FI23-013-VA-Walla-Walla-Bldg-143-FA_Record.pdf

PDF 7 MB Posted

Attached to
H212 Fire Alarm Inspections, Testing, Maintenance & Repairs - Walla Walla VA - Dept of Veterans Affairs
Solicitation number
36C26025Q0599
Issued by

About this file

These are fire alarm system record drawings for the U.S. Department of Veterans Affairs Medical Center in Walla Walla, Washington, specifically for Building 143. The comprehensive five-sheet set details a complete fire alarm system replacement project with Vulcan Fire as the design firm. The drawings cover a first and second floor fire alarm system plan, a riser diagram, system details, and a fire alarm system matrix.

The project involves replacing the existing campus fire alarm system with a new addressable Notifier fire alarm system, including new fiber optic cabling infrastructure, fire alarm control panels, and comprehensive device installations. Key system features include voice evacuation notification, HVAC unit and fire/smoke damper control, elevator recall functions, smoke and heat detector placements, manual pull stations, duct smoke detectors, and central monitoring capabilities. The project is designed to meet 2018 International Building Code, International Fire Code, and NFPA 72 standards, with the record drawings dated for completion on 5/9/2025.

View the file

Other files

File Type Posted
S06 Amendment 36C26025Q0599 0002.pdf PDF
S02 RFQ 36C26025Q0599_1 Rev 7-31-2025.pdf PDF
S06 Amendment 36C26025Q0599 0001.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-135-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-65-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-69-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-140-FA_RECORD.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-66-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-31-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-82-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-49-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-81-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-75-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-T1-and-T2-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-T-7-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-80-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-145-FA_Record.pdf PDF
S02 RFQ 36C26025Q0599_1.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-76-FA.pdf PDF
PP_Questionnaire.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-41-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-74-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-77-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-78-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-48-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-68-_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-63-FA_Record.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Number of Sheets:

By

Installing Fire Alarm System Contractor:

Date

Drawn By:

Drawn Date:

Scale:

Drawing No.

Revisions Description

Authority Having Jurisdiction:

Project Contacts

DHL

06/28/2024

VA

W al la

W al la

B ui ld in g

W ai nw rig ht

D riv e W al la

W al la , W

A

Li fe

S af et y

(F ire

A la rm S ys te m ) D ra w in gs

COPYRIGHT NOTICE

ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN

CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF

VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED

OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF

VULCAN FIRE

Reviewed by:

ENGINEERED SYSTEM DISTRIBUTION

by Honeywell

TM

Vulcan Project #: FI23-013

U .S

.D ep ar tm en t o f V et er an s A ffa irs

Fi re

A la rm S ys te m R ep la ce m en t -

P ha se B

Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362

(509) 524-4603

Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814

(208) 277-0171

GC

L ice ns e:

V

UL

CA

F*

0M

El ec

L ice ns e:

V

UL

CA

F*

W

EB

SI

TE

: w w w

.v ul ca nf ire us

.c om

PH

ON

E

(2

) 2

-0

Ea st H az el

A ve nu e, S ui te

1, C oe ur d 'A le ne

, I da ho

Record Drawings (5/9/2025)

N/A

FA-0.0

Site Plan

General Notes:

Drawing Notes:

Fire Alarm Control Panel Terminations:

Scope of Work:

All wiring runs shown on the fire alarm shop drawings are conceptual only. They do not and are not intended to be actual wire runs or conduit runs. Device interconnect is intended to show only sequence of device connections and type of wire.

Please review both the floor plans and the riser diagram drawings to resolve any conflicts or questions that may come up. If the drawings do not answer your questions, please call Vulcan Fire for help to answer your questions.

Electrical Contractor is advised not to complete terminations at the Fire Alarm Control Panel. Terminations will be completed by a qualified Vulcan Fire Technician.

Code Analysis:

Edition of Codes:

Number of Stories:

Edition of Standards:

Occupancy Type: B, Business (Clinic, Exam, Offices) S-1 Storage (Storage Closets)

2018 IBC, IFC, IMC

2018 NFPA 101

City of Walla Walla Amendments 2009 ANSI 117.1 Guidelines for Accessible & Useable

Yes, Fully Fire Sprinklered

2016 NFPA 72, 2020 NFPA 70 (NEC)

Visual Notification: Public Mode

Wire runs are indicated by AlphaNumeric designations.

power run of "2#__ " cable. A designation of "P3" would indicate another individual run of "2#__ " cable.

"2#__Twisted AND a run of 2#__ " cable.

A designation of "A,P2", would refer to a run of

The wire Gauge of any wire run is determined by the

A designation of "P2", would refer to a individual pair, 2#__ Twisted" cable.

A designation of "2A", would refer to a run of "2 length of the wire run and the power load on that run.

A typical wire run designated as "A", would refer to a single run of "2 #__ Twisted" cable.

For example:

A,P2

P2,P3

A

2A

Wire Chart:

Audible Notification: Voice Evac - Temporal 3 Pattern / Synchronized

Type of FA System: New Fire Alarm Addressable System

Index of Drawings Drawing Name

Drawing Number

Cover SheetCover SheetFA-0.0 FA-1.1 First Floor - Fire Alarm Plan

Temporal Pattern Notification Device Numbering:

(IE: HORN/STROBE)

AUDIBLE/VISUAL DEVICE

(IE: STROBE ONLY)

AUDIBLE DEVICE

(IE: HORN ONLY)

WITH THE REQUIREMENTS FOR VISUAL DEVICES.

1. ADA ACCESSIBILITY GUIDELINES HAVE ACCEPTED NFPA 72 GUIDELINES AS "EQUIVALENT FACILITATION".

3. MEASUREMENT IS TO THE BOTTOM OF THE DEVICE.

2. NFPA 72 STATES THAT COMBINATION AUDIBLE/VISUAL DEVICES SHALL BE MOUNTED IN ACCORDANCE

NOTES:

AFF = ABOVE FINISHED FLOOR0" (FLOOR)

NFPA 72

A

90" A.F.F.

A/V

96" A.F.F.

80" A.F.F.

NFPA 72

MAX.

MIN.

V

VISUAL DEVICE

CEILING

6" BELOW

CEILING

Example of Proper Mounting for Audible/Visual Devices:

Example of Junction Box Detail (FA):

If Applicable (Use for eample only)

Sheet Number

Walla Walla, WA 99362

U.S. Department Of Veterans Affairs VA Medical Center

77 Wainwright Drive

Owner

Fire Protection System:

Square Footage:

FA System Required: Code-Required

Project Manager: Dave Clem

GDM of Oregon 1584 McNeil Street, Suite 200

DuPont, WA 98327

Architect / Engineer

18,585 GSF

Protected Premises Fire Alarm Systems (Wiring):

Mounted Candela Rating:

S150 = 150 Candela S177 = 177 Candela S185 = 185 Candela

S135 = 135 Candela

S115 = 115 Candela S110 = 110 Candela S95 = 95 Candela S75 = 75 Candela S30 = 30 Candela S15 = 15 Candela

Ceiling S15C S15

Wattage Speaker 1W Tap

Guard WireWG WeatherproofWP

VOICE CIRCUIT

V 2

2S

POWER SUPPLY NUMBER

STROBE CIRCUIT

CIRCUIT NUMBER

AMPLIFIER NUMBER

CIRCUIT NUMBER

("T" Tap) Class B

Class B

P

F P

VS VSAIM

Class B

IDC - Initiating Device Circuit Manual Pull Stations, Fire Sprinkler System, Etc.

NAC - Notification Appliance Circuit Horns, Bells, Strobes, Etc.

SLC - Signaling Line Circuit Intelligent (Addressable) Devices

Only in J-Box (per Owner)

FS

S

Where used, End-Of-Line Resistors shall be labeled "EOL" on the Device (per Owner)

Building 143 77 Wainwright Drive, Walla Walla, WA 99362

Fire Alarm System Replacement

The scope of work for this project is to replace the existing campus fire alarm system with a new fire alarm system throughout. The existing copper cabling backbone infrastructure will be replaced with new fiber optic cabling. Each building will be provided with new fire alarm control panels connected to the campus network. A new campus wide computer monitoring and control system will be provided in Building 75.

Existing fire alarm devices such as pull stations, detectors, relay modules, monitor modules, flow and tamper switch interfaces, and associated conduit, boxes and cabling shall be demolished and replaced with new devices.

