FI23-013-VA-Walla-Walla-Bldg-68-_Record.pdf

PDF 5 MB Posted

Attached to
H212 Fire Alarm Inspections, Testing, Maintenance & Repairs - Walla Walla VA - Dept of Veterans Affairs
Solicitation number
36C26025Q0599
Issued by

About this file

These documents are record drawings for a fire alarm system replacement project at Building 68 of the VA Walla Walla Medical Center. The project involves a comprehensive fire alarm system upgrade across multiple building levels, including the basement, first floor, second floor, and attic. The new Notifier fire alarm system will replace the existing system and includes voice evacuation notification appliances, elevator recall functions, fire sprinkler system monitoring, smoke and heat detectors, manual pull stations, and central monitoring capabilities.

The drawings detail specific technical specifications, including device placements, wiring configurations, and system interconnections. Key components include addressable devices, signaling line circuits, notification appliance circuits, and integration with elevator controls and magnetic door hold-open mechanisms. The project follows 2018 IBC, IFC, NFPA 72, and VA Fire Protection Manual standards. The system will be fully sprinklered and designed for a business occupancy (clinic, exam, offices) with synchronized voice evacuation and public mode visual notifications. The project is being implemented by Vulcan Fire, with record drawings dated 1/14/2025 and indicating a project number of FI23-013.

View the file

Other files

File Type Posted
S06 Amendment 36C26025Q0599 0002.pdf PDF
S02 RFQ 36C26025Q0599_1 Rev 7-31-2025.pdf PDF
S06 Amendment 36C26025Q0599 0001.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-135-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-65-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-69-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-140-FA_RECORD.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-143-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-66-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-31-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-82-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-49-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-81-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-75-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-T1-and-T2-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-T-7-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-80-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-145-FA_Record.pdf PDF
S02 RFQ 36C26025Q0599_1.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-76-FA.pdf PDF
PP_Questionnaire.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-41-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-74-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-77-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-78-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-48-FA_Record.pdf PDF
FI23-013-VA-Walla-Walla-Bldg-63-FA_Record.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SYSTEM INPUTS

PANEL FUNCTIONS

ALARM DEVICES

SYSTEM RESET

SYSTEM SILENCE

"ALL SYSTEMS NORMAL"

SMOKE DETECTORS

SUPERVISORY DEVICES

TROUBLE FUNCTIONS

ABNORMAL CIRCUIT OR DEVICE

FIRE ALARM SYSTEM AC POWER FAILURE

FIRE ALARM SYSTEM LOW BATTERY

SP

EA

KE

RS

A

ND

S

TR

OB

ES

S

TO

P

YE

LL

OW

LE

D W

IL

L F

LA

SH

A

ND

YE

LL

OW

LE

D W

IL

L F

LA

SH

A

ND

W

IL

L T

UR

N

ON

, U

NT

IL

S

IL

EN

CE

D.

RE

D

LE

D

AN

D

AU

IB

LE

S

OU

ND

ER

HI

ST

OR

Y

LO

G:

SYSTEM OUTPUTS

(S

YN

CH

RO

NI

ZE

D

AN

D

VO

IC

E

EV

AC

TE

MP

OR

AL

P

AT

TE

RN

AC

TI

VA

TE

S

BU

IL

DI

NG

S

IN

TE

RI

OR

N

OT

IF

IC

AT

IO

N

DE

VI

CE

S

REQUIRED FA CONTROLFACP FUNCTION

AC

TU

AT

ES

T

RO

UB

LE

C

ON

DI

TI

ON

A

T

CO

NT

RO

L P

AN

EL

PU

LS

IN

G

SO

UN

DE

R

W

IL

L T

UR

N

ON

, U

NT

IL

A

CK

NO

W

LE

DG

ED

AC

TU

AT

ES

S

UP

ER

VI

SO

RY

C

ON

DI

TI

ON

A

T

CO

NT

RO

L P

AN

EL

GR

EE

N

AC

P

OW

ER

IN

DI

CA

TO

R

IS

LI

T

ST

EA

DI

LY

ON

C

ON

TR

OL

P

AN

EL

CH

AR

AC

TE

R

LC

D

DI

SA

PL

Y

DI

SP

LA

Y

TH

E

CU

ST

OM

M

ES

SA

GE

"A

LL

S

YS

TE

MS

N

OR

MA

L"

AC

TU

AT

ES

A

LA

RM

C

ON

DI

TI

ON

A T

CO

NT

RO

L P

AN

EL

RE

CO

RD

IN

G

OF

T

HE

E

VE

NT

IN

S

YS

TE

MS

M

EM

OR

Y

PU

LS

IN

G

SO

UN

DE

R

W

IL

L T

UR

N

ON

, U

NT

IL

A

CK

NO

W

LE

DG

ED

FI

RE

A

LA

RM

C

ON

TR

OL

P

AN

EL

R

ET

UR

NS

T O

NO

RM

AL

NOTIFICATION

MANUAL PULL STATION

A B C D E F G H I J K L M N O P Q R

* FIRE SPRINKLER SYSTEM - ZONED WATERFLOW SWITCH (LATCHING)

FIRE SPRINKLER SYSTEM - MAIN WATERFLOW SWITCH (LATCHING)

Fire Alarm System Matrix

FIRE SPRINKLER SYSTEM - VALVE TAMPER SWITCH

MICROPHONE ACTIVATION WITH CIRCUIT SELECTION SWITCH

(C

ON

TA

CT

ID

) T

O U.

L.

CL

AS

S

CE

NT

RA

L S

TA

TI

ON

(C

ON

TA

CT

ID

) T

O U.

L.

CL

AS

S

CE

NT

RA

L S

TA

TI

ON

(C

ON

TA

CT

ID

) T

O U.

L.

CL

AS

S

CE

NT

RA

L S

TA

TI

ON

(C

ON

TA

CT

ID

) T

O U.

L.

