FI23-013-VA-Walla-Walla-Bldg-78-FA_Record.pdf

PDF 5 MB Posted

Attached to
H212 Fire Alarm Inspections, Testing, Maintenance & Repairs - Walla Walla VA - Dept of Veterans Affairs
Solicitation number
36C26025Q0599
Issued by

About this file

These are record drawings for a fire alarm system replacement project at the VA Walla Walla Medical Center, Building 78, located at 77 Wainwright Drive in Walla Walla, Washington. The project involves a comprehensive fire alarm system upgrade, including replacing existing copper cabling with new fiber optic infrastructure, installing new fire alarm control panels with campus-wide network monitoring, and replacing all existing fire alarm devices such as pull stations, detectors, relay modules, and associated conduit and cabling.

The new Notifier fire alarm system will include voice evacuation notification appliances throughout the building, smoke and heat detectors installed per code requirements, manual pull stations at building exits, and an annunciator with campus-wide monitoring located in the main office basement. The system will provide monitoring of the fire sprinkler system, with tamper switches generating supervisory signals. The project covers multiple building levels including basement, sub-basement, first floor, and upper level, with devices strategically placed to ensure comprehensive fire detection and notification. The system will integrate with elevator controls, security systems, and central monitoring, and is designed to comply with 2018 IBC, IFC, NFPA 101, and other relevant safety standards.

View the file

Other files

File Type Posted
S06 Amendment 36C26025Q0599 0002.pdf PDF
S02 RFQ 36C26025Q0599_1 Rev 7-31-2025.pdf PDF
S06 Amendment 36C26025Q0599 0001.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-135-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-65-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-69-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-140-FA_RECORD.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-143-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-66-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-31-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-82-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-49-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-81-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-75-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-T1-and-T2-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-T-7-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-80-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-145-FA_Record.pdf PDF
S02 RFQ 36C26025Q0599_1.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-76-FA.pdf PDF
PP_Questionnaire.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-41-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-74-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-77-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-48-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-68-_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-63-FA_Record.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Number of Sheets:

By

Installing Fire Alarm System Contractor:

Date

Drawn By:

Drawn Date:

Scale:

Drawing No.

Revisions Description

Authority Having Jurisdiction:

Project Contacts

DHL

04/29/2024

VA

W al la

W al la

B ui ld in g

W ai nw rig ht

D riv e W al la

W al la , W

A

Li fe

S af et y

(F ire

A la rm S ys te m ) D ra w in gs

COPYRIGHT NOTICE

ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN

CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF

VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED

OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF

VULCAN FIRE

Reviewed by:

ENGINEERED SYSTEM DISTRIBUTION

by Honeywell

TM

Vulcan Project #: FI23-013

U .S

.D ep ar tm en t o f V et er an s A ffa irs

Fi re

A la rm S ys te m R ep la ce m en t -

P ha se B

Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362

(509) 524-4603

Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814

(208) 277-0171

GC

L ice ns e:

V

UL

CA

F*

0M

El ec

L ice ns e:

V

UL

CA

F*

W

EB

SI

TE

: w w w

.v ul ca nf ire us

.c om

PH

ON

E

(2

) 2

-0

Ea st H az el

A ve nu e, S ui te

1, C oe ur d 'A le ne

, I da ho

Record Drawings (04/23/2025)

N/A

FA-0.0

Site Plan

General Notes:

Drawing Notes:

Fire Alarm Control Panel Terminations:

Scope of Work:

All wiring runs shown on the fire alarm shop drawings are conceptual only. They do not and are not intended to be actual wire runs or conduit runs. Device interconnect is intended to show only sequence of device connections and type of wire.

Please review both the floor plans and the riser diagram drawings to resolve any conflicts or questions that may come up. If the drawings do not answer your questions, please call Vulcan Fire for help to answer your questions.

Electrical Contractor is advised not to complete terminations at the Fire Alarm Control Panel. Terminations will be completed by a qualified Vulcan Fire Technician.

Code Analysis:

Edition of Codes:

Number of Stories:

Edition of Standards:

Occupancy Type: B, Business (Clinic, Exam, Offices) S-1 Storage (Storage Closets) A-1 Assembly (Auditorium)

2018 IBC, IFC, IMC

2018 NFPA 101

City of Walla Walla Amendments 2009 ANSI 117.1 Guidelines for Accessible & Useable

Yes, Fully Fire Sprinklered

1 w/ Unoccupied Basement

Visual Notification: Public Mode

Wire runs are indicated by AlphaNumeric designations.

power run of "2#__ " cable. A designation of "P3" would indicate another individual run of "2#__ " cable.