Building 143 Fire Alarm System:

The new Notifier fire alarm system in Building 143 will be replacing the existing fire alarm system. Voice evacuation notification appliances will be installed throughout the entire building, which will alert the occupants in the event of a fire. The FACP will provide control over the HVAC units and fire/smoke dampers and elevator recall function. The FACP will provide monitoring of the fire sprinkler system. Smoke and Heat Detectors will be installed where required per codes, in electrical and mechanical spaces, and as required to release magnetically held open doors. New manual pull station will be installed at building exits.

Duct smoke detectors will shutdown the associated HVAC units and smoke dampers. The duct smoke detectors and fire sprinkler tamper switches will cause a supervisory signal when activated. These devices will report as a supervisory signal.

The fire alarm system shall be monitored through a central monitoring company of the owners choosing prior to the final inspection.

FA-2.2 Load Calculations / Speaker Calculations / Fire Alarm Matrix

FA-2.1 Riser Diagram / Details4 FA-1.2 Second Floor - Fire Alarm Plan3

N

All intelligent and or addressable Fire Alarm Devices must be placed in protected areas with ambient temperature ranging from 32° to 120°. Weatherproof Fire Alarm Devices have temperature rating from -40° to 151° in wet or dry applications.

Do not place smoke detectors within 3 feet of air supply registers and diffusers.

All intelligent devices shall be interconnected as shown on the riser on-line diagram. Each intelligent device is designed with an address. T-Tapping is permitted on SLC Loop (Class "B") only.

Wire runs show interconnected of fire alarm devices only. Wiring does not represent conduit runs.

Electrical Contractor is responsible for proper connection of equipment provided by others.

(RL) Indicates Existing Device to be relocated to new location.

(R) Indicates Device to be removed and returned to Owner.

(E) Indicates Device existing to remain (shown in gray scale).

(N) Indicates New Device.

(RR) Indicates Remove Existing Device and replace with new Device. Return any removed equipment to Owner.

Setting Initiating Device Addresses:

D:L1: 501

ONESTENS

7 8 9

00 15

D = Detector M = Monitor

Device AddressData Loop Number

DIALS ARE

LOCATED ON THE

BACK OF EACH

DEVICE

Typical Device Mounting Height:

NFPA 2016

Wall Mounted AUDIBLE device.

Top of Individual Device

MAX

4'-0"

"ADA"

(48")

Top of Device of the Same Lens

Top of Unit

Top of Cabinet

To Handle of Device Per NFPA 72 from (AFF) Above All heights measured

NOT TO SCALE

Finished Floor

BOTTOM

OF

6'-0"

80" TO

MIN* (72")

LENS

See Note #5

7'-0"

TO TOP

OF

Approx.96"

MAX*

(84")LENS

(6")

THAN

BELOW

CEILING

(90")

AND

LESS

THAN

NOT

LESS

NOT

(64") 5'-4" or 80" MIN. to Bottom A/V or Visual Only Devices

MAX 96" to Top of Lens for all

#1) HEIGHTS SHOWN ARE LISTED IN NFPA STANDARDS 2016.

#2) MOUNTING HEIGHTS LISTED IN SPECIFICATIONS OR SHOWN ON THE

ARCHITECTURAL ELEVATIONS SHALL GOVERN. ANY DISCREPANCY SHALL BE

BROUGHT TO THE ATTENTION OF THE AHJ AND THE ENGINEER OF RECORD.

#3) WALL MOUNTED ADA STROBES & HORN/STROBES ARE TO BE PLACED

A MINIMUM OF 80" ABOVE FINISHED FLOOR MEASURED AT THE BOTTOM OF

THE LENS OR 6" BELOW THE CEILING TO THE TOP OF THE LENS,

WHICHEVER IS LOWEST. THE MAXIMUM HEIGHT MEASURED AT THE TOP OF

THE LENS SHALL NOT EXCEED 96".

#4) IN SLEEPING ROOMS A STROBE MOUNTED LESS THAN 24" FROM THE

CEILING SHALL BE AT LEAST 177CD. STROBES MOUNTED 24" OR BELOW

SHALL BE AT LEAST 110 CD. A STROBE SHALL BE MOUNTED WITHIN 16FT

OF THE PILLOW.

#5) REMOTE LIGHTS, TEST STATIONS AND MODULES SHOULD BE MOUNTED

SO AS TO BE ACCESSIBLE, YET ABOVE EASY REACH TO PREVENT

VANDALISM.

#6) CEILING MOUNT VISIBLE DEVICES SHALL BE SPACED ACCORDING TO

2016 NFPA 72.

FSA

FACFACP RPS

AIM AOM

F

RL

S15H15 15MC15

RT

J DM

MAP FTR

C

AOM

R

S

(48") 4'-0"

*MAX

(42") 3'-6"

*MIN

Obstructions or other Bends, 3 Feet x 6 = 18 Feet Duct Width = 3 Feet Example:

as far as possible Widths Maximum, or Minimum, 10 Duct Six Duct Widths

Inlet Return Air

Duct Smoke Detector Placement

Width

Width

The recommended location of Smoke Detectors mounted in or Duct Smoke Detectors mounted on air ducts should be between six duct widths and ten duct widths up stream from any duct openings, deflection plates, sharp bends, or branch connections. Refer to NFPA 72, 90A, 92A, OR 92B for further guidelines.

Duct Detectors shall be located:

A. At the Return Air Duct Side of AHU's above 2,000 CFM

Openings, as far as possible Widths Maximum, or Minimum, 10 Duct Six Duct Widths

Up to 1 ft.

Width

Outside Duct Recommended * Sampling Tube for different duct widths:

Sampling Tubes recommended

DST1

2/3 the duct width

* Must extend a minimum of

2 to 4 ft. DST3 4 to 8 ft. DST5 8 to 12 ft. DST10

1 to 2 ft. DST1.5

12" 1/4"

Detector

Duct

Sampling Tube 2"

The Sampling Tube should be angled at least 1/4" down for every 12" of duct width.

3/4" Hole

DST5

Sampling Tube Part Number

DST5

Downstream from Sampling Tube Exhaust Tube must be Mounted

Air Flow

Air Flow

Holes must Face into Air Flow

Detector

Detector

U.S. Department of Veterans Affairs

VA WALLA WALLA - FIRE LIFE SAFETY - PHASE B Fire Alarm Systems Interconnect Drawings

X

X X

X X

X

X

X

X

XX X

X

X

X

X

X

X

STATE NURSING HOME

STATE NURSING HOME

STATE NURSING HOME

STATE NURSING HOME

N U

R

SIN

G H

O M

E

FU

TU

R E

BL

D

G

7 49 48

66T-7

77T-1

T-2

756968

116119

121126125124

109CM

147 146

W

SITE

N1:

Node Number

FACP

MAP

RPS

EVAC

BATT

S P

F135°

VS

WF

AOM

R

R

RTS

S

AIM

F

S

S15C

S30C

S75C

SS

FARC

15C

C

Indicates Circuit Continuation Indicates Home Run to FACP

DH

AIM

M

FSA

AIM

D

S110

S135

S110

WP

15C

WP

ONYX

FATC #1

FATC #2/3

(E)

30C

APS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text PRV Vault

AutoCAD SHX Text F/A

AutoCAD SHX Text 8"

AutoCAD SHX Text Caps

AutoCAD SHX Text Tank

AutoCAD SHX Text Fuel

AutoCAD SHX Text F/A

AutoCAD SHX Text Valves

AutoCAD SHX Text

PRV

AutoCAD SHX Text F/A

To FACP

MAP

FSA

5 6 7 8 9 10 11 12 13

A

B

F

G

G.1

W

W

4' -0

Dedicated

120VAC

SS

FARC

MAP

To Bldg. Devices (SLC Loop)

CPU2-640

CLSS GATEWAY

HS-NCM-MF

NCA-2

DVC / CMIC-1

DAA2-7525 #1

DAA2-7525 #2 FACP

Spkr Crkts V0-1, V0-2, V0-3, V0-4, V0-5, V0-6 V1-1, V1-2, V1-3, V1-4

BATT

NAC Crkts X0-1, S0-2, S0-3, S0-4, RPS

To

RPS#2

NAC Crkts S1-1, S1-2, S1-3, S1-4, S1-5, S1-6

To Fiber Network Patch Panel

N1:L1:M021

P

P

P P P

P

P

P

P

P

Elevator Controls #1 (Field Verify Location)

120VAC Shunt Trip Power Source

Primary Recall (Steady) Alternate Recall (Steady)

Shunt Trip Breaker

Fire Light Indicator (Flashing)

FATCXP6-R #2

N1 :L

1:

M

N1 :L

1:

M

N1 :L

1:

M

N1 :L

1:

M

N1 :L

1:

M

N1 :L

1:

M

Sp ar e Sp ar e

N1:L1:M041

AIM

M

F135° H

F135° H

DH DH

F135° H

P

PF135°

H

143-TU1-123

To Smoke Dampers

120VAC AOM

R

R

N1:L1:M061

N1:L1:D061

RTS

S

143-TU1-122

To Smoke Dampers

120VAC AOM

R

R

N1:L1:M063 N1:L1:D063

RTS

S

F135° H

Elevator Controls #2 (Field Verify Location)

120VAC Shunt Trip Power Source

Primary Recall (Steady) Alternate Recall (Steady)

Shunt Trip Breaker

Fire Light Indicator (Flashing)

R

FATCXP6-R #3

N1 :L

1:

M

N1 :L

1:

M

N1 :L

1:

M

N1 :L

1:

M

N1 :L

1:

M

N1 :L

1:

M

Sp ar e Sp ar e

N1:L1:M031

AIM

M

AIM

Components located inside of

FACP

TELEHEALTH

PUBLIC TLT

PROV OFFICE

OFFICE

OFFICE

1213 1222

EXAM

HALLWAY

1299G

CLEAN STORAGE

1239A

EXAM

MULTI-PURPOSE

PROCEDURE

WOMEN'S

TOILET

WOMEN'S EXAM

WOMEN'S EXAM

TELE EXAM

EXAM

EXAM

EXAM

HAC

ST TLT

PAT TLT

1217A

ST TLT

BULK STOR

ADPAC

MAS SUPER.

OFFICE

HEALTH

TECHS

NURSE

WORKAREA

1299M

NURSE

WORKAREA

1299L

NURSE

WORKAREA

1299K

WAITING

1299N

WAITING

1299R

ELEVATOR P3

1199P-1

PAT TLT

PAT TLT

ST TLT

FAM TLT

1254A

SCALE

OFFICE

OFFICE

1288 OFFICE

PROV. OFFICE

PROV. OFFICE

CLINIC MGR

PROV OFFICE

PROV OFFICE

ROI CLERK

PAT TLT

PAT TLT

PAT TLT

1253A

GYN

PROCEDURE

PHARM D

PHARM D

SWITCHBOARD

OPERATOR

FOOT CLINIC

ISOL

EXAM

TELE EXAM

EXAM

EXAM

EXAM

EXAM

NURSE

CLINIC

MAS STOR

TELE

EXAM

EXAM

RESOURCE/ INFO

CENTER

FAM WAIT

RECEPTION

WAITING

1499C

HALLWAY

1499B

C&P STORAGE

AGENT CASH

OFFICE

BIO SAFETY

1412A

MICRO-

BIOLOGY

TLT/ SHWR

1505A

WCHAIR STOR

SPEC PROCESS

MECHANICAL

HOLTER

C & P CLERK

DEPLOY HEALTH

DEPLOY HEALTH

HALLWAY

1599D

VESTIBULE

1199A

STER

SOIL

PREP

PATH OFFICE

TLT/ SHWR

1501A

ELEVATOR

EQUIPMENT

1103A

SOUTH STAIR

1109-1

HALLWAY

1299H

ST TLT

COMM

C & P

EXAM

CLEAN

(ISO 7)

1311A

SECRETARY

HAC

ST TLT

HAC

SECURITY

COMM

ELEC

WAITING

1399A

SECURE

DISPENS

HALLWAY

1299F-1

HALLWAY

1299J

HALLWAY

1299C

HALLWAY

1599A

HALLWAY

1399D

EXAM

ELEVATOR P2

1199R

PURCHASING

ASSIST CHIEF

ANTE

HALLWAY

WCHAIR

SCALE

GAS STOR

Unoccupied

CONFERENCE

PROV OFFICE

PROV OFFICE

PROV OFFICE

STAFF CONF/

BREAK

LOCKERS

1601A

VESTIBULE

1199N

DIET

MST

OFFICE

TELE TRIAGE

OFFICE

SPEC

TLT

NORTH STAIR

1102-1

SLEEP

ROOM

TLT/ SHWR

1507A

SLEEP ROOM

SLEEP ROOM

TLT/SHWR

1503A

SLEEP ROOM

PUBLIC

CANTEEN

CORRIDOR

1199E

INTERVIEW

INTERVIEW

INTERVIEW

HALLWAY

1299A

CENTRAL

CHECK-IN

HALLWAY

1299B

BLOOD

DRAW

HALLWAY

1499A

CHIEF

SUPERV

CHIEF MED TECH

SECRETARY

CHEMISTRY/

HEMATOLOGY

COUNSEL

OFFICE

INVENTORY

CONTROL

1313A

HALLWAY

1399C

HALLWAY

1399B

BREAK DOWN

H A

LL

W

A Y

C

DME

1506A

CONTROL

C & P

EXAM

HEALTH TECHS

WAITING

1299Q

SOILED

HOLDING

1228A

WAITING

1299P

ELECTRICAL

MEDS

HALLWAY

1299E

HALLWAY

1299D

COFFEE SHOP

1101A

DISP OFFICE

1313D

HALLWAY

1599B

CLINIC RECEPT/

CLERKS

CORRIDOR

1199F

CORRIDOR

1199G

Unoccupied 1199H

PRESC. RECEIV.