CL

AS

S

CE

NT

RA

L S

TA

TI

ON

TR

AN

SM

IT

S W

AT

ER

FL

OW

C

ON

DI

TI

ON

V

IA

C

EL

LU

LA

R

CO

MM

UN

IC

AT

OR

TR

AN

SM

IT

S

TR

OU

BL

E

CO

ND

IT

IO

N

VI

A

CE

LL

UL

AR

C

OM

MU

NI

CA

TO

R

TR

AN

SM

IT

S

SU

PE

RV

IS

OR

Y

CO

ND

IT

IO

N

VI

A

CE

LL

UL

AR

C

OM

MU

NI

CA

TO

R

TR

AN

SM

IT

S

AL

AR

M

CO

ND

IT

IO

N

VI

A

CE

LL

UL

AR

C

OM

MU

NI

CA

TO

R

AN

NU

NC

IA

TO

RS

(B

OT

H

SP

EA

KE

RS

A

ND

S

TR

OB

ES

W

IL

L S

TO

P)

NO

TI

FI

CA

TI

ON

A

PP

LI

AN

CE

S

SH

AL

L B E

SI

LE

NC

EA

BL

E

AT

T

HE

FA

CP

O

R

- ELEVATOR LOBBY - (First Floor)

- SPOT TYPE DETECTORS, (All, except as specifically noted below)

- ELEVATOR LOBBY - (Second Floor)

- ELEVATOR MACHINE ROOM (Basement)

- TOP OF ELEVATOR SHAFT

EL

EV

AT

OR

R

EC

AL

L (

PR

IM

AR

Y)

EL

EV

AT

OR

R

EC

AL

L T

O

SE

CO

ND

FL

OO

R

EL

EV

AT

OR

R

EC

AL

L (

AL

TE

RN

AT

E)

EL

EV

AT

OR

R

EC

AL

L T

O

FI

RS

T

FL

OO

R

AC

TI

VA

TE

E

LE

VA

TO

R

FI

RE

D

EP

AR

TM

EN

T

(F

LA

SH

IN

G) L

IG

HT

AC

TI

VA

TE

E

LE

VA

TO

R

FI

RE

D

EP

AR

TM

EN

T (S

TE

AD

Y) L

IG

HT

PR

IO

R

TO

S

PR

IN

KL

ER

H

EA

D

AC

TI

VA

TI

ON

SH

UT

DO

W

N

PO

W

ER

T O

AF

FE

CT

ED

E

LE

VA

TO

R

S

HEAT DETECTORS

- ELEVATOR MACHINE ROOM (Basement)

- TOP OF ELEVATOR SHAFT

- BOTTOM OF ELEVATOR SHAFT

- ELEVATOR MACHINE ROOM (Attic)

- ELEVATOR MACHINE ROOM (Attic)

FIRE SPRINKLER SYSTEM - DRY SYSTEM - LOW AIR

- ASSOCIATED WITH MAGNETIC DOOR HOLD OPENS

RE

LE

AS

E

MA

GN

ET

IC

AL

LY

H

EL

D

OP

EN

D

OO

RS

ON

YX

W

OR

KS

S

TA

TI

ON

IN

B

UI

LD

IN

G

SE

CU

RI

TY

O

FF

IC

E

TR

AN

SM

IT

S

SY

ST

EM

C

ON

DI

TI

ON

V

IA

FI

BE

R

NE

TW

OR

K

NE

TW

OR

K

AN

NU

NC

IA

TO

R

IN

B

UI

LD

IN

G

P

OL

IC

E

ST

AT

IO

N

TR

AN

SM

IT

S

SY

ST

EM

C

ON

DI

TI

ON

V

IA

FI

BE

R

NE

TW

OR

K

T U

Number of Sheets:

By

Installing Fire Alarm System Contractor:

Date

Drawn By:

Drawn Date:

Scale:

Drawing No.

Revisions Description

Authority Having Jurisdiction:

Project Contacts

DHL

04/22/2024

VA

W al la

W al la

B ui ld in g

W ai nw rig ht

D riv e W al la

W al la , W

A

Li fe

S af et y

(F ire

A la rm S ys te m ) D ra w in gs

COPYRIGHT NOTICE

ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN

CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF

VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED

OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF

VULCAN FIRE

Reviewed by:

ENGINEERED SYSTEM DISTRIBUTION

by Honeywell

TM

Vulcan Project #: FI23-013

Signature:____________________________

U .S

.D ep ar tm en t o f V et er an s A ffa irs

Fi re

A la rm S ys te m R ep la ce m en t -

P ha se B

Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362

(509) 524-4603

Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814

(208) 277-0171

GC

L ice ns e:

V

UL

CA

F*

0M

El ec

L ice ns e:

V

UL

CA

F*

W

EB

SI

TE

: w w w

.v ul ca nf ire us

.c om

PH

ON

E

(2

) 2

-0

Ea st H az el

A ve nu e, S ui te

1, C oe ur d 'A le ne

, I da ho

Record Drawings (1/14/2025)

N/A

FA-0.0

Site Plan

General Notes:

Drawing Notes:

Fire Alarm Control Panel Terminations:

Scope of Work:

All wiring runs shown on the fire alarm shop drawings are conceptual only. They do not and are not intended to be actual wire runs or conduit runs. Device interconnect is intended to show only sequence of device connections and type of wire.

Please review both the floor plans and the riser diagram drawings to resolve any conflicts or questions that may come up. If the drawings do not answer your questions, please call Vulcan Fire for help to answer your questions.

Electrical Contractor is advised not to complete terminations at the Fire Alarm Control Panel. Terminations will be completed by a qualified Vulcan Fire Technician.

Code Analysis:

Edition of Codes:

Number of Stories:

Edition of Standards:

Occupancy Type: B, Business (Clinic, Exam, Offices) S-1 Storage (Storage Closets)

2018 IBC, IFC, IMC

2018 NFPA 101

City of Walla Walla Amendments 2009 ANSI 117.1 Guidelines for Accessible & Useable

Yes, Fully Fire Sprinklered

3 Stories & Attic

2016 NFPA 72, 2020 NFPA 70 (NEC), VA Fire Protection Manual

Visual Notification: Public Mode

Wire runs are indicated by AlphaNumeric designations.

power run of "2#__ " cable. A designation of "P3" would indicate another individual run of "2#__ " cable.

"2#__Twisted AND a run of 2#__ " cable.

A designation of "A,P2", would refer to a run of

The wire Gauge of any wire run is determined by the

A designation of "P2", would refer to a individual pair, 2#__ Twisted" cable.

A designation of "2A", would refer to a run of "2 length of the wire run and the power load on that run.

A typical wire run designated as "A", would refer to a single run of "2 #__ Twisted" cable.

For example:

A,P2

P2,P3

A

2A

Wire Chart:

Audible Notification: Voice Evac - Temporal 3 Pattern / Synchronized

Type of FA System: New Fire Alarm Addressable System

Index of Drawings Drawing Name

Drawing Number

Cover SheetCover Sheet / Fire Alarm MatrixFA-0.0

FA-1.2

Basement - Fire Alarm Plan

Temporal Pattern Notification Device Numbering:

(IE: HORN/STROBE)

AUDIBLE/VISUAL DEVICE

(IE: STROBE ONLY)

AUDIBLE DEVICE

(IE: HORN ONLY)

WITH THE REQUIREMENTS FOR VISUAL DEVICES.