"2#__Twisted AND a run of 2#__ " cable.

A designation of "A,P2", would refer to a run of

The wire Gauge of any wire run is determined by the

A designation of "P2", would refer to a individual pair, 2#__ Twisted" cable.

A designation of "2A", would refer to a run of "2 length of the wire run and the power load on that run.

A typical wire run designated as "A", would refer to a single run of "2 #__ Twisted" cable.

For example:

A,P2

P2,P3

A

2A

Wire Chart:

Audible Notification: Voice Evac - Temporal 3 Pattern / Synchronized

Type of FA System: New Fire Alarm Addressable System

Index of Drawings Drawing Name

Drawing Number

Cover SheetCover SheetFA-0.0 FA-1.1 Basement - Fire Alarm Plan /

Sub-Basement - Fire Alarm Plan / First Floor - Fire Alarm Plan / Second Floor- Fire Alarm Plan

Temporal Pattern Notification Device Numbering:

(IE: HORN/STROBE)

AUDIBLE/VISUAL DEVICE

(IE: STROBE ONLY)

AUDIBLE DEVICE

(IE: HORN ONLY)

WITH THE REQUIREMENTS FOR VISUAL DEVICES.

1. ADA ACCESSIBILITY GUIDELINES HAVE ACCEPTED NFPA 72 GUIDELINES AS "EQUIVALENT FACILITATION".

3. MEASUREMENT IS TO THE BOTTOM OF THE DEVICE.

2. NFPA 72 STATES THAT COMBINATION AUDIBLE/VISUAL DEVICES SHALL BE MOUNTED IN ACCORDANCE

NOTES:

AFF = ABOVE FINISHED FLOOR0" (FLOOR)

NFPA 72

A

90" A.F.F.

A/V

96" A.F.F.

80" A.F.F.

NFPA 72

MAX.

MIN.

V

VISUAL DEVICE

CEILING

6" BELOW

CEILING

Example of Proper Mounting for Audible/Visual Devices:

Example of Junction Box Detail (FA):

If Applicable (Use for eample only)

Sheet Number

Walla Walla, WA 99362

U.S. Department Of Veterans Affairs VA Medical Center

77 Wainwright Drive

Owner

Fire Protection System:

Square Footage:

FA System Required: Code-Required

Project Manager: Dave Clem

GDM of Oregon 1584 McNeil Street, Suite 200

DuPont, WA 98327

Architect / Engineer

3,264 GSF

Protected Premises Fire Alarm Systems (Wiring):

Mounted Candela Rating:

S150 = 150 Candela S177 = 177 Candela S185 = 185 Candela

S135 = 135 Candela

S115 = 115 Candela S110 = 110 Candela S95 = 95 Candela S75 = 75 Candela S30 = 30 Candela S15 = 15 Candela

Ceiling S15C S15

Wattage Speaker 1W Tap

Guard WireWG WeatherproofWP

VOICE CIRCUIT

V 2

2S

POWER SUPPLY NUMBER

STROBE CIRCUIT

CIRCUIT NUMBER

AMPLIFIER NUMBER

CIRCUIT NUMBER

("T" Tap)

Class B

Class B

P

F P

VS VSAIM

Class B

IDC - Initiating Device Circuit Manual Pull Stations, Fire Sprinkler System, Etc.

NAC - Notification Appliance Circuit Horns, Bells, Strobes, Etc.

SLC - Signaling Line Circuit Intelligent (Addressable) Devices

Only in J-Box (per Owner)

FS

S

Where used, End-Of-Line Resistors shall be labeled "EOL" on the Device (per Owner)

Building 78 77 Wainwright Drive, Walla Walla, WA 99362

Fire Alarm System Replacement

The scope of work for this project is to replace the existing campus fire alarm system with a new fire alarm system throughout. The existing copper cabling backbone infrastructure will be replaced with new fiber optic cabling. Each building will be provided with new fire alarm control panels connected to the campus network. A new campus wide computer monitoring and control system will be provided in Building 78.

Existing fire alarm devices such as pull stations, detectors, relay modules, monitor modules, flow and tamper switch interfaces, and associated conduit, boxes and cabling shall be demolished and replaced with new devices.