OFFICE

1313C

VENDING

1101B

MAIN LOBBY

1199B

WCHAIR/

STRETCHER

STORAGE

URINALYSIS

ACTIVE & REFRIG

STORAGE

1313B

FILL &

ASSEMBLY

MAIL OUT

OFFICE

1313E

COUNSEL

OFFICE

BLOOD DRAW

ELEVATOR

EQUIP

OFFICE

OFFICE

BEHAVORIAL

HEALTH TECH &

EDU

NUT/ PAT ED

CLASS

TRAVEL CLERK

AGENT CASH

OFFICE

CLEAN / STERILE

STORAGE

TECH

OFFICE

OFFICE

1509A

PULMON

-ARY

TESTING

ELECTRICAL

1702A

PURCHASING

Unoccupied

TRAVEL CLERK

S15C

S30C

S15C

S15C

S15C

S15CS15C

S15C

S15CS15C

S15C

S15C

S15C

S15C

S15CS15CS15CS15C

S15C

S75CS15C

C

C C

C

C

C

C

S30C

S75C

S15C

C

S30C

S75C

S15C S75C

S15C

S75C

S30C S75C

S75C

S75C

C

S15C

S15C

S75C

S15C S15C

S15C

S15C

S15C

S75C

S75

S15C

S15C

S15C

S15C 15C

15C

S15C S30C

S15C

15C

15C

15C

15C

15C

15C

15C

15C

15C

15C

15C

15C

15C

15C

30C

15C

S30C

S30C

S15C

15C 30C

15C

15C 15C

15C

15C

15C15C 30C

15C

15C

15C

15C

15C

15C

15C

15C

15C

15C

S30C

WP

15C

WP

15C

S110C 1W

S110C 1W

S110 1W

WP

15C

WP

S110C 1W

S30CS75C

S75C

S15C

To RPS #1 & Annunciator

To

FACP

To

RPS

#1

15C

15C

15C

15C

15C

15C

15C

15C

15C

15C

15C

N1:L1:D001

F135° H5

N1:L1:M023

Security System Unlock Doors

AOM

R Field

Verify

N1:L1:D064

RTS

S

N1:L1:D062

RTS

S

N1:L1:D002

N1:L1:D003

N1:L1:D004

N1:L1:D005

N1:L1:D010

N1:L1:D011 N1:L1:D012

N1:L1:D013

N1:L1:D014

N1:L1:D015

N1:L1:D016

N1:L1:D017

N1:L1:D018

N1:L1:M001

N1:L1:M002 N1:L1:M003N1:L1:M004N1:L1:M005

N1:L1:M009

N1:L1:M011 N1:L1:M012

N1:L1:D021N1:L1:D022

N1:L1:D019

N1:L1:D020

15C

#1

X0-1 X0-1

S

S S S

S

S

S

S

S1-2 V0-2

S1-2 V0-2

S1-1 V0-1

S1-1 V0-1

S1-1 V0-1

S1-1 V0-1

S1-1 V0-1

S1-1 V0-1

S1-1 V0-1

S1-1 V0-1

S1-1 V0-1

S1-1 V0-1

S1-2

S1-1

S1-1

S1-2 V0-2

S1-2 V0-2

S1-2 V0-2

S1-2 V0-2

S1-6 V0-6

V0-2

S1-2 V0-2

S1-2 V0-2

S1-2 V0-2

S1-2 V0-2

S1-2 V0-2

S1-2 V0-2

S1-2 V0-2

S1-2 V0-2

S1-1 S1-1

S1-1 S1-1

S1-1

S1-1 S1-1

V0-1

V0-2

S1-3 V0-3

S1-3

S1-3

S1-3

S1-3 S1-3

S1-3

S1-3

S1-3 V0-3

S1-3 V0-3

S1-3 V0-3

S1-3 V0-3

S1-3 V0-3

S1-3 V0-3

S1-3

S1-3 V0-3

S1-3 V0-3

S1-3 V0-3

S1-4 V0-4

S1-4

S1-4

S1-4 V0-4

S1-4 V0-4

S1-4 V0-4

S1-4 V0-4

S1-4 V0-4

S1-4 V0-4

S1-4 V0-4

S1-4 V0-4

S1-4 V0-4

S1-4 V0-4

S1-4 V0-4

S1-4

S1-4

S1-4

S1-4

S1-4

S1-4

S1-4

S1-4

S1-5 V0-5

S1-5

S1-5

S1-5

S1-5

V0-5

S1-5 V0-5

S1-5 V0-5

S1-5 V0-5

S1-5 V0-5

S1-5 V0-5

S1-5 V0-5

S1-5

S1-5

S1-5

S1-5

S1-5

S1-5

S1-5

S1-5

S1-5

S1-5

S1-5S1-5

S1-5

S1-5

S1-6 V0-6

S1-6

S1-6

S1-6

S1-6

S1-6

S1-6S1-6

S1-6

S1-6 V0-6

V0-6

S1-6 V0-6

S1-6 V0-6

S1-6 V0-6

S1-6 V0-6

S1-6 V0-6

S1-6

S1-6 S1-6

S1-6

S1-6

S1-6

S1-6 S1-6

V0-6

V0-6 V0-5V0-5

S1-6

S1-6

R

R

To FSA #1 To ONYX

FATC #1 EVAC

N1:L1:M010

N1:L1:M008

MATCHLINE

MATCHLINE

15C S1-5

15C S1-2

Antenna Field Verify Exact Location

(E) (E)

S1-2

S1-2

15C S1-2

15C S1-2

15C 15C S1-1

15C S1-1

OFFICE

15C

S1-2 15C

S1-2 15C

15C S1-4

S1-4

15C S1-4

15C S1-5

15C S1-5

15C S1-5

15C S1-6

15C S1-6

N1:L1:M006

APS

120VAC

N1:L1:M067

AIM

To Magnetic Door Holders N1:L1:M066

AOM

C

Field Verify Exact Location

S1-4

S1-4

ONYX

L.I.U

ONYX

To RPS #1

To

RPS

#1

S

S

S S S

S

S

S

S

S

S

S

FF

F F

F

F F F

F

F

F

J

J

J

J

J

JJ

J

J

J

J

J

J

JJ

J

J J J J

J J

J

J

J J

J

J

J J

J

J

JJ

J

J

J

J

J

J

J

J

J JJ

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

JJ

J

J

J

J

J

J

J

J

J

J J J

J

J

J

J

J

J J

J

J

J

J

JJ

J

J

J

J J

JJ

J

JJ

J

J

J

J

J

J

J

JJ J

J

J

J

J J

J

J

J

J J

J

J

J

J

J J

J

J

J J

J

J J J J

J

J J

J

J

J J

J

J

J

J

S

2AD,AP

EP

A XX

F

D

D

RT

RT

D

2S

2S

2S

2S

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V S,V

S,V

S,V

S,V

2S

2S

S,V

S,V

S,V

S,V

S,V

S,V S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V S,V

S,V

S,V

S,VS,V

2S

2S

2S

S,V

2S

S,V

S,V

S,V

S

S,VS,VS,VS,V

S,V

S,V

S,V

RT

RT

S,V

AD,AP

F

S,V

S,V

S,V

S,V

2S

S,V S,V

S,V

EP

D

P 2P

2S

2S

2S

F

P

F

F

2S

2S 2S

2S

2S

2S

2S

2S

2S

2S

2S

2S

2S

2S 2S

2S

2S

2S

2S

2S

2S

2S

2S

2S

2S

2S

2S

2S

2S

2S

2S

2S

2V

2S

S,V

S,V

2S

2S

2S

2S

2S

2S

2S

2S

2S

2S

2S 2S

S,V

S,V

S,V

2S

2S

2S

2S

S,V

S,V

S,V

S,V 2S,2V

S,V

S,V

S,V

S,V

A

A

A

A

A

AA

A

A

A

A

A

A A

A A

A

A

A

A

A 2S,2V A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

AA

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A A

A

A

A

A A

A

A

AD,AP

S,V

S,V

A

A

A

P

P P P P P P

2V

General Note:

Addressing Legend:

D = Detector M = Module

Module/Device Number M01L01

Loop Number

* All addressable devices require SLC Loop (A-wire) from the FACP to operate. For help, please refer to riser diagram for reference.

* Do not route conduit into the bottom of any fire alarm system component cabinets.

* After each duct smoke detector has been installed use a Megnehelic Test Instrument to verify adequate air flow, show the results on the Shop Drawings for the AHJ's review.

* Tap all speakers at 1/2 watt - 25 volts unless otherwise indicated at individual device.

* Contractor may reuse existing pathways where available. Verify with system designer prior to adding additional devices or extending circuits to ensure voltage drop calculations are within acceptable limits.

S75C

C

N1:L1:M007

S

S1-2 V0-2

MATCHLINE

MATCHLINE

F

J

J

S,V

S,V A

A

A

1) Section of NFPA 72, National Fire Alarm Code requires units to be provided with smoke detection in areas that are not continuously occupied.

2) Provide Dedicated 120VAC circuit to the FACP label the Dedicated circuit breaker "Fire Alarm." In red with lockout. Location of breaker shall be noted at FACP.

3) Detector is provided for Smoke Damper Activation.

4) Detector is to activate Elevator Recall Functions.

5) Detector is to activate Elevator Shunt Trip. Mount within 24" of Sprinkler

Head.

6) Detector is to activate Door Release Service (Magnetic Door Hold Opens).

7) Fiber Network routing to be field coordinated.

Flag Notes: (Some flag notes may not appear on every sheet)

Number of Sheets:

By

Installing Fire Alarm System Contractor:

Date

Drawn By:

Drawn Date:

Scale:

Drawing No.

Revisions Description

Authority Having Jurisdiction:

Project Contacts

DHL

06/28/2024

VA

W al la

W al la

B ui ld in g

W ai nw rig ht

D riv e W al la

W al la , W

A

Li fe

S af et y

(F ire

A la rm S ys te m ) D ra w in gs

COPYRIGHT NOTICE

ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN

CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF

VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED

OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF

VULCAN FIRE

Reviewed by:

ENGINEERED SYSTEM DISTRIBUTION

by Honeywell

TM

Vulcan Project #: FI23-013

U .S

.D ep ar tm en t o f V et er an s A ffa irs

Fi re

A la rm S ys te m R ep la ce m en t -

P ha se B

Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362

(509) 524-4603

Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814

(208) 277-0171

GC

L ice ns e:

V

UL

CA

F*

0M

El ec

L ice ns e:

V

UL

CA

F*

W

EB

SI

TE

: w w w

.v ul ca nf ire us

.c om

PH

ON

E

(2

) 2

-0

Ea st H az el

A ve nu e, S ui te

1, C oe ur d 'A le ne

, I da ho

Record Drawings (5/9/2025)

1/8" = 1'-0"

FA-1.1

Scale: 1/8'' = 1'-0''

20 4 8 16 32

First Floor - Fire Alarm System Plan

Scale: 1/8'' = 1'-0''

20 4 8 16 32

First Floor - Fire Alarm System Plan (Cont.)