1. ADA ACCESSIBILITY GUIDELINES HAVE ACCEPTED NFPA 72 GUIDELINES AS "EQUIVALENT FACILITATION".

3. MEASUREMENT IS TO THE BOTTOM OF THE DEVICE.

2. NFPA 72 STATES THAT COMBINATION AUDIBLE/VISUAL DEVICES SHALL BE MOUNTED IN ACCORDANCE

NOTES:

AFF = ABOVE FINISHED FLOOR0" (FLOOR)

NFPA 72

A

90" A.F.F.

A/V

96" A.F.F.

80" A.F.F.

NFPA 72

MAX.

MIN.

V

VISUAL DEVICE

CEILING

6" BELOW

CEILING

Example of Proper Mounting for Audible/Visual Devices:

Example of Junction Box Detail (FA):

If Applicable (Use for eample only)

Sheet Number

Walla Walla, WA 99362

U.S. Department Of Veterans Affairs VA Medical Center

77 Wainwright Drive

Owner

Fire Protection System:

Square Footage:

FA System Required: Code-Required (Designed as a Core & Shell per VA)

Project Manager: Dave Clem

GDM of Oregon 1584 McNeil Street, Suite 200

DuPont, WA 98327

Architect / Engineer

31,573 GSF

Protected Premises Fire Alarm Systems (Wiring):

Mounted Candela Rating:

S150 = 150 Candela S177 = 177 Candela S185 = 185 Candela

S135 = 135 Candela

S115 = 115 Candela S110 = 110 Candela S95 = 95 Candela S75 = 75 Candela S30 = 30 Candela S15 = 15 Candela

Ceiling S15C S15

Wattage Speaker 1W Tap

Guard WireWG WeatherproofWP

VOICE CIRCUIT

V 2

2S

POWER SUPPLY NUMBER

STROBE CIRCUIT

CIRCUIT NUMBER

AMPLIFIER NUMBER

CIRCUIT NUMBER

1 Class B

Class B

F P

VS VSAIM

Class B

IDC - Initiating Device Circuit Manual Pull Stations, Fire Sprinkler System, Etc.

NAC - Notification Appliance Circuit Speakers, Strobes, Etc.

SLC - Signaling Line Circuit Intelligent (Addressable) Devices FS

Where used, End-Of-Line Resistors shall be labeled "EOL" on the Device (per Owner)-

Building 68 77 Wainwright Drive, Walla Walla, WA 99362

Fire Alarm System Replacement

The scope of work for this project is to replace the existing campus fire alarm system with a new fire alarm system throughout. The existing copper cabling backbone infrastructure will be replaced with new fiber optic cabling. Each building will be provided with new fire alarm control panels connected to the campus network. A new campus wide computer monitoring and control system will be provided in Building 78.

Existing fire alarm devices such as pull stations, detectors, relay modules, monitor modules, flow and tamper switch interfaces, and associated conduit, boxes and cabling shall be demolished and replaced with new devices.

Building 68 Fire Alarm System:

The new Notifier fire alarm system in Building 68 will be replacing the existing fire alarm system. Voice evacuation notification appliances will be installed throughout the entire building, which will alert the occupants in the event of a fire. The FACP will provide control over elevator recall functions. The FACP will provide monitoring of the fire sprinkler system.

Smoke and Heat Detectors will be installed where required per codes, in electrical and mechanical spaces and as required to release magnetically held open doors. New manual pull station will be installed at building exits.

Fire sprinkler tamper switches will cause a supervisory signal when activated.

The fire alarm system shall be monitored through a central monitoring company of the owners choosing prior to the final inspection.

Riser Diagram / Details / Load Calculations / Speaker Calculations

N

All intelligent and or addressable Fire Alarm Devices must be placed in protected areas with ambient temperature ranging from 32° to 120°. Weatherproof Fire Alarm Devices have temperature rating from -40° to 151° in wet or dry applications.

Do not place smoke detectors within 3 feet of air supply registers and diffusers.

All intelligent devices shall be interconnected as shown on the riser on-line diagram. Each intelligent device is designed with an address. T-Tapping is permitted on SLC Loop (Class "B") only.

Wire runs show interconnected of fire alarm devices only. Wiring does not represent conduit runs.

Electrical Contractor is responsible for proper connection of equipment provided by others.

(RL) Indicates Existing Device to be relocated to new location.

(R) Indicates Device to be removed and returned to Owner.

(E) Indicates Device existing to remain (shown in gray scale).

(N) Indicates New Device.

(RR) Indicates Remove Existing Device and replace with new Device. Return any removed equipment to Owner.

Setting Initiating Device Addresses:

D:L1: 501

ONESTENS

7 8 9

00 15

D = Detector M = Monitor

Device AddressData Loop Number

DIALS ARE

LOCATED ON THE

BACK OF EACH

DEVICE

Typical Device Mounting Height:

NFPA 2016

Wall Mounted AUDIBLE device.

Top of Individual Device

MAX

4'-0"

"ADA"

(48")

Top of Device of the Same Lens

Top of Unit

Top of Cabinet

To Handle of Device Per NFPA 72 from (AFF) Above All heights measured

NOT TO SCALE

Finished Floor

BOTTOM

OF

6'-0"

80" TO

MIN* (72")

LENS

See Note #5

7'-0"

TO TOP

OF

Approx.96"

MAX*

(84")LENS

(6")

THAN

BELOW

CEILING

(90")

AND

LESS

THAN

NOT

LESS

NOT

(64") 5'-4" or 80" MIN. to Bottom A/V or Visual Only Devices

MAX 96" to Top of Lens for all

#1) HEIGHTS SHOWN ARE LISTED IN NFPA STANDARDS 2016.

#2) MOUNTING HEIGHTS LISTED IN SPECIFICATIONS OR SHOWN ON THE

ARCHITECTURAL ELEVATIONS SHALL GOVERN. ANY DISCREPANCY SHALL BE

BROUGHT TO THE ATTENTION OF THE AHJ AND THE ENGINEER OF RECORD.

#3) WALL MOUNTED ADA STROBES & HORN/STROBES ARE TO BE PLACED

A MINIMUM OF 80" ABOVE FINISHED FLOOR MEASURED AT THE BOTTOM OF

THE LENS OR 6" BELOW THE CEILING TO THE TOP OF THE LENS,

WHICHEVER IS LOWEST. THE MAXIMUM HEIGHT MEASURED AT THE TOP OF

THE LENS SHALL NOT EXCEED 96".

#4) IN SLEEPING ROOMS A STROBE MOUNTED LESS THAN 24" FROM THE

CEILING SHALL BE AT LEAST 177CD. STROBES MOUNTED 24" OR BELOW

SHALL BE AT LEAST 110 CD. A STROBE SHALL BE MOUNTED WITHIN 16FT

OF THE PILLOW.