Building 78 Fire Alarm System:

The new Notifier fire alarm system in Building 78 will be replacing the existing fire alarm system. Voice evacuation notification appliances will be installed throughout the entire building, which will alert the occupants in the event of a fire. The FACP will provide monitoring of the fire sprinkler system. Smoke and Heat Detectors will be installed where required per codes. New manual pull station will be installed at building exits. An annunciator with campus wide monitoring and control is provided in the Main Office in the Basement.

The fire sprinkler tamper switches will cause a supervisory signal when activated. These devices will report as a supervisory signal.

The fire alarm system shall be monitored through a central monitoring company of the owners choosing prior to the final inspection.

N

All intelligent and or addressable Fire Alarm Devices must be placed in protected areas with ambient temperature ranging from 32° to 120°. Weatherproof Fire Alarm Devices have temperature rating from -40° to 151° in wet or dry applications.

Do not place smoke detectors within 3 feet of air supply registers and diffusers.

All intelligent devices shall be interconnected as shown on the riser on-line diagram. Each intelligent device is designed with an address. T-Tapping is permitted on SLC Loop (Class "B") only.

Wire runs show interconnected of fire alarm devices only. Wiring does not represent conduit runs.

Electrical Contractor is responsible for proper connection of equipment provided by others.

(RL) Indicates Existing Device to be relocated to new location.

(R) Indicates Device to be removed and returned to Owner.

(E) Indicates Device existing to remain (shown in gray scale).

(N) Indicates New Device.

(RR) Indicates Remove Existing Device and replace with new Device. Return any removed equipment to Owner.

Typical Device Mounting Height:

NFPA 2016

Wall Mounted AUDIBLE device.

Top of Individual Device

MAX

4'-0"

"ADA"

(48")

Top of Device of the Same Lens

Top of Unit

Top of Cabinet

To Handle of Device Per NFPA 72 from (AFF) Above All heights measured

NOT TO SCALE

Finished Floor

BOTTOM

OF

6'-0"

80" TO

MIN* (72")

LENS

See Note #5

7'-0"

TO TOP

OF

Approx.96"

MAX*

(84")LENS

(6")

THAN

BELOW

CEILING

(90")

AND

LESS

THAN

NOT

LESS

NOT

(64") 5'-4" or 80" MIN. to Bottom A/V or Visual Only Devices

MAX 96" to Top of Lens for all

#1) HEIGHTS SHOWN ARE LISTED IN NFPA STANDARDS 2016.

#2) MOUNTING HEIGHTS LISTED IN SPECIFICATIONS OR SHOWN ON THE

ARCHITECTURAL ELEVATIONS SHALL GOVERN. ANY DISCREPANCY SHALL BE

BROUGHT TO THE ATTENTION OF THE AHJ AND THE ENGINEER OF RECORD.

#3) WALL MOUNTED ADA STROBES & HORN/STROBES ARE TO BE PLACED

A MINIMUM OF 80" ABOVE FINISHED FLOOR MEASURED AT THE BOTTOM OF

THE LENS OR 6" BELOW THE CEILING TO THE TOP OF THE LENS,

WHICHEVER IS LOWEST. THE MAXIMUM HEIGHT MEASURED AT THE TOP OF

THE LENS SHALL NOT EXCEED 96".

#4) IN SLEEPING ROOMS A STROBE MOUNTED LESS THAN 24" FROM THE

CEILING SHALL BE AT LEAST 177CD. STROBES MOUNTED 24" OR BELOW

SHALL BE AT LEAST 110 CD. A STROBE SHALL BE MOUNTED WITHIN 16FT

OF THE PILLOW.

#5) REMOTE LIGHTS, TEST STATIONS AND MODULES SHOULD BE MOUNTED

SO AS TO BE ACCESSIBLE, YET ABOVE EASY REACH TO PREVENT

VANDALISM.

#6) CEILING MOUNT VISIBLE DEVICES SHALL BE SPACED ACCORDING TO

2016 NFPA 72.

FSA

FACFACP RPS

AIM AOM

F

RL

S15H15 15MC15

RT

J DM

MAP FTR

C

AOM

R

S

(48") 4'-0"

*MAX

(42") 3'-6"

*MIN

U.S. Department of Veterans Affairs

VA WALLA WALLA - FIRE LIFE SAFETY - PHASE B Fire Alarm Systems Interconnect Drawings

X

X X

X X

X

X

X

X

XX X

X

X

X

X

X

X

STATE NURSING HOME

STATE NURSING HOME

STATE NURSING HOME

STATE NURSING HOME

N U

R

SIN

G H

O M

E

FU

TU

R E

BL

D

G

7 49 48

66T-7

77T-1

T-2

756968

116119

121126125124

109CM

147 146

W

SITE

78Setting Initiating Device Addresses:

D:L1: 501

ONESTENS

7 8 9

00 15

D = Detector M = Monitor

Device AddressData Loop Number

DIALS ARE

LOCATED ON THE

BACK OF EACH

DEVICE

N1:

Node Number

2016 NFPA 72, 2020 NFPA 70 (NEC), VA Fire Protection Manual

FA-2.1 Riser Diagram / Details / Load Calculations / Speaker Calculations / Fire Alarm Matrix

MAP

BATT

S P

FACP

EVAC

F

AIM

S15C

VS

WF

SS

FARC

Indicates Circuit Continuation Indicates Home Run to FACP

PS

PS LA

WF

S30C

S75C

FATC

F135°

AOM

R

R

WP F

15C

S15

S75

S15

WP

NCA

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text PRV Vault

AutoCAD SHX Text F/A

AutoCAD SHX Text 8"

AutoCAD SHX Text Caps

AutoCAD SHX Text Tank

AutoCAD SHX Text Fuel

AutoCAD SHX Text F/A

AutoCAD SHX Text Valves

AutoCAD SHX Text

PRV

AutoCAD SHX Text F/A

General Note:

* All addressable devices require SLC Loop (A-wire) from the FACP to operate. For help, please refer to riser diagram for reference.

* Do not route conduit into the bottom of any fire alarm system component cabinets.

* Tap all speakers at 1/2 watt - 25 volts unless otherwise indicated at individual device.

* Contractor may reuse existing pathways where available. Verify with system designer prior to adding additional devices or extending circuits to ensure voltage drop calculations are within acceptable limits.

1) Section of NFPA 72, National Fire Alarm Code requires units to be provided with smoke detection in areas that are not continuously occupied.

2) Provide Dedicated 120VAC circuit to the FACP label the Dedicated circuit breaker "Fire Alarm." In red with lockout. Location of breaker shall be noted at FACP.

3) Fiber Network routing to be field coordinated.

4) Detector is to activate Elevator Recall Functions.

5) Detector is to activate Elevator Shunt Trip. Mount within 24" of Sprinkler

Head.

6) Visual Notification omitted in areas without existing devices or ADA requirements to comply with VA Fire Protection Manual Section 7.3.F.l.4.

Field verify single person offices with hearing-impaired occupants.

Flag Notes: (Some flag notes may not appear on every sheet)

Addressing Legend:

D = Detector M = Module

Module/Device Number M01L01

Loop Number N01Node Number

Dedicated

120VAC

SS

FARC

MAP

EP

To Bldg. Devices (SLC Loop) A

CPU2-640

HS-NCM-MF

NCA-2

DVC / CMIC-1

DAA2-7525 FACP

Spkr Crkts V0-1, V0-2, V0-3, V0-4BATT

NAC Crkts S0-1, S0-2, S0-3, S0-4, To Fiber Network Patch Panel2F

Components located inside of

FACP

EVAC

OFFICE

B104

OFFICE

B103

LOCKER

ROOM

B105 KITCHEN

B106

HVAC

VAULT

B107

B101A

IT/COMM

B102

OFFICE

101D

MAIN

OFFICE

B101 OFFICE

B101C

BREAK

B101BCB1-1

RESTROOM

B110STORAGE

B108

CB1-1

VAULT/

EMER/GEN

B111

S15 S0-2

S15 S0-2

S15 S0-2

STORAGE

S75C S0-2 V0-2

CELL

B101E

15C

S15C

S0-2 V0-2

F

NCA

S P

S30C

S0-2 V0-2

S15C

S0-2 V0-2

S15C S0-2 V0-2S15C

S0-2 V0-2

S75C

S0-2 V0-2

To

FACP

2AD,AP

8'-8" AFF

7'-9" AFF

8'-8" AFF

7'-11" AFF

8'-8" AFF 8'-2" AFF

8'-3" AFF

8'-5" AFF

7'-3" AFF

9'-8" AFF

7'-11" AFF

7'-10" AFF

7'-10" AFF

8'-3" AFF

8'-1" AFF

N34:L1:D010

N34:L1:M005

N34:L1:M006 N34:L1:M007

N34:L1:M008

N34:L1:D009

S0-2

N34:L1:M020

Security System Unlock Doors

AOM

RField

Verify

F F

Feeds to 1st Floor

Feeds to 1st Floor - Pull Station

Feeds to 1st Floor - Strobe/Heat

F Feeds to 1st Floor

Feeds to 1st Floor

P S L.I.U

To Sub-Basement

J

J J

J

J

J

J

J JJJJJ

J

J

J

J

A

P

A

A A

A A

A

A

A

A

2S

F

AA

S,V

S,V

S

S,V

S,VA

S,V

S,V

S,V

S,V

S,V

S,V

S,V A

S,V

S,V

S,V

F

F

F

F

S,V

S,V S,V

S,V

F190° H

STAGE

104 AUDITORIUM

LOBBY

RESTROOM

GAME

ROOM

103A

F

F

F

S0-3 V0-3

S15 S0-3

S75 1W

S75 1W

Folding Accordion

Door

S75 1W

BALCONY

Fed From BasementS,V

N34:L1:M001

N34:L1:M003N34:L1:M002

S0-3 V0-3

S0-3 V0-3

S0-3 V0-3

S30

S0-3 V0-3

To

FACP S,V

S,V

Fed From Basement

To Upper Lvl

Lounge/Mezz

Fed From Basement

S,V

S75C

F135° H Upstairs

FSA

J

A

A Fed From Basement

A

Fed From Basement

TRANSFORMER

VAULT

B203A

CB2-1

STORAGE

B201

STORAGE

B202

B202A

MECH/

PIPING

B203

F S15

WP

S P

F135° H

MECH/

PIPING

VS

WF

N34:L1:M040

N34:L1:M055 VS Field verify

Fire Sprinkler connections.

N34:L1:M046

VS

N34:L1:M057

VS

N34:L1:M047

VS

AIM

AIM

AIM

AIM

AIM

Backflow Preventer

D

DD

D

D

D

PIV

D PS

PS

LA

N34:L1:M045

N34:L1:M050

AIM

DAIM

Main - Fire Sprinkler System

D WFAIM S75

1W

WP

N34:L1:M042

D WFAIM

VSAIM D

N34:L1:M041

N34:L1:M049

N34:L1:M048

VSAIM D

D WFAIM

N34:L1:M043

S,V

S,VN34:L1:M004

N34:L1:D004

N34:L1:D005

S0-1 V0-1

S0-1 V0-1

S0-1 V0-1

To

FACP

VSAIM D

N34:L1:M059

D WFAIM

N34:L1:M058

D

S75

AIM

LA

J J J J J

J

J J

A

A

A

A

A

A

LOUNGE

RESTROOM

104A

MEZZANINE

RADIO TRAN.

STORAGE

202A

HVAC ROOM

202B

W. WING

DRESS RM

W. WING

RR

204A

E. WING

DRESS RM

E. WING

RR

203A

OPEN TO

BELOW

S15 S0-3

S15 S0-3

S15 S0-3

S75 1W

S30

To First Floor Lobby S,V

S,V

S,V

S,V

S,V

18'-3" AFF

9'-6" AFF

8'-3" AFF

7'-10" AFF

11'-2" AFF

S0-3 V0-3

S0-3 V0-3

From First Floor Lobby

7'-10" AFF

Fed From Basement

S,V

S,V

J

2S,2V

S,V

Number of Sheets:

By

Installing Fire Alarm System Contractor:

Date

Drawn By:

Drawn Date:

Scale:

Drawing No.

Revisions Description

Authority Having Jurisdiction:

Project Contacts

DHL

04/29/2024

VA

W al la

W al la

B ui ld in g

W ai nw rig ht

D riv e W al la

W al la , W

A

Li fe

S af et y

(F ire

A la rm S ys te m ) D ra w in gs

COPYRIGHT NOTICE

ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN

CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF

VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED

OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF

VULCAN FIRE

Reviewed by:

ENGINEERED SYSTEM DISTRIBUTION

by Honeywell

TM

Vulcan Project #: FI23-013

U .S

.D ep ar tm en t o f V et er an s A ffa irs

Fi re

A la rm S ys te m R ep la ce m en t -

P ha se B

Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362

(509) 524-4603

Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814

(208) 277-0171

GC

L ice ns e:

V

UL

CA

F*

0M

El ec

L ice ns e:

V

UL

CA

F*

W

EB

SI

TE

: w w w

.v ul ca nf ire us

.c om

PH

ON

E

(2

) 2

-0

Ea st H az el

A ve nu e, S ui te

1, C oe ur d 'A le ne

, I da ho

Record Drawings (04/23/2025)

1/8" = 1'-0"