AutoCAD SHX Text

HEAD

AutoCAD SHX Text

HEAD

AutoCAD SHX Text

HEAD

AutoCAD SHX Text

HEAD

AutoCAD SHX Text

KIOSK WALL MOUNT

AutoCAD SHX Text

KIOSK WALL MOUNT

AutoCAD SHX Text

KIOSK FREE STANDING

AutoCAD SHX Text

KIOSK FREE STANDING

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

FILE

5 6 7 8 9 10 11 12 13

A

B

C

D

E

F

G

D.7

D.3

G.1

P

P

DH

DH

DH

DH

P

P

P

P

NAC & Speaker Control / Sync

EP

NAC Crkts S2-1, S2-2, S2-3, S2-4, S2-5, S2-6, RPS

120VAC

XTo RPS#1

D N1:L1:M022

AIM

P

F135°

P

P

OPC-AHU-2 OPC-AHU-1

P

F135°

P

F135°

RECREATION

THERAPY

STOR

2201A RECREATIONAL

KITCHEN

HALLWAY

2299D

DAY COUNS

OFFICE

DAY COUNS

OFFICE

COUNS OFFICE

COUNS OFFICE

COUNS OFFICE

COUNS OFFICE

COUNS OFFICE

COUNS OFFICE

COUNS OFFICE

COUNS OFFICE

COUNS OFFICE

COUNS OFFICE

COUNS OFFICE

HALLWAY

2299D

STORAGE

ANTE-COAG

OFFICE

PATIENT

TESTING

STAFF BREAK

ADMIN OFFICE

ST LKR / TLT

SHWR

2108A

SHWR

2109A

ST LKR / TLT

HAC

C O

R R

ID

O

R

F

PSYCH OFFICE

ANTE-COAG

OFFICE

REHAB COUNS

OFFICE

REHAB COUNS

OFFICE

REHAB COUNS

OFFICE

REHAB COUNS

OFFICE

REHAB COUNS

OFFICE

REHAB COUNS

OFFICE

STAT CLERK

RECEPT

HALLWAY

2299B

STORAGE

GROUP

THERAPY

ROOM

GROUP

THERAPY

ROOM

CCHT

CCHT

HAC STORAGE

2103A

NORTH STAIR

1102-2

Unoccupied

1199DB

Unoccupied

1199EC

CORRIDOR

2199A

WAITING

2299A

SOUTH STAIR

1109-2

ELEVATOR P3

1199P-2

PAT. TLT.

2402 PAT. TLT.

2404A

PRE - POST

OP

PRE - POST OP

MECHANICAL

PRE -

POST OP

PRE - POST OP

SOIL HOLD

ENDO/ MINOR

SURG

SCOPE CLEAN

2416A

ANTE ROOM

CYSTO

HAC

PAT TLT

2420B

RAD-FILM

PROCESS

2420A

ENDO/ MINOR

SURG

EQUIP & APPAR

STOR

INFUSION

MGR. OFFICE

PHYSICIANS

OFFICE

PHYSICIANS

OFFICE

EXAM ROOM

OT EQUIP STOR

LOCKERS

WAITING

2499A

RECEPTION

ST TLT/SHWR

2423A

CLEAN/ STERILE

STOR.

TELE EXAM

ROOM

EXAM ROOM

EXAM ROOM

MINOR

PROCEEDURE

PT EXERCISE

PUB TLT

PUB TLT

PT OFFICE

CHIEF TECH

OFFICE

HALLWAY

2399C

OT OFFICE

WAITING

2399A

COMM

ELECTRICAL

HALLWAY

2399D

ST TLT

ALCOVE

EXAM ROOM

EXAM ROOM

UTILITY

HALLWAY

2499D

HALLWAY

2499E

HALLWAY

2499F

HALLWAY

2499G

NURSE STATION

MED.

ROOM

OT TREATMENT /

ADL EVAL

CORRIDOR

2199E

EDUCATION

DH DH

S15C

S15C

S15C

S75C

S75CC C

C

S15C

S15C

C

S15CS15C C

S30C

S15C

S15C

S15C

S75C

S15C

S15C

S15C

S15C

C

C

S30C

S75C

S15CS30C

S15C

S30C

C

S30C

S75C

S15C

S135

S15C

S75C

S15C S15C S15C

S75C

15C

15C

15C

15C 15C

15C 15C

15C

15C

15C

15C

15C

WP

15C

15C

15C15C

15C

15C

15C

15C

S110

WP

S110

WP

S110

WP

S110

WP

S15C

Fed From Bottom of Shaft

2'X2' J-BOX Home Runs from 1st Floor.

Voice, SLC, 24V DH

(S) To

RPS#2

15C

S30C

N1:L1:M014

N1:L1:M016

N1:L1:M017

N1:L1:D032

N1:L1:D033

N1:L1:D034

N1:L1:D035

N1:L1:D037

N1:L1:D036

N1:L1:D038

N1:L1:D039N1:L1:D040

N1:L1:D041

N1:L1:D042

N1:L1:D043

#2

X0-1

S2-2 V1-2

S2-1 V1-1

S2-2 V1-2

S2-2 V1-2

S2-2

S2-2 V1-2

S2-2 V1-2

S2-2 V1-2

S2-2 V1-2

S2-2 V1-2

S2-2 V1-2

S2-2 V1-2

S2-2 V1-2

S2-2 V1-2

S2-2 V1-2

S2-3 V1-3

S2-3 V1-3

S2-3 V1-3

S2-3 V1-3

S2-3 V1-3 S2-3

V1-3

S2-3 V1-3

S2-3 V1-3

S2-4 V1-4

S2-4 V1-4

S2-4 V1-4

S2-4 V1-4

S2-4 V1-4

S2-4 V1-4

S2-4 V1-4

S2-1 V1-1

S2-1 V1-1

S2-1 V1-1

S2-1 V1-1

S2-1 V1-1

S2-1 V1-1

S2-1 V1-1

S2-1 V1-1

V1-1

V1-4

V1-4

S2-4 S2-4

S2-4S2-4

S2-4

S2-4

S2-4

S2-4

S2-4

S2-4

S2-4

S2-4

S2-4

S2-4

S2-3

S2-3 V1-3

S2-3 V1-3

V1-3

V1-3

V1-3

V1-2

V1-2

S2-2

S2-2

S2-2

S2-3 S2-3S2-3

S2-1S2-1 S2-1

S2-1

S2-1

S2-1

S2-1

S2-1

S2-1 V1-1

To Smoke Dampers

120VAC AOM

R

R

N1:L1:M065 N1:L1:D065

RT

RTS

S

N1:L1:D066

RT

RTS

S

MATCHLINE

MATCHLINE

S2-4

(E)

(E)

15C S2-4

15C S2-1

N1:L1:M013

(E) (E)

15C S2-2

S2-2 15C

S2-2

15C S2-2

15C S2-3

VFD

P

N1:L1:D044

N1:L1:D065

RT

RTS

S

Module:

L1:M063

N1:L1:D066

RT

RTS

S

Module:

L1:M066

N1:L1:D067

RT

RTS

S

Module:

L1:M064

P

N1:L1:D031

Fed From Bottom of Shaft

P

N1:L1:D062

RT

RTS

S

Module:

L1:M061

N1:L1:D064

RT

RTS

S

Module:

L1:M062

S135 S2-4 V1-4

L1:M073

VFD

L1:M074

SLC Fed From

RM 1525

VFD

L1:M071

VFD

L1:M072

L1:M052 - Tamper West L1:M051 - Tamper East

L1:M049 - WF West L1:M047 - WF East

Fed From Downstairs

N1:L1:D046

N1:L1:D045

N1:L1:D061

RT

RTS

S

(V) To

FACP

S2-4

S75 S2-3 V1-3

S2-3 V1-3 S75

J

J

J

J

J J

J

J J

J

J

J

J

J

J

J

J

JJ

J

J

J

J

J

J J

J

J

J

J J

J

J

J

J J

J J

J

J J J

J

J

J

JJJJJ

J

J

J

J

J

J

J

J

J

J

J

J

J

JJ J J J J

J

J

J

J

J J

J J

J

J

J

J J J

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

F

F

F

F

A

H

H

H

A A

A

A

A

A

A

A

A

A

A A A A

A

A

A

A

A

A A A

A

A

A

P

P

P

P P

P

P

P

P

P

P

P

P

P

P

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V S,V

S,V

S,V

S,V

S,V

S,V S,V S,V

S,V

S,V

S,V

S,V

S,V

S,VS,V

S,V

S,V

S,V

S,V

S,V S,V

S,V

S,V S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,VS,V

S,V

S,V

S,VS,V

S,V

S,V

S,V

S,V

S,V

J

S,V

S,V

S,V

S,V

S,V

S,V S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,VS,V

A

S,VS,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,VS,V

S,V

S75C

C

N1:L1:M015

S2-1 V1-1

V1-1

MATCHLINE

MATCHLINE

J

J

J

S

F A

A

A

A

S,V

S,V

S,V

S,V

General Note:

Addressing Legend:

D = Detector M = Module

Module/Device Number M01L01

Loop Number

* All addressable devices require SLC Loop (A-wire) from the FACP to operate. For help, please refer to riser diagram for reference.