#5) REMOTE LIGHTS, TEST STATIONS AND MODULES SHOULD BE MOUNTED

SO AS TO BE ACCESSIBLE, YET ABOVE EASY REACH TO PREVENT

VANDALISM.

#6) CEILING MOUNT VISIBLE DEVICES SHALL BE SPACED ACCORDING TO

2016 NFPA 72.

FSA

FACFACP RPS

AIM AOM

F

RL

S15H15 15MC15

RT

J DM

MAP FTR

C

AOM

R

S

(48") 4'-0"

*MAX

(42") 3'-6"

*MIN

U.S. Department of Veterans Affairs

VA WALLA WALLA - FIRE LIFE SAFETY - PHASE B Fire Alarm Systems Interconnect Drawings

X

X X

X X

X

X

X

X

XX X

X

X

X

X

X

X

STATE NURSING HOME

STATE NURSING HOME

STATE NURSING HOME

STATE NURSING HOME

N U

R

SIN

G H

O M

E

FU

TU

R E

BL

D

G

7 49 48

66T-7

77T-1

T-2

756968

116119

121126125124

109CM

147 146

W

SITEN1:

Node Number

FA-2.1

First Floor - Fire Alarm Plan3

FA-1.1

MAP

RPS

BATT

S P

VS

WF

AOM

R

R

F

S15C

S30C

S75C

SS

FARC

Indicates Circuit Continuation Indicates Home Run to FACP

DH

AIM

FACP

S135

PS

PS LA

WF

FATC

F135°

(E)

WP

15C

FA-1.4

Second Floor - Fire Alarm Plan4 Attic - Fire Alarm Plan5

FA-1.3

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text PRV Vault

AutoCAD SHX Text F/A

AutoCAD SHX Text 8"

AutoCAD SHX Text Caps

AutoCAD SHX Text Tank

AutoCAD SHX Text Fuel

AutoCAD SHX Text F/A

AutoCAD SHX Text Valves

AutoCAD SHX Text

PRV

AutoCAD SHX Text F/A

B102E

STORAGE

B102C

B102F

MEN'S LOCKER

ROOM

B102

WOMEN'S

LOCKER

B117

CB-1

STORAGE

B104

STORAGE

B103

WATER HEATERS/

STEAM SHUT-OFF

B105

RESTROOM/

SHOWER

B102B

STORAGE

B102D

STORAGE

B102A

ELEVATOR

CONTROL

B101

FIRE

SPRINKLER

SYSTEM VALVE

B104

CB-2

CB-3

STORAGE

B115

STORAGE

B113

STORAGE

B114

CB-3

B116

CB-5

CB-4

ELEC.

SWITCHGEAR

B107STORAGE

B108B109

B110

STORAGE

B111

VACANT/

STORAGE

B111A

STEAM

ROOM

B112

B110F

B110A

B110B MECH

B110C B110D

STORAGE

B110E

VACANT/

WORK ROOM

VACANT/

STORAGE

STORAGE

VACANT/

WORK ROOM

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

CORR.

CORR.

CORR.CORR.

CORR.

CORR.

VACANT/

STORAGE

STORAGE

Elevator #1 Control

120VAC Shunt Trip Power Source

Primary Recall (Steady) Alternate Recall (Steady)

Shunt Trip Breaker

Fire Light Indicator (Flashing)

R

FATCXP6-R

Sp ar e Sp ar e

47k

R

N2 2:

L1 :M

N2 2:

L1 :M

N2 2:

L1 :M

N2 2:

L1 :M

N2 2:

L1 :M

N22:L1:M031

N2 2:

L1 :M

AIM

Elevator Controls (Field Verify Location) F

F

F F

S75C 1W

S75C 1W

S75C 1W

S15C 1W

S15C

S75C 1W

DH(E)

DH

(E)

P P

P S P

S P

S30C 1W

S75C

S15C

S15C 1W

S75C 1W

S75C 1W

15C

WP

S30C 1W

S30C

TLT

B102D

PF135°

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M035

F135°

5 H

VS

Main - Fire Sprinkler System

WF

N16:L1:M015

N16:L1:M016

VS

N16:L1:M019

N16:L1:M020

Field verify Fire Sprinkler connections.

WF

N16:L1:M017

N16:L1:M018

VS

AIM

AIM

AIM

AIM

PS

PS

LA

WF

AIM

AIM

To

FACP

To

RPS#1

To

RPS#1

S75C 1W

S1-1 V0-1

S1-1 V0-1

S1-1 V0-1

S1-1 V0-1

S1-1 V0-1

S1-1

S1-1

S1-2 V0-1

S1-2 V0-1

S1-2 V0-1

S1-2 V0-1

S1-2 V0-1

S1-2 V0-1

S1-2 V0-1

S1-2 V0-1

S1-2 V0-1

S1-1 V0-1

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M036

N22:L1:M005

N22:L1:M006

N22:L1:M007

N22:L1:M008

N22:L1:D021

N22:L1:D022 N22:L1:D023

N22:L1:D024

P N22:L1:D025

P

N22:L1:D028 N22:L1:D029

N22:L1:D026

N22:L1:D027

N22:L1:D030

15S1-1

S

S

S

H SS

S

Main Trunk Line to J-Box

Panel

J

J

JJ

J

J J

J

J

J

JJ

J

J

J

J

J

Fiber up to 1st Floor

D

Backflow Preventer

D

DD

D

D

D

D

S V

S,V

S,2V

S,2V

S,2V

S,2V

S,2V

S,2V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,2VS

F

S,V

A

A

A

A

A

A

A

A

A

A

P

P

P

P

F

F

F

A

A

A

A A

A

A

A

A

General Note:

* All addressable devices require SLC Loop (A-wire) from the FACP to operate. For help, please refer to riser diagram for reference.

* Do not route conduit into the bottom of any fire alarm system component cabinets.

* After each duct smoke detector has been installed use a Megnehelic

Test Instrument to verify adequate air flow, show the results on the Shop Drawings for the AHJ's review.

* Tap all speakers at 1/2 watt - 25 volts unless otherwise indicated at individual device.

* Contractor may reuse existing pathways where available. Verify with system designer prior to adding additional devices or extending circuits to ensure voltage drop calculations are within acceptable limits.

* Building is known to contain asbestos. Contractor shall comply with asbestos abatement procedures identified in Project Specification section 028211 "Traditional Asbestos Abatement".

1) Section of NFPA 72, National Fire Alarm Code requires units to be provided with smoke detection in areas that are not continuously occupied.

