CAPSOL-EXP-LEDM-Text-Display-Data-Sheet-V1.4.pdf_safe.pdf

PDF 168 KB Posted

Attached to
TINKER AFB MAC BOA WWYK190068 REPAIR FIRE SUPPRESSION SYSTEM, B2280
Solicitation number
FA813725R0035
Issued by

About this file

This technical data sheet details the CAPSOL CC-EXP-LEDM Explosion Proof LED Text Display, a specialized notification system designed for hazardous environments. The device features a 1.2" dual-line LED display with a 22 7/8" x 22 7/8" x 10.5" deep NEMA7 enclosure, rated for use in Class I, II, and III hazardous locations including aircraft hangars, fuel cells, ammunition and chemical plants. It can be powered by PoE (42.5-57VDC) or 24 VDC, with power consumption ranging from 6-40W depending on operational state, and includes features like LED strobe lights, audio outputs, and configurable control relays and inputs.

The system requires a CC-LEDController to initiate messages and is compatible with the CAPSOLControl operating system, which provides additional messaging capabilities. Operating specifications include a temperature range of -14° to 122°F, 95% humidity tolerance, and communication options including PoE, LAN, and RS232/RS485 interfaces. The display is designed and assembled in America using both US and imported parts, with a shipping weight of 180 lbs and capabilities for early threat notification and data processing across various hazardous industrial environments.

View the file

Other files

File Type Posted
Solicitation Amendment FA813725R00350009 SF 30.pdf PDF
Solicitation Amendment FA813725R00350007 SF 30.pdf PDF
Solicitation Amendment FA813725R00350006 SF 30.pdf PDF
GOVERNMENT RESPONSE TO RFI 25_25A COR.pdf PDF
WWYK190068_RFI_23-24-25 SEP24.pdf PDF
CAPSOL-LEDM-Text-Display-Data-Sheet_1.6.pdf PDF
RFI 26 Fixture with Joist.pdf PDF
RFI 26 WWYK190068_Rev_1_26 51 00.pdf PDF
Solicitation Amendment FA813725R00350005 SF 30.pdf PDF
190068_Attch04_Revised_Design_Analysis.pdf PDF
190068_Attch01_DRWG.pdf PDF
Solicitation Amendment FA813725R00350003 SF 30.pdf PDF
190068_IFC_Design Analysis_Final.pdf PDF
190068_DD100_Appendix A.pdf PDF
FP from DACA63-76-C-0111.pdf PDF
EMS General Awareness Training for Contractors Aug 2018 PDF.pdf PDF
00 70 00.pdf PDF
tinkerafb_INRMP.pdf PDF
dafman91-203.pdf PDF
ufc_3_260_04_2018.pdf PDF
afi91-202_afmcsup.pdf PDF
ufc_3_601_02_2021.pdf PDF
dafi91-202.pdf PDF
tinkerafbi21-100.pdf PDF
tinkerafb_INRMP_App E.pdf PDF
017800_Attch1_DD1354.pdf PDF
00 72 00.pdf PDF
00 71 00.pdf PDF
01 78 00.pdf PDF
01 45 00.00 10.pdf PDF
01 78 23.pdf PDF
000_TABLE OF CONTENTS.pdf PDF
ERDCITL_TR12-6_r6.pdf PDF
ufc_3_600_01_2016_c6.pdf PDF
tinkerafbi13-204.pdf PDF
afman32-7003.pdf PDF
tinkerafb_HWMP.pdf PDF
Recovered Materials Determination Form.pdf PDF
013300_Attch1_TAFBF3000.pdf PDF
007200_Attch7a_AF3952.pdf PDF
Solicitation - FA813725R0035 for WWYK190068.pdf PDF
01 33 00.pdf PDF
00 80 05.pdf PDF
01 32 16.00 20.pdf PDF
00 80 00.pdf PDF
WWYK190068 Canceled SiteVisit Signin 12JUN25.pdf PDF
190068_ATT10_Submittal_Register.pdf PDF
190068_ATT9_SOW.pdf PDF
EAL List - 190068.xlsx XLSX spreadsheet
190068_ATT11_Revised_Drawings.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CAPSOL Explosion Proof LED Text Display Specifications

CAPSOL’s EXP-LEDM Explosion Proof LED Display is perfect providing visible notification for hazardous areas. The 1.2’ letter height provides exceptional visibility in an alarm condition in all locations.

An excellent choice for aircraft hangars, fuel cells, ammunition plants, chemical plants and other hazardous environments, the Enclosure is UL Classified for use in Class I, Div 1&2 Groups B,C,D. Class II, Div 1&2 Groups E,F,G and Class III. Rated for NEMA 4/7/9 applications

WHO WE ARE: Since 2013, we have been developing systems to identify potential threats and provide early notification. The CAPSOLSuite is designed to gather, identify, and process data as early as possible to mitigate a threat. Notifying all affected people quickly and clearly makes lives safer.

19939 W. 162ND ST, OLATHE, KS 66062

913-203-1110 : WWW.CAPSOL.ORG

CC-EXP-LEDM LED Text Display Technical Data Sheet

POWER INPUT Powered by PoE (42.5-57VDC) Powered by 24 VDC Wattage Wattage Booting Up (intermittent duty, MAX) 40W/1A 32W/1.4A Alert in Progress 24W/.6A 20W/.9A Standby (with Time Display in Green) 7.5W/.2A 6W/.25A LED Strobe Light Intensity * 135CD 135CD Rated Sound Output 2W/1m 2W/1m Audio Output Non-Amplified Non-Amplified Sounds** 86+- 3dB - Event Alarm, End of Alert Sound, and System Test Announcement

*LED Intensity Per Side. LED Strobe Lights can be disabled in programming and are non-syncable. Strobes lights flash for approximately 5 seconds when activated using the CC-LEDControl-SA.

Length of strobe light activation is programable in the CAPSOLControl operating system interfaced with CC-LEDControl-WKS.

**Can be disabled when using CC-LEDControl-SA. Programmable in CC-LEDControl interfaced with CC-LEDControl-WKS.

*** When using RS232 or RS485 for communication, some features may not be available.

Communications PoE IEEE802. 3bt. 42.5 - 57vdc Type A (4,5 + / 7, 8 -) Type B (1,2 + / 3, 6 -) LAN 10/100/1000 Network Connectivity RS232 9600Bps/ RS485*** The CC-EXP-LEDM Display requires the use of CC-LEDController to initiate messages.

The CAPSOLControl operating system provides additional messaging capability as well as access to relays and inputs.

Mechanical and Environmental Overall Size 22 7/8” x 22 7/8” x 10 ½” Deep Shipping Weight 180 lbs.

Operating Temperature -14° to 122°F (-10° to 50°C) Humidity 95% RH, non-condensing at 92°F (33°C).

Conformal coating NEMA7 Enclosure Control Relays 2 – (Configurable with CAPSOLControl WKS) Inputs – 4 (Configurable with CAPSOLControl WKS) Connections - Terminal block for 18 AWG to 12 AWG Letter Height 1.2” dual line during a message

Designed and assembled in America with US and imported parts.

EXP- LEDM V1.1

File details come from the government source that posted it. Updated .