* Do not route conduit into the bottom of any fire alarm system component cabinets.

* After each duct smoke detector has been installed use a Megnehelic Test Instrument to verify adequate air flow, show the results on the Shop Drawings for the AHJ's review.

* Tap all speakers at 1/2 watt - 25 volts unless otherwise indicated at individual device.

* Contractor may reuse existing pathways where available. Verify with system designer prior to adding additional devices or extending circuits to ensure voltage drop calculations are within acceptable limits.

1) Section of NFPA 72, National Fire Alarm Code requires units to be provided with smoke detection in areas that are not continuously occupied.

2) Provide Dedicated 120VAC circuit to the FACP label the Dedicated circuit breaker "Fire Alarm." In red with lockout. Location of breaker shall be noted at FACP.

3) Detector is provided for Smoke Damper Activation.

4) Detector is to activate Elevator Recall Functions.

5) Detector is to activate Elevator Shunt Trip. Mount within 24" of Sprinkler

Head.

6) Detector is to activate Door Release Service (Magnetic Door Hold Opens).

7) Fiber Network routing to be field coordinated.

Flag Notes: (Some flag notes may not appear on every sheet)

Number of Sheets:

By

Installing Fire Alarm System Contractor:

Date

Drawn By:

Drawn Date:

Scale:

Drawing No.

Revisions Description

Authority Having Jurisdiction:

Project Contacts

DHL

06/28/2024

VA

W al la

W al la

B ui ld in g

W ai nw rig ht

D riv e W al la

W al la , W

A

Li fe

S af et y

(F ire

A la rm S ys te m ) D ra w in gs

COPYRIGHT NOTICE

ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN

CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF

VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED

OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF

VULCAN FIRE

Reviewed by:

ENGINEERED SYSTEM DISTRIBUTION

by Honeywell

TM

Vulcan Project #: FI23-013

U .S

.D ep ar tm en t o f V et er an s A ffa irs

Fi re

A la rm S ys te m R ep la ce m en t -

P ha se B

Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362

(509) 524-4603

Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814

(208) 277-0171

GC

L ice ns e:

V

UL

CA

F*

0M

El ec

L ice ns e:

V

UL

CA

F*

W

EB

SI

TE

: w w w

.v ul ca nf ire us

.c om

PH

ON

E

(2

) 2

-0

Ea st H az el

A ve nu e, S ui te

1, C oe ur d 'A le ne

, I da ho

Record Drawings (5/9/2025)

1/8" = 1'-0"

FA-1.2

Scale: 1/8'' = 1'-0''

20 4 8 16 32

Second Floor - Fire Alarm System Plan

Scale: 1/8'' = 1'-0''

20 4 8 16 32

Second Floor - Fire Alarm System Plan (Cont.)

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

WS 24 X 30

AutoCAD SHX Text

WS 24 X 30

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 48

AutoCAD SHX Text

WORK SURF 24 X 48

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

WORK SURF 24 X 24

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

2 DR 30" LATERAL

AutoCAD SHX Text

2 DR 30" LATERAL

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

2 DR 30" LATERAL

AutoCAD SHX Text

BOOKWCASE 4 HIGH

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

2 DR 30" LATERAL

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

BOOKWCASE 4 HIGH

AutoCAD SHX Text

BOOKWCASE 4 HIGH

AutoCAD SHX Text

BOOKWCASE 4 HIGH

AutoCAD SHX Text

WORK SURF 24 X 36

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

WS 24 X 30

AutoCAD SHX Text

4 DR LATERAL

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

BOOKWCASE 4 HIGH

AutoCAD SHX Text

BOOKWCASE 4 HIGH

AutoCAD SHX Text

BOOKWCASE 4 HIGH

AutoCAD SHX Text

BOOKWCASE 4 HIGH

AutoCAD SHX Text

BOOKWCASE 4 HIGH

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

BOOKWCASE 4 HIGH

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text

4 DR LATERAL

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

PED

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

HUTCH 4' W/DOOR

AutoCAD SHX Text

PED BOX BOX FILE

AutoCAD SHX Text

BOOKWCASE 4 HIGH

AutoCAD SHX Text

2 DR 36" LATERAL

AutoCAD SHX Text 3'-6"

AutoCAD SHX Text

KIOSK TABLETOP

AutoCAD SHX Text

KIOSK FREE STANDING

AutoCAD SHX Text

KIOSK FREE STANDING

AutoCAD SHX Text

KIOSK FREE STANDING

AutoCAD SHX Text

KIOSK WALL MOUNT

KIOSK FREE STANDING

First Floor First Floor

Second Floor Second Floor

Dedicated

120VAC

SS

FACP

FARC

MAP

GUTTER

CPU2-640

HS-NCM-SF

CLSS GATEWAY

NCA-2

DVC / CMIC-1

DAA2-7525 #1

DAA2-7525 #2

FSA

MAP EVAC

BATT

Battery Battery

FSA

MAP

Addressable Pull Station

321(-)

A ANBG-12LX

S15C S75C

Backflow Preventer

VS

47kWaterflow

0 15 14

6 7 8 9 9876

1 0

FDM-1

T1

T2

T4

T5

LOOP

T6

T7

T8

T9

T10

TENS ONES

ADDRESS

T3

T11

Fire Sprinkler System - Waterflow Switch with FDM-1 Dual Monitor Module

A

A

D

D

Main - Fire Sprinkler System

PPPPP

AIM

D B300-6

From

Device SLC Loop previous

Device SLC Loop To next

A

A

Addressable Smoke or Heat Detector

RA

Security System Unlock Doors

AOM

R

AIM

D

Second Floor

WF

VS 47k

47k

AIM

D

First Floor

WF

VS 47k

47k

PPPPPP

RPS

#1

Battery Battery

S30C S75C

S15C S15C

S15C S30C

S15C

S15C S15C

RPS

#2

Battery Battery

2.2k S30C S30C

S15C S30C

S15C S75C

120VAC

(H)(N)

ADDRESS

LOOP

Yellow

Violet

0 15 14

TENS

5 11

7 8 9

ONES

Red

1 0

Black

Shunt Trip

Shunt Trip Power Monitored by FMM-101

AA

D

Elevator Controls #2 (Field Verify Location)

120VAC Shunt Trip Power Source

Primary Recall (Steady) Alternate Recall (Steady)

Shunt Trip Breaker

Fire Light Indicator (Flashing)

R

FATCXP6-R #3

Sp ar e Sp ar e

N1:L1:M009AIM

M

Elevator Controls #1 (Field Verify Location)

120VAC Shunt Trip Power Source

Primary Recall (Steady) Alternate Recall (Steady)

Shunt Trip Breaker

Fire Light Indicator (Flashing)

R

FATCXP6-R #2

Sp ar e Sp ar e

N1:L1:M009AIM

M

F135° H

F135° H

F135° H

F135° H

F135° H

RTS

S

To F/S Dampers

120VAC

R

AOM

R

RTS

S

RTS

S

To F/S Dampers

120VAC

R

AOM

R

RTS

S

AIM

47k47k

47k

AIM

47k

T1

T2

T4 T5

LOOP

T6 T7 T8

T9 T10

ADDRESS

T3

T11

RPS Monitored by a FMM-1 Monitor Module

FMM-1

Remote Power Supply (Trouble)

D 0 15 14

6 7 8 9 9876

1 0

TENS ONES

A

A

(N) (H)12

0V

AC

PR-1

F/S Damper or Magnetic Door Hold Opens

0 15

6 7 8 9 9876

1 0

T1

T2

T4 T5

LOOP

T6 T7 T8

T9 T10

TENS ONES

ADDRESS

T3

T11

FRM-1

A

A

F/S Dampers with R-10E Relay Controlled by FRM-1 Control Relay Module

S15C S15C S75C 15C 15C 15C 15C S75C S15C S75C S75C S30C S75C 75 15 15 15 S75C

4.7k

20kS

S75C

C S

S15C S15C S30C S75C

C S

S75C S15C S15C S30C S15C

C

S75C

S

4.7k

20k

1W

S110WP

15C S15C 1W

S110WP

15C

1W S110S15C S30C S75C S75C

4.7k

20k

1W S110

S15C S30C S15C S15C S30C S15C S15C S30C S15C S15C

4.7k

20k

C S

S15C S15C

S

S15C S15C 15C S15C

C S

C

S15C

20k

4.7k

S15C

C S

S15C S15C S15C S15C

S C

S15C S15C

4.7k

20k

Speaker/Strobe

Speaker

Strobe

VV

S S

Strobe

Strobe

S_ S_

R R

S30C

C S

S15C S75C S30C S15C S30C 15 15S15C S15C S75C

C S

4.7k

20k

S75C 30 S15C S15C S75C S15C S15C S15C

C S

S15C

C S

S75C

WP

S110

WP

S110

4.7k

20k

S15C

WP

S110

WP

S110 S15C

C S

S15C S15C S15C

C S

S75C S75C S75C

C S 20k

4.7k

S15C S15C

S C

S C

S15C S15C S75C S15C S135 S135

4.7k

20k

5.6K

TEST COIL (+)