FA-1.1

Scale: 1/4'' = 1'-0''

10 2 4 8 16

First Floor - Fire Alarm System Plan

Scale: 1/4'' = 1'-0''

10 2 4 8 16

Sub-Basement - Fire Alarm System Plan

Scale: 1/4'' = 1'-0''

10 2 4 8 16

Upper Level - Fire Alarm System Plan

Scale: 1/4'' = 1'-0''

10 2 4 8 16

Basement - Fire Alarm System Plan

Dedicated

120VAC

SS

FACP FARC

MAP

EP

GUTTER

CPU2-640

HS-NCM-MF

NCA-2

DVC / CMIC-1

DAA2-7525

EVAC

BATT

Battery Battery

Addressable Pull Station

321(-)

A ANBG-12LX

Strobe S0-2

Speaker V0-2 V

S

Backflow Preventer

VS

47k

Main - Fire Sprinkler System

SL

C

Lo op

A

B300-6

From

Device SLC Loop previous

Device SLC Loop To next

A

A

Addressable Smoke or Heat Detector

RA

F F F

V

S15C

4.7k

20k

Speaker/Strobe

Speaker

Strobe

VV

S S

Strobe

Strobe

S_ S_

D WF 47k

VS D

Main D PS

PS

LA

WF

47k

47k

S

S15C S15C

A

D

AIM

AIM D

A

T1

T2

T4 T5

LOOP

T6 T7 T8

T9 T10

ADDRESS

T3

T11

FMM-1

Fire Sprinkler Valve Tamper

D 0 15 14

6 7 8 9 9876

1 0

TENS ONES

A

A

Fire Sprinkler System - Valve Tamper with FMM-1 Monitor Module

F

To Fiber Network Bldg. 75

FTo Fiber Network Bldg. 77

15 1515

A

AIM

First Floor

Sub-Basement

First Floor

Sub-Basement

BasementBasement

Elevator Controls #1

120VAC Shunt Trip Power Source

Primary Recall (Steady) Alternate Recall (Steady)

Shunt Trip Breaker

Fire Light Indicator (Flashing)

R

FATCXP6-R

Sp ar e Sp ar e

47k

R D

A

AIM

Upper LevelUpper Level

Strobe S0-1

Speaker V0-1 V

S

S75

WP

S15

1W S75

4.7k

20k

V V

V

S S

VS

VS

AIM

AIM

D

D

PIV

D WFAIM

D WFAIM

VSAIM D

D WFAIM

VSAIM D

D WFAIM47k

47k

47k

47k

47k

47k

47k

47k

A

AIM

P S

F135°

AH

F

WP

VSAIM D 47k

VSAIM D 47k

A

P S

P S

P S

F135° H

F135° H

S75C S75C S30C S15C 15C

Strobe S0-3

Speaker V0-3 V

S

S30

S30 15 1W S75

1W S75

1W S75

15 15

15 S75C 1W S75

4.7k

20k

A

P S

P S

F135°

H AFF

P S

A

P S

P S

P S

V

S S S S

VV

AIM

47k

D

Security System Unlock Doors

AOM

R

Sound System

Shutdown

AOM

R

F

NCA

2AD,AP

SYSTEM INPUTS

PANEL FUNCTIONS

ALARM DEVICES

SYSTEM RESET

SYSTEM SILENCE

"ALL SYSTEMS NORMAL"

SMOKE DETECTORS

SUPERVISORY DEVICES

TROUBLE FUNCTIONS

ABNORMAL CIRCUIT OR DEVICE

FIRE ALARM SYSTEM AC POWER FAILURE

FIRE ALARM SYSTEM LOW BATTERY

SP

EA

KE

RS

A

ND

S

TR

OB

ES

S

TO

P

YE

LL

OW

LE

D W

IL

L F

LA

SH

A

ND

YE

LL

OW

LE

D W

IL

L F

LA

SH

A

ND

W

IL

L T

UR

N

ON

, U

NT

IL

S

IL

EN

CE

D.

