICE
N1:
Node Number
2016 NFPA 72, 2020 NFPA 70 (NEC), VA Fire Protection Manual
FA-2.1 Riser Diagram / Details / Load Calculations / Speaker Calculations / Fire Alarm Matrix
MAP
BATT
S P
FACP
EVAC
F
AIM
S15C
VS
WF
SS
FARC
Indicates Circuit Continuation Indicates Home Run to FACP
PS
PS LA
WF
S30C
S75C
FATC
F135°
AOM
R
R
WP F
15C
S15
S75
S15
WP
NCA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text PRV Vault
AutoCAD SHX Text F/A
AutoCAD SHX Text 8"
AutoCAD SHX Text Caps
AutoCAD SHX Text Tank
AutoCAD SHX Text Fuel
AutoCAD SHX Text F/A
AutoCAD SHX Text Valves
AutoCAD SHX Text
PRV
AutoCAD SHX Text F/A
General Note:
* All addressable devices require SLC Loop (A-wire) from the FACP to operate. For help, please refer to riser diagram for reference.
* Do not route conduit into the bottom of any fire alarm system component cabinets.
* Tap all speakers at 1/2 watt - 25 volts unless otherwise indicated at individual device.
* Contractor may reuse existing pathways where available. Verify with system designer prior to adding additional devices or extending circuits to ensure voltage drop calculations are within acceptable limits.
1) Section of NFPA 72, National Fire Alarm Code requires units to be provided with smoke detection in areas that are not continuously occupied.
2) Provide Dedicated 120VAC circuit to the FACP label the Dedicated circuit breaker "Fire Alarm." In red with lockout. Location of breaker shall be noted at FACP.
3) Fiber Network routing to be field coordinated.
4) Detector is to activate Elevator Recall Functions.
5) Detector is to activate Elevator Shunt Trip. Mount within 24" of Sprinkler
Head.
6) Visual Notification omitted in areas without existing devices or ADA requirements to comply with VA Fire Protection Manual Section 7.3.F.l.4.
Field verify single person offices with hearing-impaired occupants.
Flag Notes: (Some flag notes may not appear on every sheet)
Addressing Legend:
D = Detector M = Module
Module/Device Number M01L01
Loop Number N01Node Number
Dedicated
120VAC
SS
FARC
MAP
EP
To Bldg. Devices (SLC Loop) A
CPU2-640
HS-NCM-MF
NCA-2
DVC / CMIC-1
DAA2-7525 FACP
Spkr Crkts V0-1, V0-2, V0-3, V0-4BATT
NAC Crkts S0-1, S0-2, S0-3, S0-4, To Fiber Network Patch Panel2F
Components located inside of
FACP
EVAC
OFFICE
B104
OFFICE
B103
LOCKER
ROOM
B105 KITCHEN
B106
HVAC
VAULT
B107
B101A
IT/COMM
B102
OFFICE
101D
MAIN
OFFICE
B101 OFFICE
B101C
BREAK
B101BCB1-1
RESTROOM
B110STORAGE
B108
CB1-1
VAULT/
EMER/GEN
B111
S15 S0-2
S15 S0-2
S15 S0-2
STORAGE
S75C S0-2 V0-2
CELL
B101E
15C
S15C
S0-2 V0-2
F
NCA
S P
S30C
S0-2 V0-2
S15C
S0-2 V0-2
S15C S0-2 V0-2S15C
S0-2 V0-2
S75C
S0-2 V0-2
To
FACP
2AD,AP
8'-8" AFF
7'-9" AFF
8'-8" AFF
7'-11" AFF
8'-8" AFF 8'-2" AFF
8'-3" AFF
8'-5" AFF
7'-3" AFF
9'-8" AFF
7'-11" AFF
7'-10" AFF
7'-10" AFF
8'-3" AFF
8'-1" AFF
N34:L1:D010
N34:L1:M005
N34:L1:M006 N34:L1:M007
N34:L1:M008
N34:L1:D009
S0-2
N34:L1:M020
Security System Unlock Doors
AOM
RField
Verify
F F
Feeds to 1st Floor
Feeds to 1st Floor - Pull Station
Feeds to 1st Floor - Strobe/Heat
F Feeds to 1st Floor
Feeds to 1st Floor
P S L.I.U
To Sub-Basement
J
J J
J
J
J
J
J JJJJJ
J
J
J
J
A
P
A
A A
A A
A
A
A
A
2S
F
AA
S,V
S,V
S
S,V
S,VA
S,V
S,V
S,V
S,V
S,V
S,V
S,V A
S,V
S,V
S,V
F
F
F
F
S,V
S,V S,V
S,V
F190° H
STAGE
104 AUDITORIUM
LOBBY
RESTROOM
GAME
ROOM
103A
F
F
F
S0-3 V0-3
S15 S0-3
S75 1W
S75 1W
Folding Accordion
Door
S75 1W
BALCONY
Fed From BasementS,V
N34:L1:M001
N34:L1:M003N34:L1:M002
S0-3 V0-3
S0-3 V0-3
S0-3 V0-3
S30
S0-3 V0-3
To
FACP S,V
S,V
Fed From Basement
To Upper Lvl
Lounge/Mezz
Fed From Basement
S,V
S75C
F135° H Upstairs
FSA
J
A
A Fed From Basement
A
Fed From Basement
TRANSFORMER
VAULT
B203A
CB2-1
STORAGE
B201
STORAGE
B202
B202A
MECH/
PIPING
B203
F S15
WP
S P
F135° H
MECH/
PIPING
VS
WF
N34:L1:M040
N34:L1:M055 VS Field verify
Fire Sprinkler connections.