TEST COIL (-)

COMM(+)

OUT CONV ONLY (+)

COMM (-)

RA/RTS (-)

RA (+)

RTS (+)

From previous SLC Loop

Devices

To next SLC Loop Devices(+)

RTS-151KEY

REMOTE

TEST

STATION

JUMPER

Duct Smoke Detector with Remote Test Station RTS-151

A

RT

RTS

To F/S Dampers

120VAC

R

AOM

R

RTS

P PPPPP PPPPP

F135° H

F135° H

S S

Shutdown To Fan

0 15

6 7 8 9 9876

1 0

T1

T2

T4 T5

LOOP

T6 T7 T8

T9 T10

TENS ONES

ADDRESS

T3

T11

FRM-1

*Verify Connection with Mech. HVAC Contractor

A

A

Fan Shutdown Controlled by FRM-1 Control Relay Module

AHU-2

To Fan

Shutdown

AOM

R

RTS

S

AHU-2 AHU-1

To Fan

Shutdown

AOM

R

RTS

S

AHU-1

4.7k

4.7k

ONYX

To Fiber

Network Patch Panel

WF 47k

VS

Main

YE

LL

OW

NC

BL

UE

C

OR

AN

GE

NO

FATC #1

Antenna

Field Verify Exact

Location

To Fiber Network Patch Panel

15C 15C 15C

15C 15C 15C 15C 15C 15C 15C

15C 15C 15C

WP

15C

WP

15C 15C

15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C

15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C

15C 15C 15C 15C 15C 15C 15C 15C 15C 30C

C S

15C 15C 15C 15C 15C 15C 15C 15C 15C 30C

15C 15C 15C 15C 15C 15C 15C

15C 15C 15C 15C 15C 15C 15C

15C 15C 15C 15C 15C

15C

WP

15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C 15C

C P

F135° H

F135° H

T1

T2

T4 T5

LOOP

T6 T7 T8

T9 T10

ADDRESS

T3

T11

Door Control by a FCM-1 Control Module

FCM-1

X 0 15 14

6 7 8 9 9876

1 0

TENS ONES

A

A

P

24V

OUTPUT

24V

INPUT

APS

Battery Battery

47k

AOM

C

DH(E)

DH(E)

DH(E)

DH(E)

DH(E)

DH(E)

DH(E)

DH(E)

AIM

47k

SSSSS SSSSSS

S SSSSS SSSSS

S

F F F F F F F F F F

FF F F F

FF

EP

AD,AP

AD

Strobe S1-1

Speaker V0-1 V

S

SL

C

Lo op

A

AA

D

D

D

DA

A

Dedicated

120VAC

EP

Sy nc

C kt

X

0-

X

Strobe S1-2

Speaker V0-2 V

S

Strobe S1-3

Speaker V0-3 V

S

Strobe S1-4

Speaker V0-4 V

S

Strobe S1-5

Speaker V0-5 V

S

Strobe S1-6

Speaker V0-6 V

S

V V

V V

V V

V V

V V

Dedicated

120VAC

EP

X

X0-1

Strobe S2-1

Speaker V1-1 V

S

Strobe S2-2

Speaker V1-2 V

S

Strobe S2-3

Speaker V1-3 V

S

Strobe S2-4

Speaker V1-4 V

S

DD

A

A

RT RT RT RT

D

D

A

A

A

A

A

RT RT

A

A

A

A

A

A

RT RT

AD,AP

AD

F

A

A

X

D

D

D

AA

A 6V

F

F

2P

Dedicated

120VAC

EP

P

P

P

P

P

P

P

P

D

Number of Sheets:

By

Installing Fire Alarm System Contractor:

Date

Drawn By:

Drawn Date:

Scale:

Drawing No.

Revisions Description

Authority Having Jurisdiction:

Project Contacts

DHL

06/28/2024

VA

W al la

W al la

B ui ld in g

W ai nw rig ht

D riv e W al la

W al la , W

A

Li fe

S af et y

(F ire

A la rm S ys te m ) D ra w in gs

COPYRIGHT NOTICE

ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN

CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF

VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED

OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF

VULCAN FIRE

Reviewed by:

ENGINEERED SYSTEM DISTRIBUTION

by Honeywell

TM

Vulcan Project #: FI23-013

U .S

.D ep ar tm en t o f V et er an s A ffa irs

Fi re

A la rm S ys te m R ep la ce m en t -

P ha se B

Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362

(509) 524-4603

Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814

(208) 277-0171

GC

L ice ns e:

V

UL

CA

F*

0M

El ec

L ice ns e:

V

UL

CA

F*

W

EB

SI

TE

: w w w

.v ul ca nf ire us

.c om

PH

ON

E

(2

) 2

-0

Ea st H az el

A ve nu e, S ui te

1, C oe ur d 'A le ne

, I da ho

Record Drawings (5/9/2025)

N/A

FA-2.1

Riser Diagram / Details - Fire Alarm System

AutoCAD SHX Text 47k EOL RESISTOR

AutoCAD SHX Text 47k EOL RESISTOR

AutoCAD SHX Text

47K EOL RESISTOR

AutoCAD SHX Text

NO

AutoCAD SHX Text C

AutoCAD SHX Text

NC

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 47k

AutoCAD SHX Text

EOL

AutoCAD SHX Text Resistor

AutoCAD SHX Text 47k

AutoCAD SHX Text

EOL

Resistor

- ELEVATOR LOBBY - (First Floor)

SYSTEM INPUTS

PANEL FUNCTIONS

ALARM DEVICES

SYSTEM RESET

SYSTEM SILENCE

"ALL SYSTEMS NORMAL"

SMOKE DETECTORS

SUPERVISORY DEVICES

TROUBLE FUNCTIONS

ABNORMAL CIRCUIT OR DEVICE

FIRE ALARM SYSTEM AC POWER FAILURE

FIRE ALARM SYSTEM LOW BATTERY

- SPOT TYPE DETECTORS, (All, except as specifically noted below)

EL

EV

AT

OR

R

EC

AL

L (

PR

IM

AR

Y)

SP

EA

KE

RS

A

ND

S

TR

OB

ES

S

TO

P

YE

LL

OW

LE

D W

IL

L F

LA

SH

A

ND

YE

LL

OW

LE

D W

IL

L F

LA

SH

A

ND

W

IL

L T

UR

N

ON

, U

NT

IL

S

IL

EN

CE

D.

RE

D

LE

D

AN

D

AU

IB

LE

S

OU

ND

ER

HI

ST

OR

Y

LO

G:

SYSTEM OUTPUTS

EL

EV

AT

OR

R

EC

AL

L T

O

SE

CO

ND

FL

OO

R

EL

EV

AT

OR

R

EC

AL

L (

AL

TE

RN

AT

E)

EL

EV

AT

OR

R

EC

AL

L T

O

FI

RS

T

FL

OO

R

LO

CA

TE

D

AB

OV

E

FI

RE

D

EP

AR

TM

EN

T

CO

NN

EC

TI

ON

AC

TI

VA

TE

S

BU

IL

DI

NG

S

EX

TE

RI

OR

N

OT

IF

IC

AT

IO

N

DE

VI

CE

(S

YN

CH

RO

NI

ZE

D

AN

D

VO

IC

E

EV

AC

TE

MP

OR

AL

P

AT

TE

RN

AC

TI

VA

TE

S

BU

IL

DI

NG

S

IN

TE

RI

OR

N

OT

IF

IC

AT

IO

N

DE

VI

CE

S

REQUIRED FIRE SAFETY CONTROLFACP FUNCTION

AC

TU

AT

ES

T

RO

UB

LE

C

ON

DI

TI

ON

A

T

CO

NT

RO

L P

AN

EL

PU

LS

IN

G

SO

UN

DE

R

W

IL

L T

UR

N

ON

, U

NT

IL

A

CK

NO

W

LE

DG

ED

AC

TU

AT

ES

S

UP

ER

VI

SO

RY

C

ON

DI

TI

ON

A

T

CO

NT

RO

L P

AN

EL

GR

EE

N

AC

P

OW

ER

IN

DI

CA

TO

R

IS

LI

T

ST

EA

DI

LY

ON

C

ON

TR

OL

P

AN

EL

CH

AR

AC

TE

R

LC

D

DI

SA

PL

Y

DI

SP

LA

Y

TH

E

CU

ST

OM

M

ES

SA

GE

"A

LL

S

YS

TE

MS

N

OR

MA

L"