RE

D

LE

D

AN

D

AU

IB

LE

S

OU

ND

ER

HI

ST

OR

Y

LO

G:

SYSTEM OUTPUTS

(S

YN

CH

RO

NI

ZE

D

AN

D

VO

IC

E

EV

AC

TE

MP

OR

AL

P

AT

TE

RN

AC

TI

VA

TE

S

BU

IL

DI

NG

S

IN

TE

RI

OR

N

OT

IF

IC

AT

IO

N

DE

VI

CE

S

REQUIRED FA CONTROLFACP FUNCTION

AC

TU

AT

ES

T

RO

UB

LE

C

ON

DI

TI

ON

A

T

CO

NT

RO

L P

AN

EL

PU

LS

IN

G

SO

UN

DE

R

W

IL

L T

UR

N

ON

, U

NT

IL

A

CK

NO

W

LE

DG

ED

AC

TU

AT

ES

S

UP

ER

VI

SO

RY

C

ON

DI

TI

ON

A

T

CO

NT

RO

L P

AN

EL

GR

EE

N

AC

P

OW

ER

IN

DI

CA

TO

R

IS

LI

T

ST

EA

DI

LY

ON

C

ON

TR

OL

P

AN

EL

CH

AR

AC

TE

R

LC

D

DI

SA

PL

Y

DI

SP

LA

Y

TH

E

CU

ST

OM

M

ES

SA

GE

"A

LL

S

YS

TE

MS

N

OR

MA

L"

AC

TU

AT

ES

A

LA

RM

C

ON

DI

TI

ON

A T

CO

NT

RO

L P

AN

EL

RE

CO

RD

IN

G

OF

T

HE

E

VE

NT

IN

S

YS

TE

MS

M

EM

OR

Y

PU

LS

IN

G

SO

UN

DE

R

W

IL

L T

UR

N

ON

, U

NT

IL

A

CK

NO

W

LE

DG

ED

FI

RE

A

LA

RM

C

ON

TR

OL

P

AN

EL

R

ET

UR

NS

T O

NO

RM

AL

NOTIFICATION

MANUAL PULL STATION

A B C D E F G H I J K L M N O P Q R

* FIRE SPRINKLER SYSTEM - ZONED WATERFLOW SWITCH (LATCHING)

FIRE SPRINKLER SYSTEM - MAIN WATERFLOW SWITCH (LATCHING)

Fire Alarm System Matrix

FIRE SPRINKLER SYSTEM - VALVE TAMPER SWITCH

MICROPHONE ACTIVATION WITH CIRCUIT SELECTION SWITCH

(C

ON

TA

CT

ID

) T

O U.

L.

CL

AS

S

CE

NT

RA

L S

TA

TI

ON

(C

ON

TA

CT

ID

) T

O U.

L.

CL

AS

S

CE

NT

RA

L S

TA

TI

ON

(C

ON

TA

CT

ID

) T

O U.

L.

CL

AS

S

CE

NT

RA

L S

TA

TI

ON

(C

ON

TA

CT

ID

) T

O U.

L.

CL

AS

S

CE

NT

RA

L S

TA

TI

ON

TR

AN

SM

IT

S W

AT

ER

FL

OW

C

ON

DI

TI

ON

V

IA

C

EL

LU

LA

R

CO

MM

UN

IC

AT

OR

TR

AN

SM

IT

S

TR

OU

BL

E

CO

ND

IT

IO

N

VI

A

CE

LL

UL

AR

C

OM

MU

NI

CA

TO

R

TR

AN

SM

IT

S

SU

PE

RV

IS

OR

Y

CO

ND

IT

IO

N

VI

A

CE

LL

UL

AR

C

OM

MU

NI

CA

TO

R

TR

AN

SM

IT

S

AL

AR

M

CO

ND

IT

IO

N

VI

A

CE

LL

UL

AR

C

OM

MU

NI

CA

TO

R

AN

NU

NC

IA

TO

RS

(B

OT

H

SP

EA

KE

RS

A

ND

S

TR

OB

ES

W

IL

L S

TO

P)

NO

TI

FI

CA

TI

ON

A

PP

LI

AN

CE

S

SH

AL

L B E

SI

LE

NC

EA

BL

E

AT

T

HE

FA

CP

O

R

- ELEVATOR LOBBY - (Basement)

- SPOT TYPE DETECTORS, (All, except as specifically noted below)

- ELEVATOR LOBBY - (First Floor)

- ELEVATOR MACHINE ROOM (Basement)

- TOP OF ELEVATOR SHAFT

EL

EV

AT

OR

R

EC

AL

L (

PR

IM

AR

Y)

EL

EV

AT

OR

R

EC

AL

L T

O

FI

RS

T

FL

OO

R

EL

EV

AT

OR

R

EC

AL

L (

AL

TE

RN

AT

E)