2) Provide Dedicated 120VAC circuit to the FACP label the Dedicated circuit breaker "Fire Alarm." In red with lockout. Location of breaker shall be noted at FACP.

3) Fiber Network routing to be field coordinated.

4) Detector is to activate Elevator Recall Functions.

5) Detector is to activate Elevator Shunt Trip. Mount within 24" of Sprinkler

Head.

6) Not Used.

7) Detector is to activate Door Release Service (Magnetic Door Hold Opens).

8) Smoke detection omitted in areas where not required by Code or VA Fire

Protection Manual.

9) Attic Level notification devices to be mounted on horizontal beams.

Reuse existing pathways and mounting fixtures where possible.

Flag Notes: (Some flag notes may not appear on every sheet)

Addressing Legend:

D = Detector M = Module

Module/Device Number M01L01

Loop Number N01Node Number

Number of Sheets:

By

Installing Fire Alarm System Contractor:

Date

Drawn By:

Drawn Date:

Scale:

Drawing No.

Revisions Description

Authority Having Jurisdiction:

Project Contacts

DHL

04/22/2024

VA

W al la

W al la

B ui ld in g

W ai nw rig ht

D riv e W al la

W al la , W

A

Li fe

S af et y

(F ire

A la rm S ys te m ) D ra w in gs

COPYRIGHT NOTICE

ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN

CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF

VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED

OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF

VULCAN FIRE

Reviewed by:

ENGINEERED SYSTEM DISTRIBUTION

by Honeywell

TM

Vulcan Project #: FI23-013

Signature:____________________________

U .S

.D ep ar tm en t o f V et er an s A ffa irs

Fi re

A la rm S ys te m R ep la ce m en t -

P ha se B

Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362

(509) 524-4603

Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814

(208) 277-0171

GC

L ice ns e:

V

UL

CA

F*

0M

El ec

L ice ns e:

V

UL

CA

F*

W

EB

SI

TE

: w w w

.v ul ca nf ire us

.c om

PH

ON

E

(2

) 2

-0

Ea st H az el

A ve nu e, S ui te

1, C oe ur d 'A le ne

, I da ho

Record Drawings (1/14/2025)

1/8" = 1'-0"

FA-1.1

Scale: 1/8'' = 1'-0''

20 4 8 16 32

Basement - Fire Alarm System Plan

General Note:

* All addressable devices require SLC Loop (A-wire) from the FACP to operate. For help, please refer to riser diagram for reference.

* Do not route conduit into the bottom of any fire alarm system component cabinets.

* After each duct smoke detector has been installed use a Megnehelic

Test Instrument to verify adequate air flow, show the results on the Shop Drawings for the AHJ's review.

* Tap all speakers at 1/2 watt - 25 volts unless otherwise indicated at individual device.

* Contractor may reuse existing pathways where available. Verify with system designer prior to adding additional devices or extending circuits to ensure voltage drop calculations are within acceptable limits.

* Building is known to contain asbestos. Contractor shall comply with asbestos abatement procedures identified in Project Specification section 028211 "Traditional Asbestos Abatement".

1) Section of NFPA 72, National Fire Alarm Code requires units to be provided with smoke detection in areas that are not continuously occupied.

2) Provide Dedicated 120VAC circuit to the FACP label the Dedicated circuit breaker "Fire Alarm." In red with lockout. Location of breaker shall be noted at FACP.

3) Fiber Network routing to be field coordinated.

4) Detector is to activate Elevator Recall Functions.

5) Detector is to activate Elevator Shunt Trip. Mount within 24" of Sprinkler

Head.

6) Not Used.

7) Detector is to activate Door Release Service (Magnetic Door Hold Opens).

8) Smoke detection omitted in areas where not required by Code or VA Fire

Protection Manual.

9) Attic Level notification devices to be mounted on horizontal beams.

Reuse existing pathways and mounting fixtures where possible.

Flag Notes: (Some flag notes may not appear on every sheet)

Addressing Legend:

D = Detector M = Module

Module/Device Number M01L01

Loop Number N01Node Number

F

S P1

DH

DH

DH

DH

DH

DH

DH

DH

DH

DHDH

DH

F

F F

S15C 1W

S15C 1W

127A

132C1-5

134 135

C1-4

C1-6

114B

114A

117A 116A

C1-1

112B 112A

C1-1

105A

C1-2

103A

C1-1

C1-3

C1-3

RESTROOM

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

SHOWER

VACANT/

STORAGE

VACANT/

STORAGE

STORAGE

STORAGE STORAGE

STORAGE

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

SHOWER

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

RECEPTION

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

TLT

VACANT/

STORAGE

BREAK

CORR.

CORR.

CORR.

CORR.

S15C 1W

S15C 1W

(E)

S P

S P

S P

S P

S P

S P

S P

S P

S P

S P

S P

S P

S P

S P

S15C 1W

S75C 1W

CORR.

S

P S

P

(E)

(E) (E)

S75C 1W

S75C 1W

S P

S15C 1W

S15C

TLT TLT

15 15

(E)

(E)

(E)

(E)

(E) (E)

(E)

(E)

S15C

CORR.

CC

15C

WP

15C

WP

STORAGE

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M038

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M037

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M039

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M042

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M043

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M044

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M040

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M041

N22:L1:M010

Security System Unlock Doors

AOM

RField

Verify

Dedicated

120VAC

SS

FARC

MAP

To Bldg. Devices (SLC Loop)

FACP

Spkr Crkts V0-1, V0-2, V0-3, V0-4,BATT

NAC Crkts X0-1, S0-2, S0-3, S0-4, RPS

NAC Crkts S1-1, S1-2, S1-3, S1-4, S1-5, S1-6

AIM

Components located inside of

FACP

#1

EVAC

N22:L1:M013

CPU2-640

HS-NCM-MF

NCA-2

DVC / CMIC-1

DAA2-5025

To Fiber Network Patch Panel5

X0-1

S75C 1W

S15C

To

FACP

To

RPS#1

To

RPS#1

S30C

SHOWER

15C

WP

SS

To

FACP

S0-2 V0-2

S0-2 V0-2

S0-2 V0-2

S0-2 V0-2

S0-2 V0-2

S0-2

V0-2

S0-2

S0-2

S0-3 V0-3

S0-3 V0-3

S0-3 V0-3

S0-3 V0-3

S0-3 V0-3

S0-3 V0-3

S0-3 V0-3

S0-3 V0-3

S0-3

V0-3

S0-3

S0-3

S0-3

N22:L1:M001

N22:L1:D001

N22:L1:M004

N22:L1:M002 N22:L1:M004

N22:L1:D002

N22:L1:D003N22:L1:D004

N22:L1:D005

N22:L1:D006N22:L1:D007 N22:L1:D008

N22:L1:D009

N22:L1:D010

N22:L1:D011

N22:L1:D012

N22:L1:D015 N22:L1:D016

N22:L1:D017

N22:L1:D018

N22:L1:D013

N22:L1:D014

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M042

DH

DH

S0-2 V0-2

J

J

J

J

J

J

J

J

J

J

J

J

J

J J J

J

J

J

J J

J

J

J

J

J

J

J

J

J

J

J

J

J

EP

A

2F

D

X

S

S V

S,V

S,V

S,V

S,V

S,V

S,V

P

S,V

S,V

S,V

S,V

S,V

S,VS,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

F

V

F

F

F

P

PPP

PP

P

P

P

P F

A

A

A

A A

S,V

A

A

A

A

A

A

A

S,V

S,V

S,V

S,V

S,VS,V

A

A

A

P

P

A

A

A

A

A

A A

A

P

P P

Number of Sheets:

By

Installing Fire Alarm System Contractor:

Date

Drawn By:

Drawn Date:

Scale:

Drawing No.

Revisions Description

Authority Having Jurisdiction:

Project Contacts

DHL

04/22/2024

VA

W al la

W al la

B ui ld in g

W ai nw rig ht

D riv e W al la

W al la , W

A

Li fe

S af et y

(F ire

A la rm S ys te m ) D ra w in gs

COPYRIGHT NOTICE

ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN

CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF

VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED

OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF

VULCAN FIRE

Reviewed by:

ENGINEERED SYSTEM DISTRIBUTION

by Honeywell

TM

Vulcan Project #: FI23-013

Signature:____________________________

U .S

.D ep ar tm en t o f V et er an s A ffa irs

Fi re

A la rm S ys te m R ep la ce m en t -

P ha se B

Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362

(509) 524-4603

Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814

(208) 277-0171

GC

L ice ns e:

V

UL

CA

F*

0M

El ec

L ice ns e:

V

UL

CA

F*

W

EB

SI

TE

: w w w

.v ul ca nf ire us

.c om

PH

ON

E

(2

) 2

-0

Ea st H az el

A ve nu e, S ui te

1, C oe ur d 'A le ne

, I da ho

Record Drawings (1/14/2025)

1/8" = 1'-0"

FA-1.1

Scale: 1/8'' = 1'-0''

20 4 8 16 32

First Floor - Fire Alarm System Plan

AutoCAD SHX Text

EXIT

AutoCAD SHX Text

EXIT

AutoCAD SHX Text

EXIT

EXIT

operate. For help, please refer to riser diagram for reference.

* Do not route conduit into the bottom of any fire alarm system component cabinets.

* After each duct smoke detector has been installed use a Megnehelic

Test Instrument to verify adequate air flow, show the results on the Shop Drawings for the AHJ's review.

* Tap all speakers at 1/2 watt - 25 volts unless otherwise indicated at individual device.

* Contractor may reuse existing pathways where available. Verify with system designer prior to adding additional devices or extending circuits to ensure voltage drop calculations are within acceptable limits.

* Building is known to contain asbestos. Contractor shall comply with asbestos abatement procedures identified in Project Specification section 028211 "Traditional Asbestos Abatement".

1) Section of NFPA 72, National Fire Alarm Code requires units to be provided with smoke detection in areas that are not continuously occupied.

2) Provide Dedicated 120VAC circuit to the FACP label the Dedicated circuit breaker "Fire Alarm." In red with lockout. Location of breaker shall be noted at FACP.

3) Fiber Network routing to be field coordinated.

4) Detector is to activate Elevator Recall Functions.

5) Detector is to activate Elevator Shunt Trip. Mount within 24" of Sprinkler

Head.

6) Not Used.

7) Detector is to activate Door Release Service (Magnetic Door Hold Opens).

8) Smoke detection omitted in areas where not required by Code or VA Fire

Protection Manual.

9) Attic Level notification devices to be mounted on horizontal beams.

Reuse existing pathways and mounting fixtures where possible.

Flag Notes: (Some flag notes may not appear on every sheet)

Addressing Legend:

D = Detector M = Module

Module/Device Number M01L01

Loop Number N01Node Number

RESTROOM

STORAGE

HOUSEKE.

CLOSET

202203

STORAGE

201A

STORAGE

205A

204205206

STORAGE

C2-3 C2-3

C2-2

222221220219

C2-5

RESTROOM

VACANT/

STORAGE

CONFERENCE/

CLASSROOM

C2-6

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

VACANT/

STORAGE

CORR.

CORR.

CORR. CORR.

CORR.

C2-7

CORR.

F F

S P

S P

S P

S P

S P

S P

S P

S P

S P

DHDH

(E) (E) DH

(E)

DHDH

(E) (E)

S15C 1W

S75C 1W

S75C 1W

S15C 1W

S15C 1W

S75C 1W

S75C 1W

S15C 1W

VACANT/

STORAGE

S75C 1W S75C

1W

VACANT/

STORAGE

S15C 1W

S15C 1W

S75C 1W

S75C 1W

S135 1W

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M048

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M047

DH (E)

DH (E)

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M046

To Magnetic Door Hold

Opens

120VAC AOM

R

R

N22:L1:M045

To

FACP

To

RPS#1

To

RPS#1

To

FACP

S1-3 V0-4

S1-3 V0-4

S1-3 V0-4

S1-3 V0-4

S1-3 V0-4

S1-3 V0-4

S1-3 V0-4

S1-3 V0-4

S1-3

S1-4 V0-5S1-4

V0-5

S1-4 V0-5

S1-4 V0-5

S1-4 V0-5

S1-4 V0-5

S1-4 V0-5

S1-4

7 7

F135°

5 H

N22:L1:M010

N22:L1:D035

N22:L1:D036 N22:L1:D037

N22:L1:D038

N22:L1:D039

N22:L1:D040

N22:L1:D042

N22:L1:D041

N22:L1:D043

N22:L1:D044

8 8

S1-4

S1-4

TLT

220A

TLT

221A

S135 1W

N22:L1:M009

J

J

J J

J

J

J J

J

J

DH

J J

J

SVS V

S,V

S,V

S,V

S,V

S,V

S,V

S,V S,V

S,V

S,V

S,V

S,V

S,V

S,V

S,V

PP

P

P

P

P

P P P

P P

A A

AA

AA

P

Number of Sheets:

By

Installing Fire Alarm System Contractor:

Date

Drawn By:

Drawn Date:

Scale:

Drawing No.