AC

TU

AT

ES

A

LA

RM

C

ON

DI

TI

ON

A T

CO

NT

RO

L P

AN

EL

RE

CO

RD

IN

G

OF

T

HE

E

VE

NT

IN

S

YS

TE

MS

M

EM

OR

Y

PU

LS

IN

G

SO

UN

DE

R

W

IL

L T

UR

N

ON

, U

NT

IL

A

CK

NO

W

LE

DG

ED

FI

RE

A

LA

RM

C

ON

TR

OL

P

AN

EL

R

ET

UR

NS

T O

NO

RM

AL

NOTIFICATION/ANN

MANUAL PULL STATION

SH

UT

D

OW

N

OF

R

ES

PE

CT

IV

E

HV

AC

U

NI

T

AC

TI

VA

TE

E

LE

VA

TO

R

FI

RE

D

EP

AR

TM

EN

T (F

LA

SH

IN

G)

L

IG

HT

- ELEVATOR LOBBY - (Second Floor)

HEAT DETECTORS

- BOTTOM OF ELEVATOR SHAFT

AC

TI

VA

TE

E

LE

VA

TO

R

FI

RE

D

EP

AR

TM

EN

T (S

TE

AD

Y) L

IG

HT

A B C D E F G H I J K L M N O P Q R S T

U

- ELEVATOR MACHINE ROOM (First Floor)

PR

IO

R

TO

S

PR

IN

KL

ER

H

EA

D

AC

TI

VA

TI

ON

SH

UT

DO

W

N

PO

W

ER

T O

AF

FE

CT

ED

E

LE

VA

TO

R

MONITOR OF ELEVATOR SHUNT TRIP

DUCT (SMOKE) DETECTOR (Associated with RTU Units)

MONITORING OF REMOTE POWER SUPPLY

* FIRE SPRINKLER SYSTEM - ZONED WATERFLOW SWITCH (LATCHING)

FIRE SPRINKLER SYSTEM - MAIN WATERFLOW SWITCH (LATCHING)

TWO-WAY COMMUNICATION FUNCTIONS

POWER SUPPLY TROUBLE

Fire Alarm System Matrix

FIRE SPRINKLER SYSTEM - VALVE TAMPER SWITCH

MICROPHONE ACTIVATION WITH CIRCUIT SELECTION SWITCH

(V

OI

CE

E

VA

CU

AT

IO

N

SP

EA

KE

RS

AC

TI

VA

TE

S

BU

IL

DI

NG

S

IN

TE

RI

OR

N

OT

IF

IC

AT

IO

N

DE

VI

CE

S

- ELEVATOR MACHINE ROOM (First Floor)

- ASSOCIATED WITH SMOKE DAMPERS

V

RE

LE

AS

E

SM

OK

E

DA

MP

ER

S

RE

LE

AS

E

MA

GN

ET

IC

AL

LY

H

EL

D

OP

EN

D

OO

RS

- BOTTOM OF ELEVATOR SHAFT

(C

ON

TA

CT

ID

) T

O U.

L.

CL

AS

S

CE

NT

RA

L S

TA

TI

ON

(C

ON

TA

CT

ID

) T

O U.

L.

CL

AS

S

CE

NT

RA

L S

TA

TI

ON

(C

ON

TA

CT

ID

) T

O U.

L.

CL

AS

S

CE

NT

RA

L S

TA

TI

ON

(C

ON

TA

CT

ID

) T

O U.

L.

CL

AS

S

CE

NT

RA

L S

TA

TI

ON

TR

AN

SM

IT

S W

AT

ER

FL

OW

C

ON

DI

TI

ON

V

IA

C

EL

LU

LA

R

CO

MM

UN

IC

AT

OR

TR

AN

SM

IT

S

TR

OU

BL

E

CO

ND

IT

IO

N

VI

A

CE

LL

UL

AR

C

OM

MU

NI

CA

TO

R

TR

AN

SM

IT

S

SU

PE

RV

IS

OR

Y

CO

ND

IT

IO

N

VI

A

CE

LL

UL

AR

C

OM

MU

NI

CA

TO

R

TR

AN

SM

IT

S

AL

AR

M

CO

ND

IT

IO

N

VI

A

CE

LL

UL

AR

C

OM

MU

NI

CA

TO

R

- ASSOCIATED WITH MAGNETIC DOOR HOLD OPENS

W

SE

CU

RE

D

DO

OR

S

SE

ND

S

IG

NA

L T

O

SE

CU

RI

TY

S

YS

TE

M

- U

NL

OC

K

AL

L

DI

SP

LA

Y

AC

TI

VI

TY

O N

RE

MO

TE

LC

D

AN

NU

NC

IA

TO

R

X

AN

NU

NC

IA

TO

RS

(B

OT

H

SP

EA

KE

RS

A

ND

S

TR

OB

ES

W

IL

L S

TO

P)

NO

TI

FI

CA

TI

ON

A

PP

LI

AN

CE

S

SH

AL

L B E

SI

LE

NC

EA

BL

E

AT

T

HE

FA

CP

O

R

Number of Sheets:

By

Installing Fire Alarm System Contractor:

Date

Drawn By:

Drawn Date:

Scale:

Drawing No.

Revisions Description

Authority Having Jurisdiction:

Project Contacts

DHL

06/28/2024

VA

W al la

W al la

B ui ld in g

W ai nw rig ht

D riv e W al la

W al la , W

A

Li fe

S af et y

(F ire

A la rm S ys te m ) D ra w in gs

COPYRIGHT NOTICE

ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN

CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF

VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED

OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF

VULCAN FIRE

Reviewed by:

ENGINEERED SYSTEM DISTRIBUTION

by Honeywell

TM

Vulcan Project #: FI23-013

U .S

.D ep ar tm en t o f V et er an s A ffa irs

Fi re

A la rm S ys te m R ep la ce m en t -

P ha se B

Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362

(509) 524-4603

Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814

(208) 277-0171

GC

L ice ns e:

V

UL

CA

F*

0M

El ec

L ice ns e:

V

UL

CA

F*

W

EB

SI

TE

: w w w

.v ul ca nf ire us

.c om

PH

ON

E

(2

) 2

-0

Ea st H az el

A ve nu e, S ui te

1, C oe ur d 'A le ne

, I da ho

Record Drawings (5/9/2025)

N/A

FA-2.2

VOLTAGE DROPS ARE CALCULATED AT 16VDC.

L= ONE WAY LENGTH OF CIRCUIT(FEET)

WHERE VD= VOLTAGE DROP

R= 3.19 OHMS PER THOUSAND

I= LOAD CURRENT(AMPERES)

AFTER DETERMINING THE LENGTH OF THE HORN/STROBE CIRCUIT, USE

THE FOLLOWING FORMULA TO CALCULATE THE VOLTAGE DROP.

2xLxRxIVD=

LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD

ALLOWS FOR A SMALL MARGIN OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL

CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN ON THE SHOP SUBMITTAL

DRAWINGS. IF ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE

CIRCUIT LENGTH, CONTACT VULCAN FIRE.

VOLTAGE-DROP CALCULATION NOTE:

** STARTING VOLTAGE-DROP CALCULATIONS IS 20.4 PER UL 864, 9TH EDITION STANDARDS FOR FIRE ALARM

CONTROL PANELS.

Sheets and Views
FI23-013 VA Walla Walla Bldg-143 FA_Record-FA-0.0 (1)
FI23-013 VA Walla Walla Bldg-143 FA_Record-FA-1.1 (2)
FI23-013 VA Walla Walla Bldg-143 FA_Record-FA-1.2 (3)
FI23-013 VA Walla Walla Bldg-143 FA_Record-FA-2.1 (4)
FI23-013 VA Walla Walla Bldg-143 FA_Record-FA-2.2 (5)

File details come from the government source that posted it. Updated .