N34:L1:M046
VS
N34:L1:M057
VS
N34:L1:M047
VS
AIM
AIM
AIM
AIM
AIM
Backflow Preventer
D
DD
D
D
D
PIV
D PS
PS
LA
N34:L1:M045
N34:L1:M050
AIM
DAIM
Main - Fire Sprinkler System
D WFAIM S75
1W
WP
N34:L1:M042
D WFAIM
VSAIM D
N34:L1:M041
N34:L1:M049
N34:L1:M048
VSAIM D
D WFAIM
N34:L1:M043
S,V
S,VN34:L1:M004
N34:L1:D004
N34:L1:D005
S0-1 V0-1
S0-1 V0-1
S0-1 V0-1
To
FACP
VSAIM D
N34:L1:M059
D WFAIM
N34:L1:M058
D
S75
AIM
LA
J J J J J
J
J J
A
A
A
A
A
A
LOUNGE
RESTROOM
104A
MEZZANINE
RADIO TRAN.
STORAGE
202A
HVAC ROOM
202B
W. WING
DRESS RM
W. WING
RR
204A
E. WING
DRESS RM
E. WING
RR
203A
OPEN TO
BELOW
S15 S0-3
S15 S0-3
S15 S0-3
S75 1W
S30
To First Floor Lobby S,V
S,V
S,V
S,V
S,V
18'-3" AFF
9'-6" AFF
8'-3" AFF
7'-10" AFF
11'-2" AFF
S0-3 V0-3
S0-3 V0-3
From First Floor Lobby
7'-10" AFF
Fed From Basement
S,V
S,V
J
2S,2V
S,V
Number of Sheets:
By
Installing Fire Alarm System Contractor:
Date
Drawn By:
Drawn Date:
Scale:
Drawing No.
Revisions Description
Authority Having Jurisdiction:
Project Contacts
DHL
04/29/2024
VA
W al la
W al la
B ui ld in g
W ai nw rig ht
D riv e W al la
W al la , W
A
Li fe
S af et y
(F ire
A la rm S ys te m ) D ra w in gs
COPYRIGHT NOTICE
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN
CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF
VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED
OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF
VULCAN FIRE
Reviewed by:
ENGINEERED SYSTEM DISTRIBUTION
by Honeywell
TM
Vulcan Project #: FI23-013
U .S
.D ep ar tm en t o f V et er an s A ffa irs
Fi re
A la rm S ys te m R ep la ce m en t -
P ha se B
Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362
(509) 524-4603
Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814
(208) 277-0171
GC
L ice ns e:
V
UL
CA
F*
0M
El ec
L ice ns e:
V
UL
CA
F*
W
EB
SI
TE
: w w w
.v ul ca nf ire us
.c om
PH
ON
E
(2
) 2
-0
Ea st H az el
A ve nu e, S ui te
1, C oe ur d 'A le ne
, I da ho
Record Drawings (04/23/2025)
1/8" = 1'-0"
FA-1.1
Scale: 1/4'' = 1'-0''
10 2 4 8 16
First Floor - Fire Alarm System Plan
Scale: 1/4'' = 1'-0''
10 2 4 8 16