EL

EV

AT

OR

R

EC

AL

L T

O

BA

SE

ME

NT

AC

TI

VA

TE

E

LE

VA

TO

R

FI

RE

D

EP

AR

TM

EN

T

(F

LA

SH

IN

G) L

IG

HT

AC

TI

VA

TE

E

LE

VA

TO

R

FI

RE

D

EP

AR

TM

EN

T (S

TE

AD

Y) L

IG

HT

PR

IO

R

TO

S

PR

IN

KL

ER

H

EA

D

AC

TI

VA

TI

ON

SH

UT

DO

W

N

PO

W

ER

T O

AF

FE

CT

ED

E

LE

VA

TO

R

S

HEAT DETECTORS

- ELEVATOR MACHINE ROOM (Basement)

- BOTTOM OF ELEVATOR SHAFT

ON

YX

W

OR

KS

S

TA

TI

ON

IN

B

UI

LD

IN

G

SE

CU

RI

TY

O

FF

IC

E

TR

AN

SM

IT

S

SY

ST

EM

C

ON

DI

TI

ON

V

IA

FI

BE

R

NE

TW

OR

K

TO

T

- SPOT TYPE DETECTORS, (All, except as specifically noted below)

SE

CU

RE

D

DO

OR

S

SE

ND

S

IG

NA

L T

O

SE

CU

RI

TY

S

YS

TE

M

- U

NL

OC

K

AL

L

FIRE SPRINKLER SYSTEM - DRY SYSTEM - LOW AIR

DI

SP

LA

Y

AC

TI

VI

TY

O N

NE

TW

OR

K

AN

NU

NC

IA

TO

R

SE

ND

S

IG

NA

L T

O

SH

UT

DO

W N

AU

DI

TO

RI

UM

S

OU

ND

S

YS

TE

M

U

Number of Sheets:

By

Installing Fire Alarm System Contractor:

Date

Drawn By:

Drawn Date:

Scale:

Drawing No.

Revisions Description

Authority Having Jurisdiction:

Project Contacts

DHL

04/29/2024

VA

W al la

W al la

B ui ld in g

W ai nw rig ht

D riv e W al la

W al la , W

A

Li fe

S af et y

(F ire

A la rm S ys te m ) D ra w in gs

COPYRIGHT NOTICE

ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN

CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF

VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED

OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF

VULCAN FIRE

Reviewed by:

ENGINEERED SYSTEM DISTRIBUTION

by Honeywell

TM

Vulcan Project #: FI23-013

U .S

.D ep ar tm en t o f V et er an s A ffa irs

Fi re

A la rm S ys te m R ep la ce m en t -

P ha se B

Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362

(509) 524-4603

Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814

(208) 277-0171

GC

L ice ns e:

V

UL

CA

F*

0M

El ec

L ice ns e:

V

UL

CA

F*

W

EB

SI

TE

: w w w

.v ul ca nf ire us

.c om

PH

ON

E

(2

) 2

-0

Ea st H az el

A ve nu e, S ui te

1, C oe ur d 'A le ne

, I da ho

Record Drawings (04/23/2025)

1/8" = 1'-0"

FA-2.1

Riser Diagram / Details - Fire Alarm System

VOLTAGE DROPS ARE CALCULATED AT 16VDC.

L= ONE WAY LENGTH OF CIRCUIT(FEET)

WHERE VD= VOLTAGE DROP

R= 3.19 OHMS PER THOUSAND

I= LOAD CURRENT(AMPERES)

AFTER DETERMINING THE LENGTH OF THE HORN/STROBE CIRCUIT, USE

THE FOLLOWING FORMULA TO CALCULATE THE VOLTAGE DROP.

2xLxRxIVD=

LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD

ALLOWS FOR A SMALL MARGIN OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL

CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN ON THE SHOP SUBMITTAL

DRAWINGS. IF ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE

CIRCUIT LENGTH, CONTACT VULCAN FIRE.

VOLTAGE-DROP CALCULATION NOTE:

** STARTING VOLTAGE-DROP CALCULATIONS IS 20.4 PER UL 864, 9TH EDITION STANDARDS FOR FIRE ALARM

CONTROL PANELS.

AutoCAD SHX Text 47k

AutoCAD SHX Text

EOL

AutoCAD SHX Text Resistor

Sheets and Views
FI23-013 VA Walla Walla Bldg-78 FA_Record-FA-0.0 (1)
FI23-013 VA Walla Walla Bldg-78 FA_Record-FA-1.1 (2)
FI23-013 VA Walla Walla Bldg-78 FA_Record-FA-2.1 (3)

File details come from the government source that posted it. Updated .