Revisions Description

Authority Having Jurisdiction:

Project Contacts

DHL

04/22/2024

VA

W al la

W al la

B ui ld in g

W ai nw rig ht

D riv e W al la

W al la , W

A

Li fe

S af et y

(F ire

A la rm S ys te m ) D ra w in gs

COPYRIGHT NOTICE

ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN

CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF

VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED

OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF

VULCAN FIRE

Reviewed by:

ENGINEERED SYSTEM DISTRIBUTION

by Honeywell

TM

Vulcan Project #: FI23-013

Signature:____________________________

U .S

.D ep ar tm en t o f V et er an s A ffa irs

Fi re

A la rm S ys te m R ep la ce m en t -

P ha se B

Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362

(509) 524-4603

Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814

(208) 277-0171

GC

L ice ns e:

V

UL

CA

F*

0M

El ec

L ice ns e:

V

UL

CA

F*

W

EB

SI

TE

: w w w

.v ul ca nf ire us

.c om

PH

ON

E

(2

) 2

-0

Ea st H az el

A ve nu e, S ui te

1, C oe ur d 'A le ne

, I da ho

Record Drawings (1/14/2025)

1/8" = 1'-0"

FA-1.1

Scale: 1/8'' = 1'-0''

20 4 8 16 32

Second Floor - Fire Alarm System Plan

AutoCAD SHX Text

EXIT

AutoCAD SHX Text

EXIT

A operate. For help, please refer to riser diagram for reference.

* Do not route conduit into the bottom of any fire alarm system component cabinets.

* After each duct smoke detector has been installed use a Megnehelic

Test Instrument to verify adequate air flow, show the results on the Shop Drawings for the AHJ's review.

* Tap all speakers at 1/2 watt - 25 volts unless otherwise indicated at individual device.

* Contractor may reuse existing pathways where available. Verify with system designer prior to adding additional devices or extending circuits to ensure voltage drop calculations are within acceptable limits.

* Building is known to contain asbestos. Contractor shall comply with asbestos abatement procedures identified in Project Specification section 028211 "Traditional Asbestos Abatement".

1) Section of NFPA 72, National Fire Alarm Code requires units to be provided with smoke detection in areas that are not continuously occupied.

2) Provide Dedicated 120VAC circuit to the FACP label the Dedicated circuit breaker "Fire Alarm." In red with lockout. Location of breaker shall be noted at FACP.

3) Fiber Network routing to be field coordinated.

4) Detector is to activate Elevator Recall Functions.

5) Detector is to activate Elevator Shunt Trip. Mount within 24" of Sprinkler

Head.

6) Not Used.

7) Detector is to activate Door Release Service (Magnetic Door Hold Opens).

8) Smoke detection omitted in areas where not required by Code or VA Fire

Protection Manual.

9) Attic Level notification devices to be mounted on horizontal beams.

Reuse existing pathways and mounting fixtures where possible.

Flag Notes: (Some flag notes may not appear on every sheet)

Addressing Legend:

D = Detector M = Module

Module/Device Number M01L01

Loop Number N01Node Number

ATTIC AREA

ATTIC AREA

F F

S115C 1W

S135 1W

S135 1W

S115C 1W

To

FACP

To

RPS#1

S1-5 V0-6

S1-5 V0-6

S1-5 V0-6

S1-5 V0-6

N22:L1:M012

N22:L1:M013

J J

J

J

Home Run through 2nd Floor

SV

S,V

S,V

A A

Number of Sheets:

By

Installing Fire Alarm System Contractor:

Date

Drawn By:

Drawn Date:

Scale:

Drawing No.

Revisions Description

Authority Having Jurisdiction:

Project Contacts

DHL

04/22/2024

VA

W al la

W al la

B ui ld in g

W ai nw rig ht

D riv e W al la

W al la , W

A

Li fe

S af et y

(F ire

A la rm S ys te m ) D ra w in gs

COPYRIGHT NOTICE

ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN

CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF

VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED

OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF

VULCAN FIRE

Reviewed by:

ENGINEERED SYSTEM DISTRIBUTION

by Honeywell

TM

Vulcan Project #: FI23-013

Signature:____________________________

U .S

.D ep ar tm en t o f V et er an s A ffa irs

Fi re

A la rm S ys te m R ep la ce m en t -

P ha se B

Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362

(509) 524-4603

Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814

(208) 277-0171

GC

L ice ns e:

V

UL

CA

F*

0M

El ec

L ice ns e:

V

UL

CA

F*

W

EB

SI

TE

: w w w

.v ul ca nf ire us

.c om

PH

ON

E

(2

) 2

-0

Ea st H az el

A ve nu e, S ui te

1, C oe ur d 'A le ne

, I da ho

Record Drawings (1/14/2025)

1/8" = 1'-0"

FA-1.1

Scale: 1/8'' = 1'-0''

20 4 8 16 32

Attic - Fire Alarm System Plan

AutoCAD SHX Text

EXIT

EXIT

Basement Basement

Second Level

Dedicated

120VAC

SS

FACP

FARC

MAP

GUTTER

CPU2-640

HS-NCM-SF

NCA-2

DAA2-7525

DVC / CMIC-1

EVAC

BATT

Battery Battery

B300-6

From

Device SLC Loop previous

Device SLC Loop To next

A

A

Addressable Smoke or Heat Detector

RA

Security System Unlock Doors

RPS

#1

Battery Battery

Elevator Controls #1

120VAC Shunt Trip Power Source

Primary Recall (Steady) Alternate Recall (Steady)

Shunt Trip Breaker

Fire Light Indicator (Flashing)

R

FATCXP6-R

Sp ar e Sp ar e

47k

47k

T1

T2

T4 T5

LOOP

T6 T7 T8

T9 T10

ADDRESS

T3

T11

RPS Monitored by a FMM-1 Monitor Module

FMM-1

Remote Power Supply (Trouble)

D 0 15 14

6 7 8 9 9876

1 0

TENS ONES

A

A

1W S75C

4.7k

20k

Speaker/Strobe

Speaker

Strobe

VV

S S

Strobe

Strobe

S_ S_

R

First Level First Level

Second Level

Backflow Preventer

VS

47k

Main - Fire Sprinkler System

WF 47k

VS

Main

PS

PS

LA

WF

47k

47k -

T1

T2

T4 T5

LOOP

T6 T7 T8

T9 T10

ADDRESS

T3

T11

FMM-1

Fire Sprinkler Valve Tamper

D 0 15 14

6 7 8 9 9876

1 0

TENS ONES

A

A

Fire Sprinkler System - Valve Tamper with FMM-1 Monitor Module

WF

VS

47k

47k

AIM

AIM

AIM

AIM

AIM

AIM

AIM

AOM

R

Attic Level Attic Level

F

AIM

F

SBB-D4

DR-D4

4.7k

4.7k

PPP PP

SSS SS

F135° H

F135° H

P S

P S

AOM

R

120VAC

R

DH F F FF

AOM

R

120VAC

R

DH

15 S15C S30C 1W

S15C 1W

S75C 1W

S15C

1W S15C 15 15

4.7k

(E)