Sub-Basement - Fire Alarm System Plan
Scale: 1/4'' = 1'-0''
10 2 4 8 16
Upper Level - Fire Alarm System Plan
Scale: 1/4'' = 1'-0''
10 2 4 8 16
Basement - Fire Alarm System Plan
Dedicated
120VAC
SS
FACP FARC
MAP
EP
GUTTER
CPU2-640
HS-NCM-MF
NCA-2
DVC / CMIC-1
DAA2-7525
EVAC
BATT
Battery Battery
Addressable Pull Station
321(-)
A ANBG-12LX
Strobe S0-2
Speaker V0-2 V
S
Backflow Preventer
VS
47k
Main - Fire Sprinkler System
SL
C
Lo op
A
B300-6
From
Device SLC Loop previous
Device SLC Loop To next
A
A
Addressable Smoke or Heat Detector
RA
F F F
V
S15C
4.7k
20k
Speaker/Strobe
Speaker
Strobe
VV
S S
Strobe
Strobe
S_ S_
D WF 47k
VS D
Main D PS
PS
LA
WF
47k
47k
S
S15C S15C
A
D
AIM
AIM D
A
T1
T2
T4 T5
LOOP
T6 T7 T8
T9 T10
ADDRESS
T3
T11
FMM-1
Fire Sprinkler Valve Tamper
D 0 15 14
6 7 8 9 9876
1 0
TENS ONES
A
A
Fire Sprinkler System - Valve Tamper with FMM-1 Monitor Module
F
To Fiber Network Bldg. 75
FTo Fiber Network Bldg. 77
15 1515
A
AIM
First Floor
Sub-Basement
First Floor
Sub-Basement
BasementBasement
Elevator Controls #1
120VAC Shunt Trip Power Source
Primary Recall (Steady) Alternate Recall (Steady)
Shunt Trip Breaker
Fire Light Indicator (Flashing)
R
FATCXP6-R
Sp ar e Sp ar e
47k
R D
A
AIM
Upper LevelUpper Level
Strobe S0-1
Speaker V0-1 V
S
S75
WP
S15
1W S75
4.7k
20k
V V
V
S S
VS
VS
AIM
AIM
D
D
PIV
D WFAIM
D WFAIM
VSAIM D
D WFAIM
VSAIM D
D WFAIM47k
47k
47k
47k
47k
47k
47k
47k
A
AIM
P S
F135°
AH
F
WP
VSAIM D 47k
VSAIM D 47k
A
P S
P S
P S
F135° H
F135° H
S75C S75C S30C S15C 15C
Strobe S0-3
Speaker V0-3 V
S
S30
S30 15 1W S75
1W S75
1W S75
15 15
15 S75C 1W S75
4.7k
20k
A
P S
P S
F135°
H AFF
P S
A
P S
P S
P S
V
S S S S
VV
AIM
47k
D
Security System Unlock Doors
AOM
R
Sound System
Shutdown
AOM
R
F
NCA
2AD,AP
SYSTEM INPUTS
PANEL FUNCTIONS
ALARM DEVICES
SYSTEM RESET
SYSTEM SILENCE
"ALL SYSTEMS NORMAL"
SMOKE DETECTORS
SUPERVISORY DEVICES
TROUBLE FUNCTIONS
ABNORMAL CIRCUIT OR DEVICE
FIRE ALARM SYSTEM AC POWER FAILURE
FIRE ALARM SYSTEM LOW BATTERY
SP
EA
KE
RS
A
ND
S
TR
OB
ES
S
TO
P
YE
LL
OW
LE
D W
IL
L F
LA
SH
A
ND
YE
LL
OW
LE
D W
IL
L F
LA
SH
A
ND
W
IL
L T
UR
N
ON
, U
NT
IL
S
IL
EN
CE
D.
