Prime
| Name of Prime Contractor | Prime | Reference 1 | Reference 2 | Reference 3 | Reference 4 | Reference 5 | ||
| TECHNICAL CAPABILITIES | ||||||||
| Mechanical | ||||||||
| M1 | Air duct, expansion joints, and control/process valves (≥ 36” Ø and 150 psig) | |||||||
| M2 | High pressure duct/piping & valves (typ. 4" to 8"Ø, ≥ 4000 psig) | |||||||
| M3 | Large pressure vessels (≥ 2000 psig; ≥ 10K gallons) | |||||||
| M4 | Desiccant bed air dryers (≤ 300 psia & ≥ 200 lb/s) | |||||||
| M5 | Turning vanes for large air ducting (up to 50-ft Ø; 0.5-160 psia) | |||||||
| M6 | Cooling water/raw water pumps (300-50,000 gpm; 30-4,000 hp), filters/strainers, control/process valves,and distribution lines (typ. 6” to 90” Ø) | |||||||
| M7 | Hydraulic systems with high flow and pressure requirements (20-200 gpm (typ. 2 pumps @ 100 gpm ea) and 2500 psig) | |||||||
| M8 | Large steam distribution systems (60 kpph boilers, and piping up to 14 inches diameter) | |||||||
| M9 | Chillers and refrigeration equipment (300-5000 refrigeration tons) | |||||||
| M10 | Large heat exchangers: air to air; water to air; shell and tube, etc. (∆T up to 325 °F) | |||||||
| Electrical | ||||||||
| E1 | Interior & exterior lighting for industrial buildings | |||||||
| E2 | Medium voltage gas insulated switchgear (≤ 13.8 kV) | |||||||
| E3 | Unit Substations (typical 6.9/2.4kV) | |||||||
| E4 | Motor Control Centers (≤ 600V) | |||||||
| E5 | Transformers (≤ 161/13.8kV) | |||||||
| E6 | Uninterruptable Power Supply (UPS) | |||||||
| E7 | Ducting/vaults/ cables (13.8 & 6.9 kV) | |||||||
| E8 | Motor Exciters | |||||||
| E9 | Oil Circuit Breakers (typical 3000 amp & 550kV BIL) | |||||||
| E10 | Power panels/conduit/wiring (≤ 480V) | |||||||
| E11 | Variable frequency drives for motors (≥ 600V & ≤ 69kV) | |||||||
| ID&C | ||||||||
| I1 | PLC-based industrial control systems | |||||||
| I2 | High Speed (< 10ms Loop Time) Facility Control Systems | |||||||
| I3 | Controls software development and modification | |||||||
| I4 | Secure Control Systems | |||||||
| I5 | Data logging system design and integration | |||||||
| I6 | Control Systems Instrumentation design and integration | |||||||
| MANAGEMENT SUBFACTOR | ||||||||
| M-2.2.1.1.1.1.1. | Qualified Personnel | |||||||
| M-2.2.1.1.1.1.2. | Resource Capacity | |||||||
| M-2.2.1.1.1.1.3. | Teaming | |||||||
| M-2.2.1.1.1.1.4. | Integrated Scheduling | |||||||
| M-2.2.1.1.1.1.5. | Quality Assuarnce | |||||||
| M-2.2.1.1.1.1.6. | Subcontracting Management |
&"Times New Roman,Regular"ATTACHMENT L-6 RELEVANCY MATRIX &"Times New Roman,Regular"FARM
FA9101-16-R-0100
Attachment 8
Partners
| Name of Partner (Subcontractor / JV) | Prime | Reference 1 | Reference 2 | Reference 3 | ||
| TECHNICAL CAPABILITIES | ||||||
| Mechanical | ||||||
| M1 | Air duct, expansion joints, and control/process valves (≥ 36” Ø and 150 psig) | |||||
| M2 | High pressure duct/piping & valves (typ. 4" to 8"Ø, ≥ 4000 psig) | |||||
| M3 | Large pressure vessels (≥ 2000 psig; ≥ 10K gallons) | |||||
| M4 | Desiccant bed air dryers (≤ 300 psia & ≥ 200 lb/s) | |||||
| M5 | Turning vanes for large air ducting (up to 50-ft Ø; 0.5-160 psia) | |||||
| M6 | Cooling water/raw water pumps (300-50,000 gpm; 30-4,000 hp), filters/strainers, control/process valves,and distribution lines (typ. 6” to 90” Ø) | |||||
| M7 | Hydraulic systems with high flow and pressure requirements (20-200 gpm (typ. 2 pumps @ 100 gpm ea) and 2500 psig) | |||||
| M8 | Large steam distribution systems (60 kpph boilers, and piping up to 14 inches diameter) | |||||
| M9 | Chillers and refrigeration equipment (300-5000 refrigeration tons) | |||||
| M10 | Large heat exchangers: air to air; water to air; shell and tube, etc. (∆T up to 325 °F) | |||||
| Electrical | ||||||
| E1 | Interior & exterior lighting for industrial buildings | |||||
| E2 | Medium voltage gas insulated switchgear (≤ 13.8 kV) | |||||
| E3 | Unit Substations (typical 6.9/2.4kV) | |||||
| E4 | Motor Control Centers (≤ 600V) | |||||
| E5 | Transformers (≤ 161/13.8kV) | |||||
| E6 | Uninterruptable Power Supply (UPS) | |||||
| E7 | Ducting/vaults/ cables (13.8 & 6.9 kV) | |||||
| E8 | Motor Exciters | |||||
| E9 | Oil Circuit Breakers (typical 3000 amp & 550kV BIL) | |||||
| E10 | Power panels/conduit/wiring (≤ 480V) | |||||
| E11 | Variable frequency drives for motors (≥ 600V & ≤ 69kV) | |||||
| ID&C | ||||||
| I1 | PLC-based industrial control systems | |||||
| I2 | High Speed (< 10ms Loop Time) Facility Control Systems | |||||
| I3 | Controls software development and modification | |||||
| I4 | Secure Control Systems | |||||
| I5 | Data logging system design and integration | |||||
| I6 | Control Systems Instrumentation design and integration | |||||
| MANAGEMENT SUBFACTOR | ||||||
| M-2.2.1.1.1.1.1. | Qualified Personnel | |||||
| M-2.2.1.1.1.1.2. | Resource Capacity | |||||
| M-2.2.1.1.1.1.3. | Teaming | |||||
| M-2.2.1.1.1.1.4. | Integrated Scheduling | |||||
| M-2.2.1.1.1.1.5. | Quality Assuarnce | |||||
| M-2.2.1.1.1.1.6. | Subcontracting Management |