(E)

1W S15C

1W S75C

1W S135

1W S75C 15

1W S15C

1W S75C

(N) (H)12

0V

AC

PR-1

Magnetic Door Hold Opens

0 15

6 7 8 9 9876

1 0

T1

T2

T4 T5

LOOP

T6 T7 T8

T9 T10

TENS ONES

ADDRESS

T3

T11

FRM-1

A

A

Magnetic Doors with PR-1 Relay Controlled by FRM-1 Control Relay Module

YE

LL

OW

NC

BL

UE

C

OR

AN

GE

NO

P

PP

PP

S

SS

SS

PP

SS

P S

P S

P S

P S

P S

P S

P S

FFF

AOM

R

120VAC

R

DH

(E)

AOM

R

120VAC

R

DH

(E)

AOM

R

120VAC

R

DH

(E)

AOM

R

120VAC

R

DHDH

(E) (E)

AOM

R

120VAC

R

DHDH

(E) (E)

1W S15C

1W S75C15

1W S135

1W S75C 15

1W S15C

1W S15C

20k

4.7k

4.7k

AOM

R

120VAC

R

DH

(E)

AOM

R

120VAC

R

DH

(E)

AOM

R

120VAC

R

DHDH

(E) (E)

AOM

R

120VAC

R

DHDH

(E) (E)

F

PP

SS

PP

SS

P

S P

S P

S P

S P

S

Addressable Pull Station

321(-)

A ANBG-12LX

1W S115C

1W S135

1W S135

1W S115C

4.7k

20k

To Fiber Network Bldg. 48

To Fiber Network Bldg. 69

1W

S15C WP

15C 15S15C 1W

S75C 1W

S75C S30C 1W

S30C

1W S75C S75C

1W S30C S15C

1W S15C

1W S75C

1W S75C

1W S75C

1W S75C

WP

15C

C S

WP

15C

S15C 1W

S75C S15C 1W

S75C 1W

S15C 1W

S15C WP

15C

C S

1W

S15C

20k

F

AOM

R

120VAC

R

DH

(E)

AOM

R

120VAC

R

DH

(E)

PP

SS

AOM

R

120VAC

R

DH

(E)

1W S75C

1W S15C

20k

1W

S75C 1W

S75C

F135° H F

DH

(E)

20k

EP

Strobe S0-2

Speaker V0-2 V

S

SL

C

Lo op

A

A

Dedicated

120VAC

EP

Strobe S0-3 S

Strobe S1-3

Speaker V0-4 V

S

Strobe S1-4 S

D

D

A

V V

S

Speaker V0-3 V

D

D

D

D

D

D

D

A

Strobe S1-5 S

S

S

S S

S

Strobe S1-1

Speaker V0-1 V

S

Sy nc

C kt

X

0-

X

X

Strobe S1-2 S

V

V

A

A

A

A

A

A

SL

C

Lo op

V

A

A

A

A

A

A

A

A

A

A

SL

C

Lo op

A

F

F

S

A

V

Speaker V0-6 V

Speaker V0-5 V

A

A

A

Number of Sheets:

By

Installing Fire Alarm System Contractor:

Date

Drawn By:

Drawn Date:

Scale:

Drawing No.

Revisions Description

Authority Having Jurisdiction:

Project Contacts

DHL

04/22/2024

VA

W al la

W al la

B ui ld in g

W ai nw rig ht

D riv e W al la

W al la , W

A

Li fe

S af et y

(F ire

A la rm S ys te m ) D ra w in gs

COPYRIGHT NOTICE

ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN

CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF

VULCAN FIRE, AND THE SAME MAY NOT BE DUPLICATED, USED

OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF

VULCAN FIRE

Reviewed by:

ENGINEERED SYSTEM DISTRIBUTION

by Honeywell

TM

Vulcan Project #: FI23-013

Signature:____________________________

U .S

.D ep ar tm en t o f V et er an s A ffa irs

Fi re

A la rm S ys te m R ep la ce m en t -

P ha se B

Walla Walla Fire Department 2251 S. Howard St., Walla Walla, WA 99362

(509) 524-4603

Vulcan Fire 112 East Hazel Ave., Ste#1, Coeur d'Alene, ID 83814

(208) 277-0171

GC

L ice ns e:

V

UL

CA

F*

0M

El ec

L ice ns e:

V

UL

CA

F*

W

EB

SI

TE

: w w w

.v ul ca nf ire us

.c om

PH

ON

E

(2

) 2

-0

Ea st H az el

A ve nu e, S ui te

1, C oe ur d 'A le ne

, I da ho

Record Drawings (1/14/2025)

N/A

FA-2.1Riser Diagram / Details - Fire Alarm System

VOLTAGE DROPS ARE CALCULATED AT 16VDC.

L= ONE WAY LENGTH OF CIRCUIT(FEET)

WHERE VD= VOLTAGE DROP

R= 3.19 OHMS PER THOUSAND

I= LOAD CURRENT(AMPERES)

AFTER DETERMINING THE LENGTH OF THE HORN/STROBE CIRCUIT, USE

THE FOLLOWING FORMULA TO CALCULATE THE VOLTAGE DROP.

2xLxRxI

VD=

LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD

ALLOWS FOR A SMALL MARGIN OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL

CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN ON THE SHOP SUBMITTAL

DRAWINGS. IF ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE

CIRCUIT LENGTH, CONTACT VULCAN FIRE.

VOLTAGE-DROP CALCULATION NOTE:

** STARTING VOLTAGE-DROP CALCULATIONS IS 20.4 PER UL 864, 9TH EDITION STANDARDS FOR FIRE ALARM

CONTROL PANELS.

AutoCAD SHX Text 47k

AutoCAD SHX Text

EOL

AutoCAD SHX Text Resistor

AutoCAD SHX Text 47k

AutoCAD SHX Text

EOL

Resistor

Sheets and Views
FI23-013 VA Walla Walla Bldg-68 _Record-FA-0.0 (1)
FI23-013 VA Walla Walla Bldg-68 _Record-FA-1.1 (2)
FI23-013 VA Walla Walla Bldg-68 _Record-FA-1.2 (3)
FI23-013 VA Walla Walla Bldg-68 _Record-FA-1.3 (4)
FI23-013 VA Walla Walla Bldg-68 _Record-FA-1.4 (5)
FI23-013 VA Walla Walla Bldg-68 _Record-FA-2.1 (6)

File details come from the government source that posted it. Updated .