RE
D
LE
D
AN
D
AU
IB
LE
S
OU
ND
ER
HI
ST
OR
Y
LO
G:
SYSTEM OUTPUTS
(S
YN
CH
RO
NI
ZE
D
AN
D
VO
IC
E
EV
AC
TE
MP
OR
AL
P
AT
TE
RN
AC
TI
VA
TE
S
BU
IL
DI
NG
S
IN
TE
RI
OR
N
OT
IF
IC
AT
IO
N
DE
VI
CE
S
REQUIRED FA CONTROLFACP FUNCTION
AC
TU
AT
ES
T
RO
UB
LE
C
ON
DI
TI
ON
A
T
CO
NT
RO
L P
AN
EL
PU
LS
IN
G
SO
UN
DE
R
W
IL
L T
UR
N
ON
, U
NT
IL
A
CK
NO
W
LE
DG
ED
AC
TU
AT
ES
S
UP
ER
VI
SO
RY
C
ON
DI
TI
ON
A
T
CO
NT
RO
L P
AN
EL
GR
EE
N
AC
P
OW
ER
IN
DI
CA
TO
R
IS
LI
T
ST
EA
DI
LY
ON
C
ON
TR
OL
P
AN
EL
CH
AR
AC
TE
R
LC
D
DI
SA
PL
Y
DI
SP
LA
Y
TH
E
CU
ST
OM
M
ES
SA
GE
"A
LL
S
YS
TE
MS
N
OR
MA
L"
AC
TU
AT
ES
A
LA
RM
C
ON
DI
TI
ON
A T
CO
NT
RO
L P
AN
EL
RE
CO
RD
IN
G
OF
T
HE
E
VE
NT
IN
S
YS
TE
MS
M
EM
OR
Y
PU
LS
IN
G
SO
UN
DE
R
W
IL
L T
UR
N
ON
, U
NT
IL
A
CK
NO
W
LE
DG
ED
FI
RE
A
LA
RM
C
ON
TR
OL
P
AN
EL
R
ET
UR
NS
T O
NO
RM
AL
NOTIFICATION
MANUAL PULL STATION
A B C D E F G H I J K L M N O P Q R
* FIRE SPRINKLER SYSTEM - ZONED WATERFLOW SWITCH (LATCHING)
FIRE SPRINKLER SYSTEM - MAIN WATERFLOW SWITCH (LATCHING)
Fire Alarm System Matrix
FIRE SPRINKLER SYSTEM - VALVE TAMPER SWITCH
MICROPHONE ACTIVATION WITH CIRCUIT SELECTION SWITCH
(C
ON
TA
CT
ID
) T
O U.
L.
CL
AS
S
CE
NT
RA
L S
TA
TI
ON
(C
ON
TA
CT
ID
) T
O U.
L.
CL
AS
S
CE
NT
RA
L S
TA
TI
ON
(C
ON
TA
CT
ID
) T
O U.
L.
CL
AS
S
CE
NT
RA
L S
TA
TI
ON
(C
ON
TA
CT
ID
) T
O U.
L.
CL
AS
S
CE
NT
RA
L S
TA
TI
ON
TR
AN
SM
IT
S W
AT
ER
FL
OW
C
ON
DI
TI
ON
V
IA
C
EL
LU
LA
R
CO
MM
UN
IC
AT
OR
TR
AN
SM
IT
S
TR
OU
BL
E
CO
ND
IT
IO
N
VI
A
CE
LL
UL
AR
C
OM
MU
NI
CA
TO
R
TR
AN
SM
IT
S
SU
PE
RV
IS
OR
Y
CO
ND
IT
IO
N
VI
A
CE
LL
UL
AR
C
OM
MU
NI
CA
TO
R
TR
AN
SM
IT
S
AL
AR
M
CO
ND
IT
IO
N
VI
A
CE
LL
UL
AR
C
OM
MU
NI
CA
TO
R
AN
NU
NC
IA
TO
RS
(B
OT
H
SP
EA
KE
RS
A
ND
S
TR
OB
ES
W
IL
L S
TO
P)
NO
TI
FI
CA
TI
ON
A
PP
LI
AN
CE
S
SH
AL
L B E
SI
LE
NC
EA
BL
E
AT
T
HE
FA
CP
O
R
- ELEVATOR LOBBY - (Basement)
- SPOT TYPE DETECTORS, (All, except as specifically noted below)
- ELEVATOR LOBBY - (First Floor)
- ELEVATOR MACHINE ROOM (Basement)
- TOP OF ELEVATOR SHAFT
EL
EV
AT
OR
R
EC
AL
L (
PR
IM
AR
Y)
EL
EV
AT
OR
R
EC
AL
L T
O
FI
RS
T
FL
OO
R
EL
EV
AT
OR
R
EC
AL
L (
AL
TE
RN
AT
E)
EL
EV
AT
OR
R
EC
AL
L T
O
BA
SE
ME
NT
AC
TI
VA
TE
E
LE
VA
TO
R
FI
RE
D
EP
AR
TM
EN
T
(F
LA
SH
IN
G) L
IG
HT
AC
TI
VA
TE
E
LE
VA
TO
R
FI
RE
D
EP
AR
TM
EN
T (S
TE
AD
Y) L
IG
HT
PR
IO
R
TO
S
PR
IN
KL
ER
H
EA
D
AC
TI
VA
TI
ON
SH
UT
DO
W
N
PO
W
ER
T O
AF
FE
CT
ED
E
LE
VA
TO
R
S
HEAT DETECTORS
- ELEVATOR MACHINE ROOM (Basement)
- BOTTOM OF ELEVATOR SHAFT
ON
YX
W
OR
KS
S
TA
TI
ON
IN
B
UI
LD
IN
G
SE
CU
RI
TY
O
FF
IC
E
TR
AN
SM
IT
S
SY
ST
EM
C
ON
DI
TI
ON
V
IA
FI
BE
R
NE
TW
OR
K
TO
T
- SPOT TYPE DETECTORS, (All, except as specifically noted below)
SE
CU
RE
D
DO
OR
S
SE
ND
S
IG
NA
L T
O
SE
CU
RI
TY
S
YS
TE
M
- U
NL
OC
K
AL
L
FIRE SPRINKLER SYSTEM - DRY SYSTEM - LOW AIR
DI
SP
LA
Y
AC
TI
VI
TY
O N
NE
TW
OR
K
AN
NU
NC
IA
TO
R
SE
ND
S
IG
NA
L T
O
SH
UT
DO
W N
AU
DI
TO
RI
UM
S
OU
ND
S
YS
TE
M
U
Number of Sheets:
By
Installing Fire Alarm System Contractor:
Date
Drawn By:
Drawn Date:
Scale:
Drawing No.
Revisions Description
Authority Having Jurisdiction:
Project Contacts
DHL
04/29/2024
VA
W al la
W al la
B ui ld in g
W ai nw rig ht
D riv e W al la
W al la , W
A
Li fe
S af et y
(F ire
A la rm S ys te m ) D ra w in gs
COPYRIGHT NOTICE
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN
CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF
VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED
OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF
VULCAN FIRE
Reviewed by:
ENGINEERED SYSTEM DISTRIBUTION
by Honeywell
TM
Vulcan Project #: FI23-013
U .S
.D ep ar tm en t o f V et er an s A ffa irs
Fi re
A la rm S ys te m R ep la ce m en t -
P ha se B
Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362
(509) 524-4603
Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814
(208) 277-0171
GC
L ice ns e:
V
UL
CA
F*
0M
El ec
L ice ns e:
V
UL
CA
F*
W
EB
SI
TE
: w w w
.v ul ca nf ire us
.c om
PH
ON
E
(2
) 2
-0
Ea st H az el
A ve nu e, S ui te
1, C oe ur d 'A le ne
, I da ho
Record Drawings (04/23/2025)
1/8" = 1'-0"
FA-2.1
Riser Diagram / Details - Fire Alarm System
VOLTAGE DROPS ARE CALCULATED AT 16VDC.
L= ONE WAY LENGTH OF CIRCUIT(FEET)
WHERE VD= VOLTAGE DROP
R= 3.19 OHMS PER THOUSAND
I= LOAD CURRENT(AMPERES)
AFTER DETERMINING THE LENGTH OF THE HORN/STROBE CIRCUIT, USE
THE FOLLOWING FORMULA TO CALCULATE THE VOLTAGE DROP.
2xLxRxIVD=
LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD
ALLOWS FOR A SMALL MARGIN OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL
CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN ON THE SHOP SUBMITTAL
DRAWINGS. IF ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE
CIRCUIT LENGTH, CONTACT VULCAN FIRE.
VOLTAGE-DROP CALCULATION NOTE:
** STARTING VOLTAGE-DROP CALCULATIONS IS 20.4 PER UL 864, 9TH EDITION STANDARDS FOR FIRE ALARM
CONTROL PANELS.
AutoCAD SHX Text 47k
AutoCAD SHX Text
EOL
AutoCAD SHX Text Resistor
| Sheets and Views |
| FI23-013 VA Walla Walla Bldg-78 FA_Record-FA-0.0 (1) |
| FI23-013 VA Walla Walla Bldg-78 FA_Record-FA-1.1 (2) |
| FI23-013 VA Walla Walla Bldg-78 FA_Record-FA-2.1 (3) |
File details come from the government source that posted it. Updated .